Type a vendor name or a vulnerability id.



All the vulnerabilites related to Siemens - Teamcenter Visualization V14.3
cve-2023-38070
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-08-02 17:30
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20818)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:30:14.028Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1.0.11"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.2.0.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2201",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2201.0010"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2302",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2302.0004"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20818)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-14T11:03:21.001Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38070",
    "datePublished": "2023-09-12T09:32:13.603Z",
    "dateReserved": "2023-07-12T13:18:53.822Z",
    "dateUpdated": "2024-08-02T17:30:14.028Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38527
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-08-13 07:50
Summary
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:46:55.719Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V34.1.258",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.0.254",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V2312",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0004",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:50:33.956Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38527",
    "datePublished": "2023-08-08T09:20:36.244Z",
    "dateReserved": "2023-07-19T09:55:44.210Z",
    "dateUpdated": "2024-08-13T07:50:33.956Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38532
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-08-13 07:50
Summary
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:46:55.753Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V34.1.258",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.0.254",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.1.171",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.1.0.11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.171), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.3). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:50:40.643Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38532",
    "datePublished": "2023-08-08T09:20:41.916Z",
    "dateReserved": "2023-07-19T09:55:44.211Z",
    "dateUpdated": "2024-08-13T07:50:40.643Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38074
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-08-02 17:30
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20840)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:30:14.057Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1.0.11"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.2.0.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2201",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2201.0010"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2302",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2302.0004"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20840)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-14T11:03:26.239Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38074",
    "datePublished": "2023-09-12T09:32:17.948Z",
    "dateReserved": "2023-07-12T13:18:53.822Z",
    "dateUpdated": "2024-08-02T17:30:14.057Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38073
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-08-02 17:30
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20826)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:30:14.105Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1.0.11"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.2.0.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2201",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2201.0010"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2302",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2302.0004"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20826)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-14T11:03:24.893Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38073",
    "datePublished": "2023-09-12T09:32:16.855Z",
    "dateReserved": "2023-07-12T13:18:53.822Z",
    "dateUpdated": "2024-08-02T17:30:14.105Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38528
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-08-13 07:50
Summary
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.197), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T file. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:46:56.390Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V34.1.258",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.0.254",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.1.197",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.1.184",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.1.0.11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.197), Parasolid V35.1 (All versions \u003c V35.1.184), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T file. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:50:35.245Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38528",
    "datePublished": "2023-08-08T09:20:37.393Z",
    "dateReserved": "2023-07-19T09:55:44.210Z",
    "dateUpdated": "2024-08-13T07:50:35.245Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-26276
Vulnerability from cvelistv5
Published
2024-04-09 08:34
Modified
2024-08-13 07:54
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "parasolid",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "35.1.254",
                "status": "affected",
                "version": "35.1",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "parasolid",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "36.0.207",
                "status": "affected",
                "version": "36.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "parasolid",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "36.1.147",
                "status": "affected",
                "version": "36.1",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-26276",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T13:40:25.505191Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-06T14:53:58.636Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:07:18.871Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0004",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.1.254",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V36.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V36.0.207",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V36.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V36.1.147",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V2312",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0004",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:54:02.376Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-26276",
    "datePublished": "2024-04-09T08:34:37.744Z",
    "dateReserved": "2024-02-15T10:54:03.168Z",
    "dateUpdated": "2024-08-13T07:54:02.376Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38075
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-08-02 17:30
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20842)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:30:13.592Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1.0.11"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.2.0.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2201",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2201.0010"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2302",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2302.0004"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20842)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "CWE-416: Use After Free",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-14T11:03:27.558Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38075",
    "datePublished": "2023-09-12T09:32:19.039Z",
    "dateReserved": "2023-07-12T13:18:53.823Z",
    "dateUpdated": "2024-08-02T17:30:13.592Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-32637
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-13 07:54
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:ps_iges_parasolid_translator_component:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ps_iges_parasolid_translator_component",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v27.1.215 ",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-32637",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T13:37:33.414539Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-18T18:07:35.849Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:13:40.086Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0005",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V2312",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0005",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "CWE-476: NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:54:07.678Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-32637",
    "datePublished": "2024-05-14T10:02:44.682Z",
    "dateReserved": "2024-04-16T10:52:15.707Z",
    "dateUpdated": "2024-08-13T07:54:07.678Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-51439
Vulnerability from cvelistv5
Published
2024-01-09 10:00
Modified
2024-08-02 22:32
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:32:10.018Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.13"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1.0.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.2.0.9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.6), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.13), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.12), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.9), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.6). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-09T10:00:14.394Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-51439",
    "datePublished": "2024-01-09T10:00:14.394Z",
    "dateReserved": "2023-12-19T11:47:14.991Z",
    "dateUpdated": "2024-08-02T22:32:10.018Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-51744
Vulnerability from cvelistv5
Published
2024-01-09 10:00
Modified
2024-08-02 22:40
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:40:34.169Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.13"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1.0.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.2.0.9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.6), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.13), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.12), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.9), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.6). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "CWE-476: NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-09T10:00:15.708Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-51744",
    "datePublished": "2024-01-09T10:00:15.708Z",
    "dateReserved": "2023-12-22T11:30:22.671Z",
    "dateUpdated": "2024-08-02T22:40:34.169Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-26275
Vulnerability from cvelistv5
Published
2024-04-09 08:34
Modified
2024-08-13 07:54
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "jt2go",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2312.0004",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "parasolid",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "35.1.254",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "36.0.207",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "36.1.147",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*",
              "cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*",
              "cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "teamcenter_visualization",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "14.2",
                "versionType": "custom"
              },
              {
                "lessThan": "14.3.0.9",
                "status": "affected",
                "version": "14.3",
                "versionType": "custom"
              },
              {
                "lessThan": "2312.0004",
                "status": "affected",
                "version": "2312",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-26275",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-09T15:24:40.222186Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-31T18:33:02.344Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:07:19.343Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0004",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.1.254",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V36.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V36.0.207",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V36.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V36.1.147",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V2312",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0004",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:54:00.911Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-26275",
    "datePublished": "2024-04-09T08:34:36.604Z",
    "dateReserved": "2024-02-15T10:54:03.168Z",
    "dateUpdated": "2024-08-13T07:54:00.911Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-32635
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-13 07:54
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "parasolid",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "35.1.256",
                "status": "affected",
                "version": "35.1",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "parasolid",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "36.0.208",
                "status": "affected",
                "version": "36.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "parasolid",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "36.1.173",
                "status": "affected",
                "version": "36.1",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-32635",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T13:37:49.970409Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-06T17:27:51.096Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:13:40.417Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0005",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V2312",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0005",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:54:05.071Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-32635",
    "datePublished": "2024-05-14T10:02:42.291Z",
    "dateReserved": "2024-04-16T10:52:15.707Z",
    "dateUpdated": "2024-08-13T07:54:05.071Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-51746
Vulnerability from cvelistv5
Published
2024-01-09 10:00
Modified
2024-09-04 15:14
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:48:11.101Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-51746",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-04T15:13:57.367529Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-04T15:14:05.889Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.13"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1.0.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.2.0.9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.6), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.13), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.12), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.9), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-09T10:00:18.333Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-51746",
    "datePublished": "2024-01-09T10:00:18.333Z",
    "dateReserved": "2023-12-22T11:30:22.672Z",
    "dateUpdated": "2024-09-04T15:14:05.889Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38530
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-08-13 07:50
Summary
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:46:55.952Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V34.1.258",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.0.254",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.1.171",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.1.0.11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.171), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:50:37.879Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38530",
    "datePublished": "2023-08-08T09:20:39.660Z",
    "dateReserved": "2023-07-19T09:55:44.210Z",
    "dateUpdated": "2024-08-13T07:50:37.879Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38524
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-08-13 07:50
Summary
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain null pointer dereference while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:46:55.704Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V34.1.258",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.0.254",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.1.171",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.1.0.11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.171), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.3). The affected applications contain null pointer dereference while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 2,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "CWE-476: NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:50:30.129Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38524",
    "datePublished": "2023-08-08T09:20:32.849Z",
    "dateReserved": "2023-07-19T09:55:44.209Z",
    "dateUpdated": "2024-08-13T07:50:30.129Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38531
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-08-13 07:50
Summary
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:46:55.885Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V34.1.258",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.0.254",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.1.184",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V2312",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0004",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:50:39.222Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38531",
    "datePublished": "2023-08-08T09:20:40.773Z",
    "dateReserved": "2023-07-19T09:55:44.210Z",
    "dateUpdated": "2024-08-13T07:50:39.222Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38526
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-08-13 07:50
Summary
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:46:56.282Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V34.1.258",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.0.254",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.1.171",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.1.0.11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.171), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:50:32.703Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38526",
    "datePublished": "2023-08-08T09:20:35.106Z",
    "dateReserved": "2023-07-19T09:55:44.210Z",
    "dateUpdated": "2024-08-13T07:50:32.703Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-34085
Vulnerability from cvelistv5
Published
2024-05-14 10:03
Modified
2024-08-02 02:42
Severity
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "teamcenter_visualization",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "14.1.0.13",
                "status": "affected",
                "version": "14.1",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "teamcenter_visualization",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "14.2.0.10",
                "status": "affected",
                "version": "14.2",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "jt2go",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2312.0001",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "teamcenter_visualization",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2312.0001",
                "status": "affected",
                "version": "2312",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-34085",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T14:07:42.511828Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-06T18:03:43.492Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:42:59.891Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0001",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.1.0.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V2312",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0001",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0001), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.13), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.10), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.7), Teamcenter Visualization V2312 (All versions \u003c V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:24:54.668Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-34085",
    "datePublished": "2024-05-14T10:03:09.574Z",
    "dateReserved": "2024-04-30T09:05:07.900Z",
    "dateUpdated": "2024-08-02T02:42:59.891Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38072
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-08-02 17:30
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20825)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:30:13.939Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1.0.11"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.2.0.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2201",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2201.0010"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2302",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2302.0004"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20825)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-14T11:03:23.586Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38072",
    "datePublished": "2023-09-12T09:32:15.739Z",
    "dateReserved": "2023-07-12T13:18:53.822Z",
    "dateUpdated": "2024-08-02T17:30:13.939Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-34086
Vulnerability from cvelistv5
Published
2024-05-14 10:03
Modified
2024-08-02 02:42
Severity
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "jt2go",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "V2312.0001",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "teamcenter_visualization",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "V14.1.0.13",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "teamcenter_visualization",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "14.2.0.10",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "teamcenter_visualization",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "V2312.0001",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "teamcenter_visualization",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "14.3.0.7",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-34086",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T15:19:05.198442Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-06T18:22:25.821Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:42:59.863Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0001",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.1.0.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V2312",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0001",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0001), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.13), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.10), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.7), Teamcenter Visualization V2312 (All versions \u003c V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file.\r\nThis could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:24:55.854Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-34086",
    "datePublished": "2024-05-14T10:03:10.774Z",
    "dateReserved": "2024-04-30T09:05:07.900Z",
    "dateUpdated": "2024-08-02T02:42:59.863Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-32636
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-13 07:54
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "parasolid",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "35.1.256",
                "status": "affected",
                "version": "35.1",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "parasolid",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "36.0.208",
                "status": "affected",
                "version": "36.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "parasolid",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "36.1.173",
                "status": "affected",
                "version": "36.1",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-32636",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T13:37:41.622204Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-06T17:29:19.950Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:13:40.376Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0005",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V2312",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0005",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:54:06.352Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-32636",
    "datePublished": "2024-05-14T10:02:43.480Z",
    "dateReserved": "2024-04-16T10:52:15.707Z",
    "dateUpdated": "2024-08-13T07:54:06.352Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-51745
Vulnerability from cvelistv5
Published
2024-01-09 10:00
Modified
2024-08-02 22:40
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:40:34.255Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.13"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1.0.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.2.0.9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.6), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.13), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.12), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.9), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-09T10:00:17.032Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-51745",
    "datePublished": "2024-01-09T10:00:17.032Z",
    "dateReserved": "2023-12-22T11:30:22.671Z",
    "dateUpdated": "2024-08-02T22:40:34.255Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38529
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-08-13 07:50
Summary
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:46:56.218Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V34.1.258",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.0.254",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.1.184",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V2312",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0004",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:50:36.555Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38529",
    "datePublished": "2023-08-08T09:20:38.540Z",
    "dateReserved": "2023-07-19T09:55:44.210Z",
    "dateUpdated": "2024-08-13T07:50:36.555Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38525
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-08-13 07:50
Summary
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:46:56.430Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V34.1.258",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.0.254",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.1.171",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.1.0.11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.171), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:50:31.439Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38525",
    "datePublished": "2023-08-08T09:20:33.970Z",
    "dateReserved": "2023-07-19T09:55:44.210Z",
    "dateUpdated": "2024-08-13T07:50:31.439Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-26277
Vulnerability from cvelistv5
Published
2024-04-09 08:34
Modified
2024-08-13 07:54
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-26277",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-09T19:51:56.120704Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:49:18.998Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:07:18.954Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0004",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.1.254",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V36.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V36.0.207",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V36.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V36.1.147",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V2312",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0004",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "CWE-476: NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:54:03.735Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-26277",
    "datePublished": "2024-04-09T08:34:38.896Z",
    "dateReserved": "2024-02-15T10:54:03.168Z",
    "dateUpdated": "2024-08-13T07:54:03.735Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38071
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-08-02 17:30
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20824)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:30:13.596Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1.0.11"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.2.0.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2201",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2201.0010"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2302",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2302.0004"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20824)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-14T11:03:22.297Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38071",
    "datePublished": "2023-09-12T09:32:14.673Z",
    "dateReserved": "2023-07-12T13:18:53.822Z",
    "dateUpdated": "2024-08-02T17:30:13.596Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-38076
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-08-02 17:30
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21041)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:30:13.747Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1.0.11"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.2.0.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2201",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2201.0010"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2302",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2302.0004"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21041)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-14T11:03:28.851Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-38076",
    "datePublished": "2023-09-12T09:32:20.160Z",
    "dateReserved": "2023-07-12T13:18:53.823Z",
    "dateUpdated": "2024-08-02T17:30:13.747Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}