CVE-2024-11425 (GCVE-0-2024-11425)
Vulnerability from cvelistv5 – Published: 2025-01-17 09:00 – Updated: 2025-02-12 17:09- CWE-131 - Incorrect Calculation of Buffer Size
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety) |
Affected:
Versions prior to SV4.30
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-11425",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-17T13:22:26.095314Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T17:09:38.349Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to SV4.30"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to SV4.21"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BMENOR2200H",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EVLink Pro AC",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v1.3.10"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the\nproduct when an unauthenticated user is sending a crafted HTTPS packet to the webserver.\n\n\u003cbr\u003e"
}
],
"value": "CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the\nproduct when an unauthenticated user is sending a crafted HTTPS packet to the webserver."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-131",
"description": "CWE-131 Incorrect Calculation of Buffer Size",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-17T09:00:32.335Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-11425",
"datePublished": "2025-01-17T09:00:32.335Z",
"dateReserved": "2024-11-19T15:35:20.847Z",
"dateUpdated": "2025-02-12T17:09:38.349Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2024-11425\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2025-01-17T09:15:07.613\",\"lastModified\":\"2025-01-17T09:15:07.613\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the\\nproduct when an unauthenticated user is sending a crafted HTTPS packet to the webserver.\"},{\"lang\":\"es\",\"value\":\"CWE-131: Existe una vulnerabilidad de c\u00e1lculo incorrecto del tama\u00f1o del b\u00fafer que podr\u00eda provocar una denegaci\u00f3n de servicio del producto cuando un usuario no autenticado env\u00eda un paquete HTTPS manipulado espec\u00edficamente al servidor web.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-131\"}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-01.pdf\",\"source\":\"cybersecurity@se.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-11425\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-17T13:22:26.095314Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-12T17:09:06.465Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.7, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety)\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions prior to SV4.30\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions prior to SV4.21\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"BMENOR2200H\", \"versions\": [{\"status\": \"affected\", \"version\": \"All Versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"EVLink Pro AC\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions prior to v1.3.10\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-01.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the\\nproduct when an unauthenticated user is sending a crafted HTTPS packet to the webserver.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the\\nproduct when an unauthenticated user is sending a crafted HTTPS packet to the webserver.\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-131\", \"description\": \"CWE-131 Incorrect Calculation of Buffer Size\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2025-01-17T09:00:32.335Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-11425\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-12T17:09:38.349Z\", \"dateReserved\": \"2024-11-19T15:35:20.847Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2025-01-17T09:00:32.335Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
CERTFR-2025-AVI-0034
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire, une élévation de privilèges et un déni de service à distance.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | BMXNOE0110 toutes versions pour la vulnérabilité CVE-2024-12142 | ||
| Schneider Electric | N/A | Modicon M580/Quantum communication modules BMXCRA BMXCRA31200 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | EcoStruxureTM Control Expert Asset Link versions antérieures à 4.0 SP1 pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon Quantum communication modules 140CRA 140CRA31200 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | Modicon M340 processors (part numbers BMXP34*) toutes versions pour la vulnérabilité CVE-2024-12142 | ||
| Schneider Electric | N/A | EcoStruxureTM Machine SCADA Expert Asset Link toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Pro-face GP-Pro EX toutes versions pour la vulnérabilité CVE-2024-12399 | ||
| Schneider Electric | N/A | BMENOR2200H toutes versions pour la vulnérabilité CVE-2024-11425 | ||
| Schneider Electric | N/A | EcoStruxure OPC UA Server Expert toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | EcoStruxureTM Process Expert toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Pro-face Remote HMI toutes versions pour la vulnérabilité CVE-2024-12399 | ||
| Schneider Electric | N/A | EcoStruxureTM Control Expert versions antérieures à 16.1 | ||
| Schneider Electric | N/A | EcoStruxure Machine Expert including EcoStruxureTM Machine Expert Safety toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | EVLink Pro AC versions antérieures à 1.3.10 | ||
| Schneider Electric | N/A | Modicon M580 CPU (part numbers BMEP* et BMEH*, excluding M580 CPU Safety) versions antérieures à 4.30 pour la vulnérabilité CVE-2024-11425 | ||
| Schneider Electric | N/A | EcoStruxure Machine Expert Twin toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | BMXNOR0200H versions antérieures à 1.70IR26 | ||
| Schneider Electric | N/A | EcoStruxure Operator Terminal Expert toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon M580/Quantum communication modules BMXCRA BMXCRA31210 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | BMXNOE0100 toutes versions pour la vulnérabilité CVE-2024-12142 | ||
| Schneider Electric | N/A | Vijeo Designer toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon M580 CPU Safety (part numbers BMEP58*S et BMEH58*S) versions antérieures à 4.21 pour la vulnérabilité CVE-2024-11425 | ||
| Schneider Electric | N/A | Zelio Soft 2 toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon M580 communication modules BMENOC BMENOC0321 versions antérieures à 1.10 | ||
| Schneider Electric | N/A | EcoStruxure Architecture Builder versions antérieures à 7.0.18 | ||
| Schneider Electric | N/A | Modicon Quantum communication modules 140CRA 140CRA31908 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | Modicon M580 communication modules BMECRA BMECRA31210 toutes versions pour la vulnérabilité CVE-2021-29999 |
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "BMXNOE0110 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12142",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580/Quantum communication modules BMXCRA BMXCRA31200 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Control Expert Asset Link versions ant\u00e9rieures \u00e0 4.0 SP1 pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum communication modules 140CRA 140CRA31200 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 processors (part numbers BMXP34*) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12142",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Machine SCADA Expert Asset Link toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face GP-Pro EX toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12399",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMENOR2200H toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-11425",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure OPC UA Server Expert toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Process Expert toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face Remote HMI toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12399",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Control Expert versions ant\u00e9rieures \u00e0 16.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Machine Expert including EcoStruxureTM Machine Expert Safety toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EVLink Pro AC versions ant\u00e9rieures \u00e0 1.3.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 CPU (part numbers BMEP* et BMEH*, excluding M580 CPU Safety) versions ant\u00e9rieures \u00e0 4.30 pour la vuln\u00e9rabilit\u00e9 CVE-2024-11425",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Machine Expert Twin toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMXNOR0200H versions ant\u00e9rieures \u00e0 1.70IR26",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Operator Terminal Expert toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580/Quantum communication modules BMXCRA BMXCRA31210 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMXNOE0100 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12142",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Vijeo Designer toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 CPU Safety (part numbers BMEP58*S et BMEH58*S) versions ant\u00e9rieures \u00e0 4.21 pour la vuln\u00e9rabilit\u00e9 CVE-2024-11425",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Zelio Soft 2 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 communication modules BMENOC BMENOC0321 versions ant\u00e9rieures \u00e0 1.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Architecture Builder versions ant\u00e9rieures \u00e0 7.0.18",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum communication modules 140CRA 140CRA31908 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 communication modules BMECRA BMECRA31210 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2024-12399",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12399"
},
{
"name": "CVE-2024-11139",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-11139"
},
{
"name": "CVE-2021-29999",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29999"
},
{
"name": "CVE-2024-11425",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-11425"
},
{
"name": "CVE-2024-2658",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-2658"
},
{
"name": "CVE-2024-12142",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12142"
}
],
"links": [],
"reference": "CERTFR-2025-AVI-0034",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2025-01-15T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire, une \u00e9l\u00e9vation de privil\u00e8ges et un d\u00e9ni de service \u00e0 distance.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-01",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-01.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-02",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-09",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-09\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-09.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-03",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-03.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-07",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-07\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-07.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-05",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-05.pdf"
}
]
}
CERTFR-2025-AVI-0034
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire, une élévation de privilèges et un déni de service à distance.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | BMXNOE0110 toutes versions pour la vulnérabilité CVE-2024-12142 | ||
| Schneider Electric | N/A | Modicon M580/Quantum communication modules BMXCRA BMXCRA31200 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | EcoStruxureTM Control Expert Asset Link versions antérieures à 4.0 SP1 pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon Quantum communication modules 140CRA 140CRA31200 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | Modicon M340 processors (part numbers BMXP34*) toutes versions pour la vulnérabilité CVE-2024-12142 | ||
| Schneider Electric | N/A | EcoStruxureTM Machine SCADA Expert Asset Link toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Pro-face GP-Pro EX toutes versions pour la vulnérabilité CVE-2024-12399 | ||
| Schneider Electric | N/A | BMENOR2200H toutes versions pour la vulnérabilité CVE-2024-11425 | ||
| Schneider Electric | N/A | EcoStruxure OPC UA Server Expert toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | EcoStruxureTM Process Expert toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Pro-face Remote HMI toutes versions pour la vulnérabilité CVE-2024-12399 | ||
| Schneider Electric | N/A | EcoStruxureTM Control Expert versions antérieures à 16.1 | ||
| Schneider Electric | N/A | EcoStruxure Machine Expert including EcoStruxureTM Machine Expert Safety toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | EVLink Pro AC versions antérieures à 1.3.10 | ||
| Schneider Electric | N/A | Modicon M580 CPU (part numbers BMEP* et BMEH*, excluding M580 CPU Safety) versions antérieures à 4.30 pour la vulnérabilité CVE-2024-11425 | ||
| Schneider Electric | N/A | EcoStruxure Machine Expert Twin toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | BMXNOR0200H versions antérieures à 1.70IR26 | ||
| Schneider Electric | N/A | EcoStruxure Operator Terminal Expert toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon M580/Quantum communication modules BMXCRA BMXCRA31210 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | BMXNOE0100 toutes versions pour la vulnérabilité CVE-2024-12142 | ||
| Schneider Electric | N/A | Vijeo Designer toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon M580 CPU Safety (part numbers BMEP58*S et BMEH58*S) versions antérieures à 4.21 pour la vulnérabilité CVE-2024-11425 | ||
| Schneider Electric | N/A | Zelio Soft 2 toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon M580 communication modules BMENOC BMENOC0321 versions antérieures à 1.10 | ||
| Schneider Electric | N/A | EcoStruxure Architecture Builder versions antérieures à 7.0.18 | ||
| Schneider Electric | N/A | Modicon Quantum communication modules 140CRA 140CRA31908 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | Modicon M580 communication modules BMECRA BMECRA31210 toutes versions pour la vulnérabilité CVE-2021-29999 |
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "BMXNOE0110 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12142",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580/Quantum communication modules BMXCRA BMXCRA31200 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Control Expert Asset Link versions ant\u00e9rieures \u00e0 4.0 SP1 pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum communication modules 140CRA 140CRA31200 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 processors (part numbers BMXP34*) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12142",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Machine SCADA Expert Asset Link toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face GP-Pro EX toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12399",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMENOR2200H toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-11425",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure OPC UA Server Expert toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Process Expert toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face Remote HMI toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12399",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Control Expert versions ant\u00e9rieures \u00e0 16.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Machine Expert including EcoStruxureTM Machine Expert Safety toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EVLink Pro AC versions ant\u00e9rieures \u00e0 1.3.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 CPU (part numbers BMEP* et BMEH*, excluding M580 CPU Safety) versions ant\u00e9rieures \u00e0 4.30 pour la vuln\u00e9rabilit\u00e9 CVE-2024-11425",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Machine Expert Twin toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMXNOR0200H versions ant\u00e9rieures \u00e0 1.70IR26",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Operator Terminal Expert toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580/Quantum communication modules BMXCRA BMXCRA31210 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMXNOE0100 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12142",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Vijeo Designer toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 CPU Safety (part numbers BMEP58*S et BMEH58*S) versions ant\u00e9rieures \u00e0 4.21 pour la vuln\u00e9rabilit\u00e9 CVE-2024-11425",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Zelio Soft 2 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 communication modules BMENOC BMENOC0321 versions ant\u00e9rieures \u00e0 1.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Architecture Builder versions ant\u00e9rieures \u00e0 7.0.18",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum communication modules 140CRA 140CRA31908 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 communication modules BMECRA BMECRA31210 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2024-12399",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12399"
},
{
"name": "CVE-2024-11139",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-11139"
},
{
"name": "CVE-2021-29999",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29999"
},
{
"name": "CVE-2024-11425",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-11425"
},
{
"name": "CVE-2024-2658",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-2658"
},
{
"name": "CVE-2024-12142",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12142"
}
],
"links": [],
"reference": "CERTFR-2025-AVI-0034",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2025-01-15T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire, une \u00e9l\u00e9vation de privil\u00e8ges et un d\u00e9ni de service \u00e0 distance.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-01",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-01.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-02",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-09",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-09\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-09.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-03",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-03.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-07",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-07\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-07.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-05",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-05.pdf"
}
]
}
CVE-2024-11425
Vulnerability from fstec - Published: 19.11.2024{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"CVSS 4.0": "AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Schneider Electric",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "- (BMENOR2200H), \u0434\u043e SV4.30 (Modicon M580 CPU BMEH), \u0434\u043e SV4.30 (Modicon M580 CPU BMEP), \u0434\u043e SV4.21 (Modicon M580 CPU Safety), \u0434\u043e 1.3.10 (EVLink Pro AC)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439:\nhttps://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-01.pdf\n\n\u041a\u043e\u043c\u043f\u0435\u043d\u0441\u0438\u0440\u0443\u044e\u0449\u0438\u0435 \u043c\u0435\u0440\u044b:\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432 \u043c\u0435\u0436\u0441\u0435\u0442\u0435\u0432\u043e\u0433\u043e \u044d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0443\u0434\u0430\u043b\u0451\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430;\n- \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0435\u0442\u0438 \u0434\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u043c\u0443 \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0443 \u0438\u0437 \u0434\u0440\u0443\u0433\u0438\u0445 \u043f\u043e\u0434\u0441\u0435\u0442\u0435\u0439;\n- \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u0438\u0437 \u0432\u043d\u0435\u0448\u043d\u0438\u0445 \u0441\u0435\u0442\u0435\u0439 (\u0418\u043d\u0442\u0435\u0440\u043d\u0435\u0442);\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u043d\u044b\u0445 \u0441\u0435\u0442\u0435\u0439 \u0434\u043b\u044f \u043e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430 (VPN);\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432 \u043c\u0435\u0436\u0441\u0435\u0442\u0435\u0432\u043e\u0433\u043e \u044d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043a TCP-\u043f\u043e\u0440\u0442\u0443 443;\n- \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0441\u043f\u0438\u0441\u043a\u0430 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u043e\u043c \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0438\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0435\u0439 \u00abModicon M580, Hardware, Reference Manual\u00bb (\u0431\u043e\u043b\u0435\u0435 \u043f\u043e\u0434\u0440\u043e\u0431\u043d\u0430\u044f \u0438\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f \u043e\u043f\u0438\u0441\u0430\u043d\u0430 \u0432 \u0431\u044e\u043b\u043b\u0435\u0442\u0435\u043d\u0435:\nhttps://www.se.com/ww/en/download/document/EIO0000001578/)",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "19.11.2024",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "13.08.2025",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "21.01.2025",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2025-00550",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2024-11425",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "BMENOR2200H, Modicon M580 CPU BMEH, Modicon M580 CPU BMEP, Modicon M580 CPU Safety, EVLink Pro AC",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0438\u0440\u0443\u0435\u043c\u044b\u0445 \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u043b\u0435\u0440\u043e\u0432 Modicon M580 \u0438 \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0437\u0430\u0440\u044f\u0434\u043d\u044b\u0445 \u0441\u0442\u0430\u043d\u0446\u0438\u0439 EVLink Pro AC, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043d\u0435\u043a\u043e\u0440\u0440\u0435\u043a\u0442\u043d\u044b\u043c\u0438 \u0432\u044b\u0447\u0438\u0441\u043b\u0435\u043d\u0438\u044f\u043c\u0438 \u0440\u0430\u0437\u043c\u0435\u0440\u0430 \u0432\u044b\u0434\u0435\u043b\u044f\u0435\u043c\u043e\u0433\u043e \u0431\u0443\u0444\u0435\u0440\u0430, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u0432\u0435\u0440\u043d\u043e\u0435 \u0432\u044b\u0447\u0438\u0441\u043b\u0435\u043d\u0438\u0435 \u0440\u0430\u0437\u043c\u0435\u0440\u0430 \u0431\u0443\u0444\u0435\u0440\u0430 (CWE-131)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0438\u0440\u0443\u0435\u043c\u044b\u0445 \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u043b\u0435\u0440\u043e\u0432 Modicon M580 \u0438 \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0437\u0430\u0440\u044f\u0434\u043d\u044b\u0445 \u0441\u0442\u0430\u043d\u0446\u0438\u0439 EVLink Pro AC \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043d\u0435\u043a\u043e\u0440\u0440\u0435\u043a\u0442\u043d\u044b\u043c\u0438 \u0432\u044b\u0447\u0438\u0441\u043b\u0435\u043d\u0438\u044f\u043c\u0438 \u0440\u0430\u0437\u043c\u0435\u0440\u0430 \u0432\u044b\u0434\u0435\u043b\u044f\u0435\u043c\u043e\u0433\u043e \u0431\u0443\u0444\u0435\u0440\u0430. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438 \u043f\u0443\u0442\u0435\u043c \u043e\u0442\u043f\u0440\u0430\u0432\u043a\u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0441\u0444\u043e\u0440\u043c\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u043f\u0430\u043a\u0435\u0442\u043e\u0432 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u043f\u0440\u043e\u0442\u043e\u043a\u043e\u043b\u0430 HTTPS",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0430\u043c\u0438 \u0434\u0430\u043d\u043d\u044b\u0445",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-01.pdf\nhttps://vuldb.com/?id.292439",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u041e \u0441\u0435\u0442\u0435\u0432\u043e\u0433\u043e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430, \u0421\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f, \u041f\u041e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-131",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,8)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,5)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 4.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 8,7)"
}
CVE-2024-11425
Vulnerability from csaf_se - Published: 2025-01-14 05:00 - Updated: 2025-04-08 04:00Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability in its Modicon M580 PLCs (Programmable Logic Controllers) https://www.se.com/ww/en/product-range/62098-modicon-m580-epac/?parent-subcategory-id=3950\u0026filter=business-1-industrial-automation-and-control#products , \r\nBMENOR2200H https://www.se.com/ww/en/product/BMENOR2200H/modicon-x80-module-coupleur-rtu-%C3%A9volu%C3%A9-sur-ethernet-1-port-s%C3%A9rie-durci/ and EVLink Pro AC https://www.se.com/ww/en/product-range/23107242-evlink-pro-ac/#products products.\r\nModicon M580 PLCs https://www.se.com/ww/en/product-subcategory/3950-pac-programmable-automation-controllers/?filter=business-1-industrial-automation-and-control control and monitor industrial operations.\r\nBMENOR2200H https://www.se.com/ww/en/product/BMENOR2200H/modicon-x80-module-coupleur-rtu-%C3%A9volu%C3%A9-sur-ethernet-1-port-s%C3%A9rie-durci/ is an advanced RTU communication module for Modicon M580 PLCs.\r\nEVLink Pro AC https://www.se.com/ww/en/product-range/23107242-evlink-pro-ac/#products is a 3rd generation of AC charging station.\r\nFailure to apply the fix or mitigations provided below may risk buffer overflow attack, which could result in \r\nDenial-of-Service.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Modicon M580 PLCs, BMENOR2200H and EVLink Pro AC - SEVD-2025-014-01 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-01.pdf"
},
{
"category": "self",
"summary": "Modicon M580 PLCs, BMENOR2200H and EVLink Pro AC - SEVD-2025-014-01 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-014-01.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390"
}
],
"title": "Modicon M580 PLCs, BMENOR2200H and EVLink Pro AC",
"tracking": {
"current_release_date": "2025-04-08T04:00:00.000Z",
"generator": {
"date": "2025-04-08T00:00:00Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2025-014-01",
"initial_release_date": "2025-01-14T05:00:00.000Z",
"revision_history": [
{
"date": "2025-01-14T05:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2025-04-08T04:00:00.000Z",
"number": "2.0.0",
"summary": "A remediation is now available for BMENOR2200H."
}
],
"status": "final",
"version": "2.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV4.30",
"product": {
"name": "Schneider Electric Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety) Versions prior to SV4.30",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"BMEP*",
"BMEH*"
]
}
}
},
{
"category": "product_version",
"name": "SV4.30",
"product": {
"name": "Schneider Electric Modicon M580 SV4.30",
"product_id": "5",
"product_identification_helper": {
"model_numbers": [
"BMEP*",
"BMEH*"
]
}
}
}
],
"category": "product_name",
"name": "Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV4.21",
"product": {
"name": "Schneider Electric Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) Versions prior to SV4.21",
"product_id": "2",
"product_identification_helper": {
"model_numbers": [
"BMEP58*S",
"BMEH58*S"
]
}
}
},
{
"category": "product_version",
"name": "SV4.21",
"product": {
"name": "Schneider Electric Modicon M580 SV4.21",
"product_id": "6",
"product_identification_helper": {
"model_numbers": [
"BMEP58*S",
"BMEH58*S"
]
}
}
}
],
"category": "product_name",
"name": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV4.02.01",
"product": {
"name": "Schneider Electric BMENOR2200H Versions prior to SV4.02.01",
"product_id": "3"
}
},
{
"category": "product_version",
"name": "SV4.02.01",
"product": {
"name": "Schneider Electric BMENOR2200H Version SV4.02.01",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "BMENOR2200H"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.3.10",
"product": {
"name": "Schneider Electric EVLink Pro AC Versions prior to v1.3.10",
"product_id": "4"
}
},
{
"category": "product_version",
"name": "1.3.10",
"product": {
"name": "Schneider Electric EVLink Pro AC V1.3.10",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "EVLink Pro AC"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-11425",
"cwe": {
"id": "CWE-131",
"name": "Incorrect Calculation of Buffer Size"
},
"notes": [
{
"category": "description",
"text": "CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the \r\nproduct when an unauthenticated user is sending a crafted HTTPS packet to the webserver.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"5",
"6",
"7",
"8"
],
"known_affected": [
"1",
"2",
"3",
"4"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "SV4.30 of Modicon M580 firmware includes a fix for this vulnerability and is \r\navailable for download here:\r\nhttps://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "SV4.21 of Modicon M580 firmware includes a fix for this vulnerability and is \r\navailable for download here:\r\nhttps://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware",
"product_ids": [
"2"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "SV4.02.01 of BMENOR2200H firmware includes a fix for this vulnerability and \r\n is available here:\r\nhttps://www.se.com/ww/en/product/BMENOR2200H/communication-module-modicon-m580-iec-608705101-104-dnp3-for-severe-environments/",
"product_ids": [
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/BMENOR2200H/communication-module-modicon-m580-iec-608705101-104-dnp3-for-severe-environments/"
},
{
"category": "vendor_fix",
"details": "V1.3.10 of EVLink Pro AC firmware includes a fix for this vulnerability and is \r\navailable here:\r\nhttps://www.se.com/ww/en/product-range/23107242-evlink-pro-ac/#software-and-firmware",
"product_ids": [
"4"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/23107242-evlink-pro-ac/#software-and-firmware"
},
{
"category": "mitigation",
"details": "\u2022 Setup network segmentation and implement a firewall to block all unauthorized \r\naccess to port 443/TCP\r\n\u2022 Configure the Access Control List following the recommendations of the user \r\nmanuals: \u201cModicon M580, Hardware, Reference Manual\u201d:\r\nhttps://www.se.com/ww/en/download/document/EIO0000001578/",
"product_ids": [
"1",
"2"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/EIO0000001578/"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit.\u2022 Setup network segmentation and implement a firewall to block all unauthorized \r\naccess to port 443/TCP",
"product_ids": [
"3"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "\u2022 Follow EVlink Pro AC cybersecurity guide\r\nhttps://www.se.com/ww/en/download/document/GEX5261101/",
"product_ids": [
"4"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/GEX5261101/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4"
]
}
],
"title": "CVE-2024-11425"
}
]
}
ICSA-25-035-04
Vulnerability from csaf_cisa - Published: 2025-01-14 05:00 - Updated: 2025-04-08 04:00Notes
{
"document": {
"acknowledgments": [
{
"organization": "Schneider Electric CPCERT",
"summary": "reporting this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability in its Modicon M580 PLCs (Programmable Logic Controllers) https://www.se.com/ww/en/product-range/62098-modicon-m580-epac/?parent-subcategory-id=3950\u0026filter=business-1-industrial-automation-and-control#products , \r\nBMENOR2200H https://www.se.com/ww/en/product/BMENOR2200H/modicon-x80-module-coupleur-rtu-%C3%A9volu%C3%A9-sur-ethernet-1-port-s%C3%A9rie-durci/ and EVLink Pro AC https://www.se.com/ww/en/product-range/23107242-evlink-pro-ac/#products products.\r\nModicon M580 PLCs https://www.se.com/ww/en/product-subcategory/3950-pac-programmable-automation-controllers/?filter=business-1-industrial-automation-and-control control and monitor industrial operations.\r\nBMENOR2200H https://www.se.com/ww/en/product/BMENOR2200H/modicon-x80-module-coupleur-rtu-%C3%A9volu%C3%A9-sur-ethernet-1-port-s%C3%A9rie-durci/ is an advanced RTU communication module for Modicon M580 PLCs.\r\nEVLink Pro AC https://www.se.com/ww/en/product-range/23107242-evlink-pro-ac/#products is a 3rd generation of AC charging station.\r\nFailure to apply the fix or mitigations provided below may risk buffer overflow attack, which could result in \r\nDenial-of-Service.",
"title": "Overview"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Schneider Electric CPCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Commercial Facilities, Critical Manufacturing, Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "Modicon M580 PLCs, BMENOR2200H and EVLink Pro AC - SEVD-2025-014-01 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-014-01.json"
},
{
"category": "self",
"summary": "Modicon M580 PLCs, BMENOR2200H and EVLink Pro AC - SEVD-2025-014-01 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-014-01.pdf"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-035-04 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-035-04.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-035-04 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-035-04"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric EcoStruxure Power Monitoring Expert (PME) (Update A)",
"tracking": {
"current_release_date": "2025-04-08T04:00:00.000000Z",
"generator": {
"date": "2025-04-22T16:46:46.602489Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-035-04",
"initial_release_date": "2025-01-14T05:00:00.000000Z",
"revision_history": [
{
"date": "2025-01-14T05:00:00.000000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2025-04-08T04:00:00.000000Z",
"number": "2.0.0",
"summary": "A remediation is now available for BMENOR2200H."
}
],
"status": "final",
"version": "2.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cSV4.30",
"product": {
"name": "Schneider Electric Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety) Versions prior to SV4.30",
"product_id": "CSAFPID-0001",
"product_identification_helper": {
"model_numbers": [
"BMEP*",
"BMEH*"
]
}
}
},
{
"category": "product_version",
"name": "SV4.30",
"product": {
"name": "Schneider Electric Modicon M580 SV4.30",
"product_id": "CSAFPID-0002",
"product_identification_helper": {
"model_numbers": [
"BMEP*",
"BMEH*"
]
}
}
}
],
"category": "product_name",
"name": "Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cSV4.21",
"product": {
"name": "Schneider Electric Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) Versions prior to SV4.21",
"product_id": "CSAFPID-0003",
"product_identification_helper": {
"model_numbers": [
"BMEP58*S",
"BMEH58*S"
]
}
}
},
{
"category": "product_version",
"name": "SV4.21",
"product": {
"name": "Schneider Electric Modicon M580 SV4.21",
"product_id": "CSAFPID-0004",
"product_identification_helper": {
"model_numbers": [
"BMEP58*S",
"BMEH58*S"
]
}
}
}
],
"category": "product_name",
"name": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV4.02.01",
"product": {
"name": "Schneider Electric BMENOR2200H Versions prior to SV4.02.01",
"product_id": "CSAFPID-0005"
}
},
{
"category": "product_version",
"name": "SV4.02.01",
"product": {
"name": "Schneider Electric BMENOR2200H Version SV4.02.01",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "BMENOR2200H"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003c1.3.10",
"product": {
"name": "Schneider Electric EVLink Pro AC Versions prior to v1.3.10",
"product_id": "CSAFPID-0007"
}
},
{
"category": "product_version",
"name": "1.3.10",
"product": {
"name": "Schneider Electric EVLink Pro AC V1.3.10",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "EVLink Pro AC"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-11425",
"cwe": {
"id": "CWE-131",
"name": "Incorrect Calculation of Buffer Size"
},
"notes": [
{
"category": "description",
"text": "CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the \r\nproduct when an unauthenticated user is sending a crafted HTTPS packet to the webserver.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0002",
"CSAFPID-0004",
"CSAFPID-0008",
"CSAFPID-0006"
],
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0007"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "SV4.30 of Modicon M580 firmware includes a fix for this vulnerability and is \r\navailable for download here:\r\nhttps://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "SV4.21 of Modicon M580 firmware includes a fix for this vulnerability and is \r\navailable for download here:\r\nhttps://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware",
"product_ids": [
"CSAFPID-0003"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "SV4.02.01 of BMENOR2200H firmware includes a fix for this vulnerability and \r\n is available here:\r\nhttps://www.se.com/ww/en/product/BMENOR2200H/communication-module-modicon-m580-iec-608705101-104-dnp3-for-severe-environments/",
"product_ids": [
"CSAFPID-0005"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/BMENOR2200H/communication-module-modicon-m580-iec-608705101-104-dnp3-for-severe-environments/"
},
{
"category": "vendor_fix",
"details": "V1.3.10 of EVLink Pro AC firmware includes a fix for this vulnerability and is \r\navailable here:\r\nhttps://www.se.com/ww/en/product-range/23107242-evlink-pro-ac/#software-and-firmware",
"product_ids": [
"CSAFPID-0007"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/23107242-evlink-pro-ac/#software-and-firmware"
},
{
"category": "mitigation",
"details": "\u2022 Setup network segmentation and implement a firewall to block all unauthorized \r\naccess to port 443/TCP\r\n\u2022 Configure the Access Control List following the recommendations of the user \r\nmanuals: \u201cModicon M580, Hardware, Reference Manual\u201d:\r\nhttps://www.se.com/ww/en/download/document/EIO0000001578/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/EIO0000001578/"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit.\u2022 Setup network segmentation and implement a firewall to block all unauthorized \r\naccess to port 443/TCP",
"product_ids": [
"CSAFPID-0005"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "\u2022 Follow EVlink Pro AC cybersecurity guide\r\nhttps://www.se.com/ww/en/download/document/GEX5261101/",
"product_ids": [
"CSAFPID-0007"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/GEX5261101/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0007"
]
}
],
"title": "CVE-2024-11425"
}
]
}
FKIE_CVE-2024-11425
Vulnerability from fkie_nvd - Published: 2025-01-17 09:15 - Updated: 2025-01-17 09:15| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the\nproduct when an unauthenticated user is sending a crafted HTTPS packet to the webserver."
},
{
"lang": "es",
"value": "CWE-131: Existe una vulnerabilidad de c\u00e1lculo incorrecto del tama\u00f1o del b\u00fafer que podr\u00eda provocar una denegaci\u00f3n de servicio del producto cuando un usuario no autenticado env\u00eda un paquete HTTPS manipulado espec\u00edficamente al servidor web."
}
],
"id": "CVE-2024-11425",
"lastModified": "2025-01-17T09:15:07.613",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "cybersecurity@se.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
},
"published": "2025-01-17T09:15:07.613",
"references": [
{
"source": "cybersecurity@se.com",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-01.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-131"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
NCSC-2025-0019
Vulnerability from csaf_ncscnl - Published: 2025-01-16 11:46 - Updated: 2025-01-16 11:46Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE"
}
},
"lang": "nl",
"notes": [
{
"category": "legal_disclaimer",
"text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings."
},
{
"category": "description",
"text": "Schneider Electric heeft kwetsbaarheden verholpen in Modicon M340, M580 en diverse communicatiemodules.",
"title": "Feiten"
},
{
"category": "description",
"text": "Een kwaadwillende kan de kwetsbaarheden misbruiken om een Denial-of-Service te veroorzaken of toegang te krijgen tot systeemgegevens en mogelijk de werking van de controllers te be\u00efnvloeden.\n\nVoor succesvol misbruik moet de kwaadwillende toegang hebben tot de productie-omgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.",
"title": "Interpretaties"
},
{
"category": "description",
"text": "Schneider Electric heeft updates uitgebracht om de kwetsbaarheden te verhelpen. Zie bijgevoegde referenties voor meer informatie.",
"title": "Oplossingen"
},
{
"category": "general",
"text": "medium",
"title": "Kans"
},
{
"category": "general",
"text": "medium",
"title": "Schade"
},
{
"category": "general",
"text": "Incorrect Calculation of Buffer Size",
"title": "CWE-131"
},
{
"category": "general",
"text": "Exposure of Sensitive Information to an Unauthorized Actor",
"title": "CWE-200"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "cert@ncsc.nl",
"name": "Nationaal Cyber Security Centrum",
"namespace": "https://www.ncsc.nl/"
},
"references": [
{
"category": "external",
"summary": "Reference - schneider",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-014-01.pdf"
},
{
"category": "external",
"summary": "Reference - schneider",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-014-05.pdf"
}
],
"title": "Kwetsbaarheden verholpen in Schneider Electric Modicon",
"tracking": {
"current_release_date": "2025-01-16T11:46:16.661689Z",
"id": "NCSC-2025-0019",
"initial_release_date": "2025-01-16T11:46:16.661689Z",
"revision_history": [
{
"date": "2025-01-16T11:46:16.661689Z",
"number": "0",
"summary": "Initiele versie"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"category": "product_name",
"name": "bmenor2200h",
"product": {
"name": "bmenor2200h",
"product_id": "CSAFPID-1749655",
"product_identification_helper": {
"cpe": "cpe:2.3:a:schneider_electric:bmenor2200h:*:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_name",
"name": "bmxnoe0100",
"product": {
"name": "bmxnoe0100",
"product_id": "CSAFPID-1749650",
"product_identification_helper": {
"cpe": "cpe:2.3:a:schneider_electric:bmxnoe0100:*:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_name",
"name": "bmxnoe0110",
"product": {
"name": "bmxnoe0110",
"product_id": "CSAFPID-1749651",
"product_identification_helper": {
"cpe": "cpe:2.3:a:schneider_electric:bmxnoe0110:*:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_name",
"name": "bmxnor0200h",
"product": {
"name": "bmxnor0200h",
"product_id": "CSAFPID-1749652",
"product_identification_helper": {
"cpe": "cpe:2.3:a:schneider_electric:bmxnor0200h:*:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_name",
"name": "evlink_pro_ac",
"product": {
"name": "evlink_pro_ac",
"product_id": "CSAFPID-1749656",
"product_identification_helper": {
"cpe": "cpe:2.3:a:schneider_electric:evlink_pro_ac:*:*:*:*:*:*:*:*"
}
}
}
],
"category": "vendor",
"name": "schneider_electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-11425",
"cwe": {
"id": "CWE-131",
"name": "Incorrect Calculation of Buffer Size"
},
"notes": [
{
"category": "other",
"text": "Incorrect Calculation of Buffer Size",
"title": "CWE-131"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1749655",
"CSAFPID-1749656"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2024-11425",
"url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-11425.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1749655",
"CSAFPID-1749656"
]
}
],
"title": "CVE-2024-11425"
},
{
"cve": "CVE-2024-12142",
"cwe": {
"id": "CWE-200",
"name": "Exposure of Sensitive Information to an Unauthorized Actor"
},
"notes": [
{
"category": "other",
"text": "Exposure of Sensitive Information to an Unauthorized Actor",
"title": "CWE-200"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1749650",
"CSAFPID-1749651",
"CSAFPID-1749652"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2024-12142",
"url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-12142.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1749650",
"CSAFPID-1749651",
"CSAFPID-1749652"
]
}
],
"title": "CVE-2024-12142"
}
]
}
GHSA-M2F5-73VQ-2MP8
Vulnerability from github – Published: 2025-01-17 09:30 – Updated: 2025-01-17 09:30CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the product when an unauthenticated user is sending a crafted HTTPS packet to the webserver.
{
"affected": [],
"aliases": [
"CVE-2024-11425"
],
"database_specific": {
"cwe_ids": [
"CWE-131"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2025-01-17T09:15:07Z",
"severity": "HIGH"
},
"details": "CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the\nproduct when an unauthenticated user is sending a crafted HTTPS packet to the webserver.",
"id": "GHSA-m2f5-73vq-2mp8",
"modified": "2025-01-17T09:30:38Z",
"published": "2025-01-17T09:30:38Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-11425"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-01.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
},
{
"score": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"type": "CVSS_V4"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.