cve-2022-3159
Vulnerability from cvelistv5
Published
2023-01-13 00:15
Modified
2025-01-16 22:01
Severity ?
EPSS score ?
Summary
The APDFL.dll contains a stack-based buffer overflow vulnerability that
could be triggered while parsing specially crafted PDF files. This could
allow an attacker to execute code in the context of the current
process.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json | Third Party Advisory | |
ics-cert@hq.dhs.gov | https://cert-portal.siemens.com/productcert/html/ssa-360681.html | Patch, Third Party Advisory | |
ics-cert@hq.dhs.gov | https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-360681.html | Patch, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | JT2Go |
Version: 0 < 14.1.0.5 |
||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T01:00:10.535Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_transferred", ], url: "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/html/ssa-360681.html", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json", }, ], title: "CVE Program Container", }, { metrics: [ { other: { content: { id: "CVE-2022-3159", options: [ { Exploitation: "none", }, { Automatable: "no", }, { "Technical Impact": "total", }, ], role: "CISA Coordinator", timestamp: "2025-01-16T20:32:35.727245Z", version: "2.0.3", }, type: "ssvc", }, }, ], providerMetadata: { dateUpdated: "2025-01-16T22:01:53.147Z", orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0", shortName: "CISA-ADP", }, title: "CISA ADP Vulnrichment", }, ], cna: { affected: [ { defaultStatus: "unaffected", product: "JT2Go", vendor: "Siemens ", versions: [ { lessThan: "14.1.0.5", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unaffected", product: "Teamcenter Visualization V13.3", vendor: "Siemens ", versions: [ { lessThan: "13.3.0.8", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unaffected", product: "Teamcenter Visualization V14.0", vendor: "Siemens ", versions: [ { lessThan: "14.0.0.4", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unaffected", product: "Teamcenter Visualization V14.1", vendor: "Siemens ", versions: [ { lessThan: "14.1.0.5", status: "affected", version: "0", versionType: "custom", }, ], }, ], credits: [ { lang: "en", type: "finder", user: "00000000-0000-4000-9000-000000000000", value: "Michael Heinz and Nafiez reported these vulnerabilities to Siemens. ", }, ], descriptions: [ { lang: "en", supportingMedia: [ { base64: false, type: "text/html", value: "\nThe APDFL.dll contains a stack-based buffer overflow vulnerability that \ncould be triggered while parsing specially crafted PDF files. This could\n allow an attacker to execute code in the context of the current \nprocess.\n\n", }, ], value: "The APDFL.dll contains a stack-based buffer overflow vulnerability that \ncould be triggered while parsing specially crafted PDF files. This could\n allow an attacker to execute code in the context of the current \nprocess.\n\n", }, ], metrics: [ { cvssV3_1: { attackComplexity: "LOW", attackVector: "LOCAL", availabilityImpact: "HIGH", baseScore: 7.8, baseSeverity: "HIGH", confidentialityImpact: "HIGH", integrityImpact: "HIGH", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "REQUIRED", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", version: "3.1", }, format: "CVSS", scenarios: [ { lang: "en", value: "GENERAL", }, ], }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-121", description: "CWE-121 ", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2023-01-13T00:15:15.775Z", orgId: "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", shortName: "icscert", }, references: [ { url: "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15", }, { url: "https://cert-portal.siemens.com/productcert/html/ssa-360681.html", }, { url: "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json", }, ], solutions: [ { lang: "en", supportingMedia: [ { base64: false, type: "text/html", value: "\nSiemens released updates for the affected products and recommends updating to the latest versions:<br><ul><li><span style=\"background-color: var(--wht);\">JT2Go: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\">Update to V14.1.0.5 or later version</a><span style=\"background-color: var(--wht);\">. <br></span></li><li><span style=\"background-color: var(--wht);\">Teamcenter Visualization V13.3: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V13.3.0.8 or later version</a><span style=\"background-color: var(--wht);\">.<br></span></li><li><span style=\"background-color: var(--wht);\">Teamcenter Visualization V14.0: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V14.0.0.4 or later version</a><span style=\"background-color: var(--wht);\">.<br></span></li><li><span style=\"background-color: var(--wht);\">Teamcenter Visualization V14.1: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V14.1.0.5 or later version</a><span style=\"background-color: var(--wht);\">.</span></li></ul>", }, ], value: "Siemens released updates for the affected products and recommends updating to the latest versions:\n * JT2Go: Update to V14.1.0.5 or later version https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html . \n\n * Teamcenter Visualization V13.3: Update to V13.3.0.8 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.0: Update to V14.0.0.4 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.1: Update to V14.1.0.5 or later version https://support.sw.siemens.com/ .\n\n\n", }, ], source: { discovery: "EXTERNAL", }, workarounds: [ { lang: "en", supportingMedia: [ { base64: false, type: "text/html", value: "\n<p>Siemens identified the following specific workaround and mitigation user can apply to reduce risk: </p>\n\n<ul><li>Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.</li>\n</ul><p>As a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens' <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\">operational guidelines for industrial security</a></p> and following the recommendations in the product manuals. Siemens also provides <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\">additional information on industrial security</a>.<br>\nFor further inquiries on security vulnerabilities in Siemens products, users should contact <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\">Siemens</a>. <br>\nFor more information, see the associated Siemens security advisory SSA-360681 in <a target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\">HTML </a>and <a target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\">CSAF</a>.\n\n<br>", }, ], value: "Siemens identified the following specific workaround and mitigation user can apply to reduce risk: \n\n\n\n * Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.\n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens' operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security \n\n and following the recommendations in the product manuals. Siemens also provides additional information on industrial security https://www.siemens.com/industrialsecurity .\n\nFor further inquiries on security vulnerabilities in Siemens products, users should contact Siemens https://www.siemens.com/cert/advisories . \n\nFor more information, see the associated Siemens security advisory SSA-360681 in HTML https://cert-portal.siemens.com/productcert/html/ssa-360681.html and CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json .\n\n\n", }, ], x_generator: { engine: "Vulnogram 0.1.0-dev", }, }, }, cveMetadata: { assignerOrgId: "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", assignerShortName: "icscert", cveId: "CVE-2022-3159", datePublished: "2023-01-13T00:15:15.775Z", dateReserved: "2022-09-07T23:36:59.702Z", dateUpdated: "2025-01-16T22:01:53.147Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { fkie_nvd: { configurations: "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"14.1.0.5\", \"matchCriteriaId\": \"FA901DB7-5FBF-4146-BF63-39182FDF25D0\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"13.3.0\", \"versionEndExcluding\": \"13.3.0.8\", \"matchCriteriaId\": \"DF82E5C7-68B6-456B-9658-CCF1FB1DC4D9\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"14.0.0\", \"versionEndExcluding\": \"14.0.0.4\", \"matchCriteriaId\": \"E9BEAABD-3B22-4C8C-8BCA-50A04CC36547\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"14.1\", \"versionEndExcluding\": \"14.1.0.5\", \"matchCriteriaId\": \"DF975D6A-3832-4F88-BE9C-453354560C6C\"}]}]}]", descriptions: "[{\"lang\": \"en\", \"value\": \"The APDFL.dll contains a stack-based buffer overflow vulnerability that \\ncould be triggered while parsing specially crafted PDF files. This could\\n allow an attacker to execute code in the context of the current \\nprocess.\\n\\n\"}, {\"lang\": \"es\", \"value\": \"APDFL.dll contiene una vulnerabilidad de desbordamiento de b\\u00fafer en la regi\\u00f3n stack de la memoria que podr\\u00eda activarse al analizar archivos PDF especialmente manipulados. Esto podr\\u00eda permitir a un atacante ejecutar c\\u00f3digo en el contexto del proceso actual.\"}]", id: "CVE-2022-3159", lastModified: "2024-11-21T07:18:57.053", metrics: "{\"cvssMetricV31\": [{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}]}", published: "2023-01-13T01:15:09.600", references: "[{\"url\": \"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Patch\", \"Third Party Advisory\"]}, {\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Third Party Advisory\"]}, {\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]", sourceIdentifier: "ics-cert@hq.dhs.gov", vulnStatus: "Modified", weaknesses: "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-121\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]", }, nvd: "{\"cve\":{\"id\":\"CVE-2022-3159\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2023-01-13T01:15:09.600\",\"lastModified\":\"2024-11-21T07:18:57.053\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The APDFL.dll contains a stack-based buffer overflow vulnerability that \\ncould be triggered while parsing specially crafted PDF files. This could\\n allow an attacker to execute code in the context of the current \\nprocess.\\n\\n\"},{\"lang\":\"es\",\"value\":\"APDFL.dll contiene una vulnerabilidad de desbordamiento de búfer en la región stack de la memoria que podría activarse al analizar archivos PDF especialmente manipulados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"14.1.0.5\",\"matchCriteriaId\":\"FA901DB7-5FBF-4146-BF63-39182FDF25D0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.3.0\",\"versionEndExcluding\":\"13.3.0.8\",\"matchCriteriaId\":\"DF82E5C7-68B6-456B-9658-CCF1FB1DC4D9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.0.0\",\"versionEndExcluding\":\"14.0.0.4\",\"matchCriteriaId\":\"E9BEAABD-3B22-4C8C-8BCA-50A04CC36547\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.1\",\"versionEndExcluding\":\"14.1.0.5\",\"matchCriteriaId\":\"DF975D6A-3832-4F88-BE9C-453354560C6C\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}", vulnrichment: { containers: "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T01:00:10.535Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-3159\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-16T20:32:35.727245Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-16T20:32:38.114Z\"}}], \"cna\": {\"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Michael Heinz and Nafiez reported these vulnerabilities to Siemens.\\u00a0\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Siemens\\u00a0\", \"product\": \"JT2Go\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"14.1.0.5\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Siemens\\u00a0\", \"product\": \"Teamcenter Visualization V13.3\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"13.3.0.8\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Siemens\\u00a0\", \"product\": \"Teamcenter Visualization V14.0\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"14.0.0.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Siemens\\u00a0\", \"product\": \"Teamcenter Visualization V14.1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"14.1.0.5\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Siemens released updates for the affected products and recommends updating to the latest versions:\\n * JT2Go: Update to V14.1.0.5 or later version https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html .\\u00a0\\n\\n * Teamcenter Visualization V13.3: Update to V13.3.0.8 or later version https://support.sw.siemens.com/ .\\n\\n * Teamcenter Visualization V14.0: Update to V14.0.0.4 or later version https://support.sw.siemens.com/ .\\n\\n * Teamcenter Visualization V14.1: Update to V14.1.0.5 or later version https://support.sw.siemens.com/ .\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\nSiemens released updates for the affected products and recommends updating to the latest versions:<br><ul><li><span style=\\\"background-color: var(--wht);\\\">JT2Go: </span><a target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\\\">Update to V14.1.0.5 or later version</a><span style=\\\"background-color: var(--wht);\\\">. <br></span></li><li><span style=\\\"background-color: var(--wht);\\\">Teamcenter Visualization V13.3: </span><a target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://support.sw.siemens.com/\\\">Update to V13.3.0.8 or later version</a><span style=\\\"background-color: var(--wht);\\\">.<br></span></li><li><span style=\\\"background-color: var(--wht);\\\">Teamcenter Visualization V14.0: </span><a target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://support.sw.siemens.com/\\\">Update to V14.0.0.4 or later version</a><span style=\\\"background-color: var(--wht);\\\">.<br></span></li><li><span style=\\\"background-color: var(--wht);\\\">Teamcenter Visualization V14.1: </span><a target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://support.sw.siemens.com/\\\">Update to V14.1.0.5 or later version</a><span style=\\\"background-color: var(--wht);\\\">.</span></li></ul>\", \"base64\": false}]}], \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\"}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"Siemens identified the following specific workaround and mitigation user can apply to reduce risk: \\n\\n\\n\\n * Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.\\n\\n\\n\\nAs a general security measure, Siemens recommends protecting \\nnetwork access to devices with appropriate mechanisms. To operate the \\ndevices in a protected IT environment, Siemens recommends configuring \\nthe environment according to Siemens' operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security \\n\\n and following the recommendations in the product manuals. Siemens also provides additional information on industrial security https://www.siemens.com/industrialsecurity .\\n\\nFor further inquiries on security vulnerabilities in Siemens products, users should contact Siemens https://www.siemens.com/cert/advisories . \\n\\nFor more information, see the associated Siemens security advisory SSA-360681 in HTML https://cert-portal.siemens.com/productcert/html/ssa-360681.html and CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json .\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n<p>Siemens identified the following specific workaround and mitigation user can apply to reduce risk: </p>\\n\\n<ul><li>Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.</li>\\n</ul><p>As a general security measure, Siemens recommends protecting \\nnetwork access to devices with appropriate mechanisms. To operate the \\ndevices in a protected IT environment, Siemens recommends configuring \\nthe environment according to Siemens' <a target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.siemens.com/cert/operational-guidelines-industrial-security\\\">operational guidelines for industrial security</a></p> and following the recommendations in the product manuals. Siemens also provides <a target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.siemens.com/industrialsecurity\\\">additional information on industrial security</a>.<br>\\nFor further inquiries on security vulnerabilities in Siemens products, users should contact <a target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.siemens.com/cert/advisories\\\">Siemens</a>. <br>\\nFor more information, see the associated Siemens security advisory SSA-360681 in <a target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\\\">HTML </a>and <a target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\\\">CSAF</a>.\\n\\n<br>\", \"base64\": false}]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The APDFL.dll contains a stack-based buffer overflow vulnerability that \\ncould be triggered while parsing specially crafted PDF files. This could\\n allow an attacker to execute code in the context of the current \\nprocess.\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\nThe APDFL.dll contains a stack-based buffer overflow vulnerability that \\ncould be triggered while parsing specially crafted PDF files. This could\\n allow an attacker to execute code in the context of the current \\nprocess.\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"CWE-121 \"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2023-01-13T00:15:15.775Z\"}}}", cveMetadata: "{\"cveId\": \"CVE-2022-3159\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-01-16T22:01:53.147Z\", \"dateReserved\": \"2022-09-07T23:36:59.702Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2023-01-13T00:15:15.775Z\", \"assignerShortName\": \"icscert\"}", dataType: "CVE_RECORD", dataVersion: "5.1", }, }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.