Search criteria
78 vulnerabilities found for Teamcenter Visualization V14.0 by Siemens
CVE-2023-38076 (GCVE-0-2023-38076)
Vulnerability from cvelistv5 – Published: 2023-09-12 09:32 – Updated: 2024-08-02 17:30
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21041)
Severity ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.1
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:13.747Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21041)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:28.851Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38076",
"datePublished": "2023-09-12T09:32:20.160Z",
"dateReserved": "2023-07-12T13:18:53.823Z",
"dateUpdated": "2024-08-02T17:30:13.747Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38075 (GCVE-0-2023-38075)
Vulnerability from cvelistv5 – Published: 2023-09-12 09:32 – Updated: 2024-08-02 17:30
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20842)
Severity ?
CWE
- CWE-416 - Use After Free
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.1
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:13.592Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20842)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416: Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:27.558Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38075",
"datePublished": "2023-09-12T09:32:19.039Z",
"dateReserved": "2023-07-12T13:18:53.823Z",
"dateUpdated": "2024-08-02T17:30:13.592Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38074 (GCVE-0-2023-38074)
Vulnerability from cvelistv5 – Published: 2023-09-12 09:32 – Updated: 2024-08-02 17:30
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20840)
Severity ?
CWE
- CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.1
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:14.057Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20840)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-843",
"description": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:26.239Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38074",
"datePublished": "2023-09-12T09:32:17.948Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-08-02T17:30:14.057Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38073 (GCVE-0-2023-38073)
Vulnerability from cvelistv5 – Published: 2023-09-12 09:32 – Updated: 2024-08-02 17:30
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20826)
Severity ?
CWE
- CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.1
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:14.105Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20826)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-843",
"description": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:24.893Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38073",
"datePublished": "2023-09-12T09:32:16.855Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-08-02T17:30:14.105Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38072 (GCVE-0-2023-38072)
Vulnerability from cvelistv5 – Published: 2023-09-12 09:32 – Updated: 2024-08-02 17:30
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20825)
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.1
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:13.939Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20825)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:23.586Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38072",
"datePublished": "2023-09-12T09:32:15.739Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-08-02T17:30:13.939Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38071 (GCVE-0-2023-38071)
Vulnerability from cvelistv5 – Published: 2023-09-12 09:32 – Updated: 2024-11-25 21:17
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20824)
Severity ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.1
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:13.596Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-38071",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-25T21:17:44.338467Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-25T21:17:56.790Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20824)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:22.297Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38071",
"datePublished": "2023-09-12T09:32:14.673Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-11-25T21:17:56.790Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38070 (GCVE-0-2023-38070)
Vulnerability from cvelistv5 – Published: 2023-09-12 09:32 – Updated: 2024-08-02 17:30
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20818)
Severity ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.1
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:14.028Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20818)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:21.001Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38070",
"datePublished": "2023-09-12T09:32:13.603Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-08-02T17:30:14.028Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-33124 (GCVE-0-2023-33124)
Vulnerability from cvelistv5 – Published: 2023-06-13 08:17 – Updated: 2025-01-03 01:37
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain a memory corruption vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.2.0.3
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:39:35.997Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-33124",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T01:36:55.445166Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T01:37:31.531Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.0.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.3), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.13), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.10), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.6), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.8), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.3). The affected applications contain a memory corruption vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T08:17:17.687Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-33124",
"datePublished": "2023-06-13T08:17:17.687Z",
"dateReserved": "2023-05-17T13:17:47.573Z",
"dateUpdated": "2025-01-03T01:37:31.531Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-33123 (GCVE-0-2023-33123)
Vulnerability from cvelistv5 – Published: 2023-06-13 08:17 – Updated: 2025-01-03 01:38
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.2.0.3
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:39:35.988Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-33123",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T01:37:56.343806Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T01:38:42.204Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.0.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.3), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.13), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.10), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.6), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.8), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T08:17:16.585Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-33123",
"datePublished": "2023-06-13T08:17:16.585Z",
"dateReserved": "2023-05-17T13:17:47.573Z",
"dateUpdated": "2025-01-03T01:38:42.204Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-33122 (GCVE-0-2023-33122)
Vulnerability from cvelistv5 – Published: 2023-06-13 08:17 – Updated: 2025-01-03 01:40
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted CGM file. This vulnerability could allow an attacker to disclose sensitive information.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.2.0.3
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:39:34.343Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-33122",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T01:40:14.247239Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T01:40:43.732Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.0.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.3), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.13), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.10), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.6), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.8), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted CGM file. This vulnerability could allow an attacker to disclose sensitive information."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T08:17:15.483Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-33122",
"datePublished": "2023-06-13T08:17:15.483Z",
"dateReserved": "2023-05-17T13:17:47.573Z",
"dateUpdated": "2025-01-03T01:40:43.732Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-33121 (GCVE-0-2023-33121)
Vulnerability from cvelistv5 – Published: 2023-06-13 08:17 – Updated: 2025-01-03 01:42
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Severity ?
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.2.0.3
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:39:35.930Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-33121",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T01:41:54.698537Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T01:42:09.311Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.0.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.3), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.13), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.10), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.6), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.8), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.3). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T08:17:14.419Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-33121",
"datePublished": "2023-06-13T08:17:14.419Z",
"dateReserved": "2023-05-17T13:17:47.573Z",
"dateUpdated": "2025-01-03T01:42:09.311Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-3161 (GCVE-0-2022-3161)
Vulnerability from cvelistv5 – Published: 2023-01-13 00:17 – Updated: 2025-01-16 22:01
VLAI?
Summary
The APDFL.dll contains a memory corruption vulnerability while parsing
specially crafted PDF files. This could allow an attacker to execute
code in the context of the current process.
Severity ?
7.8 (High)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < 14.1.0.5
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
Credits
Michael Heinz and Nafiez reported these vulnerabilities to Siemens.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:00:10.551Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3161",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:32:28.959429Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T22:01:39.070Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "JT2Go",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "13.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.0.0.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Michael Heinz and Nafiez reported these vulnerabilities to Siemens.\u00a0"
}
],
"datePublic": "2022-12-16T00:15:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\nThe APDFL.dll contains a memory corruption vulnerability while parsing \nspecially crafted PDF files. This could allow an attacker to execute \ncode in the context of the current process.\n\n\n\n\n\n"
}
],
"value": "\n\nThe APDFL.dll contains a memory corruption vulnerability while parsing \nspecially crafted PDF files. This could allow an attacker to execute \ncode in the context of the current process.\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-13T00:17:06.310Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\nSiemens released updates for the affected products and recommends updating to the latest versions:\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eJT2Go: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u0026nbsp;\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V13.3: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V13.3.0.8 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.0: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.0.0.4 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.1: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003c/span\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Siemens released updates for the affected products and recommends updating to the latest versions:\n * JT2Go: Update to V14.1.0.5 or later version https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html .\u00a0\n\n * Teamcenter Visualization V13.3: Update to V13.3.0.8 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.0: Update to V14.0.0.4 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.1: Update to V14.1.0.5 or later version https://support.sw.siemens.com/ .\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\u003cp\u003eSiemens identified the following specific workaround and mitigation user can apply to reduce risk: \u003c/p\u003e\n\n\u003cul\u003e\u003cli\u003eDo not open untrusted PDF files in JT2Go and Teamcenter Visualization.\u003c/li\u003e\n\u003c/ul\u003e\u003cp\u003eAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\"\u003eoperational guidelines for industrial security\u003c/a\u003e\u003c/p\u003e and following the recommendations in the product manuals. Siemens also provides \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eadditional information on industrial security\u003c/a\u003e.\u003cbr\u003e\nFor further inquiries on security vulnerabilities in Siemens products, users should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\"\u003eSiemens\u003c/a\u003e. \u003cbr\u003e\nFor more information, see the associated Siemens security advisory SSA-360681 in \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\"\u003eHTML \u003c/a\u003eand \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\"\u003eCSAF\u003c/a\u003e.\n\n\u003cbr\u003e"
}
],
"value": "Siemens identified the following specific workaround and mitigation user can apply to reduce risk: \n\n\n\n * Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.\n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security \n\n and following the recommendations in the product manuals. Siemens also provides additional information on industrial security https://www.siemens.com/industrialsecurity .\n\nFor further inquiries on security vulnerabilities in Siemens products, users should contact Siemens https://www.siemens.com/cert/advisories . \n\nFor more information, see the associated Siemens security advisory SSA-360681 in HTML https://cert-portal.siemens.com/productcert/html/ssa-360681.html and CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json .\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-3161",
"datePublished": "2023-01-13T00:17:06.310Z",
"dateReserved": "2022-09-07T23:38:34.248Z",
"dateUpdated": "2025-01-16T22:01:39.070Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-3160 (GCVE-0-2022-3160)
Vulnerability from cvelistv5 – Published: 2023-01-13 00:16 – Updated: 2025-01-16 22:01
VLAI?
Summary
The APDFL.dll contains an out-of-bounds write past the fixed-length
heap-based buffer while parsing specially crafted PDF files. This could
allow an attacker to execute code in the context of the current process.
Severity ?
7.8 (High)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < 14.1.0.5
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
Credits
Michael Heinz and Nafiez reported these vulnerabilities to Siemens.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:00:10.258Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3160",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:32:32.555490Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T22:01:46.182Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "JT2Go",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "13.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.0.0.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Michael Heinz and Nafiez reported these vulnerabilities to Siemens.\u00a0"
}
],
"datePublic": "2022-12-16T00:15:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nThe APDFL.dll contains an out-of-bounds write past the fixed-length \nheap-based buffer while parsing specially crafted PDF files. This could \nallow an attacker to execute code in the context of the current process.\n\n\n\n"
}
],
"value": "\nThe APDFL.dll contains an out-of-bounds write past the fixed-length \nheap-based buffer while parsing specially crafted PDF files. This could \nallow an attacker to execute code in the context of the current process.\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-13T00:16:30.069Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\nSiemens released updates for the affected products and recommends updating to the latest versions:\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eJT2Go: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u0026nbsp;\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V13.3: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V13.3.0.8 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.0: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.0.0.4 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.1: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003c/span\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Siemens released updates for the affected products and recommends updating to the latest versions:\n * JT2Go: Update to V14.1.0.5 or later version https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html .\u00a0\n\n * Teamcenter Visualization V13.3: Update to V13.3.0.8 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.0: Update to V14.0.0.4 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.1: Update to V14.1.0.5 or later version https://support.sw.siemens.com/ .\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\u003cp\u003eSiemens identified the following specific workaround and mitigation user can apply to reduce risk: \u003c/p\u003e\n\n\u003cul\u003e\u003cli\u003eDo not open untrusted PDF files in JT2Go and Teamcenter Visualization.\u003c/li\u003e\n\u003c/ul\u003e\u003cp\u003eAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\"\u003eoperational guidelines for industrial security\u003c/a\u003e\u003c/p\u003e and following the recommendations in the product manuals. Siemens also provides \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eadditional information on industrial security\u003c/a\u003e.\u003cbr\u003e\nFor further inquiries on security vulnerabilities in Siemens products, users should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\"\u003eSiemens\u003c/a\u003e. \u003cbr\u003e\nFor more information, see the associated Siemens security advisory SSA-360681 in \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\"\u003eHTML \u003c/a\u003eand \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\"\u003eCSAF\u003c/a\u003e.\n\n\u003cbr\u003e"
}
],
"value": "Siemens identified the following specific workaround and mitigation user can apply to reduce risk: \n\n\n\n * Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.\n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security \n\n and following the recommendations in the product manuals. Siemens also provides additional information on industrial security https://www.siemens.com/industrialsecurity .\n\nFor further inquiries on security vulnerabilities in Siemens products, users should contact Siemens https://www.siemens.com/cert/advisories . \n\nFor more information, see the associated Siemens security advisory SSA-360681 in HTML https://cert-portal.siemens.com/productcert/html/ssa-360681.html and CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json .\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-3160",
"datePublished": "2023-01-13T00:16:30.069Z",
"dateReserved": "2022-09-07T23:37:57.515Z",
"dateUpdated": "2025-01-16T22:01:46.182Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-3159 (GCVE-0-2022-3159)
Vulnerability from cvelistv5 – Published: 2023-01-13 00:15 – Updated: 2025-01-16 22:01
VLAI?
Summary
The APDFL.dll contains a stack-based buffer overflow vulnerability that
could be triggered while parsing specially crafted PDF files. This could
allow an attacker to execute code in the context of the current
process.
Severity ?
7.8 (High)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < 14.1.0.5
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
Credits
Michael Heinz and Nafiez reported these vulnerabilities to Siemens.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:00:10.535Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3159",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:32:35.727245Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T22:01:53.147Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "JT2Go",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "13.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.0.0.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Michael Heinz and Nafiez reported these vulnerabilities to Siemens.\u00a0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\nThe APDFL.dll contains a stack-based buffer overflow vulnerability that \ncould be triggered while parsing specially crafted PDF files. This could\n allow an attacker to execute code in the context of the current \nprocess.\n\n"
}
],
"value": "The APDFL.dll contains a stack-based buffer overflow vulnerability that \ncould be triggered while parsing specially crafted PDF files. This could\n allow an attacker to execute code in the context of the current \nprocess.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 ",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-13T00:15:15.775Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\nSiemens released updates for the affected products and recommends updating to the latest versions:\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eJT2Go: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u0026nbsp;\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V13.3: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V13.3.0.8 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.0: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.0.0.4 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.1: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003c/span\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Siemens released updates for the affected products and recommends updating to the latest versions:\n * JT2Go: Update to V14.1.0.5 or later version https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html .\u00a0\n\n * Teamcenter Visualization V13.3: Update to V13.3.0.8 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.0: Update to V14.0.0.4 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.1: Update to V14.1.0.5 or later version https://support.sw.siemens.com/ .\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\u003cp\u003eSiemens identified the following specific workaround and mitigation user can apply to reduce risk: \u003c/p\u003e\n\n\u003cul\u003e\u003cli\u003eDo not open untrusted PDF files in JT2Go and Teamcenter Visualization.\u003c/li\u003e\n\u003c/ul\u003e\u003cp\u003eAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\"\u003eoperational guidelines for industrial security\u003c/a\u003e\u003c/p\u003e and following the recommendations in the product manuals. Siemens also provides \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eadditional information on industrial security\u003c/a\u003e.\u003cbr\u003e\nFor further inquiries on security vulnerabilities in Siemens products, users should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\"\u003eSiemens\u003c/a\u003e. \u003cbr\u003e\nFor more information, see the associated Siemens security advisory SSA-360681 in \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\"\u003eHTML \u003c/a\u003eand \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\"\u003eCSAF\u003c/a\u003e.\n\n\u003cbr\u003e"
}
],
"value": "Siemens identified the following specific workaround and mitigation user can apply to reduce risk: \n\n\n\n * Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.\n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security \n\n and following the recommendations in the product manuals. Siemens also provides additional information on industrial security https://www.siemens.com/industrialsecurity .\n\nFor further inquiries on security vulnerabilities in Siemens products, users should contact Siemens https://www.siemens.com/cert/advisories . \n\nFor more information, see the associated Siemens security advisory SSA-360681 in HTML https://cert-portal.siemens.com/productcert/html/ssa-360681.html and CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json .\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-3159",
"datePublished": "2023-01-13T00:15:15.775Z",
"dateReserved": "2022-09-07T23:36:59.702Z",
"dateUpdated": "2025-01-16T22:01:53.147Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-41278 (GCVE-0-2022-41278)
Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2024-08-03 12:42
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Severity ?
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.1.0.6
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:42:45.639Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.0.0.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.1.0.6), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.12), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.8), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.4), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:02:38.189Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-41278",
"datePublished": "2022-12-13T00:00:00",
"dateReserved": "2022-09-21T00:00:00",
"dateUpdated": "2024-08-03T12:42:45.639Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38076 (GCVE-0-2023-38076)
Vulnerability from nvd – Published: 2023-09-12 09:32 – Updated: 2024-08-02 17:30
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21041)
Severity ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.1
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:13.747Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21041)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:28.851Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38076",
"datePublished": "2023-09-12T09:32:20.160Z",
"dateReserved": "2023-07-12T13:18:53.823Z",
"dateUpdated": "2024-08-02T17:30:13.747Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38075 (GCVE-0-2023-38075)
Vulnerability from nvd – Published: 2023-09-12 09:32 – Updated: 2024-08-02 17:30
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20842)
Severity ?
CWE
- CWE-416 - Use After Free
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.1
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:13.592Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20842)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416: Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:27.558Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38075",
"datePublished": "2023-09-12T09:32:19.039Z",
"dateReserved": "2023-07-12T13:18:53.823Z",
"dateUpdated": "2024-08-02T17:30:13.592Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38074 (GCVE-0-2023-38074)
Vulnerability from nvd – Published: 2023-09-12 09:32 – Updated: 2024-08-02 17:30
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20840)
Severity ?
CWE
- CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.1
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:14.057Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20840)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-843",
"description": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:26.239Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38074",
"datePublished": "2023-09-12T09:32:17.948Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-08-02T17:30:14.057Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38073 (GCVE-0-2023-38073)
Vulnerability from nvd – Published: 2023-09-12 09:32 – Updated: 2024-08-02 17:30
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20826)
Severity ?
CWE
- CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.1
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:14.105Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20826)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-843",
"description": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:24.893Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38073",
"datePublished": "2023-09-12T09:32:16.855Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-08-02T17:30:14.105Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38072 (GCVE-0-2023-38072)
Vulnerability from nvd – Published: 2023-09-12 09:32 – Updated: 2024-08-02 17:30
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20825)
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.1
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:13.939Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20825)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:23.586Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38072",
"datePublished": "2023-09-12T09:32:15.739Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-08-02T17:30:13.939Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38071 (GCVE-0-2023-38071)
Vulnerability from nvd – Published: 2023-09-12 09:32 – Updated: 2024-11-25 21:17
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20824)
Severity ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.1
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:13.596Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-38071",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-25T21:17:44.338467Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-25T21:17:56.790Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20824)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:22.297Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38071",
"datePublished": "2023-09-12T09:32:14.673Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-11-25T21:17:56.790Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38070 (GCVE-0-2023-38070)
Vulnerability from nvd – Published: 2023-09-12 09:32 – Updated: 2024-08-02 17:30
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20818)
Severity ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.3.0.1
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:14.028Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20818)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:21.001Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38070",
"datePublished": "2023-09-12T09:32:13.603Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-08-02T17:30:14.028Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-33124 (GCVE-0-2023-33124)
Vulnerability from nvd – Published: 2023-06-13 08:17 – Updated: 2025-01-03 01:37
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain a memory corruption vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.2.0.3
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:39:35.997Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-33124",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T01:36:55.445166Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T01:37:31.531Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.0.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.3), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.13), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.10), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.6), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.8), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.3). The affected applications contain a memory corruption vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T08:17:17.687Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-33124",
"datePublished": "2023-06-13T08:17:17.687Z",
"dateReserved": "2023-05-17T13:17:47.573Z",
"dateUpdated": "2025-01-03T01:37:31.531Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-33123 (GCVE-0-2023-33123)
Vulnerability from nvd – Published: 2023-06-13 08:17 – Updated: 2025-01-03 01:38
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.2.0.3
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:39:35.988Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-33123",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T01:37:56.343806Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T01:38:42.204Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.0.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.3), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.13), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.10), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.6), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.8), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T08:17:16.585Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-33123",
"datePublished": "2023-06-13T08:17:16.585Z",
"dateReserved": "2023-05-17T13:17:47.573Z",
"dateUpdated": "2025-01-03T01:38:42.204Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-33122 (GCVE-0-2023-33122)
Vulnerability from nvd – Published: 2023-06-13 08:17 – Updated: 2025-01-03 01:40
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted CGM file. This vulnerability could allow an attacker to disclose sensitive information.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.2.0.3
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:39:34.343Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-33122",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T01:40:14.247239Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T01:40:43.732Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.0.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.3), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.13), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.10), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.6), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.8), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted CGM file. This vulnerability could allow an attacker to disclose sensitive information."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T08:17:15.483Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-33122",
"datePublished": "2023-06-13T08:17:15.483Z",
"dateReserved": "2023-05-17T13:17:47.573Z",
"dateUpdated": "2025-01-03T01:40:43.732Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-33121 (GCVE-0-2023-33121)
Vulnerability from nvd – Published: 2023-06-13 08:17 – Updated: 2025-01-03 01:42
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Severity ?
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.2.0.3
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:39:35.930Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-33121",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T01:41:54.698537Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T01:42:09.311Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.0.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.3), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.13), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.10), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.6), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.8), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.3). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T08:17:14.419Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-33121",
"datePublished": "2023-06-13T08:17:14.419Z",
"dateReserved": "2023-05-17T13:17:47.573Z",
"dateUpdated": "2025-01-03T01:42:09.311Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-3161 (GCVE-0-2022-3161)
Vulnerability from nvd – Published: 2023-01-13 00:17 – Updated: 2025-01-16 22:01
VLAI?
Summary
The APDFL.dll contains a memory corruption vulnerability while parsing
specially crafted PDF files. This could allow an attacker to execute
code in the context of the current process.
Severity ?
7.8 (High)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < 14.1.0.5
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
Credits
Michael Heinz and Nafiez reported these vulnerabilities to Siemens.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:00:10.551Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3161",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:32:28.959429Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T22:01:39.070Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "JT2Go",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "13.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.0.0.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Michael Heinz and Nafiez reported these vulnerabilities to Siemens.\u00a0"
}
],
"datePublic": "2022-12-16T00:15:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\nThe APDFL.dll contains a memory corruption vulnerability while parsing \nspecially crafted PDF files. This could allow an attacker to execute \ncode in the context of the current process.\n\n\n\n\n\n"
}
],
"value": "\n\nThe APDFL.dll contains a memory corruption vulnerability while parsing \nspecially crafted PDF files. This could allow an attacker to execute \ncode in the context of the current process.\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-13T00:17:06.310Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\nSiemens released updates for the affected products and recommends updating to the latest versions:\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eJT2Go: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u0026nbsp;\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V13.3: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V13.3.0.8 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.0: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.0.0.4 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.1: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003c/span\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Siemens released updates for the affected products and recommends updating to the latest versions:\n * JT2Go: Update to V14.1.0.5 or later version https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html .\u00a0\n\n * Teamcenter Visualization V13.3: Update to V13.3.0.8 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.0: Update to V14.0.0.4 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.1: Update to V14.1.0.5 or later version https://support.sw.siemens.com/ .\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\u003cp\u003eSiemens identified the following specific workaround and mitigation user can apply to reduce risk: \u003c/p\u003e\n\n\u003cul\u003e\u003cli\u003eDo not open untrusted PDF files in JT2Go and Teamcenter Visualization.\u003c/li\u003e\n\u003c/ul\u003e\u003cp\u003eAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\"\u003eoperational guidelines for industrial security\u003c/a\u003e\u003c/p\u003e and following the recommendations in the product manuals. Siemens also provides \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eadditional information on industrial security\u003c/a\u003e.\u003cbr\u003e\nFor further inquiries on security vulnerabilities in Siemens products, users should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\"\u003eSiemens\u003c/a\u003e. \u003cbr\u003e\nFor more information, see the associated Siemens security advisory SSA-360681 in \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\"\u003eHTML \u003c/a\u003eand \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\"\u003eCSAF\u003c/a\u003e.\n\n\u003cbr\u003e"
}
],
"value": "Siemens identified the following specific workaround and mitigation user can apply to reduce risk: \n\n\n\n * Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.\n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security \n\n and following the recommendations in the product manuals. Siemens also provides additional information on industrial security https://www.siemens.com/industrialsecurity .\n\nFor further inquiries on security vulnerabilities in Siemens products, users should contact Siemens https://www.siemens.com/cert/advisories . \n\nFor more information, see the associated Siemens security advisory SSA-360681 in HTML https://cert-portal.siemens.com/productcert/html/ssa-360681.html and CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json .\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-3161",
"datePublished": "2023-01-13T00:17:06.310Z",
"dateReserved": "2022-09-07T23:38:34.248Z",
"dateUpdated": "2025-01-16T22:01:39.070Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-3160 (GCVE-0-2022-3160)
Vulnerability from nvd – Published: 2023-01-13 00:16 – Updated: 2025-01-16 22:01
VLAI?
Summary
The APDFL.dll contains an out-of-bounds write past the fixed-length
heap-based buffer while parsing specially crafted PDF files. This could
allow an attacker to execute code in the context of the current process.
Severity ?
7.8 (High)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < 14.1.0.5
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
Credits
Michael Heinz and Nafiez reported these vulnerabilities to Siemens.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:00:10.258Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3160",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:32:32.555490Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T22:01:46.182Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "JT2Go",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "13.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.0.0.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Michael Heinz and Nafiez reported these vulnerabilities to Siemens.\u00a0"
}
],
"datePublic": "2022-12-16T00:15:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nThe APDFL.dll contains an out-of-bounds write past the fixed-length \nheap-based buffer while parsing specially crafted PDF files. This could \nallow an attacker to execute code in the context of the current process.\n\n\n\n"
}
],
"value": "\nThe APDFL.dll contains an out-of-bounds write past the fixed-length \nheap-based buffer while parsing specially crafted PDF files. This could \nallow an attacker to execute code in the context of the current process.\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-13T00:16:30.069Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\nSiemens released updates for the affected products and recommends updating to the latest versions:\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eJT2Go: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u0026nbsp;\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V13.3: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V13.3.0.8 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.0: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.0.0.4 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.1: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003c/span\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Siemens released updates for the affected products and recommends updating to the latest versions:\n * JT2Go: Update to V14.1.0.5 or later version https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html .\u00a0\n\n * Teamcenter Visualization V13.3: Update to V13.3.0.8 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.0: Update to V14.0.0.4 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.1: Update to V14.1.0.5 or later version https://support.sw.siemens.com/ .\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\u003cp\u003eSiemens identified the following specific workaround and mitigation user can apply to reduce risk: \u003c/p\u003e\n\n\u003cul\u003e\u003cli\u003eDo not open untrusted PDF files in JT2Go and Teamcenter Visualization.\u003c/li\u003e\n\u003c/ul\u003e\u003cp\u003eAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\"\u003eoperational guidelines for industrial security\u003c/a\u003e\u003c/p\u003e and following the recommendations in the product manuals. Siemens also provides \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eadditional information on industrial security\u003c/a\u003e.\u003cbr\u003e\nFor further inquiries on security vulnerabilities in Siemens products, users should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\"\u003eSiemens\u003c/a\u003e. \u003cbr\u003e\nFor more information, see the associated Siemens security advisory SSA-360681 in \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\"\u003eHTML \u003c/a\u003eand \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\"\u003eCSAF\u003c/a\u003e.\n\n\u003cbr\u003e"
}
],
"value": "Siemens identified the following specific workaround and mitigation user can apply to reduce risk: \n\n\n\n * Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.\n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security \n\n and following the recommendations in the product manuals. Siemens also provides additional information on industrial security https://www.siemens.com/industrialsecurity .\n\nFor further inquiries on security vulnerabilities in Siemens products, users should contact Siemens https://www.siemens.com/cert/advisories . \n\nFor more information, see the associated Siemens security advisory SSA-360681 in HTML https://cert-portal.siemens.com/productcert/html/ssa-360681.html and CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json .\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-3160",
"datePublished": "2023-01-13T00:16:30.069Z",
"dateReserved": "2022-09-07T23:37:57.515Z",
"dateUpdated": "2025-01-16T22:01:46.182Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-3159 (GCVE-0-2022-3159)
Vulnerability from nvd – Published: 2023-01-13 00:15 – Updated: 2025-01-16 22:01
VLAI?
Summary
The APDFL.dll contains a stack-based buffer overflow vulnerability that
could be triggered while parsing specially crafted PDF files. This could
allow an attacker to execute code in the context of the current
process.
Severity ?
7.8 (High)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < 14.1.0.5
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
Credits
Michael Heinz and Nafiez reported these vulnerabilities to Siemens.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:00:10.535Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3159",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:32:35.727245Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T22:01:53.147Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "JT2Go",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "13.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.0.0.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens\u00a0",
"versions": [
{
"lessThan": "14.1.0.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Michael Heinz and Nafiez reported these vulnerabilities to Siemens.\u00a0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\nThe APDFL.dll contains a stack-based buffer overflow vulnerability that \ncould be triggered while parsing specially crafted PDF files. This could\n allow an attacker to execute code in the context of the current \nprocess.\n\n"
}
],
"value": "The APDFL.dll contains a stack-based buffer overflow vulnerability that \ncould be triggered while parsing specially crafted PDF files. This could\n allow an attacker to execute code in the context of the current \nprocess.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 ",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-13T00:15:15.775Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\nSiemens released updates for the affected products and recommends updating to the latest versions:\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eJT2Go: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u0026nbsp;\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V13.3: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V13.3.0.8 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.0: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.0.0.4 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.1: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003c/span\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Siemens released updates for the affected products and recommends updating to the latest versions:\n * JT2Go: Update to V14.1.0.5 or later version https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html .\u00a0\n\n * Teamcenter Visualization V13.3: Update to V13.3.0.8 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.0: Update to V14.0.0.4 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.1: Update to V14.1.0.5 or later version https://support.sw.siemens.com/ .\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\u003cp\u003eSiemens identified the following specific workaround and mitigation user can apply to reduce risk: \u003c/p\u003e\n\n\u003cul\u003e\u003cli\u003eDo not open untrusted PDF files in JT2Go and Teamcenter Visualization.\u003c/li\u003e\n\u003c/ul\u003e\u003cp\u003eAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\"\u003eoperational guidelines for industrial security\u003c/a\u003e\u003c/p\u003e and following the recommendations in the product manuals. Siemens also provides \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eadditional information on industrial security\u003c/a\u003e.\u003cbr\u003e\nFor further inquiries on security vulnerabilities in Siemens products, users should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\"\u003eSiemens\u003c/a\u003e. \u003cbr\u003e\nFor more information, see the associated Siemens security advisory SSA-360681 in \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\"\u003eHTML \u003c/a\u003eand \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\"\u003eCSAF\u003c/a\u003e.\n\n\u003cbr\u003e"
}
],
"value": "Siemens identified the following specific workaround and mitigation user can apply to reduce risk: \n\n\n\n * Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.\n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security \n\n and following the recommendations in the product manuals. Siemens also provides additional information on industrial security https://www.siemens.com/industrialsecurity .\n\nFor further inquiries on security vulnerabilities in Siemens products, users should contact Siemens https://www.siemens.com/cert/advisories . \n\nFor more information, see the associated Siemens security advisory SSA-360681 in HTML https://cert-portal.siemens.com/productcert/html/ssa-360681.html and CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json .\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-3159",
"datePublished": "2023-01-13T00:15:15.775Z",
"dateReserved": "2022-09-07T23:36:59.702Z",
"dateUpdated": "2025-01-16T22:01:53.147Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-41278 (GCVE-0-2022-41278)
Vulnerability from nvd – Published: 2022-12-13 00:00 – Updated: 2024-08-03 12:42
VLAI?
Summary
A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Severity ?
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V14.1.0.6
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:42:45.639Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.0.0.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.1.0.6), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.12), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.8), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.4), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:02:38.189Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-41278",
"datePublished": "2022-12-13T00:00:00",
"dateReserved": "2022-09-21T00:00:00",
"dateUpdated": "2024-08-03T12:42:45.639Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}