FKIE_CVE-2021-43587
Vulnerability from fkie_nvd - Published: 2021-12-21 17:15 - Updated: 2024-11-21 06:29
Severity ?
8.2 (High) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
6.7 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
6.7 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges.
References
| URL | Tags | ||
|---|---|---|---|
| security_alert@emc.com | https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260 | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260 | Patch, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | powerpath_management_appliance | 2.6 | |
| dell | powerpath_management_appliance | 3.0 | |
| dell | powerpath_management_appliance | 3.0 | |
| dell | powerpath_management_appliance | 3.1 | |
| dell | powerpath_management_appliance | 3.2 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:powerpath_management_appliance:2.6:*:*:*:*:*:*:*",
"matchCriteriaId": "52816B9C-22F2-441E-91F1-5259597B74A5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.0:-:*:*:*:*:*:*",
"matchCriteriaId": "1FEE04FA-1675-4981-ABBC-6B897F262D66",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.0:patch_01:*:*:*:*:*:*",
"matchCriteriaId": "365876FA-46CC-4AD7-BD47-DC81526B543F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.1:*:*:*:*:*:*:*",
"matchCriteriaId": "FC22B1B0-E9A4-44F7-BAA3-7F3F592448FE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.2:*:*:*:*:*:*:*",
"matchCriteriaId": "D92273A9-3C81-4082-9550-DC1497AEDF39",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges."
},
{
"lang": "es",
"value": "Dell PowerPath Management Appliance, versiones 3.2, 3.1, 3.0 P01, 3.0 y 2.6, usan una clave criptogr\u00e1fica embebida. Un usuario local malicioso con privilegios elevados podr\u00eda explotar esta vulnerabilidad para conseguir acceso a los secretos y elevarse para conseguir privilegios superiores"
}
],
"id": "CVE-2021-43587",
"lastModified": "2024-11-21T06:29:29.623",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.5,
"impactScore": 6.0,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-21T17:15:08.357",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000194083/dsa-2021-260"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-321"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…