CVE-2021-43587 (GCVE-0-2021-43587)
Vulnerability from cvelistv5 – Published: 2021-12-21 17:05 – Updated: 2024-09-17 03:44
VLAI?
Summary
Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges.
Severity ?
8.2 (High)
CWE
- CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerPath Management Appliance |
Affected:
unspecified , < 3.2 P01
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:03:08.626Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PowerPath Management Appliance",
"vendor": "Dell",
"versions": [
{
"lessThan": "3.2 P01",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-12-09T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321: Use of Hard-coded Cryptographic Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-21T17:05:31",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-12-09",
"ID": "CVE-2021-43587",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerPath Management Appliance",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "3.2 P01"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges."
}
]
},
"impact": {
"cvss": {
"baseScore": 8.2,
"baseSeverity": "High",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-321: Use of Hard-coded Cryptographic Key"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-43587",
"datePublished": "2021-12-21T17:05:32.037059Z",
"dateReserved": "2021-11-12T00:00:00",
"dateUpdated": "2024-09-17T03:44:02.072Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:dell:powerpath_management_appliance:2.6:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"52816B9C-22F2-441E-91F1-5259597B74A5\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:dell:powerpath_management_appliance:3.0:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"1FEE04FA-1675-4981-ABBC-6B897F262D66\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:dell:powerpath_management_appliance:3.0:patch_01:*:*:*:*:*:*\", \"matchCriteriaId\": \"365876FA-46CC-4AD7-BD47-DC81526B543F\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:dell:powerpath_management_appliance:3.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FC22B1B0-E9A4-44F7-BAA3-7F3F592448FE\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:dell:powerpath_management_appliance:3.2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D92273A9-3C81-4082-9550-DC1497AEDF39\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges.\"}, {\"lang\": \"es\", \"value\": \"Dell PowerPath Management Appliance, versiones 3.2, 3.1, 3.0 P01, 3.0 y 2.6, usan una clave criptogr\\u00e1fica embebida. Un usuario local malicioso con privilegios elevados podr\\u00eda explotar esta vulnerabilidad para conseguir acceso a los secretos y elevarse para conseguir privilegios superiores\"}]",
"id": "CVE-2021-43587",
"lastModified": "2024-11-21T06:29:29.623",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 8.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.5, \"impactScore\": 6.0}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 6.7, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 7.2, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 3.9, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2021-12-21T17:15:08.357",
"references": "[{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260\", \"source\": \"security_alert@emc.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"security_alert@emc.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-321\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-43587\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2021-12-21T17:15:08.357\",\"lastModified\":\"2024-11-21T06:29:29.623\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges.\"},{\"lang\":\"es\",\"value\":\"Dell PowerPath Management Appliance, versiones 3.2, 3.1, 3.0 P01, 3.0 y 2.6, usan una clave criptogr\u00e1fica embebida. Un usuario local malicioso con privilegios elevados podr\u00eda explotar esta vulnerabilidad para conseguir acceso a los secretos y elevarse para conseguir privilegios superiores\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.5,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-321\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerpath_management_appliance:2.6:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"52816B9C-22F2-441E-91F1-5259597B74A5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerpath_management_appliance:3.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"1FEE04FA-1675-4981-ABBC-6B897F262D66\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerpath_management_appliance:3.0:patch_01:*:*:*:*:*:*\",\"matchCriteriaId\":\"365876FA-46CC-4AD7-BD47-DC81526B543F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerpath_management_appliance:3.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FC22B1B0-E9A4-44F7-BAA3-7F3F592448FE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerpath_management_appliance:3.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D92273A9-3C81-4082-9550-DC1497AEDF39\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…