Search criteria
24 vulnerabilities found for V-Server Lite by Fuji Electric
VAR-201809-0083
Vulnerability from variot - Updated: 2023-12-18 13:56A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior. Fuji Electric V-Server Lite Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a buffer. An attacker can leverage this vulnerability to execute arbitrary code in the context of the current process. Failed exploit attempts will likely cause a denial-of-service condition. V-Server Lite 4.0.3.0 and prior versions are vulnerable
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201809-0083",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "v-server",
"scope": "lte",
"trust": 1.0,
"vendor": "fujielectric",
"version": "4.0.3.0"
},
{
"model": "v-server",
"scope": "lte",
"trust": 0.8,
"vendor": "fuji electric",
"version": "lite 4.0.3.0"
},
{
"model": "v-server lite",
"scope": null,
"trust": 0.7,
"vendor": "fuji electric",
"version": null
},
{
"model": "v-server",
"scope": "eq",
"trust": 0.6,
"vendor": "fujielectric",
"version": "4.0.3.0"
},
{
"model": "electric v-server lite",
"scope": "eq",
"trust": 0.3,
"vendor": "fuji",
"version": "4.0.3.0"
},
{
"model": "electric v-server lite",
"scope": "eq",
"trust": 0.3,
"vendor": "fuji",
"version": "4.0.0.0"
},
{
"model": "electric v-server lite",
"scope": "eq",
"trust": 0.3,
"vendor": "fuji",
"version": "3.3.22.0"
},
{
"model": "electric v-server lite",
"scope": "eq",
"trust": 0.3,
"vendor": "fuji",
"version": "3.0.1.0"
},
{
"model": "electric v-server lite",
"scope": "eq",
"trust": 0.3,
"vendor": "fuji",
"version": "2.1.36.0"
},
{
"model": "electric v-server lite",
"scope": "eq",
"trust": 0.3,
"vendor": "fuji",
"version": "2.0.0.0"
},
{
"model": "electric v-server lite",
"scope": "ne",
"trust": 0.3,
"vendor": "fuji",
"version": "4.0.4.0"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-18-1023"
},
{
"db": "BID",
"id": "105328"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010848"
},
{
"db": "NVD",
"id": "CVE-2018-10637"
},
{
"db": "CNNVD",
"id": "CNNVD-201809-575"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.0.3.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-10637"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ariele Caltabiano (kimiya)",
"sources": [
{
"db": "ZDI",
"id": "ZDI-18-1023"
}
],
"trust": 0.7
},
"cve": "CVE-2018-10637",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.8,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2018-10637",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "ZDI",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "CVE-2018-10637",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "HIGH",
"trust": 0.7,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-10637",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-10637",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "ZDI",
"id": "CVE-2018-10637",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201809-575",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-18-1023"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010848"
},
{
"db": "NVD",
"id": "CVE-2018-10637"
},
{
"db": "CNNVD",
"id": "CNNVD-201809-575"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior. Fuji Electric V-Server Lite Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a buffer. An attacker can leverage this vulnerability to execute arbitrary code in the context of the current process. Failed exploit attempts will likely cause a denial-of-service condition. \nV-Server Lite 4.0.3.0 and prior versions are vulnerable",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-10637"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010848"
},
{
"db": "ZDI",
"id": "ZDI-18-1023"
},
{
"db": "BID",
"id": "105328"
}
],
"trust": 2.52
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-10637",
"trust": 3.4
},
{
"db": "ICS CERT",
"id": "ICSA-18-254-02",
"trust": 2.7
},
{
"db": "BID",
"id": "105328",
"trust": 1.9
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010848",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-6376",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-18-1023",
"trust": 0.7
},
{
"db": "CNNVD",
"id": "CNNVD-201809-575",
"trust": 0.6
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-18-1023"
},
{
"db": "BID",
"id": "105328"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010848"
},
{
"db": "NVD",
"id": "CVE-2018-10637"
},
{
"db": "CNNVD",
"id": "CNNVD-201809-575"
}
]
},
"id": "VAR-201809-0083",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.87058824
},
"last_update_date": "2023-12-18T13:56:56.234000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.fujielectric.co.jp/"
},
{
"title": "Fuji Electric has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-18-254-02"
},
{
"title": "Fuji Electric V-Server Lite Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=84842"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-18-1023"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010848"
},
{
"db": "CNNVD",
"id": "CNNVD-201809-575"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-010848"
},
{
"db": "NVD",
"id": "CVE-2018-10637"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.4,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-18-254-02"
},
{
"trust": 1.6,
"url": "http://www.securityfocus.com/bid/105328"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-10637"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-10637"
},
{
"trust": 0.3,
"url": "http://www.fujielectric.com/"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-18-1023"
},
{
"db": "BID",
"id": "105328"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010848"
},
{
"db": "NVD",
"id": "CVE-2018-10637"
},
{
"db": "CNNVD",
"id": "CNNVD-201809-575"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-18-1023"
},
{
"db": "BID",
"id": "105328"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010848"
},
{
"db": "NVD",
"id": "CVE-2018-10637"
},
{
"db": "CNNVD",
"id": "CNNVD-201809-575"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-09-12T00:00:00",
"db": "ZDI",
"id": "ZDI-18-1023"
},
{
"date": "2018-09-11T00:00:00",
"db": "BID",
"id": "105328"
},
{
"date": "2018-12-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-010848"
},
{
"date": "2018-09-13T19:29:00.277000",
"db": "NVD",
"id": "CVE-2018-10637"
},
{
"date": "2018-09-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201809-575"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-09-12T00:00:00",
"db": "ZDI",
"id": "ZDI-18-1023"
},
{
"date": "2018-09-11T00:00:00",
"db": "BID",
"id": "105328"
},
{
"date": "2018-12-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-010848"
},
{
"date": "2019-10-09T23:32:58.743000",
"db": "NVD",
"id": "CVE-2018-10637"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201809-575"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201809-575"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Fuji Electric V-Server Lite Buffer error vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-010848"
},
{
"db": "CNNVD",
"id": "CNNVD-201809-575"
}
],
"trust": 1.4
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201809-575"
}
],
"trust": 0.6
}
}
VAR-202101-1105
Vulnerability from variot - Updated: 2023-12-18 11:48A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202101-1105",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "v-simulator",
"scope": "lt",
"trust": 1.0,
"vendor": "fujielectric",
"version": "4.0.10.0"
},
{
"model": "v-server",
"scope": "lt",
"trust": 1.0,
"vendor": "fujielectric",
"version": "4.0.10.0"
},
{
"model": "v-simulator",
"scope": "eq",
"trust": 0.8,
"vendor": "\u5bcc\u58eb\u96fb\u6a5f",
"version": "lite 4.0.10.0"
},
{
"model": "v-server",
"scope": null,
"trust": 0.8,
"vendor": "\u5bcc\u58eb\u96fb\u6a5f",
"version": null
},
{
"model": "v-server lite",
"scope": null,
"trust": 0.7,
"vendor": "fuji electric",
"version": null
},
{
"model": "electric tellus lite v-simulator",
"scope": "lt",
"trust": 0.6,
"vendor": "fuji",
"version": "4.0.10.0"
},
{
"model": "electric v-server lite",
"scope": "lt",
"trust": 0.6,
"vendor": "fuji",
"version": "4.0.10.0"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-099"
},
{
"db": "CNVD",
"id": "CNVD-2021-17707"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002821"
},
{
"db": "NVD",
"id": "CVE-2021-22641"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0.10.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0.10.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22641"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "khangkito - Tran Van Khang of VinCSS (Member of Vingroup)",
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-099"
}
],
"trust": 0.7
},
"cve": "CVE-2021-22641",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.8,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2021-22641",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CNVD-2021-17707",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-22641",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2021-22641",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2021-22641",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "ZDI",
"id": "CVE-2021-22641",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2021-17707",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202101-2393",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2021-22641",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-099"
},
{
"db": "CNVD",
"id": "CNVD-2021-17707"
},
{
"db": "VULMON",
"id": "CVE-2021-22641"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002821"
},
{
"db": "NVD",
"id": "CVE-2021-22641"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2393"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22641"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002821"
},
{
"db": "ZDI",
"id": "ZDI-21-099"
},
{
"db": "CNVD",
"id": "CNVD-2021-17707"
},
{
"db": "VULMON",
"id": "CVE-2021-22641"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-22641",
"trust": 3.8
},
{
"db": "ZDI",
"id": "ZDI-21-099",
"trust": 3.2
},
{
"db": "ICS CERT",
"id": "ICSA-21-026-01",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU93293369",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002821",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-11669",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2021-17707",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2021.0297",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2393",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2021-22641",
"trust": 0.1
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-099"
},
{
"db": "CNVD",
"id": "CNVD-2021-17707"
},
{
"db": "VULMON",
"id": "CVE-2021-22641"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002821"
},
{
"db": "NVD",
"id": "CVE-2021-22641"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2393"
}
]
},
"id": "VAR-202101-1105",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-17707"
}
],
"trust": 1.53529412
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-17707"
}
]
},
"last_update_date": "2023-12-18T11:48:01.766000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.fujielectric.com/index.html"
},
{
"title": "Fuji Electric has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
},
{
"title": "Patch for Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite buffer overflow vulnerability (CNVD-2021-17707)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/252926"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-099"
},
{
"db": "CNVD",
"id": "CNVD-2021-17707"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002821"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-002821"
},
{
"db": "NVD",
"id": "CVE-2021-22641"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 4.4,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
},
{
"trust": 2.5,
"url": "https://www.zerodayinitiative.com/advisories/zdi-21-099/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-22641"
},
{
"trust": 0.8,
"url": "http://jvn.jp/vu/jvnvu93293369/index.html"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2021.0297/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-099"
},
{
"db": "CNVD",
"id": "CNVD-2021-17707"
},
{
"db": "VULMON",
"id": "CVE-2021-22641"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002821"
},
{
"db": "NVD",
"id": "CVE-2021-22641"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2393"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-21-099"
},
{
"db": "CNVD",
"id": "CNVD-2021-17707"
},
{
"db": "VULMON",
"id": "CVE-2021-22641"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002821"
},
{
"db": "NVD",
"id": "CVE-2021-22641"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2393"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-01-29T00:00:00",
"db": "ZDI",
"id": "ZDI-21-099"
},
{
"date": "2021-03-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-17707"
},
{
"date": "2021-01-27T00:00:00",
"db": "VULMON",
"id": "CVE-2021-22641"
},
{
"date": "2021-10-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-002821"
},
{
"date": "2021-01-27T20:15:13.207000",
"db": "NVD",
"id": "CVE-2021-22641"
},
{
"date": "2021-01-26T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2393"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-06-29T00:00:00",
"db": "ZDI",
"id": "ZDI-21-099"
},
{
"date": "2021-03-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-17707"
},
{
"date": "2021-01-29T00:00:00",
"db": "VULMON",
"id": "CVE-2021-22641"
},
{
"date": "2021-10-05T08:53:00",
"db": "JVNDB",
"id": "JVNDB-2021-002821"
},
{
"date": "2022-04-26T16:14:21.717000",
"db": "NVD",
"id": "CVE-2021-22641"
},
{
"date": "2021-02-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2393"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2393"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "V-Simulator\u00a0 and \u00a0V-Server\u00a0Lite\u00a0 Out-of-bounds Vulnerability in Microsoft",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-002821"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2393"
}
],
"trust": 0.6
}
}
VAR-202101-1104
Vulnerability from variot - Updated: 2023-12-18 11:18An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite There is a vulnerability in accessing uninitialized pointers.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper initialization of a pointer prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202101-1104",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "v-simulator",
"scope": "lt",
"trust": 1.0,
"vendor": "fujielectric",
"version": "4.0.10.0"
},
{
"model": "v-server",
"scope": "lt",
"trust": 1.0,
"vendor": "fujielectric",
"version": "4.0.10.0"
},
{
"model": "v-simulator",
"scope": "eq",
"trust": 0.8,
"vendor": "\u5bcc\u58eb\u96fb\u6a5f",
"version": "lite 4.0.10.0"
},
{
"model": "v-server",
"scope": null,
"trust": 0.8,
"vendor": "\u5bcc\u58eb\u96fb\u6a5f",
"version": null
},
{
"model": "v-server lite",
"scope": null,
"trust": 0.7,
"vendor": "fuji electric",
"version": null
},
{
"model": "electric tellus lite v-simulator",
"scope": "lt",
"trust": 0.6,
"vendor": "fuji",
"version": "4.0.10.0"
},
{
"model": "electric v-server lite",
"scope": "lt",
"trust": 0.6,
"vendor": "fuji",
"version": "4.0.10.0"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-098"
},
{
"db": "CNVD",
"id": "CNVD-2021-17708"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002820"
},
{
"db": "NVD",
"id": "CVE-2021-22639"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0.10.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0.10.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22639"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "khangkito - Tran Van Khang of VinCSS (Member of Vingroup)",
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-098"
}
],
"trust": 0.7
},
"cve": "CVE-2021-22639",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.8,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2021-22639",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CNVD-2021-17708",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-22639",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2021-22639",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2021-22639",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "ZDI",
"id": "CVE-2021-22639",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2021-17708",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202101-2398",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2021-22639",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-098"
},
{
"db": "CNVD",
"id": "CNVD-2021-17708"
},
{
"db": "VULMON",
"id": "CVE-2021-22639"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002820"
},
{
"db": "NVD",
"id": "CVE-2021-22639"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2398"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite There is a vulnerability in accessing uninitialized pointers.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper initialization of a pointer prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22639"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002820"
},
{
"db": "ZDI",
"id": "ZDI-21-098"
},
{
"db": "CNVD",
"id": "CNVD-2021-17708"
},
{
"db": "VULMON",
"id": "CVE-2021-22639"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-22639",
"trust": 3.8
},
{
"db": "ZDI",
"id": "ZDI-21-098",
"trust": 3.2
},
{
"db": "ICS CERT",
"id": "ICSA-21-026-01",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU93293369",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002820",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-11668",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2021-17708",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2021.0297",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2398",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2021-22639",
"trust": 0.1
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-098"
},
{
"db": "CNVD",
"id": "CNVD-2021-17708"
},
{
"db": "VULMON",
"id": "CVE-2021-22639"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002820"
},
{
"db": "NVD",
"id": "CVE-2021-22639"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2398"
}
]
},
"id": "VAR-202101-1104",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-17708"
}
],
"trust": 1.53529412
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-17708"
}
]
},
"last_update_date": "2023-12-18T11:18:29.815000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.fujielectric.com/index.html"
},
{
"title": "Fuji Electric has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
},
{
"title": "Patch for Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite buffer overflow vulnerability (CNVD-2021-17708)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/252906"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-098"
},
{
"db": "CNVD",
"id": "CNVD-2021-17708"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002820"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-824",
"trust": 1.0
},
{
"problemtype": "Accessing uninitialized pointers (CWE-824) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-002820"
},
{
"db": "NVD",
"id": "CVE-2021-22639"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 4.4,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
},
{
"trust": 2.5,
"url": "https://www.zerodayinitiative.com/advisories/zdi-21-098/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-22639"
},
{
"trust": 0.8,
"url": "http://jvn.jp/vu/jvnvu93293369/index.html"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2021.0297/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/824.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/195684"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-098"
},
{
"db": "CNVD",
"id": "CNVD-2021-17708"
},
{
"db": "VULMON",
"id": "CVE-2021-22639"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002820"
},
{
"db": "NVD",
"id": "CVE-2021-22639"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2398"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-21-098"
},
{
"db": "CNVD",
"id": "CNVD-2021-17708"
},
{
"db": "VULMON",
"id": "CVE-2021-22639"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002820"
},
{
"db": "NVD",
"id": "CVE-2021-22639"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2398"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-01-29T00:00:00",
"db": "ZDI",
"id": "ZDI-21-098"
},
{
"date": "2021-03-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-17708"
},
{
"date": "2021-01-27T00:00:00",
"db": "VULMON",
"id": "CVE-2021-22639"
},
{
"date": "2021-10-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-002820"
},
{
"date": "2021-01-27T20:15:12.847000",
"db": "NVD",
"id": "CVE-2021-22639"
},
{
"date": "2021-01-26T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2398"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-06-29T00:00:00",
"db": "ZDI",
"id": "ZDI-21-098"
},
{
"date": "2021-03-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-17708"
},
{
"date": "2021-01-29T00:00:00",
"db": "VULMON",
"id": "CVE-2021-22639"
},
{
"date": "2021-10-05T08:53:00",
"db": "JVNDB",
"id": "JVNDB-2021-002820"
},
{
"date": "2021-01-29T15:49:24.803000",
"db": "NVD",
"id": "CVE-2021-22639"
},
{
"date": "2021-02-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2398"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2398"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "V-Simulator\u00a0 and \u00a0V-Server\u00a0Lite\u00a0 Vulnerability in accessing uninitialized pointers in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-002820"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2398"
}
],
"trust": 0.6
}
}
VAR-202101-1103
Vulnerability from variot - Updated: 2023-12-18 11:16Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202101-1103",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "v-simulator",
"scope": "lt",
"trust": 1.0,
"vendor": "fujielectric",
"version": "4.0.10.0"
},
{
"model": "v-server",
"scope": "lt",
"trust": 1.0,
"vendor": "fujielectric",
"version": "4.0.10.0"
},
{
"model": "v-simulator",
"scope": "eq",
"trust": 0.8,
"vendor": "\u5bcc\u58eb\u96fb\u6a5f",
"version": "lite 4.0.10.0"
},
{
"model": "v-server",
"scope": null,
"trust": 0.8,
"vendor": "\u5bcc\u58eb\u96fb\u6a5f",
"version": null
},
{
"model": "v-server lite",
"scope": null,
"trust": 0.7,
"vendor": "fuji electric",
"version": null
},
{
"model": "electric tellus lite v-simulator",
"scope": "lt",
"trust": 0.6,
"vendor": "fuji",
"version": "4.0.10.0"
},
{
"model": "electric v-server lite",
"scope": "lt",
"trust": 0.6,
"vendor": "fuji",
"version": "4.0.10.0"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-097"
},
{
"db": "CNVD",
"id": "CNVD-2021-17711"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002819"
},
{
"db": "NVD",
"id": "CVE-2021-22637"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0.10.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0.10.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22637"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Anonymous",
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-097"
}
],
"trust": 0.7
},
"cve": "CVE-2021-22637",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.8,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2021-22637",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CNVD-2021-17711",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-22637",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2021-22637",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2021-22637",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "ZDI",
"id": "CVE-2021-22637",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2021-17711",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202101-2406",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2021-22637",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-097"
},
{
"db": "CNVD",
"id": "CNVD-2021-17711"
},
{
"db": "VULMON",
"id": "CVE-2021-22637"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002819"
},
{
"db": "NVD",
"id": "CVE-2021-22637"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2406"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22637"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002819"
},
{
"db": "ZDI",
"id": "ZDI-21-097"
},
{
"db": "CNVD",
"id": "CNVD-2021-17711"
},
{
"db": "VULMON",
"id": "CVE-2021-22637"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-22637",
"trust": 3.8
},
{
"db": "ZDI",
"id": "ZDI-21-097",
"trust": 3.2
},
{
"db": "ICS CERT",
"id": "ICSA-21-026-01",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU93293369",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002819",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-11170",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2021-17711",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2021.0297",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2406",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2021-22637",
"trust": 0.1
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-097"
},
{
"db": "CNVD",
"id": "CNVD-2021-17711"
},
{
"db": "VULMON",
"id": "CVE-2021-22637"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002819"
},
{
"db": "NVD",
"id": "CVE-2021-22637"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2406"
}
]
},
"id": "VAR-202101-1103",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-17711"
}
],
"trust": 1.53529412
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-17711"
}
]
},
"last_update_date": "2023-12-18T11:16:56.562000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.fujielectric.com/index.html"
},
{
"title": "Fuji Electric has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
},
{
"title": "Patch for Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite buffer overflow vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/252811"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-097"
},
{
"db": "CNVD",
"id": "CNVD-2021-17711"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002819"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-002819"
},
{
"db": "NVD",
"id": "CVE-2021-22637"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 4.4,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01"
},
{
"trust": 2.5,
"url": "https://www.zerodayinitiative.com/advisories/zdi-21-097/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-22637"
},
{
"trust": 0.8,
"url": "http://jvn.jp/vu/jvnvu93293369/index.html"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2021.0297/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-097"
},
{
"db": "CNVD",
"id": "CNVD-2021-17711"
},
{
"db": "VULMON",
"id": "CVE-2021-22637"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002819"
},
{
"db": "NVD",
"id": "CVE-2021-22637"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2406"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-21-097"
},
{
"db": "CNVD",
"id": "CNVD-2021-17711"
},
{
"db": "VULMON",
"id": "CVE-2021-22637"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-002819"
},
{
"db": "NVD",
"id": "CVE-2021-22637"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2406"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-01-29T00:00:00",
"db": "ZDI",
"id": "ZDI-21-097"
},
{
"date": "2021-03-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-17711"
},
{
"date": "2021-01-27T00:00:00",
"db": "VULMON",
"id": "CVE-2021-22637"
},
{
"date": "2021-10-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-002819"
},
{
"date": "2021-01-27T20:15:12.770000",
"db": "NVD",
"id": "CVE-2021-22637"
},
{
"date": "2021-01-26T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2406"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-01-29T00:00:00",
"db": "ZDI",
"id": "ZDI-21-097"
},
{
"date": "2021-03-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-17711"
},
{
"date": "2021-01-29T00:00:00",
"db": "VULMON",
"id": "CVE-2021-22637"
},
{
"date": "2021-10-05T08:53:00",
"db": "JVNDB",
"id": "JVNDB-2021-002819"
},
{
"date": "2022-04-26T16:14:06.040000",
"db": "NVD",
"id": "CVE-2021-22637"
},
{
"date": "2021-02-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2406"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2406"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "V-Simulator\u00a0 and \u00a0V-Server\u00a0Lite\u00a0 Out-of-bounds Vulnerability in Microsoft",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-002819"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2406"
}
],
"trust": 0.6
}
}
VAR-202004-2332
Vulnerability from variot - Updated: 2022-05-17 02:08This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202004-2332",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "v-server lite",
"scope": null,
"trust": 0.7,
"vendor": "fuji electric",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-453"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "kimiya",
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-453"
}
],
"trust": 0.7
},
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "ZDI-20-453",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "ZDI",
"id": "ZDI-20-453",
"trust": 0.7,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-453"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.",
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-453"
}
],
"trust": 0.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-10138",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-20-453",
"trust": 0.7
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-453"
}
]
},
"id": "VAR-202004-2332",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.41666666
},
"last_update_date": "2022-05-17T02:08:54.181000Z",
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-20-453"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-09T00:00:00",
"db": "ZDI",
"id": "ZDI-20-453"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-09T00:00:00",
"db": "ZDI",
"id": "ZDI-20-453"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Fuji Electric V-Server Lite VPR File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability",
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-453"
}
],
"trust": 0.7
}
}
VAR-202004-2333
Vulnerability from variot - Updated: 2022-05-17 01:43This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202004-2333",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "v-server lite",
"scope": null,
"trust": 0.7,
"vendor": "fuji electric",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-454"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "kimiya",
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-454"
}
],
"trust": 0.7
},
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "ZDI-20-454",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "ZDI",
"id": "ZDI-20-454",
"trust": 0.7,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-454"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.",
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-454"
}
],
"trust": 0.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-10137",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-20-454",
"trust": 0.7
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-454"
}
]
},
"id": "VAR-202004-2333",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.41666666
},
"last_update_date": "2022-05-17T01:43:05.050000Z",
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-20-454"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-09T00:00:00",
"db": "ZDI",
"id": "ZDI-20-454"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-09T00:00:00",
"db": "ZDI",
"id": "ZDI-20-454"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Fuji Electric V-Server Lite VPR File Parsing Out-Of-Bounds Read Remote Code Execution Vulnerability",
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-454"
}
],
"trust": 0.7
}
}
VAR-202102-0298
Vulnerability from variot - Updated: 2022-05-04 09:42The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code. Provided by Fuji Electric Co., Ltd. V-Server Lite Is an industrial software that collects production information in real time. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated data structure. An attacker can leverage this vulnerability to execute code in the context of the current process
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0298",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "v-server",
"scope": "lt",
"trust": 1.0,
"vendor": "fujielectric",
"version": "3.3.24.0"
},
{
"model": "v-server",
"scope": "eq",
"trust": 0.8,
"vendor": "fuji electric",
"version": "lite 3.3.24.0 \u306e\u5168\u3066"
},
{
"model": "v-server lite",
"scope": null,
"trust": 0.7,
"vendor": "fuji electric",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-1384"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009656"
},
{
"db": "NVD",
"id": "CVE-2020-25171"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.3.24.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-25171"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tran Van Khang - khangkito of VinCSS (Member of Vingroup)",
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-1384"
}
],
"trust": 0.7
},
"cve": "CVE-2020-25171",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CVE-2020-25171",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2020-25171",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "IPA score",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-009656",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2020-25171",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-25171",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "IPA",
"id": "JVNDB-2020-009656",
"trust": 0.8,
"value": "High"
},
{
"author": "ZDI",
"id": "CVE-2020-25171",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202011-1837",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-1384"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009656"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1837"
},
{
"db": "NVD",
"id": "CVE-2020-25171"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code. Provided by Fuji Electric Co., Ltd. V-Server Lite Is an industrial software that collects production information in real time. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated data structure. An attacker can leverage this vulnerability to execute code in the context of the current process",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-25171"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009656"
},
{
"db": "ZDI",
"id": "ZDI-20-1384"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-25171",
"trust": 3.1
},
{
"db": "ICS CERT",
"id": "ICSA-20-329-02",
"trust": 2.4
},
{
"db": "JVN",
"id": "JVNVU97620058",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009656",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-11353",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-20-1384",
"trust": 0.7
},
{
"db": "AUSCERT",
"id": "ESB-2020.4169",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1837",
"trust": 0.6
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-1384"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009656"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1837"
},
{
"db": "NVD",
"id": "CVE-2020-25171"
}
]
},
"id": "VAR-202102-0298",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.41666666
},
"last_update_date": "2022-05-04T09:42:08.814000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Fe Library | Search Remote Control Software Documents (\u8981\u30ed\u30b0\u30a4\u30f3)",
"trust": 0.8,
"url": "https://felib.fujielectric.co.jp/download/pod_document.htm?product1_id=p10003\u0026product2_id=p20023\u0026product3_id=p30262\u0026material1_id=m10009\u0026site=global\u0026lang=en"
},
{
"title": "Fuji Electric has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-1384"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009656"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009656"
},
{
"db": "NVD",
"id": "CVE-2020-25171"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-25171"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu97620058"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-25171"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.4169/"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-1384"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009656"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1837"
},
{
"db": "NVD",
"id": "CVE-2020-25171"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-20-1384"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009656"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1837"
},
{
"db": "NVD",
"id": "CVE-2020-25171"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-11-25T00:00:00",
"db": "ZDI",
"id": "ZDI-20-1384"
},
{
"date": "2020-11-26T06:26:17",
"db": "JVNDB",
"id": "JVNDB-2020-009656"
},
{
"date": "2020-11-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202011-1837"
},
{
"date": "2021-02-19T18:15:00",
"db": "NVD",
"id": "CVE-2020-25171"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-11-25T00:00:00",
"db": "ZDI",
"id": "ZDI-20-1384"
},
{
"date": "2020-11-26T06:26:17",
"db": "JVNDB",
"id": "JVNDB-2020-009656"
},
{
"date": "2021-02-26T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202011-1837"
},
{
"date": "2021-02-25T22:16:00",
"db": "NVD",
"id": "CVE-2020-25171"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202011-1837"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Made by Fuji Electric V-Server Lite Out-of-bounds write vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009656"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202011-1837"
}
],
"trust": 0.6
}
}
VAR-202004-0059
Vulnerability from variot - Updated: 2022-05-04 09:21Fuji Electric V-Server Lite all versions prior to 4.0.9.0 contains a heap based buffer overflow. The buffer allocated to read data, when parsing VPR files, is too small. Provided by Fuji Electric Co., Ltd. V-Server Lite Is an industrial software that collects production information in real time. V-Server Lite To VPR File ( Project file ) Heap-based buffer overflow vulnerability due to too small buffer size allocated when reading (CWE-122) Exists.A remote attacker could elevate privileges and execute arbitrary code. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202004-0059",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "v-server lite",
"scope": null,
"trust": 1.4,
"vendor": "fuji electric",
"version": null
},
{
"model": "v-server",
"scope": "lt",
"trust": 1.0,
"vendor": "fujielectric",
"version": "4.0.9.0"
},
{
"model": "v-server",
"scope": "eq",
"trust": 0.8,
"vendor": "fuji electric",
"version": "lite 4.0.9.0 \u306e\u5168\u3066"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-451"
},
{
"db": "ZDI",
"id": "ZDI-20-452"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003280"
},
{
"db": "NVD",
"id": "CVE-2020-10646"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0.9.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-10646"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "kimiya",
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-451"
},
{
"db": "ZDI",
"id": "ZDI-20-452"
}
],
"trust": 1.4
},
"cve": "CVE-2020-10646",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CVE-2020-10646",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2020-10646",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.4,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2020-10646",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "IPA score",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-003280",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "ZDI",
"id": "CVE-2020-10646",
"trust": 1.4,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2020-10646",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "IPA",
"id": "JVNDB-2020-003280",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202004-374",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-451"
},
{
"db": "ZDI",
"id": "ZDI-20-452"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003280"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-374"
},
{
"db": "NVD",
"id": "CVE-2020-10646"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Fuji Electric V-Server Lite all versions prior to 4.0.9.0 contains a heap based buffer overflow. The buffer allocated to read data, when parsing VPR files, is too small. Provided by Fuji Electric Co., Ltd. V-Server Lite Is an industrial software that collects production information in real time. V-Server Lite To VPR File ( Project file ) Heap-based buffer overflow vulnerability due to too small buffer size allocated when reading (CWE-122) Exists.A remote attacker could elevate privileges and execute arbitrary code. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-10646"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003280"
},
{
"db": "ZDI",
"id": "ZDI-20-451"
},
{
"db": "ZDI",
"id": "ZDI-20-452"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-10646",
"trust": 3.8
},
{
"db": "ICS CERT",
"id": "ICSA-20-098-04",
"trust": 2.4
},
{
"db": "ZDI",
"id": "ZDI-20-452",
"trust": 1.3
},
{
"db": "JVN",
"id": "JVNVU98887141",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003280",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-10119",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-20-451",
"trust": 0.7
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-10120",
"trust": 0.7
},
{
"db": "NSFOCUS",
"id": "47584",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "47741",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2020.1254",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202004-374",
"trust": 0.6
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-451"
},
{
"db": "ZDI",
"id": "ZDI-20-452"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003280"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-374"
},
{
"db": "NVD",
"id": "CVE-2020-10646"
}
]
},
"id": "VAR-202004-0059",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.41666666
},
"last_update_date": "2022-05-04T09:21:58.233000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Fuji Electric has issued an update to correct this vulnerability.",
"trust": 1.4,
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-098-04"
},
{
"title": "Fe Library",
"trust": 0.8,
"url": "https://felib.fujielectric.co.jp/download/pod_document.htm?product1_id=p10003\u0026product2_id=p20023\u0026product3_id=p30262\u0026material1_id=m10009\u0026site=global\u0026lang=en"
},
{
"title": "Fuji Electric V-Server Lite Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=115595"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-451"
},
{
"db": "ZDI",
"id": "ZDI-20-452"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003280"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-374"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "CWE-122",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-003280"
},
{
"db": "NVD",
"id": "CVE-2020-10646"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.8,
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-098-04"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-10646"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu98887141/index.html"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/47741"
},
{
"trust": 0.6,
"url": "https://www.zerodayinitiative.com/advisories/zdi-20-452/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-10646"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.1254/"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/47584"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-451"
},
{
"db": "ZDI",
"id": "ZDI-20-452"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003280"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-374"
},
{
"db": "NVD",
"id": "CVE-2020-10646"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-20-451"
},
{
"db": "ZDI",
"id": "ZDI-20-452"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003280"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-374"
},
{
"db": "NVD",
"id": "CVE-2020-10646"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-09T00:00:00",
"db": "ZDI",
"id": "ZDI-20-451"
},
{
"date": "2020-04-09T00:00:00",
"db": "ZDI",
"id": "ZDI-20-452"
},
{
"date": "2020-04-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-003280"
},
{
"date": "2020-04-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202004-374"
},
{
"date": "2020-04-13T19:15:00",
"db": "NVD",
"id": "CVE-2020-10646"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-09T00:00:00",
"db": "ZDI",
"id": "ZDI-20-451"
},
{
"date": "2020-04-09T00:00:00",
"db": "ZDI",
"id": "ZDI-20-452"
},
{
"date": "2020-04-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-003280"
},
{
"date": "2020-08-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202004-374"
},
{
"date": "2020-04-13T20:11:00",
"db": "NVD",
"id": "CVE-2020-10646"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-374"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Fuji Electric V-Server Lite VPR File Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability",
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-451"
},
{
"db": "ZDI",
"id": "ZDI-20-452"
}
],
"trust": 1.4
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-374"
}
],
"trust": 0.6
}
}
CVE-2021-38419 (GCVE-0-2021-38419)
Vulnerability from cvelistv5 – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44- CWE-787 - Out-of-bounds Write
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
unspecified , < 4.0.12.0
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.450Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Tellus Lite V-Simulator",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-20T20:08:50",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
},
"title": " Fuji Electric Tellus Lite V-Simulator out of bounds write",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-38419",
"STATE": "PUBLIC",
"TITLE": " Fuji Electric Tellus Lite V-Simulator out of bounds write"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
},
{
"product_name": "Tellus Lite V-Simulator",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
}
]
},
"vendor_name": " Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787 Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38419",
"datePublished": "2021-12-20T20:08:50",
"dateReserved": "2021-08-10T00:00:00",
"dateUpdated": "2024-08-04T01:44:22.450Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38413 (GCVE-0-2021-38413)
Vulnerability from cvelistv5 – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44- CWE-121 - Stack-based Buffer Overflow
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
unspecified , < 4.0.12.0
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.252Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Tellus Lite V-Simulator",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-20T20:08:49",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
},
"title": " Fuji Electric Tellus Lite V-Simulator stack based buffer overflow",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-38413",
"STATE": "PUBLIC",
"TITLE": " Fuji Electric Tellus Lite V-Simulator stack based buffer overflow"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
},
{
"product_name": "Tellus Lite V-Simulator",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
}
]
},
"vendor_name": " Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121 Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38413",
"datePublished": "2021-12-20T20:08:49",
"dateReserved": "2021-08-10T00:00:00",
"dateUpdated": "2024-08-04T01:44:22.252Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38415 (GCVE-0-2021-38415)
Vulnerability from cvelistv5 – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44- CWE-122 - Heap-based Buffer Overflow
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
unspecified , < 4.0.12.0
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.244Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Tellus Lite V-Simulator",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-20T20:08:48",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
},
"title": " Fuji Electric Tellus Lite V-Simulator heap based buffer overflow",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-38415",
"STATE": "PUBLIC",
"TITLE": " Fuji Electric Tellus Lite V-Simulator heap based buffer overflow"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
},
{
"product_name": "Tellus Lite V-Simulator",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
}
]
},
"vendor_name": " Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122 Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38415",
"datePublished": "2021-12-20T20:08:48",
"dateReserved": "2021-08-10T00:00:00",
"dateUpdated": "2024-08-04T01:44:22.244Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38421 (GCVE-0-2021-38421)
Vulnerability from cvelistv5 – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44- CWE-125 - Out-of-bounds Read
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
unspecified , < 4.0.12.0
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.159Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Tellus Lite V-Simulator",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-20T20:08:48",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
},
"title": " Fuji Electric Tellus Lite V-Simulator out of bounds read",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-38421",
"STATE": "PUBLIC",
"TITLE": " Fuji Electric Tellus Lite V-Simulator out of bounds read"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
},
{
"product_name": "Tellus Lite V-Simulator",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
}
]
},
"vendor_name": " Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125 Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38421",
"datePublished": "2021-12-20T20:08:48",
"dateReserved": "2021-08-10T00:00:00",
"dateUpdated": "2024-08-04T01:44:22.159Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38401 (GCVE-0-2021-38401)
Vulnerability from cvelistv5 – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:37- CWE-822 - - Untrusted pointer dereference
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
unspecified , < 4.0.12.0
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:37:16.513Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Tellus Lite V-Simulator",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-822",
"description": "CWE-822 - Untrusted pointer dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-20T20:08:47",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
},
"title": " Fuji Electric Tellus Lite V-Simulator untrusted pointer dereference",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-38401",
"STATE": "PUBLIC",
"TITLE": " Fuji Electric Tellus Lite V-Simulator untrusted pointer dereference"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
},
{
"product_name": "Tellus Lite V-Simulator",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
}
]
},
"vendor_name": " Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-822 - Untrusted pointer dereference"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38401",
"datePublished": "2021-12-20T20:08:47",
"dateReserved": "2021-08-10T00:00:00",
"dateUpdated": "2024-08-04T01:37:16.513Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38409 (GCVE-0-2021-38409)
Vulnerability from cvelistv5 – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:37- CWE-824 - Access of Uninitialized Pointer
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
unspecified , < 4.0.12.0
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:37:16.652Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Tellus Lite V-Simulator",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-824",
"description": "CWE-824 Access of Uninitialized Pointer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-20T20:08:46",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
},
"title": " Fuji Electric Tellus Lite V-Simulator uninitialized pointer",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-38409",
"STATE": "PUBLIC",
"TITLE": " Fuji Electric Tellus Lite V-Simulator uninitialized pointer"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
},
{
"product_name": "Tellus Lite V-Simulator",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
}
]
},
"vendor_name": " Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-824 Access of Uninitialized Pointer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38409",
"datePublished": "2021-12-20T20:08:46",
"dateReserved": "2021-08-10T00:00:00",
"dateUpdated": "2024-08-04T01:37:16.652Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25171 (GCVE-0-2020-25171)
Vulnerability from cvelistv5 – Published: 2021-02-19 17:06 – Updated: 2024-08-04 15:26- CWE-787 - OUT-OF-BOUNDS WRITE CWE-787
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
unspecified , < 3.3.24.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:10.248Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": "Fuji Electric",
"versions": [
{
"lessThan": "3.3.24.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "OUT-OF-BOUNDS WRITE CWE-787",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-19T17:06:18",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
}
],
"source": {
"advisory": "ICSA-20-329-02",
"discovery": "UNKNOWN"
},
"title": "Fuji Electric V-Server Lite",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-25171",
"STATE": "PUBLIC",
"TITLE": "Fuji Electric V-Server Lite"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "3.3.24.0"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "OUT-OF-BOUNDS WRITE CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
}
]
},
"source": {
"advisory": "ICSA-20-329-02",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25171",
"datePublished": "2021-02-19T17:06:18",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-08-04T15:26:10.248Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-10637 (GCVE-0-2018-10637)
Vulnerability from cvelistv5 – Published: 2018-09-13 20:00 – Updated: 2024-09-17 01:11- CWE-120 - BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-120
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
4.0.3.0 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T07:46:47.265Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105328",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105328"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": "Fuji Electric",
"versions": [
{
"status": "affected",
"version": "4.0.3.0 and prior"
}
]
}
],
"datePublic": "2018-09-11T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (\u0027CLASSIC BUFFER OVERFLOW\u0027) CWE-120",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-09-14T09:57:02",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "105328",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105328"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-09-11T00:00:00",
"ID": "CVE-2018-10637",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_value": "4.0.3.0 and prior"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (\u0027CLASSIC BUFFER OVERFLOW\u0027) CWE-120"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105328",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105328"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-10637",
"datePublished": "2018-09-13T20:00:00Z",
"dateReserved": "2018-05-01T00:00:00",
"dateUpdated": "2024-09-17T01:11:13.766Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38419 (GCVE-0-2021-38419)
Vulnerability from nvd – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44- CWE-787 - Out-of-bounds Write
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
unspecified , < 4.0.12.0
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.450Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Tellus Lite V-Simulator",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-20T20:08:50",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
},
"title": " Fuji Electric Tellus Lite V-Simulator out of bounds write",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-38419",
"STATE": "PUBLIC",
"TITLE": " Fuji Electric Tellus Lite V-Simulator out of bounds write"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
},
{
"product_name": "Tellus Lite V-Simulator",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
}
]
},
"vendor_name": " Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, which can result in data corruption, a system crash, or code execution."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787 Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38419",
"datePublished": "2021-12-20T20:08:50",
"dateReserved": "2021-08-10T00:00:00",
"dateUpdated": "2024-08-04T01:44:22.450Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38413 (GCVE-0-2021-38413)
Vulnerability from nvd – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44- CWE-121 - Stack-based Buffer Overflow
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
unspecified , < 4.0.12.0
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.252Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Tellus Lite V-Simulator",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-20T20:08:49",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
},
"title": " Fuji Electric Tellus Lite V-Simulator stack based buffer overflow",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-38413",
"STATE": "PUBLIC",
"TITLE": " Fuji Electric Tellus Lite V-Simulator stack based buffer overflow"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
},
{
"product_name": "Tellus Lite V-Simulator",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
}
]
},
"vendor_name": " Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121 Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38413",
"datePublished": "2021-12-20T20:08:49",
"dateReserved": "2021-08-10T00:00:00",
"dateUpdated": "2024-08-04T01:44:22.252Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38415 (GCVE-0-2021-38415)
Vulnerability from nvd – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44- CWE-122 - Heap-based Buffer Overflow
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
unspecified , < 4.0.12.0
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.244Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Tellus Lite V-Simulator",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-20T20:08:48",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
},
"title": " Fuji Electric Tellus Lite V-Simulator heap based buffer overflow",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-38415",
"STATE": "PUBLIC",
"TITLE": " Fuji Electric Tellus Lite V-Simulator heap based buffer overflow"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
},
{
"product_name": "Tellus Lite V-Simulator",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
}
]
},
"vendor_name": " Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable a heap-based buffer overflow when parsing a specially crafted project file, which may allow an attacker to execute arbitrary code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122 Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38415",
"datePublished": "2021-12-20T20:08:48",
"dateReserved": "2021-08-10T00:00:00",
"dateUpdated": "2024-08-04T01:44:22.244Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38421 (GCVE-0-2021-38421)
Vulnerability from nvd – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:44- CWE-125 - Out-of-bounds Read
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
unspecified , < 4.0.12.0
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:22.159Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Tellus Lite V-Simulator",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-20T20:08:48",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
},
"title": " Fuji Electric Tellus Lite V-Simulator out of bounds read",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-38421",
"STATE": "PUBLIC",
"TITLE": " Fuji Electric Tellus Lite V-Simulator out of bounds read"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
},
{
"product_name": "Tellus Lite V-Simulator",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
}
]
},
"vendor_name": " Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125 Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38421",
"datePublished": "2021-12-20T20:08:48",
"dateReserved": "2021-08-10T00:00:00",
"dateUpdated": "2024-08-04T01:44:22.159Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38401 (GCVE-0-2021-38401)
Vulnerability from nvd – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:37- CWE-822 - - Untrusted pointer dereference
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
unspecified , < 4.0.12.0
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:37:16.513Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Tellus Lite V-Simulator",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-822",
"description": "CWE-822 - Untrusted pointer dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-20T20:08:47",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
},
"title": " Fuji Electric Tellus Lite V-Simulator untrusted pointer dereference",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-38401",
"STATE": "PUBLIC",
"TITLE": " Fuji Electric Tellus Lite V-Simulator untrusted pointer dereference"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
},
{
"product_name": "Tellus Lite V-Simulator",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
}
]
},
"vendor_name": " Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-822 - Untrusted pointer dereference"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38401",
"datePublished": "2021-12-20T20:08:47",
"dateReserved": "2021-08-10T00:00:00",
"dateUpdated": "2024-08-04T01:37:16.513Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38409 (GCVE-0-2021-38409)
Vulnerability from nvd – Published: 2021-12-20 20:08 – Updated: 2024-08-04 01:37- CWE-824 - Access of Uninitialized Pointer
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
unspecified , < 4.0.12.0
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:37:16.652Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Tellus Lite V-Simulator",
"vendor": " Fuji Electric",
"versions": [
{
"lessThan": "4.0.12.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-824",
"description": "CWE-824 Access of Uninitialized Pointer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-20T20:08:46",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
},
"title": " Fuji Electric Tellus Lite V-Simulator uninitialized pointer",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-38409",
"STATE": "PUBLIC",
"TITLE": " Fuji Electric Tellus Lite V-Simulator uninitialized pointer"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
},
{
"product_name": "Tellus Lite V-Simulator",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0.12.0"
}
]
}
}
]
},
"vendor_name": " Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an access of uninitialized pointer, which may allow an attacker read from or write to unexpected memory locations, leading to a denial-of-service."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-824 Access of Uninitialized Pointer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
}
],
"source": {
"advisory": "ICSA-21-299-01",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38409",
"datePublished": "2021-12-20T20:08:46",
"dateReserved": "2021-08-10T00:00:00",
"dateUpdated": "2024-08-04T01:37:16.652Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25171 (GCVE-0-2020-25171)
Vulnerability from nvd – Published: 2021-02-19 17:06 – Updated: 2024-08-04 15:26- CWE-787 - OUT-OF-BOUNDS WRITE CWE-787
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
unspecified , < 3.3.24.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:10.248Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": "Fuji Electric",
"versions": [
{
"lessThan": "3.3.24.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "OUT-OF-BOUNDS WRITE CWE-787",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-19T17:06:18",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
}
],
"source": {
"advisory": "ICSA-20-329-02",
"discovery": "UNKNOWN"
},
"title": "Fuji Electric V-Server Lite",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-25171",
"STATE": "PUBLIC",
"TITLE": "Fuji Electric V-Server Lite"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "3.3.24.0"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "OUT-OF-BOUNDS WRITE CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-02"
}
]
},
"source": {
"advisory": "ICSA-20-329-02",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25171",
"datePublished": "2021-02-19T17:06:18",
"dateReserved": "2020-09-04T00:00:00",
"dateUpdated": "2024-08-04T15:26:10.248Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-10637 (GCVE-0-2018-10637)
Vulnerability from nvd – Published: 2018-09-13 20:00 – Updated: 2024-09-17 01:11- CWE-120 - BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-120
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | V-Server Lite |
Affected:
4.0.3.0 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T07:46:47.265Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105328",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105328"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "V-Server Lite",
"vendor": "Fuji Electric",
"versions": [
{
"status": "affected",
"version": "4.0.3.0 and prior"
}
]
}
],
"datePublic": "2018-09-11T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (\u0027CLASSIC BUFFER OVERFLOW\u0027) CWE-120",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-09-14T09:57:02",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "105328",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105328"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-09-11T00:00:00",
"ID": "CVE-2018-10637",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "V-Server Lite",
"version": {
"version_data": [
{
"version_value": "4.0.3.0 and prior"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (\u0027CLASSIC BUFFER OVERFLOW\u0027) CWE-120"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105328",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105328"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-254-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-10637",
"datePublished": "2018-09-13T20:00:00Z",
"dateReserved": "2018-05-01T00:00:00",
"dateUpdated": "2024-09-17T01:11:13.766Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}