cve-2021-38413
Vulnerability from cvelistv5
Published
2021-12-20 20:08
Modified
2024-08-04 01:44
Summary
Fuji Electric Tellus Lite V-Simulator stack based buffer overflow
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01Patch, Third Party Advisory, US Government Resource
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.252Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-Server Lite",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Tellus Lite V-Simulator",
          "vendor": " Fuji Electric",
          "versions": [
            {
              "lessThan": "4.0.12.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-20T20:08:49",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
        }
      ],
      "source": {
        "advisory": "ICSA-21-299-01",
        "discovery": "EXTERNAL"
      },
      "title": " Fuji Electric Tellus Lite V-Simulator stack based buffer overflow",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-38413",
          "STATE": "PUBLIC",
          "TITLE": " Fuji Electric Tellus Lite V-Simulator stack based buffer overflow"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "V-Server Lite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Tellus Lite V-Simulator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0.12.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": " Fuji Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya, working with Trend Micro\u2019s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121 Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"
          }
        ],
        "source": {
          "advisory": "ICSA-21-299-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38413",
    "datePublished": "2021-12-20T20:08:49",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:44:22.252Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-38413\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2021-12-20T21:15:08.440\",\"lastModified\":\"2021-12-27T20:28:50.440\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to a stack-based buffer overflow, which may allow an attacker to achieve code execution.\"},{\"lang\":\"es\",\"value\":\"Fuji Electric V-Server Lite y Tellus Lite V-Simulator versiones anteriores a 4.0.12.0, son vulnerables a un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria, que puede permitir a un atacante una ejecuci\u00f3n de c\u00f3digo\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*\",\"versionEndExcluding\":\"4.0.12.0\",\"matchCriteriaId\":\"BDE5CC23-7376-4E69-988E-42719159E52C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*\",\"versionEndExcluding\":\"4.0.12.0\",\"matchCriteriaId\":\"1A6F4C85-64D7-4F4A-8652-5D4B6F8E6914\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\",\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.