Search criteria

27 vulnerabilities found for kepserver_enterprise by rockwellautomation

FKIE_CVE-2023-5909

Vulnerability from fkie_nvd - Published: 2023-11-30 22:15 - Updated: 2024-11-21 08:42
Summary
KEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:industrial_gateway_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FAC36939-C47F-4426-A684-0252C014CB05",
              "versionEndIncluding": "7.614",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:keepserverex:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C003AF3-3140-4AD9-8407-D3C216D72AA0",
              "versionEndIncluding": "6.14.263.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:opc-aggregator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0A4FE5D-D1DD-4854-B709-3E0A54D6BE97",
              "versionEndIncluding": "6.14",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D01A814D-8F2B-4B88-A66B-F2A2C293A6AB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_edge:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8B99ED4-CEB0-463D-9900-426C6108A009",
              "versionEndIncluding": "1.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "14930935-3DE4-403F-9F6A-9E4490C3B95D",
              "versionEndIncluding": "6.14.263.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "40663AD6-24DE-4D75-AA95-0D4E6A2ADF04",
              "versionEndIncluding": "6.14.263.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:softwaretoolbox:top_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB7C7A8B-38A0-4A48-B78A-F5FAA2A9E20F",
              "versionEndIncluding": "6.14.263.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "\n\n\n\n\n\n\n\n\nKEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.\n\n\n\n\n\n\n\n"
    },
    {
      "lang": "es",
      "value": "KEPServerEX no valida adecuadamente los certificados de los clientes, lo que puede permitir que se conecten usuarios no autenticados."
    }
  ],
  "id": "CVE-2023-5909",
  "lastModified": "2024-11-21T08:42:45.260",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-11-30T22:15:10.163",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-297"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-295"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2023-5908

Vulnerability from fkie_nvd - Published: 2023-11-30 22:15 - Updated: 2024-11-21 08:42
Summary
KEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:industrial_gateway_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FAC36939-C47F-4426-A684-0252C014CB05",
              "versionEndIncluding": "7.614",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:keepserverex:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C003AF3-3140-4AD9-8407-D3C216D72AA0",
              "versionEndIncluding": "6.14.263.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:opc-aggregator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0A4FE5D-D1DD-4854-B709-3E0A54D6BE97",
              "versionEndIncluding": "6.14",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D01A814D-8F2B-4B88-A66B-F2A2C293A6AB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_edge:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8B99ED4-CEB0-463D-9900-426C6108A009",
              "versionEndIncluding": "1.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "14930935-3DE4-403F-9F6A-9E4490C3B95D",
              "versionEndIncluding": "6.14.263.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "40663AD6-24DE-4D75-AA95-0D4E6A2ADF04",
              "versionEndIncluding": "6.14.263.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:softwaretoolbox:top_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB7C7A8B-38A0-4A48-B78A-F5FAA2A9E20F",
              "versionEndIncluding": "6.14.263.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "\n\n\n\n\nKEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.\n\n\n\n\n"
    },
    {
      "lang": "es",
      "value": "KEPServerEX es vulnerable a un desbordamiento del b\u00fafer que puede permitir que un atacante bloquee el producto al que se accede o filtre informaci\u00f3n."
    }
  ],
  "id": "CVE-2023-5908",
  "lastModified": "2024-11-21T08:42:45.123",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.2,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-11-30T22:15:09.923",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2022-2848

Vulnerability from fkie_nvd - Published: 2023-03-29 19:15 - Updated: 2025-02-18 17:15
Severity ?
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16486.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:industrial_gateway_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "864CE1B5-7A33-4BFF-955C-7ACC95670A78",
              "versionEndExcluding": "7.612",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:kepware_kepserverex:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F1B40A2-8747-42B6-BBBB-A7E805143FC5",
              "versionEndExcluding": "6.12",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:opc-aggregator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "243853C3-04C4-4FA6-89E4-15A55D00B251",
              "versionEndExcluding": "6.12",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D01A814D-8F2B-4B88-A66B-F2A2C293A6AB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_edge:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F732A00C-F341-4048-9FFD-E866A7DE50A3",
              "versionEndExcluding": "1.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E4343161-DCB8-4DD3-8EA6-BC8B40FC6103",
              "versionEndExcluding": "6.12",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1718A22-3F3F-4523-AC36-6408929903AD",
              "versionEndExcluding": "6.12",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:softwaretoolbox:top_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB1AD52B-9FB3-4C97-9987-059B398A1794",
              "versionEndExcluding": "6.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16486."
    }
  ],
  "id": "CVE-2022-2848",
  "lastModified": "2025-02-18T17:15:13.367",
  "metrics": {
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.2,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-03-29T19:15:11.680",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1454/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1454/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2022-2825

Vulnerability from fkie_nvd - Published: 2023-03-29 19:15 - Updated: 2025-02-18 17:15
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:industrial_gateway_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "864CE1B5-7A33-4BFF-955C-7ACC95670A78",
              "versionEndExcluding": "7.612",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:kepware_kepserverex:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F1B40A2-8747-42B6-BBBB-A7E805143FC5",
              "versionEndExcluding": "6.12",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:opc-aggregator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "243853C3-04C4-4FA6-89E4-15A55D00B251",
              "versionEndExcluding": "6.12",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D01A814D-8F2B-4B88-A66B-F2A2C293A6AB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_edge:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F732A00C-F341-4048-9FFD-E866A7DE50A3",
              "versionEndExcluding": "1.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E4343161-DCB8-4DD3-8EA6-BC8B40FC6103",
              "versionEndExcluding": "6.12",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1718A22-3F3F-4523-AC36-6408929903AD",
              "versionEndExcluding": "6.12",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:softwaretoolbox:top_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB1AD52B-9FB3-4C97-9987-059B398A1794",
              "versionEndExcluding": "6.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411."
    }
  ],
  "id": "CVE-2022-2825",
  "lastModified": "2025-02-18T17:15:13.183",
  "metrics": {
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2023-03-29T19:15:11.610",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1455/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1455/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2023-0755

Vulnerability from fkie_nvd - Published: 2023-02-23 22:15 - Updated: 2024-11-21 07:37
Summary
The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:digital_industrial_gateway_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4D9E061-4E5C-4390-916D-8AABE3523E16",
              "versionEndIncluding": "7.612",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:kepware_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A50F0395-983A-4261-9FE3-40762E5EC02F",
              "versionEndIncluding": "6.12",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:kepware_serverex:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7C3EDBB-FEB2-4BE7-A379-AF07F1BCD46D",
              "versionEndIncluding": "6.12",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_.net-sdk:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "63EBD473-C1FD-4B90-BEB9-38488F6EC8A5",
              "versionEndIncluding": "5.8.4.971",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_edge_c-sdk:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D82325D-070B-462B-B92F-34CC047D3340",
              "versionEndIncluding": "2.2.12.1052",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_edge_microserver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E860B82D-355A-4AB3-AA93-6B1D15A1B2D7",
              "versionEndIncluding": "5.4.10.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D01A814D-8F2B-4B88-A66B-F2A2C293A6AB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_edge:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C16730F8-C263-478B-B286-9831FFF5A409",
              "versionEndIncluding": "1.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5A51513-026A-43DA-9CB6-D5B68819CA47",
              "versionEndIncluding": "6.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nThe affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.\n\n"
    }
  ],
  "id": "CVE-2023-0755",
  "lastModified": "2024-11-21T07:37:45.493",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-02-23T22:15:11.427",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-129"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2023-0754

Vulnerability from fkie_nvd - Published: 2023-02-23 22:15 - Updated: 2024-11-21 07:37
Summary
The affected products are vulnerable to an integer overflow or wraparound, which could  allow an attacker to crash the server and remotely execute arbitrary code.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:digital_industrial_gateway_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4D9E061-4E5C-4390-916D-8AABE3523E16",
              "versionEndIncluding": "7.612",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:kepware_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A50F0395-983A-4261-9FE3-40762E5EC02F",
              "versionEndIncluding": "6.12",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:kepware_serverex:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7C3EDBB-FEB2-4BE7-A379-AF07F1BCD46D",
              "versionEndIncluding": "6.12",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_.net-sdk:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "63EBD473-C1FD-4B90-BEB9-38488F6EC8A5",
              "versionEndIncluding": "5.8.4.971",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_edge_c-sdk:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D82325D-070B-462B-B92F-34CC047D3340",
              "versionEndIncluding": "2.2.12.1052",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_edge_microserver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E860B82D-355A-4AB3-AA93-6B1D15A1B2D7",
              "versionEndIncluding": "5.4.10.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47A370A2-4847-4702-AC73-03A2B62C49C8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_edge:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C16730F8-C263-478B-B286-9831FFF5A409",
              "versionEndIncluding": "1.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5A51513-026A-43DA-9CB6-D5B68819CA47",
              "versionEndIncluding": "6.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nThe affected products are vulnerable to an integer\noverflow or wraparound, which could \u00a0allow an attacker to crash the server and remotely\nexecute arbitrary code.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n"
    }
  ],
  "id": "CVE-2023-0754",
  "lastModified": "2024-11-21T07:37:45.373",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-02-23T22:15:11.333",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-190"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2020-27265

Vulnerability from fkie_nvd - Published: 2021-01-14 00:15 - Updated: 2024-11-21 05:20
Severity ?
Summary
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code.
References

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:industrial_gateway_server:7.66:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5AEAC75-5E69-4C49-8D57-35401400C9D2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:industrial_gateway_server:7.68.804:*:*:*:*:*:*:*",
              "matchCriteriaId": "906B1D62-7656-457E-B528-B0407C9D0BA4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:kepware_kepserverex:6.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6994DBB6-BA65-4E47-B0E4-42310120FC04",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:kepware_kepserverex:6.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC1720A3-85F1-4A85-B226-1CCBB34FCAAC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:opc-aggregator:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8F46490-09F7-488A-B1EB-2286BFA0F882",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D01A814D-8F2B-4B88-A66B-F2A2C293A6AB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_server:6.8:*:*:*:*:*:*:*",
              "matchCriteriaId": "2DE510A4-1D91-447E-BF61-6CDFDFF82796",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_server:6.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F16FBD0-8841-4E42-8FE6-796F7B4E5C16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.6.504.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FFA2B21-E36C-41CE-B633-B831C6D42962",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.9.572.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "BACC2F09-9EC8-420A-B499-BF7CD737A473",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:softwaretoolbox:top_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "95B527BB-A27F-4080-8BBB-3FCA2408B7AE",
              "versionEndIncluding": "6.9",
              "versionStartIncluding": "6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code."
    },
    {
      "lang": "es",
      "value": "KEPServerEX: versiones v6.0 hasta v6.9, ThingWorx Kepware Server: versiones v6.8 y v6.9, ThingWorx Industrial Connectivity: Todas las versiones, OPC-Aggregator: Todas las versiones, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: versiones v7.68.804 y v7.66, Software Toolbox TOP Server: Todas las versiones 6.x, son vulnerables a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria.\u0026#xa0;Abrir un mensaje OPC UA espec\u00edficamente dise\u00f1ado podr\u00eda permitir a un atacante bloquear el servidor y ejecutar c\u00f3digo de remotamente"
    }
  ],
  "id": "CVE-2020-27265",
  "lastModified": "2024-11-21T05:20:58.083",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-14T00:15:13.417",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2020-27267

Vulnerability from fkie_nvd - Published: 2021-01-14 00:15 - Updated: 2024-11-21 05:20
Severity ?
Summary
KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
References

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:industrial_gateway_server:7.66:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5AEAC75-5E69-4C49-8D57-35401400C9D2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:industrial_gateway_server:7.68.804:*:*:*:*:*:*:*",
              "matchCriteriaId": "906B1D62-7656-457E-B528-B0407C9D0BA4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:kepware_kepserverex:6.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6994DBB6-BA65-4E47-B0E4-42310120FC04",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:kepware_kepserverex:6.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC1720A3-85F1-4A85-B226-1CCBB34FCAAC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:opc-aggregator:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8F46490-09F7-488A-B1EB-2286BFA0F882",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D01A814D-8F2B-4B88-A66B-F2A2C293A6AB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_server:6.8:*:*:*:*:*:*:*",
              "matchCriteriaId": "2DE510A4-1D91-447E-BF61-6CDFDFF82796",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_server:6.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F16FBD0-8841-4E42-8FE6-796F7B4E5C16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.6.504.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FFA2B21-E36C-41CE-B633-B831C6D42962",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.9.572.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "BACC2F09-9EC8-420A-B499-BF7CD737A473",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:softwaretoolbox:top_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "95B527BB-A27F-4080-8BBB-3FCA2408B7AE",
              "versionEndIncluding": "6.9",
              "versionStartIncluding": "6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
    },
    {
      "lang": "es",
      "value": "KEPServerEX versiones v6.0 hasta v6.9, ThingWorx Kepware Server versiones v6.8 y v6.9, ThingWorx Industrial Connectivity (todas las versiones), OPC-Aggregator (todas las versiones), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server versiones v7.68.804 y v7.66, y Software Toolbox TOP Server, todas las versiones 6.x, son vulnerables a un desbordamiento del b\u00fafer en la regi\u00f3n heap de la memoria.\u0026#xa0;Abrir un mensaje OPC UA espec\u00edficamente dise\u00f1ado podr\u00eda permitir a un atacante bloquear el servidor y potencialmente filtrar datos"
    }
  ],
  "id": "CVE-2020-27267",
  "lastModified": "2024-11-21T05:20:58.280",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.4,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-14T00:15:13.510",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-416"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2020-27263

Vulnerability from fkie_nvd - Published: 2021-01-14 00:15 - Updated: 2024-11-21 05:20
Severity ?
Summary
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
References

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:industrial_gateway_server:7.66:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5AEAC75-5E69-4C49-8D57-35401400C9D2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:industrial_gateway_server:7.68.804:*:*:*:*:*:*:*",
              "matchCriteriaId": "906B1D62-7656-457E-B528-B0407C9D0BA4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:kepware_kepserverex:6.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6994DBB6-BA65-4E47-B0E4-42310120FC04",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:kepware_kepserverex:6.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC1720A3-85F1-4A85-B226-1CCBB34FCAAC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:opc-aggregator:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8F46490-09F7-488A-B1EB-2286BFA0F882",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D01A814D-8F2B-4B88-A66B-F2A2C293A6AB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_server:6.8:*:*:*:*:*:*:*",
              "matchCriteriaId": "2DE510A4-1D91-447E-BF61-6CDFDFF82796",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ptc:thingworx_kepware_server:6.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F16FBD0-8841-4E42-8FE6-796F7B4E5C16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.6.504.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FFA2B21-E36C-41CE-B633-B831C6D42962",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.9.572.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "BACC2F09-9EC8-420A-B499-BF7CD737A473",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:softwaretoolbox:top_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "95B527BB-A27F-4080-8BBB-3FCA2408B7AE",
              "versionEndIncluding": "6.9",
              "versionStartIncluding": "6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
    },
    {
      "lang": "es",
      "value": "KEPServerEX: versiones v6.0 hasta v6.9, ThingWorx Kepware Server: versiones v6.8 y v6.9, ThingWorx Industrial Connectivity: Todas las versiones, OPC-Aggregator: Todas las versiones, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: versiones v7.68.804 y v7.66, Software Toolbox TOP Server: Todas las versiones 6.x son vulnerables a un desbordamiento de b\u00fafer en la regi\u00f3n heap de la memoria.\u0026#xa0;Abrir un mensaje OPC UA espec\u00edficamente dise\u00f1ado podr\u00eda permitir a un atacante bloquear el servidor y potencialmente filtrar datos"
    }
  ],
  "id": "CVE-2020-27263",
  "lastModified": "2024-11-21T05:20:57.887",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.4,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-14T00:15:13.353",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2023-5909 (GCVE-0-2023-5909)

Vulnerability from cvelistv5 – Published: 2023-11-30 22:05 – Updated: 2024-08-02 08:14
VLAI?
Title
Improper Validation of Certificate with Host Mismatch in PTC KEPServerEx
Summary
KEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.
CWE
  • CWE-297 - Improper Validation of Certificate with Host Mismatch
Assigner
References
Impacted products
Credits
Shawn Hoffman
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:14:24.693Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "KEPServerEX",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Server",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Industrial Connectivity",
          "vendor": "PTC",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "OPC-Aggregator",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "6.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Edge",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "1.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "KEPServer Enterprise",
          "vendor": "Rockwell Automation ",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Industrial Gateway Server",
          "vendor": "GE Gigital",
          "versions": [
            {
              "lessThanOrEqual": "7.614",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TOP Server",
          "vendor": "Software Toolbox",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Shawn Hoffman"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eKEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.\u003c/p\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n"
            }
          ],
          "value": "\n\n\n\n\n\n\n\n\nKEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.\n\n\n\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-297",
              "description": "CWE-297 Improper Validation of Certificate with Host Mismatch",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T22:05:59.595Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003ePTC has released and recommends users to update to the following versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003eKEPServerEX should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Server should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\u003c/li\u003e\u003cli\u003eOPC-Aggregator should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Edge: Upgrade to v1.8 or later\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eRefer to secure configuration guide \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide\"\u003ehere\u003c/a\u003e\u003c/p\u003e\u003cp\u003eIf additional questions remain, please contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log?\"\u003ePTC Technical Support\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information, see PTC\u0027s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS405439\"\u003eadvisory\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nPTC has released and recommends users to update to the following versions:\n\n  *  KEPServerEX should upgrade to v6.15 or later\n  *  ThingWorx Kepware Server should upgrade to v6.15 or later\n  *  ThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\n  *  OPC-Aggregator should upgrade to v6.15 or later\n  *  ThingWorx Kepware Edge: Upgrade to v1.8 or later\n\n\nRefer to secure configuration guide  here https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide \n\nIf additional questions remain, please contact  PTC Technical Support https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log \n\nFor more information, see PTC\u0027s  advisory https://www.ptc.com/en/support/article/CS405439 .\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper Validation of Certificate with Host Mismatch in PTC KEPServerEx",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-5909",
    "datePublished": "2023-11-30T22:05:59.595Z",
    "dateReserved": "2023-11-01T16:18:45.060Z",
    "dateUpdated": "2024-08-02T08:14:24.693Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-5908 (GCVE-0-2023-5908)

Vulnerability from cvelistv5 – Published: 2023-11-30 22:03 – Updated: 2024-08-02 08:14
VLAI?
Title
Heap Based Buffer Overflow in PTC KEPServerEx
Summary
KEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.
CWE
  • CWE-122 - Heap-Based Buffer Overflow
Assigner
References
Impacted products
Credits
Shawn Hoffman
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:14:24.586Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "KEPServerEX",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Server",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Industrial Connectivity",
          "vendor": "PTC",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "OPC-Aggregator",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "6.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Edge",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "1.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "KEPServer Enterprise",
          "vendor": "Rockwell Automation ",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Industrial Gateway Server",
          "vendor": "GE Gigital",
          "versions": [
            {
              "lessThanOrEqual": "7.614",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TOP Server",
          "vendor": "Software Toolbox",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Shawn Hoffman"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eKEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.\u003c/p\u003e\u003cbr\u003e\n\n"
            }
          ],
          "value": "\n\n\n\n\nKEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122 Heap-Based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T22:03:58.098Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003ePTC has released and recommends users to update to the following versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003eKEPServerEX should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Server should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\u003c/li\u003e\u003cli\u003eOPC-Aggregator should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Edge: Upgrade to v1.8 or later\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eRefer to secure configuration guide \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide\"\u003ehere\u003c/a\u003e\u003c/p\u003e\u003cp\u003eIf additional questions remain, please contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log?\"\u003ePTC Technical Support\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information, see PTC\u0027s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS405439\"\u003eadvisory\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nPTC has released and recommends users to update to the following versions:\n\n  *  KEPServerEX should upgrade to v6.15 or later\n  *  ThingWorx Kepware Server should upgrade to v6.15 or later\n  *  ThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\n  *  OPC-Aggregator should upgrade to v6.15 or later\n  *  ThingWorx Kepware Edge: Upgrade to v1.8 or later\n\n\nRefer to secure configuration guide  here https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide \n\nIf additional questions remain, please contact  PTC Technical Support https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log \n\nFor more information, see PTC\u0027s  advisory https://www.ptc.com/en/support/article/CS405439 .\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Heap Based Buffer Overflow in PTC KEPServerEx",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-5908",
    "datePublished": "2023-11-30T22:03:58.098Z",
    "dateReserved": "2023-11-01T16:18:42.353Z",
    "dateUpdated": "2024-08-02T08:14:24.586Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2825 (GCVE-0-2022-2825)

Vulnerability from cvelistv5 – Published: 2023-03-29 00:00 – Updated: 2025-02-18 16:16
VLAI?
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
zdi
Impacted products
Vendor Product Version
Kepware KEPServerEX Affected: 6.11.718.0
Create a notification for this product.
Credits
Vera Mens, Uri Katz, Sharon Brizinov of Claroty Research
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:58.837Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1455/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-2825",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-18T15:48:06.564232Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-18T16:16:11.214Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "KEPServerEX",
          "vendor": "Kepware",
          "versions": [
            {
              "status": "affected",
              "version": "6.11.718.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Vera Mens, Uri Katz, Sharon Brizinov of Claroty Research"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-20T00:00:00.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1455/"
        },
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2022-2825",
    "datePublished": "2023-03-29T00:00:00.000Z",
    "dateReserved": "2022-08-15T00:00:00.000Z",
    "dateUpdated": "2025-02-18T16:16:11.214Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2848 (GCVE-0-2022-2848)

Vulnerability from cvelistv5 – Published: 2023-03-29 00:00 – Updated: 2025-02-18 16:42
VLAI?
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16486.
CWE
  • CWE-122 - Heap-based Buffer Overflow
Assigner
zdi
Impacted products
Vendor Product Version
Kepware KEPServerEX Affected: 6.11.718.0
Create a notification for this product.
Credits
Vera Mens, Uri Katz, Sharon Brizinov of Claroty Research
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:58.526Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1454/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2848",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-18T15:45:30.371828Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-18T16:42:21.939Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "KEPServerEX",
          "vendor": "Kepware",
          "versions": [
            {
              "status": "affected",
              "version": "6.11.718.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Vera Mens, Uri Katz, Sharon Brizinov of Claroty Research"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16486."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-20T00:00:00.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
        },
        {
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1454/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2022-2848",
    "datePublished": "2023-03-29T00:00:00.000Z",
    "dateReserved": "2022-08-16T00:00:00.000Z",
    "dateUpdated": "2025-02-18T16:42:21.939Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-0754 (GCVE-0-2023-0754)

Vulnerability from cvelistv5 – Published: 2023-02-23 21:27 – Updated: 2025-01-16 21:55
VLAI?
Summary
The affected products are vulnerable to an integer overflow or wraparound, which could  allow an attacker to crash the server and remotely execute arbitrary code.
CWE
  • CWE-190 - Integer Overflow or Wraparound
Assigner
Credits
Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T05:24:34.053Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-0754",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:59:05.493845Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:55:46.607Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Edge C-SDK",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v2.2.12.1052 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": ".NET-SDK",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThanOrEqual": "v5.8.4.971 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Edge MicroServer (EMS)",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v5.4.10.0 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Kepware KEPServerEX",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v6.12 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Server ",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v6.12 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Industrial Connectivity",
          "vendor": "PTC",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Edge",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v1.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "KEPServer Enterprise ",
          "vendor": "Rockwell Automation ",
          "versions": [
            {
              "lessThanOrEqual": "v6.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Digital Industrial Gateway Server ",
          "vendor": "General Electric ",
          "versions": [
            {
              "lessThanOrEqual": "v7.612",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003c/p\u003e\u003cp\u003eThe affected products are vulnerable to an integer\noverflow or wraparound, which could \u0026nbsp;allow an attacker to crash the server and remotely\nexecute arbitrary code.\u003c/p\u003e\n\n\n\n\n\n\u003cp\u003e\u003c/p\u003e\n\n\n\n\n\n"
            }
          ],
          "value": "\nThe affected products are vulnerable to an integer\noverflow or wraparound, which could \u00a0allow an attacker to crash the server and remotely\nexecute arbitrary code.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "CWE-190 Integer Overflow or Wraparound",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-23T21:27:09.964Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003ePTC has released the following resolutions:\u003c/p\u003e\n\n\u003cp\u003eUpdate the impacted product to the latest version:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge C-SDK: 3.0.0 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\n.NET-SDK: v5.8.5 or later.\u003c/p\u003e\n\n\u003cp\u003eFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is \u003cb\u003enot\u003c/b\u003e enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nKepware KEPServerEX: v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Edge: v1.6 or later.\u003c/p\u003e\n\n\u003cp\u003eThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\u003c/p\u003e\n\n\u003cp\u003eFor\nmore information see PTC\u2019s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS385715\"\u003eCustomer Support Article\n\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nKepware KEPServerEX: v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.\n\n\n\n\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-0754",
    "datePublished": "2023-02-23T21:27:09.964Z",
    "dateReserved": "2023-02-08T20:15:58.394Z",
    "dateUpdated": "2025-01-16T21:55:46.607Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-0755 (GCVE-0-2023-0755)

Vulnerability from cvelistv5 – Published: 2023-02-23 21:23 – Updated: 2025-01-16 21:55
VLAI?
Summary
The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.
CWE
  • CWE-129 - Improper Validation of Array Index
Assigner
Credits
Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T05:24:34.155Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-0755",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:59:08.379075Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:55:52.537Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Edge C-SDK",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v2.2.12.1052 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": ".NET-SDK",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThanOrEqual": "v5.8.4.971 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Edge MicroServer (EMS)",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v5.4.10.0 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Kepware KEPServerEX",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v6.12 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Server ",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v6.12 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Industrial Connectivity",
          "vendor": "PTC",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Edge",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v1.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "KEPServer Enterprise ",
          "vendor": "Rockwell Automation ",
          "versions": [
            {
              "lessThanOrEqual": "v6.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Digital Industrial Gateway Server ",
          "vendor": "General Electric ",
          "versions": [
            {
              "lessThanOrEqual": "v7.612",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2023-02-23T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nThe affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-129",
              "description": "CWE-129 Improper Validation of Array Index",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-23T21:23:19.210Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003ePTC has released the following resolutions:\u003c/p\u003e\n\n\u003cp\u003eUpdate the impacted product to the latest version:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge C-SDK: 3.0.0 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\n.NET-SDK: v5.8.5 or later.\u003c/p\u003e\n\n\u003cp\u003eFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is \u003cb\u003enot\u003c/b\u003e enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nKepware KEPServerEX: v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Edge: v1.6 or later.\u003c/p\u003e\n\n\u003cp\u003eThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\u003c/p\u003e\n\n\u003cp\u003eFor\nmore information see PTC\u2019s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS385715\"\u003eCustomer Support Article\n\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nKepware KEPServerEX: v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.\n\n\n\n\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-0755",
    "datePublished": "2023-02-23T21:23:19.210Z",
    "dateReserved": "2023-02-08T20:21:34.258Z",
    "dateUpdated": "2025-01-16T21:55:52.537Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-27265 (GCVE-0-2020-27265)

Vulnerability from cvelistv5 – Published: 2021-01-13 23:33 – Updated: 2024-08-04 16:11
VLAI?
Summary
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code.
Severity ?
No CVSS data available.
CWE
  • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
Assigner
References
Impacted products
Vendor Product Version
n/a PTC Kepware KEPServerEX; ThingWorx Industrial Connectivity; OPC-Aggregator; Rockwell Automation KEPServer Enterprise; GE Digital Industrial Gateway Server; Software Toolbox TOP Server Affected: v6.0 to v6.9
Affected: v6.8 and v6.9
Affected: All versions
Affected: v7.68.804, v7.66
Affected: All 6.x versions
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:11:36.330Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PTC Kepware KEPServerEX;  ThingWorx Industrial Connectivity; OPC-Aggregator; Rockwell Automation KEPServer Enterprise; GE Digital Industrial Gateway Server; Software Toolbox TOP Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "v6.0 to v6.9"
            },
            {
              "status": "affected",
              "version": "v6.8 and v6.9"
            },
            {
              "status": "affected",
              "version": "All versions"
            },
            {
              "status": "affected",
              "version": "v7.68.804, v7.66"
            },
            {
              "status": "affected",
              "version": "All 6.x versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-13T23:33:45",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-27265",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PTC Kepware KEPServerEX;  ThingWorx Industrial Connectivity; OPC-Aggregator; Rockwell Automation KEPServer Enterprise; GE Digital Industrial Gateway Server; Software Toolbox TOP Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v6.0 to v6.9"
                          },
                          {
                            "version_value": "v6.8 and v6.9"
                          },
                          {
                            "version_value": "All versions"
                          },
                          {
                            "version_value": "All versions"
                          },
                          {
                            "version_value": "All versions"
                          },
                          {
                            "version_value": "v7.68.804, v7.66"
                          },
                          {
                            "version_value": "All 6.x versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-27265",
    "datePublished": "2021-01-13T23:33:45",
    "dateReserved": "2020-10-19T00:00:00",
    "dateUpdated": "2024-08-04T16:11:36.330Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-27263 (GCVE-0-2020-27263)

Vulnerability from cvelistv5 – Published: 2021-01-13 23:30 – Updated: 2024-08-04 16:11
VLAI?
Summary
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
Severity ?
No CVSS data available.
CWE
  • CWE-122 - HEAP-BASED BUFFER OVERFLOW CWE-122
Assigner
References
Impacted products
Vendor Product Version
n/a PTC Kepware KEPServerEX Affected: v6.0 to v6.9
    n/a ThingWorx Kepware Server Affected: v6.8 and v6.9
    n/a ThingWorx Industrial Connectivity Affected: All versions
    n/a OPC-Aggregator Affected: All versions
    n/a Rockwell Automation KEPServer Enterprise Affected: All versions
    n/a GE Digital Industrial Gateway Server Affected: v7.68.804
Affected: v7.66
    n/a Software Toolbox TOP Server Affected: All 6.x versions
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:11:36.407Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PTC Kepware KEPServerEX",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "v6.0 to v6.9"
            }
          ]
        },
        {
          "product": "ThingWorx Kepware Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "v6.8 and v6.9"
            }
          ]
        },
        {
          "product": "ThingWorx Industrial Connectivity",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "OPC-Aggregator",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Rockwell Automation KEPServer Enterprise",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "GE Digital Industrial Gateway Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "v7.68.804"
            },
            {
              "status": "affected",
              "version": "v7.66"
            }
          ]
        },
        {
          "product": "Software Toolbox TOP Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All 6.x versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-13T23:30:08",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-27263",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PTC Kepware KEPServerEX",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v6.0 to v6.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ThingWorx Kepware Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v6.8 and v6.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ThingWorx Industrial Connectivity",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OPC-Aggregator",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Rockwell Automation KEPServer Enterprise",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GE Digital Industrial Gateway Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v7.68.804"
                          },
                          {
                            "version_value": "v7.66"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Software Toolbox TOP Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All 6.x versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-27263",
    "datePublished": "2021-01-13T23:30:08",
    "dateReserved": "2020-10-19T00:00:00",
    "dateUpdated": "2024-08-04T16:11:36.407Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-27267 (GCVE-0-2020-27267)

Vulnerability from cvelistv5 – Published: 2021-01-13 23:25 – Updated: 2024-08-04 16:11
VLAI?
Summary
KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a PTC Kepware KEPServerEX Affected: v6.0 to v6.9
    n/a ThingWorx Kepware Server Affected: v6.8 and v6.9
    n/a ThingWorx Industrial Connectivity Affected: All versions
    n/a OPC-Aggregator Affected: All versions
    n/a Rockwell Automation KEPServer Enterprise Affected: All versions
    n/a GE Digital Industrial Gateway Server Affected: v7.68.804
Affected: v7.66
    n/a Software Toolbox TOP Server Affected: All 6.x versions
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:11:36.412Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PTC Kepware KEPServerEX",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "v6.0 to v6.9"
            }
          ]
        },
        {
          "product": "ThingWorx Kepware Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "v6.8 and v6.9"
            }
          ]
        },
        {
          "product": "ThingWorx Industrial Connectivity",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "OPC-Aggregator",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Rockwell Automation KEPServer Enterprise",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "GE Digital Industrial Gateway Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "v7.68.804"
            },
            {
              "status": "affected",
              "version": "v7.66"
            }
          ]
        },
        {
          "product": "Software Toolbox TOP Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All 6.x versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "USE AFTER FREE CWE-416",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-13T23:25:07",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-27267",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PTC Kepware KEPServerEX",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v6.0 to v6.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ThingWorx Kepware Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v6.8 and v6.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ThingWorx Industrial Connectivity",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OPC-Aggregator",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Rockwell Automation KEPServer Enterprise",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GE Digital Industrial Gateway Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v7.68.804"
                          },
                          {
                            "version_value": "v7.66"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Software Toolbox TOP Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All 6.x versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "USE AFTER FREE CWE-416"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-27267",
    "datePublished": "2021-01-13T23:25:07",
    "dateReserved": "2020-10-19T00:00:00",
    "dateUpdated": "2024-08-04T16:11:36.412Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-5909 (GCVE-0-2023-5909)

Vulnerability from nvd – Published: 2023-11-30 22:05 – Updated: 2024-08-02 08:14
VLAI?
Title
Improper Validation of Certificate with Host Mismatch in PTC KEPServerEx
Summary
KEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.
CWE
  • CWE-297 - Improper Validation of Certificate with Host Mismatch
Assigner
References
Impacted products
Credits
Shawn Hoffman
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:14:24.693Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "KEPServerEX",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Server",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Industrial Connectivity",
          "vendor": "PTC",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "OPC-Aggregator",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "6.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Edge",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "1.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "KEPServer Enterprise",
          "vendor": "Rockwell Automation ",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Industrial Gateway Server",
          "vendor": "GE Gigital",
          "versions": [
            {
              "lessThanOrEqual": "7.614",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TOP Server",
          "vendor": "Software Toolbox",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Shawn Hoffman"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eKEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.\u003c/p\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n"
            }
          ],
          "value": "\n\n\n\n\n\n\n\n\nKEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.\n\n\n\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-297",
              "description": "CWE-297 Improper Validation of Certificate with Host Mismatch",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T22:05:59.595Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003ePTC has released and recommends users to update to the following versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003eKEPServerEX should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Server should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\u003c/li\u003e\u003cli\u003eOPC-Aggregator should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Edge: Upgrade to v1.8 or later\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eRefer to secure configuration guide \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide\"\u003ehere\u003c/a\u003e\u003c/p\u003e\u003cp\u003eIf additional questions remain, please contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log?\"\u003ePTC Technical Support\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information, see PTC\u0027s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS405439\"\u003eadvisory\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nPTC has released and recommends users to update to the following versions:\n\n  *  KEPServerEX should upgrade to v6.15 or later\n  *  ThingWorx Kepware Server should upgrade to v6.15 or later\n  *  ThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\n  *  OPC-Aggregator should upgrade to v6.15 or later\n  *  ThingWorx Kepware Edge: Upgrade to v1.8 or later\n\n\nRefer to secure configuration guide  here https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide \n\nIf additional questions remain, please contact  PTC Technical Support https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log \n\nFor more information, see PTC\u0027s  advisory https://www.ptc.com/en/support/article/CS405439 .\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper Validation of Certificate with Host Mismatch in PTC KEPServerEx",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-5909",
    "datePublished": "2023-11-30T22:05:59.595Z",
    "dateReserved": "2023-11-01T16:18:45.060Z",
    "dateUpdated": "2024-08-02T08:14:24.693Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-5908 (GCVE-0-2023-5908)

Vulnerability from nvd – Published: 2023-11-30 22:03 – Updated: 2024-08-02 08:14
VLAI?
Title
Heap Based Buffer Overflow in PTC KEPServerEx
Summary
KEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.
CWE
  • CWE-122 - Heap-Based Buffer Overflow
Assigner
References
Impacted products
Credits
Shawn Hoffman
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:14:24.586Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "KEPServerEX",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Server",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Industrial Connectivity",
          "vendor": "PTC",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "OPC-Aggregator",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "6.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Edge",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "1.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "KEPServer Enterprise",
          "vendor": "Rockwell Automation ",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Industrial Gateway Server",
          "vendor": "GE Gigital",
          "versions": [
            {
              "lessThanOrEqual": "7.614",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TOP Server",
          "vendor": "Software Toolbox",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Shawn Hoffman"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eKEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.\u003c/p\u003e\u003cbr\u003e\n\n"
            }
          ],
          "value": "\n\n\n\n\nKEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122 Heap-Based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T22:03:58.098Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003ePTC has released and recommends users to update to the following versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003eKEPServerEX should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Server should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\u003c/li\u003e\u003cli\u003eOPC-Aggregator should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Edge: Upgrade to v1.8 or later\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eRefer to secure configuration guide \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide\"\u003ehere\u003c/a\u003e\u003c/p\u003e\u003cp\u003eIf additional questions remain, please contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log?\"\u003ePTC Technical Support\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information, see PTC\u0027s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS405439\"\u003eadvisory\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nPTC has released and recommends users to update to the following versions:\n\n  *  KEPServerEX should upgrade to v6.15 or later\n  *  ThingWorx Kepware Server should upgrade to v6.15 or later\n  *  ThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\n  *  OPC-Aggregator should upgrade to v6.15 or later\n  *  ThingWorx Kepware Edge: Upgrade to v1.8 or later\n\n\nRefer to secure configuration guide  here https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide \n\nIf additional questions remain, please contact  PTC Technical Support https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log \n\nFor more information, see PTC\u0027s  advisory https://www.ptc.com/en/support/article/CS405439 .\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Heap Based Buffer Overflow in PTC KEPServerEx",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-5908",
    "datePublished": "2023-11-30T22:03:58.098Z",
    "dateReserved": "2023-11-01T16:18:42.353Z",
    "dateUpdated": "2024-08-02T08:14:24.586Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2825 (GCVE-0-2022-2825)

Vulnerability from nvd – Published: 2023-03-29 00:00 – Updated: 2025-02-18 16:16
VLAI?
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
zdi
Impacted products
Vendor Product Version
Kepware KEPServerEX Affected: 6.11.718.0
Create a notification for this product.
Credits
Vera Mens, Uri Katz, Sharon Brizinov of Claroty Research
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:58.837Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1455/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-2825",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-18T15:48:06.564232Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-18T16:16:11.214Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "KEPServerEX",
          "vendor": "Kepware",
          "versions": [
            {
              "status": "affected",
              "version": "6.11.718.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Vera Mens, Uri Katz, Sharon Brizinov of Claroty Research"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-20T00:00:00.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1455/"
        },
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2022-2825",
    "datePublished": "2023-03-29T00:00:00.000Z",
    "dateReserved": "2022-08-15T00:00:00.000Z",
    "dateUpdated": "2025-02-18T16:16:11.214Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2848 (GCVE-0-2022-2848)

Vulnerability from nvd – Published: 2023-03-29 00:00 – Updated: 2025-02-18 16:42
VLAI?
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16486.
CWE
  • CWE-122 - Heap-based Buffer Overflow
Assigner
zdi
Impacted products
Vendor Product Version
Kepware KEPServerEX Affected: 6.11.718.0
Create a notification for this product.
Credits
Vera Mens, Uri Katz, Sharon Brizinov of Claroty Research
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:58.526Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1454/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2848",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-18T15:45:30.371828Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-18T16:42:21.939Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "KEPServerEX",
          "vendor": "Kepware",
          "versions": [
            {
              "status": "affected",
              "version": "6.11.718.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Vera Mens, Uri Katz, Sharon Brizinov of Claroty Research"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16486."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-20T00:00:00.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-10"
        },
        {
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1454/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2022-2848",
    "datePublished": "2023-03-29T00:00:00.000Z",
    "dateReserved": "2022-08-16T00:00:00.000Z",
    "dateUpdated": "2025-02-18T16:42:21.939Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-0754 (GCVE-0-2023-0754)

Vulnerability from nvd – Published: 2023-02-23 21:27 – Updated: 2025-01-16 21:55
VLAI?
Summary
The affected products are vulnerable to an integer overflow or wraparound, which could  allow an attacker to crash the server and remotely execute arbitrary code.
CWE
  • CWE-190 - Integer Overflow or Wraparound
Assigner
Credits
Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T05:24:34.053Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-0754",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:59:05.493845Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:55:46.607Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Edge C-SDK",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v2.2.12.1052 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": ".NET-SDK",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThanOrEqual": "v5.8.4.971 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Edge MicroServer (EMS)",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v5.4.10.0 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Kepware KEPServerEX",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v6.12 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Server ",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v6.12 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Industrial Connectivity",
          "vendor": "PTC",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Edge",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v1.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "KEPServer Enterprise ",
          "vendor": "Rockwell Automation ",
          "versions": [
            {
              "lessThanOrEqual": "v6.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Digital Industrial Gateway Server ",
          "vendor": "General Electric ",
          "versions": [
            {
              "lessThanOrEqual": "v7.612",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003c/p\u003e\u003cp\u003eThe affected products are vulnerable to an integer\noverflow or wraparound, which could \u0026nbsp;allow an attacker to crash the server and remotely\nexecute arbitrary code.\u003c/p\u003e\n\n\n\n\n\n\u003cp\u003e\u003c/p\u003e\n\n\n\n\n\n"
            }
          ],
          "value": "\nThe affected products are vulnerable to an integer\noverflow or wraparound, which could \u00a0allow an attacker to crash the server and remotely\nexecute arbitrary code.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "CWE-190 Integer Overflow or Wraparound",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-23T21:27:09.964Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003ePTC has released the following resolutions:\u003c/p\u003e\n\n\u003cp\u003eUpdate the impacted product to the latest version:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge C-SDK: 3.0.0 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\n.NET-SDK: v5.8.5 or later.\u003c/p\u003e\n\n\u003cp\u003eFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is \u003cb\u003enot\u003c/b\u003e enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nKepware KEPServerEX: v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Edge: v1.6 or later.\u003c/p\u003e\n\n\u003cp\u003eThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\u003c/p\u003e\n\n\u003cp\u003eFor\nmore information see PTC\u2019s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS385715\"\u003eCustomer Support Article\n\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nKepware KEPServerEX: v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.\n\n\n\n\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-0754",
    "datePublished": "2023-02-23T21:27:09.964Z",
    "dateReserved": "2023-02-08T20:15:58.394Z",
    "dateUpdated": "2025-01-16T21:55:46.607Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-0755 (GCVE-0-2023-0755)

Vulnerability from nvd – Published: 2023-02-23 21:23 – Updated: 2025-01-16 21:55
VLAI?
Summary
The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.
CWE
  • CWE-129 - Improper Validation of Array Index
Assigner
Credits
Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T05:24:34.155Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-0755",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:59:08.379075Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:55:52.537Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Edge C-SDK",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v2.2.12.1052 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": ".NET-SDK",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThanOrEqual": "v5.8.4.971 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Edge MicroServer (EMS)",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v5.4.10.0 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Kepware KEPServerEX",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v6.12 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Server ",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v6.12 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Industrial Connectivity",
          "vendor": "PTC",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ThingWorx Kepware Edge",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "v1.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "KEPServer Enterprise ",
          "vendor": "Rockwell Automation ",
          "versions": [
            {
              "lessThanOrEqual": "v6.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Digital Industrial Gateway Server ",
          "vendor": "General Electric ",
          "versions": [
            {
              "lessThanOrEqual": "v7.612",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2023-02-23T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nThe affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-129",
              "description": "CWE-129 Improper Validation of Array Index",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-23T21:23:19.210Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003ePTC has released the following resolutions:\u003c/p\u003e\n\n\u003cp\u003eUpdate the impacted product to the latest version:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge C-SDK: 3.0.0 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\n.NET-SDK: v5.8.5 or later.\u003c/p\u003e\n\n\u003cp\u003eFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is \u003cb\u003enot\u003c/b\u003e enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nKepware KEPServerEX: v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Edge: v1.6 or later.\u003c/p\u003e\n\n\u003cp\u003eThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\u003c/p\u003e\n\n\u003cp\u003eFor\nmore information see PTC\u2019s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS385715\"\u003eCustomer Support Article\n\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nKepware KEPServerEX: v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.\n\n\n\n\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-0755",
    "datePublished": "2023-02-23T21:23:19.210Z",
    "dateReserved": "2023-02-08T20:21:34.258Z",
    "dateUpdated": "2025-01-16T21:55:52.537Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-27265 (GCVE-0-2020-27265)

Vulnerability from nvd – Published: 2021-01-13 23:33 – Updated: 2024-08-04 16:11
VLAI?
Summary
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code.
Severity ?
No CVSS data available.
CWE
  • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
Assigner
References
Impacted products
Vendor Product Version
n/a PTC Kepware KEPServerEX; ThingWorx Industrial Connectivity; OPC-Aggregator; Rockwell Automation KEPServer Enterprise; GE Digital Industrial Gateway Server; Software Toolbox TOP Server Affected: v6.0 to v6.9
Affected: v6.8 and v6.9
Affected: All versions
Affected: v7.68.804, v7.66
Affected: All 6.x versions
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:11:36.330Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PTC Kepware KEPServerEX;  ThingWorx Industrial Connectivity; OPC-Aggregator; Rockwell Automation KEPServer Enterprise; GE Digital Industrial Gateway Server; Software Toolbox TOP Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "v6.0 to v6.9"
            },
            {
              "status": "affected",
              "version": "v6.8 and v6.9"
            },
            {
              "status": "affected",
              "version": "All versions"
            },
            {
              "status": "affected",
              "version": "v7.68.804, v7.66"
            },
            {
              "status": "affected",
              "version": "All 6.x versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-13T23:33:45",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-27265",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PTC Kepware KEPServerEX;  ThingWorx Industrial Connectivity; OPC-Aggregator; Rockwell Automation KEPServer Enterprise; GE Digital Industrial Gateway Server; Software Toolbox TOP Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v6.0 to v6.9"
                          },
                          {
                            "version_value": "v6.8 and v6.9"
                          },
                          {
                            "version_value": "All versions"
                          },
                          {
                            "version_value": "All versions"
                          },
                          {
                            "version_value": "All versions"
                          },
                          {
                            "version_value": "v7.68.804, v7.66"
                          },
                          {
                            "version_value": "All 6.x versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-27265",
    "datePublished": "2021-01-13T23:33:45",
    "dateReserved": "2020-10-19T00:00:00",
    "dateUpdated": "2024-08-04T16:11:36.330Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-27263 (GCVE-0-2020-27263)

Vulnerability from nvd – Published: 2021-01-13 23:30 – Updated: 2024-08-04 16:11
VLAI?
Summary
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
Severity ?
No CVSS data available.
CWE
  • CWE-122 - HEAP-BASED BUFFER OVERFLOW CWE-122
Assigner
References
Impacted products
Vendor Product Version
n/a PTC Kepware KEPServerEX Affected: v6.0 to v6.9
    n/a ThingWorx Kepware Server Affected: v6.8 and v6.9
    n/a ThingWorx Industrial Connectivity Affected: All versions
    n/a OPC-Aggregator Affected: All versions
    n/a Rockwell Automation KEPServer Enterprise Affected: All versions
    n/a GE Digital Industrial Gateway Server Affected: v7.68.804
Affected: v7.66
    n/a Software Toolbox TOP Server Affected: All 6.x versions
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:11:36.407Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PTC Kepware KEPServerEX",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "v6.0 to v6.9"
            }
          ]
        },
        {
          "product": "ThingWorx Kepware Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "v6.8 and v6.9"
            }
          ]
        },
        {
          "product": "ThingWorx Industrial Connectivity",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "OPC-Aggregator",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Rockwell Automation KEPServer Enterprise",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "GE Digital Industrial Gateway Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "v7.68.804"
            },
            {
              "status": "affected",
              "version": "v7.66"
            }
          ]
        },
        {
          "product": "Software Toolbox TOP Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All 6.x versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-13T23:30:08",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-27263",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PTC Kepware KEPServerEX",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v6.0 to v6.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ThingWorx Kepware Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v6.8 and v6.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ThingWorx Industrial Connectivity",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OPC-Aggregator",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Rockwell Automation KEPServer Enterprise",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GE Digital Industrial Gateway Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v7.68.804"
                          },
                          {
                            "version_value": "v7.66"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Software Toolbox TOP Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All 6.x versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-27263",
    "datePublished": "2021-01-13T23:30:08",
    "dateReserved": "2020-10-19T00:00:00",
    "dateUpdated": "2024-08-04T16:11:36.407Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-27267 (GCVE-0-2020-27267)

Vulnerability from nvd – Published: 2021-01-13 23:25 – Updated: 2024-08-04 16:11
VLAI?
Summary
KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a PTC Kepware KEPServerEX Affected: v6.0 to v6.9
    n/a ThingWorx Kepware Server Affected: v6.8 and v6.9
    n/a ThingWorx Industrial Connectivity Affected: All versions
    n/a OPC-Aggregator Affected: All versions
    n/a Rockwell Automation KEPServer Enterprise Affected: All versions
    n/a GE Digital Industrial Gateway Server Affected: v7.68.804
Affected: v7.66
    n/a Software Toolbox TOP Server Affected: All 6.x versions
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:11:36.412Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PTC Kepware KEPServerEX",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "v6.0 to v6.9"
            }
          ]
        },
        {
          "product": "ThingWorx Kepware Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "v6.8 and v6.9"
            }
          ]
        },
        {
          "product": "ThingWorx Industrial Connectivity",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "OPC-Aggregator",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Rockwell Automation KEPServer Enterprise",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "GE Digital Industrial Gateway Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "v7.68.804"
            },
            {
              "status": "affected",
              "version": "v7.66"
            }
          ]
        },
        {
          "product": "Software Toolbox TOP Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All 6.x versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "USE AFTER FREE CWE-416",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-13T23:25:07",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-27267",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PTC Kepware KEPServerEX",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v6.0 to v6.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ThingWorx Kepware Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v6.8 and v6.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ThingWorx Industrial Connectivity",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OPC-Aggregator",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Rockwell Automation KEPServer Enterprise",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GE Digital Industrial Gateway Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v7.68.804"
                          },
                          {
                            "version_value": "v7.66"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Software Toolbox TOP Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All 6.x versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "USE AFTER FREE CWE-416"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-27267",
    "datePublished": "2021-01-13T23:25:07",
    "dateReserved": "2020-10-19T00:00:00",
    "dateUpdated": "2024-08-04T16:11:36.412Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}