The APDFL.dll contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-3159", "id": "GSD-2022-3159" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-3159" ], "details": "The APDFL.dll contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.", "id": "GSD-2022-3159", "modified": "2023-12-13T01:19:40.292942Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-3159", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "JT2Go", "version": { "version_data": [ { "version_affected": "=", "version_value": "0" } ] } }, { "product_name": "Teamcenter Visualization V13.3", "version": { "version_data": [ { "version_affected": "=", "version_value": "0" } ] } }, { "product_name": "Teamcenter Visualization V14.0", "version": { "version_data": [ { "version_affected": "=", "version_value": "0" } ] } }, { "product_name": "Teamcenter Visualization V14.1", "version": { "version_data": [ { "version_affected": "=", "version_value": "0" } ] } } ] }, "vendor_name": "Siemens\u00a0" } ] } }, "credits": [ { "lang": "en", "value": "Michael Heinz and Nafiez reported these vulnerabilities to Siemens.\u00a0" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The APDFL.dll contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process." } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-121", "lang": "eng", "value": "CWE-121 " } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15" }, { "name": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html" }, { "name": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json" } ] }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\nSiemens released updates for the affected products and recommends updating to the latest versions:\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eJT2Go: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u0026nbsp;\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V13.3: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V13.3.0.8 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.0: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.0.0.4 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.1: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003c/span\u003e\u003c/li\u003e\u003c/ul\u003e" } ], "value": "Siemens released updates for the affected products and recommends updating to the latest versions:\n * JT2Go: Update to V14.1.0.5 or later version https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html .\u00a0\n\n * Teamcenter Visualization V13.3: Update to V13.3.0.8 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.0: Update to V14.0.0.4 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.1: Update to V14.1.0.5 or later version https://support.sw.siemens.com/ .\n\n\n" } ], "source": { "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\u003cp\u003eSiemens identified the following specific workaround and mitigation user can apply to reduce risk: \u003c/p\u003e\n\n\u003cul\u003e\u003cli\u003eDo not open untrusted PDF files in JT2Go and Teamcenter Visualization.\u003c/li\u003e\n\u003c/ul\u003e\u003cp\u003eAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\"\u003eoperational guidelines for industrial security\u003c/a\u003e\u003c/p\u003e and following the recommendations in the product manuals. Siemens also provides \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eadditional information on industrial security\u003c/a\u003e.\u003cbr\u003e\nFor further inquiries on security vulnerabilities in Siemens products, users should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\"\u003eSiemens\u003c/a\u003e. \u003cbr\u003e\nFor more information, see the associated Siemens security advisory SSA-360681 in \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\"\u003eHTML \u003c/a\u003eand \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\"\u003eCSAF\u003c/a\u003e.\n\n\u003cbr\u003e" } ], "value": "Siemens identified the following specific workaround and mitigation user can apply to reduce risk: \n\n\n\n * Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.\n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security \n\n and following the recommendations in the product manuals. Siemens also provides additional information on industrial security https://www.siemens.com/industrialsecurity .\n\nFor further inquiries on security vulnerabilities in Siemens products, users should contact Siemens https://www.siemens.com/cert/advisories . \n\nFor more information, see the associated Siemens security advisory SSA-360681 in HTML https://cert-portal.siemens.com/productcert/html/ssa-360681.html and CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json .\n\n\n" } ] }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.3.0.8", "versionStartIncluding": "13.3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "14.1.0.5", "versionStartIncluding": "14.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "14.0.0.4", "versionStartIncluding": "14.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "14.1.0.5", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-3159" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "The APDFL.dll contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-787" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15", "refsource": "MISC", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15" }, { "name": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html", "refsource": "MISC", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html" }, { "name": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json", "refsource": "MISC", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } }, "lastModifiedDate": "2023-01-23T18:33Z", "publishedDate": "2023-01-13T01:15Z" } } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.