Search criteria
78 vulnerabilities found for Tecnomatix Plant Simulation V2404 by Siemens
CVE-2025-32454 (GCVE-0-2025-32454)
Vulnerability from cvelistv5 – Published: 2025-05-13 09:38 – Updated: 2025-06-10 15:17
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), Teamcenter Visualization V2406 (All versions < V2406.0008), Teamcenter Visualization V2412 (All versions < V2412.0004), Tecnomatix Plant Simulation V2404 (All versions < V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.14
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-32454",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-13T14:10:31.587086Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-13T14:12:07.157Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0013",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.14), Teamcenter Visualization V2312 (All versions \u003c V2312.0010), Teamcenter Visualization V2406 (All versions \u003c V2406.0008), Teamcenter Visualization V2412 (All versions \u003c V2412.0004), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T15:17:24.833Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-542540.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-486186.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-32454",
"datePublished": "2025-05-13T09:38:44.621Z",
"dateReserved": "2025-04-08T15:46:35.199Z",
"dateUpdated": "2025-06-10T15:17:24.833Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-27438 (GCVE-0-2025-27438)
Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:26
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27438",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T13:26:38.797340Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:26:49.545Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:31.489Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-27438",
"datePublished": "2025-03-11T09:48:31.489Z",
"dateReserved": "2025-02-25T16:39:12.235Z",
"dateUpdated": "2025-03-11T13:26:49.545Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-25267 (GCVE-0-2025-25267)
Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:20
VLAI?
Summary
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application does not properly restrict the scope of files accessible to the simulation model. This could allow an unauthorized attacker to compromise the confidentiality of the system.
Severity ?
6.2 (Medium)
CWE
- CWE-552 - Files or Directories Accessible to External Parties
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Tecnomatix Plant Simulation V2302 |
Affected:
0 , < V2302.0021
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-25267",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T14:20:14.270383Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T14:20:34.812Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application does not properly restrict the scope of files accessible to the simulation model. This could allow an unauthorized attacker to compromise the confidentiality of the system."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552: Files or Directories Accessible to External Parties",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:20.909Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-507653.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-25267",
"datePublished": "2025-03-11T09:48:20.909Z",
"dateReserved": "2025-02-06T12:40:49.316Z",
"dateUpdated": "2025-03-11T14:20:34.812Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-25266 (GCVE-0-2025-25266)
Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:22
VLAI?
Summary
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application does not properly restrict access to the file deletion functionality.
This could allow an unauthorized attacker to delete files even when access to the system should be prohibited, resulting in potential data loss or unauthorized modification of system files.
Severity ?
CWE
- CWE-552 - Files or Directories Accessible to External Parties
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Tecnomatix Plant Simulation V2302 |
Affected:
0 , < V2302.0021
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-25266",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T14:21:49.617519Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T14:22:07.380Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application does not properly restrict access to the file deletion functionality.\r\nThis could allow an unauthorized attacker to delete files even when access to the system should be prohibited, resulting in potential data loss or unauthorized modification of system files."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552: Files or Directories Accessible to External Parties",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:19.594Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-507653.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-25266",
"datePublished": "2025-03-11T09:48:19.594Z",
"dateReserved": "2025-02-06T12:40:49.316Z",
"dateUpdated": "2025-03-11T14:22:07.380Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23402 (GCVE-0-2025-23402)
Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:29
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files.
An attacker could leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-416 - Use After Free
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23402",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T14:28:48.184791Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T14:29:22.710Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files.\r\nAn attacker could leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416: Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:18.241Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-23402",
"datePublished": "2025-03-11T09:48:18.241Z",
"dateReserved": "2025-01-15T14:20:46.047Z",
"dateUpdated": "2025-03-11T14:29:22.710Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23401 (GCVE-0-2025-23401)
Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:31
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23401",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T14:30:32.123564Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T14:31:03.615Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:16.806Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-23401",
"datePublished": "2025-03-11T09:48:16.806Z",
"dateReserved": "2025-01-15T14:20:46.047Z",
"dateUpdated": "2025-03-11T14:31:03.615Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23400 (GCVE-0-2025-23400)
Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:59
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23400",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T14:57:36.559116Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T14:59:33.908Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:15.383Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-23400",
"datePublished": "2025-03-11T09:48:15.383Z",
"dateReserved": "2025-01-15T14:20:46.047Z",
"dateUpdated": "2025-03-11T14:59:33.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23399 (GCVE-0-2025-23399)
Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 15:05
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23399",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T15:02:55.935480Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T15:05:09.830Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:13.954Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-23399",
"datePublished": "2025-03-11T09:48:13.954Z",
"dateReserved": "2025-01-15T14:20:46.047Z",
"dateUpdated": "2025-03-11T15:05:09.830Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23398 (GCVE-0-2025-23398)
Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:45
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23398",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T13:45:05.413293Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:45:43.215Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:12.525Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-23398",
"datePublished": "2025-03-11T09:48:12.525Z",
"dateReserved": "2025-01-15T14:20:46.047Z",
"dateUpdated": "2025-03-11T13:45:43.215Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23397 (GCVE-0-2025-23397)
Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:48
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23397",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T13:47:07.609257Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:48:23.588Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:11.135Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-23397",
"datePublished": "2025-03-11T09:48:11.135Z",
"dateReserved": "2025-01-15T14:20:46.046Z",
"dateUpdated": "2025-03-11T13:48:23.588Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23396 (GCVE-0-2025-23396)
Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:49
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.
This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23396",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T13:49:04.408654Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:49:18.776Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:09.716Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-23396",
"datePublished": "2025-03-11T09:48:09.716Z",
"dateReserved": "2025-01-15T14:20:46.046Z",
"dateUpdated": "2025-03-11T13:49:18.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-53242 (GCVE-0-2024-53242)
Vulnerability from cvelistv5 – Published: 2024-12-10 13:54 – Updated: 2024-12-10 17:17
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.14
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-53242",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-10T15:17:17.154033Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T17:17:29.175Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0016",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0016), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T13:54:13.403Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-53242",
"datePublished": "2024-12-10T13:54:13.403Z",
"dateReserved": "2024-11-19T17:51:57.294Z",
"dateUpdated": "2024-12-10T17:17:29.175Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-53041 (GCVE-0-2024-53041)
Vulnerability from cvelistv5 – Published: 2024-12-10 13:54 – Updated: 2024-12-10 17:17
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000)
Severity ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.14
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-53041",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-10T15:17:30.639993Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T17:17:19.652Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0016",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0016), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T13:54:12.113Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-53041",
"datePublished": "2024-12-10T13:54:12.113Z",
"dateReserved": "2024-11-19T16:38:17.725Z",
"dateUpdated": "2024-12-10T17:17:19.652Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-52574 (GCVE-0-2024-52574)
Vulnerability from cvelistv5 – Published: 2024-11-18 15:39 – Updated: 2024-12-10 13:54
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24543)
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.14
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tecnomatix_plant_simulation",
"vendor": "siemens",
"versions": [
{
"lessThan": "2302.0018",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2404.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tecnomatix_plant_simulation",
"vendor": "siemens",
"versions": [
{
"lessThan": "2302.0018",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2404.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-52574",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-18T17:58:40.018851Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-18T18:08:38.549Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0018",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24543)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T13:54:10.791Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-52574",
"datePublished": "2024-11-18T15:39:38.552Z",
"dateReserved": "2024-11-14T12:25:53.336Z",
"dateUpdated": "2024-12-10T13:54:10.791Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-52573 (GCVE-0-2024-52573)
Vulnerability from cvelistv5 – Published: 2024-11-18 15:39 – Updated: 2024-12-10 13:54
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24521)
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.14
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tecnomatix_plant_simulation",
"vendor": "siemens",
"versions": [
{
"lessThan": "2302.0018",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2404.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tecnomatix_plant_simulation",
"vendor": "siemens",
"versions": [
{
"lessThan": "2302.0018",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2404.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-52573",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-18T17:58:35.292347Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-18T18:08:38.439Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0018",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24521)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T13:54:09.478Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-52573",
"datePublished": "2024-11-18T15:39:37.042Z",
"dateReserved": "2024-11-14T12:25:53.336Z",
"dateUpdated": "2024-12-10T13:54:09.478Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-32454 (GCVE-0-2025-32454)
Vulnerability from nvd – Published: 2025-05-13 09:38 – Updated: 2025-06-10 15:17
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), Teamcenter Visualization V2406 (All versions < V2406.0008), Teamcenter Visualization V2412 (All versions < V2412.0004), Tecnomatix Plant Simulation V2404 (All versions < V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.14
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-32454",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-13T14:10:31.587086Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-13T14:12:07.157Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0013",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.14), Teamcenter Visualization V2312 (All versions \u003c V2312.0010), Teamcenter Visualization V2406 (All versions \u003c V2406.0008), Teamcenter Visualization V2412 (All versions \u003c V2412.0004), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T15:17:24.833Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-542540.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-486186.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-32454",
"datePublished": "2025-05-13T09:38:44.621Z",
"dateReserved": "2025-04-08T15:46:35.199Z",
"dateUpdated": "2025-06-10T15:17:24.833Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-27438 (GCVE-0-2025-27438)
Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:26
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27438",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T13:26:38.797340Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:26:49.545Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:31.489Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-27438",
"datePublished": "2025-03-11T09:48:31.489Z",
"dateReserved": "2025-02-25T16:39:12.235Z",
"dateUpdated": "2025-03-11T13:26:49.545Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-25267 (GCVE-0-2025-25267)
Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:20
VLAI?
Summary
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application does not properly restrict the scope of files accessible to the simulation model. This could allow an unauthorized attacker to compromise the confidentiality of the system.
Severity ?
6.2 (Medium)
CWE
- CWE-552 - Files or Directories Accessible to External Parties
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Tecnomatix Plant Simulation V2302 |
Affected:
0 , < V2302.0021
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-25267",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T14:20:14.270383Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T14:20:34.812Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application does not properly restrict the scope of files accessible to the simulation model. This could allow an unauthorized attacker to compromise the confidentiality of the system."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552: Files or Directories Accessible to External Parties",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:20.909Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-507653.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-25267",
"datePublished": "2025-03-11T09:48:20.909Z",
"dateReserved": "2025-02-06T12:40:49.316Z",
"dateUpdated": "2025-03-11T14:20:34.812Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-25266 (GCVE-0-2025-25266)
Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:22
VLAI?
Summary
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application does not properly restrict access to the file deletion functionality.
This could allow an unauthorized attacker to delete files even when access to the system should be prohibited, resulting in potential data loss or unauthorized modification of system files.
Severity ?
CWE
- CWE-552 - Files or Directories Accessible to External Parties
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Tecnomatix Plant Simulation V2302 |
Affected:
0 , < V2302.0021
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-25266",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T14:21:49.617519Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T14:22:07.380Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application does not properly restrict access to the file deletion functionality.\r\nThis could allow an unauthorized attacker to delete files even when access to the system should be prohibited, resulting in potential data loss or unauthorized modification of system files."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552: Files or Directories Accessible to External Parties",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:19.594Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-507653.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-25266",
"datePublished": "2025-03-11T09:48:19.594Z",
"dateReserved": "2025-02-06T12:40:49.316Z",
"dateUpdated": "2025-03-11T14:22:07.380Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23402 (GCVE-0-2025-23402)
Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:29
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files.
An attacker could leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-416 - Use After Free
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23402",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T14:28:48.184791Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T14:29:22.710Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files.\r\nAn attacker could leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416: Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:18.241Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-23402",
"datePublished": "2025-03-11T09:48:18.241Z",
"dateReserved": "2025-01-15T14:20:46.047Z",
"dateUpdated": "2025-03-11T14:29:22.710Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23401 (GCVE-0-2025-23401)
Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:31
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23401",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T14:30:32.123564Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T14:31:03.615Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:16.806Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-23401",
"datePublished": "2025-03-11T09:48:16.806Z",
"dateReserved": "2025-01-15T14:20:46.047Z",
"dateUpdated": "2025-03-11T14:31:03.615Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23400 (GCVE-0-2025-23400)
Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:59
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23400",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T14:57:36.559116Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T14:59:33.908Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:15.383Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-23400",
"datePublished": "2025-03-11T09:48:15.383Z",
"dateReserved": "2025-01-15T14:20:46.047Z",
"dateUpdated": "2025-03-11T14:59:33.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23399 (GCVE-0-2025-23399)
Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 15:05
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23399",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T15:02:55.935480Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T15:05:09.830Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:13.954Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-23399",
"datePublished": "2025-03-11T09:48:13.954Z",
"dateReserved": "2025-01-15T14:20:46.047Z",
"dateUpdated": "2025-03-11T15:05:09.830Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23398 (GCVE-0-2025-23398)
Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:45
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23398",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T13:45:05.413293Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:45:43.215Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:12.525Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-23398",
"datePublished": "2025-03-11T09:48:12.525Z",
"dateReserved": "2025-01-15T14:20:46.047Z",
"dateUpdated": "2025-03-11T13:45:43.215Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23397 (GCVE-0-2025-23397)
Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:48
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23397",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T13:47:07.609257Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:48:23.588Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:11.135Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-23397",
"datePublished": "2025-03-11T09:48:11.135Z",
"dateReserved": "2025-01-15T14:20:46.046Z",
"dateUpdated": "2025-03-11T13:48:23.588Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-23396 (GCVE-0-2025-23396)
Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:49
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.
This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.3 |
Affected:
0 , < V14.3.0.13
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23396",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-11T13:49:04.408654Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:49:18.776Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0021",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:48:09.716Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-23396",
"datePublished": "2025-03-11T09:48:09.716Z",
"dateReserved": "2025-01-15T14:20:46.046Z",
"dateUpdated": "2025-03-11T13:49:18.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-53242 (GCVE-0-2024-53242)
Vulnerability from nvd – Published: 2024-12-10 13:54 – Updated: 2024-12-10 17:17
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.14
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-53242",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-10T15:17:17.154033Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T17:17:29.175Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0016",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0016), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T13:54:13.403Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-53242",
"datePublished": "2024-12-10T13:54:13.403Z",
"dateReserved": "2024-11-19T17:51:57.294Z",
"dateUpdated": "2024-12-10T17:17:29.175Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-53041 (GCVE-0-2024-53041)
Vulnerability from nvd – Published: 2024-12-10 13:54 – Updated: 2024-12-10 17:17
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000)
Severity ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.14
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-53041",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-10T15:17:30.639993Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T17:17:19.652Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0016",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0016), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T13:54:12.113Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-53041",
"datePublished": "2024-12-10T13:54:12.113Z",
"dateReserved": "2024-11-19T16:38:17.725Z",
"dateUpdated": "2024-12-10T17:17:19.652Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-52574 (GCVE-0-2024-52574)
Vulnerability from nvd – Published: 2024-11-18 15:39 – Updated: 2024-12-10 13:54
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24543)
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.14
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tecnomatix_plant_simulation",
"vendor": "siemens",
"versions": [
{
"lessThan": "2302.0018",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2404.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tecnomatix_plant_simulation",
"vendor": "siemens",
"versions": [
{
"lessThan": "2302.0018",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2404.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-52574",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-18T17:58:40.018851Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-18T18:08:38.549Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0018",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24543)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T13:54:10.791Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-52574",
"datePublished": "2024-11-18T15:39:38.552Z",
"dateReserved": "2024-11-14T12:25:53.336Z",
"dateUpdated": "2024-12-10T13:54:10.791Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-52573 (GCVE-0-2024-52573)
Vulnerability from nvd – Published: 2024-11-18 15:39 – Updated: 2024-12-10 13:54
VLAI?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24521)
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.2 |
Affected:
0 , < V14.2.0.14
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tecnomatix_plant_simulation",
"vendor": "siemens",
"versions": [
{
"lessThan": "2302.0018",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2404.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tecnomatix_plant_simulation",
"vendor": "siemens",
"versions": [
{
"lessThan": "2302.0018",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2404.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-52573",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-18T17:58:35.292347Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-18T18:08:38.439Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2302.0018",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0007",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24521)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T13:54:09.478Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-52573",
"datePublished": "2024-11-18T15:39:37.042Z",
"dateReserved": "2024-11-14T12:25:53.336Z",
"dateUpdated": "2024-12-10T13:54:09.478Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}