Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    24 vulnerabilities found for PowerPath Management Appliance by Dell

    VAR-202211-1330

    Vulnerability from variot - Updated: 2023-12-18 13:55

    PowerPath Management Appliance with versions 3.3 & 3.2* contains a Hardcoded Cryptographic Keys vulnerability. Authenticated admin users can exploit the issue that leads to view and modifying sensitive information stored in the application

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1330",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.2"
          },
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.3"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.2"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.3"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014215"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34449"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.2:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.3:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34449"
          }
        ]
      },
      "cve": "CVE-2022-34449",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 6.0,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.8,
                "impactScore": 5.2,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "OTHER",
                "availabilityImpact": "None",
                "baseScore": 6.0,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2022-014215",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2022-34449",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2022-34449",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2022-014215",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202211-3196",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014215"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34449"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34449"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3196"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2* contains a Hardcoded Cryptographic Keys vulnerability. Authenticated admin users can exploit the issue that leads to view and modifying sensitive information stored in the application",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34449"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014215"
          },
          {
            "db": "VULHUB",
            "id": "VHN-426765"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34449"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-34449",
            "trust": 3.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014215",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3196",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-426765",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34449",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426765"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34449"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014215"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34449"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3196"
          }
        ]
      },
      "id": "VAR-202211-1330",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426765"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T13:55:11.016000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "DSA-2022-283",
            "trust": 0.8,
            "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
          },
          {
            "title": "Dell PowerPath Management Appliance Repair measures for trust management problem vulnerabilities",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=226313"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014215"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3196"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-798",
            "trust": 1.1
          },
          {
            "problemtype": "Use hard-coded credentials (CWE-798) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426765"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014215"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34449"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://www.dell.com/support/kbdoc/000205404"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-34449"
          },
          {
            "trust": 0.6,
            "url": "https://vigilance.fr/vulnerability/dell-powerpath-management-appliance-seven-vulnerabilities-39945"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-34449/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426765"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34449"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014215"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34449"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3196"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-426765"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34449"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014215"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34449"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3196"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-02-11T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426765"
          },
          {
            "date": "2023-02-11T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34449"
          },
          {
            "date": "2023-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-014215"
          },
          {
            "date": "2023-02-11T01:23:25.083000",
            "db": "NVD",
            "id": "CVE-2022-34449"
          },
          {
            "date": "2022-11-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-3196"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-02-21T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426765"
          },
          {
            "date": "2023-02-12T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34449"
          },
          {
            "date": "2023-09-15T06:48:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-014215"
          },
          {
            "date": "2023-11-07T03:48:42.250000",
            "db": "NVD",
            "id": "CVE-2022-34449"
          },
          {
            "date": "2023-02-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-3196"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3196"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "PowerPath\u00a0Management\u00a0Appliance\u00a0 Vulnerability in using hard-coded credentials in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014215"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "trust management problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3196"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202211-1324

    Vulnerability from variot - Updated: 2023-12-18 13:41

    PowerPath Management Appliance with versions 3.3 & 3.2* contains Authorization Bypass vulnerability. An authenticated remote user with limited privileges (e.g., of role Monitoring) can exploit this issue and gain access to sensitive information, and modify the configuration. PowerPath Management Appliance Exists in unspecified vulnerabilities.Information may be obtained and information may be tampered with

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1324",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.2"
          },
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.3"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.2"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.3"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014212"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34446"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.2:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.3:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34446"
          }
        ]
      },
      "cve": "CVE-2022-34446",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "impactScore": 5.2,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "security_alert@emc.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 8.1,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2022-34446",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2022-34446",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2022-34446",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202211-3230",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014212"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34446"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34446"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3230"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2* contains Authorization Bypass vulnerability. An authenticated remote user with limited privileges (e.g., of role Monitoring) can exploit this issue and gain access to sensitive information, and modify the configuration. PowerPath Management Appliance Exists in unspecified vulnerabilities.Information may be obtained and information may be tampered with",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34446"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014212"
          },
          {
            "db": "VULHUB",
            "id": "VHN-426762"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34446"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-34446",
            "trust": 3.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014212",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3230",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-426762",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34446",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426762"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34446"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014212"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34446"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3230"
          }
        ]
      },
      "id": "VAR-202211-1324",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426762"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T13:41:47.472000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "DSA-2022-283",
            "trust": 0.8,
            "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
          },
          {
            "title": "Dell PowerPath Management Appliance Security vulnerabilities",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=247154"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014212"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3230"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-Other",
            "trust": 1.0
          },
          {
            "problemtype": "others (CWE-Other) [NVD evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-287",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426762"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014212"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34446"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://www.dell.com/support/kbdoc/000205404"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-34446"
          },
          {
            "trust": 0.6,
            "url": "https://vigilance.fr/vulnerability/dell-powerpath-management-appliance-seven-vulnerabilities-39945"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-34446/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426762"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34446"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014212"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34446"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3230"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-426762"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34446"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014212"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34446"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3230"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-02-11T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426762"
          },
          {
            "date": "2023-02-11T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34446"
          },
          {
            "date": "2023-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-014212"
          },
          {
            "date": "2023-02-11T01:23:24.780000",
            "db": "NVD",
            "id": "CVE-2022-34446"
          },
          {
            "date": "2022-11-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-3230"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-02-21T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426762"
          },
          {
            "date": "2023-02-12T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34446"
          },
          {
            "date": "2023-09-15T06:43:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-014212"
          },
          {
            "date": "2023-11-07T03:48:42.020000",
            "db": "NVD",
            "id": "CVE-2022-34446"
          },
          {
            "date": "2023-07-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-3230"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3230"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "PowerPath\u00a0Management\u00a0Appliance\u00a0 Vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014212"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3230"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202211-1366

    Vulnerability from variot - Updated: 2023-12-18 13:41

    PowerPath Management Appliance with versions 3.3 & 3.2, 3.1 & 3.0 contains a Cross-site Request Forgery vulnerability. An unauthenticated non-privileged user could potentially exploit the issue and perform any privileged state-changing actions. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1366",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.2"
          },
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.0"
          },
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.3"
          },
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.1"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.0"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.2"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.3"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.1"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014214"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34448"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.1:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.2:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.3:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34448"
          }
        ]
      },
      "cve": "CVE-2022-34448",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2022-014214",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2022-34448",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2022-34448",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2022-014214",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202211-3206",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014214"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34448"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34448"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3206"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2*, 3.1 \u0026 3.0* contains a Cross-site Request Forgery vulnerability. An unauthenticated non-privileged user could potentially exploit the issue and perform any privileged state-changing actions. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34448"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014214"
          },
          {
            "db": "VULHUB",
            "id": "VHN-426764"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34448"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-34448",
            "trust": 3.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014214",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3206",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-426764",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34448",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426764"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34448"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014214"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34448"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3206"
          }
        ]
      },
      "id": "VAR-202211-1366",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426764"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T13:41:47.405000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "DSA-2022-283",
            "trust": 0.8,
            "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014214"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-352",
            "trust": 1.1
          },
          {
            "problemtype": "Cross-site request forgery (CWE-352) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426764"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014214"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34448"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://www.dell.com/support/kbdoc/000205404"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-34448"
          },
          {
            "trust": 0.6,
            "url": "https://vigilance.fr/vulnerability/dell-powerpath-management-appliance-seven-vulnerabilities-39945"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-34448/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426764"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34448"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014214"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34448"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3206"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-426764"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34448"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014214"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34448"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3206"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-02-11T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426764"
          },
          {
            "date": "2023-02-11T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34448"
          },
          {
            "date": "2023-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-014214"
          },
          {
            "date": "2023-02-11T01:23:24.997000",
            "db": "NVD",
            "id": "CVE-2022-34448"
          },
          {
            "date": "2022-11-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-3206"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-02-21T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426764"
          },
          {
            "date": "2023-02-12T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34448"
          },
          {
            "date": "2023-09-15T06:46:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-014214"
          },
          {
            "date": "2023-11-07T03:48:42.170000",
            "db": "NVD",
            "id": "CVE-2022-34448"
          },
          {
            "date": "2023-02-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-3206"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3206"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "PowerPath\u00a0Management\u00a0Appliance\u00a0 Cross-site request forgery vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014214"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "cross-site request forgery",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3206"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-1050

    Vulnerability from variot - Updated: 2023-12-18 13:37

    Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-1050",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.2"
          },
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.0"
          },
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "2.6"
          },
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.1"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.2"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.0"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "2.6"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.1"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.0 p01"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017063"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-43587"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:2.6:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.0:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.0:patch_01:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.1:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.2:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-43587"
          }
        ]
      },
      "cve": "CVE-2021-43587",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Local",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 7.2,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2021-43587",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.9,
                "userInteractionRequired": null,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "VHN-406225",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:L/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.8,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "security_alert@emc.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.5,
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.7,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-43587",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2021-43587",
                "trust": 1.8,
                "value": "MEDIUM"
              },
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2021-43587",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-805",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-406225",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-43587",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-406225"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-43587"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017063"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-43587"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-43587"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-805"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-43587"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017063"
          },
          {
            "db": "VULHUB",
            "id": "VHN-406225"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-43587"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-43587",
            "trust": 3.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017063",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-805",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-406225",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-43587",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-406225"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-43587"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017063"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-43587"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-805"
          }
        ]
      },
      "id": "VAR-202112-1050",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-406225"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T13:37:10.598000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "DSA-2021-260",
            "trust": 0.8,
            "url": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017063"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-321",
            "trust": 1.1
          },
          {
            "problemtype": "Using hardcoded encryption keys (CWE-321) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-406225"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017063"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-43587"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-43587"
          },
          {
            "trust": 0.6,
            "url": "https://vigilance.fr/vulnerability/dell-powerpath-management-appliance-weak-encryption-via-hard-coded-encryption-key-37046"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/321.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-406225"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-43587"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017063"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-43587"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-805"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-406225"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-43587"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017063"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-43587"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-805"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-21T00:00:00",
            "db": "VULHUB",
            "id": "VHN-406225"
          },
          {
            "date": "2021-12-21T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-43587"
          },
          {
            "date": "2022-12-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017063"
          },
          {
            "date": "2021-12-21T17:15:08.357000",
            "db": "NVD",
            "id": "CVE-2021-43587"
          },
          {
            "date": "2021-12-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-805"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-05T00:00:00",
            "db": "VULHUB",
            "id": "VHN-406225"
          },
          {
            "date": "2022-01-05T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-43587"
          },
          {
            "date": "2022-12-28T05:46:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017063"
          },
          {
            "date": "2022-01-05T14:29:44.017000",
            "db": "NVD",
            "id": "CVE-2021-43587"
          },
          {
            "date": "2022-01-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-805"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-805"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dell\u00a0PowerPath\u00a0Management\u00a0Appliance\u00a0 Vulnerability related to the use of hard-coded encryption keys in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017063"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-805"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202211-1326

    Vulnerability from variot - Updated: 2023-12-18 13:31

    PowerPath Management Appliance with versions 3.3 & 3.2, 3.1 & 3.0 contains OS Command Injection vulnerability. An authenticated remote attacker with administrative privileges could potentially exploit the issue and execute commands on the system as the root user. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1326",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.2"
          },
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.0"
          },
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.3"
          },
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.1"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.0"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.2"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.3"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.1"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014213"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34447"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.1:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.2:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.3:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34447"
          }
        ]
      },
      "cve": "CVE-2022-34447",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.2,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.2,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2022-014213",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2022-34447",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2022-34447",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2022-014213",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202211-3217",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014213"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34447"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34447"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3217"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2*, 3.1 \u0026 3.0* contains OS Command Injection vulnerability. An authenticated remote attacker with administrative privileges could potentially exploit the issue and execute commands on the system as the root user. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34447"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014213"
          },
          {
            "db": "VULHUB",
            "id": "VHN-426763"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34447"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-34447",
            "trust": 3.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014213",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3217",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-426763",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34447",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426763"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34447"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014213"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34447"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3217"
          }
        ]
      },
      "id": "VAR-202211-1326",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426763"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T13:31:53.694000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "DSA-2022-283",
            "trust": 0.8,
            "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014213"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.1
          },
          {
            "problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426763"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014213"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34447"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://www.dell.com/support/kbdoc/000205404"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-34447"
          },
          {
            "trust": 0.6,
            "url": "https://vigilance.fr/vulnerability/dell-powerpath-management-appliance-seven-vulnerabilities-39945"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-34447/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426763"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34447"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014213"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34447"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3217"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-426763"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34447"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014213"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34447"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3217"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-02-11T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426763"
          },
          {
            "date": "2023-02-11T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34447"
          },
          {
            "date": "2023-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-014213"
          },
          {
            "date": "2023-02-11T01:23:24.903000",
            "db": "NVD",
            "id": "CVE-2022-34447"
          },
          {
            "date": "2022-11-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-3217"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-02-21T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426763"
          },
          {
            "date": "2023-02-12T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34447"
          },
          {
            "date": "2023-09-15T06:44:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-014213"
          },
          {
            "date": "2023-11-07T03:48:42.100000",
            "db": "NVD",
            "id": "CVE-2022-34447"
          },
          {
            "date": "2023-02-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-3217"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3217"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "PowerPath\u00a0Management\u00a0Appliance\u00a0 In \u00a0OS\u00a0 Command injection vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014213"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3217"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202211-1335

    Vulnerability from variot - Updated: 2023-12-18 13:11

    PowerPath Management Appliance with versions 3.3, 3.2, 3.1 & 3.0 contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1335",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "powerpath management appliance",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.0"
          },
          {
            "model": "powerpath management appliance",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.4"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.0*"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.1"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.2*"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.3"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-013476"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34452"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.4",
                    "versionStartIncluding": "3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34452"
          }
        ]
      },
      "cve": "CVE-2022-34452",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.2,
                "impactScore": 1.4,
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "None",
                "baseScore": 2.7,
                "baseSeverity": "Low",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "JVNDB-2022-013476",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2022-34452",
                "trust": 1.0,
                "value": "LOW"
              },
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2022-34452",
                "trust": 1.0,
                "value": "LOW"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2022-013476",
                "trust": 0.8,
                "value": "Low"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202211-3180",
                "trust": 0.6,
                "value": "LOW"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-013476"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34452"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34452"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3180"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "\nPowerPath Management Appliance with versions 3.3, 3.2*, 3.1 \u0026 3.0* contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34452"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-013476"
          },
          {
            "db": "VULHUB",
            "id": "VHN-426768"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34452"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-34452",
            "trust": 3.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-013476",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3180",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-426768",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34452",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426768"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34452"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-013476"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34452"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3180"
          }
        ]
      },
      "id": "VAR-202211-1335",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426768"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T13:11:45.522000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "DSA-2022-283",
            "trust": 0.8,
            "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
          },
          {
            "title": "",
            "trust": 0.1,
            "url": "https://github.com/live-hack-cve/cve-2022-34452 "
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2022-34452"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-013476"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-668",
            "trust": 1.1
          },
          {
            "problemtype": "Leakage of resources to the wrong area (CWE-668) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426768"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-013476"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34452"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-34452"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-34452/"
          },
          {
            "trust": 0.6,
            "url": "https://vigilance.fr/vulnerability/dell-powerpath-management-appliance-seven-vulnerabilities-39945"
          },
          {
            "trust": 0.1,
            "url": "https://github.com/live-hack-cve/cve-2022-34452"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426768"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34452"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-013476"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34452"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3180"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-426768"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34452"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-013476"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34452"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3180"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-02-10T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426768"
          },
          {
            "date": "2023-02-10T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34452"
          },
          {
            "date": "2023-09-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-013476"
          },
          {
            "date": "2023-02-10T10:15:10.853000",
            "db": "NVD",
            "id": "CVE-2022-34452"
          },
          {
            "date": "2022-11-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-3180"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-02-17T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426768"
          },
          {
            "date": "2023-02-10T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34452"
          },
          {
            "date": "2023-09-08T03:06:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-013476"
          },
          {
            "date": "2023-11-07T03:48:42.583000",
            "db": "NVD",
            "id": "CVE-2022-34452"
          },
          {
            "date": "2023-02-20T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-3180"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3180"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "PowerPath\u00a0Management\u00a0Appliance\u00a0 Vulnerability in leaking resources to the wrong area in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-013476"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3180"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202211-1399

    Vulnerability from variot - Updated: 2023-12-18 12:54

    PowerPath Management Appliance with version 3.3 contains Privilege Escalation vulnerability. An authenticated admin user could potentially exploit this issue and gain unrestricted control/code execution on the system as root. PowerPath Management Appliance Exists in unspecified vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1399",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.3"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.3"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014216"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34450"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.3:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34450"
          }
        ]
      },
      "cve": "CVE-2022-34450",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.8,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 6.7,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2022-014216",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2022-34450",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2022-34450",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2022-014216",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202211-3194",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014216"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34450"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34450"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3194"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "\nPowerPath Management Appliance with version 3.3 contains Privilege Escalation vulnerability. An authenticated admin user could potentially exploit this issue and gain unrestricted control/code execution on the system as root. PowerPath Management Appliance Exists in unspecified vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34450"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014216"
          },
          {
            "db": "VULHUB",
            "id": "VHN-426766"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34450"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-34450",
            "trust": 3.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014216",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3194",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-426766",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34450",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426766"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34450"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014216"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34450"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3194"
          }
        ]
      },
      "id": "VAR-202211-1399",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426766"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T12:54:41.087000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "DSA-2022-283",
            "trust": 0.8,
            "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014216"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-Other",
            "trust": 1.0
          },
          {
            "problemtype": "others (CWE-Other) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014216"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34450"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://www.dell.com/support/kbdoc/000205404"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-34450"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-34450/"
          },
          {
            "trust": 0.6,
            "url": "https://vigilance.fr/vulnerability/dell-powerpath-management-appliance-seven-vulnerabilities-39945"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426766"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34450"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014216"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34450"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3194"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-426766"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34450"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014216"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34450"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3194"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-02-11T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426766"
          },
          {
            "date": "2023-02-11T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34450"
          },
          {
            "date": "2023-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-014216"
          },
          {
            "date": "2023-02-11T01:23:25.163000",
            "db": "NVD",
            "id": "CVE-2022-34450"
          },
          {
            "date": "2022-11-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-3194"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-02-21T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426766"
          },
          {
            "date": "2023-02-12T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34450"
          },
          {
            "date": "2023-09-15T06:49:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-014216"
          },
          {
            "date": "2023-11-07T03:48:42.320000",
            "db": "NVD",
            "id": "CVE-2022-34450"
          },
          {
            "date": "2023-02-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-3194"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3194"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "PowerPath\u00a0Management\u00a0Appliance\u00a0 Vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014216"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3194"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202211-1296

    Vulnerability from variot - Updated: 2023-12-18 12:48

    PowerPath Management Appliance with versions 3.3 & 3.2, 3.1 & 3.0 contains a Stored Cross-site Scripting Vulnerability. An authenticated admin user could potentially exploit this vulnerability, to hijack user sessions or trick a victim application user into unknowingly send arbitrary requests to the server

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1296",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.2"
          },
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.0"
          },
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.3"
          },
          {
            "model": "powerpath management appliance",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "dell",
            "version": "3.1"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.0"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": null
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.2"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.3"
          },
          {
            "model": "dell powerpath management appliance",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30c7\u30eb",
            "version": "3.1"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014205"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34451"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.1:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.2:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.3:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:dell:powerpath_management_appliance:3.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34451"
          }
        ]
      },
      "cve": "CVE-2022-34451",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.7,
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 2.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "None",
                "baseScore": 4.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "JVNDB-2022-014205",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "High",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2022-34451",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "security_alert@emc.com",
                "id": "CVE-2022-34451",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2022-014205",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202211-3179",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014205"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34451"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34451"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3179"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2*, 3.1 \u0026 3.0* contains a Stored Cross-site Scripting Vulnerability. An authenticated admin user could potentially exploit this vulnerability, to hijack user sessions or trick a victim application user into unknowingly send arbitrary requests to the server",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-34451"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014205"
          },
          {
            "db": "VULHUB",
            "id": "VHN-426767"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34451"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-34451",
            "trust": 3.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014205",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3179",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-426767",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34451",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426767"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34451"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014205"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34451"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3179"
          }
        ]
      },
      "id": "VAR-202211-1296",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426767"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T12:48:23.996000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "DSA-2022-283",
            "trust": 0.8,
            "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014205"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-79",
            "trust": 1.1
          },
          {
            "problemtype": "Cross-site scripting (CWE-79) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426767"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014205"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34451"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://www.dell.com/support/kbdoc/000205404"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-34451"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-34451/"
          },
          {
            "trust": 0.6,
            "url": "https://vigilance.fr/vulnerability/dell-powerpath-management-appliance-seven-vulnerabilities-39945"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-426767"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34451"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014205"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34451"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3179"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-426767"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-34451"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014205"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-34451"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3179"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-02-11T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426767"
          },
          {
            "date": "2023-02-11T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34451"
          },
          {
            "date": "2023-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-014205"
          },
          {
            "date": "2023-02-11T01:23:25.247000",
            "db": "NVD",
            "id": "CVE-2022-34451"
          },
          {
            "date": "2022-11-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-3179"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-02-21T00:00:00",
            "db": "VULHUB",
            "id": "VHN-426767"
          },
          {
            "date": "2023-02-12T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-34451"
          },
          {
            "date": "2023-09-15T05:32:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-014205"
          },
          {
            "date": "2023-11-07T03:48:42.460000",
            "db": "NVD",
            "id": "CVE-2022-34451"
          },
          {
            "date": "2023-02-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-3179"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3179"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "PowerPath\u00a0Management\u00a0Appliance\u00a0 Cross-site scripting vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-014205"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "XSS",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-3179"
          }
        ],
        "trust": 0.6
      }
    }

    CVE-2022-34451 (GCVE-0-2022-34451)

    Vulnerability from nvd – Published: 2023-02-10 20:59 – Updated: 2025-03-24 18:08
    VLAI
    Summary
    PowerPath Management Appliance with versions 3.3 & 3.2*, 3.1 & 3.0* contains a Stored Cross-site Scripting Vulnerability. An authenticated admin user could potentially exploit this vulnerability, to hijack user sessions or trick a victim application user into unknowingly send arbitrary requests to the server.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerPath Management Appliance Affected: 3.3, 3.2*, 3.1, 3.0*
    Create a notification for this product.
    Date Public
    2022-11-15 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.131Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/000205404"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34451",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T18:08:03.154023Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T18:08:15.328Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.3, 3.2*, 3.1, 3.0*"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cdiv\u003e\u003cdiv\u003ePowerPath Management Appliance with versions 3.3 \u0026amp; 3.2*, 3.1 \u0026amp; 3.0* contains a Stored Cross-site Scripting Vulnerability. An authenticated admin user could potentially exploit this vulnerability, to hijack user sessions or trick a victim application user into unknowingly send arbitrary requests to the server.\u003c/div\u003e\u003c/div\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2*, 3.1 \u0026 3.0* contains a Stored Cross-site Scripting Vulnerability. An authenticated admin user could potentially exploit this vulnerability, to hijack user sessions or trick a victim application user into unknowingly send arbitrary requests to the server.\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T20:59:08.733Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/000205404"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34451",
        "datePublished": "2023-02-10T20:59:08.733Z",
        "dateReserved": "2022-06-23T18:55:17.133Z",
        "dateUpdated": "2025-03-24T18:08:15.328Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34450 (GCVE-0-2022-34450)

    Vulnerability from nvd – Published: 2023-02-10 20:56 – Updated: 2025-03-24 18:09
    VLAI
    Summary
    PowerPath Management Appliance with version 3.3 contains Privilege Escalation vulnerability. An authenticated admin user could potentially exploit this issue and gain unrestricted control/code execution on the system as root.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-183 - Permissive List of Allowed Inputs
    Assigner
    References
    Impacted products
    Date Public
    2022-11-15 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.153Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/000205404"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34450",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T18:08:51.858409Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T18:09:00.932Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.3"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cdiv\u003e\u003cdiv\u003ePowerPath Management Appliance with version 3.3 contains Privilege Escalation vulnerability. An authenticated admin user could potentially exploit this issue and gain unrestricted control/code execution on the system as root.\u003c/div\u003e\u003c/div\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with version 3.3 contains Privilege Escalation vulnerability. An authenticated admin user could potentially exploit this issue and gain unrestricted control/code execution on the system as root.\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-183",
                  "description": "CWE-183: Permissive List of Allowed Inputs",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T20:56:32.939Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/000205404"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34450",
        "datePublished": "2023-02-10T20:56:32.939Z",
        "dateReserved": "2022-06-23T18:55:17.132Z",
        "dateUpdated": "2025-03-24T18:09:00.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34449 (GCVE-0-2022-34449)

    Vulnerability from nvd – Published: 2023-02-10 20:53 – Updated: 2025-03-24 18:09
    VLAI
    Summary
    PowerPath Management Appliance with versions 3.3 & 3.2* contains a Hardcoded Cryptographic Keys vulnerability. Authenticated admin users can exploit the issue that leads to view and modifying sensitive information stored in the application.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    References
    Impacted products
    Date Public
    2022-11-15 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.093Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/000205404"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34449",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T18:09:36.800493Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T18:09:46.068Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.3,3.2*"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cdiv\u003e\u003cdiv\u003ePowerPath Management Appliance with versions 3.3 \u0026amp; 3.2* contains a Hardcoded Cryptographic Keys vulnerability. Authenticated admin users can exploit the issue that leads to view and modifying sensitive information stored in the application.\u003c/div\u003e\u003c/div\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2* contains a Hardcoded Cryptographic Keys vulnerability. Authenticated admin users can exploit the issue that leads to view and modifying sensitive information stored in the application.\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798: Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T20:53:57.070Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/000205404"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34449",
        "datePublished": "2023-02-10T20:53:57.070Z",
        "dateReserved": "2022-06-23T18:55:17.132Z",
        "dateUpdated": "2025-03-24T18:09:46.068Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34448 (GCVE-0-2022-34448)

    Vulnerability from nvd – Published: 2023-02-10 20:51 – Updated: 2025-03-26 15:13
    VLAI
    Summary
    PowerPath Management Appliance with versions 3.3 & 3.2*, 3.1 & 3.0* contains a Cross-site Request Forgery vulnerability. An unauthenticated non-privileged user could potentially exploit the issue and perform any privileged state-changing actions.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-352 - Cross-Site Request Forgery (CSRF)
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerPath Management Appliance Affected: 3.3, 3.2*, 3.1, 3.0*
    Create a notification for this product.
    Date Public
    2022-11-15 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.092Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/000205404"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34448",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T14:31:44.520729Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-26T15:13:37.965Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.3, 3.2*, 3.1, 3.0*"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cdiv\u003e\u003cdiv\u003ePowerPath Management Appliance with versions 3.3 \u0026amp; 3.2*, 3.1 \u0026amp; 3.0* contains a Cross-site Request Forgery vulnerability. An unauthenticated non-privileged user could potentially exploit the issue and perform any privileged state-changing actions.\u003c/div\u003e\u003c/div\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2*, 3.1 \u0026 3.0* contains a Cross-site Request Forgery vulnerability. An unauthenticated non-privileged user could potentially exploit the issue and perform any privileged state-changing actions.\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-352",
                  "description": "CWE-352: Cross-Site Request Forgery (CSRF)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T20:51:09.763Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/000205404"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34448",
        "datePublished": "2023-02-10T20:51:09.763Z",
        "dateReserved": "2022-06-23T18:55:17.131Z",
        "dateUpdated": "2025-03-26T15:13:37.965Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34447 (GCVE-0-2022-34447)

    Vulnerability from nvd – Published: 2023-02-10 20:48 – Updated: 2025-03-26 15:13
    VLAI
    Summary
    PowerPath Management Appliance with versions 3.3 & 3.2*, 3.1 & 3.0* contains OS Command Injection vulnerability. An authenticated remote attacker with administrative privileges could potentially exploit the issue and execute commands on the system as the root user.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerPath Management Appliance Affected: 3.3, 3.2*, 3.1, 3.0*
    Create a notification for this product.
    Date Public
    2022-11-15 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.129Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/000205404"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34447",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T14:32:16.499576Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-26T15:13:59.311Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.3, 3.2*, 3.1, 3.0*"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cdiv\u003e\u003cdiv\u003ePowerPath Management Appliance with versions 3.3 \u0026amp; 3.2*, 3.1 \u0026amp; 3.0* contains OS Command Injection vulnerability. An authenticated remote attacker with administrative privileges could potentially exploit the issue and execute commands on the system as the root user.\u003c/div\u003e\u003c/div\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2*, 3.1 \u0026 3.0* contains OS Command Injection vulnerability. An authenticated remote attacker with administrative privileges could potentially exploit the issue and execute commands on the system as the root user.\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T20:48:05.160Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/000205404"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34447",
        "datePublished": "2023-02-10T20:48:05.160Z",
        "dateReserved": "2022-06-23T18:55:17.131Z",
        "dateUpdated": "2025-03-26T15:13:59.311Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34446 (GCVE-0-2022-34446)

    Vulnerability from nvd – Published: 2023-02-10 20:44 – Updated: 2025-03-26 15:14
    VLAI
    Summary
    PowerPath Management Appliance with versions 3.3 & 3.2* contains Authorization Bypass vulnerability. An authenticated remote user with limited privileges (e.g., of role Monitoring) can exploit this issue and gain access to sensitive information, and modify the configuration.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Date Public
    2022-11-15 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.294Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/000205404"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34446",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-26T15:14:22.136061Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-26T15:14:28.164Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.3, 3.2*"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cdiv\u003e\u003cdiv\u003ePowerPath Management Appliance with versions 3.3 \u0026amp; 3.2* contains Authorization Bypass vulnerability. An authenticated remote user with limited privileges (e.g., of role Monitoring) can exploit this issue and gain access to sensitive information, and modify the configuration.\u003c/div\u003e\u003c/div\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2* contains Authorization Bypass vulnerability. An authenticated remote user with limited privileges (e.g., of role Monitoring) can exploit this issue and gain access to sensitive information, and modify the configuration.\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-285",
                  "description": "CWE-285: Improper Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T20:44:34.905Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/000205404"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34446",
        "datePublished": "2023-02-10T20:44:34.905Z",
        "dateReserved": "2022-06-23T18:55:17.130Z",
        "dateUpdated": "2025-03-26T15:14:28.164Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34452 (GCVE-0-2022-34452)

    Vulnerability from nvd – Published: 2023-02-10 09:33 – Updated: 2025-03-24 18:35
    VLAI
    Summary
    PowerPath Management Appliance with versions 3.3, 3.2*, 3.1 & 3.0* contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-598 - Use of GET Request Method With Sensitive Query Strings
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerPath Management Appliance Affected: 0 , ≤ 3.3, 3.2*, 3.1, 3.0* (custom)
    Create a notification for this product.
    Date Public
    2022-11-15 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.200Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34452",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T15:13:46.502868Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T18:35:03.599Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThanOrEqual": "3.3, 3.2*, 3.1, 3.0*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ePowerPath Management Appliance with versions 3.3, 3.2*, 3.1 \u0026amp; 3.0* contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with versions 3.3, 3.2*, 3.1 \u0026 3.0* contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-598",
                  "description": "CWE-598: Use of GET Request Method With Sensitive Query Strings",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T09:33:05.272Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34452",
        "datePublished": "2023-02-10T09:33:05.272Z",
        "dateReserved": "2022-06-23T18:55:17.133Z",
        "dateUpdated": "2025-03-24T18:35:03.599Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43587 (GCVE-0-2021-43587)

    Vulnerability from nvd – Published: 2021-12-21 17:05 – Updated: 2024-09-17 03:44
    VLAI
    Summary
    Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges.
    CWE
    • CWE-321 - Use of Hard-coded Cryptographic Key
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerPath Management Appliance Affected: unspecified , < 3.2 P01 (custom)
    Create a notification for this product.
    Date Public
    2021-12-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:03:08.626Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "3.2 P01",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-12-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "CWE-321: Use of Hard-coded Cryptographic Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-12-21T17:05:31.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2021-12-09",
              "ID": "CVE-2021-43587",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "PowerPath Management Appliance",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "3.2 P01"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges."
                }
              ]
            },
            "impact": {
              "cvss": {
                "baseScore": 8.2,
                "baseSeverity": "High",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-321: Use of Hard-coded Cryptographic Key"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260",
                  "refsource": "MISC",
                  "url": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2021-43587",
        "datePublished": "2021-12-21T17:05:32.037Z",
        "dateReserved": "2021-11-12T00:00:00.000Z",
        "dateUpdated": "2024-09-17T03:44:02.072Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34451 (GCVE-0-2022-34451)

    Vulnerability from cvelistv5 – Published: 2023-02-10 20:59 – Updated: 2025-03-24 18:08
    VLAI
    Summary
    PowerPath Management Appliance with versions 3.3 & 3.2*, 3.1 & 3.0* contains a Stored Cross-site Scripting Vulnerability. An authenticated admin user could potentially exploit this vulnerability, to hijack user sessions or trick a victim application user into unknowingly send arbitrary requests to the server.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerPath Management Appliance Affected: 3.3, 3.2*, 3.1, 3.0*
    Create a notification for this product.
    Date Public
    2022-11-15 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.131Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/000205404"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34451",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T18:08:03.154023Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T18:08:15.328Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.3, 3.2*, 3.1, 3.0*"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cdiv\u003e\u003cdiv\u003ePowerPath Management Appliance with versions 3.3 \u0026amp; 3.2*, 3.1 \u0026amp; 3.0* contains a Stored Cross-site Scripting Vulnerability. An authenticated admin user could potentially exploit this vulnerability, to hijack user sessions or trick a victim application user into unknowingly send arbitrary requests to the server.\u003c/div\u003e\u003c/div\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2*, 3.1 \u0026 3.0* contains a Stored Cross-site Scripting Vulnerability. An authenticated admin user could potentially exploit this vulnerability, to hijack user sessions or trick a victim application user into unknowingly send arbitrary requests to the server.\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T20:59:08.733Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/000205404"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34451",
        "datePublished": "2023-02-10T20:59:08.733Z",
        "dateReserved": "2022-06-23T18:55:17.133Z",
        "dateUpdated": "2025-03-24T18:08:15.328Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34450 (GCVE-0-2022-34450)

    Vulnerability from cvelistv5 – Published: 2023-02-10 20:56 – Updated: 2025-03-24 18:09
    VLAI
    Summary
    PowerPath Management Appliance with version 3.3 contains Privilege Escalation vulnerability. An authenticated admin user could potentially exploit this issue and gain unrestricted control/code execution on the system as root.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-183 - Permissive List of Allowed Inputs
    Assigner
    References
    Impacted products
    Date Public
    2022-11-15 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.153Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/000205404"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34450",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T18:08:51.858409Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T18:09:00.932Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.3"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cdiv\u003e\u003cdiv\u003ePowerPath Management Appliance with version 3.3 contains Privilege Escalation vulnerability. An authenticated admin user could potentially exploit this issue and gain unrestricted control/code execution on the system as root.\u003c/div\u003e\u003c/div\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with version 3.3 contains Privilege Escalation vulnerability. An authenticated admin user could potentially exploit this issue and gain unrestricted control/code execution on the system as root.\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-183",
                  "description": "CWE-183: Permissive List of Allowed Inputs",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T20:56:32.939Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/000205404"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34450",
        "datePublished": "2023-02-10T20:56:32.939Z",
        "dateReserved": "2022-06-23T18:55:17.132Z",
        "dateUpdated": "2025-03-24T18:09:00.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34449 (GCVE-0-2022-34449)

    Vulnerability from cvelistv5 – Published: 2023-02-10 20:53 – Updated: 2025-03-24 18:09
    VLAI
    Summary
    PowerPath Management Appliance with versions 3.3 & 3.2* contains a Hardcoded Cryptographic Keys vulnerability. Authenticated admin users can exploit the issue that leads to view and modifying sensitive information stored in the application.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    References
    Impacted products
    Date Public
    2022-11-15 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.093Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/000205404"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34449",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T18:09:36.800493Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T18:09:46.068Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.3,3.2*"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cdiv\u003e\u003cdiv\u003ePowerPath Management Appliance with versions 3.3 \u0026amp; 3.2* contains a Hardcoded Cryptographic Keys vulnerability. Authenticated admin users can exploit the issue that leads to view and modifying sensitive information stored in the application.\u003c/div\u003e\u003c/div\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2* contains a Hardcoded Cryptographic Keys vulnerability. Authenticated admin users can exploit the issue that leads to view and modifying sensitive information stored in the application.\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798: Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T20:53:57.070Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/000205404"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34449",
        "datePublished": "2023-02-10T20:53:57.070Z",
        "dateReserved": "2022-06-23T18:55:17.132Z",
        "dateUpdated": "2025-03-24T18:09:46.068Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34448 (GCVE-0-2022-34448)

    Vulnerability from cvelistv5 – Published: 2023-02-10 20:51 – Updated: 2025-03-26 15:13
    VLAI
    Summary
    PowerPath Management Appliance with versions 3.3 & 3.2*, 3.1 & 3.0* contains a Cross-site Request Forgery vulnerability. An unauthenticated non-privileged user could potentially exploit the issue and perform any privileged state-changing actions.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-352 - Cross-Site Request Forgery (CSRF)
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerPath Management Appliance Affected: 3.3, 3.2*, 3.1, 3.0*
    Create a notification for this product.
    Date Public
    2022-11-15 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.092Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/000205404"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34448",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T14:31:44.520729Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-26T15:13:37.965Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.3, 3.2*, 3.1, 3.0*"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cdiv\u003e\u003cdiv\u003ePowerPath Management Appliance with versions 3.3 \u0026amp; 3.2*, 3.1 \u0026amp; 3.0* contains a Cross-site Request Forgery vulnerability. An unauthenticated non-privileged user could potentially exploit the issue and perform any privileged state-changing actions.\u003c/div\u003e\u003c/div\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2*, 3.1 \u0026 3.0* contains a Cross-site Request Forgery vulnerability. An unauthenticated non-privileged user could potentially exploit the issue and perform any privileged state-changing actions.\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-352",
                  "description": "CWE-352: Cross-Site Request Forgery (CSRF)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T20:51:09.763Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/000205404"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34448",
        "datePublished": "2023-02-10T20:51:09.763Z",
        "dateReserved": "2022-06-23T18:55:17.131Z",
        "dateUpdated": "2025-03-26T15:13:37.965Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34447 (GCVE-0-2022-34447)

    Vulnerability from cvelistv5 – Published: 2023-02-10 20:48 – Updated: 2025-03-26 15:13
    VLAI
    Summary
    PowerPath Management Appliance with versions 3.3 & 3.2*, 3.1 & 3.0* contains OS Command Injection vulnerability. An authenticated remote attacker with administrative privileges could potentially exploit the issue and execute commands on the system as the root user.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerPath Management Appliance Affected: 3.3, 3.2*, 3.1, 3.0*
    Create a notification for this product.
    Date Public
    2022-11-15 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.129Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/000205404"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34447",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T14:32:16.499576Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-26T15:13:59.311Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.3, 3.2*, 3.1, 3.0*"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cdiv\u003e\u003cdiv\u003ePowerPath Management Appliance with versions 3.3 \u0026amp; 3.2*, 3.1 \u0026amp; 3.0* contains OS Command Injection vulnerability. An authenticated remote attacker with administrative privileges could potentially exploit the issue and execute commands on the system as the root user.\u003c/div\u003e\u003c/div\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2*, 3.1 \u0026 3.0* contains OS Command Injection vulnerability. An authenticated remote attacker with administrative privileges could potentially exploit the issue and execute commands on the system as the root user.\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T20:48:05.160Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/000205404"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34447",
        "datePublished": "2023-02-10T20:48:05.160Z",
        "dateReserved": "2022-06-23T18:55:17.131Z",
        "dateUpdated": "2025-03-26T15:13:59.311Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34446 (GCVE-0-2022-34446)

    Vulnerability from cvelistv5 – Published: 2023-02-10 20:44 – Updated: 2025-03-26 15:14
    VLAI
    Summary
    PowerPath Management Appliance with versions 3.3 & 3.2* contains Authorization Bypass vulnerability. An authenticated remote user with limited privileges (e.g., of role Monitoring) can exploit this issue and gain access to sensitive information, and modify the configuration.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Date Public
    2022-11-15 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.294Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/000205404"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34446",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-26T15:14:22.136061Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-26T15:14:28.164Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.3, 3.2*"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cdiv\u003e\u003cdiv\u003ePowerPath Management Appliance with versions 3.3 \u0026amp; 3.2* contains Authorization Bypass vulnerability. An authenticated remote user with limited privileges (e.g., of role Monitoring) can exploit this issue and gain access to sensitive information, and modify the configuration.\u003c/div\u003e\u003c/div\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with versions 3.3 \u0026 3.2* contains Authorization Bypass vulnerability. An authenticated remote user with limited privileges (e.g., of role Monitoring) can exploit this issue and gain access to sensitive information, and modify the configuration.\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-285",
                  "description": "CWE-285: Improper Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T20:44:34.905Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/000205404"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34446",
        "datePublished": "2023-02-10T20:44:34.905Z",
        "dateReserved": "2022-06-23T18:55:17.130Z",
        "dateUpdated": "2025-03-26T15:14:28.164Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34452 (GCVE-0-2022-34452)

    Vulnerability from cvelistv5 – Published: 2023-02-10 09:33 – Updated: 2025-03-24 18:35
    VLAI
    Summary
    PowerPath Management Appliance with versions 3.3, 3.2*, 3.1 & 3.0* contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-598 - Use of GET Request Method With Sensitive Query Strings
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerPath Management Appliance Affected: 0 , ≤ 3.3, 3.2*, 3.1, 3.0* (custom)
    Create a notification for this product.
    Date Public
    2022-11-15 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:15:15.200Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34452",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T15:13:46.502868Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T18:35:03.599Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThanOrEqual": "3.3, 3.2*, 3.1, 3.0*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-11-15T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ePowerPath Management Appliance with versions 3.3, 3.2*, 3.1 \u0026amp; 3.0* contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nPowerPath Management Appliance with versions 3.3, 3.2*, 3.1 \u0026 3.0* contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-598",
                  "description": "CWE-598: Use of GET Request Method With Sensitive Query Strings",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-10T09:33:05.272Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34452",
        "datePublished": "2023-02-10T09:33:05.272Z",
        "dateReserved": "2022-06-23T18:55:17.133Z",
        "dateUpdated": "2025-03-24T18:35:03.599Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43587 (GCVE-0-2021-43587)

    Vulnerability from cvelistv5 – Published: 2021-12-21 17:05 – Updated: 2024-09-17 03:44
    VLAI
    Summary
    Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges.
    CWE
    • CWE-321 - Use of Hard-coded Cryptographic Key
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerPath Management Appliance Affected: unspecified , < 3.2 P01 (custom)
    Create a notification for this product.
    Date Public
    2021-12-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:03:08.626Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "PowerPath Management Appliance",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "3.2 P01",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-12-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "CWE-321: Use of Hard-coded Cryptographic Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-12-21T17:05:31.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2021-12-09",
              "ID": "CVE-2021-43587",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "PowerPath Management Appliance",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "3.2 P01"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges."
                }
              ]
            },
            "impact": {
              "cvss": {
                "baseScore": 8.2,
                "baseSeverity": "High",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-321: Use of Hard-coded Cryptographic Key"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260",
                  "refsource": "MISC",
                  "url": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2021-43587",
        "datePublished": "2021-12-21T17:05:32.037Z",
        "dateReserved": "2021-11-12T00:00:00.000Z",
        "dateUpdated": "2024-09-17T03:44:02.072Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }