Search criteria

32 vulnerabilities by Helmholz

CVE-2025-41688 (GCVE-0-2025-41688)

Vulnerability from cvelistv5 – Published: 2025-07-31 10:02 – Updated: 2025-07-31 13:17
VLAI?
Title
High Privilege RCE via LUA Sandbox Escape
Summary
A high privileged remote attacker can execute arbitrary OS commands using an undocumented method allowing to escape the implemented LUA sandbox.
CWE
  • CWE-653 - Improper Isolation or Compartmentalization
Assigner
Impacted products
Vendor Product Version
MB connect line mbNET HW1 Affected: 0.0.0 , ≤ 5.1.11 (semver)
Create a notification for this product.
    MB connect line mbNET/mbNET.rokey Affected: 0.0.0 , < 7.3.0 (semver)
Create a notification for this product.
    Helmholz REX 300 Affected: 0.0.0 , ≤ 5.1.11 (semver)
Create a notification for this product.
    Helmholz REX 200/250 Affected: 0.0.0 , < 7.3.0 (semver)
Create a notification for this product.
Credits
Marcel Rick-Cen
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41688",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-31T13:17:09.687569Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-31T13:17:23.918Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET HW1",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "5.1.11",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mbNET/mbNET.rokey",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "7.3.0",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX 300",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "5.1.11",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX 200/250",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "7.3.0",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Marcel Rick-Cen"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A high privileged remote attacker can execute arbitrary OS commands using an undocumented method allowing to escape the implemented LUA sandbox.\u003cbr\u003e"
            }
          ],
          "value": "A high privileged remote attacker can execute arbitrary OS commands using an undocumented method allowing to escape the implemented LUA sandbox."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-653",
              "description": "CWE-653 Improper Isolation or Compartmentalization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-31T10:02:49.655Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-065"
        },
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-069"
        }
      ],
      "source": {
        "advisory": "VDE-2025-065, VDE-2025-069",
        "defect": [
          "CERT@VDE#641828"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "High Privilege RCE via LUA Sandbox Escape",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-41688",
    "datePublished": "2025-07-31T10:02:49.655Z",
    "dateReserved": "2025-04-16T11:17:48.309Z",
    "dateUpdated": "2025-07-31T13:17:23.918Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-41681 (GCVE-0-2025-41681)

Vulnerability from cvelistv5 – Published: 2025-07-21 09:31 – Updated: 2025-11-03 19:59
VLAI?
Title
Persistent Cross-Site Scripting via POST Requests Due to Improper Neutralization of Input
Summary
A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
Credits
F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41681",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-21T12:30:26.217066Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-21T12:30:37.772Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:59:07.270Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.mini",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX 100",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content.\u003cbr\u003e"
            }
          ],
          "value": "A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-21T09:31:25.796Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-058"
        }
      ],
      "source": {
        "advisory": "VDE-2025-058, VDE-2025-059",
        "defect": [
          "CERT@VDE#641816",
          "CERT@VDE#641817"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Persistent Cross-Site Scripting via POST Requests Due to Improper Neutralization of Input",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-41681",
    "datePublished": "2025-07-21T09:31:25.796Z",
    "dateReserved": "2025-04-16T11:17:48.308Z",
    "dateUpdated": "2025-11-03T19:59:07.270Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-41679 (GCVE-0-2025-41679)

Vulnerability from cvelistv5 – Published: 2025-07-21 09:31 – Updated: 2025-11-03 19:59
VLAI?
Title
Unauthenticated Buffer Overflow in Conftool Service Leading to Denial of Service
Summary
An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service.
CWE
Assigner
Impacted products
Vendor Product Version
MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
Credits
F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41679",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-21T12:30:59.892256Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-21T12:31:24.437Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:59:05.914Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.mini",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX 100",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service.\u003cbr\u003e"
            }
          ],
          "value": "An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-21T09:31:04.713Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-058"
        }
      ],
      "source": {
        "advisory": "VDE-2025-058, VDE-2025-059",
        "defect": [
          "CERT@VDE#641816",
          "CERT@VDE#641817"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Unauthenticated Buffer Overflow in Conftool Service Leading to Denial of Service",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-41679",
    "datePublished": "2025-07-21T09:31:04.713Z",
    "dateReserved": "2025-04-16T11:17:48.308Z",
    "dateUpdated": "2025-11-03T19:59:05.914Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-41678 (GCVE-0-2025-41678)

Vulnerability from cvelistv5 – Published: 2025-07-21 09:30 – Updated: 2025-11-03 19:59
VLAI?
Title
SQL Injection via POST Requests Allowing Configuration Database Manipulation
Summary
A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
Impacted products
Vendor Product Version
MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
Credits
F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41678",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-21T12:32:03.780398Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-21T12:32:09.542Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:59:04.559Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.mini",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX 100",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement.\u003cbr\u003e"
            }
          ],
          "value": "A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-21T09:30:44.484Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-058"
        }
      ],
      "source": {
        "advisory": "VDE-2025-058, VDE-2025-059",
        "defect": [
          "CERT@VDE#641816",
          "CERT@VDE#641817"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "SQL Injection via POST Requests Allowing Configuration Database Manipulation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-41678",
    "datePublished": "2025-07-21T09:30:44.484Z",
    "dateReserved": "2025-04-16T11:17:48.308Z",
    "dateUpdated": "2025-11-03T19:59:04.559Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-41677 (GCVE-0-2025-41677)

Vulnerability from cvelistv5 – Published: 2025-07-21 09:30 – Updated: 2025-11-03 19:59
VLAI?
Title
Resource Exhaustion via POST Requests to send-mail Action
Summary
A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession.
CWE
  • CWE-400 - Uncontrolled Resource Consumption
Assigner
Impacted products
Vendor Product Version
MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
Credits
F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41677",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-21T15:00:24.440243Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-21T20:36:33.574Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:59:03.144Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.mini",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX 100",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession.\u003cbr\u003e"
            }
          ],
          "value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400 Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-21T09:30:28.614Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-058"
        }
      ],
      "source": {
        "advisory": "VDE-2025-058, VDE-2025-059",
        "defect": [
          "CERT@VDE#641816",
          "CERT@VDE#641817"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Resource Exhaustion via POST Requests to send-mail Action",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-41677",
    "datePublished": "2025-07-21T09:30:28.614Z",
    "dateReserved": "2025-04-16T11:17:48.308Z",
    "dateUpdated": "2025-11-03T19:59:03.144Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-41676 (GCVE-0-2025-41676)

Vulnerability from cvelistv5 – Published: 2025-07-21 09:30 – Updated: 2025-11-03 19:59
VLAI?
Title
Resource Exhaustion via POST Requests to send-sms Action
Summary
A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession.
CWE
  • CWE-400 - Uncontrolled Resource Consumption
Assigner
Impacted products
Vendor Product Version
MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
Credits
F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41676",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-21T15:00:32.085015Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-21T20:36:39.497Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:59:01.738Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.mini",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX 100",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession.\u003cbr\u003e"
            }
          ],
          "value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400 Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-21T09:30:07.473Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-058"
        }
      ],
      "source": {
        "advisory": "VDE-2025-058, VDE-2025-059",
        "defect": [
          "CERT@VDE#641816",
          "CERT@VDE#641817"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Resource Exhaustion via POST Requests to send-sms Action",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-41676",
    "datePublished": "2025-07-21T09:30:07.473Z",
    "dateReserved": "2025-04-16T11:17:48.308Z",
    "dateUpdated": "2025-11-03T19:59:01.738Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-41675 (GCVE-0-2025-41675)

Vulnerability from cvelistv5 – Published: 2025-07-21 09:29 – Updated: 2025-11-03 19:59
VLAI?
Title
Remote Command Injection via GET in Cloud Server Communication Script Due to Improper Input Neutralization
Summary
A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Impacted products
Vendor Product Version
MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
Credits
F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41675",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-21T15:00:42.591445Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-21T20:36:45.460Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:59:00.344Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.mini",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX 100",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
            }
          ],
          "value": "A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-21T09:29:57.024Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-058"
        }
      ],
      "source": {
        "advisory": "VDE-2025-058, VDE-2025-059",
        "defect": [
          "CERT@VDE#641816",
          "CERT@VDE#641817"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Remote Command Injection via GET in Cloud Server Communication Script Due to Improper Input Neutralization",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-41675",
    "datePublished": "2025-07-21T09:29:57.024Z",
    "dateReserved": "2025-04-16T11:17:48.308Z",
    "dateUpdated": "2025-11-03T19:59:00.344Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-41674 (GCVE-0-2025-41674)

Vulnerability from cvelistv5 – Published: 2025-07-21 09:29 – Updated: 2025-11-03 19:58
VLAI?
Title
Remote Command Injection in diagnostic Action Due to Improper Input Neutralization
Summary
A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Impacted products
Vendor Product Version
MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
Credits
F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41674",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-21T17:04:43.501527Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-21T17:05:33.656Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:58:58.776Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.mini",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX 100",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
            }
          ],
          "value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-21T09:29:43.181Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-058"
        }
      ],
      "source": {
        "advisory": "VDE-2025-058, VDE-2025-059",
        "defect": [
          "CERT@VDE#641816",
          "CERT@VDE#641817"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Remote Command Injection in diagnostic Action Due to Improper Input Neutralization",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-41674",
    "datePublished": "2025-07-21T09:29:43.181Z",
    "dateReserved": "2025-04-16T11:17:48.308Z",
    "dateUpdated": "2025-11-03T19:58:58.776Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-41673 (GCVE-0-2025-41673)

Vulnerability from cvelistv5 – Published: 2025-07-21 09:29 – Updated: 2025-11-03 19:58
VLAI?
Title
Remote Command Injection in send_sms Action Due to Improper Input Neutralization
Summary
A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Impacted products
Vendor Product Version
MB connect line mbNET.mini Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
    Helmholz REX 100 Affected: 0.0.0 , < 2.3.3 (semver)
Create a notification for this product.
Credits
F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41673",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-21T17:05:45.438732Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-21T17:06:11.768Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:58:57.413Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.mini",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX 100",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.3.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
            }
          ],
          "value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-21T09:29:32.129Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-058"
        }
      ],
      "source": {
        "advisory": "VDE-2025-058, VDE-2025-059",
        "defect": [
          "CERT@VDE#641816",
          "CERT@VDE#641817"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Remote Command Injection in send_sms Action Due to Improper Input Neutralization",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-41673",
    "datePublished": "2025-07-21T09:29:32.129Z",
    "dateReserved": "2025-04-16T11:17:48.308Z",
    "dateUpdated": "2025-11-03T19:58:57.413Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-3092 (GCVE-0-2025-3092)

Vulnerability from cvelistv5 – Published: 2025-06-24 08:14 – Updated: 2025-06-24 13:55
VLAI?
Title
MB connect line: Observable response discrepancy in mbCONNECT24/mymbCONNECT24
Summary
An unauthenticated remote attacker can enumerate valid user names from an unprotected endpoint.
CWE
  • CWE-204 - Observable Response Discrepancy
Assigner
Impacted products
Credits
Peter Husted Simonsen Irwin Przeperski Eviden
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3092",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-24T13:55:22.243364Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-24T13:55:34.477Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "myREX24",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.18.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.16.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24.virtual",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.18.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24.virtual",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.16.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.16.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mymbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.18.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mymbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.18.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mymbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.16.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Peter Husted Simonsen"
        },
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Irwin Przeperski"
        },
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Eviden"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn unauthenticated remote attacker can enumerate valid user names from an unprotected endpoint.\u003c/p\u003e"
            }
          ],
          "value": "An unauthenticated remote attacker can enumerate valid user names from an unprotected endpoint."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-204",
              "description": "CWE-204:Observable Response Discrepancy",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-24T08:14:31.864Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/en/advisories/VDE-2025-035"
        },
        {
          "url": "https://certvde.com/en/advisories/VDE-2025-038"
        }
      ],
      "source": {
        "advisory": "VDE-2025-035",
        "defect": [
          "CERT@VDE#641772"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "MB connect line: Observable response discrepancy in mbCONNECT24/mymbCONNECT24",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-3092",
    "datePublished": "2025-06-24T08:14:31.864Z",
    "dateReserved": "2025-04-01T13:41:23.509Z",
    "dateUpdated": "2025-06-24T13:55:34.477Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3091 (GCVE-0-2025-3091)

Vulnerability from cvelistv5 – Published: 2025-06-24 08:10 – Updated: 2025-06-24 13:56
VLAI?
Title
MB connect line: Authorization bypass in mbCONNECT24/mymbCONNECT24
Summary
An low privileged remote attacker in possession of the second factor for another user can login as that user without knowledge of the other user`s password.
CWE
  • CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
Impacted products
Credits
Peter Husted Simonsen Irwin Przeperski Eviden
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3091",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-24T13:55:50.726894Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-24T13:56:13.121Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.16.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mymbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.18.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mymbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.18.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mymbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.16.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.18.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.16.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24.virtual",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.18.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24.virtual",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.16.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Peter Husted Simonsen"
        },
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Irwin Przeperski"
        },
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Eviden"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An low privileged remote attacker in possession of the second factor for another user can login as that user without knowledge of the other user`s password."
            }
          ],
          "value": "An low privileged remote attacker in possession of the second factor for another user can login as that user without knowledge of the other user`s password."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-639",
              "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-24T08:10:29.717Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/en/advisories/VDE-2025-035"
        },
        {
          "url": "https://certvde.com/en/advisories/VDE-2025-038"
        }
      ],
      "source": {
        "advisory": "VDE-2025-035",
        "defect": [
          "CERT@VDE#641772"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "MB connect line: Authorization bypass in mbCONNECT24/mymbCONNECT24",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-3091",
    "datePublished": "2025-06-24T08:10:29.717Z",
    "dateReserved": "2025-04-01T13:41:22.429Z",
    "dateUpdated": "2025-06-24T13:56:13.121Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3090 (GCVE-0-2025-3090)

Vulnerability from cvelistv5 – Published: 2025-06-24 08:05 – Updated: 2025-06-24 14:18
VLAI?
Title
MB connect line: Missing Authentication in mbCONNECT24/mymbCONNECT24
Summary
An unauthenticated remote attacker can obtain limited sensitive information and/or DoS the device due to missing authentication for critical function.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
Impacted products
Vendor Product Version
MB connect line mbCONNECT24 Affected: 0 , < 2.18.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3090",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-24T14:17:56.862943Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-24T14:18:57.831Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.18.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mymbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThan": "2.18.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.18.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24.virtual",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "2.18.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An unauthenticated remote attacker can obtain limited sensitive information and/or DoS the device due to missing authentication for critical function."
            }
          ],
          "value": "An unauthenticated remote attacker can obtain limited sensitive information and/or DoS the device due to missing authentication for critical function."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-24T08:05:15.547Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/en/advisories/VDE-2025-034"
        },
        {
          "url": "https://certvde.com/en/advisories/VDE-2025-037"
        }
      ],
      "source": {
        "advisory": "VDE-2025-034",
        "defect": [
          "CERT@VDE#641771"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "MB connect line: Missing Authentication in mbCONNECT24/mymbCONNECT24",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-3090",
    "datePublished": "2025-06-24T08:05:15.547Z",
    "dateReserved": "2025-04-01T13:41:20.503Z",
    "dateUpdated": "2025-06-24T14:18:57.831Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-45276 (GCVE-0-2024-45276)

Vulnerability from cvelistv5 – Published: 2024-10-15 10:28 – Updated: 2025-01-24 06:32
VLAI?
Title
MB connect line/Helmholz: tmp directory exposed via webservice
Summary
An unauthenticated remote attacker can get read access to files in the "/tmp" directory due to missing authentication.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
Impacted products
Vendor Product Version
MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ 2.2.13 (semver)
Create a notification for this product.
Credits
Moritz Abrell SySS GmbH
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "mbnet.mini",
            "vendor": "mb_connect_line",
            "versions": [
              {
                "lessThanOrEqual": "2.2.13",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "rex_100_firmware",
            "vendor": "helmholz",
            "versions": [
              {
                "lessThanOrEqual": "2.2.13",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-45276",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-15T13:28:49.058765Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-15T13:30:48.688Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-10-16T17:16:43.319Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-065.txt"
          }
        ],
        "title": "CVE Program Container",
        "x_generator": {
          "engine": "ADPogram 0.0.1"
        }
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.mini",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.2.13",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX100",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.2.13",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Moritz Abrell"
        },
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "SySS GmbH"
        }
      ],
      "datePublic": "2024-10-15T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An unauthenticated remote attacker can get read access to files in the \"/tmp\" directory due to missing authentication.\u003cbr\u003e"
            }
          ],
          "value": "An unauthenticated remote attacker can get read access to files in the \"/tmp\" directory due to missing authentication."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-24T06:32:08.237Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
        },
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
        }
      ],
      "source": {
        "advisory": "VDE-2024-056, VDE-2024-066",
        "defect": [
          "CERT@VDE#641679",
          "CERT@VDE#641692"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "MB connect line/Helmholz: tmp directory exposed via webservice",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2024-45276",
    "datePublished": "2024-10-15T10:28:58.559Z",
    "dateReserved": "2024-08-26T09:19:01.267Z",
    "dateUpdated": "2025-01-24T06:32:08.237Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-45275 (GCVE-0-2024-45275)

Vulnerability from cvelistv5 – Published: 2024-10-15 10:28 – Updated: 2024-10-16 17:39
VLAI?
Title
MB connect line/Helmholz: Hardcoded user accounts with hard-coded passwords
Summary
The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
Impacted products
Vendor Product Version
MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ 2.2.13 (semver)
Create a notification for this product.
Credits
Moritz Abrell SySS GmbH
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "mbnet.mini",
            "vendor": "mb_connect_line",
            "versions": [
              {
                "lessThanOrEqual": "2.2.13",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "rex_100_firmware",
            "vendor": "helmholz",
            "versions": [
              {
                "lessThanOrEqual": "2.2.13",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-45275",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-15T13:31:57.475980Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-15T13:33:13.397Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-10-16T17:39:58.106Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-064.txt"
          }
        ],
        "title": "CVE Program Container",
        "x_generator": {
          "engine": "ADPogram 0.0.1"
        }
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.mini",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.2.13",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX100",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.2.13",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Moritz Abrell"
        },
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "SySS GmbH"
        }
      ],
      "datePublic": "2024-10-15T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices.\u003cbr\u003e"
            }
          ],
          "value": "The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-15T10:28:37.223Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
        },
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
        }
      ],
      "source": {
        "advisory": "VDE-2024-056, VDE-2024-066",
        "defect": [
          "CERT@VDE#641679",
          "CERT@VDE#641692"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "MB connect line/Helmholz: Hardcoded user accounts with hard-coded passwords",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2024-45275",
    "datePublished": "2024-10-15T10:28:37.223Z",
    "dateReserved": "2024-08-26T09:19:01.266Z",
    "dateUpdated": "2024-10-16T17:39:58.106Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-45274 (GCVE-0-2024-45274)

Vulnerability from cvelistv5 – Published: 2024-10-15 10:28 – Updated: 2025-11-03 19:30
VLAI?
Title
MB connect line/Helmholz: Remote code execution via confnet service
Summary
An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
Impacted products
Vendor Product Version
MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ 2.2.13 (semver)
Create a notification for this product.
Credits
Moritz Abrell SySS GmbH
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "mbnet.mini",
            "vendor": "mb_connect_line",
            "versions": [
              {
                "lessThanOrEqual": "2.2.13",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "rex_100_firmware",
            "vendor": "helmholz",
            "versions": [
              {
                "lessThanOrEqual": "2.2.13",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "mbnet.mini",
            "vendor": "mb_connect_line",
            "versions": [
              {
                "lessThanOrEqual": "2.2.13",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "rex_100_firmware",
            "vendor": "helmholz",
            "versions": [
              {
                "lessThanOrEqual": "2.2.13",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-45274",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-15T13:33:38.579567Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-15T13:34:58.690Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:30:51.547Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-063.txt"
          },
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/38"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.mini",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.2.13",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX100",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.2.13",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Moritz Abrell"
        },
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "SySS GmbH"
        }
      ],
      "datePublic": "2024-10-15T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication.\u003cbr\u003e"
            }
          ],
          "value": "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-15T10:28:16.384Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
        },
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
        }
      ],
      "source": {
        "advisory": "VDE-2024-056, VDE-2024-066",
        "defect": [
          "CERT@VDE#641679",
          "CERT@VDE#641692"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "MB connect line/Helmholz: Remote code execution via confnet service",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2024-45274",
    "datePublished": "2024-10-15T10:28:16.384Z",
    "dateReserved": "2024-08-26T09:19:01.266Z",
    "dateUpdated": "2025-11-03T19:30:51.547Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-45273 (GCVE-0-2024-45273)

Vulnerability from cvelistv5 – Published: 2024-10-15 10:27 – Updated: 2024-10-16 17:47
VLAI?
Title
MB connect line/Helmholz: Weak encryption of configuration file
Summary
An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.
CWE
  • CWE-261 - Weak Encoding for Password
Assigner
Impacted products
Vendor Product Version
MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
Create a notification for this product.
    MB connect line mbNET/mbNET.rokey Affected: 0.0.0 , ≤ 8.2.0 (semver)
Create a notification for this product.
    MB connect line mbNET HW1 Affected: 0.0.0 , ≤ 5.1.11 (semver)
Create a notification for this product.
    MB connect line mbSPIDER Affected: 0.0.0 , ≤ 2.6.5 (semver)
Create a notification for this product.
    MB connect line mbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
Create a notification for this product.
    MB connect line mymbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ <= 2.2.13 (semver)
Create a notification for this product.
    Helmholz REX200/250 Affected: 0.0.0 , ≤ <= 8.2.0 (semver)
Create a notification for this product.
    Helmholz myREX24 V2 Affected: 0.0.0 , ≤ <= 2.16.2 (semver)
Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0.0.0 , ≤ <= 2.16.2 (semver)
Create a notification for this product.
    Helmholz REX300 Affected: 0.0.0 , ≤ <= 5.1.11 (semver)
Create a notification for this product.
Credits
Moritz Abrell SySS GmbH
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "mbnet.mini",
            "vendor": "mb_connect_line",
            "versions": [
              {
                "lessThanOrEqual": "2.2.13",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mbconnectline:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "mbnet_mbnet.rokey",
            "vendor": "mbconnectline",
            "versions": [
              {
                "lessThanOrEqual": "8.2.0",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mbconnectline:mbnet_hw1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "mbnet_hw1",
            "vendor": "mbconnectline",
            "versions": [
              {
                "lessThanOrEqual": "5.1.11",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mbconnectline:mbspider:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "mbspider",
            "vendor": "mbconnectline",
            "versions": [
              {
                "lessThanOrEqual": "2.6.5",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "mbconnect24",
            "vendor": "mbconnectline",
            "versions": [
              {
                "lessThanOrEqual": "2.16.2",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "mymbconnect24",
            "vendor": "mbconnectline",
            "versions": [
              {
                "lessThanOrEqual": "2.16.2",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "rex100",
            "vendor": "helmholz",
            "versions": [
              {
                "lessThanOrEqual": "2.2.13",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "rex_200",
            "vendor": "helmholz",
            "versions": [
              {
                "lessThanOrEqual": "8.2.0",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:helmholz:rex250:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "rex250",
            "vendor": "helmholz",
            "versions": [
              {
                "lessThanOrEqual": "8.2.0",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "myrex24_v2",
            "vendor": "helmholz",
            "versions": [
              {
                "lessThanOrEqual": "2.16.2",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "myrex24.virtual",
            "vendor": "helmholz",
            "versions": [
              {
                "lessThanOrEqual": "2.16.2",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:helmholz:rex300:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "rex300",
            "vendor": "helmholz",
            "versions": [
              {
                "lessThanOrEqual": "5.1.11",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-45273",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-15T18:22:26.955543Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-15T18:31:20.013Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-10-16T17:47:04.737Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-062.txt"
          }
        ],
        "title": "CVE Program Container",
        "x_generator": {
          "engine": "ADPogram 0.0.1"
        }
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.mini",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.2.13",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mbNET/mbNET.rokey",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "8.2.0",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mbNET HW1",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "5.1.11",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mbSPIDER",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.6.5",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.16.2",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mymbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.16.2",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX100",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "\u003c= 2.2.13",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX200/250",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "\u003c= 8.2.0",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24 V2",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "\u003c= 2.16.2",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24.virtual",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "\u003c= 2.16.2",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX300",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "\u003c= 5.1.11",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Moritz Abrell"
        },
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "SySS GmbH"
        }
      ],
      "datePublic": "2024-10-15T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.\u003cbr\u003e"
            }
          ],
          "value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-261",
              "description": "CWE-261: Weak Encoding for Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-15T10:27:52.208Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
        },
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
        },
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-068"
        },
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-069"
        }
      ],
      "source": {
        "advisory": "VDE-2024-056, VDE-2024-066, VDE-2024-068, VDE-2024-069",
        "defect": [
          "CERT@VDE#641679",
          "CERT@VDE#641695",
          "CERT@VDE#641692",
          "CERT@VDE#641696"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "MB connect line/Helmholz: Weak encryption of configuration file",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2024-45273",
    "datePublished": "2024-10-15T10:27:52.208Z",
    "dateReserved": "2024-08-26T09:19:01.266Z",
    "dateUpdated": "2024-10-16T17:47:04.737Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-45272 (GCVE-0-2024-45272)

Vulnerability from cvelistv5 – Published: 2024-10-15 10:27 – Updated: 2024-10-16 17:36
VLAI?
Title
MB connect line/Helmholz: Generation of weak passwords vulnerability
Summary
An unauthenticated remote attacker can perform a brute-force attack on the credentials of the remote service portal with a high chance of success, resulting in connection lost.
CWE
Assigner
Impacted products
Vendor Product Version
MB connect line mbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
Create a notification for this product.
    MB connect line mymbCONNECT24 Affected: 0.0.0 , ≤ 2.16.2 (semver)
Create a notification for this product.
    Helmholz myREX24 V2 Affected: 0.0.0 , ≤ 2.16.2 (semver)
Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0.0.0 , ≤ 2.16.2 (semver)
Create a notification for this product.
Credits
Moritz Abrell SySS GmbH
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "mbconnect24",
            "vendor": "mbconnectline",
            "versions": [
              {
                "lessThanOrEqual": "2.16.2",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "mymbconnect24",
            "vendor": "mbconnectline",
            "versions": [
              {
                "lessThanOrEqual": "2.16.2",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "myrex24_v2",
            "vendor": "helmholz",
            "versions": [
              {
                "lessThanOrEqual": "2.16.2",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "myrex24.virtual",
            "vendor": "helmholz",
            "versions": [
              {
                "lessThanOrEqual": "2.16.2",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-45272",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-15T13:40:14.338031Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-15T13:43:55.942Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-10-16T17:36:22.123Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-061.txt"
          }
        ],
        "title": "CVE Program Container",
        "x_generator": {
          "engine": "ADPogram 0.0.1"
        }
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.16.2",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mymbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.16.2",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24 V2",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.16.2",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24.virtual",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.16.2",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Moritz Abrell"
        },
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "SySS GmbH"
        }
      ],
      "datePublic": "2024-10-15T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An unauthenticated remote attacker can perform a brute-force attack on the credentials of the remote service portal with a high chance of success, resulting in connection lost.\u003cbr\u003e"
            }
          ],
          "value": "An unauthenticated remote attacker can perform a brute-force attack on the credentials of the remote service portal with a high chance of success, resulting in connection lost."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1391",
              "description": "CWE-1391: Use of Weak Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-15T10:27:32.688Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-068"
        },
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-069"
        }
      ],
      "source": {
        "advisory": "VDE-2024-068, VDE-2024-069",
        "defect": [
          "CERT@VDE#641695",
          "CERT@VDE#641696"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "MB connect line/Helmholz: Generation of weak passwords vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2024-45272",
    "datePublished": "2024-10-15T10:27:32.688Z",
    "dateReserved": "2024-08-26T09:19:01.266Z",
    "dateUpdated": "2024-10-16T17:36:22.123Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-45271 (GCVE-0-2024-45271)

Vulnerability from cvelistv5 – Published: 2024-10-15 10:27 – Updated: 2025-08-26 14:14
VLAI?
Title
MB connect line/Helmholz: Remote code execution due to improper input validation
Summary
An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation.
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
Impacted products
Vendor Product Version
MB connect line mbNET.mini Affected: 0.0.0 , ≤ 2.2.13 (semver)
Create a notification for this product.
    Helmholz REX100 Affected: 0.0.0 , ≤ 2.2.13 (semver)
Create a notification for this product.
Credits
Moritz Abrell SySS GmbH
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mbnet.mini",
            "vendor": "mb_connect_line",
            "versions": [
              {
                "lessThanOrEqual": "2.2.13",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:rex100:helmholz:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "helmholz",
            "vendor": "rex100",
            "versions": [
              {
                "lessThanOrEqual": "2.2.13",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-45271",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-15T13:12:42.565246Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-26T14:14:12.044Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-10-16T17:49:30.446Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-059.txt"
          }
        ],
        "title": "CVE Program Container",
        "x_generator": {
          "engine": "ADPogram 0.0.1"
        }
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.mini",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.2.13",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX100",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.2.13",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Moritz Abrell"
        },
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "SySS GmbH"
        }
      ],
      "datePublic": "2024-10-15T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation.\u003cbr\u003e"
            }
          ],
          "value": "An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-22T06:55:23.671Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
        },
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
        }
      ],
      "source": {
        "advisory": "VDE-2024-056, VDE-2024-066",
        "defect": [
          "CERT@VDE#641679",
          "CERT@VDE#641692"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "MB connect line/Helmholz: Remote code execution due to improper input validation",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2024-45271",
    "datePublished": "2024-10-15T10:27:06.004Z",
    "dateReserved": "2024-08-26T09:19:01.266Z",
    "dateUpdated": "2025-08-26T14:14:12.044Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-5672 (GCVE-0-2024-5672)

Vulnerability from cvelistv5 – Published: 2024-07-03 12:26 – Updated: 2025-02-13 17:54
VLAI?
Title
Red Lion Europe: mbNET.mini vulnerable to OS command injection
Summary
A high privileged remote attacker can execute arbitrary system commands via GET requests due to improper neutralization of special elements used in an OS command.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Impacted products
Vendor Product Version
Red Lion Europe mbNET.mini Affected: 0 , ≤ 2.2.11 (semver)
Create a notification for this product.
    Helmholz REX 100 Affected: 0 , ≤ 2.2.11 (semver)
Create a notification for this product.
Credits
Sebastian Dietz CyberDanube
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "rex_100_firmware",
            "vendor": "helmholz",
            "versions": [
              {
                "lessThanOrEqual": "2.2.11",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:redlion:mbnet_mini:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "mbnet_mini",
            "vendor": "redlion",
            "versions": [
              {
                "lessThanOrEqual": "2.2.11",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5672",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-11T19:03:51.830907Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-11T19:49:42.244Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:18:06.930Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2024-030"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2024-032"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2024/Jul/6"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.mini",
          "vendor": "Red Lion Europe",
          "versions": [
            {
              "lessThanOrEqual": "2.2.11",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX 100",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.2.11",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Sebastian Dietz"
        },
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "CyberDanube"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A high privileged remote attacker can\u0026nbsp;execute arbitrary system commands via GET requests due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
            }
          ],
          "value": "A high privileged remote attacker can\u00a0execute arbitrary system commands via GET requests due to improper neutralization of special elements used in an OS command."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-04T06:06:11.012Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-030"
        },
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-032"
        },
        {
          "url": "http://seclists.org/fulldisclosure/2024/Jul/6"
        }
      ],
      "source": {
        "advisory": "VDE-2024-030",
        "defect": [
          "CERT@VDE#641635"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Red Lion Europe: mbNET.mini vulnerable to OS command injection",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2024-5672",
    "datePublished": "2024-07-03T12:26:44.599Z",
    "dateReserved": "2024-06-06T07:27:39.719Z",
    "dateUpdated": "2025-02-13T17:54:25.437Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-4834 (GCVE-0-2023-4834)

Vulnerability from cvelistv5 – Published: 2023-10-16 08:40 – Updated: 2024-09-16 18:17
VLAI?
Summary
In Red Lion Europe mbCONNECT24 and mymbCONNECT24 and Helmholz myREX24 and myREX24.virtual up to and including 2.14.2 an improperly implemented access validation allows an authenticated, low privileged attacker to gain read access to limited, non-critical device information in his account he should not have access to.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
Impacted products
Vendor Product Version
Red Lion Europe mbCONNECT24 Affected: 0 , ≤ 2.14.2 (semver)
Create a notification for this product.
    Red Lion Europe mymbCONNECT24 Affected: 0 , ≤ 2.14.2 (semver)
Create a notification for this product.
    Helmholz myREX24 Affected: 0 , ≤ 2.14.2 (semver)
Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0 , ≤ 2.14.2 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:38:00.778Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2023-041"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2023-043"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-4834",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-16T18:16:53.810599Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-16T18:17:07.881Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbCONNECT24",
          "vendor": "Red Lion Europe",
          "versions": [
            {
              "lessThanOrEqual": "2.14.2",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mymbCONNECT24",
          "vendor": "Red Lion Europe",
          "versions": [
            {
              "lessThanOrEqual": "2.14.2",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.14.2",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24.virtual",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.14.2",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2023-10-16T08:40:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eIn \u003cspan style=\"background-color: rgb(249, 250, 251);\"\u003eRed Lion Europe\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(249, 250, 251);\"\u003embCONNECT24 and mymbCONNECT24 and Helmholz myREX24 and myREX24.virtual up to and including 2.14.2 an\u0026nbsp;\u003c/span\u003eimproperly implemented access validation \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eallows an authenticated, \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003elow privileged\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;attacker to gain read access to limited, non-critical device information in his account he should not have access to.\u003c/span\u003e\n\u003c/p\u003e\n\t\t\t\t\t\u003c/div\u003e\n\t\t\t\t\u003c/div\u003e\n\t\t\t\u003c/div\u003e\n\t\t\u003c/div\u003e\n\t\n"
            }
          ],
          "value": "In Red Lion Europe\u00a0mbCONNECT24 and mymbCONNECT24 and Helmholz myREX24 and myREX24.virtual up to and including 2.14.2 an\u00a0improperly implemented access validation allows an authenticated, low privileged\u00a0attacker to gain read access to limited, non-critical device information in his account he should not have access to.\n\n\n\n\t\t\t\t\t\n\n\n\t\t\t\t\n\n\n\t\t\t\n\n\n\t\t\n\n\n\t\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-16T08:59:23.795Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2023-041"
        },
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2023-043"
        }
      ],
      "source": {
        "defect": [
          "CERT@VDE#64587"
        ],
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2023-4834",
    "datePublished": "2023-10-16T08:40:13.064Z",
    "dateReserved": "2023-09-08T07:54:38.764Z",
    "dateUpdated": "2024-09-16T18:17:07.881Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-34412 (GCVE-0-2023-34412)

Vulnerability from cvelistv5 – Published: 2023-08-17 13:07 – Updated: 2024-08-02 16:10
VLAI?
Title
Stored XXS vulnerability in mbnet, mbnet.rokey, REX 200 and REX 250
Summary
A vulnerability in Red Lion Europe mbNET/mbNET.rokey and Helmholz REX 200 and REX 250 devices with firmware lower 7.3.2 allows an authenticated remote attacker with high privileges to inject malicious HTML or JavaScript code (XSS).
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Red Lion Europe mbNET Affected: 0 , < 7.3.2 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T16:10:06.979Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2023-012/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2023-029/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbNET",
          "vendor": "Red Lion Europe",
          "versions": [
            {
              "lessThan": "7.3.2",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mbNET.rokey",
          "vendor": "Red Lion Europe",
          "versions": [
            {
              "lessThan": "7.3.2",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX 200",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "7.3.2",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "REX 250",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThan": "7.3.2",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in Red Lion Europe mbNET/mbNET.rokey and Helmholz REX 200 and REX 250 devices with firmware lower 7.3.2 allows an\nauthenticated remote attacker with high privileges to inject malicious HTML or JavaScript code (XSS)."
            }
          ],
          "value": "A vulnerability in Red Lion Europe mbNET/mbNET.rokey and Helmholz REX 200 and REX 250 devices with firmware lower 7.3.2 allows an\nauthenticated remote attacker with high privileges to inject malicious HTML or JavaScript code (XSS)."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-16T11:02:33.346Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2023-012/"
        },
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2023-029/"
        }
      ],
      "source": {
        "defect": [
          "CERT@VDE#64536"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Stored XXS vulnerability in mbnet, mbnet.rokey, REX 200 and REX 250",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2023-34412",
    "datePublished": "2023-08-17T13:07:01.697Z",
    "dateReserved": "2023-06-05T12:05:57.451Z",
    "dateUpdated": "2024-08-02T16:10:06.979Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-1779 (GCVE-0-2023-1779)

Vulnerability from cvelistv5 – Published: 2023-06-06 10:07 – Updated: 2025-01-07 19:19
VLAI?
Title
Helmholz and MB Connect Line: Account takeover via password reset in multiple products
Summary
Exposure of Sensitive Information to an unauthorized actor vulnerability in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz' myREX24 and myREX24.virtual in versions <=2.13.3 allow an authorized remote attacker with low privileges to view a limited amount of another accounts contact information.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
Impacted products
Vendor Product Version
MB Connect Line mbCONNECT24 Affected: 1.0.0 , ≤ 2.13.3 (semver)
Create a notification for this product.
    MB Connect Line mymbCONNECT24 Affected: 1.0.0 , ≤ 2.13.3 (semver)
Create a notification for this product.
    Helmholz myREX24 Affected: 0 , ≤ 2.13.3 (semver)
Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0 , ≤ 2.13.3 (semver)
Create a notification for this product.
Credits
Helmholz GmbH & Co. KG
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T05:57:25.020Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2023-008/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-1779",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-07T19:17:38.403913Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-07T19:19:11.622Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbCONNECT24",
          "vendor": "MB Connect Line",
          "versions": [
            {
              "lessThanOrEqual": "2.13.3",
              "status": "affected",
              "version": "1.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mymbCONNECT24",
          "vendor": "MB Connect Line",
          "versions": [
            {
              "lessThanOrEqual": "2.13.3",
              "status": "affected",
              "version": "1.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.13.3",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24.virtual",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.13.3",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Helmholz GmbH \u0026 Co. KG"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Exposure of Sensitive Information to an unauthorized actor vulnerability\u0026nbsp;in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz\u0027 myREX24 and myREX24.virtual in versions \u0026lt;=2.13.3 allow an authorized remote attacker with low privileges to view a limited amount of another accounts contact information."
            }
          ],
          "value": "Exposure of Sensitive Information to an unauthorized actor vulnerability\u00a0in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz\u0027 myREX24 and myREX24.virtual in versions \u003c=2.13.3 allow an authorized remote attacker with low privileges to view a limited amount of another accounts contact information."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863 Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-02T05:30:25.424Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2023-008/"
        }
      ],
      "source": {
        "advisory": "VDE-2023-002",
        "defect": [
          "CERT@VDE#64404"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Helmholz and MB Connect Line: Account takeover via password reset in multiple products",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2023-1779",
    "datePublished": "2023-06-06T10:07:35.354Z",
    "dateReserved": "2023-03-31T13:00:50.757Z",
    "dateUpdated": "2025-01-07T19:19:11.622Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-0985 (GCVE-0-2023-0985)

Vulnerability from cvelistv5 – Published: 2023-06-06 10:06 – Updated: 2025-01-07 19:20
VLAI?
Title
Helmholz and MB Connect Line: Account takeover via password reset in multiple products
Summary
An Authorization Bypass vulnerability was found in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz' myREX24 and myREX24.virtual version <= 2.13.3. An authenticated remote user with low privileges can change the password of any user in the same account. This allows to take over the admin user and therefore fully compromise the account.
CWE
  • CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
Impacted products
Vendor Product Version
MB Connect Line mbCONNECT24 Affected: 1.0.0 , ≤ 2.13.3 (semver)
Create a notification for this product.
    MB Connect Line mymbCONNECT24 Affected: 1.0.0 , ≤ 2.13.3 (semver)
Create a notification for this product.
    Helmholz myREX24 Affected: 0 , ≤ 2.13.3 (semver)
Create a notification for this product.
    Helmholz myREX24.virtual Affected: 0 , ≤ 2.13.3 (semver)
Create a notification for this product.
Credits
Hussein Alsharafi
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T05:32:45.981Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2023-002/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-0985",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-07T19:19:39.189272Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-07T19:20:21.167Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbCONNECT24",
          "vendor": "MB Connect Line",
          "versions": [
            {
              "lessThanOrEqual": "2.13.3",
              "status": "affected",
              "version": "1.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mymbCONNECT24",
          "vendor": "MB Connect Line",
          "versions": [
            {
              "lessThanOrEqual": "2.13.3",
              "status": "affected",
              "version": "1.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.13.3",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "myREX24.virtual",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.13.3",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Hussein Alsharafi"
        }
      ],
      "datePublic": "2023-05-15T10:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Authorization Bypass vulnerability was found in MB Connect Lines\u0026nbsp;mbCONNECT24, mymbCONNECT24 and Helmholz\u0027 myREX24 and myREX24.virtual version \u0026lt;= 2.13.3.\u0026nbsp;An authenticated remote user with low privileges can change the password of any user in the same account. This allows to take over the admin user and therefore fully compromise the account."
            }
          ],
          "value": "An Authorization Bypass vulnerability was found in MB Connect Lines\u00a0mbCONNECT24, mymbCONNECT24 and Helmholz\u0027 myREX24 and myREX24.virtual version \u003c= 2.13.3.\u00a0An authenticated remote user with low privileges can change the password of any user in the same account. This allows to take over the admin user and therefore fully compromise the account."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-639",
              "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-06T10:06:48.102Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2023-002/"
        }
      ],
      "source": {
        "advisory": "VDE-2023-002",
        "defect": [
          "CERT@VDE#64404"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Helmholz and MB Connect Line: Account takeover via password reset in multiple products",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2023-0985",
    "datePublished": "2023-06-06T10:06:48.102Z",
    "dateReserved": "2023-02-23T14:11:49.473Z",
    "dateUpdated": "2025-01-07T19:20:21.167Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-22520 (GCVE-0-2022-22520)

Vulnerability from cvelistv5 – Published: 2022-09-14 14:05 – Updated: 2024-09-17 04:14
VLAI?
Title
User enumeration vulnerability in MB connect line and Helmholz products
Summary
A remote, unauthenticated attacker can enumerate valid users by sending specific requests to the webservice of MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2.
CWE
  • CWE-204 - Response Discrepancy Information Exposure
Assigner
References
Impacted products
Vendor Product Version
MB connect line mymbCONNECT24 Affected: 2 , ≤ 2.11.2 (custom)
Create a notification for this product.
    MB connect line mbCONNECT24 Affected: 2 , ≤ 2.11.2 (custom)
Create a notification for this product.
    Helmholz myREX24 Affected: 2 , ≤ 2.11.2 (custom)
Create a notification for this product.
    Helmholz myREX24.virtual Affected: 2 , ≤ 2.11.2 (custom)
Create a notification for this product.
Credits
SySS GmbH reported this vulnerability to Helmholz. Helmholz reported this vulnerability to MB connect line. CERT@VDE coordinated with Helmholz & MB connect line.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.402Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2022-011"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "mymbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.11.2",
              "status": "affected",
              "version": "2",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "mbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.11.2",
              "status": "affected",
              "version": "2",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "myREX24",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.11.2",
              "status": "affected",
              "version": "2",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "myREX24.virtual",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.11.2",
              "status": "affected",
              "version": "2",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "SySS GmbH reported this vulnerability to Helmholz.  Helmholz reported this vulnerability to MB connect line. CERT@VDE coordinated with Helmholz \u0026 MB connect line."
        }
      ],
      "datePublic": "2022-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote, unauthenticated attacker can enumerate valid users by sending specific requests to the webservice of MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-204",
              "description": "CWE-204 Response Discrepancy Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-14T14:05:29",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-011"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update to Version 2.12.1"
        }
      ],
      "source": {
        "advisory": "VDE-2022-011",
        "discovery": "EXTERNAL"
      },
      "title": "User enumeration vulnerability in MB connect line and Helmholz products",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-09-07T10:00:00.000Z",
          "ID": "CVE-2022-22520",
          "STATE": "PUBLIC",
          "TITLE": "User enumeration vulnerability in MB connect line and Helmholz products"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "mymbCONNECT24",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2",
                            "version_value": "2.11.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "mbCONNECT24",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2",
                            "version_value": "2.11.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "MB connect line"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "myREX24",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2",
                            "version_value": "2.11.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "myREX24.virtual",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2",
                            "version_value": "2.11.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Helmholz"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "SySS GmbH reported this vulnerability to Helmholz.  Helmholz reported this vulnerability to MB connect line. CERT@VDE coordinated with Helmholz \u0026 MB connect line."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote, unauthenticated attacker can enumerate valid users by sending specific requests to the webservice of MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-204 Response Discrepancy Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2022-039",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
            },
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2022-011",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2022-011"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update to Version 2.12.1"
          }
        ],
        "source": {
          "advisory": "VDE-2022-011",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22520",
    "datePublished": "2022-09-14T14:05:30.024889Z",
    "dateReserved": "2022-01-03T00:00:00",
    "dateUpdated": "2024-09-17T04:14:21.926Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-34574 (GCVE-0-2021-34574)

Vulnerability from cvelistv5 – Published: 2021-08-02 10:24 – Updated: 2024-09-16 18:14
VLAI?
Title
Password policy evasion in products of MB connect line and Helmholz
Summary
In MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server.
CWE
  • CWE-669 - Incorrect Resource Transfer Between Spheres
Assigner
References
Impacted products
Vendor Product Version
MB connect line mymbCONNECT24 Affected: 2 , ≤ 2.11.2 (custom)
Create a notification for this product.
    MB connect line mbCONNECT24 Affected: 2 , ≤ 2.11.2 (custom)
Create a notification for this product.
    Helmholz myREX24 Affected: 2 , ≤ 2.11.2 (custom)
Create a notification for this product.
    Helmholz myREX24.virtual Affected: 2 , ≤ 2.11.2 (custom)
Create a notification for this product.
Credits
OTORIO reported the vulnerabilities to MB connect line.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:19:46.604Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2021-030"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "mymbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.11.2",
              "status": "affected",
              "version": "2",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "mbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.11.2",
              "status": "affected",
              "version": "2",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "myREX24",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.11.2",
              "status": "affected",
              "version": "2",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "myREX24.virtual",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.11.2",
              "status": "affected",
              "version": "2",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "OTORIO reported the vulnerabilities to MB connect line."
        }
      ],
      "datePublic": "2022-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-669",
              "description": "CWE-669 Incorrect Resource Transfer Between Spheres",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-14T14:05:29",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-030"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update to version 2.12.1"
        }
      ],
      "source": {
        "advisory": "VDE-2021-030, VDE-2022-039",
        "discovery": "EXTERNAL"
      },
      "title": "Password policy evasion in products of MB connect line and Helmholz",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-09-07T10:00:00.000Z",
          "ID": "CVE-2021-34574",
          "STATE": "PUBLIC",
          "TITLE": "Password policy evasion in products of MB connect line and Helmholz"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "mymbCONNECT24",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2",
                            "version_value": "2.11.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "mbCONNECT24",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2",
                            "version_value": "2.11.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "MB connect line"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "myREX24",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2",
                            "version_value": "2.11.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "myREX24.virtual",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2",
                            "version_value": "2.11.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Helmholz"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "OTORIO reported the vulnerabilities to MB connect line."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-669 Incorrect Resource Transfer Between Spheres"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2022-039",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
            },
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2021-030",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2021-030"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update to version 2.12.1"
          }
        ],
        "source": {
          "advisory": "VDE-2021-030, VDE-2022-039",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2021-34574",
    "datePublished": "2021-08-02T10:24:31.932350Z",
    "dateReserved": "2021-06-10T00:00:00",
    "dateUpdated": "2024-09-16T18:14:15.495Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-12527 (GCVE-0-2020-12527)

Vulnerability from cvelistv5 – Published: 2021-03-02 21:15 – Updated: 2024-09-16 20:43
VLAI?
Title
Improper Access Validation in products of MB connect line and Helmholz
Summary
An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. Improper access validation allows a logged in user to shutdown or reboot devices in his account without having corresponding permissions.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
MB connect line mymbCONNECT24 Affected: 2.6.2 , ≤ 2.11.2 (custom)
Create a notification for this product.
Credits
OTORIO reported the vulnerabilities to MB connect line. CERT@VDE coordinated.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:56:52.131Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "mymbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.11.2",
              "status": "affected",
              "version": "2.6.2",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "mbCONNECT24",
          "vendor": "MB connect line",
          "versions": [
            {
              "lessThanOrEqual": "2.11.2",
              "status": "affected",
              "version": "2.6.2",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "myREX24",
          "vendor": "Helmholz",
          "versions": [
            {
              "lessThanOrEqual": "2.11.2",
              "status": "affected",
              "version": "2",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "myREX24.virtual",
          "vendor": "Helmholz",
          "versions": [
            {
              "status": "affected",
              "version": "2.11.2"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "OTORIO reported the vulnerabilities to MB connect line. CERT@VDE coordinated."
        }
      ],
      "datePublic": "2022-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. Improper access validation allows a logged in user to shutdown or reboot devices in his account without having corresponding permissions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-16T06:10:07",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update to v2.12.1"
        }
      ],
      "source": {
        "advisory": "VDE-2021-003",
        "discovery": "EXTERNAL"
      },
      "title": "Improper Access Validation in products of MB connect line and Helmholz",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-09-07T12:50:00.000Z",
          "ID": "CVE-2020-12527",
          "STATE": "PUBLIC",
          "TITLE": "Improper Access Validation in products of MB connect line and Helmholz"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "mymbCONNECT24",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2.6.2",
                            "version_value": "2.11.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "mbCONNECT24",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2.6.2",
                            "version_value": "2.11.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "MB connect line"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "myREX24",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "2",
                            "version_value": "2.11.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "myREX24.virtual",
                      "version": {
                        "version_data": [
                          {
                            "version_name": "2",
                            "version_value": "2.11.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Helmholz"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "OTORIO reported the vulnerabilities to MB connect line. CERT@VDE coordinated."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. Improper access validation allows a logged in user to shutdown or reboot devices in his account without having corresponding permissions."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269 Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2021-003",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
            },
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2022-039",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update to v2.12.1"
          }
        ],
        "source": {
          "advisory": "VDE-2021-003",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2020-12527",
    "datePublished": "2021-03-02T21:15:24.885533Z",
    "dateReserved": "2020-04-30T00:00:00",
    "dateUpdated": "2024-09-16T20:43:07.472Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-35561 (GCVE-0-2020-35561)

Vulnerability from cvelistv5 – Published: 2021-02-16 15:49 – Updated: 2024-09-16 18:08
VLAI?
Title
SSRF in variuos products of MB connect line and Helmholz
Summary
An issue was discovered MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. There is an SSRF in the HA module allowing an unauthenticated attacker to scan for open ports.
CWE
  • n/a
Assigner
Credits
OTORIO reported the vulnerabilities to MB connect line. CERT@VDE coordinated.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T17:09:13.415Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://mbconnectline.com/security-advice/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "OTORIO reported the vulnerabilities to MB connect line. CERT@VDE coordinated."
        }
      ],
      "datePublic": "2022-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. There is an SSRF in the HA module allowing an unauthenticated attacker to scan for open ports."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-14T14:05:25",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update to 2.12.1"
        }
      ],
      "source": {
        "advisory": "VDE-2021-030, VDE-2022-039",
        "discovery": "EXTERNAL"
      },
      "title": "SSRF in variuos products of MB connect line and Helmholz",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2022-09-07T10:00:00.000Z",
          "ID": "CVE-2020-35561",
          "STATE": "PUBLIC",
          "TITLE": "SSRF in variuos products of MB connect line and Helmholz"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "OTORIO reported the vulnerabilities to MB connect line. CERT@VDE coordinated."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. There is an SSRF in the HA module allowing an unauthenticated attacker to scan for open ports."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://mbconnectline.com/security-advice/",
              "refsource": "MISC",
              "url": "https://mbconnectline.com/security-advice/"
            },
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2021-003",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
            },
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2022-039",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update to 2.12.1"
          }
        ],
        "source": {
          "advisory": "VDE-2021-030, VDE-2022-039",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-35561",
    "datePublished": "2021-02-16T15:49:45.850093Z",
    "dateReserved": "2020-12-18T00:00:00",
    "dateUpdated": "2024-09-16T18:08:12.511Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-35568 (GCVE-0-2020-35568)

Vulnerability from cvelistv5 – Published: 2021-02-16 15:44 – Updated: 2024-09-17 03:48
VLAI?
Title
Sensitive Information Exposure in products of MB connect line and Helmholz
Summary
An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. An incomplete filter applied to a database response allows an authenticated attacker to gain non-public information about other users and devices in the account.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T17:09:13.128Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://mbconnectline.com/security-advice/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2022-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. An incomplete filter applied to a database response allows an authenticated attacker to gain non-public information about other users and devices in the account."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-14T14:05:27",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update to 2.12.1"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Sensitive Information Exposure in products of MB connect line and Helmholz",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2022-09-07T10:00:00.000Z",
          "ID": "CVE-2020-35568",
          "STATE": "PUBLIC",
          "TITLE": "Sensitive Information Exposure in products of MB connect line and Helmholz"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. An incomplete filter applied to a database response allows an authenticated attacker to gain non-public information about other users and devices in the account."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://mbconnectline.com/security-advice/",
              "refsource": "MISC",
              "url": "https://mbconnectline.com/security-advice/"
            },
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2021-003",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
            },
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2022-039",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update to 2.12.1"
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-35568",
    "datePublished": "2021-02-16T15:44:10.164584Z",
    "dateReserved": "2020-12-18T00:00:00",
    "dateUpdated": "2024-09-17T03:48:34.741Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-35566 (GCVE-0-2020-35566)

Vulnerability from cvelistv5 – Published: 2021-02-16 15:40 – Updated: 2024-09-16 22:31
VLAI?
Title
Local file inclusion vulnerability in products of MB connect line and Helmholz
Summary
An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. An attacker can read arbitrary JSON files via Local File Inclusion.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T17:09:13.375Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://mbconnectline.com/security-advice/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2022-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. An attacker can read arbitrary JSON files via Local File Inclusion."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-14T14:05:26",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update to v2.12.1"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Local file inclusion vulnerability in products of MB connect line and Helmholz",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2022-09-07T10:00:00.000Z",
          "ID": "CVE-2020-35566",
          "STATE": "PUBLIC",
          "TITLE": "Local file inclusion vulnerability in products of MB connect line and Helmholz"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. An attacker can read arbitrary JSON files via Local File Inclusion."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://mbconnectline.com/security-advice/",
              "refsource": "MISC",
              "url": "https://mbconnectline.com/security-advice/"
            },
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2021-003",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
            },
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2022-039",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update to v2.12.1"
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-35566",
    "datePublished": "2021-02-16T15:40:07.656065Z",
    "dateReserved": "2020-12-18T00:00:00",
    "dateUpdated": "2024-09-16T22:31:00.471Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-35558 (GCVE-0-2020-35558)

Vulnerability from cvelistv5 – Published: 2021-02-16 15:26 – Updated: 2024-09-16 20:02
VLAI?
Title
SSRF in products of MB connect line and Helmholz
Summary
An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual through 2.11.2. There is an SSRF in the in the MySQL access check, allowing an attacker to scan for open ports and gain some information about possible credentials.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T17:09:13.403Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://mbconnectline.com/security-advice/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2022-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual through 2.11.2. There is an SSRF in the in the MySQL access check, allowing an attacker to scan for open ports and gain some information about possible credentials."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-14T14:05:24",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update to v2.12.1"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "SSRF in products of MB connect line and Helmholz",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2022-09-07T10:00:00.000Z",
          "ID": "CVE-2020-35558",
          "STATE": "PUBLIC",
          "TITLE": "SSRF in products of MB connect line and Helmholz"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual through 2.11.2. There is an SSRF in the in the MySQL access check, allowing an attacker to scan for open ports and gain some information about possible credentials."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://mbconnectline.com/security-advice/",
              "refsource": "MISC",
              "url": "https://mbconnectline.com/security-advice/"
            },
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2021-003",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
            },
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2022-039",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update to v2.12.1"
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-35558",
    "datePublished": "2021-02-16T15:26:11.394978Z",
    "dateReserved": "2020-12-18T00:00:00",
    "dateUpdated": "2024-09-16T20:02:23.622Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}