All the vulnerabilites related to Siemens - SIMATIC CFU PA
var-201910-1595
Vulnerability from variot

A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET200AL, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels, SIMATIC PN/PN Coupler, SIMATIC PROFINET Driver, SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. Affected devices improperly handle large amounts of specially crafted UDP packets.

This could allow an unauthenticated remote attacker to trigger a denial of service condition. Several Siemens products are vulnerable to resource exhaustion.Denial of service (DoS) May be in a state. Siemens SIMATIC CFU PA and so on are the products of Germany's Siemens company. Siemens SIMATIC CFU PA is a compact field device. SIMATIC ET 200AL is a distributed I / O system module. SIMATIC ET 200M is a modular I / O system module for control cabinets for high density channel applications. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), SIMATIC CFU PA (All versions < V1.2.0), SIMATIC ET 200AL (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM 155-5 PN BA (All versions < V4.3.0), SIMATIC ET 200MP IM 155-5 PN HF (All versions), SIMATIC ET 200MP IM 155-5 PN ST (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM 155-6 PN BA (All versions), SIMATIC ET 200SP IM 155-6 PN HA (All versions), SIMATIC ET 200SP IM 155-6 PN HF (All versions < V4.2.2), SIMATIC ET 200SP IM 155-6 PN HS (All versions), SIMATIC ET 200SP IM 155-6 PN ST (All versions), SIMATIC ET 200SP IM 155-6 PN/2 HF (All versions < V4.2.2), SIMATIC ET 200SP IM 155-6 PN/3 HF (All versions < V4.2.1), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels (All versions), SIMATIC PN/PN Coupler (All versions), SIMATIC PROFINET Driver (All versions < V2.1), SIMATIC S7-1200 CPU family (incl. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system. The following products and versions are affected: Siemens SIMATIC S7-1500 CPU series (including: related ET200 CPUs and SIPLUS variants); SIMATIC S7-1500 Software Controller; SIMATIC TDC CP51M1; SIMATIC TDC CPU555; SINAMICS DCM, etc

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201910-1595",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic cfu pa",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "1.2.0"
      },
      {
        "model": "simatic profinet driver",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200al",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200m",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200s",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 1.0,
        "vendor": "sinumerik 828d",
        "version": "4.8"
      },
      {
        "model": "simatic s7-1500t cpu",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "sinamics g150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "simatic s7-410 v8",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "8.2.2"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "simatic winac rtx \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics dcp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.3"
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic et 200sp im 155-6 pn st",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic et 200sp im 155-6 pn hs",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic pn\\/pn coupler",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.1"
      },
      {
        "model": "sinamics s150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "simatic s7-300 cpu 314 ifm",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-300 cpu 318-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic hmi comfort panels 4\\\"",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic et 200pro",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-300 cpu 313",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "sinamics sl150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic hmi comfort outdoor panels 7\\\"",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinumerik 828d",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic s7-400 dp v7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic et 200m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic et 200sp im 155-6 pn ha",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-400h v6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.0.9"
      },
      {
        "model": "simatic et 200sp im 155-6 pn ba",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics g110m",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic et 200mp im 155-5 pn ba",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3.0"
      },
      {
        "model": "simatic et 200s",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics gm150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic s7-300 cpu 316-2 dp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "sinamics g120",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic et 200sp im 155-6 pn\\/3 hf",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.1"
      },
      {
        "model": "simatic s7-1500s cpu",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic hmi comfort outdoor panels 15\\\"",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-300 cpu",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "simatic s7-300 cpu 314",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "sinamics gl150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics g110m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinumerik 828d",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic s7-400 v6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.0.9"
      },
      {
        "model": "simatic et 200mp im 155-5 pn hf",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4.0"
      },
      {
        "model": "sinamics g120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic s7-300 cpu 315-2 dp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "simatic et 200al",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-300 cpu 312 ifm",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "simatic s7-300 cpu 315",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "simatic s7-1500 cpu",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic hmi comfort panels 22\\\"",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics s110",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-1500 cpu 1512c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic s7-1200 cpu 1212c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4.0"
      },
      {
        "model": "ek-ertec 200p",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.6"
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "sinamics gm150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic et 200ecopn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics dcm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.5"
      },
      {
        "model": "ek-ertec 200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic et 200sp im 155-6 pn\\/2 hf",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.2"
      },
      {
        "model": "ek-ertec 200p",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.6"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400 pn v7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic winac rtx \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "simatic s7-1500 cpu 1518",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic s7-1500 cpu 1511c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "simatic s7-1200 cpu 1211c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4.0"
      },
      {
        "model": "sinamics s120",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "sinamics g130",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "simatic s7-1200 cpu",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4.0"
      },
      {
        "model": "simatic et 200mp im 155-5 pn st",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-1200 cpu 1214c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4.0"
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "simatic et 200sp im 155-6 pn hf",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.2"
      },
      {
        "model": "sinamics dcm",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.5"
      },
      {
        "model": "ek-ertec 200",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200p p",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cfu pa",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200mp im 155-5 pn ba",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200mp im 155-5 pn hf",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200mp im 155-5 pn st",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1200 cpu family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "200"
      },
      {
        "model": "ek-ertec 200p",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200mp im pn ba",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "155-5\u003c4.2.3"
      },
      {
        "model": "simatic et 200mp im pn hf",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "155-5"
      },
      {
        "model": "simatic et 200mp im pn st",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "155-5"
      },
      {
        "model": "simatic et 200sp im pn ba",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "155-6"
      },
      {
        "model": "simatic et 200sp im pn ha",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "155-6"
      },
      {
        "model": "simatic et 200sp im pn hf",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "155-6\u003c4.2.2"
      },
      {
        "model": "simatic et 200sp im pn hs",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "155-6"
      },
      {
        "model": "simatic et 200sp im pn st",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "155-6"
      },
      {
        "model": "simatic et 200sp im pn/2 hf",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "155-6\u003c4.2.2"
      },
      {
        "model": "simatic et 200sp im pn/3 hf",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "155-6\u003c4.2.1"
      },
      {
        "model": "simatic et 200ecopn",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200pro",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort outdoor panels 7\" \u0026 15\"",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort panels 4\" 22\"",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic pn/pn coupler",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500 cpu family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-300 cpu family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400 pn/dp",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v7"
      },
      {
        "model": "simatic s7-400 and below",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v6"
      },
      {
        "model": "simatic s7-400h",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v6\u003c6.0.9"
      },
      {
        "model": "simatic s7-410",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "sinamics dcm",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcp",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g110m sp10 hf5",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7\u003cv4.7"
      },
      {
        "model": "sinamics g120 sp10 hf5",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7\u003cv4.7"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "sinamics g150",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics gh150",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "sinamics gm150",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "sinamics s110",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "sinamics s150",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "sinumerik 828d sp5",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.8"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dk standard ethernet controller",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200s",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200sp im 155 6 pn ba",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200sp im 155 6 pn ha",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200sp im 155 6 pn hf",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200sp im 155 6 pn hs",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200sp im 155 6 pn st",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200sp im 155 6 pn 2 hf",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200sp im 155 6 pn 3 hf",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200ecopn",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200pro",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort outdoor panels 7",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort outdoor panels 15",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort panels 4",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort panels 22",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic pn pn coupler",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic profinet driver",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1200 cpu",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1200 cpu 1211c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1200 cpu 1212c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200p",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1200 cpu 1214c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500 cpu",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500s cpu",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500t cpu",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500 cpu 1518",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500 cpu 1511c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500 cpu 1512c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 312 ifm",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 313",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cfu pa",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 314",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 314 ifm",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 315",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 315 2 dp",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 316 2 dp",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300 cpu 318 2",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400 pn v7",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400 dp v7",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400 v6",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400h v6",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200al",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 410 v8",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic winac rtx f 2010",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcm",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcm",
        "version": "1.5"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcp",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g110m",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g120",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g130",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics gl150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics gm150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200m",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s110",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s120",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics sl150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics sm120",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinumerik 828d",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinumerik 840d sl",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200mp im 155 5 pn ba",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200mp im 155 5 pn hf",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200mp im 155 5 pn st",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-36853"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010605"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10936"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.6",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:4.6:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_ba_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_ba:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_hf_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.4.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_hf:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_st_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_st:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ba_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_ba:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ha_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_ha:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hf_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.2.2",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_hf:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hs_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_hs:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_st_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_st:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\\/2_hf_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.2.2",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn\\/2_hf:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\\/3_hf_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.2.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn\\/3_hf:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.2.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_profinet_driver_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.4.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.4.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.4.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.4.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500s_cpu_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500s_cpu:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500t_cpu_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500t_cpu:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_pn_v7_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_pn_v7:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_dp_v7_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_dp_v7:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_v6_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.0.9",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_v6:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.0.9",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "8.2.2",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2010",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.5",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.5:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:5.2:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:5.2:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.8",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.8",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s110_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.2:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sm120_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.8",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp2:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp3:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp4:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-10936"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported this vulnerability to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-639"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2019-10936",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 5.0,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2019-10936",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-36853",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "ea2714fa-253a-4380-82d5-35652a5540fb",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-142532",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2019-10936",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2019-10936",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2019-10936",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-36853",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201910-639",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "ea2714fa-253a-4380-82d5-35652a5540fb",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-142532",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-36853"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142532"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010605"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10936"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10936"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-639"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in  SIMATIC S7-400 CPU 414-3 PN/DP V7,  SIMATIC S7-400 CPU 414F-3 PN/DP V7,  SIMATIC S7-400 CPU 416-3 PN/DP V7,  SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET200AL, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels, SIMATIC PN/PN Coupler, SIMATIC PROFINET Driver, SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. Affected devices improperly handle large amounts of specially crafted UDP packets. \r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition. Several Siemens products are vulnerable to resource exhaustion.Denial of service (DoS) May be in a state. Siemens SIMATIC CFU PA and so on are the products of Germany\u0027s Siemens company. Siemens SIMATIC CFU PA is a compact field device. SIMATIC ET 200AL is a distributed I / O system module. SIMATIC ET 200M is a modular I / O system module for control cabinets for high density channel applications. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), SIMATIC CFU PA (All versions \u003c V1.2.0), SIMATIC ET 200AL (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM 155-5 PN BA (All versions \u003c V4.3.0), SIMATIC ET 200MP IM 155-5 PN HF (All versions), SIMATIC ET 200MP IM 155-5 PN ST (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM 155-6 PN BA (All versions), SIMATIC ET 200SP IM 155-6 PN HA (All versions), SIMATIC ET 200SP IM 155-6 PN HF (All versions \u003c V4.2.2), SIMATIC ET 200SP IM 155-6 PN HS (All versions), SIMATIC ET 200SP IM 155-6 PN ST (All versions), SIMATIC ET 200SP IM 155-6 PN/2 HF (All versions \u003c V4.2.2), SIMATIC ET 200SP IM 155-6 PN/3 HF (All versions \u003c V4.2.1), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions), SIMATIC HMI Comfort Panels 4\" - 22\" (All versions), SIMATIC HMI KTP Mobile Panels (All versions), SIMATIC PN/PN Coupler (All versions), SIMATIC PROFINET Driver (All versions \u003c V2.1), SIMATIC S7-1200 CPU family (incl. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system. The following products and versions are affected: Siemens SIMATIC S7-1500 CPU series (including: related ET200 CPUs and SIPLUS variants); SIMATIC S7-1500 Software Controller; SIMATIC TDC CP51M1; SIMATIC TDC CPU555; SINAMICS DCM, etc",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-10936"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010605"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-36853"
      },
      {
        "db": "IVD",
        "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142532"
      }
    ],
    "trust": 2.43
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-10936",
        "trust": 3.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-473245",
        "trust": 1.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-283-02",
        "trust": 1.4
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-639",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-36853",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010605",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.3813",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.3813.3",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "EA2714FA-253A-4380-82D5-35652A5540FB",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-142532",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-36853"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142532"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010605"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10936"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-639"
      }
    ]
  },
  "id": "VAR-201910-1595",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-36853"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142532"
      }
    ],
    "trust": 1.633110274222222
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-36853"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:13:13.201000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-473245",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf"
      },
      {
        "title": "Patch for Multiple Siemens Product Denial of Service Vulnerabilities (CNVD-2019-36853)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/186551"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-36853"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010605"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-400",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-142532"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010605"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10936"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-283-02"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-10936"
      },
      {
        "trust": 1.2,
        "url": "https://vigilance.fr/vulnerability/simatic-denial-of-service-via-profinet-udp-packets-30562"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10936"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2019.3813/"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-19-283-02"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2019.3813.3/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-36853"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142532"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010605"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10936"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-639"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-36853"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142532"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010605"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10936"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-639"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-10-23T00:00:00",
        "db": "IVD",
        "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-36853"
      },
      {
        "date": "2019-10-10T00:00:00",
        "db": "VULHUB",
        "id": "VHN-142532"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-010605"
      },
      {
        "date": "2019-10-10T14:15:14.707000",
        "db": "NVD",
        "id": "CVE-2019-10936"
      },
      {
        "date": "2019-10-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201910-639"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-36853"
      },
      {
        "date": "2023-01-10T00:00:00",
        "db": "VULHUB",
        "id": "VHN-142532"
      },
      {
        "date": "2019-11-15T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-010605"
      },
      {
        "date": "2023-05-09T13:15:13.053000",
        "db": "NVD",
        "id": "CVE-2019-10936"
      },
      {
        "date": "2023-05-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201910-639"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-639"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Multiple Siemens products vulnerable to resource depletion",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-010605"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Resource management error",
    "sources": [
      {
        "db": "IVD",
        "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201910-639"
      }
    ],
    "trust": 0.8
  }
}

var-202107-1608
Vulnerability from variot

Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. Multiple Siemens products contain vulnerabilities in resource allocation without restrictions or throttling.Service operation interruption (DoS) It may be in a state. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements. Siemens SCALANCE S602是德国西门子(Siemens)公司的一款工业安全设备. Siemens多款产品 存在安全漏洞,该漏洞允许攻击者执行拒绝服务攻击。以下产品和版本受到影响:Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), RUGGEDCOM RM1224 (All Versions < 6.4), SCALANCE M-800 (All Versions < 6.4), SCALANCE S615 (All Versions < 6.4), SCALANCE W1700 IEEE 802.11ac (All versions), SCALANCE W700 IEEE 802.11n (All versions), SCALANCE X200-4 P IRT (All Versions < V5.5.0), SCALANCE X201-3P IRT (All Versions < V5.5.0), SCALANCE X201-3P IRT PRO (All Versions < V5.5.0), SCALANCE X202-2 IRT (All Versions < V5.5.0), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All Versions < V5.5.0), SCALANCE X202-2P IRT PRO (All Versions < V5.5.0), SCALANCE X204 IRT (All Versions < V5.5.0), SCALANCE X204 IRT PRO (All Versions < V5.5.0), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2FM (All versions), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2LD TS (All versions), SCALANCE X204-2TS (All versions), SCALANCE X206-1 (All versions), SCALANCE X206-1LD (incl. SIPLUS NET variant) (All versions), SCALANCE X208 (incl. SIPLUS NET variant) (All versions), SCALANCE X208PRO (All versions), SCALANCE X212-2 (All versions), SCALANCE X212-2LD (All versions), SCALANCE X216 (All versions), SCALANCE X224 (All versions), SCALANCE X302-7EEC (All versions), SCALANCE X304-2FE (All versions), SCALANCE X306-1LDFE (All versions), SCALANCE X307-2EEC (All versions), SCALANCE X307-3 (All versions), SCALANCE X307-3LD (All versions), SCALANCE X308-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X308-2LD (All versions), SCALANCE X308-2LH (All versions), SCALANCE X308-2LH+ (All versions), SCALANCE X308-2M (All versions), SCALANCE X308-2M POE (All versions), SCALANCE X308-2M TS (All versions), SCALANCE X310 (All versions), SCALANCE X310FE (All versions), SCALANCE X320-1FE (All versions), SCALANCE X320-3LDFE (All versions), SCALANCE XB-200 (All versions), SCALANCE XC-200 (All versions), SCALANCE XF-200BA (All versions), SCALANCE XF201-3P IRT (All Versions < V5.5.0), SCALANCE XF202-2P IRT (All Versions < V5.5.0), SCALANCE XF204 (All versions), SCALANCE XF204 IRT (All Versions < V5.5.0), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE XF204-2BA IRT (All Versions < V5.5.0), SCALANCE XF206-1 (All versions), SCALANCE XF208 (All versions), SCALANCE XM400 (All versions < V6.3.1), SCALANCE XP-200 (All versions), SCALANCE XR-300WG (All versions), SCALANCE XR324-12M (All versions), SCALANCE XR324-12M TS (All versions), SCALANCE XR324-4M EEC (All versions), SCALANCE XR324-4M POE (All versions), SCALANCE XR324-4M POE TS (All versions), SCALANCE XR500 (All versions < V6.3.1), SIMATIC CFU PA (All versions), SIMATIC IE/PB-LINK V3 (All versions), SIMATIC MV500 family (All versions < V3.0), SIMATIC NET CM 1542-1 (All versions), SIMATIC NET CP1616/CP1604 (All Versions >= V2.7), SIMATIC NET CP1626 (All versions), SIMATIC NET DK-16xx PN IO (All Versions >= V2.7), SIMATIC PROFINET Driver (All versions), SIMATIC Power Line Booster PLB, Base Module (MLFB: 6ES7972-5AA10-0AB0) (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All Versions < V4.5), SIMOCODE proV Ethernet/IP (All versions < V1.1.3), SIMOCODE proV PROFINET (All versions < V2.1.3), SOFTNET-IE PNIO (All versions)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202107-1608",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xf-200ba",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "scalance x308-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic ie\\/pb-link v3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ek-ertec 200 evaulation kit",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp-200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "scalance x302-7eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x204 irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x204-2ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "simatic power line booster plb",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xr324-12m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance s615",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.4"
      },
      {
        "model": "simatic net cp1604",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x304-2fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr-300wg",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance m-800",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.4"
      },
      {
        "model": "scalance x307-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x202-2p irt pro",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ruggedcom rm1224",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.4"
      },
      {
        "model": "scalance x308-2m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x204-2ts",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "simatic s7-1200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "simatic cfu pa",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x224",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xm400",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.3.1"
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x200-4 p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xf201-3p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "simocode prov ethernet\\/ip",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.3"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "softnet-ie pnio",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc-200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "scalance w1700",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x204-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x212-2ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic net cm 1542-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x201-3p irt pro",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic net cp1616",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic net cp1626",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2ba irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x212-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x201-3p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance w700",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf206-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "dk standard ethernet controller evaluation kit",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic profinet driver",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance xf204 irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x204-2ld ts",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "simocode prov profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.3"
      },
      {
        "model": "ek-ertec 200p evaluation kit",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "scalance x202-2 irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xr500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.3.1"
      },
      {
        "model": "scalance x307-2eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x310fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x204-2fm",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xr324-4m poe ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-4m eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x206-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "simatic mv500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "scalance x320-3ldfe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf202-2p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "simatic net dk-16xx pn io",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "scalance xr324-12m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x204 irt pro",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xb-200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "scalance x208pro",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x206-1ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x200-4p irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "dk standard ethernet controller evaluation kit",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance w1700",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "ek-ertec 200p evaluation kit",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x201-3p irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "ek-ertec 200 evaluation kit",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance w700",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m-800",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "ruggedcom rm1224",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_evaluation_kit_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:dk_standard_ethernet_controller_evaluation_kit:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_evaulation_kit_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200_evaulation_kit:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_evaluation_kit_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200p_evaluation_kit:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rm1224_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rm1224:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_w1700_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_w1700:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x200-4_p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x200-4_p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x201-3p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x201-3p_irt_pro_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x201-3p_irt_pro:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2p_irt_pro_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2p_irt_pro:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204_irt_pro_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204_irt_pro:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2fm_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2fm:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2ld_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2ld_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x206-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x206-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x206-1ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x206-1ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x208pro_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x208pro:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x212-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x212-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x212-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x212-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x216_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x216:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x224_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x224:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-3ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-3ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.3.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.3.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_ie\\/pb-link_v3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_ie\\/pb-link_v3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_mv500_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_mv500:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_net_cm_1542-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_net_cm_1542-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_net_cp1616_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_net_cp1616:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_net_cp1604_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_net_cp1604:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_net_cp1626_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_net_cp1626:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_net_dk-16xx_pn_io:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "2.7",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_power_line_booster_plb_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_power_line_booster_plb:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_profinet_driver_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simocode_prov_ethernet\\/ip_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.1.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simocode_prov_ethernet\\/ip:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simocode_prov_profinet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simocode_prov_profinet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:softnet-ie_pnio_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:softnet-ie_pnio:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported this vulnerability to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2020-28400",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 5.0,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2020-28400",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2020-28400",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2020-28400",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2020-28400",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202104-975",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202107-901",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. Multiple Siemens products contain vulnerabilities in resource allocation without restrictions or throttling.Service operation interruption (DoS) It may be in a state. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements. Siemens SCALANCE S602\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u5de5\u4e1a\u5b89\u5168\u8bbe\u5907. \nSiemens\u591a\u6b3e\u4ea7\u54c1 \u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u5141\u8bb8\u653b\u51fb\u8005\u6267\u884c\u62d2\u7edd\u670d\u52a1\u653b\u51fb\u3002\u4ee5\u4e0b\u4ea7\u54c1\u548c\u7248\u672c\u53d7\u5230\u5f71\u54cd\uff1aDevelopment/Evaluation Kits for PROFINET IO\uff1a DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO\uff1a EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO\uff1a EK-ERTEC 200P (All versions), RUGGEDCOM RM1224 (All Versions \uff1c 6.4), SCALANCE M-800 (All Versions \uff1c 6.4), SCALANCE S615 (All Versions \uff1c 6.4), SCALANCE W1700 IEEE 802.11ac (All versions), SCALANCE W700 IEEE 802.11n (All versions), SCALANCE X200-4 P IRT (All Versions \uff1c V5.5.0), SCALANCE X201-3P IRT (All Versions \uff1c V5.5.0), SCALANCE X201-3P IRT PRO (All Versions \uff1c V5.5.0), SCALANCE X202-2 IRT (All Versions \uff1c V5.5.0), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All Versions \uff1c V5.5.0), SCALANCE X202-2P IRT PRO (All Versions \uff1c V5.5.0), SCALANCE X204 IRT (All Versions \uff1c V5.5.0), SCALANCE X204 IRT PRO (All Versions \uff1c V5.5.0), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2FM (All versions), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2LD TS (All versions), SCALANCE X204-2TS (All versions), SCALANCE X206-1 (All versions), SCALANCE X206-1LD (incl. SIPLUS NET variant) (All versions), SCALANCE X208 (incl. SIPLUS NET variant) (All versions), SCALANCE X208PRO (All versions), SCALANCE X212-2 (All versions), SCALANCE X212-2LD (All versions), SCALANCE X216 (All versions), SCALANCE X224 (All versions), SCALANCE X302-7EEC (All versions), SCALANCE X304-2FE (All versions), SCALANCE X306-1LDFE (All versions), SCALANCE X307-2EEC (All versions), SCALANCE X307-3 (All versions), SCALANCE X307-3LD (All versions), SCALANCE X308-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X308-2LD (All versions), SCALANCE X308-2LH (All versions), SCALANCE X308-2LH+ (All versions), SCALANCE X308-2M (All versions), SCALANCE X308-2M POE (All versions), SCALANCE X308-2M TS (All versions), SCALANCE X310 (All versions), SCALANCE X310FE (All versions), SCALANCE X320-1FE (All versions), SCALANCE X320-3LDFE (All versions), SCALANCE XB-200 (All versions), SCALANCE XC-200 (All versions), SCALANCE XF-200BA (All versions), SCALANCE XF201-3P IRT (All Versions \uff1c V5.5.0), SCALANCE XF202-2P IRT (All Versions \uff1c V5.5.0), SCALANCE XF204 (All versions), SCALANCE XF204 IRT (All Versions \uff1c V5.5.0), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE XF204-2BA IRT (All Versions \uff1c V5.5.0), SCALANCE XF206-1 (All versions), SCALANCE XF208 (All versions), SCALANCE XM400 (All versions \uff1c V6.3.1), SCALANCE XP-200 (All versions), SCALANCE XR-300WG (All versions), SCALANCE XR324-12M (All versions), SCALANCE XR324-12M TS (All versions), SCALANCE XR324-4M EEC (All versions), SCALANCE XR324-4M POE (All versions), SCALANCE XR324-4M POE TS (All versions), SCALANCE XR500 (All versions \uff1c V6.3.1), SIMATIC CFU PA (All versions), SIMATIC IE/PB-LINK V3 (All versions), SIMATIC MV500 family (All versions \uff1c V3.0), SIMATIC NET CM 1542-1 (All versions), SIMATIC NET CP1616/CP1604 (All Versions \uff1e= V2.7), SIMATIC NET CP1626 (All versions), SIMATIC NET DK-16xx PN IO (All Versions \uff1e= V2.7), SIMATIC PROFINET Driver (All versions), SIMATIC Power Line Booster PLB, Base Module (MLFB\uff1a 6ES7972-5AA10-0AB0) (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All Versions \uff1c V4.5), SIMOCODE proV Ethernet/IP (All versions \uff1c V1.1.3), SIMOCODE proV PROFINET (All versions \uff1c V2.1.3), SOFTNET-IE PNIO (All versions)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28400"
      }
    ],
    "trust": 2.79
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-28400",
        "trust": 3.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-194-03",
        "trust": 2.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-599968",
        "trust": 1.7
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133",
        "trust": 0.8
      },
      {
        "db": "CS-HELP",
        "id": "SB2021041363",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.2401",
        "trust": 0.6
      },
      {
        "db": "CS-HELP",
        "id": "SB2021071416",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28400",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2020-28400"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "id": "VAR-202107-1608",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.544597090967742
  },
  "last_update_date": "2024-06-11T21:23:54.270000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-599968",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf"
      },
      {
        "title": "Siemens Various product security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=156594"
      },
      {
        "title": "Siemens Security Advisories: Siemens Security Advisory",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=77fc0ba2dcd8966c9a1f7eb47b8603ca"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2020-28400"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-770",
        "trust": 1.0
      },
      {
        "problemtype": "Allocation of resources without limits or throttling (CWE-770) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28400"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-194-03"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/siemens-ruggedcom-simatic-denial-of-service-via-profinet-dcp-reset-35890"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2021071416"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.2401"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/770.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-599968.txt"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2020-28400"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2020-28400"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-07-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-28400"
      },
      {
        "date": "2022-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "date": "2021-04-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "date": "2021-07-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      },
      {
        "date": "2021-07-13T11:15:08.960000",
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-07-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-28400"
      },
      {
        "date": "2022-06-22T02:38:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "date": "2021-04-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      },
      {
        "date": "2024-06-11T09:15:09.487000",
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerability in limiting or non-slotting resource allocation in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      }
    ],
    "trust": 1.2
  }
}

var-202204-0684
Vulnerability from variot

A vulnerability has been identified in SIMATIC CFU DIQ (6ES7655-5PX31-1XX0), SIMATIC CFU PA (6ES7655-5PX11-0XX0), SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200pro IM154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), SIMATIC ET 200S IM151-8 PN/DP CPU (6ES7151-8AB01-0AB0), SIMATIC ET 200S IM151-8F PN/DP CPU (6ES7151-8FB01-0AB0), SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0), SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0), SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0), SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0), SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0), SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0), SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0), SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0), SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0), SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0), SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0), SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0), SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0), SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0), SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0), SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0), SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0), SINAMICS DCM, SINAMICS G110M, SINAMICS G115D, SINAMICS G120 (incl. SIPLUS variants), SINAMICS G130, SINAMICS G150, SINAMICS S110, SINAMICS S120 (incl. SIPLUS variants), SINAMICS S150, SINAMICS S210 (6SL5...), SINAMICS V90, SIPLUS ET 200S IM151-8 PN/DP CPU (6AG1151-8AB01-7AB0), SIPLUS ET 200S IM151-8F PN/DP CPU (6AG1151-8FB01-2AB0), SIPLUS HCS4200 CIM4210 (6BK1942-1AA00-0AA0), SIPLUS HCS4200 CIM4210C (6BK1942-1AA00-0AA1), SIPLUS HCS4300 CIM4310 (6BK1943-1AA00-0AA0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0), SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0), SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0), SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0), SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0), SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0), SIPLUS S7-400 CPU 414-3 PN/DP V7 (6AG1414-3EM07-7AB0), SIPLUS S7-400 CPU 416-3 PN/DP V7 (6AG1416-3ES07-7AB0). The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.

This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments. simatic cfu diq firmware, SIMATIC CFU PA firmware, SIMATIC S7-300 CPU Multiple Siemens products such as firmware contain a resource exhaustion vulnerability.Service operation interruption (DoS) It may be in a state. The SIMATIC S7-400 CPU family is designed for process control in industrial environments. The SIMATIC S7-300 CPU family is designed for discrete and continuous control in industrial environments. The SIMATIC S7-1500 CPU family is designed for discrete and continuous control in industrial environments. The SIMATIC Compact Field Unit (SIMATIC CFU) is an intelligent field distributor. The SIMATIC ET 200 interface module is used to connect field devices (IO devices) to the controller via PROFINET. SIMATIC TDC is a multiprocessor automation system for drive, control and technical tasks. SIMATIC WinAC RTX is the SIMATIC software controller for PC-based automation solutions. SIPLUSextreme products are designed for reliable operation under extreme conditions. The SIMIT Simulation Platform allows the simulation of plant setups to predict failures at an early planning stage.

A denial of service vulnerability exists in Siemens PROFINET Stack Integrated on Interniche Stack. A vulnerability has been identified in SIMATIC CFU DIQ (All versions), SIMATIC CFU PA (All versions), SIMATIC S7-1500 CPU family (incl. SIPLUS variants) (All versions), SIMATIC TDC CP51M1 (All versions), SIMATIC TDC CPU555 (All versions), SIMATIC WinAC RTX (All versions), SIMIT Simulation Platform (All versions)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0684",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic s7-1500 cpu",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0.0"
      },
      {
        "model": "simatic tdc cpu555",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic cfu diq",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-410 v10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic cfu pa",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic tdc cp51m1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-300 cpu",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simit simulation platform",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-410 v8",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-400h v6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-400 pn\\/dp v7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-410 v10",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic cfu diq",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic s7-400 pn/dp v7",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic s7-1500 cpu",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic s7-410 v8",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic cfu pa",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic s7-300 cpu",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic tdc cp51m1",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic tdc cpu555",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic s7-400h v6",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simit simulation platform",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic winac rtx",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic s7-300 cpu family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500 cpu family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic tdc cp51m1",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic tdc cpu555",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simit simulation platform",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cfu diq",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cfu pa",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400 h cpu family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v6\u003c6.0.10"
      },
      {
        "model": "simatic s7-400 pn/dp cpu family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v7"
      },
      {
        "model": "simatic s7-410 cpu family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8"
      },
      {
        "model": "simatic s7-410 cpu family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v10"
      },
      {
        "model": "simatic winac rtx",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28496"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008398"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25622"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cfu_diq_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cfu_diq:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v7_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp_v7:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-410_v10_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-410_v10:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.0.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simit_simulation_platform:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25622"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported this vulnerability to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2940"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-25622",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 5.0,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2022-25622",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-28496",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2022-25622",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-25622",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2022-25622",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-28496",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202204-2940",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-25622",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28496"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25622"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008398"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2940"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25622"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25622"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC CFU DIQ (6ES7655-5PX31-1XX0), SIMATIC CFU PA (6ES7655-5PX11-0XX0), SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200pro IM154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), SIMATIC ET 200S IM151-8 PN/DP CPU (6ES7151-8AB01-0AB0), SIMATIC ET 200S IM151-8F PN/DP CPU (6ES7151-8FB01-0AB0), SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0), SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0), SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0), SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0), SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0), SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0), SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0), SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0), SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0), SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0), SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0), SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0), SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0), SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0), SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0), SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0), SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0), SINAMICS DCM, SINAMICS G110M, SINAMICS G115D, SINAMICS G120 (incl. SIPLUS variants), SINAMICS G130, SINAMICS G150, SINAMICS S110, SINAMICS S120 (incl. SIPLUS variants), SINAMICS S150, SINAMICS S210 (6SL5...), SINAMICS V90, SIPLUS ET 200S IM151-8 PN/DP CPU (6AG1151-8AB01-7AB0), SIPLUS ET 200S IM151-8F PN/DP CPU (6AG1151-8FB01-2AB0), SIPLUS HCS4200 CIM4210 (6BK1942-1AA00-0AA0), SIPLUS HCS4200 CIM4210C (6BK1942-1AA00-0AA1), SIPLUS HCS4300 CIM4310 (6BK1943-1AA00-0AA0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0), SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0), SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0), SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0), SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0), SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0), SIPLUS S7-400 CPU 414-3 PN/DP V7 (6AG1414-3EM07-7AB0), SIPLUS S7-400 CPU 416-3 PN/DP V7 (6AG1416-3ES07-7AB0). The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. \n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments. simatic cfu diq firmware, SIMATIC CFU PA firmware, SIMATIC S7-300 CPU Multiple Siemens products such as firmware contain a resource exhaustion vulnerability.Service operation interruption (DoS) It may be in a state. The SIMATIC S7-400 CPU family is designed for process control in industrial environments. The SIMATIC S7-300 CPU family is designed for discrete and continuous control in industrial environments. The SIMATIC S7-1500 CPU family is designed for discrete and continuous control in industrial environments. The SIMATIC Compact Field Unit (SIMATIC CFU) is an intelligent field distributor. The SIMATIC ET 200 interface module is used to connect field devices (IO devices) to the controller via PROFINET. SIMATIC TDC is a multiprocessor automation system for drive, control and technical tasks. SIMATIC WinAC RTX is the SIMATIC software controller for PC-based automation solutions. SIPLUSextreme products are designed for reliable operation under extreme conditions. The SIMIT Simulation Platform allows the simulation of plant setups to predict failures at an early planning stage. \n\r\n\r\nA denial of service vulnerability exists in Siemens PROFINET Stack Integrated on Interniche Stack. A vulnerability has been identified in SIMATIC CFU DIQ (All versions), SIMATIC CFU PA (All versions), SIMATIC S7-1500 CPU family (incl. SIPLUS variants) (All versions), SIMATIC TDC CP51M1 (All versions), SIMATIC TDC CPU555 (All versions), SIMATIC WinAC RTX (All versions), SIMIT Simulation Platform (All versions)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25622"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008398"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28496"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25622"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25622",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-446448",
        "trust": 3.1
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-104-06",
        "trust": 1.5
      },
      {
        "db": "JVN",
        "id": "JVNVU91165555",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008398",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28496",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2022.1713",
        "trust": 0.6
      },
      {
        "db": "CS-HELP",
        "id": "SB2022042008",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2940",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25622",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28496"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25622"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008398"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2940"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25622"
      }
    ]
  },
  "id": "VAR-202204-0684",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28496"
      }
    ],
    "trust": 1.3449991391666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28496"
      }
    ]
  },
  "last_update_date": "2024-06-11T22:49:09.624000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Siemens PROFINET Stack Integrated on Interniche Stack Denial of Service Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/329201"
      },
      {
        "title": "Multiple Siemens SIMATIC Product resource management error vulnerability fixes",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=245481"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28496"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2940"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-400",
        "trust": 1.0
      },
      {
        "problemtype": "Resource exhaustion (CWE-400) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008398"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25622"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91165555/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25622"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-104-06"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/simatic-denial-of-service-via-profinet-interniche-ip-stack-38018"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-06"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25622/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2022.1713"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2022042008"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/400.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-06"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28496"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25622"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008398"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2940"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25622"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28496"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25622"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008398"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2940"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25622"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28496"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-25622"
      },
      {
        "date": "2023-07-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-008398"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-2940"
      },
      {
        "date": "2022-04-12T09:15:14.483000",
        "db": "NVD",
        "id": "CVE-2022-25622"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28496"
      },
      {
        "date": "2022-04-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-25622"
      },
      {
        "date": "2023-07-26T08:25:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-008398"
      },
      {
        "date": "2023-07-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-2940"
      },
      {
        "date": "2024-06-11T09:15:10.623000",
        "db": "NVD",
        "id": "CVE-2022-25622"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2940"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Resource Exhaustion Vulnerability in Multiple Siemens Products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008398"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "resource management error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2940"
      }
    ],
    "trust": 0.6
  }
}

cve-2019-10936
Vulnerability from cvelistv5
Published
2019-10-10 00:00
Modified
2024-08-04 22:40
Summary
Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.
Impacted products
Vendor Product Version
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 Version: 0   < *
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P Version: All versions < V4.6 Patch 01
Siemens SIMATIC CFU PA Version: 0   < V1.2.0
Siemens SIMATIC ET 200AL IM 157-1 PN Version: All versions
Siemens SIMATIC ET 200M (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC ET 200MP IM 155-5 PN BA Version: 0   < V4.3.0
Siemens SIMATIC ET 200MP IM 155-5 PN HF Version: 0   < V4.4.0
Siemens SIMATIC ET 200MP IM 155-5 PN ST Version: 0   < *
Siemens SIMATIC ET 200MP IM 155-5 PN ST Version: 0   < *
Siemens SIMATIC ET 200pro IM 154-3 PN HF Version: 0   < *
Siemens SIMATIC ET 200pro IM 154-4 PN HF Version: 0   < *
Siemens SIMATIC ET 200pro IM 154-8 PN/DP CPU Version: All versions < V3.2.17
Siemens SIMATIC ET 200pro IM 154-8F PN/DP CPU Version: All versions < V3.2.17
Siemens SIMATIC ET 200pro IM 154-8FX PN/DP CPU Version: All versions < V3.2.17
Siemens SIMATIC ET 200S IM 151-8 PN/DP CPU Version: All versions < V3.2.17
Siemens SIMATIC ET 200S IM 151-8F PN/DP CPU Version: All versions < V3.2.17
Siemens SIMATIC ET 200SP IM 155-6 PN BA Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) Version: All versions < V1.2.1
Siemens SIMATIC ET 200SP IM 155-6 PN HF Version: 0   < V4.2.2
Siemens SIMATIC ET 200SP IM 155-6 PN HS Version: 0   < V4.0.1
Siemens SIMATIC ET 200SP IM 155-6 PN ST Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN ST Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN ST BA Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN ST BA Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN/2 HF Version: 0   < V4.2.2
Siemens SIMATIC ET 200SP IM 155-6 PN/3 HF Version: 0   < V4.2.1
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) Version: 0   < V2.0
Siemens SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 4AO U/I 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN: IO-Link Master Version: All versions
Siemens SIMATIC ET200S (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants) Version: 0   < *
Siemens SIMATIC HMI Comfort Panels (incl. SIPLUS variants) Version: 0   < *
Siemens SIMATIC HMI KTP Mobile Panels Version: 0   < *
Siemens SIMATIC PN/PN Coupler Version: All versions < V4.2.1
Siemens SIMATIC PROFINET Driver Version: All versions < V2.1
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions < V4.4.0
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: All versions < V2.0
Siemens SIMATIC S7-1500 Software Controller Version: All versions < V2.0
Siemens SIMATIC S7-300 CPU 314C-2 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 315-2 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 315F-2 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 315T-3 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 317-2 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 317F-2 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 317T-3 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 319-3 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 319F-3 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-400 CPU 412-2 PN V7 Version: 0   < V7.0.3
Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7 Version: 0   < V7.0.3
Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7 Version: 0   < V7.0.3
Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7 Version: 0   < V7.0.3
Siemens SIMATIC S7-400 CPU 416F-3 PN/DP V7 Version: 0   < V7.0.3
Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) Version: 0   < V6.0.9
Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) Version: 0   < *
Siemens SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) Version: All versions < V8.2.2
Siemens SIMATIC TDC CP51M1 Version: 0   < V1.1.8
Siemens SIMATIC TDC CPU555 Version: 0   < V1.1.1
Siemens SIMATIC WinAC RTX 2010 Version: All versions < V2010 SP3
Siemens SIMATIC WinAC RTX F 2010 Version: All versions < V2010 SP3
Siemens SINAMICS DCM Version: All versions < V1.5 HF1
Siemens SINAMICS DCP Version: All versions < V1.3
Siemens SINAMICS G110M V4.7 PN Control Unit Version: All versions < V4.7 SP10 HF5
Siemens SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants) Version: All versions < V4.7 SP10 HF5
Siemens SINAMICS G130 V4.7 Control Unit Version: All versions < 4.8
Siemens SINAMICS G150 Control Unit Version: All versions < 4.8
Siemens SINAMICS GH150 V4.7 Control Unit Version: All versions
Siemens SINAMICS GL150 V4.7 Control Unit Version: All versions
Siemens SINAMICS GM150 V4.7 Control Unit Version: All versions
Siemens SINAMICS S110 Control Unit Version: 0   < *
Siemens SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants) Version: 0   < *
Siemens SINAMICS S150 Control Unit Version: All versions < 4.8
Siemens SINAMICS SL150 V4.7 Control Unit Version: All versions < V4.7 HF33
Siemens SINAMICS SM120 V4.7 Control Unit Version: 0   < *
Siemens SINUMERIK 828D Version: All versions < V4.8 SP5
Siemens SINUMERIK 840D sl Version: All versions < V4.8 SP6
Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.4.0
Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.4.0
Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL Version: 0   < V4.4.0
Siemens SIPLUS ET 200MP IM 155-5 PN ST Version: 0   < *
Siemens SIPLUS ET 200MP IM 155-5 PN ST Version: 0   < *
Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL Version: 0   < *
Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL Version: 0   < *
Siemens SIPLUS ET 200S IM 151-8 PN/DP CPU Version: All versions < V3.2.17
Siemens SIPLUS ET 200S IM 151-8F PN/DP CPU Version: All versions < V3.2.17
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.2
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.2
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.2
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.2
Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Version: 0   < V4.2.2
Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Version: 0   < V4.2.2
Siemens SIPLUS ET 200SP IM 155-6 PN HF TX RAIL Version: 0   < V4.2.2
Siemens SIPLUS ET 200SP IM 155-6 PN ST Version: 0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN ST Version: 0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA Version: 0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA Version: 0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL Version: 0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL Version: 0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL Version: 0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL Version: 0   < *
Siemens SIPLUS NET PN/PN Coupler Version: All versions < V4.2.1
Siemens SIPLUS S7-300 CPU 314C-2 PN/DP Version: All versions < V3.3.17
Siemens SIPLUS S7-300 CPU 315-2 PN/DP Version: All versions < V3.2.17
Siemens SIPLUS S7-300 CPU 315F-2 PN/DP Version: All versions < V3.2.17
Siemens SIPLUS S7-300 CPU 317-2 PN/DP Version: All versions < V3.2.17
Siemens SIPLUS S7-300 CPU 317F-2 PN/DP Version: All versions < V3.2.17
Siemens SIPLUS S7-400 CPU 414-3 PN/DP V7 Version: 0   < V7.0.3
Siemens SIPLUS S7-400 CPU 416-3 PN/DP V7 Version: 0   < V7.0.3
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "dk_standard_ethernet_controller_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:ek-ertec_200_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ek-ertec_200_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:ek-ertec_200p_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ek-ertec_200p_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "4.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cfu_pa",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v1.2.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et200ecopn_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et200ecopn_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et200s_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et200s_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et_200al_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et_200m_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et_200mp_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.3.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et_200pro_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et_200s_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.2.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et_200sp_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_hmi_comfort_outdoor_panels",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.2.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_profinet_driver",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-300_cpu_314_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.2.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-300_cpu_315-2_dp_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.2.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_dp_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-300_cpu_315f-2_dp_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.2.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_dp_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-300_cpu_317-2_dp_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.2.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-300_cpu_317-2_pn\\/dp_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.2.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-300_cpu_319-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-300_cpu_319-3_pn\\/dp_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.2.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-400_cpu_412-2_pn",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v7.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\/dp:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-400_cpu_414-3_pn\\/dp",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v7.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\/dp:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-400_cpu_416-3_pn\\/dp",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "v7.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-400_h_v6_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-400_h_v6_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "v6.0.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v6_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-400_pn\\/dp_v6_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-410_cpu_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-410_cpu_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v8.2.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-1200_cpu",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.4.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-1500_cpu",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-1500_controller",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_tdc_cp51m1_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v1.1.8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_tdc_cpu555_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v1.1.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_winac_rtx_2010",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2010_sp3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_winac_rtx_\\(f\\)_2010",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2010_sp3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_dcm",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v1.5_hf1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_dcp",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v1.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_g110m",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.7_sp10_hf5",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_g120",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.7_sp10_hf5",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_g130",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_g150",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_gh150",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_gl150",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_gm150",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_s110",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_s120",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_sl150",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_sl150",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.7_hf33",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_sm120",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinumerik_828d",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.8_sp5",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinumerik_840d_sl",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.8_sp6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_s7-300_cpu_314:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_s7-300_cpu_314",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.3.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2019-10936",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T14:36:59.481395Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T15:59:12.602Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.253Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.6 Patch 01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CFU PA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200AL IM 157-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-3 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-4 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN: IO-Link Master",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200S (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI KTP Mobile Panels",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/PN Coupler",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PROFINET Driver",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 412-2 PN V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CP51M1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CPU555",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.5 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G110M V4.7 PN Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP10 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP10 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c 4.8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c 4.8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S110 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c 4.8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF33"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET PN/PN Coupler",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices improperly handle large amounts of specially crafted UDP packets.\r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T12:03:55.957Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10936",
    "datePublished": "2019-10-10T00:00:00",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.253Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-28400
Vulnerability from cvelistv5
Published
2021-07-13 11:02
Modified
2024-11-12 12:49
Summary
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
Impacted products
Vendor Product Version
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 Version: All versions
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P Version: All versions < V4.7
Siemens RUGGEDCOM RM1224 LTE(4G) EU Version: 0   < V6.4
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: 0   < V6.4
Siemens SCALANCE M804PB Version: 0   < V6.4
Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V6.4
Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V6.4
Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V6.4
Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V6.4
Siemens SCALANCE M826-2 SHDSL-Router Version: 0   < V6.4
Siemens SCALANCE M874-2 Version: 0   < V6.4
Siemens SCALANCE M874-3 Version: 0   < V6.4
Siemens SCALANCE M874-3 3G-Router (CN) Version: 0   < V6.4
Siemens SCALANCE M876-3 Version: 0   < V6.4
Siemens SCALANCE M876-3 (ROK) Version: 0   < V6.4
Siemens SCALANCE M876-4 Version: 0   < V6.4
Siemens SCALANCE M876-4 (EU) Version: 0   < V6.4
Siemens SCALANCE M876-4 (NAM) Version: 0   < V6.4
Siemens SCALANCE MUM853-1 (A1) Version: 0   < V6.4
Siemens SCALANCE MUM853-1 (B1) Version: 0   < V6.4
Siemens SCALANCE MUM853-1 (EU) Version: 0   < V6.4
Siemens SCALANCE MUM856-1 (A1) Version: 0   < V6.4
Siemens SCALANCE MUM856-1 (B1) Version: 0   < V6.4
Siemens SCALANCE MUM856-1 (CN) Version: 0   < V6.4
Siemens SCALANCE MUM856-1 (EU) Version: 0   < V6.4
Siemens SCALANCE MUM856-1 (RoW) Version: 0   < V6.4
Siemens SCALANCE S615 EEC LAN-Router Version: 0   < V6.4
Siemens SCALANCE S615 LAN-Router Version: 0   < V6.4
Siemens SCALANCE W1748-1 M12 Version: All versions < V3.0.0
Siemens SCALANCE W1748-1 M12 Version: All versions < V3.0.0
Siemens SCALANCE W1788-1 M12 Version: All versions < V3.0.0
Siemens SCALANCE W1788-2 EEC M12 Version: All versions < V3.0.0
Siemens SCALANCE W1788-2 M12 Version: All versions < V3.0.0
Siemens SCALANCE W1788-2IA M12 Version: All versions < V3.0.0
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 EEC Version: All versions
Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE X200-4P IRT Version: All Versions < V5.5.0
Siemens SCALANCE X201-3P IRT Version: All Versions < V5.5.0
Siemens SCALANCE X201-3P IRT PRO Version: All Versions < V5.5.0
Siemens SCALANCE X202-2IRT Version: All Versions < V5.5.0
Siemens SCALANCE X202-2P IRT Version: All Versions < V5.5.0
Siemens SCALANCE X202-2P IRT PRO Version: All Versions < V5.5.0
Siemens SCALANCE X204-2 Version: 0   < V5.2.5
Siemens SCALANCE X204-2FM Version: 0   < V5.2.5
Siemens SCALANCE X204-2LD Version: 0   < V5.2.5
Siemens SCALANCE X204-2LD TS Version: 0   < V5.2.5
Siemens SCALANCE X204-2TS Version: 0   < V5.2.5
Siemens SCALANCE X204IRT Version: All Versions < V5.5.0
Siemens SCALANCE X204IRT PRO Version: All Versions < V5.5.0
Siemens SCALANCE X206-1 Version: 0   < V5.2.5
Siemens SCALANCE X206-1LD Version: 0   < V5.2.5
Siemens SCALANCE X208 Version: 0   < V5.2.5
Siemens SCALANCE X208PRO Version: 0   < V5.2.5
Siemens SCALANCE X212-2 Version: 0   < V5.2.5
Siemens SCALANCE X212-2LD Version: 0   < V5.2.5
Siemens SCALANCE X216 Version: 0   < V5.2.5
Siemens SCALANCE X224 Version: 0   < V5.2.5
Siemens SCALANCE X302-7 EEC (230V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X302-7 EEC (230V) Version: 0   < V4.1.4
Siemens SCALANCE X302-7 EEC (24V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X302-7 EEC (24V) Version: 0   < V4.1.4
Siemens SCALANCE X302-7 EEC (2x 230V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X302-7 EEC (2x 230V) Version: 0   < V4.1.4
Siemens SCALANCE X302-7 EEC (2x 24V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X302-7 EEC (2x 24V) Version: 0   < V4.1.4
Siemens SCALANCE X304-2FE Version: 0   < V4.1.4
Siemens SCALANCE X306-1LD FE Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (230V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (230V) Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (24V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (24V) Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (2x 230V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (2x 230V) Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (2x 24V, coated) Version: 0   < V4.1.4
Siemens SCALANCE X307-2 EEC (2x 24V) Version: 0   < V4.1.4
Siemens SCALANCE X307-3 Version: 0   < V4.1.4
Siemens SCALANCE X307-3 Version: 0   < V4.1.4
Siemens SCALANCE X307-3LD Version: 0   < V4.1.4
Siemens SCALANCE X307-3LD Version: 0   < V4.1.4
Siemens SCALANCE X308-2 Version: 0   < V4.1.4
Siemens SCALANCE X308-2 Version: 0   < V4.1.4
Siemens SCALANCE X308-2LD Version: 0   < V4.1.4
Siemens SCALANCE X308-2LD Version: 0   < V4.1.4
Siemens SCALANCE X308-2LH Version: 0   < V4.1.4
Siemens SCALANCE X308-2LH Version: 0   < V4.1.4
Siemens SCALANCE X308-2LH+ Version: 0   < V4.1.4
Siemens SCALANCE X308-2LH+ Version: 0   < V4.1.4
Siemens SCALANCE X308-2M Version: 0   < V4.1.4
Siemens SCALANCE X308-2M Version: 0   < V4.1.4
Siemens SCALANCE X308-2M PoE Version: 0   < V4.1.4
Siemens SCALANCE X308-2M PoE Version: 0   < V4.1.4
Siemens SCALANCE X308-2M TS Version: 0   < V4.1.4
Siemens SCALANCE X308-2M TS Version: 0   < V4.1.4
Siemens SCALANCE X310 Version: 0   < V4.1.4
Siemens SCALANCE X310 Version: 0   < V4.1.4
Siemens SCALANCE X310FE Version: 0   < V4.1.4
Siemens SCALANCE X310FE Version: 0   < V4.1.4
Siemens SCALANCE X320-1 FE Version: 0   < V4.1.4
Siemens SCALANCE X320-1-2LD FE Version: 0   < V4.1.4
Siemens SCALANCE X408-2 Version: 0   < V4.1.4
Siemens SCALANCE XB205-3 (SC, PN) Version: 0   < V4.3
Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < V4.3
Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < V4.3
Siemens SCALANCE XB205-3 (ST, PN) Version: 0   < V4.3
Siemens SCALANCE XB205-3LD (SC, E/IP) Version: 0   < V4.3
Siemens SCALANCE XB205-3LD (SC, PN) Version: 0   < V4.3
Siemens SCALANCE XB208 (E/IP) Version: 0   < V4.3
Siemens SCALANCE XB208 (PN) Version: 0   < V4.3
Siemens SCALANCE XB213-3 (SC, E/IP) Version: 0   < V4.3
Siemens SCALANCE XB213-3 (SC, PN) Version: 0   < V4.3
Siemens SCALANCE XB213-3 (ST, E/IP) Version: 0   < V4.3
Siemens SCALANCE XB213-3 (ST, PN) Version: 0   < V4.3
Siemens SCALANCE XB213-3LD (SC, E/IP) Version: 0   < V4.3
Siemens SCALANCE XB213-3LD (SC, PN) Version: 0   < V4.3
Siemens SCALANCE XB216 (E/IP) Version: 0   < V4.3
Siemens SCALANCE XB216 (PN) Version: 0   < V4.3
Siemens SCALANCE XC206-2 (SC) Version: 0   < V4.3
Siemens SCALANCE XC206-2 (ST/BFOC) Version: 0   < V4.3
Siemens SCALANCE XC206-2G PoE Version: 0   < V4.3
Siemens SCALANCE XC206-2G PoE (54 V DC) Version: 0   < V4.3
Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: 0   < V4.3
Siemens SCALANCE XC206-2SFP Version: 0   < V4.3
Siemens SCALANCE XC206-2SFP EEC Version: 0   < V4.3
Siemens SCALANCE XC206-2SFP G Version: 0   < V4.3
Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: 0   < V4.3
Siemens SCALANCE XC206-2SFP G EEC Version: 0   < V4.3
Siemens SCALANCE XC208 Version: 0   < V4.3
Siemens SCALANCE XC208EEC Version: 0   < V4.3
Siemens SCALANCE XC208G Version: 0   < V4.3
Siemens SCALANCE XC208G (EIP def.) Version: 0   < V4.3
Siemens SCALANCE XC208G EEC Version: 0   < V4.3
Siemens SCALANCE XC208G PoE Version: 0   < V4.3
Siemens SCALANCE XC208G PoE (54 V DC) Version: 0   < V4.3
Siemens SCALANCE XC216 Version: 0   < V4.3
Siemens SCALANCE XC216-3G PoE Version: 0   < V4.3
Siemens SCALANCE XC216-3G PoE (54 V DC) Version: 0   < V4.3
Siemens SCALANCE XC216-4C Version: 0   < V4.3
Siemens SCALANCE XC216-4C G Version: 0   < V4.3
Siemens SCALANCE XC216-4C G (EIP Def.) Version: 0   < V4.3
Siemens SCALANCE XC216-4C G EEC Version: 0   < V4.3
Siemens SCALANCE XC216EEC Version: 0   < V4.3
Siemens SCALANCE XC224 Version: 0   < V4.3
Siemens SCALANCE XC224-4C G Version: 0   < V4.3
Siemens SCALANCE XC224-4C G (EIP Def.) Version: 0   < V4.3
Siemens SCALANCE XC224-4C G EEC Version: 0   < V4.3
Siemens SCALANCE XF201-3P IRT Version: All Versions < V5.5.0
Siemens SCALANCE XF202-2P IRT Version: All Versions < V5.5.0
Siemens SCALANCE XF204 Version: 0   < V5.2.5
Siemens SCALANCE XF204 Version: 0   < V4.3
Siemens SCALANCE XF204 DNA Version: 0   < V4.3
Siemens SCALANCE XF204-2 Version: 0   < V5.2.5
Siemens SCALANCE XF204-2BA Version: 0   < V4.3
Siemens SCALANCE XF204-2BA DNA Version: 0   < V4.3
Siemens SCALANCE XF204-2BA IRT Version: All Versions < V5.5.0
Siemens SCALANCE XF204IRT Version: All Versions < V5.5.0
Siemens SCALANCE XF206-1 Version: 0   < V5.2.5
Siemens SCALANCE XF208 Version: 0   < V5.2.5
Siemens SCALANCE XM408-4C Version: 0   < V6.3.1
Siemens SCALANCE XM408-4C (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XM408-8C Version: 0   < V6.3.1
Siemens SCALANCE XM408-8C (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XM416-4C Version: 0   < V6.3.1
Siemens SCALANCE XM416-4C (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XP208 Version: 0   < V4.3
Siemens SCALANCE XP208 (Ethernet/IP) Version: 0   < V4.3
Siemens SCALANCE XP208EEC Version: 0   < V4.3
Siemens SCALANCE XP208PoE EEC Version: 0   < V4.3
Siemens SCALANCE XP216 Version: 0   < V4.3
Siemens SCALANCE XP216 (Ethernet/IP) Version: 0   < V4.3
Siemens SCALANCE XP216EEC Version: 0   < V4.3
Siemens SCALANCE XP216POE EEC Version: 0   < V4.3
Siemens SCALANCE XR324-12M (230V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M (230V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M (230V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M (230V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M (24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M (24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M (24V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M (24V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M TS (24V) Version: 0   < V4.1.4
Siemens SCALANCE XR324-12M TS (24V) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (24V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (24V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M PoE (230V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M PoE (230V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M PoE (24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M PoE (24V, ports on rear) Version: 0   < V4.1.4
Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) Version: 0   < V4.1.4
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: 0   < V4.3
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: 0   < V4.3
Siemens SCALANCE XR326-2C PoE WG Version: 0   < V4.3
Siemens SCALANCE XR326-2C PoE WG (without UL) Version: 0   < V4.3
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: 0   < V4.3
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: 0   < V4.3
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < V4.3
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < V4.3
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: 0   < V4.3
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: 0   < V4.3
Siemens SCALANCE XR524-8C, 1x230V Version: 0   < V6.3.1
Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR524-8C, 24V Version: 0   < V6.3.1
Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR524-8C, 2x230V Version: 0   < V6.3.1
Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR526-8C, 1x230V Version: 0   < V6.3.1
Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR526-8C, 24V Version: 0   < V6.3.1
Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR526-8C, 2x230V Version: 0   < V6.3.1
Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR528-6M Version: 0   < V6.3.1
Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR528-6M (2HR2) Version: 0   < V6.3.1
Siemens SCALANCE XR528-6M (L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR552-12M Version: 0   < V6.3.1
Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: 0   < V6.3.1
Siemens SCALANCE XR552-12M (2HR2) Version: 0   < V6.3.1
Siemens SCALANCE XR552-12M (2HR2) Version: 0   < V6.3.1
Siemens SIMATIC CFU DIQ Version: 0   < V2.0.0
Siemens SIMATIC CFU PA Version: 0   < V2.0.0
Siemens SIMATIC CM 1542-1 Version: All versions < V3.0
Siemens SIMATIC CP 1604 Version: All Versions >= V2.7
Siemens SIMATIC CP 1616 Version: All Versions >= V2.7
Siemens SIMATIC CP 1626 Version: All versions
Siemens SIMATIC IE/PB-LINK Version: V3   < *
Siemens SIMATIC MV540 H Version: All versions < V3.0
Siemens SIMATIC MV540 S Version: All versions < V3.0
Siemens SIMATIC MV550 H Version: All versions < V3.0
Siemens SIMATIC MV550 S Version: All versions < V3.0
Siemens SIMATIC MV560 U Version: All versions < V3.0
Siemens SIMATIC MV560 X Version: All versions < V3.0
Siemens SIMATIC NET DK-16xx PN IO Version: All Versions >= V2.7
Siemens SIMATIC Power Line Booster PLB, Base Module Version: All versions
Siemens SIMATIC PROFINET Driver Version: All versions < V2.3
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All Versions < V4.5
Siemens SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants) Version: All versions < V1.1.3
Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) Version: All versions < V2.1.3
Siemens SIPLUS NET SCALANCE X308-2 Version: 0   < V4.1.4
Siemens SIPLUS NET SCALANCE XC206-2 Version: 0   < V4.3
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: 0   < V4.3
Siemens SIPLUS NET SCALANCE XC208 Version: 0   < V4.3
Siemens SIPLUS NET SCALANCE XC216-4C Version: 0   < V4.3
Siemens SOFTNET-IE PNIO Version: All versions
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m812-1_adsl-router_annex_b",
            "vendor": "seimens",
            "versions": [
              {
                "status": "affected",
                "version": "0"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200p:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200p",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.7",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:ruggedcom_rm1224:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ruggedcom_rm1224",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m804pb",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_a:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m812-1_adsl-router_annex_a",
            "vendor": "seimens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m812-1_adsl-router_annex_b",
            "vendor": "seimens",
            "versions": [
              {
                "lessThan": "6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m816_1_adsl_router_annex_a:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m816_1_adsl_router_annex_a",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m816-1_adsl-router_annex_b:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m816-1_adsl-router_annex_b",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m826-2_shdsl-router:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m826-2_shdsl-router",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_m874_2:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_m874_2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_m874_3:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_m874_3",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_3_evdo:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_3_evdo",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_3_rok:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_3_rok",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_4_eu:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_4_eu",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_4_nam:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_4_nam",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_s615",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w700_ieee_802.11n_family:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w700_ieee_802.11n_family",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1748_1_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1748_1_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_1_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_1_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_2_eec_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_2_eec_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_2_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_2_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_2ia_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_2ia_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_x200_4p_irt:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_x200_4p_irt",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_x201_3p_irt:0.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_x201_3p_irt",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_x201_3p_irt_pro:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_x201_3p_irt_pro",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalancce_x202_2p_irt:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalancce_x202_2p_irt",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_202_2p_irt_pro:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_202_2p_irt_pro",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalancce_x204_2:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalancce_x204_2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2fm:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2fm",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2ld:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2ld",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2ld_ts:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2ld_ts",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2ts:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2ts",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-28400",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-13T18:59:11.953107Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-24T18:07:44.485Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:59.218Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3 3G-Router (CN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (A1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (B1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (A1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (B1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (CN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X200-4P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2FM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD TS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2TS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X224",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CFU DIQ",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CFU PA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003e= V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003e= V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1626",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IE/PB-LINK",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV540 H",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV540 S",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV550 H",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV550 S",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV560 U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV560 X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET DK-16xx PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003e= V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Power Line Booster PLB, Base Module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PROFINET Driver",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V4.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SOFTNET-IE PNIO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-12T12:49:20.867Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28400",
    "datePublished": "2021-07-13T11:02:49",
    "dateReserved": "2020-11-10T00:00:00",
    "dateUpdated": "2024-11-12T12:49:20.867Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-25622
Vulnerability from cvelistv5
Published
2022-04-12 00:00
Modified
2024-08-03 04:42
Summary
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
Impacted products
Vendor Product Version
Siemens SIMATIC CFU PA Version: 0   < V2.0.0
Siemens SIMATIC ET 200AL IM 157-1 PN Version: All versions
Siemens SIMATIC ET 200MP IM 155-5 PN HF Version: V4.2.0   < *
Siemens SIMATIC ET 200pro IM 154-8 PN/DP CPU Version: All versions < V3.2.19
Siemens SIMATIC ET 200pro IM 154-8F PN/DP CPU Version: All versions < V3.2.19
Siemens SIMATIC ET 200pro IM 154-8FX PN/DP CPU Version: All versions < V3.2.19
Siemens SIMATIC ET 200S IM 151-8 PN/DP CPU Version: All versions < V3.2.19
Siemens SIMATIC ET 200S IM 151-8F PN/DP CPU Version: All versions < V3.2.19
Siemens SIMATIC ET 200SP IM 155-6 MF HF Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC ET 200SP IM 155-6 PN HF Version: V4.2.0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN/2 HF Version: V4.2.0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN/3 HF Version: V4.2.0   < *
Siemens SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L Version: V5.1.1   < V5.1.2
Siemens SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L Version: All versions >= V5.1.1
Siemens SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L Version: All versions >= V5.1.1
Siemens SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L Version: All versions >= V5.1.1
Siemens SIMATIC ET200ecoPN, DI 16x24VDC, M12-L Version: V5.1.1   < V5.1.2
Siemens SIMATIC ET200ecoPN, DI 8x24VDC, M12-L Version: V5.1.1   < V5.1.2
Siemens SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L Version: V5.1.1   < V5.1.3
Siemens SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L Version: V5.1.1   < V5.1.2
Siemens SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L Version: V5.1.1   < V5.1.2
Siemens SIMATIC PN/MF Coupler Version: All versions
Siemens SIMATIC PN/PN Coupler Version: All versions >= 4.2
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: All versions < V2.0.0
Siemens SIMATIC S7-300 CPU 314C-2 PN/DP Version: All versions < V3.3.19
Siemens SIMATIC S7-300 CPU 315-2 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 315F-2 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 315T-3 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 317-2 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 317F-2 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 317T-3 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 319-3 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 319F-3 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-400 CPU 412-2 PN V7 Version: 0   < *
Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7 Version: 0   < *
Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7 Version: 0   < *
Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7 Version: 0   < *
Siemens SIMATIC S7-400 CPU 416F-3 PN/DP V7 Version: 0   < *
Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) Version: 0   < V6.0.10
Siemens SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) Version: All versions < V10.1.1
Siemens SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) Version: 0   < V8.2.3
Siemens SIMATIC TDC CP51M1 Version: 0   < V1.1.10
Siemens SIMATIC TDC CPU555 Version: 0   < V1.2.1
Siemens SIMATIC WinAC RTX 2010 Version: All versions
Siemens SIMATIC WinAC RTX F 2010 Version: All versions
Siemens SINAMICS DCM Version: 0   < V1.5 SP1
Siemens SINAMICS G110M Version: 0   < V4.7.14
Siemens SINAMICS G115D Version: 0   < V4.7.14
Siemens SINAMICS G120 (incl. SIPLUS variants) Version: 0   < V4.7 SP14
Siemens SINAMICS G130 Version: 0   < V5.2.3.13
Siemens SINAMICS G150 Version: 0   < V5.2.3.13
Siemens SINAMICS S110 Version: 0   < *
Siemens SINAMICS S120 (incl. SIPLUS variants) Version: 0   < V5.2 SP3 HF13
Siemens SINAMICS S150 Version: 0   < V5.2.3.13
Siemens SINAMICS S210 (6SL5...) Version: 0   < V5.2 SP3 HF18
Siemens SINAMICS V90 Version: 0   < V1.04.04
Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: V4.2.0   < *
Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: V4.2.0   < *
Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL Version: V4.2.0   < *
Siemens SIPLUS ET 200S IM 151-8 PN/DP CPU Version: All versions < V3.2.19
Siemens SIPLUS ET 200S IM 151-8F PN/DP CPU Version: All versions < V3.2.19
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: V4.2.0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: V4.2.0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: V4.2.0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: V4.2.0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Version: V4.2.0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Version: V4.2.0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN HF TX RAIL Version: V4.2.0   < *
Siemens SIPLUS HCS4200 CIM4210 Version: All versions
Siemens SIPLUS HCS4200 CIM4210C Version: All versions
Siemens SIPLUS HCS4300 CIM4310 Version: All versions
Siemens SIPLUS NET PN/PN Coupler Version: All versions >= 4.2
Siemens SIPLUS S7-300 CPU 314C-2 PN/DP Version: All versions < V3.3.19
Siemens SIPLUS S7-300 CPU 315-2 PN/DP Version: All versions < V3.2.19
Siemens SIPLUS S7-300 CPU 315F-2 PN/DP Version: All versions < V3.2.19
Siemens SIPLUS S7-300 CPU 317-2 PN/DP Version: All versions < V3.2.19
Siemens SIPLUS S7-300 CPU 317F-2 PN/DP Version: All versions < V3.2.19
Siemens SIPLUS S7-400 CPU 414-3 PN/DP V7 Version: 0   < *
Siemens SIPLUS S7-400 CPU 416-3 PN/DP V7 Version: 0   < *
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:50.341Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CFU DIQ",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CFU PA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200AL IM 157-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V4.2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 MF HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V4.2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V4.2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V4.2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.1.2",
              "status": "affected",
              "version": "V5.1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.1.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.1.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.1.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.1.2",
              "status": "affected",
              "version": "V5.1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.1.2",
              "status": "affected",
              "version": "V5.1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.1.3",
              "status": "affected",
              "version": "V5.1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.1.2",
              "status": "affected",
              "version": "V5.1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.1.2",
              "status": "affected",
              "version": "V5.1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/MF Coupler",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/PN Coupler",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= 4.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 412-2 PN V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V10.1.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CP51M1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CPU555",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.5 SP1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G110M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.7.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G115D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.7.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G120 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.7 SP14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.3.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.3.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S110",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2 SP3 HF13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2.3.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S210 (6SL5...)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.2 SP3 HF18",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS V90",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.04.04",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V4.2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V4.2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V4.2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V4.2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V4.2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V4.2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V4.2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V4.2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V4.2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V4.2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS HCS4200 CIM4210",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS HCS4200 CIM4210C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS HCS4300 CIM4310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET PN/PN Coupler",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= 4.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T12:04:01.924Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-25622",
    "datePublished": "2022-04-12T00:00:00",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:50.341Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}