All the vulnerabilites related to siemens - scalance_xr526_firmware
Vulnerability from fkie_nvd
Published
2020-02-11 16:15
Modified
2024-11-21 04:25
Summary
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.
Impacted products
Vendor Product Version
siemens dk_standard_ethernet_controller *
siemens profinet_driver *
siemens simatic_ipc_support *
siemens ek-ertec_200_firmware *
siemens ek-ertec_200 -
siemens ek-ertec_200p_firmware *
siemens ek-ertec_200p -
siemens ruggedcom_rm1224_firmware *
siemens ruggedcom_rm1224 -
siemens scalance_m-800_firmware *
siemens scalance_m-800 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens scalance_w700_ieee_802.11n_firmware *
siemens scalance_w700_ieee_802.11n -
siemens scalance_xc-200_firmware *
siemens scalance_xc-200 -
siemens scalance_xf-200_firmware *
siemens scalance_xf-200 -
siemens scalance_xp-200_firmware *
siemens scalance_xp-200 -
siemens scalance_xb-200_firmware *
siemens scalance_xb-200 -
siemens scalance_x-200irt_firmware *
siemens scalance_x-200irt -
siemens scalance_xr-300wg_firmware *
siemens scalance_xr-300wg -
siemens scalance_x-300_firmware *
siemens scalance_x-300 -
siemens scalance_xb-200_firmware *
siemens scalance_xb-200 -
siemens scalance_xc-200_firmware *
siemens scalance_xc-200 -
siemens scalance_xp-200_firmware *
siemens scalance_xp-200 -
siemens scalance_xf-200ba_firmware *
siemens scalance_xf-200ba -
siemens scalance_xr-300wg_firmware *
siemens scalance_xr-300wg -
siemens scalance_x-400_firmware *
siemens scalance_x-400 -
siemens scalance_xm-400_firmware *
siemens scalance_xm-400 -
siemens scalance_xr524_firmware *
siemens scalance_xr524 -
siemens scalance_xr526_firmware *
siemens scalance_xr526 -
siemens scalance_xr528_firmware *
siemens scalance_xr528 -
siemens scalance_xr552_firmware *
siemens scalance_xr552 -
siemens simatic_cp_1616_firmware *
siemens simatic_cp_1616 -
siemens simatic_cp_1604_firmware *
siemens simatic_cp_1604 -
siemens simatic_cp_343-1_firmware *
siemens simatic_cp_343-1 -
siemens simatic_cp_343-1_advanced_firmware *
siemens simatic_cp_343-1_advanced -
siemens simatic_cp_343-1_erpc_firmware *
siemens simatic_cp_343-1_erpc -
siemens simatic_cp_343-1_lean_firmware *
siemens simatic_cp_343-1_lean -
siemens simatic_cp_443-1_firmware *
siemens simatic_cp_443-1 -
siemens simatic_cp_443-1_advanced_firmware *
siemens simatic_cp_443-1_advanced -
siemens simatic_cp_443-1_opc_ua_firmware *
siemens simatic_cp_443-1_opc_ua -
siemens simatic_et200al_im_157-1_pn_firmware *
siemens simatic_et200al_im_157-1_pn -
siemens simatic_et200m_im153-4_pn_io_hf_firmware *
siemens simatic_et200m_im153-4_pn_io_hf -
siemens simatic_et200m_im153-4_pn_io_st_firmware *
siemens simatic_et200m_im153-4_pn_io_st -
siemens simatic_et200mp_im155-5_pn_hf_firmware *
siemens simatic_et200mp_im155-5_pn_hf -
siemens simatic_et200mp_im155-5_pn_st_firmware *
siemens simatic_et200mp_im155-5_pn_st -
siemens simatic_et200s_firmware *
siemens simatic_et200s -
siemens simatic_et200sp_im155-6_pn_basic_firmware *
siemens simatic_et200sp_im155-6_pn_basic -
siemens simatic_et200sp_im155-6_pn_hf_firmware *
siemens simatic_et200sp_im155-6_pn_hf -
siemens simatic_et200sp_im155-6_pn_st_firmware *
siemens simatic_et200sp_im155-6_pn_st -
siemens simatic_et200ecopn_firmware *
siemens simatic_et200ecopn -
siemens simatic_et200pro_firmware *
siemens simatic_et200pro -
siemens im_154-3_pn_hf_firmware *
siemens im_154-3_pn_hf -
siemens im_154-4_pn_hf_firmware *
siemens im_154-4_pn_hf -
siemens simatic_mv440_firmware *
siemens simatic_mv440 -
siemens simatic_mv420_firmware *
siemens simatic_mv420 -
siemens simatic_pn\/pn_coupler_firmware *
siemens simatic_pn\/pn_coupler -
siemens simatic_rf180c_firmware *
siemens simatic_rf180c -
siemens simatic_rf182c_firmware *
siemens simatic_rf182c -
siemens simatic_rf600_firmware *
siemens simatic_rf600 -
siemens sinamics_dcp_firmware *
siemens sinamics_dcp -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:dk_standard_ethernet_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61011393-B517-4D6C-A048-296DD1102481",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:profinet_driver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7652A071-795B-43AF-9AAE-D2CD5A402E16",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_ipc_support:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23138553-6BE3-49C4-A620-00A005334DBB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "73529415-179F-414B-8CC5-31D3DA8A7EC0",
              "versionEndExcluding": "4.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B47CF3BB-08E4-4B86-B793-8253C172D846",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2773F4B7-095E-4A33-93F2-765FA58B828C",
              "versionEndExcluding": "4.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB75CD44-5223-40A7-A835-111BF3C25D23",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rm1224_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9CAC6A5-9968-4A29-800C-6FCD75E07E44",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rm1224:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "284DF779-D900-48B4-A177-7281CD445AB5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE353DA7-61C5-45B0-B84D-87C960F5C223",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2474D551-2605-46AA-9E53-8DD4B059E08C",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FBC29FB-270F-4F7D-9528-402EF92908FE",
              "versionEndIncluding": "6.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "880644DA-9280-4498-AD72-5CBD59CC8142",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C08F92C8-0A5D-470E-8CFC-F622C3014336",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "96432C6B-6A9E-406F-9A64-9448CB786352",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB503096-C528-478C-BD07-019C2CC882E4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3491A486-47F3-4B30-B613-DCC412F6EF5B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E673B450-C436-49F3-B2F3-872B704FE075",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "40F9AA24-B159-423F-80A0-F13D87D9C152",
              "versionEndExcluding": "5.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "94C7BE35-D3A6-488C-BB3D-D17D65DF4B80",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5CA2E13-EDD4-4B8C-AA8F-6359FFF66606",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F2C50BB-CC63-40BE-A5F0-0F0C342586CA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2D0AB50-6F0B-4232-8C8E-1647410D362D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AEB10860-FB18-4E97-B0F7-9D499DDB92C3",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D552797-8CD7-46CA-BB36-123CCFF38A2A",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79964DA8-C4E9-4E90-8D47-FE77F56E7D67",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "07322DA6-C3BA-4042-B5FB-9BF966AB3113",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5CA2E13-EDD4-4B8C-AA8F-6359FFF66606",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x-400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A511E865-88A1-4B1E-909E-291350B41F56",
              "versionEndExcluding": "6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9434103-A85B-45F1-B63B-8C596BF0DE18",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5CAA4114-E06D-4723-A04D-A5316ED1500D",
              "versionEndExcluding": "6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm-400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "798E900F-5EF9-4B39-B8C2-79FAE659E7F5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9524094D-9BF7-4A86-A939-0A8367C8B36E",
              "versionEndExcluding": "6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7DEEA300-16C3-4FEE-88A8-674DE2AEEC95",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "48AAD4D9-25C3-42B1-A36F-CA22A7FCE8F7",
              "versionEndExcluding": "6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "756A07F8-4F9F-4A76-942E-82CB92216943",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5EDC2D0B-1986-491D-9864-69C2B9EF51C1",
              "versionEndExcluding": "6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDE5E54D-FFED-4C2C-B89D-E085E61D44E4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3897836-E47F-4606-BE7A-CEB96CC24DE5",
              "versionEndExcluding": "6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AB16A0BE-5AF3-4168-B755-D023E497A35F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F08A1742-47FA-45D2-A62F-0ED5A0285486",
              "versionEndExcluding": "2.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA074FBE-1C3E-4441-8C51-52B555B85D9F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D4CB1C18-DF85-4072-8435-52AB9DD9E02E",
              "versionEndExcluding": "2.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6304FA24-F194-4EE2-95F5-35D086F82C01",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "611E1F0F-D55F-4F40-87A0-4783876182B0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C100D7C1-EAD2-455D-8A72-5BBBD85F2F77",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "794168D5-B763-42D4-9D31-55D284BFECE2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD85C545-5D9A-4A96-AFC3-5D6D645E0D5F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_erpc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "368AFAB1-3B35-41E1-9EF6-F3826181A074",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_erpc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F46730D-FD5A-42EC-8796-0702E8922E85",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3B76697-8D6F-4CBC-9333-561613CA0492",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE2A18E2-F88F-4DC1-81E9-AC836C85A248",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "88638890-5ABE-4824-A41F-FCF30532A538",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F58423D0-954E-426E-9F8F-3DD95FBDF50C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B01B39C-0039-4126-95F2-6F691C5158A0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E478FE71-32D1-4FE4-8AC9-1C898EFFD0B3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_opc_ua_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "892B0B41-2C67-4BE5-BF99-3E4840078A21",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_opc_ua:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A952EB9-11C3-4E99-895D-B101F16008BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et200al_im_157-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2CA8228-974B-4356-966E-763C30C1A916",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et200al_im_157-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A25EC630-914B-4906-8840-8B1ACBE81FEF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et200m_im153-4_pn_io_hf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "41E8BE6F-FF36-4C40-BC88-7224B0C77427",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et200m_im153-4_pn_io_hf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC1E527C-2622-43F2-8CC0-AB52EE383A2F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et200m_im153-4_pn_io_st_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34F22E8D-4CB0-4685-92C0-23DD29709BDA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et200m_im153-4_pn_io_st:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6670FFC-EF9F-429C-AECC-0677C7DAE38E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et200mp_im155-5_pn_hf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EAF506A-0F5E-414F-B6D8-50BC14C8C8CB",
              "versionEndExcluding": "4.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et200mp_im155-5_pn_hf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B26FB23-4646-4786-82B1-C24CBF9AE517",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et200mp_im155-5_pn_st_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F463025-2099-4A6C-8014-F5AAABC7D4F5",
              "versionEndExcluding": "4.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et200mp_im155-5_pn_st:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7404251E-37B7-4C70-A1E1-FB030E925487",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et200s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "09F91703-C8EE-45B1-B94F-6688D6CB4F8A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et200s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C50FF52E-3FF7-4398-9D65-9AFC9E3D30C8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_basic_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F10D55AD-37E2-49BB-8FD6-F02776507442",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn_basic:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4858340-5A05-4958-995E-4A5AF98B4848",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_hf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9B94AF1-3621-4980-89D3-390377D1DD12",
              "versionEndExcluding": "3.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn_hf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE9CBE59-18F4-40E9-A8DF-4873F8796FDA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_st_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A33CF191-ED02-4F5E-854A-EB650612D215",
              "versionEndExcluding": "4.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn_st:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F896FE89-0BCD-41F4-8F3A-4D1D09FB638C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et200ecopn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CEC2C970-9EE1-4B16-B8B1-EAAEFC1450EB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et200ecopn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5906B9AC-B5FF-493F-9956-DE2CE7570FD7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et200pro_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E0C7AB4-03DB-4E6E-86C6-E7E85D83B6B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et200pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC28C9DA-C4EA-48F6-8E6D-5375BCB1D732",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:im_154-3_pn_hf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "316A89B6-17ED-4551-9BC7-13EAAD190CA4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:im_154-3_pn_hf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C530439C-3FC8-4F2A-BFAF-F36733E4074B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:im_154-4_pn_hf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "05C95643-56B5-4A1C-8D92-A01B34E47DB0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:im_154-4_pn_hf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CB88AEB-5EAD-4B59-AD8A-4BFCEB09CE26",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_mv440_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B53B628-F96C-40B1-A952-659406759472",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_mv440:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6408042E-7E06-4AED-9853-29B176EDFE9F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_mv420_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C802EF05-03DD-4BE0-ACDA-8BDA11EA6D25",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_mv420:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "79B15C1B-2510-434B-A589-5903CA0C00EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "94587A2A-019D-4DA1-B655-35B45356F189",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49FB85F8-7D45-433E-805B-360725F2980C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf180c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "167F39FD-FFB5-4C82-BE39-0787ED369546",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf180c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "62129B85-7C98-4951-8194-2E602A8DCDBD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf182c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FC4F972-3A3B-421C-8D62-9C5C4D1992CF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf182c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7540DAD9-2AAC-46A9-B1C5-BB1AC4FCE710",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "774297C3-0A57-4902-AA98-A22ED6F4735C",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5708C3C-833E-4239-B249-CEC031F8CCC5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83803F1C-4842-43BB-B903-C2E91FF7DC08",
              "versionEndExcluding": "1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit\ninternal resource allocation when multiple legitimate diagnostic package\nrequests are sent to the DCE-RPC interface.\nThis could lead to a denial of service condition due to lack of memory\nfor devices that include a vulnerable version of the stack.\n\nThe security vulnerability could be exploited by an attacker with network\naccess to an affected device. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise the availability of the device."
    },
    {
      "lang": "es",
      "value": "Las versiones de la pila Profinet-IO (PNIO) anteriores a la V06.00 no limitan adecuadamente la asignaci\u00f3n de recursos internos cuando se env\u00edan m\u00faltiples solicitudes leg\u00edtimas de paquetes de diagn\u00f3stico a la interfaz DCE-RPC. Esto podr\u00eda conducir a una condici\u00f3n de denegaci\u00f3n de servicio debido a la falta de memoria para los dispositivos que incluyen una versi\u00f3n vulnerable de la pila. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso de red a un dispositivo afectado. La explotaci\u00f3n exitosa no requiere privilegios del sistema ni interacci\u00f3n del usuario. Un atacante podr\u00eda utilizar la vulnerabilidad para comprometer la disponibilidad del dispositivo"
    }
  ],
  "id": "CVE-2019-13946",
  "lastModified": "2024-11-21T04:25:45.080",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2020-02-11T16:15:15.023",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-780073.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-780073.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-08-10 12:15
Modified
2024-11-21 07:12
Summary
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.
Impacted products
Vendor Product Version
siemens scalance_m-800_firmware *
siemens scalance_m-800 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens scalance_sc-600_firmware *
siemens scalance_sc-600 -
siemens scalance_sc622-2c_firmware *
siemens scalance_sc622-2c -
siemens scalance_sc632-2c_firmware *
siemens scalance_sc632-2c -
siemens scalance_sc636-2c_firmware *
siemens scalance_sc636-2c -
siemens scalance_sc642-2c_firmware *
siemens scalance_sc642-2c -
siemens scalance_sc646-2c_firmware *
siemens scalance_sc646-2c -
siemens scalance_w700_ieee_802.11ax_firmware *
siemens scalance_w700_ieee_802.11ax -
siemens scalance_w700_ieee_802.11n_firmware *
siemens scalance_w700_ieee_802.11n -
siemens scalance_w700_ieee_802.11ac_firmware *
siemens scalance_w700_ieee_802.11ac -
siemens scalance_xb-200_firmware *
siemens scalance_xb-200 -
siemens scalance_xb205-3_firmware *
siemens scalance_xb205-3 -
siemens scalance_xb205-3ld_firmware *
siemens scalance_xb205-3ld -
siemens scalance_xb208_firmware *
siemens scalance_xb208 -
siemens scalance_xb213-3_firmware *
siemens scalance_xb213-3 -
siemens scalance_xb213-3ld_firmware *
siemens scalance_xb213-3ld -
siemens scalance_xb216_firmware *
siemens scalance_xb216 -
siemens scalance_xc-200_firmware *
siemens scalance_xc-200 -
siemens scalance_xc206-2_firmware *
siemens scalance_xc206-2 -
siemens scalance_xc206-2g_poe__firmware *
siemens scalance_xc206-2g_poe_ -
siemens scalance_xc206-2g_poe_eec_firmware *
siemens scalance_xc206-2g_poe_eec -
siemens scalance_xc206-2sfp_eec_firmware *
siemens scalance_xc206-2sfp_eec -
siemens scalance_xc206-2sfp_g_firmware *
siemens scalance_xc206-2sfp_g -
siemens scalance_xc206-2sfp_g_\(e\/ip\)_firmware *
siemens scalance_xc206-2sfp_g_\(e\/ip\) -
siemens scalance_xc206-2sfp_g_eec_firmware *
siemens scalance_xc206-2sfp_g_eec -
siemens scalance_xc208_firmware *
siemens scalance_xc208 -
siemens scalance_xc208eec_firmware *
siemens scalance_xc208eec -
siemens scalance_xc208g_firmware *
siemens scalance_xc208g -
siemens scalance_xc208g_\(e\/ip\)_firmware *
siemens scalance_xc208g_\(e\/ip\) -
siemens scalance_xc208g_eec_firmware *
siemens scalance_xc208g_eec -
siemens scalance_xc208g_poe_firmware *
siemens scalance_xc208g_poe -
siemens scalance_xc216_firmware *
siemens scalance_xc216 -
siemens scalance_xc216-4c_firmware *
siemens scalance_xc216-4c -
siemens scalance_xc216-4c_g_firmware *
siemens scalance_xc216-4c_g -
siemens scalance_xc216-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc216-4c_g_\(e\/ip\) -
siemens scalance_xc216-4c_g_eec_firmware *
siemens scalance_xc216-4c_g_eec -
siemens scalance_xc216eec_firmware *
siemens scalance_xc216eec -
siemens scalance_xc224__firmware *
siemens scalance_xc224_ -
siemens scalance_xc224-4c_g__firmware *
siemens scalance_xc224-4c_g_ -
siemens scalance_xc224-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc224-4c_g_\(e\/ip\) -
siemens scalance_xc224-4c_g_eec_firmware *
siemens scalance_xc224-4c_g_eec -
siemens scalance_xf-200ba_firmware *
siemens scalance_xf-200ba -
siemens scalance_xf204-2ba_dna_firmware *
siemens scalance_xf204-2ba_dna -
siemens scalance_xf204-2ba_irt_firmware *
siemens scalance_xf204-2ba_irt -
siemens scalance_xm400_firmware *
siemens scalance_xm400 -
siemens scalance_xm408-4c_firmware *
siemens scalance_xm408-4c -
siemens scalance_xm408-4c_l3_firmware *
siemens scalance_xm408-4c_l3 -
siemens scalance_xm408-8c_firmware *
siemens scalance_xm408-8c -
siemens scalance_xm408-8c_l3_firmware *
siemens scalance_xm408-8c_l3 -
siemens scalance_xm416-4c_firmware *
siemens scalance_xm416-4c -
siemens scalance_xm416-4c_l3_firmware *
siemens scalance_xm416-4c_l3 -
siemens scalance_xp-200_firmware *
siemens scalance_xp-200 -
siemens scalance_xp208_firmware *
siemens scalance_xp208 -
siemens scalance_xp208_\(eip\)_firmware *
siemens scalance_xp208_\(eip\) -
siemens scalance_xp208eec_firmware *
siemens scalance_xp208eec -
siemens scalance_xp208poe_eec_firmware *
siemens scalance_xp208poe_eec -
siemens scalance_xp216_firmware *
siemens scalance_xp216 -
siemens scalance_xp216_\(eip\)_firmware *
siemens scalance_xp216_\(eip\) -
siemens scalance_xp216eec_firmware *
siemens scalance_xp216eec -
siemens scalance_xp216poe_eec_firmware *
siemens scalance_xp216poe_eec -
siemens scalance_xr-300_firmware *
siemens scalance_xr-300 -
siemens scalance_xr-300eec_firmware *
siemens scalance_xr-300eec -
siemens scalance_xr-300poe_firmware *
siemens scalance_xr-300poe -
siemens scalance_xr-300wg_firmware *
siemens scalance_xr-300wg -
siemens scalance_xr324-12m_firmware *
siemens scalance_xr324-12m -
siemens scalance_xr324-12m_ts_firmware *
siemens scalance_xr324-12m_ts -
siemens scalance_xr324-4m_eec_firmware *
siemens scalance_xr324-4m_eec -
siemens scalance_xr324-4m_poe_firmware *
siemens scalance_xr324-4m_poe -
siemens scalance_xr324-4m_poe_ts_firmware *
siemens scalance_xr324-4m_poe_ts -
siemens scalance_xr324wg_firmware *
siemens scalance_xr324wg -
siemens scalance_xr326-2c_poe_wg_firmware *
siemens scalance_xr326-2c_poe_wg -
siemens scalance_xr328-4c_wg_firmware *
siemens scalance_xr328-4c_wg -
siemens scalance_xr500_firmware *
siemens scalance_xr500 -
siemens scalance_xr524_firmware *
siemens scalance_xr524 -
siemens scalance_xr524-8c_firmware *
siemens scalance_xr524-8c -
siemens scalance_xr524-8c_l3_firmware *
siemens scalance_xr524-8c_l3 -
siemens scalance_xr526_firmware *
siemens scalance_xr526 -
siemens scalance_xr526-8c_firmware *
siemens scalance_xr526-8c -
siemens scalance_xr526-8c_l3_firmware *
siemens scalance_xr526-8c_l3 -
siemens scalance_xr528_firmware *
siemens scalance_xr528 -
siemens scalance_xr528-6m_firmware *
siemens scalance_xr528-6m -
siemens scalance_xr528-6m_2hr2_firmware *
siemens scalance_xr528-6m_2hr2 -
siemens scalance_xr528-6m_2hr2_l3_firmware *
siemens scalance_xr528-6m_2hr2_l3 -
siemens scalance_xr528-6m_l3_firmware *
siemens scalance_xr528-6m_l3 -
siemens scalance_xr552_firmware *
siemens scalance_xr552 -
siemens scalance_xr552-12_firmware *
siemens scalance_xr552-12 -
siemens scalance_xr552-12m_firmware *
siemens scalance_xr552-12m -
siemens scalance_xr552-12m_2hr2_firmware *
siemens scalance_xr552-12m_2hr2 -
siemens scalance_xr552-12m_2hr2_l3_firmware *
siemens scalance_xr552-12m_2hr2_l3 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A43ECBDD-F831-4364-8869-C696D1AC531A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6EF65A06-2222-47D2-83B5-4C61E6D8731E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc-600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "269D399D-1B5B-46FE-A05F-90405CBC81B1",
              "versionEndExcluding": "2.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc-600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "725C671B-D7A0-48CF-8A31-5F9C4173F1DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A728A54-3FCD-46C8-89C7-D145484BF8DF",
              "versionEndExcluding": "2.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc622-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50FEE5FA-B141-4E5F-8673-363089262530",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc632-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "67B6AD24-FB63-4779-BFA0-B6849254A45C",
              "versionEndExcluding": "2.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc632-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A79836B-5EC1-40AF-8A57-9657EF6758E5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc636-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "780BDF7D-4E7F-4A45-9E7B-D261031DA24D",
              "versionEndExcluding": "2.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc636-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCB9BD17-7F1F-42E9-831F-EB907F9BC214",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc642-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F28978FB-B7F0-4D0E-9498-86F0E6B291DE",
              "versionEndExcluding": "2.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc642-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10C7D54A-27B4-4195-8131-DD5380472A75",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc646-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4CDE958F-2E63-4870-A9CD-6A0E0224B590",
              "versionEndExcluding": "2.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc646-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E54AF1E6-0E52-447C-8946-18716D30EBE2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ax_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23DDDAEC-C0B4-4E14-9840-101B6F24DBE5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ax:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "09908B6A-6655-42F0-A20B-79FFBF81937A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05D6764-79B4-4787-B2D2-E685910453C3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "880644DA-9280-4498-AD72-5CBD59CC8142",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ac_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D7CF655-D174-4CE8-A2AC-C14967A8283B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ac:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C93984BD-70E6-496C-BA20-18464B0E84B3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E673B450-C436-49F3-B2F3-872B704FE075",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8CB0BE85-4A96-45EB-9EAA-A2D9E5D45508",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9F9F101-6042-4D11-98CE-16A996023B38",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9E6A2AB-7F15-4ABB-B00A-F5667B615ABE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18DC9125-FC41-4BAB-9638-C42DEF40235B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "713ADE75-1915-4DBB-9FC3-59E9A03AB5A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C19D54A-8070-4EC6-9B30-B1B04A8BDABD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D0113244-9647-4E95-B1E4-DBD26ADD3786",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FF67A06-D93B-4E4E-A639-29E0E49654FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "692B60D5-696D-4680-BB38-3C0EC0F2D034",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D83C08F3-C6F7-46D1-B3F6-0173F9B7E983",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C08F92C8-0A5D-470E-8CFC-F622C3014336",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C93B717-35A4-4824-9B85-DB046E38DA33",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49C5CBD8-9799-4EBA-8297-EAE04F43DDD5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F02CFE9-6058-4B0D-9FD5-6C84ED4A3EAD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39310380-7D17-46C5-B91A-DFDF602D56A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4EA7C54-4200-4E33-B2EA-0F82AA3ECD9D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C21EC27-F0A8-4DCA-88AD-92D07477B5AD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B9CA045-5DB1-422C-ABE2-AC89F5A27847",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC286693-55D6-4949-8164-262EB6C022C9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "81AD4EB0-A125-4E4B-9348-AA6E670061B2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC7B235D-0141-46E5-9057-2203555AE58A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "82708B62-47F9-4909-A52C-D96BC3AA567D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB6B6ED1-7057-4240-B1C9-660173BF1A6A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "49EBEDA9-A826-45DD-A5BB-D5B55FB47B60",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F7D1CCD-4DFD-4037-9BDC-65466D639456",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "822CB559-BAFC-4674-A64B-BDCF1AAFDD0E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "316A0742-A32F-453E-922A-F084D9BEAA19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6550B2D-4B8E-414C-B4CB-7B12D6D4EA4A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "62C9A709-2AB4-4836-B925-988D78AEB278",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E922B78-7951-4115-8985-D824F6DDE41B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17E1B7ED-A272-43C6-9CA5-4CF370F8ED1C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "62852B4B-AF5A-4967-AFC2-14CEC2F6972C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1ABF1FC1-2FB5-42D8-867C-0B93AB67C096",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CCF0CEF-2E48-472E-9BDE-6E63F4CEA467",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "429647B3-1C26-42EF-94DC-B9630AA627CD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "585424EB-F9AB-45FB-B5C5-78FE45E3341A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2F04D78-74F0-4471-9AF6-54EA822F1992",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4ABC0D8D-4F32-487F-835C-DADAB647EC21",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "00C80C92-FC92-4B96-8B80-6F7E0B07EBAD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7668BC0B-A47A-4E05-9933-51CD43F3B7BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA3B23C3-8880-4640-A6B2-EA870A85AAFE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78645734-50C1-4331-9FC4-AC8A8679B6AF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2765D0D-9A77-45E5-9F58-BF877E6F94B7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "22B8B758-9781-474E-93C3-17DDDF263CC2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "09F27730-5DB8-4736-B6ED-A46C3888F48D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "323CEAEA-8122-43A5-BB87-97C7133FF510",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5A04F9F-133C-4C02-BA65-CABA47E1F329",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BE498F8-A9D8-4A92-90CE-21BA30234947",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2EA0205D-A280-4903-927A-AC4FEC051E2A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39AB9EB3-0F05-41C2-A32F-27B6D0C9C039",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFF36832-3023-4AEA-800E-ED4D87271E3A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7806CF9-4DA5-4090-84BD-D098C5FB1178",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33C3BB4B-63C9-4770-9CC0-053A0B655ED7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4E3630-DB15-46EA-B320-E4E457240B9F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9089DA8-FEF8-4927-B56A-139B67571671",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34F19168-C521-4D67-BF88-1551F079859E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6C7A93D-B629-4A56-B961-5D4FD012E6E6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FAF28152-D6CA-4D20-BDF1-1EF4B7D10429",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F316894-3BBB-4B72-8636-23868BF557AB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "99E6AFAA-B903-47BB-B0F3-7650B039C0FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6BF5436-1BCB-4945-8F2D-68F766D3567F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FC408A8-903F-43A2-9D05-65AD4482FDBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "813D5C37-C5CF-4B50-920A-38C9CF042966",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2AA81823-013F-4990-B62D-86C404F04BCB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DFCB811-4CE6-4FA9-A722-86ED0D434FD9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2FB222B-0414-4A1E-8BBD-6470CDB3BFF8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "24722F13-7DA7-4CA6-A141-293DE72B15B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7096DBA5-95BB-44D7-B7CA-B1845C87F70E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFE568ED-3604-428E-82E7-4027CB2DDD62",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78562689-B494-4500-9725-B418F1EC3CAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "616BB0A9-47FB-4F72-8241-0ADF50E6E236",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9102A41-5812-4014-BC07-E571E815ED49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "04B56011-74F9-4760-A4AD-850F0CCF0B62",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "86A2A766-9046-484F-9D49-4A1F4F0F96A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3491A486-47F3-4B30-B613-DCC412F6EF5B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54BB088B-67FC-4C34-98A0-EC05B67B2396",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24C7FB09-D247-48F0-B87C-6A478BDC0A5A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF3C7B31-25AA-4D74-AB2D-5C7F1D8025C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "17BD41C2-2398-4A03-9C5F-43AEF424261E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCFA1A9B-1130-46BC-9A5F-FFBB527517FF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B313A4C-D3E7-4964-BA51-3401546B36C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5AAC31E-42DE-423E-8F43-A5600E24160F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6E888EA-73A7-42B8-A617-621CF192F2A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D5F9D33-F74A-4FFB-9327-5CE691F0C1D6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67E4D039-5BF8-469B-A6FE-A391A6D1BDA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E0BC528-5B72-48AB-A70A-B116770A8587",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "33D044BD-12AD-42C9-B01C-957BEC6C6790",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18D7E470-D872-4C37-8669-B66328F173D6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12512EC4-FB7D-420F-9A8A-547562BE1B49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F51CE85F-16D1-4E49-83C7-70C90233E294",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B357AD42-1806-4BE5-B76D-F798E475F659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "889CF2C0-EE6C-447F-85F1-005730EAD232",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17115730-97BF-473F-A4A7-03D5AE0F1A6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FF41E9F-4627-49EE-BCF1-08B5AADE964A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300poe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18537338-DF5C-4F7A-995E-7F953B380657",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC118867-1A6C-4C3B-AD75-5D24551DB0BC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64A47C63-7150-4F8D-BFD9-2F5C2761DBDF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC751E0-FC87-4DEB-85E8-C3E028B76482",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "36C9AE74-4683-4ED0-A605-3A6B065C230E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB09860F-9DC8-476B-9AF7-6FFE57101D6C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4356417E-B4CB-45B0-B395-CE9D423FAB44",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E6AB4BE-D669-4A95-8F8A-F2DA146D5FB1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F952542-6B79-4681-A236-15C188AAEB1E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F4B8E2B-DEFF-4F1C-B5A4-0C4671C605C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "664D9C76-BC13-4874-939C-A8211DA33903",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F4DE2B7-1AB3-4BA5-B261-926B774B01DD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4834A67B-7B0B-4F88-BBFB-25667FD68EC5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "82D18854-D803-40C6-BB14-A28594C37CDB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E767C461-8FA6-4700-98CB-734AFD309140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr326-2c_poe_wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B7EC611-120E-4002-BF1E-4B45E431B7FC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr326-2c_poe_wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBD19EFB-12D2-4401-B87A-91873528E474",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFA83BBC-C6F3-4F98-A92B-2611EACBC093",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5B7DEDC-66BD-4701-BBDD-16273263ADC9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC8637DA-CA1E-46C6-AD1D-4F90B2A0BB35",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "080E722F-FCD4-4967-86EE-151ADC5702E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA8C39A2-1989-49ED-91FC-7BCE7002F250",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7DEEA300-16C3-4FEE-88A8-674DE2AEEC95",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA970560-8AE2-49B1-BCD0-E7913DEA50ED",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC7CB42C-666C-4DFD-B3CB-DD9509363E94",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1509C8A-89FC-445D-BB22-BF9A811E853B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8709D27F-90B9-4AF8-8784-E974CE859518",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "756A07F8-4F9F-4A76-942E-82CB92216943",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "554455C1-19FF-4F71-BC36-13DDE7FE0087",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "10F66ADC-91EC-4ED0-B768-03F94241B300",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0921AD23-44BA-4F5C-9DC8-A5F90753C977",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F41F6AE6-0E43-4D12-B379-FCF3A2A104DB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDE5E54D-FFED-4C2C-B89D-E085E61D44E4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0630BF0-8EFD-425A-A371-E1B0E5074D4D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DEAA4C6F-F234-4895-9D0D-B89E3F07F038",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DFEC43-5E84-460A-A50E-6BF378E83A70",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64CCA458-1F7F-44ED-ACD5-E9355B112194",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD9EACF0-ECE5-40DD-8280-41707A637E9E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B7870B9-F1CF-4503-A64C-6258FFB9D78D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81355370-BE69-434F-ABAC-8611F9909E46",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7319A333-EAA2-4ED2-A814-1AAEDFAC4E04",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AB16A0BE-5AF3-4168-B755-D023E497A35F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B490BBD4-458F-4077-8404-9208499226E7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "09743616-31C9-4E47-8A4A-B15D76204BE7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87B35693-9D07-4507-8070-43B8F756F772",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A806691-3F4B-46AA-9718-2F6BF0FD3D7A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B05DE63D-186B-46CC-B3CE-66923F290B6B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C97B2B53-F40E-4FB1-B3BA-5D0E0F8501F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF61A53B-E4AD-4379-B053-1A25FDF65BD0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA9921B1-38FD-4404-9986-3023C577FE5C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS."
    },
    {
      "lang": "es",
      "value": "Los dispositivos afectados no sanean correctamente los datos introducidos por un usuario al renderizar la interfaz web. Esto podr\u00eda permitir a un atacante remoto autenticado con privilegios administrativos inyectar c\u00f3digo y llevar a un XSS basado en el DOM"
    }
  ],
  "id": "CVE-2022-36325",
  "lastModified": "2024-11-21T07:12:47.637",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-08-10T12:15:12.997",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-80"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:22
Summary
An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 (All versions prior to v6.4).



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E40058B3-3726-4F6A-AB41-7679487639F2",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm-400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "798E900F-5EF9-4B39-B8C2-79FAE659E7F5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66B18697-4508-465B-AB56-A64DF601F8E4",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7DEEA300-16C3-4FEE-88A8-674DE2AEEC95",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1DC81BDD-1426-4BF3-AB8B-D050EC9E44EB",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "756A07F8-4F9F-4A76-942E-82CB92216943",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "70411378-1EEE-401A-A7C9-A88299215F82",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDE5E54D-FFED-4C2C-B89D-E085E61D44E4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8DA7378E-5E6A-4541-B078-AB7E8CDC0E3E",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AB16A0BE-5AF3-4168-B755-D023E497A35F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B98F706F-1994-464F-A7BC-01E476EA699F",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9102A41-5812-4014-BC07-E571E815ED49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A2826CF-A6AD-4FC8-8CE7-F1B5ACAA7451",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7096DBA5-95BB-44D7-B7CA-B1845C87F70E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "192095A3-5A69-4B45-8A01-8A563C1ED8BA",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2AA81823-013F-4990-B62D-86C404F04BCB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E34C5BF4-3761-4762-B0DE-3C4235C8B04C",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "86A2A766-9046-484F-9D49-4A1F4F0F96A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E21E3308-2C77-4233-8827-3F0613121015",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78562689-B494-4500-9725-B418F1EC3CAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "96CF5766-E762-4329-BDCC-6833CD90BC4E",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2FB222B-0414-4A1E-8BBD-6470CDB3BFF8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 (All versions prior to v6.4)."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SCALANCE XM-400 Family (todas las versiones anteriores a V6.4), SCALANCE XR-500 Family (todas las versiones anteriores a V6.4). La implementaci\u00f3n del protocolo OSPF en los dispositivos afectados maneja incorrectamente el n\u00famero de campos LSA en combinaci\u00f3n con otros campos modificados. Un atacante remoto no autenticado podr\u00eda crear una condici\u00f3n de Denegaci\u00f3n de Servicio permanente al enviar paquetes OSPF especialmente dise\u00f1ados. Una explotaci\u00f3n con \u00e9xito requiere que OSPF est\u00e9 habilitado en un dispositivo afectado"
    }
  ],
  "id": "CVE-2020-28393",
  "lastModified": "2024-11-21T05:22:42.740",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-12T14:15:11.083",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116379.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-10"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116379.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-10"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-682"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-08-10 12:15
Modified
2024-11-21 07:12
Summary
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.
Impacted products
Vendor Product Version
siemens scalance_m-800_firmware *
siemens scalance_m-800 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens scalance_sc-600_firmware *
siemens scalance_sc-600 -
siemens scalance_sc622-2c_firmware *
siemens scalance_sc622-2c -
siemens scalance_sc632-2c_firmware *
siemens scalance_sc632-2c -
siemens scalance_sc636-2c_firmware *
siemens scalance_sc636-2c -
siemens scalance_sc642-2c_firmware *
siemens scalance_sc642-2c -
siemens scalance_sc646-2c_firmware *
siemens scalance_sc646-2c -
siemens scalance_w700_ieee_802.11ax_firmware *
siemens scalance_w700_ieee_802.11ax -
siemens scalance_w700_ieee_802.11n_firmware *
siemens scalance_w700_ieee_802.11n -
siemens scalance_w700_ieee_802.11ac_firmware *
siemens scalance_w700_ieee_802.11ac -
siemens scalance_xb-200_firmware *
siemens scalance_xb-200 -
siemens scalance_xb205-3_firmware *
siemens scalance_xb205-3 -
siemens scalance_xb205-3ld_firmware *
siemens scalance_xb205-3ld -
siemens scalance_xb208_firmware *
siemens scalance_xb208 -
siemens scalance_xb213-3_firmware *
siemens scalance_xb213-3 -
siemens scalance_xb213-3ld_firmware *
siemens scalance_xb213-3ld -
siemens scalance_xb216_firmware *
siemens scalance_xb216 -
siemens scalance_xc-200_firmware *
siemens scalance_xc-200 -
siemens scalance_xc206-2_firmware *
siemens scalance_xc206-2 -
siemens scalance_xc206-2g_poe__firmware *
siemens scalance_xc206-2g_poe_ -
siemens scalance_xc206-2g_poe_eec_firmware *
siemens scalance_xc206-2g_poe_eec -
siemens scalance_xc206-2sfp_eec_firmware *
siemens scalance_xc206-2sfp_eec -
siemens scalance_xc206-2sfp_g_firmware *
siemens scalance_xc206-2sfp_g -
siemens scalance_xc206-2sfp_g_\(e\/ip\)_firmware *
siemens scalance_xc206-2sfp_g_\(e\/ip\) -
siemens scalance_xc206-2sfp_g_eec_firmware *
siemens scalance_xc206-2sfp_g_eec -
siemens scalance_xc208_firmware *
siemens scalance_xc208 -
siemens scalance_xc208eec_firmware *
siemens scalance_xc208eec -
siemens scalance_xc208g_firmware *
siemens scalance_xc208g -
siemens scalance_xc208g_\(e\/ip\)_firmware *
siemens scalance_xc208g_\(e\/ip\) -
siemens scalance_xc208g_eec_firmware *
siemens scalance_xc208g_eec -
siemens scalance_xc208g_poe_firmware *
siemens scalance_xc208g_poe -
siemens scalance_xc216_firmware *
siemens scalance_xc216 -
siemens scalance_xc216-4c_firmware *
siemens scalance_xc216-4c -
siemens scalance_xc216-4c_g_firmware *
siemens scalance_xc216-4c_g -
siemens scalance_xc216-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc216-4c_g_\(e\/ip\) -
siemens scalance_xc216-4c_g_eec_firmware *
siemens scalance_xc216-4c_g_eec -
siemens scalance_xc216eec_firmware *
siemens scalance_xc216eec -
siemens scalance_xc224__firmware *
siemens scalance_xc224_ -
siemens scalance_xc224-4c_g__firmware *
siemens scalance_xc224-4c_g_ -
siemens scalance_xc224-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc224-4c_g_\(e\/ip\) -
siemens scalance_xc224-4c_g_eec_firmware *
siemens scalance_xc224-4c_g_eec -
siemens scalance_xf-200ba_firmware *
siemens scalance_xf-200ba -
siemens scalance_xf204-2ba_dna_firmware *
siemens scalance_xf204-2ba_dna -
siemens scalance_xf204-2ba_irt_firmware *
siemens scalance_xf204-2ba_irt -
siemens scalance_xm400_firmware *
siemens scalance_xm400 -
siemens scalance_xm408-4c_firmware *
siemens scalance_xm408-4c -
siemens scalance_xm408-4c_l3_firmware *
siemens scalance_xm408-4c_l3 -
siemens scalance_xm408-8c_firmware *
siemens scalance_xm408-8c -
siemens scalance_xm408-8c_l3_firmware *
siemens scalance_xm408-8c_l3 -
siemens scalance_xm416-4c_firmware *
siemens scalance_xm416-4c -
siemens scalance_xm416-4c_l3_firmware *
siemens scalance_xm416-4c_l3 -
siemens scalance_xp-200_firmware *
siemens scalance_xp-200 -
siemens scalance_xp208_firmware *
siemens scalance_xp208 -
siemens scalance_xp208_\(eip\)_firmware *
siemens scalance_xp208_\(eip\) -
siemens scalance_xp208eec_firmware *
siemens scalance_xp208eec -
siemens scalance_xp208poe_eec_firmware *
siemens scalance_xp208poe_eec -
siemens scalance_xp216_firmware *
siemens scalance_xp216 -
siemens scalance_xp216_\(eip\)_firmware *
siemens scalance_xp216_\(eip\) -
siemens scalance_xp216eec_firmware *
siemens scalance_xp216eec -
siemens scalance_xp216poe_eec_firmware *
siemens scalance_xp216poe_eec -
siemens scalance_xr-300_firmware *
siemens scalance_xr-300 -
siemens scalance_xr-300eec_firmware *
siemens scalance_xr-300eec -
siemens scalance_xr-300poe_firmware *
siemens scalance_xr-300poe -
siemens scalance_xr-300wg_firmware *
siemens scalance_xr-300wg -
siemens scalance_xr324-12m_firmware *
siemens scalance_xr324-12m -
siemens scalance_xr324-12m_ts_firmware *
siemens scalance_xr324-12m_ts -
siemens scalance_xr324-4m_eec_firmware *
siemens scalance_xr324-4m_eec -
siemens scalance_xr324-4m_poe_firmware *
siemens scalance_xr324-4m_poe -
siemens scalance_xr324-4m_poe_ts_firmware *
siemens scalance_xr324-4m_poe_ts -
siemens scalance_xr324wg_firmware *
siemens scalance_xr324wg -
siemens scalance_xr326-2c_poe_wg_firmware *
siemens scalance_xr326-2c_poe_wg -
siemens scalance_xr328-4c_wg_firmware *
siemens scalance_xr328-4c_wg -
siemens scalance_xr500_firmware *
siemens scalance_xr500 -
siemens scalance_xr524_firmware *
siemens scalance_xr524 -
siemens scalance_xr524-8c_firmware *
siemens scalance_xr524-8c -
siemens scalance_xr524-8c_l3_firmware *
siemens scalance_xr524-8c_l3 -
siemens scalance_xr526_firmware *
siemens scalance_xr526 -
siemens scalance_xr526-8c_firmware *
siemens scalance_xr526-8c -
siemens scalance_xr526-8c_l3_firmware *
siemens scalance_xr526-8c_l3 -
siemens scalance_xr528_firmware *
siemens scalance_xr528 -
siemens scalance_xr528-6m_firmware *
siemens scalance_xr528-6m -
siemens scalance_xr528-6m_2hr2_firmware *
siemens scalance_xr528-6m_2hr2 -
siemens scalance_xr528-6m_2hr2_l3_firmware *
siemens scalance_xr528-6m_2hr2_l3 -
siemens scalance_xr528-6m_l3_firmware *
siemens scalance_xr528-6m_l3 -
siemens scalance_xr552_firmware *
siemens scalance_xr552 -
siemens scalance_xr552-12_firmware *
siemens scalance_xr552-12 -
siemens scalance_xr552-12m_firmware *
siemens scalance_xr552-12m -
siemens scalance_xr552-12m_2hr2_firmware *
siemens scalance_xr552-12m_2hr2 -
siemens scalance_xr552-12m_2hr2_l3_firmware *
siemens scalance_xr552-12m_2hr2_l3 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A43ECBDD-F831-4364-8869-C696D1AC531A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6EF65A06-2222-47D2-83B5-4C61E6D8731E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc-600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "269D399D-1B5B-46FE-A05F-90405CBC81B1",
              "versionEndExcluding": "2.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc-600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "725C671B-D7A0-48CF-8A31-5F9C4173F1DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A728A54-3FCD-46C8-89C7-D145484BF8DF",
              "versionEndExcluding": "2.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc622-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50FEE5FA-B141-4E5F-8673-363089262530",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc632-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "67B6AD24-FB63-4779-BFA0-B6849254A45C",
              "versionEndExcluding": "2.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc632-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A79836B-5EC1-40AF-8A57-9657EF6758E5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc636-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "780BDF7D-4E7F-4A45-9E7B-D261031DA24D",
              "versionEndExcluding": "2.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc636-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCB9BD17-7F1F-42E9-831F-EB907F9BC214",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc642-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F28978FB-B7F0-4D0E-9498-86F0E6B291DE",
              "versionEndExcluding": "2.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc642-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10C7D54A-27B4-4195-8131-DD5380472A75",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc646-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4CDE958F-2E63-4870-A9CD-6A0E0224B590",
              "versionEndExcluding": "2.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc646-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E54AF1E6-0E52-447C-8946-18716D30EBE2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ax_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23DDDAEC-C0B4-4E14-9840-101B6F24DBE5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ax:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "09908B6A-6655-42F0-A20B-79FFBF81937A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05D6764-79B4-4787-B2D2-E685910453C3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "880644DA-9280-4498-AD72-5CBD59CC8142",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ac_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D7CF655-D174-4CE8-A2AC-C14967A8283B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ac:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C93984BD-70E6-496C-BA20-18464B0E84B3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E673B450-C436-49F3-B2F3-872B704FE075",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8CB0BE85-4A96-45EB-9EAA-A2D9E5D45508",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9F9F101-6042-4D11-98CE-16A996023B38",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9E6A2AB-7F15-4ABB-B00A-F5667B615ABE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18DC9125-FC41-4BAB-9638-C42DEF40235B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "713ADE75-1915-4DBB-9FC3-59E9A03AB5A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C19D54A-8070-4EC6-9B30-B1B04A8BDABD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D0113244-9647-4E95-B1E4-DBD26ADD3786",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FF67A06-D93B-4E4E-A639-29E0E49654FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "692B60D5-696D-4680-BB38-3C0EC0F2D034",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D83C08F3-C6F7-46D1-B3F6-0173F9B7E983",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C08F92C8-0A5D-470E-8CFC-F622C3014336",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C93B717-35A4-4824-9B85-DB046E38DA33",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49C5CBD8-9799-4EBA-8297-EAE04F43DDD5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F02CFE9-6058-4B0D-9FD5-6C84ED4A3EAD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39310380-7D17-46C5-B91A-DFDF602D56A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4EA7C54-4200-4E33-B2EA-0F82AA3ECD9D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C21EC27-F0A8-4DCA-88AD-92D07477B5AD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B9CA045-5DB1-422C-ABE2-AC89F5A27847",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC286693-55D6-4949-8164-262EB6C022C9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "81AD4EB0-A125-4E4B-9348-AA6E670061B2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC7B235D-0141-46E5-9057-2203555AE58A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "82708B62-47F9-4909-A52C-D96BC3AA567D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB6B6ED1-7057-4240-B1C9-660173BF1A6A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "49EBEDA9-A826-45DD-A5BB-D5B55FB47B60",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F7D1CCD-4DFD-4037-9BDC-65466D639456",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "822CB559-BAFC-4674-A64B-BDCF1AAFDD0E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "316A0742-A32F-453E-922A-F084D9BEAA19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6550B2D-4B8E-414C-B4CB-7B12D6D4EA4A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "62C9A709-2AB4-4836-B925-988D78AEB278",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E922B78-7951-4115-8985-D824F6DDE41B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17E1B7ED-A272-43C6-9CA5-4CF370F8ED1C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "62852B4B-AF5A-4967-AFC2-14CEC2F6972C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1ABF1FC1-2FB5-42D8-867C-0B93AB67C096",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CCF0CEF-2E48-472E-9BDE-6E63F4CEA467",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "429647B3-1C26-42EF-94DC-B9630AA627CD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "585424EB-F9AB-45FB-B5C5-78FE45E3341A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2F04D78-74F0-4471-9AF6-54EA822F1992",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4ABC0D8D-4F32-487F-835C-DADAB647EC21",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "00C80C92-FC92-4B96-8B80-6F7E0B07EBAD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7668BC0B-A47A-4E05-9933-51CD43F3B7BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA3B23C3-8880-4640-A6B2-EA870A85AAFE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78645734-50C1-4331-9FC4-AC8A8679B6AF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2765D0D-9A77-45E5-9F58-BF877E6F94B7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "22B8B758-9781-474E-93C3-17DDDF263CC2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "09F27730-5DB8-4736-B6ED-A46C3888F48D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "323CEAEA-8122-43A5-BB87-97C7133FF510",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5A04F9F-133C-4C02-BA65-CABA47E1F329",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BE498F8-A9D8-4A92-90CE-21BA30234947",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2EA0205D-A280-4903-927A-AC4FEC051E2A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39AB9EB3-0F05-41C2-A32F-27B6D0C9C039",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFF36832-3023-4AEA-800E-ED4D87271E3A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7806CF9-4DA5-4090-84BD-D098C5FB1178",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33C3BB4B-63C9-4770-9CC0-053A0B655ED7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4E3630-DB15-46EA-B320-E4E457240B9F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9089DA8-FEF8-4927-B56A-139B67571671",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34F19168-C521-4D67-BF88-1551F079859E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6C7A93D-B629-4A56-B961-5D4FD012E6E6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FAF28152-D6CA-4D20-BDF1-1EF4B7D10429",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F316894-3BBB-4B72-8636-23868BF557AB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "99E6AFAA-B903-47BB-B0F3-7650B039C0FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6BF5436-1BCB-4945-8F2D-68F766D3567F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FC408A8-903F-43A2-9D05-65AD4482FDBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "813D5C37-C5CF-4B50-920A-38C9CF042966",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2AA81823-013F-4990-B62D-86C404F04BCB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DFCB811-4CE6-4FA9-A722-86ED0D434FD9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2FB222B-0414-4A1E-8BBD-6470CDB3BFF8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "24722F13-7DA7-4CA6-A141-293DE72B15B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7096DBA5-95BB-44D7-B7CA-B1845C87F70E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFE568ED-3604-428E-82E7-4027CB2DDD62",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78562689-B494-4500-9725-B418F1EC3CAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "616BB0A9-47FB-4F72-8241-0ADF50E6E236",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9102A41-5812-4014-BC07-E571E815ED49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "04B56011-74F9-4760-A4AD-850F0CCF0B62",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "86A2A766-9046-484F-9D49-4A1F4F0F96A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3491A486-47F3-4B30-B613-DCC412F6EF5B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54BB088B-67FC-4C34-98A0-EC05B67B2396",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24C7FB09-D247-48F0-B87C-6A478BDC0A5A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF3C7B31-25AA-4D74-AB2D-5C7F1D8025C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "17BD41C2-2398-4A03-9C5F-43AEF424261E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCFA1A9B-1130-46BC-9A5F-FFBB527517FF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B313A4C-D3E7-4964-BA51-3401546B36C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5AAC31E-42DE-423E-8F43-A5600E24160F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6E888EA-73A7-42B8-A617-621CF192F2A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D5F9D33-F74A-4FFB-9327-5CE691F0C1D6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67E4D039-5BF8-469B-A6FE-A391A6D1BDA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E0BC528-5B72-48AB-A70A-B116770A8587",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "33D044BD-12AD-42C9-B01C-957BEC6C6790",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18D7E470-D872-4C37-8669-B66328F173D6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12512EC4-FB7D-420F-9A8A-547562BE1B49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F51CE85F-16D1-4E49-83C7-70C90233E294",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B357AD42-1806-4BE5-B76D-F798E475F659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "889CF2C0-EE6C-447F-85F1-005730EAD232",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17115730-97BF-473F-A4A7-03D5AE0F1A6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FF41E9F-4627-49EE-BCF1-08B5AADE964A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300poe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18537338-DF5C-4F7A-995E-7F953B380657",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC118867-1A6C-4C3B-AD75-5D24551DB0BC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64A47C63-7150-4F8D-BFD9-2F5C2761DBDF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC751E0-FC87-4DEB-85E8-C3E028B76482",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "36C9AE74-4683-4ED0-A605-3A6B065C230E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB09860F-9DC8-476B-9AF7-6FFE57101D6C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4356417E-B4CB-45B0-B395-CE9D423FAB44",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E6AB4BE-D669-4A95-8F8A-F2DA146D5FB1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F952542-6B79-4681-A236-15C188AAEB1E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F4B8E2B-DEFF-4F1C-B5A4-0C4671C605C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "664D9C76-BC13-4874-939C-A8211DA33903",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F4DE2B7-1AB3-4BA5-B261-926B774B01DD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4834A67B-7B0B-4F88-BBFB-25667FD68EC5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "82D18854-D803-40C6-BB14-A28594C37CDB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E767C461-8FA6-4700-98CB-734AFD309140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr326-2c_poe_wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B7EC611-120E-4002-BF1E-4B45E431B7FC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr326-2c_poe_wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBD19EFB-12D2-4401-B87A-91873528E474",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFA83BBC-C6F3-4F98-A92B-2611EACBC093",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5B7DEDC-66BD-4701-BBDD-16273263ADC9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC8637DA-CA1E-46C6-AD1D-4F90B2A0BB35",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "080E722F-FCD4-4967-86EE-151ADC5702E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA8C39A2-1989-49ED-91FC-7BCE7002F250",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7DEEA300-16C3-4FEE-88A8-674DE2AEEC95",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA970560-8AE2-49B1-BCD0-E7913DEA50ED",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC7CB42C-666C-4DFD-B3CB-DD9509363E94",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1509C8A-89FC-445D-BB22-BF9A811E853B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8709D27F-90B9-4AF8-8784-E974CE859518",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "756A07F8-4F9F-4A76-942E-82CB92216943",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "554455C1-19FF-4F71-BC36-13DDE7FE0087",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "10F66ADC-91EC-4ED0-B768-03F94241B300",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0921AD23-44BA-4F5C-9DC8-A5F90753C977",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F41F6AE6-0E43-4D12-B379-FCF3A2A104DB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDE5E54D-FFED-4C2C-B89D-E085E61D44E4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0630BF0-8EFD-425A-A371-E1B0E5074D4D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DEAA4C6F-F234-4895-9D0D-B89E3F07F038",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DFEC43-5E84-460A-A50E-6BF378E83A70",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64CCA458-1F7F-44ED-ACD5-E9355B112194",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD9EACF0-ECE5-40DD-8280-41707A637E9E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B7870B9-F1CF-4503-A64C-6258FFB9D78D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81355370-BE69-434F-ABAC-8611F9909E46",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7319A333-EAA2-4ED2-A814-1AAEDFAC4E04",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AB16A0BE-5AF3-4168-B755-D023E497A35F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B490BBD4-458F-4077-8404-9208499226E7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "09743616-31C9-4E47-8A4A-B15D76204BE7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87B35693-9D07-4507-8070-43B8F756F772",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A806691-3F4B-46AA-9718-2F6BF0FD3D7A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B05DE63D-186B-46CC-B3CE-66923F290B6B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C97B2B53-F40E-4FB1-B3BA-5D0E0F8501F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF61A53B-E4AD-4379-B053-1A25FDF65BD0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA9921B1-38FD-4404-9986-3023C577FE5C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Affected devices do not properly sanitize an input field.  This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell."
    },
    {
      "lang": "es",
      "value": "Los dispositivos afectados no sanean correctamente un campo de entrada. Esto podr\u00eda permitir a un atacante remoto autenticado con privilegios administrativos inyectar c\u00f3digo o generar un shell de ra\u00edz del sistema"
    }
  ],
  "id": "CVE-2022-36323",
  "lastModified": "2024-11-21T07:12:47.000",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.3,
        "impactScore": 6.0,
        "source": "productcert@siemens.com",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-08-10T12:15:12.863",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-74"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-08-10 12:15
Modified
2024-11-21 07:12
Summary
Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.
Impacted products
Vendor Product Version
siemens scalance_m-800_firmware *
siemens scalance_m-800 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens scalance_w700_ieee_802.11ax_firmware *
siemens scalance_w700_ieee_802.11ax -
siemens scalance_w700_ieee_802.11n_firmware *
siemens scalance_w700_ieee_802.11n -
siemens scalance_w700_ieee_802.11ac_firmware *
siemens scalance_w700_ieee_802.11ac -
siemens scalance_xb-200_firmware *
siemens scalance_xb-200 -
siemens scalance_xb205-3_firmware *
siemens scalance_xb205-3 -
siemens scalance_xb205-3ld_firmware *
siemens scalance_xb205-3ld -
siemens scalance_xb208_firmware *
siemens scalance_xb208 -
siemens scalance_xb213-3_firmware *
siemens scalance_xb213-3 -
siemens scalance_xb213-3ld_firmware *
siemens scalance_xb213-3ld -
siemens scalance_xb216_firmware *
siemens scalance_xb216 -
siemens scalance_xc-200_firmware *
siemens scalance_xc-200 -
siemens scalance_xc206-2_firmware *
siemens scalance_xc206-2 -
siemens scalance_xc206-2g_poe__firmware *
siemens scalance_xc206-2g_poe_ -
siemens scalance_xc206-2g_poe_eec_firmware *
siemens scalance_xc206-2g_poe_eec -
siemens scalance_xc206-2sfp_eec_firmware *
siemens scalance_xc206-2sfp_eec -
siemens scalance_xc206-2sfp_g_firmware *
siemens scalance_xc206-2sfp_g -
siemens scalance_xc206-2sfp_g_\(e\/ip\)_firmware *
siemens scalance_xc206-2sfp_g_\(e\/ip\) -
siemens scalance_xc206-2sfp_g_eec_firmware *
siemens scalance_xc206-2sfp_g_eec -
siemens scalance_xc208_firmware *
siemens scalance_xc208 -
siemens scalance_xc208eec_firmware *
siemens scalance_xc208eec -
siemens scalance_xc208g_firmware *
siemens scalance_xc208g -
siemens scalance_xc208g_\(e\/ip\)_firmware *
siemens scalance_xc208g_\(e\/ip\) -
siemens scalance_xc208g_eec_firmware *
siemens scalance_xc208g_eec -
siemens scalance_xc208g_poe_firmware *
siemens scalance_xc208g_poe -
siemens scalance_xc216_firmware *
siemens scalance_xc216 -
siemens scalance_xc216-4c_firmware *
siemens scalance_xc216-4c -
siemens scalance_xc216-4c_g_firmware *
siemens scalance_xc216-4c_g -
siemens scalance_xc216-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc216-4c_g_\(e\/ip\) -
siemens scalance_xc216-4c_g_eec_firmware *
siemens scalance_xc216-4c_g_eec -
siemens scalance_xc216eec_firmware *
siemens scalance_xc216eec -
siemens scalance_xc224__firmware *
siemens scalance_xc224_ -
siemens scalance_xc224-4c_g__firmware *
siemens scalance_xc224-4c_g_ -
siemens scalance_xc224-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc224-4c_g_\(e\/ip\) -
siemens scalance_xc224-4c_g_eec_firmware *
siemens scalance_xc224-4c_g_eec -
siemens scalance_xf-200ba_firmware *
siemens scalance_xf-200ba -
siemens scalance_xf204-2ba_dna_firmware *
siemens scalance_xf204-2ba_dna -
siemens scalance_xf204-2ba_irt_firmware *
siemens scalance_xf204-2ba_irt -
siemens scalance_xm400_firmware *
siemens scalance_xm400 -
siemens scalance_xm408-4c_firmware *
siemens scalance_xm408-4c -
siemens scalance_xm408-4c_l3_firmware *
siemens scalance_xm408-4c_l3 -
siemens scalance_xm408-8c_firmware *
siemens scalance_xm408-8c -
siemens scalance_xm408-8c_l3_firmware *
siemens scalance_xm408-8c_l3 -
siemens scalance_xm416-4c_firmware *
siemens scalance_xm416-4c -
siemens scalance_xm416-4c_l3_firmware *
siemens scalance_xm416-4c_l3 -
siemens scalance_xp-200_firmware *
siemens scalance_xp-200 -
siemens scalance_xp208_firmware *
siemens scalance_xp208 -
siemens scalance_xp208_\(eip\)_firmware *
siemens scalance_xp208_\(eip\) -
siemens scalance_xp208eec_firmware *
siemens scalance_xp208eec -
siemens scalance_xp208poe_eec_firmware *
siemens scalance_xp208poe_eec -
siemens scalance_xp216_firmware *
siemens scalance_xp216 -
siemens scalance_xp216_\(eip\)_firmware *
siemens scalance_xp216_\(eip\) -
siemens scalance_xp216eec_firmware *
siemens scalance_xp216eec -
siemens scalance_xp216poe_eec_firmware *
siemens scalance_xp216poe_eec -
siemens scalance_xr-300_firmware *
siemens scalance_xr-300 -
siemens scalance_xr-300eec_firmware *
siemens scalance_xr-300eec -
siemens scalance_xr-300poe_firmware *
siemens scalance_xr-300poe -
siemens scalance_xr-300wg_firmware *
siemens scalance_xr-300wg -
siemens scalance_xr324-12m_firmware *
siemens scalance_xr324-12m -
siemens scalance_xr324-12m_ts_firmware *
siemens scalance_xr324-12m_ts -
siemens scalance_xr324-4m_eec_firmware *
siemens scalance_xr324-4m_eec -
siemens scalance_xr324-4m_poe_firmware *
siemens scalance_xr324-4m_poe -
siemens scalance_xr324-4m_poe_ts_firmware *
siemens scalance_xr324-4m_poe_ts -
siemens scalance_xr324wg_firmware *
siemens scalance_xr324wg -
siemens scalance_xr326-2c_poe_wg_firmware *
siemens scalance_xr326-2c_poe_wg -
siemens scalance_xr328-4c_wg_firmware *
siemens scalance_xr328-4c_wg -
siemens scalance_xr500_firmware *
siemens scalance_xr500 -
siemens scalance_xr524_firmware *
siemens scalance_xr524 -
siemens scalance_xr524-8c_firmware *
siemens scalance_xr524-8c -
siemens scalance_xr524-8c_l3_firmware *
siemens scalance_xr524-8c_l3 -
siemens scalance_xr526_firmware *
siemens scalance_xr526 -
siemens scalance_xr526-8c_firmware *
siemens scalance_xr526-8c -
siemens scalance_xr526-8c_l3_firmware *
siemens scalance_xr526-8c_l3 -
siemens scalance_xr528_firmware *
siemens scalance_xr528 -
siemens scalance_xr528-6m_firmware *
siemens scalance_xr528-6m -
siemens scalance_xr528-6m_2hr2_firmware *
siemens scalance_xr528-6m_2hr2 -
siemens scalance_xr528-6m_2hr2_l3_firmware *
siemens scalance_xr528-6m_2hr2_l3 -
siemens scalance_xr528-6m_l3_firmware *
siemens scalance_xr528-6m_l3 -
siemens scalance_xr552_firmware *
siemens scalance_xr552 -
siemens scalance_xr552-12_firmware *
siemens scalance_xr552-12 -
siemens scalance_xr552-12m_firmware *
siemens scalance_xr552-12m -
siemens scalance_xr552-12m_2hr2_firmware *
siemens scalance_xr552-12m_2hr2 -
siemens scalance_xr552-12m_2hr2_l3_firmware *
siemens scalance_xr552-12m_2hr2_l3 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A43ECBDD-F831-4364-8869-C696D1AC531A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6EF65A06-2222-47D2-83B5-4C61E6D8731E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ax_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23DDDAEC-C0B4-4E14-9840-101B6F24DBE5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ax:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "09908B6A-6655-42F0-A20B-79FFBF81937A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05D6764-79B4-4787-B2D2-E685910453C3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "880644DA-9280-4498-AD72-5CBD59CC8142",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ac_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D7CF655-D174-4CE8-A2AC-C14967A8283B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ac:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C93984BD-70E6-496C-BA20-18464B0E84B3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E673B450-C436-49F3-B2F3-872B704FE075",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8CB0BE85-4A96-45EB-9EAA-A2D9E5D45508",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9F9F101-6042-4D11-98CE-16A996023B38",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9E6A2AB-7F15-4ABB-B00A-F5667B615ABE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18DC9125-FC41-4BAB-9638-C42DEF40235B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "713ADE75-1915-4DBB-9FC3-59E9A03AB5A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C19D54A-8070-4EC6-9B30-B1B04A8BDABD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D0113244-9647-4E95-B1E4-DBD26ADD3786",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FF67A06-D93B-4E4E-A639-29E0E49654FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "692B60D5-696D-4680-BB38-3C0EC0F2D034",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D83C08F3-C6F7-46D1-B3F6-0173F9B7E983",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C08F92C8-0A5D-470E-8CFC-F622C3014336",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C93B717-35A4-4824-9B85-DB046E38DA33",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49C5CBD8-9799-4EBA-8297-EAE04F43DDD5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F02CFE9-6058-4B0D-9FD5-6C84ED4A3EAD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39310380-7D17-46C5-B91A-DFDF602D56A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4EA7C54-4200-4E33-B2EA-0F82AA3ECD9D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C21EC27-F0A8-4DCA-88AD-92D07477B5AD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B9CA045-5DB1-422C-ABE2-AC89F5A27847",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC286693-55D6-4949-8164-262EB6C022C9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "81AD4EB0-A125-4E4B-9348-AA6E670061B2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC7B235D-0141-46E5-9057-2203555AE58A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "82708B62-47F9-4909-A52C-D96BC3AA567D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB6B6ED1-7057-4240-B1C9-660173BF1A6A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "49EBEDA9-A826-45DD-A5BB-D5B55FB47B60",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F7D1CCD-4DFD-4037-9BDC-65466D639456",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "822CB559-BAFC-4674-A64B-BDCF1AAFDD0E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "316A0742-A32F-453E-922A-F084D9BEAA19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6550B2D-4B8E-414C-B4CB-7B12D6D4EA4A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "62C9A709-2AB4-4836-B925-988D78AEB278",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E922B78-7951-4115-8985-D824F6DDE41B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17E1B7ED-A272-43C6-9CA5-4CF370F8ED1C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "62852B4B-AF5A-4967-AFC2-14CEC2F6972C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1ABF1FC1-2FB5-42D8-867C-0B93AB67C096",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CCF0CEF-2E48-472E-9BDE-6E63F4CEA467",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "429647B3-1C26-42EF-94DC-B9630AA627CD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "585424EB-F9AB-45FB-B5C5-78FE45E3341A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2F04D78-74F0-4471-9AF6-54EA822F1992",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4ABC0D8D-4F32-487F-835C-DADAB647EC21",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "00C80C92-FC92-4B96-8B80-6F7E0B07EBAD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7668BC0B-A47A-4E05-9933-51CD43F3B7BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA3B23C3-8880-4640-A6B2-EA870A85AAFE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78645734-50C1-4331-9FC4-AC8A8679B6AF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2765D0D-9A77-45E5-9F58-BF877E6F94B7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "22B8B758-9781-474E-93C3-17DDDF263CC2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "09F27730-5DB8-4736-B6ED-A46C3888F48D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "323CEAEA-8122-43A5-BB87-97C7133FF510",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5A04F9F-133C-4C02-BA65-CABA47E1F329",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BE498F8-A9D8-4A92-90CE-21BA30234947",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2EA0205D-A280-4903-927A-AC4FEC051E2A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39AB9EB3-0F05-41C2-A32F-27B6D0C9C039",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFF36832-3023-4AEA-800E-ED4D87271E3A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7806CF9-4DA5-4090-84BD-D098C5FB1178",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33C3BB4B-63C9-4770-9CC0-053A0B655ED7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4E3630-DB15-46EA-B320-E4E457240B9F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9089DA8-FEF8-4927-B56A-139B67571671",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34F19168-C521-4D67-BF88-1551F079859E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6C7A93D-B629-4A56-B961-5D4FD012E6E6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FAF28152-D6CA-4D20-BDF1-1EF4B7D10429",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F316894-3BBB-4B72-8636-23868BF557AB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "99E6AFAA-B903-47BB-B0F3-7650B039C0FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6BF5436-1BCB-4945-8F2D-68F766D3567F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FC408A8-903F-43A2-9D05-65AD4482FDBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "813D5C37-C5CF-4B50-920A-38C9CF042966",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2AA81823-013F-4990-B62D-86C404F04BCB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DFCB811-4CE6-4FA9-A722-86ED0D434FD9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2FB222B-0414-4A1E-8BBD-6470CDB3BFF8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "24722F13-7DA7-4CA6-A141-293DE72B15B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7096DBA5-95BB-44D7-B7CA-B1845C87F70E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFE568ED-3604-428E-82E7-4027CB2DDD62",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78562689-B494-4500-9725-B418F1EC3CAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "616BB0A9-47FB-4F72-8241-0ADF50E6E236",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9102A41-5812-4014-BC07-E571E815ED49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "04B56011-74F9-4760-A4AD-850F0CCF0B62",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "86A2A766-9046-484F-9D49-4A1F4F0F96A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3491A486-47F3-4B30-B613-DCC412F6EF5B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54BB088B-67FC-4C34-98A0-EC05B67B2396",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24C7FB09-D247-48F0-B87C-6A478BDC0A5A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF3C7B31-25AA-4D74-AB2D-5C7F1D8025C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "17BD41C2-2398-4A03-9C5F-43AEF424261E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCFA1A9B-1130-46BC-9A5F-FFBB527517FF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B313A4C-D3E7-4964-BA51-3401546B36C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5AAC31E-42DE-423E-8F43-A5600E24160F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6E888EA-73A7-42B8-A617-621CF192F2A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D5F9D33-F74A-4FFB-9327-5CE691F0C1D6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67E4D039-5BF8-469B-A6FE-A391A6D1BDA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E0BC528-5B72-48AB-A70A-B116770A8587",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "33D044BD-12AD-42C9-B01C-957BEC6C6790",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18D7E470-D872-4C37-8669-B66328F173D6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12512EC4-FB7D-420F-9A8A-547562BE1B49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F51CE85F-16D1-4E49-83C7-70C90233E294",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B357AD42-1806-4BE5-B76D-F798E475F659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "889CF2C0-EE6C-447F-85F1-005730EAD232",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17115730-97BF-473F-A4A7-03D5AE0F1A6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FF41E9F-4627-49EE-BCF1-08B5AADE964A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300poe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18537338-DF5C-4F7A-995E-7F953B380657",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC118867-1A6C-4C3B-AD75-5D24551DB0BC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64A47C63-7150-4F8D-BFD9-2F5C2761DBDF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC751E0-FC87-4DEB-85E8-C3E028B76482",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "36C9AE74-4683-4ED0-A605-3A6B065C230E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB09860F-9DC8-476B-9AF7-6FFE57101D6C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4356417E-B4CB-45B0-B395-CE9D423FAB44",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E6AB4BE-D669-4A95-8F8A-F2DA146D5FB1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F952542-6B79-4681-A236-15C188AAEB1E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F4B8E2B-DEFF-4F1C-B5A4-0C4671C605C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "664D9C76-BC13-4874-939C-A8211DA33903",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F4DE2B7-1AB3-4BA5-B261-926B774B01DD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4834A67B-7B0B-4F88-BBFB-25667FD68EC5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "82D18854-D803-40C6-BB14-A28594C37CDB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E767C461-8FA6-4700-98CB-734AFD309140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr326-2c_poe_wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B7EC611-120E-4002-BF1E-4B45E431B7FC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr326-2c_poe_wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBD19EFB-12D2-4401-B87A-91873528E474",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFA83BBC-C6F3-4F98-A92B-2611EACBC093",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5B7DEDC-66BD-4701-BBDD-16273263ADC9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC8637DA-CA1E-46C6-AD1D-4F90B2A0BB35",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "080E722F-FCD4-4967-86EE-151ADC5702E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA8C39A2-1989-49ED-91FC-7BCE7002F250",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7DEEA300-16C3-4FEE-88A8-674DE2AEEC95",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA970560-8AE2-49B1-BCD0-E7913DEA50ED",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC7CB42C-666C-4DFD-B3CB-DD9509363E94",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1509C8A-89FC-445D-BB22-BF9A811E853B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8709D27F-90B9-4AF8-8784-E974CE859518",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "756A07F8-4F9F-4A76-942E-82CB92216943",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "554455C1-19FF-4F71-BC36-13DDE7FE0087",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "10F66ADC-91EC-4ED0-B768-03F94241B300",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0921AD23-44BA-4F5C-9DC8-A5F90753C977",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F41F6AE6-0E43-4D12-B379-FCF3A2A104DB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDE5E54D-FFED-4C2C-B89D-E085E61D44E4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0630BF0-8EFD-425A-A371-E1B0E5074D4D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DEAA4C6F-F234-4895-9D0D-B89E3F07F038",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DFEC43-5E84-460A-A50E-6BF378E83A70",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64CCA458-1F7F-44ED-ACD5-E9355B112194",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD9EACF0-ECE5-40DD-8280-41707A637E9E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B7870B9-F1CF-4503-A64C-6258FFB9D78D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81355370-BE69-434F-ABAC-8611F9909E46",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7319A333-EAA2-4ED2-A814-1AAEDFAC4E04",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AB16A0BE-5AF3-4168-B755-D023E497A35F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B490BBD4-458F-4077-8404-9208499226E7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "09743616-31C9-4E47-8A4A-B15D76204BE7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87B35693-9D07-4507-8070-43B8F756F772",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A806691-3F4B-46AA-9718-2F6BF0FD3D7A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B05DE63D-186B-46CC-B3CE-66923F290B6B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C97B2B53-F40E-4FB1-B3BA-5D0E0F8501F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF61A53B-E4AD-4379-B053-1A25FDF65BD0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2_l3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA9921B1-38FD-4404-9986-3023C577FE5C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack."
    },
    {
      "lang": "es",
      "value": "Los dispositivos afectados no manejan adecuadamente la renegociaci\u00f3n de los par\u00e1metros SSL/TLS. Esto podr\u00eda permitir a un atacante remoto no autenticado eludir la prevenci\u00f3n de fuerza bruta de TCP y provocar una condici\u00f3n de denegaci\u00f3n de servicio mientras dure el ataque"
    }
  ],
  "id": "CVE-2022-36324",
  "lastModified": "2024-11-21T07:12:47.307",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-08-10T12:15:12.930",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-770"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-770"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2019-13946
Vulnerability from cvelistv5
Published
2020-02-11 15:36
Modified
2024-08-05 00:05
Summary
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.
Impacted products
Vendor Product Version
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 Version: All Versions < V4.5
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P Version: All Versions < V4.6
Siemens PROFINET Driver for Controller Version: All Versions < V2.1
Siemens RUGGEDCOM RM1224 family Version: All versions < V4.3
Siemens SCALANCE M804PB Version: All versions < V4.3
Siemens SCALANCE M812-1 ADSL-Router Version: All versions < V4.3
Siemens SCALANCE M812-1 ADSL-Router Version: All versions < V4.3
Siemens SCALANCE M816-1 ADSL-Router Version: All versions < V4.3
Siemens SCALANCE M816-1 ADSL-Router Version: All versions < V4.3
Siemens SCALANCE M826-2 SHDSL-Router Version: All versions < V4.3
Siemens SCALANCE M874-2 Version: All versions < V4.3
Siemens SCALANCE M874-3 Version: All versions < V4.3
Siemens SCALANCE M876-3 Version: All versions < V4.3
Siemens SCALANCE M876-3 (ROK) Version: All versions < V4.3
Siemens SCALANCE M876-4 (EU) Version: All versions < V4.3
Siemens SCALANCE M876-4 (NAM) Version: All versions < V4.3
Siemens SCALANCE S615 LAN-Router Version: All versions < V4.3
Siemens SCALANCE W-700 IEEE 802.11n family Version: All versions <= V6.0.1
Siemens SCALANCE X200-4P IRT Version: All Versions < V5.3
Siemens SCALANCE X201-3P IRT Version: All Versions < V5.3
Siemens SCALANCE X201-3P IRT PRO Version: All Versions < V5.3
Siemens SCALANCE X202-2IRT Version: All Versions < V5.3
Siemens SCALANCE X202-2P IRT Version: All Versions < V5.3
Siemens SCALANCE X202-2P IRT PRO Version: All Versions < V5.3
Siemens SCALANCE X204-2 Version: All versions < V5.2.5
Siemens SCALANCE X204-2FM Version: All versions < V5.2.5
Siemens SCALANCE X204-2LD Version: All versions < V5.2.5
Siemens SCALANCE X204-2LD TS Version: All versions < V5.2.5
Siemens SCALANCE X204-2TS Version: All versions < V5.2.5
Siemens SCALANCE X204IRT Version: All Versions < V5.3
Siemens SCALANCE X204IRT PRO Version: All Versions < V5.3
Siemens SCALANCE X206-1 Version: All versions < V5.2.5
Siemens SCALANCE X206-1LD Version: All versions < V5.2.5
Siemens SCALANCE X208 Version: All versions < V5.2.5
Siemens SCALANCE X208PRO Version: All versions < V5.2.5
Siemens SCALANCE X212-2 Version: All versions < V5.2.5
Siemens SCALANCE X212-2LD Version: All versions < V5.2.5
Siemens SCALANCE X216 Version: All versions < V5.2.5
Siemens SCALANCE X224 Version: All versions < V5.2.5
Siemens SCALANCE X302-7 EEC (230V, coated) Version: All versions < V4.1.4
Siemens SCALANCE X302-7 EEC (230V) Version: All versions < V4.1.4
Siemens SCALANCE X302-7 EEC (24V, coated) Version: All versions < V4.1.4
Siemens SCALANCE X302-7 EEC (24V) Version: All versions < V4.1.4
Siemens SCALANCE X302-7 EEC (2x 230V, coated) Version: All versions < V4.1.4
Siemens SCALANCE X302-7 EEC (2x 230V) Version: All versions < V4.1.4
Siemens SCALANCE X302-7 EEC (2x 24V, coated) Version: All versions < V4.1.4
Siemens SCALANCE X302-7 EEC (2x 24V) Version: All versions < V4.1.4
Siemens SCALANCE X304-2FE Version: All versions < V4.1.4
Siemens SCALANCE X306-1LD FE Version: All versions < V4.1.4
Siemens SCALANCE X307-2 EEC (230V, coated) Version: All versions < V4.1.4
Siemens SCALANCE X307-2 EEC (230V) Version: All versions < V4.1.4
Siemens SCALANCE X307-2 EEC (24V, coated) Version: All versions < V4.1.4
Siemens SCALANCE X307-2 EEC (24V) Version: All versions < V4.1.4
Siemens SCALANCE X307-2 EEC (2x 230V, coated) Version: All versions < V4.1.4
Siemens SCALANCE X307-2 EEC (2x 230V) Version: All versions < V4.1.4
Siemens SCALANCE X307-2 EEC (2x 24V, coated) Version: All versions < V4.1.4
Siemens SCALANCE X307-2 EEC (2x 24V) Version: All versions < V4.1.4
Siemens SCALANCE X307-3 Version: All versions < V4.1.4
Siemens SCALANCE X307-3 Version: All versions < V4.1.4
Siemens SCALANCE X307-3LD Version: All versions < V4.1.4
Siemens SCALANCE X307-3LD Version: All versions < V4.1.4
Siemens SCALANCE X308-2 Version: All versions < V4.1.4
Siemens SCALANCE X308-2 Version: All versions < V4.1.4
Siemens SCALANCE X308-2LD Version: All versions < V4.1.4
Siemens SCALANCE X308-2LD Version: All versions < V4.1.4
Siemens SCALANCE X308-2LH Version: All versions < V4.1.4
Siemens SCALANCE X308-2LH Version: All versions < V4.1.4
Siemens SCALANCE X308-2LH+ Version: All versions < V4.1.4
Siemens SCALANCE X308-2LH+ Version: All versions < V4.1.4
Siemens SCALANCE X308-2M Version: All versions < V4.1.4
Siemens SCALANCE X308-2M Version: All versions < V4.1.4
Siemens SCALANCE X308-2M PoE Version: All versions < V4.1.4
Siemens SCALANCE X308-2M PoE Version: All versions < V4.1.4
Siemens SCALANCE X308-2M TS Version: All versions < V4.1.4
Siemens SCALANCE X308-2M TS Version: All versions < V4.1.4
Siemens SCALANCE X310 Version: All versions < V4.1.4
Siemens SCALANCE X310 Version: All versions < V4.1.4
Siemens SCALANCE X310FE Version: All versions < V4.1.4
Siemens SCALANCE X310FE Version: All versions < V4.1.4
Siemens SCALANCE X320-1 FE Version: All versions < V4.1.4
Siemens SCALANCE X320-1-2LD FE Version: All versions < V4.1.4
Siemens SCALANCE X408-2 Version: All versions < V4.1.4
Siemens SCALANCE XB-200 family Version: All Versions < V3.0
Siemens SCALANCE XC-200 Version: All Versions < V3.0
Siemens SCALANCE XF-200BA Version: All Versions < V3.0
Siemens SCALANCE XF201-3P IRT Version: All Versions < V5.3
Siemens SCALANCE XF202-2P IRT Version: All Versions < V5.3
Siemens SCALANCE XF204 Version: All versions < V5.2.5
Siemens SCALANCE XF204-2 Version: All versions < V5.2.5
Siemens SCALANCE XF204-2BA IRT Version: All Versions < V5.3
Siemens SCALANCE XF204IRT Version: All Versions < V5.3
Siemens SCALANCE XF206-1 Version: All versions < V5.2.5
Siemens SCALANCE XF208 Version: All versions < V5.2.5
Siemens SCALANCE XM-400 family Version: All Versions < V6.0
Siemens SCALANCE XP-200 Version: All Versions < V3.0
Siemens SCALANCE XR-300WG family Version: All Versions < V3.0
Siemens SCALANCE XR-500 family Version: All Versions < V6.0
Siemens SCALANCE XR324-12M (230V, ports on front) Version: All versions < V4.1.4
Siemens SCALANCE XR324-12M (230V, ports on front) Version: All versions < V4.1.4
Siemens SCALANCE XR324-12M (230V, ports on rear) Version: All versions < V4.1.4
Siemens SCALANCE XR324-12M (230V, ports on rear) Version: All versions < V4.1.4
Siemens SCALANCE XR324-12M (24V, ports on front) Version: All versions < V4.1.4
Siemens SCALANCE XR324-12M (24V, ports on front) Version: All versions < V4.1.4
Siemens SCALANCE XR324-12M (24V, ports on rear) Version: All versions < V4.1.4
Siemens SCALANCE XR324-12M (24V, ports on rear) Version: All versions < V4.1.4
Siemens SCALANCE XR324-12M TS (24V) Version: All versions < V4.1.4
Siemens SCALANCE XR324-12M TS (24V) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (24V, ports on front) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (24V, ports on front) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (24V, ports on rear) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (24V, ports on rear) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M PoE (230V, ports on front) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M PoE (230V, ports on rear) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M PoE (24V, ports on front) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M PoE (24V, ports on rear) Version: All versions < V4.1.4
Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) Version: All versions < V4.1.4
Siemens SIMATIC CP 1616 and CP 1604 Version: All Versions < V2.8
Siemens SIMATIC CP 343-1 Version: All versions
Siemens SIMATIC CP 343-1 Advanced Version: All versions
Siemens SIMATIC CP 343-1 ERPC Version: All versions
Siemens SIMATIC CP 343-1 Lean Version: All versions
Siemens SIMATIC CP 443-1 Version: 0   < V3.3
Siemens SIMATIC CP 443-1 Version: 0   < V3.3
Siemens SIMATIC CP 443-1 Advanced Version: 0   < V3.3
Siemens SIMATIC CP 443-1 OPC UA Version: All versions
Siemens SIMATIC ET 200AL IM 157-1 PN Version: All versions
Siemens SIMATIC ET 200M IM 153-4 PN IO HF (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC ET 200M IM 153-4 PN IO ST (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Siemens SIMATIC ET 200MP IM 155-5 PN ST Version: 0   < V4.1.0
Siemens SIMATIC ET 200pro IM 154-3 PN HF Version: 0   < *
Siemens SIMATIC ET 200pro IM 154-4 PN HF Version: All versions
Siemens SIMATIC ET 200SP IM 155-6 PN BA Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Siemens SIMATIC ET 200SP IM 155-6 PN ST Version: 0   < V4.1.0
Siemens SIMATIC ET 200SP IM 155-6 PN ST BA Version: 0   < V4.1.0
Siemens SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 4AO U/I 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN: IO-Link Master Version: All versions
Siemens SIMATIC ET200S (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC IPC Support, Package for VxWorks Version: 0   < *
Siemens SIMATIC MV420 SR-B Version: 0   < V7.0.6
Siemens SIMATIC MV420 SR-B Body Version: 0   < V7.0.6
Siemens SIMATIC MV420 SR-P Version: 0   < V7.0.6
Siemens SIMATIC MV420 SR-P Body Version: 0   < V7.0.6
Siemens SIMATIC MV440 HR Version: 0   < V7.0.6
Siemens SIMATIC MV440 SR Version: 0   < V7.0.6
Siemens SIMATIC MV440 UR Version: 0   < V7.0.6
Siemens SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) Version: All Versions
Siemens SIMATIC RF180C Version: All versions
Siemens SIMATIC RF182C Version: All versions
Siemens SIMATIC RF600R family Version: All versions < V3
Siemens SIMOTION C Version: All versions < V4.5
Siemens SIMOTION D Version: All versions < V4.5
Siemens SIMOTION P Version: All versions < V4.5
Siemens SINAMICS DCP Version: All Versions < V1.3
Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL Version: 0   < V4.2.0
Siemens SIPLUS ET 200MP IM 155-5 PN ST Version: 0   < V4.1.0
Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL Version: 0   < V4.1.0
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Version: 0   < V4.2.0
Siemens SIPLUS ET 200SP IM 155-6 PN ST Version: 0   < V4.1.0
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA Version: 0   < V4.1.0
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL Version: 0   < V4.1.0
Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL Version: 0   < V4.1.0
Siemens SIPLUS NET CP 343-1 Version: All versions
Siemens SIPLUS NET CP 343-1 Advanced Version: All versions
Siemens SIPLUS NET CP 343-1 Lean Version: All versions
Siemens SIPLUS NET CP 443-1 Version: 0   < V3.3
Siemens SIPLUS NET CP 443-1 Advanced Version: 0   < V3.3
Siemens SIPLUS NET SCALANCE X308-2 Version: All versions < V4.1.4
Siemens SOFTNET-IE PNIO Version: All versions
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2019-13946",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T18:06:01.358486Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T18:06:09.778Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:05:44.023Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-780073.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V4.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V4.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PROFINET Driver for Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W-700 IEEE 802.11n family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c= V6.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X200-4P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2FM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB-200 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC-200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF-200BA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM-400 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP-200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR-300WG family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR-500 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616 and CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V2.8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 ERPC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Lean",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200AL IM 157-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M IM 153-4 PN IO HF (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M IM 153-4 PN IO ST (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-3 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-4 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN: IO-Link Master",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200S (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC Support, Package for VxWorks",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 HR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 SR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 UR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF180C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF182C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF600R family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 343-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 343-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 343-1 Lean",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SOFTNET-IE PNIO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit\ninternal resource allocation when multiple legitimate diagnostic package\nrequests are sent to the DCE-RPC interface.\nThis could lead to a denial of service condition due to lack of memory\nfor devices that include a vulnerable version of the stack.\n\nThe security vulnerability could be exploited by an attacker with network\naccess to an affected device. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise the availability of the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T12:03:58.088Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-780073.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-13946",
    "datePublished": "2020-02-11T15:36:10",
    "dateReserved": "2019-07-18T00:00:00",
    "dateUpdated": "2024-08-05T00:05:44.023Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-28393
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-04 16:33
Severity ?
Summary
An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 (All versions prior to v6.4).
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:59.094Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-10"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116379.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE XM-400, XR-500",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to v6.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 (All versions prior to v6.4)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-682",
              "description": "INCORRECT CALCULATION CWE-682",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-13T12:00:54",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-10"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116379.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-28393",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE XM-400, XR-500",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to v6.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 (All versions prior to v6.4)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "INCORRECT CALCULATION CWE-682"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-10",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-10"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-116379.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116379.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28393",
    "datePublished": "2021-05-12T13:18:22",
    "dateReserved": "2020-11-10T00:00:00",
    "dateUpdated": "2024-08-04T16:33:59.094Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-36323
Vulnerability from cvelistv5
Published
2022-08-10 11:18
Modified
2024-08-03 10:00
Summary
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: All versions < V7.1.2
Siemens SCALANCE M804PB Version: All versions < V7.1.2
Siemens SCALANCE M812-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Siemens SCALANCE M812-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Siemens SCALANCE M816-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Siemens SCALANCE M816-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Siemens SCALANCE M826-2 SHDSL-Router Version: All versions < V7.1.2
Siemens SCALANCE M874-2 Version: All versions < V7.1.2
Siemens SCALANCE M874-3 Version: All versions < V7.1.2
Siemens SCALANCE M876-3 (EVDO) Version: All versions < V7.1.2
Siemens SCALANCE M876-3 (ROK) Version: All versions < V7.1.2
Siemens SCALANCE M876-4 (EU) Version: All versions < V7.1.2
Siemens SCALANCE M876-4 (NAM) Version: All versions < V7.1.2
Siemens SCALANCE MUM853-1 (EU) Version: All versions < V7.1.2
Siemens SCALANCE MUM856-1 (EU) Version: All versions < V7.1.2
Siemens SCALANCE MUM856-1 (RoW) Version: All versions < V7.1.2
Siemens SCALANCE S615 Version: All versions < V7.1.2
Siemens SCALANCE SC622-2C Version: All versions < V2.3.1
Siemens SCALANCE SC626-2C Version: All versions < V2.3.1
Siemens SCALANCE SC632-2C Version: All versions < V2.3.1
Siemens SCALANCE SC636-2C Version: All versions < V2.3.1
Siemens SCALANCE SC642-2C Version: All versions < V2.3.1
Siemens SCALANCE SC646-2C Version: All versions < V2.3.1
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1788-1 M12 Version: All versions
Siemens SCALANCE W1788-2 EEC M12 Version: All versions
Siemens SCALANCE W1788-2 M12 Version: All versions
Siemens SCALANCE W1788-2IA M12 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 EEC Version: All versions
Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE WAM763-1 Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (US) Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE XB205-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB208 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB208 (PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB216 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB216 (PN) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (SC) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (ST/BFOC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP EEC Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G EEC Version: All versions < V4.4
Siemens SCALANCE XC208 Version: All versions < V4.4
Siemens SCALANCE XC208EEC Version: All versions < V4.4
Siemens SCALANCE XC208G Version: All versions < V4.4
Siemens SCALANCE XC208G (EIP def.) Version: All versions < V4.4
Siemens SCALANCE XC208G EEC Version: All versions < V4.4
Siemens SCALANCE XC208G PoE Version: All versions < V4.4
Siemens SCALANCE XC208G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216 Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216-4C Version: All versions < V4.4
Siemens SCALANCE XC216-4C G Version: All versions < V4.4
Siemens SCALANCE XC216-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC216-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XC216EEC Version: All versions < V4.4
Siemens SCALANCE XC224 Version: All versions < V4.4
Siemens SCALANCE XC224-4C G Version: All versions < V4.4
Siemens SCALANCE XC224-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC224-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XF204 Version: All versions < V4.4
Siemens SCALANCE XF204 DNA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA DNA Version: All versions < V4.4
Siemens SCALANCE XM408-4C Version: All versions < V6.6
Siemens SCALANCE XM408-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM408-8C Version: All versions < V6.6
Siemens SCALANCE XM408-8C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM416-4C Version: All versions < V6.6
Siemens SCALANCE XM416-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XP208 Version: All versions < V4.4
Siemens SCALANCE XP208 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP208EEC Version: All versions < V4.4
Siemens SCALANCE XP208PoE EEC Version: All versions < V4.4
Siemens SCALANCE XP216 Version: All versions < V4.4
Siemens SCALANCE XP216 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP216EEC Version: All versions < V4.4
Siemens SCALANCE XP216POE EEC Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG (without UL) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR524-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SIPLUS NET SCALANCE XC206-2 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC208 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC216-4C Version: All versions < V4.4
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:00:04.366Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (EVDO)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices do not properly sanitize an input field.  This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-10T10:20:59.701Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-36323",
    "datePublished": "2022-08-10T11:18:33",
    "dateReserved": "2022-07-20T00:00:00",
    "dateUpdated": "2024-08-03T10:00:04.366Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-36324
Vulnerability from cvelistv5
Published
2022-08-10 11:18
Modified
2024-08-03 10:00
Summary
Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: All versions < V7.1.2
Siemens SCALANCE M804PB Version: All versions < V7.1.2
Siemens SCALANCE M812-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Siemens SCALANCE M812-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Siemens SCALANCE M816-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Siemens SCALANCE M816-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Siemens SCALANCE M826-2 SHDSL-Router Version: All versions < V7.1.2
Siemens SCALANCE M874-2 Version: All versions < V7.1.2
Siemens SCALANCE M874-3 Version: All versions < V7.1.2
Siemens SCALANCE M876-3 (EVDO) Version: All versions < V7.1.2
Siemens SCALANCE M876-3 (ROK) Version: All versions < V7.1.2
Siemens SCALANCE M876-4 (EU) Version: All versions < V7.1.2
Siemens SCALANCE M876-4 (NAM) Version: All versions < V7.1.2
Siemens SCALANCE MUM853-1 (EU) Version: All versions < V7.1.2
Siemens SCALANCE MUM856-1 (EU) Version: All versions < V7.1.2
Siemens SCALANCE MUM856-1 (RoW) Version: All versions < V7.1.2
Siemens SCALANCE S615 Version: All versions < V7.1.2
Siemens SCALANCE SC622-2C Version: All versions < V2.3.1
Siemens SCALANCE SC626-2C Version: All versions < V2.3.1
Siemens SCALANCE SC632-2C Version: All versions < V2.3.1
Siemens SCALANCE SC636-2C Version: All versions < V2.3.1
Siemens SCALANCE SC642-2C Version: All versions < V2.3.1
Siemens SCALANCE SC646-2C Version: All versions < V2.3.1
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1788-1 M12 Version: All versions
Siemens SCALANCE W1788-2 EEC M12 Version: All versions
Siemens SCALANCE W1788-2 M12 Version: All versions
Siemens SCALANCE W1788-2IA M12 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 EEC Version: All versions
Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE WAM763-1 Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (US) Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE XB205-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB208 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB208 (PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB216 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB216 (PN) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (SC) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (ST/BFOC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP EEC Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G EEC Version: All versions < V4.4
Siemens SCALANCE XC208 Version: All versions < V4.4
Siemens SCALANCE XC208EEC Version: All versions < V4.4
Siemens SCALANCE XC208G Version: All versions < V4.4
Siemens SCALANCE XC208G (EIP def.) Version: All versions < V4.4
Siemens SCALANCE XC208G EEC Version: All versions < V4.4
Siemens SCALANCE XC208G PoE Version: All versions < V4.4
Siemens SCALANCE XC208G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216 Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216-4C Version: All versions < V4.4
Siemens SCALANCE XC216-4C G Version: All versions < V4.4
Siemens SCALANCE XC216-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC216-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XC216EEC Version: All versions < V4.4
Siemens SCALANCE XC224 Version: All versions < V4.4
Siemens SCALANCE XC224-4C G Version: All versions < V4.4
Siemens SCALANCE XC224-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC224-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XF204 Version: All versions < V4.4
Siemens SCALANCE XF204 DNA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA DNA Version: All versions < V4.4
Siemens SCALANCE XM408-4C Version: All versions < V6.6
Siemens SCALANCE XM408-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM408-8C Version: All versions < V6.6
Siemens SCALANCE XM408-8C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM416-4C Version: All versions < V6.6
Siemens SCALANCE XM416-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XP208 Version: All versions < V4.4
Siemens SCALANCE XP208 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP208EEC Version: All versions < V4.4
Siemens SCALANCE XP208PoE EEC Version: All versions < V4.4
Siemens SCALANCE XP216 Version: All versions < V4.4
Siemens SCALANCE XP216 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP216EEC Version: All versions < V4.4
Siemens SCALANCE XP216POE EEC Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG (without UL) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR524-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SIPLUS NET SCALANCE XC206-2 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC208 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC216-4C Version: All versions < V4.4
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:00:04.354Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (EVDO)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-10T10:21:02.321Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-36324",
    "datePublished": "2022-08-10T11:18:39",
    "dateReserved": "2022-07-20T00:00:00",
    "dateUpdated": "2024-08-03T10:00:04.354Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-36325
Vulnerability from cvelistv5
Published
2022-08-10 11:18
Modified
2024-08-03 10:00
Summary
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: All versions < V7.1.2
Siemens SCALANCE M804PB Version: All versions < V7.1.2
Siemens SCALANCE M812-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Siemens SCALANCE M812-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Siemens SCALANCE M816-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Siemens SCALANCE M816-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Siemens SCALANCE M826-2 SHDSL-Router Version: All versions < V7.1.2
Siemens SCALANCE M874-2 Version: All versions < V7.1.2
Siemens SCALANCE M874-3 Version: All versions < V7.1.2
Siemens SCALANCE M876-3 (EVDO) Version: All versions < V7.1.2
Siemens SCALANCE M876-3 (ROK) Version: All versions < V7.1.2
Siemens SCALANCE M876-4 (EU) Version: All versions < V7.1.2
Siemens SCALANCE M876-4 (NAM) Version: All versions < V7.1.2
Siemens SCALANCE MUM853-1 (EU) Version: All versions < V7.1.2
Siemens SCALANCE MUM856-1 (EU) Version: All versions < V7.1.2
Siemens SCALANCE MUM856-1 (RoW) Version: All versions < V7.1.2
Siemens SCALANCE S615 Version: All versions < V7.1.2
Siemens SCALANCE SC622-2C Version: All versions < V2.3.1
Siemens SCALANCE SC626-2C Version: All versions < V2.3.1
Siemens SCALANCE SC632-2C Version: All versions < V2.3.1
Siemens SCALANCE SC636-2C Version: All versions < V2.3.1
Siemens SCALANCE SC642-2C Version: All versions < V2.3.1
Siemens SCALANCE SC646-2C Version: All versions < V2.3.1
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1748-1 M12 Version: All versions
Siemens SCALANCE W1788-1 M12 Version: All versions
Siemens SCALANCE W1788-2 EEC M12 Version: All versions
Siemens SCALANCE W1788-2 M12 Version: All versions
Siemens SCALANCE W1788-2IA M12 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W721-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W722-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 Version: All versions
Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W738-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 M12 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W748-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W761-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 M12 EEC Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 Version: All versions
Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 Version: All versions
Siemens SCALANCE W778-1 M12 EEC Version: All versions
Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-1 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 RJ45 Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2 SFP Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W786-2IA RJ45 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 M12 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-1 RJ45 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 M12 EEC Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE W788-2 RJ45 Version: All versions
Siemens SCALANCE WAM763-1 Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (EU) Version: All versions < V2.0
Siemens SCALANCE WAM766-1 EEC (US) Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (EU) Version: All versions < V2.0
Siemens SCALANCE WUM766-1 (US) Version: All versions < V2.0
Siemens SCALANCE XB205-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB205-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB208 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB208 (PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3 (ST, PN) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, E/IP) Version: All versions < V4.4
Siemens SCALANCE XB213-3LD (SC, PN) Version: All versions < V4.4
Siemens SCALANCE XB216 (E/IP) Version: All versions < V4.4
Siemens SCALANCE XB216 (PN) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (SC) Version: All versions < V4.4
Siemens SCALANCE XC206-2 (ST/BFOC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP EEC Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: All versions < V4.4
Siemens SCALANCE XC206-2SFP G EEC Version: All versions < V4.4
Siemens SCALANCE XC208 Version: All versions < V4.4
Siemens SCALANCE XC208EEC Version: All versions < V4.4
Siemens SCALANCE XC208G Version: All versions < V4.4
Siemens SCALANCE XC208G (EIP def.) Version: All versions < V4.4
Siemens SCALANCE XC208G EEC Version: All versions < V4.4
Siemens SCALANCE XC208G PoE Version: All versions < V4.4
Siemens SCALANCE XC208G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216 Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE Version: All versions < V4.4
Siemens SCALANCE XC216-3G PoE (54 V DC) Version: All versions < V4.4
Siemens SCALANCE XC216-4C Version: All versions < V4.4
Siemens SCALANCE XC216-4C G Version: All versions < V4.4
Siemens SCALANCE XC216-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC216-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XC216EEC Version: All versions < V4.4
Siemens SCALANCE XC224 Version: All versions < V4.4
Siemens SCALANCE XC224-4C G Version: All versions < V4.4
Siemens SCALANCE XC224-4C G (EIP Def.) Version: All versions < V4.4
Siemens SCALANCE XC224-4C G EEC Version: All versions < V4.4
Siemens SCALANCE XF204 Version: All versions < V4.4
Siemens SCALANCE XF204 DNA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA Version: All versions < V4.4
Siemens SCALANCE XF204-2BA DNA Version: All versions < V4.4
Siemens SCALANCE XM408-4C Version: All versions < V6.6
Siemens SCALANCE XM408-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM408-8C Version: All versions < V6.6
Siemens SCALANCE XM408-8C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XM416-4C Version: All versions < V6.6
Siemens SCALANCE XM416-4C (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XP208 Version: All versions < V4.4
Siemens SCALANCE XP208 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP208EEC Version: All versions < V4.4
Siemens SCALANCE XP208PoE EEC Version: All versions < V4.4
Siemens SCALANCE XP216 Version: All versions < V4.4
Siemens SCALANCE XP216 (Ethernet/IP) Version: All versions < V4.4
Siemens SCALANCE XP216EEC Version: All versions < V4.4
Siemens SCALANCE XP216POE EEC Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG Version: All versions < V4.4
Siemens SCALANCE XR326-2C PoE WG (without UL) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: All versions < V4.4
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: All versions < V4.4
Siemens SCALANCE XR524-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V Version: All versions < V6.6
Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR528-6M (L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Siemens SIPLUS NET SCALANCE XC206-2 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC206-2SFP Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC208 Version: All versions < V4.4
Siemens SIPLUS NET SCALANCE XC216-4C Version: All versions < V4.4
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:00:04.293Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (EVDO)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.1.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-10T10:21:04.880Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-36325",
    "datePublished": "2022-08-10T11:18:45",
    "dateReserved": "2022-07-20T00:00:00",
    "dateUpdated": "2024-08-03T10:00:04.293Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",