var-202101-1105
Vulnerability from variot
A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202101-1105", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "v-simulator", "scope": "lt", "trust": 1.0, "vendor": "fujielectric", "version": "4.0.10.0" }, { "model": "v-server", "scope": "lt", "trust": 1.0, "vendor": "fujielectric", "version": "4.0.10.0" }, { "model": "v-simulator", "scope": "eq", "trust": 0.8, "vendor": "\u5bcc\u58eb\u96fb\u6a5f", "version": "lite 4.0.10.0" }, { "model": "v-server", "scope": null, "trust": 0.8, "vendor": "\u5bcc\u58eb\u96fb\u6a5f", "version": null }, { "model": "v-server lite", "scope": null, "trust": 0.7, "vendor": "fuji electric", "version": null }, { "model": "electric tellus lite v-simulator", "scope": "lt", "trust": 0.6, "vendor": "fuji", "version": "4.0.10.0" }, { "model": "electric v-server lite", "scope": "lt", "trust": 0.6, "vendor": "fuji", "version": "4.0.10.0" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-099" }, { "db": "CNVD", "id": "CNVD-2021-17707" }, { "db": "JVNDB", "id": "JVNDB-2021-002821" }, { "db": "NVD", "id": "CVE-2021-22641" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0.10.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0.10.0", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-22641" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "khangkito - Tran Van Khang of VinCSS (Member of Vingroup)", "sources": [ { "db": "ZDI", "id": "ZDI-21-099" } ], "trust": 0.7 }, "cve": "CVE-2021-22641", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-22641", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CNVD-2021-17707", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-22641", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-22641", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 0.7, "userInteraction": "REQUIRED", "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-22641", "trust": 1.8, "value": "HIGH" }, { "author": "ZDI", "id": "CVE-2021-22641", "trust": 0.7, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2021-17707", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202101-2393", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-22641", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-099" }, { "db": "CNVD", "id": "CNVD-2021-17707" }, { "db": "VULMON", "id": "CVE-2021-22641" }, { "db": "JVNDB", "id": "JVNDB-2021-002821" }, { "db": "NVD", "id": "CVE-2021-22641" }, { "db": "CNNVD", "id": "CNNVD-202101-2393" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). V-Simulator and V-Server Lite Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric V-Server Lite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of VPR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite are both products of Fuji Electric, Japan. The software can collect information about PLCs, temperature controllers, inverters and other equipment", "sources": [ { "db": "NVD", "id": "CVE-2021-22641" }, { "db": "JVNDB", "id": "JVNDB-2021-002821" }, { "db": "ZDI", "id": "ZDI-21-099" }, { "db": "CNVD", "id": "CNVD-2021-17707" }, { "db": "VULMON", "id": "CVE-2021-22641" } ], "trust": 2.88 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-22641", "trust": 3.8 }, { "db": "ZDI", "id": "ZDI-21-099", "trust": 3.2 }, { "db": "ICS CERT", "id": "ICSA-21-026-01", "trust": 3.1 }, { "db": "JVN", "id": "JVNVU93293369", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-002821", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-11669", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2021-17707", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.0297", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202101-2393", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-22641", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-099" }, { "db": "CNVD", "id": "CNVD-2021-17707" }, { "db": "VULMON", "id": "CVE-2021-22641" }, { "db": "JVNDB", "id": "JVNDB-2021-002821" }, { "db": "NVD", "id": "CVE-2021-22641" }, { "db": "CNNVD", "id": "CNNVD-202101-2393" } ] }, "id": "VAR-202101-1105", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-17707" } ], "trust": 1.53529412 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-17707" } ] }, "last_update_date": "2023-12-18T11:48:01.766000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.fujielectric.com/index.html" }, { "title": "Fuji Electric has issued an update to correct this vulnerability.", "trust": 0.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01" }, { "title": "Patch for Fuji Electric Tellus Lite V-Simulator and Fuji Electric V-Server Lite buffer overflow vulnerability (CNVD-2021-17707)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/252926" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-099" }, { "db": "CNVD", "id": "CNVD-2021-17707" }, { "db": "JVNDB", "id": "JVNDB-2021-002821" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-002821" }, { "db": "NVD", "id": "CVE-2021-22641" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 4.4, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-026-01" }, { "trust": 2.5, "url": "https://www.zerodayinitiative.com/advisories/zdi-21-099/" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-22641" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu93293369/index.html" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.0297/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-099" }, { "db": "CNVD", "id": "CNVD-2021-17707" }, { "db": "VULMON", "id": "CVE-2021-22641" }, { "db": "JVNDB", "id": "JVNDB-2021-002821" }, { "db": "NVD", "id": "CVE-2021-22641" }, { "db": "CNNVD", "id": "CNNVD-202101-2393" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "ZDI", "id": "ZDI-21-099" }, { "db": "CNVD", "id": "CNVD-2021-17707" }, { "db": "VULMON", "id": "CVE-2021-22641" }, { "db": "JVNDB", "id": "JVNDB-2021-002821" }, { "db": "NVD", "id": "CVE-2021-22641" }, { "db": "CNNVD", "id": "CNNVD-202101-2393" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-01-29T00:00:00", "db": "ZDI", "id": "ZDI-21-099" }, { "date": "2021-03-16T00:00:00", "db": "CNVD", "id": "CNVD-2021-17707" }, { "date": "2021-01-27T00:00:00", "db": "VULMON", "id": "CVE-2021-22641" }, { "date": "2021-10-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-002821" }, { "date": "2021-01-27T20:15:13.207000", "db": "NVD", "id": "CVE-2021-22641" }, { "date": "2021-01-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2393" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-29T00:00:00", "db": "ZDI", "id": "ZDI-21-099" }, { "date": "2021-03-16T00:00:00", "db": "CNVD", "id": "CNVD-2021-17707" }, { "date": "2021-01-29T00:00:00", "db": "VULMON", "id": "CVE-2021-22641" }, { "date": "2021-10-05T08:53:00", "db": "JVNDB", "id": "JVNDB-2021-002821" }, { "date": "2022-04-26T16:14:21.717000", "db": "NVD", "id": "CVE-2021-22641" }, { "date": "2021-02-01T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2393" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2393" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "V-Simulator\u00a0 and \u00a0V-Server\u00a0Lite\u00a0 Out-of-bounds Vulnerability in Microsoft", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-002821" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2393" } ], "trust": 0.6 } }
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.