Search

Find a vulnerability

Search criteria ⓘ Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    1 vulnerability found for Server Technology PRO3X by unknown

    GCVE-1988-2026-0431

    Vulnerability from gna-1988 – Published: 2026-10-02 04:57 – Updated: 2026-10-02 04:57
    VLAI
    Title
    [0day-rubbish] Server Technology PRO3X PDU 030600 port_mux listener program override to root command execution (7.2)
    Summary
    0day Rubbish Research Team is publicly disclosing a vulnerability in Server Technology (Legrand group) PRO3X series intelligent rack PDUs, firmware spdu-pro3x-030600 build 46640 (ARM 32-bit uClibc Linux). Type: authenticated listener program override leading to root command execution (CWE-78, CWE-269; a separate hard-coded factory credential is reported as CWE-798). PRO3X PDUs run port_mux, an inetd-style launcher that starts every protocol listener with fork + execv and never drops privileges, so listeners run as root. The executable path is proto_listener_entry.program in cfg_pmux.cdl, typed nctl_nspc_nempty_str_512, a free-form string with no whitelist, and an authenticated administrator rewrites it through setConfiguration (POST /J/cfg). Pointing the port 80 http listener at /bin/sh with arguments -c "<cmd>" applies at runtime: the next TCP connection to port 80 executes the attacker's command as uid 0. Scoring. This finding is dual-scored, with the conditional figure published alongside the primary: - PRIMARY, 7.2 High, CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. An authenticated administrator is required, and that gate was verified unbypassed. - CONDITIONAL, 9.8 Critical, CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Where the factory default administrator credential is left unchanged, unrotated units are open with no privileged secret. Impact: root (uid 0) on the rack power distribution controller, a critical-infrastructure power monitoring and control appliance. Full configuration control follows; the disabled modbus (502) and mbusd (503) listeners can be armed with attacker-chosen programs. Outlet switching and power cycling were not separately exercised by this proof-of-concept. Authentication: post-authentication administrator (with a shipped default administrator credential reported separately as CWE-798). Verification boundary, stated plainly. No physical PRO3X hardware was used, and the three-step HTTP chain (POST /J/auth, POST /J/cfg, then the TCP trigger) was NOT exercised end to end against a device. What was dynamically proven is the root execution primitive: port_mux fork + execv of an injected /bin/sh -c as uid 0, run twice inside a network namespace under qemu-arm-static against the rootfs unpacked from the firmware Squashfs, each producing a root-owned marker containing uid=0(root). Each link of the HTTP delivery path was confirmed component by component (httpd.conf routing, the BusyBox SCM_RIGHTS descriptor passing, the administrator credential accepted by auth_cli, and the configuration write accepted and read back through cfgc). SCM_RIGHTS descriptor passing between the separate httpd and jsonrpcd processes does not complete under qemu user-mode emulation, which is an emulation-environment limitation rather than a property of the vulnerability. Only this build was tested; no other build or model is claimed. Full technical analysis and a reproducible proof-of-concept: https://0day-rubbish.com/blog/servertech-pro3x-port-mux-command-injection Project archive (ongoing disclosure series): https://github.com/Exploit-Garbage/0day-Rubbish The vendor has been notified through its published security contact. No vulnerability identifier has been assigned to this finding yet. -- 0day Rubbish Research Team disclosure () 0day-rubbish com https://0day-rubbish.com _______________________________________________ Sent through the Full Disclosure mailing list https://nmap.org/mailman/listinfo/fulldisclosure Web Archives & RSS: https://seclists.org/fulldisclosure/
    Severity
    No CVSS data available.
    Assigner
    VULNARCHIVE GNA GNA-1988
    GNA scorecard E 38/100 over 445 records in the last 180 days details
    Impacted products

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "product": "Server Technology PRO3X",
              "vendor": "unknown",
              "versions": [
                {
                  "status": "affected",
                  "version": "unknown"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "disclosure via Fulldisclosure"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "0day Rubbish Research Team is publicly disclosing a vulnerability in Server\nTechnology (Legrand group) PRO3X series intelligent rack PDUs, firmware\nspdu-pro3x-030600 build 46640 (ARM 32-bit uClibc Linux).\n\nType: authenticated listener program override leading to root command execution\n(CWE-78, CWE-269; a separate hard-coded factory credential is reported as\nCWE-798). PRO3X PDUs run port_mux, an inetd-style launcher that starts every\nprotocol listener with fork + execv and never drops privileges, so listeners run\nas root. The executable path is proto_listener_entry.program in cfg_pmux.cdl,\ntyped nctl_nspc_nempty_str_512, a free-form string with no whitelist, and an\nauthenticated administrator rewrites it through setConfiguration (POST /J/cfg).\nPointing the port 80 http listener at /bin/sh with arguments -c \"\u003ccmd\u003e\" applies at\nruntime: the next TCP connection to port 80 executes the attacker\u0027s command as\nuid 0.\n\nScoring. This finding is dual-scored, with the conditional figure published\nalongside the primary:\n- PRIMARY, 7.2 High, CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. An\n  authenticated administrator is required, and that gate was verified unbypassed.\n- CONDITIONAL, 9.8 Critical, CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Where\n  the factory default administrator credential is left unchanged, unrotated units\n  are open with no privileged secret.\n\nImpact: root (uid 0) on the rack power distribution controller, a\ncritical-infrastructure power monitoring and control appliance. Full configuration\ncontrol follows; the disabled modbus (502) and mbusd (503) listeners can be armed\nwith attacker-chosen programs. Outlet switching and power cycling were not\nseparately exercised by this proof-of-concept.\n\nAuthentication: post-authentication administrator (with a shipped default\nadministrator credential reported separately as CWE-798).\n\nVerification boundary, stated plainly. No physical PRO3X hardware was used, and\nthe three-step HTTP chain (POST /J/auth, POST /J/cfg, then the TCP trigger) was\nNOT exercised end to end against a device. What was dynamically proven is the\nroot execution primitive: port_mux fork + execv of an injected /bin/sh -c as uid\n0, run twice inside a network namespace under qemu-arm-static against the\nrootfs unpacked from the firmware Squashfs, each producing a root-owned marker\ncontaining uid=0(root). Each link of the HTTP delivery path was confirmed\ncomponent by component (httpd.conf routing, the BusyBox SCM_RIGHTS descriptor\npassing, the administrator credential accepted by auth_cli, and the configuration\nwrite accepted and read back through cfgc). SCM_RIGHTS descriptor passing between\nthe separate httpd and jsonrpcd processes does not complete under qemu user-mode\nemulation, which is an emulation-environment limitation rather than a property of\nthe vulnerability. Only this build was tested; no other build or model is claimed.\n\nFull technical analysis and a reproducible proof-of-concept:\n  https://0day-rubbish.com/blog/servertech-pro3x-port-mux-command-injection\n\nProject archive (ongoing disclosure series):\n  https://github.com/Exploit-Garbage/0day-Rubbish\n\nThe vendor has been notified through its published security contact. No vulnerability identifier has been assigned to\nthis finding yet.\n\n--\n0day Rubbish Research Team\ndisclosure () 0day-rubbish com\nhttps://0day-rubbish.com\n_______________________________________________\nSent through the Full Disclosure mailing list\nhttps://nmap.org/mailman/listinfo/fulldisclosure\nWeb Archives \u0026 RSS: https://seclists.org/fulldisclosure/"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269",
                  "lang": "en",
                  "type": "CWE"
                },
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78",
                  "lang": "en",
                  "type": "CWE"
                },
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T04:57:33Z",
            "orgId": "4e2abfbf-4a2a-4b76-a4e0-d77c18ba156c",
            "shortName": "VULNARCHIVE"
          },
          "references": [
            {
              "tags": [
                "technical-description",
                "exploit"
              ],
              "url": "https://vuln.freearchive.org/archive/full-disclosure/2026/Sep/79"
            },
            {
              "tags": [
                "technical-description"
              ],
              "url": "https://seclists.org/fulldisclosure/2026/Sep/79"
            },
            {
              "url": "https://0day-rubbish.com"
            },
            {
              "url": "https://0day-rubbish.com/blog/servertech-pro3x-port-mux-command-injection"
            },
            {
              "url": "https://github.com/Exploit-Garbage/0day-Rubbish"
            },
            {
              "url": "https://nmap.org/mailman/listinfo/fulldisclosure"
            },
            {
              "url": "https://seclists.org/fulldisclosure/"
            }
          ],
          "source": {
            "defect": [
              "https://seclists.org/fulldisclosure/2026/Sep/79"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "[0day-rubbish] Server Technology PRO3X PDU 030600 port_mux listener program override to root command execution (7.2)",
          "x_gcve": [
            {
              "recordType": "advisory",
              "relationships": [],
              "vulnId": "GCVE-1988-2026-0431",
              "x_vulnarchive": {
                "archiveUrl": "https://vuln.freearchive.org/archive/full-disclosure/2026/Sep/79",
                "automated": true,
                "contentSha256": "9914d9e5c60c365c9e58406f57ddde29b4945a74adbb372e4574a6056b52e5be",
                "evidenceScore": 11,
                "messageId": "",
                "originalUrl": "https://seclists.org/fulldisclosure/2026/Sep/79",
                "policy": "vulnarchive-1",
                "sourceFormat": "text/html",
                "sourcePublishedAt": "2026-09-23T04:55:27Z"
              }
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4e2abfbf-4a2a-4b76-a4e0-d77c18ba156c",
        "assignerShortName": "VULNARCHIVE",
        "datePublished": "2026-10-02T04:57:33Z",
        "dateUpdated": "2026-10-02T04:57:33Z",
        "state": "PUBLISHED",
        "vulnId": "GCVE-1988-2026-0431"
      },
      "dataType": "CVE_RECORD",