    CVE-2026-40852 (GCVE-0-2026-40852)

    Vulnerability from nvd – Published: 2026-05-27 08:06 – Updated: 2026-05-27 11:54
    VLAI
    Title
    Command injection via malicious configuration
    Summary
    A highly authenticated attacker can alter the config generator injecting a payload into future created configurations. The device is not correctly checking this configuration value before passing it to an system execute leading to code execution. This can result in a total loss of confidentiality, integrity and availability.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Credits
    Moritz Abrell from SySS GmbH Christian Zäske from SySS GmbH
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-40852",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-27T11:44:33.329985Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-27T11:54:17.274Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET/mbNET.rokey",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "8.4.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "3.0.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET/mbNET.rokey",
              "vendor": "MB connect line",
              "versions": [
                {
                  "status": "affected",
                  "version": "8.4.4"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0.2"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX200/250",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "8.4.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "3.0.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX200/250",
              "vendor": "Helmholz",
              "versions": [
                {
                  "status": "affected",
                  "version": "8.4.4"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:mb_connect_line:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "8.4.4",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "3.0.2",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:mb_connect_line:mbnet:8.4.4:*:*:*:*:*:*:*",
                      "versionStartIncluding": "8.4.4",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:mb_connect_line:mbnet.mini:3.0.2:*:*:*:*:*:*:*",
                      "versionStartIncluding": "3.0.2",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:helmholz:rex200_250:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "8.4.4",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "3.0.2",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:helmholz:rex200_250:8.4.4:*:*:*:*:*:*:*",
                      "versionStartIncluding": "8.4.4",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:helmholz:rex100:3.0.2:*:*:*:*:*:*:*",
                      "versionStartIncluding": "3.0.2",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Moritz Abrell from SySS GmbH"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Christian Z\u00e4ske from SySS GmbH"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA highly authenticated attacker can alter the config generator injecting a payload into future created configurations. The device is not correctly checking this configuration value before passing it to an system execute leading to code execution. This can result in a total loss of confidentiality, integrity and availability.\u003c/p\u003e"
                }
              ],
              "value": "A highly authenticated attacker can alter the config generator injecting a payload into future created configurations. The device is not correctly checking this configuration value before passing it to an system execute leading to code execution. This can result in a total loss of confidentiality, integrity and availability."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-27T08:06:36.875Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-054/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-054",
            "defect": [
              "CERT@VDE#642070"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Command injection via malicious configuration",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-40852",
        "datePublished": "2026-05-27T08:06:36.875Z",
        "dateReserved": "2026-04-15T09:33:02.614Z",
        "dateUpdated": "2026-05-27T11:54:17.274Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-40851 (GCVE-0-2026-40851)

    Vulnerability from nvd – Published: 2026-05-27 08:06 – Updated: 2026-05-27 11:54
    VLAI
    Title
    Command injection via USB
    Summary
    A local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-1287 - Improper Validation of Specified Type of Input
    Assigner
    References
    Credits
    Moritz Abrell from SySS GmbH Christian Zäske from SySS GmbH
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-40851",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-27T11:44:44.253548Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-27T11:54:33.819Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET/mbNET.rokey",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "8.4.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "3.0.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET/mbNET.rokey",
              "vendor": "MB connect line",
              "versions": [
                {
                  "status": "affected",
                  "version": "8.4.4"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0.2"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX200/250",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "8.4.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "3.0.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX200/250",
              "vendor": "Helmholz",
              "versions": [
                {
                  "status": "affected",
                  "version": "8.4.4"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:mb_connect_line:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "8.4.4",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "3.0.2",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:mb_connect_line:mbnet:8.4.4:*:*:*:*:*:*:*",
                      "versionStartIncluding": "8.4.4",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:mb_connect_line:mbnet.mini:3.0.2:*:*:*:*:*:*:*",
                      "versionStartIncluding": "3.0.2",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:helmholz:rex200_250:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "8.4.4",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "3.0.2",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:helmholz:rex200_250:8.4.4:*:*:*:*:*:*:*",
                      "versionStartIncluding": "8.4.4",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:helmholz:rex100:3.0.2:*:*:*:*:*:*:*",
                      "versionStartIncluding": "3.0.2",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Moritz Abrell from SySS GmbH"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Christian Z\u00e4ske from SySS GmbH"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability.\u003c/p\u003e"
                }
              ],
              "value": "A local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1287",
                  "description": "CWE-1287 Improper Validation of Specified Type of Input",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-27T08:06:21.815Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-054/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-054",
            "defect": [
              "CERT@VDE#642070"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Command injection via USB",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-40851",
        "datePublished": "2026-05-27T08:06:21.815Z",
        "dateReserved": "2026-04-15T09:33:02.614Z",
        "dateUpdated": "2026-05-27T11:54:33.819Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41681 (GCVE-0-2025-41681)

    Vulnerability from nvd – Published: 2025-07-21 09:31 – Updated: 2025-11-03 19:59
    VLAI
    Title
    Persistent Cross-Site Scripting via POST Requests Due to Improper Neutralization of Input
    Summary
    A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41681",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T12:30:26.217066Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T12:30:37.772Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:59:07.270Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content.\u003cbr\u003e"
                }
              ],
              "value": "A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:31:25.796Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Persistent Cross-Site Scripting via POST Requests Due to Improper Neutralization of Input",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41681",
        "datePublished": "2025-07-21T09:31:25.796Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:59:07.270Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41679 (GCVE-0-2025-41679)

    Vulnerability from nvd – Published: 2025-07-21 09:31 – Updated: 2025-11-03 19:59
    VLAI
    Title
    Unauthenticated Buffer Overflow in Conftool Service Leading to Denial of Service
    Summary
    An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41679",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T12:30:59.892256Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T12:31:24.437Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:59:05.914Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:31:04.713Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Unauthenticated Buffer Overflow in Conftool Service Leading to Denial of Service",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41679",
        "datePublished": "2025-07-21T09:31:04.713Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:59:05.914Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41678 (GCVE-0-2025-41678)

    Vulnerability from nvd – Published: 2025-07-21 09:30 – Updated: 2025-11-03 19:59
    VLAI
    Title
    SQL Injection via POST Requests Allowing Configuration Database Manipulation
    Summary
    A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41678",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T12:32:03.780398Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T12:32:09.542Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:59:04.559Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement.\u003cbr\u003e"
                }
              ],
              "value": "A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:30:44.484Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "SQL Injection via POST Requests Allowing Configuration Database Manipulation",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41678",
        "datePublished": "2025-07-21T09:30:44.484Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:59:04.559Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41677 (GCVE-0-2025-41677)

    Vulnerability from nvd – Published: 2025-07-21 09:30 – Updated: 2025-11-03 19:59
    VLAI
    Title
    Resource Exhaustion via POST Requests to send-mail Action
    Summary
    A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41677",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T15:00:24.440243Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T20:36:33.574Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:59:03.144Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession.\u003cbr\u003e"
                }
              ],
              "value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400 Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:30:28.614Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Resource Exhaustion via POST Requests to send-mail Action",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41677",
        "datePublished": "2025-07-21T09:30:28.614Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:59:03.144Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41676 (GCVE-0-2025-41676)

    Vulnerability from nvd – Published: 2025-07-21 09:30 – Updated: 2025-11-03 19:59
    VLAI
    Title
    Resource Exhaustion via POST Requests to send-sms Action
    Summary
    A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41676",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T15:00:32.085015Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T20:36:39.497Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:59:01.738Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession.\u003cbr\u003e"
                }
              ],
              "value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400 Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:30:07.473Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Resource Exhaustion via POST Requests to send-sms Action",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41676",
        "datePublished": "2025-07-21T09:30:07.473Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:59:01.738Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41675 (GCVE-0-2025-41675)

    Vulnerability from nvd – Published: 2025-07-21 09:29 – Updated: 2025-11-03 19:59
    VLAI
    Title
    Remote Command Injection via GET in Cloud Server Communication Script Due to Improper Input Neutralization
    Summary
    A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41675",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T15:00:42.591445Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T20:36:45.460Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:59:00.344Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
                }
              ],
              "value": "A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:29:57.024Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Remote Command Injection via GET in Cloud Server Communication Script Due to Improper Input Neutralization",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41675",
        "datePublished": "2025-07-21T09:29:57.024Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:59:00.344Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41674 (GCVE-0-2025-41674)

    Vulnerability from nvd – Published: 2025-07-21 09:29 – Updated: 2025-11-03 19:58
    VLAI
    Title
    Remote Command Injection in diagnostic Action Due to Improper Input Neutralization
    Summary
    A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41674",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T17:04:43.501527Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T17:05:33.656Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:58:58.776Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
                }
              ],
              "value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:29:43.181Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Remote Command Injection in diagnostic Action Due to Improper Input Neutralization",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41674",
        "datePublished": "2025-07-21T09:29:43.181Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:58:58.776Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41673 (GCVE-0-2025-41673)

    Vulnerability from nvd – Published: 2025-07-21 09:29 – Updated: 2025-11-03 19:58
    VLAI
    Title
    Remote Command Injection in send_sms Action Due to Improper Input Neutralization
    Summary
    A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41673",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T17:05:45.438732Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T17:06:11.768Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:58:57.413Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
                }
              ],
              "value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:29:32.129Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Remote Command Injection in send_sms Action Due to Improper Input Neutralization",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41673",
        "datePublished": "2025-07-21T09:29:32.129Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:58:57.413Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-45276 (GCVE-0-2024-45276)

    Vulnerability from nvd – Published: 2024-10-15 10:28 – Updated: 2025-01-24 06:32
    VLAI
    Title
    MB connect line/Helmholz: tmp directory exposed via webservice
    Summary
    An unauthenticated remote attacker can get read access to files in the "/tmp" directory due to missing authentication.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    mb_connect_line mbnet.mini Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex_100_firmware Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-10-15 08:00
    Credits
    Moritz Abrell SySS GmbH
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet.mini",
                "vendor": "mb_connect_line",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex_100_firmware",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-45276",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T13:28:49.058765Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T13:30:48.688Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-10-16T17:16:43.319Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-065.txt"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Moritz Abrell"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "SySS GmbH"
            }
          ],
          "datePublic": "2024-10-15T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker can get read access to files in the \"/tmp\" directory due to missing authentication.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker can get read access to files in the \"/tmp\" directory due to missing authentication."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-24T06:32:08.237Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
            }
          ],
          "source": {
            "advisory": "VDE-2024-056, VDE-2024-066",
            "defect": [
              "CERT@VDE#641679",
              "CERT@VDE#641692"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line/Helmholz: tmp directory exposed via webservice",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-45276",
        "datePublished": "2024-10-15T10:28:58.559Z",
        "dateReserved": "2024-08-26T09:19:01.267Z",
        "dateUpdated": "2025-01-24T06:32:08.237Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-45275 (GCVE-0-2024-45275)

    Vulnerability from nvd – Published: 2024-10-15 10:28 – Updated: 2024-10-16 17:39
    VLAI
    Title
    MB connect line/Helmholz: Hardcoded user accounts with hard-coded passwords
    Summary
    The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    mb_connect_line mbnet.mini Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex_100_firmware Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-10-15 08:00
    Credits
    Moritz Abrell SySS GmbH
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet.mini",
                "vendor": "mb_connect_line",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex_100_firmware",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-45275",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T13:31:57.475980Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T13:33:13.397Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-10-16T17:39:58.106Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-064.txt"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Moritz Abrell"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "SySS GmbH"
            }
          ],
          "datePublic": "2024-10-15T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices.\u003cbr\u003e"
                }
              ],
              "value": "The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-15T10:28:37.223Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
            }
          ],
          "source": {
            "advisory": "VDE-2024-056, VDE-2024-066",
            "defect": [
              "CERT@VDE#641679",
              "CERT@VDE#641692"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line/Helmholz: Hardcoded user accounts with hard-coded passwords",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-45275",
        "datePublished": "2024-10-15T10:28:37.223Z",
        "dateReserved": "2024-08-26T09:19:01.266Z",
        "dateUpdated": "2024-10-16T17:39:58.106Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-45274 (GCVE-0-2024-45274)

    Vulnerability from nvd – Published: 2024-10-15 10:28 – Updated: 2025-11-03 19:30
    VLAI
    Title
    MB connect line/Helmholz: Remote code execution via confnet service
    Summary
    An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    mb_connect_line mbnet.mini Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex_100_firmware Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-10-15 08:00
    Credits
    Moritz Abrell SySS GmbH
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet.mini",
                "vendor": "mb_connect_line",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex_100_firmware",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet.mini",
                "vendor": "mb_connect_line",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex_100_firmware",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-45274",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T13:33:38.579567Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T13:34:58.690Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:30:51.547Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-063.txt"
              },
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Moritz Abrell"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "SySS GmbH"
            }
          ],
          "datePublic": "2024-10-15T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-15T10:28:16.384Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
            }
          ],
          "source": {
            "advisory": "VDE-2024-056, VDE-2024-066",
            "defect": [
              "CERT@VDE#641679",
              "CERT@VDE#641692"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line/Helmholz: Remote code execution via confnet service",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-45274",
        "datePublished": "2024-10-15T10:28:16.384Z",
        "dateReserved": "2024-08-26T09:19:01.266Z",
        "dateUpdated": "2025-11-03T19:30:51.547Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-45273 (GCVE-0-2024-45273)

    Vulnerability from nvd – Published: 2024-10-15 10:27 – Updated: 2024-10-16 17:47
    VLAI
    Title
    MB connect line/Helmholz: Weak encryption of configuration file
    Summary
    An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-261 - Weak Encoding for Password
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    MB connect line mbNET/mbNET.rokey Affected: 0.0.0 , ≤ 8.2.0 (semver)
    Create a notification for this product.
    MB connect line mbNET HW1 Affected: 0.0.0 , ≤ 5.1.11 (semver)
    Create a notification for this product.
    MB connect line mbSPIDER Affected: 0.0.0 , ≤ 2.6.5 (semver)
    Create a notification for this product.
    MB connect line mbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    MB connect line mymbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ <= 2.2.13 (semver)
    Create a notification for this product.
    Helmholz REX200/250 Affected: 0.0.0 , ≤ <= 8.2.0 (semver)
    Create a notification for this product.
    Helmholz myREX24 V2 Affected: 0.0.0 , ≤ <= 2.16.2 (semver)
    Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0.0.0 , ≤ <= 2.16.2 (semver)
    Create a notification for this product.
    Helmholz REX300 Affected: 0.0.0 , ≤ <= 5.1.11 (semver)
    Create a notification for this product.
    mb_connect_line mbnet.mini Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbnet_mbnet.rokey Affected: 0 , ≤ 8.2.0 (semver)
        cpe:2.3:a:mbconnectline:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbnet_hw1 Affected: 0 , ≤ 5.1.11 (semver)
        cpe:2.3:a:mbconnectline:mbnet_hw1:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbspider Affected: 0 , ≤ 2.6.5 (semver)
        cpe:2.3:a:mbconnectline:mbspider:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbconnect24 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mymbconnect24 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex100 Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex_200 Affected: 0 , ≤ 8.2.0 (semver)
        cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex250 Affected: 0 , ≤ 8.2.0 (semver)
        cpe:2.3:a:helmholz:rex250:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz myrex24_v2 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz myrex24.virtual Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex300 Affected: 0 , ≤ 5.1.11 (semver)
        cpe:2.3:a:helmholz:rex300:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-10-15 08:00
    Credits
    Moritz Abrell SySS GmbH
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet.mini",
                "vendor": "mb_connect_line",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet_mbnet.rokey",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "8.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbnet_hw1:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet_hw1",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "5.1.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbspider:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbspider",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.6.5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbconnect24",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mymbconnect24",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex100",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex_200",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "8.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex250:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex250",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "8.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "myrex24_v2",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "myrex24.virtual",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex300:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex300",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "5.1.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-45273",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T18:22:26.955543Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T18:31:20.013Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-10-16T17:47:04.737Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-062.txt"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET/mbNET.rokey",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "8.2.0",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET HW1",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "5.1.11",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbSPIDER",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.6.5",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX200/250",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 8.2.0",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24 V2",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX300",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 5.1.11",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Moritz Abrell"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "SySS GmbH"
            }
          ],
          "datePublic": "2024-10-15T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-261",
                  "description": "CWE-261: Weak Encoding for Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-15T10:27:52.208Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-068"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-069"
            }
          ],
          "source": {
            "advisory": "VDE-2024-056, VDE-2024-066, VDE-2024-068, VDE-2024-069",
            "defect": [
              "CERT@VDE#641679",
              "CERT@VDE#641695",
              "CERT@VDE#641692",
              "CERT@VDE#641696"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line/Helmholz: Weak encryption of configuration file",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-45273",
        "datePublished": "2024-10-15T10:27:52.208Z",
        "dateReserved": "2024-08-26T09:19:01.266Z",
        "dateUpdated": "2024-10-16T17:47:04.737Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-45271 (GCVE-0-2024-45271)

    Vulnerability from nvd – Published: 2024-10-15 10:27 – Updated: 2025-08-26 14:14
    VLAI
    Title
    MB connect line/Helmholz: Remote code execution due to improper input validation
    Summary
    An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-94 - Improper Control of Generation of Code ('Code Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    mb_connect_line mbnet.mini Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*
    Create a notification for this product.
    rex100 helmholz Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:rex100:helmholz:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-10-15 08:00
    Credits
    Moritz Abrell SySS GmbH
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "mbnet.mini",
                "vendor": "mb_connect_line",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:rex100:helmholz:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "helmholz",
                "vendor": "rex100",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-45271",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T13:12:42.565246Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-26T14:14:12.044Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-10-16T17:49:30.446Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-059.txt"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Moritz Abrell"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "SySS GmbH"
            }
          ],
          "datePublic": "2024-10-15T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-94",
                  "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-22T06:55:23.671Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
            }
          ],
          "source": {
            "advisory": "VDE-2024-056, VDE-2024-066",
            "defect": [
              "CERT@VDE#641679",
              "CERT@VDE#641692"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line/Helmholz: Remote code execution due to improper input validation",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-45271",
        "datePublished": "2024-10-15T10:27:06.004Z",
        "dateReserved": "2024-08-26T09:19:01.266Z",
        "dateUpdated": "2025-08-26T14:14:12.044Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-40852 (GCVE-0-2026-40852)

    Vulnerability from cvelistv5 – Published: 2026-05-27 08:06 – Updated: 2026-05-27 11:54
    VLAI
    Title
    Command injection via malicious configuration
    Summary
    A highly authenticated attacker can alter the config generator injecting a payload into future created configurations. The device is not correctly checking this configuration value before passing it to an system execute leading to code execution. This can result in a total loss of confidentiality, integrity and availability.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Credits
    Moritz Abrell from SySS GmbH Christian Zäske from SySS GmbH
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-40852",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-27T11:44:33.329985Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-27T11:54:17.274Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET/mbNET.rokey",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "8.4.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "3.0.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET/mbNET.rokey",
              "vendor": "MB connect line",
              "versions": [
                {
                  "status": "affected",
                  "version": "8.4.4"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0.2"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX200/250",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "8.4.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "3.0.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX200/250",
              "vendor": "Helmholz",
              "versions": [
                {
                  "status": "affected",
                  "version": "8.4.4"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:mb_connect_line:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "8.4.4",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "3.0.2",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:mb_connect_line:mbnet:8.4.4:*:*:*:*:*:*:*",
                      "versionStartIncluding": "8.4.4",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:mb_connect_line:mbnet.mini:3.0.2:*:*:*:*:*:*:*",
                      "versionStartIncluding": "3.0.2",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:helmholz:rex200_250:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "8.4.4",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "3.0.2",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:helmholz:rex200_250:8.4.4:*:*:*:*:*:*:*",
                      "versionStartIncluding": "8.4.4",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:helmholz:rex100:3.0.2:*:*:*:*:*:*:*",
                      "versionStartIncluding": "3.0.2",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Moritz Abrell from SySS GmbH"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Christian Z\u00e4ske from SySS GmbH"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA highly authenticated attacker can alter the config generator injecting a payload into future created configurations. The device is not correctly checking this configuration value before passing it to an system execute leading to code execution. This can result in a total loss of confidentiality, integrity and availability.\u003c/p\u003e"
                }
              ],
              "value": "A highly authenticated attacker can alter the config generator injecting a payload into future created configurations. The device is not correctly checking this configuration value before passing it to an system execute leading to code execution. This can result in a total loss of confidentiality, integrity and availability."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-27T08:06:36.875Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-054/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-054",
            "defect": [
              "CERT@VDE#642070"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Command injection via malicious configuration",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-40852",
        "datePublished": "2026-05-27T08:06:36.875Z",
        "dateReserved": "2026-04-15T09:33:02.614Z",
        "dateUpdated": "2026-05-27T11:54:17.274Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-40851 (GCVE-0-2026-40851)

    Vulnerability from cvelistv5 – Published: 2026-05-27 08:06 – Updated: 2026-05-27 11:54
    VLAI
    Title
    Command injection via USB
    Summary
    A local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-1287 - Improper Validation of Specified Type of Input
    Assigner
    References
    Credits
    Moritz Abrell from SySS GmbH Christian Zäske from SySS GmbH
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-40851",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-27T11:44:44.253548Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-27T11:54:33.819Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET/mbNET.rokey",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "8.4.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "3.0.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET/mbNET.rokey",
              "vendor": "MB connect line",
              "versions": [
                {
                  "status": "affected",
                  "version": "8.4.4"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0.2"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX200/250",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "8.4.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "3.0.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX200/250",
              "vendor": "Helmholz",
              "versions": [
                {
                  "status": "affected",
                  "version": "8.4.4"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:mb_connect_line:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "8.4.4",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "3.0.2",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:mb_connect_line:mbnet:8.4.4:*:*:*:*:*:*:*",
                      "versionStartIncluding": "8.4.4",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:mb_connect_line:mbnet.mini:3.0.2:*:*:*:*:*:*:*",
                      "versionStartIncluding": "3.0.2",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:helmholz:rex200_250:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "8.4.4",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "3.0.2",
                      "versionStartIncluding": "0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:helmholz:rex200_250:8.4.4:*:*:*:*:*:*:*",
                      "versionStartIncluding": "8.4.4",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:helmholz:rex100:3.0.2:*:*:*:*:*:*:*",
                      "versionStartIncluding": "3.0.2",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Moritz Abrell from SySS GmbH"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Christian Z\u00e4ske from SySS GmbH"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability.\u003c/p\u003e"
                }
              ],
              "value": "A local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1287",
                  "description": "CWE-1287 Improper Validation of Specified Type of Input",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-27T08:06:21.815Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-054/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-054",
            "defect": [
              "CERT@VDE#642070"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Command injection via USB",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-40851",
        "datePublished": "2026-05-27T08:06:21.815Z",
        "dateReserved": "2026-04-15T09:33:02.614Z",
        "dateUpdated": "2026-05-27T11:54:33.819Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41681 (GCVE-0-2025-41681)

    Vulnerability from cvelistv5 – Published: 2025-07-21 09:31 – Updated: 2025-11-03 19:59
    VLAI
    Title
    Persistent Cross-Site Scripting via POST Requests Due to Improper Neutralization of Input
    Summary
    A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41681",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T12:30:26.217066Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T12:30:37.772Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:59:07.270Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content.\u003cbr\u003e"
                }
              ],
              "value": "A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:31:25.796Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Persistent Cross-Site Scripting via POST Requests Due to Improper Neutralization of Input",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41681",
        "datePublished": "2025-07-21T09:31:25.796Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:59:07.270Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41679 (GCVE-0-2025-41679)

    Vulnerability from cvelistv5 – Published: 2025-07-21 09:31 – Updated: 2025-11-03 19:59
    VLAI
    Title
    Unauthenticated Buffer Overflow in Conftool Service Leading to Denial of Service
    Summary
    An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41679",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T12:30:59.892256Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T12:31:24.437Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:59:05.914Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:31:04.713Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Unauthenticated Buffer Overflow in Conftool Service Leading to Denial of Service",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41679",
        "datePublished": "2025-07-21T09:31:04.713Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:59:05.914Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41678 (GCVE-0-2025-41678)

    Vulnerability from cvelistv5 – Published: 2025-07-21 09:30 – Updated: 2025-11-03 19:59
    VLAI
    Title
    SQL Injection via POST Requests Allowing Configuration Database Manipulation
    Summary
    A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41678",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T12:32:03.780398Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T12:32:09.542Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:59:04.559Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement.\u003cbr\u003e"
                }
              ],
              "value": "A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:30:44.484Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "SQL Injection via POST Requests Allowing Configuration Database Manipulation",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41678",
        "datePublished": "2025-07-21T09:30:44.484Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:59:04.559Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41677 (GCVE-0-2025-41677)

    Vulnerability from cvelistv5 – Published: 2025-07-21 09:30 – Updated: 2025-11-03 19:59
    VLAI
    Title
    Resource Exhaustion via POST Requests to send-mail Action
    Summary
    A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41677",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T15:00:24.440243Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T20:36:33.574Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:59:03.144Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession.\u003cbr\u003e"
                }
              ],
              "value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400 Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:30:28.614Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Resource Exhaustion via POST Requests to send-mail Action",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41677",
        "datePublished": "2025-07-21T09:30:28.614Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:59:03.144Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41676 (GCVE-0-2025-41676)

    Vulnerability from cvelistv5 – Published: 2025-07-21 09:30 – Updated: 2025-11-03 19:59
    VLAI
    Title
    Resource Exhaustion via POST Requests to send-sms Action
    Summary
    A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41676",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T15:00:32.085015Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T20:36:39.497Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:59:01.738Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession.\u003cbr\u003e"
                }
              ],
              "value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400 Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:30:07.473Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Resource Exhaustion via POST Requests to send-sms Action",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41676",
        "datePublished": "2025-07-21T09:30:07.473Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:59:01.738Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41675 (GCVE-0-2025-41675)

    Vulnerability from cvelistv5 – Published: 2025-07-21 09:29 – Updated: 2025-11-03 19:59
    VLAI
    Title
    Remote Command Injection via GET in Cloud Server Communication Script Due to Improper Input Neutralization
    Summary
    A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41675",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T15:00:42.591445Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T20:36:45.460Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:59:00.344Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
                }
              ],
              "value": "A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:29:57.024Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Remote Command Injection via GET in Cloud Server Communication Script Due to Improper Input Neutralization",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41675",
        "datePublished": "2025-07-21T09:29:57.024Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:59:00.344Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41674 (GCVE-0-2025-41674)

    Vulnerability from cvelistv5 – Published: 2025-07-21 09:29 – Updated: 2025-11-03 19:58
    VLAI
    Title
    Remote Command Injection in diagnostic Action Due to Improper Input Neutralization
    Summary
    A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41674",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T17:04:43.501527Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T17:05:33.656Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:58:58.776Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
                }
              ],
              "value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:29:43.181Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Remote Command Injection in diagnostic Action Due to Improper Input Neutralization",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41674",
        "datePublished": "2025-07-21T09:29:43.181Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:58:58.776Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41673 (GCVE-0-2025-41673)

    Vulnerability from cvelistv5 – Published: 2025-07-21 09:29 – Updated: 2025-11-03 19:58
    VLAI
    Title
    Remote Command Injection in send_sms Action Due to Improper Input Neutralization
    Summary
    A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
    Create a notification for this product.
    Credits
    F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41673",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T17:05:45.438732Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T17:06:11.768Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:58:57.413Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX 100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThan": "2.3.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
                }
              ],
              "value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-21T09:29:32.129Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-058"
            }
          ],
          "source": {
            "advisory": "VDE-2025-058, VDE-2025-059",
            "defect": [
              "CERT@VDE#641816",
              "CERT@VDE#641817"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Remote Command Injection in send_sms Action Due to Improper Input Neutralization",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41673",
        "datePublished": "2025-07-21T09:29:32.129Z",
        "dateReserved": "2025-04-16T11:17:48.308Z",
        "dateUpdated": "2025-11-03T19:58:57.413Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-45276 (GCVE-0-2024-45276)

    Vulnerability from cvelistv5 – Published: 2024-10-15 10:28 – Updated: 2025-01-24 06:32
    VLAI
    Title
    MB connect line/Helmholz: tmp directory exposed via webservice
    Summary
    An unauthenticated remote attacker can get read access to files in the "/tmp" directory due to missing authentication.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    mb_connect_line mbnet.mini Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex_100_firmware Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-10-15 08:00
    Credits
    Moritz Abrell SySS GmbH
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet.mini",
                "vendor": "mb_connect_line",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex_100_firmware",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-45276",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T13:28:49.058765Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T13:30:48.688Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-10-16T17:16:43.319Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-065.txt"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Moritz Abrell"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "SySS GmbH"
            }
          ],
          "datePublic": "2024-10-15T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker can get read access to files in the \"/tmp\" directory due to missing authentication.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker can get read access to files in the \"/tmp\" directory due to missing authentication."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-24T06:32:08.237Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
            }
          ],
          "source": {
            "advisory": "VDE-2024-056, VDE-2024-066",
            "defect": [
              "CERT@VDE#641679",
              "CERT@VDE#641692"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line/Helmholz: tmp directory exposed via webservice",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-45276",
        "datePublished": "2024-10-15T10:28:58.559Z",
        "dateReserved": "2024-08-26T09:19:01.267Z",
        "dateUpdated": "2025-01-24T06:32:08.237Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-45275 (GCVE-0-2024-45275)

    Vulnerability from cvelistv5 – Published: 2024-10-15 10:28 – Updated: 2024-10-16 17:39
    VLAI
    Title
    MB connect line/Helmholz: Hardcoded user accounts with hard-coded passwords
    Summary
    The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    mb_connect_line mbnet.mini Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex_100_firmware Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-10-15 08:00
    Credits
    Moritz Abrell SySS GmbH
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet.mini",
                "vendor": "mb_connect_line",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex_100_firmware",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-45275",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T13:31:57.475980Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T13:33:13.397Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-10-16T17:39:58.106Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-064.txt"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Moritz Abrell"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "SySS GmbH"
            }
          ],
          "datePublic": "2024-10-15T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices.\u003cbr\u003e"
                }
              ],
              "value": "The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-15T10:28:37.223Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
            }
          ],
          "source": {
            "advisory": "VDE-2024-056, VDE-2024-066",
            "defect": [
              "CERT@VDE#641679",
              "CERT@VDE#641692"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line/Helmholz: Hardcoded user accounts with hard-coded passwords",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-45275",
        "datePublished": "2024-10-15T10:28:37.223Z",
        "dateReserved": "2024-08-26T09:19:01.266Z",
        "dateUpdated": "2024-10-16T17:39:58.106Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-45274 (GCVE-0-2024-45274)

    Vulnerability from cvelistv5 – Published: 2024-10-15 10:28 – Updated: 2025-11-03 19:30
    VLAI
    Title
    MB connect line/Helmholz: Remote code execution via confnet service
    Summary
    An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    mb_connect_line mbnet.mini Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex_100_firmware Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-10-15 08:00
    Credits
    Moritz Abrell SySS GmbH
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet.mini",
                "vendor": "mb_connect_line",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex_100_firmware",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet.mini",
                "vendor": "mb_connect_line",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex_100_firmware",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-45274",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T13:33:38.579567Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T13:34:58.690Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T19:30:51.547Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-063.txt"
              },
              {
                "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Moritz Abrell"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "SySS GmbH"
            }
          ],
          "datePublic": "2024-10-15T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-15T10:28:16.384Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
            }
          ],
          "source": {
            "advisory": "VDE-2024-056, VDE-2024-066",
            "defect": [
              "CERT@VDE#641679",
              "CERT@VDE#641692"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line/Helmholz: Remote code execution via confnet service",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-45274",
        "datePublished": "2024-10-15T10:28:16.384Z",
        "dateReserved": "2024-08-26T09:19:01.266Z",
        "dateUpdated": "2025-11-03T19:30:51.547Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-45273 (GCVE-0-2024-45273)

    Vulnerability from cvelistv5 – Published: 2024-10-15 10:27 – Updated: 2024-10-16 17:47
    VLAI
    Title
    MB connect line/Helmholz: Weak encryption of configuration file
    Summary
    An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-261 - Weak Encoding for Password
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    MB connect line mbNET/mbNET.rokey Affected: 0.0.0 , ≤ 8.2.0 (semver)
    Create a notification for this product.
    MB connect line mbNET HW1 Affected: 0.0.0 , ≤ 5.1.11 (semver)
    Create a notification for this product.
    MB connect line mbSPIDER Affected: 0.0.0 , ≤ 2.6.5 (semver)
    Create a notification for this product.
    MB connect line mbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    MB connect line mymbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
    Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ <= 2.2.13 (semver)
    Create a notification for this product.
    Helmholz REX200/250 Affected: 0.0.0 , ≤ <= 8.2.0 (semver)
    Create a notification for this product.
    Helmholz myREX24 V2 Affected: 0.0.0 , ≤ <= 2.16.2 (semver)
    Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0.0.0 , ≤ <= 2.16.2 (semver)
    Create a notification for this product.
    Helmholz REX300 Affected: 0.0.0 , ≤ <= 5.1.11 (semver)
    Create a notification for this product.
    mb_connect_line mbnet.mini Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbnet_mbnet.rokey Affected: 0 , ≤ 8.2.0 (semver)
        cpe:2.3:a:mbconnectline:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbnet_hw1 Affected: 0 , ≤ 5.1.11 (semver)
        cpe:2.3:a:mbconnectline:mbnet_hw1:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbspider Affected: 0 , ≤ 2.6.5 (semver)
        cpe:2.3:a:mbconnectline:mbspider:*:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mbconnect24 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*
    Create a notification for this product.
    mbconnectline mymbconnect24 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex100 Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex_200 Affected: 0 , ≤ 8.2.0 (semver)
        cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex250 Affected: 0 , ≤ 8.2.0 (semver)
        cpe:2.3:a:helmholz:rex250:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz myrex24_v2 Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz myrex24.virtual Affected: 0 , ≤ 2.16.2 (semver)
        cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*
    Create a notification for this product.
    helmholz rex300 Affected: 0 , ≤ 5.1.11 (semver)
        cpe:2.3:a:helmholz:rex300:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-10-15 08:00
    Credits
    Moritz Abrell SySS GmbH
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet.mini",
                "vendor": "mb_connect_line",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet_mbnet.rokey",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "8.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbnet_hw1:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbnet_hw1",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "5.1.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbspider:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbspider",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.6.5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mbconnect24",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mymbconnect24",
                "vendor": "mbconnectline",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex100",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex_200",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "8.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex250:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex250",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "8.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "myrex24_v2",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "myrex24.virtual",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "2.16.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:helmholz:rex300:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "rex300",
                "vendor": "helmholz",
                "versions": [
                  {
                    "lessThanOrEqual": "5.1.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-45273",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T18:22:26.955543Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T18:31:20.013Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-10-16T17:47:04.737Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-062.txt"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET/mbNET.rokey",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "8.2.0",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET HW1",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "5.1.11",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbSPIDER",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.6.5",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX200/250",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 8.2.0",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24 V2",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX300",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 5.1.11",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Moritz Abrell"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "SySS GmbH"
            }
          ],
          "datePublic": "2024-10-15T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-261",
                  "description": "CWE-261: Weak Encoding for Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-15T10:27:52.208Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-068"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-069"
            }
          ],
          "source": {
            "advisory": "VDE-2024-056, VDE-2024-066, VDE-2024-068, VDE-2024-069",
            "defect": [
              "CERT@VDE#641679",
              "CERT@VDE#641695",
              "CERT@VDE#641692",
              "CERT@VDE#641696"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line/Helmholz: Weak encryption of configuration file",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-45273",
        "datePublished": "2024-10-15T10:27:52.208Z",
        "dateReserved": "2024-08-26T09:19:01.266Z",
        "dateUpdated": "2024-10-16T17:47:04.737Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-45271 (GCVE-0-2024-45271)

    Vulnerability from cvelistv5 – Published: 2024-10-15 10:27 – Updated: 2025-08-26 14:14
    VLAI
    Title
    MB connect line/Helmholz: Remote code execution due to improper input validation
    Summary
    An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-94 - Improper Control of Generation of Code ('Code Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ 2.2.13 (semver)
    Create a notification for this product.
    mb_connect_line mbnet.mini Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*
    Create a notification for this product.
    rex100 helmholz Affected: 0 , ≤ 2.2.13 (semver)
        cpe:2.3:a:rex100:helmholz:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-10-15 08:00
    Credits
    Moritz Abrell SySS GmbH
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "mbnet.mini",
                "vendor": "mb_connect_line",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:rex100:helmholz:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "helmholz",
                "vendor": "rex100",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-45271",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T13:12:42.565246Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-26T14:14:12.044Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-10-16T17:49:30.446Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-059.txt"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Moritz Abrell"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "SySS GmbH"
            }
          ],
          "datePublic": "2024-10-15T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-94",
                  "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-22T06:55:23.671Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
            },
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
            }
          ],
          "source": {
            "advisory": "VDE-2024-056, VDE-2024-066",
            "defect": [
              "CERT@VDE#641679",
              "CERT@VDE#641692"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "MB connect line/Helmholz: Remote code execution due to improper input validation",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-45271",
        "datePublished": "2024-10-15T10:27:06.004Z",
        "dateReserved": "2024-08-26T09:19:01.266Z",
        "dateUpdated": "2025-08-26T14:14:12.044Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }