Vulnerabilites related to siemens - simatic_hmi_ktp_mobile_panels_ktp700_firmware
CVE-2019-6575 (GCVE-0-2019-6575)
Vulnerability from cvelistv5
Published
2019-04-17 13:40
Modified
2024-08-04 20:23
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf | x_refsource_MISC |
Impacted products
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-04T20:23:22.041Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC CP 443-1 OPC UA", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.7", }, ], }, { product: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Upd 4", }, ], }, { product: "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Upd 4", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Upd 4", }, ], }, { product: "SIMATIC IPC DiagMonitor", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V5.1.3", }, ], }, { product: "SIMATIC NET PC Software V13", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SIMATIC NET PC Software V14", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V14 SP1 Update 14", }, ], }, { product: "SIMATIC NET PC Software V15", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SIMATIC RF188C", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.1.0", }, ], }, { product: "SIMATIC RF600R family", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.1", }, ], }, { product: "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions >= V2.5 < V2.6.1", }, ], }, { product: "SIMATIC S7-1500 Software Controller", vendor: "Siemens", versions: [ { status: "affected", version: "All versions between V2.5 (including) and V2.7 (excluding)", }, ], }, { product: "SIMATIC WinCC OA", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.15 P018", }, ], }, { product: "SIMATIC WinCC Runtime Advanced", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Upd 4", }, ], }, { product: "SINEC NMS", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.0 SP1", }, ], }, { product: "SINEMA Server", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V14 SP2", }, ], }, { product: "SINUMERIK OPC UA Server", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1", }, ], }, { product: "TeleControl Server Basic", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.1.1", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-248", description: "CWE-248: Uncaught Exception", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2022-08-10T11:16:36", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2019-6575", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC CP 443-1 OPC UA", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V2.7", }, ], }, }, { product_name: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Upd 4", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Upd 4", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F", version: { version_data: [ { version_value: "All versions < V15.1 Upd 4", }, ], }, }, { product_name: "SIMATIC IPC DiagMonitor", version: { version_data: [ { version_value: "All versions < V5.1.3", }, ], }, }, { product_name: "SIMATIC NET PC Software V13", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SIMATIC NET PC Software V14", version: { version_data: [ { version_value: "All versions < V14 SP1 Update 14", }, ], }, }, { product_name: "SIMATIC NET PC Software V15", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SIMATIC RF188C", version: { version_data: [ { version_value: "All versions < V1.1.0", }, ], }, }, { product_name: "SIMATIC RF600R family", version: { version_data: [ { version_value: "All versions < V3.2.1", }, ], }, }, { product_name: "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", version: { version_data: [ { version_value: "All versions >= V2.5 < V2.6.1", }, ], }, }, { product_name: "SIMATIC S7-1500 Software Controller", version: { version_data: [ { version_value: "All versions between V2.5 (including) and V2.7 (excluding)", }, ], }, }, { product_name: "SIMATIC WinCC OA", version: { version_data: [ { version_value: "All versions < V3.15 P018", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced", version: { version_data: [ { version_value: "All versions < V15.1 Upd 4", }, ], }, }, { product_name: "SINEC NMS", version: { version_data: [ { version_value: "All versions < V1.0 SP1", }, ], }, }, { product_name: "SINEMA Server", version: { version_data: [ { version_value: "All versions < V14 SP2", }, ], }, }, { product_name: "SINUMERIK OPC UA Server", version: { version_data: [ { version_value: "All versions < V2.1", }, ], }, }, { product_name: "TeleControl Server Basic", version: { version_data: [ { version_value: "All versions < V3.1.1", }, ], }, }, ], }, vendor_name: "Siemens", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-248: Uncaught Exception", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2019-6575", datePublished: "2019-04-17T13:40:24", dateReserved: "2019-01-22T00:00:00", dateUpdated: "2024-08-04T20:23:22.041Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2021-27383 (GCVE-0-2021-27383)
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T20:48:16.589Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC WinCC Runtime Advanced V15", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC WinCC Runtime Advanced V16", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SINAMICS GH150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS GL150 (with option X30)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS GM150 (with option X30)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SH150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SL150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SM120", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SM150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SM150i", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-770", description: "CWE-770: Allocation of Resources Without Limits or Throttling", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2021-10-12T09:49:15", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { tags: [ "x_refsource_MISC", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2021-27383", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced V15", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced V16", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SINAMICS GH150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS GL150 (with option X30)", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS GM150 (with option X30)", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SH150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SL150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SM120", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SM150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SM150i", version: { version_data: [ { version_value: "All versions", }, ], }, }, ], }, vendor_name: "Siemens", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-770: Allocation of Resources Without Limits or Throttling", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { name: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", refsource: "MISC", url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2021-27383", datePublished: "2021-05-12T13:18:22", dateReserved: "2021-02-18T00:00:00", dateUpdated: "2024-08-03T20:48:16.589Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2018-13812 (GCVE-0-2018-13812)
Vulnerability from cvelistv5
Published
2018-12-13 16:00
Modified
2024-08-05 09:14
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
http://www.securityfocus.com/bid/105922 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens AG | SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) |
Version: SIMATIC HMI Comfort Panels 4" - 22" : All versions < V15 Update 4 Version: SIMATIC HMI Comfort Outdoor Panels 7" & 15" : All versions < V15 Update 4 Version: SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V15 Update 4 Version: SIMATIC WinCC Runtime Advanced : All versions < V15 Update 4 Version: SIMATIC WinCC Runtime Professional : All versions < V15 Update 4 Version: SIMATIC WinCC (TIA Portal) : All versions < V15 Update 4 Version: SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions |
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-05T09:14:47.285Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { name: "105922", tags: [ "vdb-entry", "x_refsource_BID", "x_transferred", ], url: "http://www.securityfocus.com/bid/105922", }, { tags: [ "x_refsource_CONFIRM", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" & 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", vendor: "Siemens AG", versions: [ { status: "affected", version: "SIMATIC HMI Comfort Panels 4\" - 22\" : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC WinCC Runtime Advanced : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC WinCC Runtime Professional : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC WinCC (TIA Portal) : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions", }, ], }, ], datePublic: "2018-12-13T00:00:00", descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-22", description: "CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2018-12-14T10:57:02", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { name: "105922", tags: [ "vdb-entry", "x_refsource_BID", ], url: "http://www.securityfocus.com/bid/105922", }, { tags: [ "x_refsource_CONFIRM", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2018-13812", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" & 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", version: { version_data: [ { version_value: "SIMATIC HMI Comfort Panels 4\" - 22\" : All versions < V15 Update 4", }, { version_value: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" : All versions < V15 Update 4", }, { version_value: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V15 Update 4", }, { version_value: "SIMATIC WinCC Runtime Advanced : All versions < V15 Update 4", }, { version_value: "SIMATIC WinCC Runtime Professional : All versions < V15 Update 4", }, { version_value: "SIMATIC WinCC (TIA Portal) : All versions < V15 Update 4", }, { version_value: "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions", }, ], }, }, ], }, vendor_name: "Siemens AG", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')", }, ], }, ], }, references: { reference_data: [ { name: "105922", refsource: "BID", url: "http://www.securityfocus.com/bid/105922", }, { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", refsource: "CONFIRM", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2018-13812", datePublished: "2018-12-13T16:00:00", dateReserved: "2018-07-10T00:00:00", dateUpdated: "2024-08-05T09:14:47.285Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2019-6576 (GCVE-0-2019-6576)
Vulnerability from cvelistv5
Published
2019-05-14 19:54
Modified
2024-08-04 20:23
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf | x_refsource_MISC | |
http://www.securityfocus.com/bid/108412 | vdb-entry, x_refsource_BID | |
https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens AG | SIMATIC HMI Comfort Panels 4" - 22" |
Version: All versions < V15.1 Update 1 |
|||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-04T20:23:22.141Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { name: "108412", tags: [ "vdb-entry", "x_refsource_BID", "x_transferred", ], url: "http://www.securityfocus.com/bid/108412", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC HMI Comfort Panels 4\" - 22\"", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\"", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC WinCC Runtime Advanced", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC WinCC Runtime Professional", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC WinCC (TIA Portal)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-310", description: "CWE-310: Cryptographic Issues", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2019-10-24T15:26:04", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { name: "108412", tags: [ "vdb-entry", "x_refsource_BID", ], url: "http://www.securityfocus.com/bid/108412", }, { tags: [ "x_refsource_MISC", ], url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2019-6576", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC HMI Comfort Panels 4\" - 22\"", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\"", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Professional", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC WinCC (TIA Portal)", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", version: { version_data: [ { version_value: "All versions", }, ], }, }, ], }, vendor_name: "Siemens AG", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-310: Cryptographic Issues", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { name: "108412", refsource: "BID", url: "http://www.securityfocus.com/bid/108412", }, { name: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", refsource: "MISC", url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2019-6576", datePublished: "2019-05-14T19:54:48", dateReserved: "2019-01-22T00:00:00", dateUpdated: "2024-08-04T20:23:22.141Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2021-25662 (GCVE-0-2021-25662)
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:11
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T20:11:27.535Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC WinCC Runtime Advanced V15", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC WinCC Runtime Advanced V16", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-755", description: "CWE-755: Improper Handling of Exceptional Conditions", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2021-10-12T09:49:14", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { tags: [ "x_refsource_MISC", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2021-25662", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced V15", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced V16", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, ], }, vendor_name: "Siemens", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-755: Improper Handling of Exceptional Conditions", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { name: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", refsource: "MISC", url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2021-25662", datePublished: "2021-05-12T13:18:22", dateReserved: "2021-01-21T00:00:00", dateUpdated: "2024-08-03T20:11:27.535Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2019-6568 (GCVE-0-2019-6568)
Vulnerability from cvelistv5
Published
2019-04-17 13:40
Modified
2024-08-04 20:23
Severity ?
EPSS score ?
Summary
The webserver of the affected devices contains a vulnerability that may lead to
a denial of service condition. An attacker may cause a denial of service
situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network
access to the affected systems. Successful exploitation requires no system
privileges and no user interaction. An attacker could use the vulnerability
to compromise availability of the device.
References
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1604 |
Version: All versions |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-04T20:23:22.207Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf", }, { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { defaultStatus: "unknown", product: "SIMATIC CP 1604", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 1616", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 343-1 Advanced", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1 Advanced", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC CP 443-1 OPC UA", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM154-8 PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM154-8F PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200pro IM154-8FX PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200S IM151-8 PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200S IM151-8F PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1.6", }, ], }, { defaultStatus: "unknown", product: "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.7", }, ], }, { defaultStatus: "unknown", product: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Upd4", }, ], }, { defaultStatus: "unknown", product: "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Upd4", }, ], }, { defaultStatus: "unknown", product: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Upd4", }, ], }, { defaultStatus: "unknown", product: "SIMATIC IPC DiagMonitor", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V5.1.3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF182C", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF185C", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.1.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF186C", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.1.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF188C", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.1.0", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF600R family", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RFID 181EIP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.6.1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-1500 Software Controller", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.7", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 314C-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.3.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 315-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 315F-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 315T-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 317-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 317F-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 317T-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 317TF-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 319-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-300 CPU 319F-3 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC S7-PLCSIM Advanced", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.0 SP1 UPD1", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Teleservice Adapter IE Advanced", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Teleservice Adapter IE Basic", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Teleservice Adapter IE Standard", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIMATIC WinAC RTX 2010", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2010 SP3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC WinAC RTX F 2010", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2010 SP3", }, ], }, { defaultStatus: "unknown", product: "SIMATIC WinCC Runtime Advanced", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Upd4", }, ], }, { defaultStatus: "unknown", product: "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.1.3", }, ], }, { defaultStatus: "unknown", product: "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1.3", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G130 V4.6 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G130 V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G130 V4.7 SP1 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G130 V4.8 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 HF6", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G130 V5.1 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G130 V5.1 SP1 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V5.1 SP1 HF4", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G150 V4.6 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G150 V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G150 V4.7 SP1 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G150 V4.8 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 HF6", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G150 V5.1 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS G150 V5.1 SP1 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V5.1 SP1 HF4", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GH150 V4.7 (Control Unit)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GH150 V4.8 (Control Unit)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 SP2 HF9", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GL150 V4.7 (Control Unit)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GL150 V4.8 (Control Unit)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 SP2 HF9", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GM150 V4.7 (Control Unit)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS GM150 V4.8 (Control Unit)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 SP2 HF9", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 HF6", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V5.1 SP1 HF4", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S150 V4.6 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S150 V4.7 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S150 V4.7 SP1 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S150 V4.8 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 HF6", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S150 V5.1 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S150 V5.1 SP1 Control Unit", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V5.1 SP1 HF4", }, ], }, { defaultStatus: "unknown", product: "SINAMICS S210", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V5.1 SP1 HF8", }, ], }, { defaultStatus: "unknown", product: "SINAMICS SL150 V4.7 (Control Unit)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.7 HF33", }, ], }, { defaultStatus: "unknown", product: "SINAMICS SL150 V4.8 (Control Unit)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS SM120 V4.7 (Control Unit)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SINAMICS SM120 V4.8 (Control Unit)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.8 SP2 HF10", }, ], }, { defaultStatus: "unknown", product: "SINAMICS SM150 V4.8 (Control Unit)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200S IM151-8 PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIPLUS ET 200S IM151-8F PN/DP CPU", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIPLUS NET CP 343-1 Advanced", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { defaultStatus: "unknown", product: "SIPLUS NET CP 443-1", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.3", }, ], }, { defaultStatus: "unknown", product: "SIPLUS NET CP 443-1 Advanced", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.3", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 314C-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.3.16", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 315-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 315F-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 317-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SIPLUS S7-300 CPU 317F-2 PN/DP", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V3.2.16", }, ], }, { defaultStatus: "unknown", product: "SITOP Manager", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.1", }, ], }, { defaultStatus: "unknown", product: "SITOP PSU8600", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V1.5", }, ], }, { defaultStatus: "unknown", product: "SITOP UPS1600 (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.3", }, ], }, { defaultStatus: "unknown", product: "TIM 1531 IRC (incl. SIPLUS NET variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V2.1", }, ], }, ], descriptions: [ { lang: "en", value: "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device.", }, ], metrics: [ { cvssV3_1: { baseScore: 7.5, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", version: "3.1", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-125", description: "CWE-125: Out-of-bounds Read", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2023-05-09T11:51:03.049Z", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { url: "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf", }, { url: "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf", }, ], }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2019-6568", datePublished: "2019-04-17T13:40:24", dateReserved: "2019-01-22T00:00:00", dateUpdated: "2024-08-04T20:23:22.207Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2021-25660 (GCVE-0-2021-25660)
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:11
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T20:11:27.734Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC WinCC Runtime Advanced V15", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC WinCC Runtime Advanced V16", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-788", description: "CWE-788: Access of Memory Location After End of Buffer", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2021-10-12T09:49:11", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2021-25660", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced V15", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced V16", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, ], }, vendor_name: "Siemens", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-788: Access of Memory Location After End of Buffer", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2021-25660", datePublished: "2021-05-12T13:18:22", dateReserved: "2021-01-21T00:00:00", dateUpdated: "2024-08-03T20:11:27.734Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2021-27386 (GCVE-0-2021-27386)
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T20:48:16.446Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, { tags: [ "x_refsource_CONFIRM", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { tags: [ "x_refsource_CONFIRM", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC WinCC Runtime Advanced V15", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC WinCC Runtime Advanced V16", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SINAMICS GH150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS GL150 (with option X30)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS GM150 (with option X30)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SH150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SL150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SM120", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SM150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SM150i", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-401", description: "CWE-401: Missing Release of Memory after Effective Lifetime", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2021-10-12T09:49:18", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { tags: [ "x_refsource_MISC", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, { tags: [ "x_refsource_CONFIRM", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { tags: [ "x_refsource_CONFIRM", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2021-27386", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced V15", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced V16", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SINAMICS GH150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS GL150 (with option X30)", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS GM150 (with option X30)", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SH150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SL150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SM120", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SM150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SM150i", version: { version_data: [ { version_value: "All versions", }, ], }, }, ], }, vendor_name: "Siemens", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-401: Missing Release of Memory after Effective Lifetime", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { name: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", refsource: "MISC", url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", refsource: "CONFIRM", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", refsource: "CONFIRM", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2021-27386", datePublished: "2021-05-12T13:18:23", dateReserved: "2021-02-18T00:00:00", dateUpdated: "2024-08-03T20:48:16.446Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2018-13814 (GCVE-0-2018-13814)
Vulnerability from cvelistv5
Published
2018-12-13 16:00
Modified
2024-08-05 09:14
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
http://www.securityfocus.com/bid/105931 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens AG | SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) |
Version: SIMATIC HMI Comfort Panels 4" - 22" : All versions < V14 Version: SIMATIC HMI Comfort Outdoor Panels 7" & 15" : All versions < V14 Version: SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V14 Version: SIMATIC WinCC Runtime Advanced : All versions < V14 Version: SIMATIC WinCC Runtime Professional : All versions < V14 Version: SIMATIC WinCC (TIA Portal) : All versions < V14 Version: SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions |
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-05T09:14:47.244Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { name: "105931", tags: [ "vdb-entry", "x_refsource_BID", "x_transferred", ], url: "http://www.securityfocus.com/bid/105931", }, { tags: [ "x_refsource_CONFIRM", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" & 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", vendor: "Siemens AG", versions: [ { status: "affected", version: "SIMATIC HMI Comfort Panels 4\" - 22\" : All versions < V14", }, { status: "affected", version: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" : All versions < V14", }, { status: "affected", version: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V14", }, { status: "affected", version: "SIMATIC WinCC Runtime Advanced : All versions < V14", }, { status: "affected", version: "SIMATIC WinCC Runtime Professional : All versions < V14", }, { status: "affected", version: "SIMATIC WinCC (TIA Portal) : All versions < V14", }, { status: "affected", version: "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions", }, ], }, ], datePublic: "2018-12-13T00:00:00", descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-113", description: "CWE-113: Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting')", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2018-12-14T10:57:02", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { name: "105931", tags: [ "vdb-entry", "x_refsource_BID", ], url: "http://www.securityfocus.com/bid/105931", }, { tags: [ "x_refsource_CONFIRM", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2018-13814", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" & 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", version: { version_data: [ { version_value: "SIMATIC HMI Comfort Panels 4\" - 22\" : All versions < V14", }, { version_value: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" : All versions < V14", }, { version_value: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V14", }, { version_value: "SIMATIC WinCC Runtime Advanced : All versions < V14", }, { version_value: "SIMATIC WinCC Runtime Professional : All versions < V14", }, { version_value: "SIMATIC WinCC (TIA Portal) : All versions < V14", }, { version_value: "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions", }, ], }, }, ], }, vendor_name: "Siemens AG", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-113: Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting')", }, ], }, ], }, references: { reference_data: [ { name: "105931", refsource: "BID", url: "http://www.securityfocus.com/bid/105931", }, { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf", refsource: "CONFIRM", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2018-13814", datePublished: "2018-12-13T16:00:00", dateReserved: "2018-07-10T00:00:00", dateUpdated: "2024-08-05T09:14:47.244Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2019-6572 (GCVE-0-2019-6572)
Vulnerability from cvelistv5
Published
2019-05-14 19:54
Modified
2024-08-04 20:23
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf | x_refsource_MISC | |
http://www.securityfocus.com/bid/108412 | vdb-entry, x_refsource_BID | |
https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens AG | SIMATIC HMI Comfort Panels 4" - 22" |
Version: All versions < V15.1 Update 1 |
|||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-04T20:23:22.238Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { name: "108412", tags: [ "vdb-entry", "x_refsource_BID", "x_transferred", ], url: "http://www.securityfocus.com/bid/108412", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC HMI Comfort Panels 4\" - 22\"", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\"", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC WinCC Runtime Advanced", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC WinCC Runtime Professional", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC WinCC (TIA Portal)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-200", description: "CWE-200: Information Exposure", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2019-10-24T15:25:12", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { name: "108412", tags: [ "vdb-entry", "x_refsource_BID", ], url: "http://www.securityfocus.com/bid/108412", }, { tags: [ "x_refsource_MISC", ], url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2019-6572", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC HMI Comfort Panels 4\" - 22\"", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\"", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Professional", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC WinCC (TIA Portal)", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", version: { version_data: [ { version_value: "All versions", }, ], }, }, ], }, vendor_name: "Siemens AG", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-200: Information Exposure", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { name: "108412", refsource: "BID", url: "http://www.securityfocus.com/bid/108412", }, { name: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", refsource: "MISC", url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2019-6572", datePublished: "2019-05-14T19:54:48", dateReserved: "2019-01-22T00:00:00", dateUpdated: "2024-08-04T20:23:22.238Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2019-6577 (GCVE-0-2019-6577)
Vulnerability from cvelistv5
Published
2019-05-14 19:54
Modified
2024-08-04 20:23
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf | x_refsource_MISC | |
http://www.securityfocus.com/bid/108412 | vdb-entry, x_refsource_BID | |
https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens AG | SIMATIC HMI Comfort Panels 4" - 22" |
Version: All versions < V15.1 Update 1 |
|||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-04T20:23:22.189Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { name: "108412", tags: [ "vdb-entry", "x_refsource_BID", "x_transferred", ], url: "http://www.securityfocus.com/bid/108412", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC HMI Comfort Panels 4\" - 22\"", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\"", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC WinCC Runtime Advanced", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC WinCC Runtime Professional", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC WinCC (TIA Portal)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions < V15.1 Update 1", }, ], }, { product: "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-80", description: "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2019-10-24T15:27:02", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { name: "108412", tags: [ "vdb-entry", "x_refsource_BID", ], url: "http://www.securityfocus.com/bid/108412", }, { tags: [ "x_refsource_MISC", ], url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2019-6577", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC HMI Comfort Panels 4\" - 22\"", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\"", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Professional", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC WinCC (TIA Portal)", version: { version_data: [ { version_value: "All versions < V15.1 Update 1", }, ], }, }, { product_name: "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", version: { version_data: [ { version_value: "All versions", }, ], }, }, ], }, vendor_name: "Siemens AG", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { name: "108412", refsource: "BID", url: "http://www.securityfocus.com/bid/108412", }, { name: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", refsource: "MISC", url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2019-6577", datePublished: "2019-05-14T19:54:48", dateReserved: "2019-01-22T00:00:00", dateUpdated: "2024-08-04T20:23:22.189Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2018-13813 (GCVE-0-2018-13813)
Vulnerability from cvelistv5
Published
2018-12-13 16:00
Modified
2024-08-05 09:14
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
http://www.securityfocus.com/bid/105922 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens AG | SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) |
Version: SIMATIC HMI Comfort Panels 4" - 22" : All versions < V15 Update 4 Version: SIMATIC HMI Comfort Outdoor Panels 7" & 15" : All versions < V15 Update 4 Version: SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V15 Update 4 Version: SIMATIC WinCC Runtime Advanced : All versions < V15 Update 4 Version: SIMATIC WinCC Runtime Professional : All versions < V15 Update 4 Version: SIMATIC WinCC (TIA Portal) : All versions < V15 Update 4 Version: SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions |
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-05T09:14:47.263Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { name: "105922", tags: [ "vdb-entry", "x_refsource_BID", "x_transferred", ], url: "http://www.securityfocus.com/bid/105922", }, { tags: [ "x_refsource_CONFIRM", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" & 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", vendor: "Siemens AG", versions: [ { status: "affected", version: "SIMATIC HMI Comfort Panels 4\" - 22\" : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC WinCC Runtime Advanced : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC WinCC Runtime Professional : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC WinCC (TIA Portal) : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions", }, ], }, ], datePublic: "2018-12-13T00:00:00", descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-601", description: "CWE-601: URL Redirection to Untrusted Site ('Open Redirect')", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2018-12-14T10:57:02", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { name: "105922", tags: [ "vdb-entry", "x_refsource_BID", ], url: "http://www.securityfocus.com/bid/105922", }, { tags: [ "x_refsource_CONFIRM", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2018-13813", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" & 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", version: { version_data: [ { version_value: "SIMATIC HMI Comfort Panels 4\" - 22\" : All versions < V15 Update 4", }, { version_value: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" : All versions < V15 Update 4", }, { version_value: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V15 Update 4", }, { version_value: "SIMATIC WinCC Runtime Advanced : All versions < V15 Update 4", }, { version_value: "SIMATIC WinCC Runtime Professional : All versions < V15 Update 4", }, { version_value: "SIMATIC WinCC (TIA Portal) : All versions < V15 Update 4", }, { version_value: "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions", }, ], }, }, ], }, vendor_name: "Siemens AG", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-601: URL Redirection to Untrusted Site ('Open Redirect')", }, ], }, ], }, references: { reference_data: [ { name: "105922", refsource: "BID", url: "http://www.securityfocus.com/bid/105922", }, { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", refsource: "CONFIRM", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2018-13813", datePublished: "2018-12-13T16:00:00", dateReserved: "2018-07-10T00:00:00", dateUpdated: "2024-08-05T09:14:47.263Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2021-25661 (GCVE-0-2021-25661)
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:11
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags |
---|---|---|
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T20:11:27.591Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, { tags: [ "x_refsource_CONFIRM", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC WinCC Runtime Advanced V15", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC WinCC Runtime Advanced V16", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-788", description: "CWE-788: Access of Memory Location After End of Buffer", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2021-10-12T09:49:12", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, { tags: [ "x_refsource_CONFIRM", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2021-25661", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced V15", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced V16", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, ], }, vendor_name: "Siemens", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-788: Access of Memory Location After End of Buffer", }, ], }, ], }, references: { reference_data: [ { name: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", refsource: "MISC", url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", refsource: "CONFIRM", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2021-25661", datePublished: "2021-05-12T13:18:22", dateReserved: "2021-01-21T00:00:00", dateUpdated: "2024-08-03T20:11:27.591Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2021-27384 (GCVE-0-2021-27384)
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T20:48:16.461Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC WinCC Runtime Advanced V15", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC WinCC Runtime Advanced V16", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SINAMICS GH150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS GL150 (with option X30)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS GM150 (with option X30)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SH150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SL150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SM120", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SM150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SM150i", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-788", description: "CWE-788: Access of Memory Location After End of Buffer", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2021-10-12T09:49:16", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { tags: [ "x_refsource_MISC", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2021-27384", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced V15", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced V16", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SINAMICS GH150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS GL150 (with option X30)", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS GM150 (with option X30)", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SH150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SL150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SM120", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SM150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SM150i", version: { version_data: [ { version_value: "All versions", }, ], }, }, ], }, vendor_name: "Siemens", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-788: Access of Memory Location After End of Buffer", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { name: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", refsource: "MISC", url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2021-27384", datePublished: "2021-05-12T13:18:22", dateReserved: "2021-02-18T00:00:00", dateUpdated: "2024-08-03T20:48:16.461Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
CVE-2021-27385 (GCVE-0-2021-27385)
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T20:48:16.474Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SIMATIC WinCC Runtime Advanced V15", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V15.1 Update 6", }, ], }, { product: "SIMATIC WinCC Runtime Advanced V16", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V16 Update 4", }, ], }, { product: "SINAMICS GH150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS GL150 (with option X30)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS GM150 (with option X30)", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SH150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SL150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SM120", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SM150", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINAMICS SM150i", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-400", description: "CWE-400: Uncontrolled Resource Consumption", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2021-10-12T09:49:17", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { tags: [ "x_refsource_MISC", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2021-27385", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced V15", version: { version_data: [ { version_value: "All versions < V15.1 Update 6", }, ], }, }, { product_name: "SIMATIC WinCC Runtime Advanced V16", version: { version_data: [ { version_value: "All versions < V16 Update 4", }, ], }, }, { product_name: "SINAMICS GH150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS GL150 (with option X30)", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS GM150 (with option X30)", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SH150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SL150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SM120", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SM150", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINAMICS SM150i", version: { version_data: [ { version_value: "All versions", }, ], }, }, ], }, vendor_name: "Siemens", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-400: Uncontrolled Resource Consumption", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { name: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", refsource: "MISC", url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2021-27385", datePublished: "2021-05-12T13:18:23", dateReserved: "2021-02-18T00:00:00", dateUpdated: "2024-08-03T20:48:16.474Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", }
Vulnerability from fkie_nvd
Published
2018-12-13 16:29
Modified
2024-11-21 03:48
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/105922 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/105922 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_hmi_comfort_panels_firmware | * | |
siemens | simatic_hmi_comfort_panels | - | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_\(tia_portal\) | * | |
siemens | simatic_wincc_runtime | * | |
siemens | simatic_wincc_runtime | * | |
siemens | simatic_hmi_tp_firmware | * | |
siemens | simatic_hmi_tp | - | |
siemens | simatic_hmi_mp_firmware | * | |
siemens | simatic_hmi_mp | - | |
siemens | simatic_hmi_op_firmware | * | |
siemens | simatic_hmi_op | - |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3AD9AEE0-437E-45C7-BA3C-696628FA6883", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "C6D3259C-2DAF-4136-BAC3-28B234329E27", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "F4830E0D-0128-4E5B-AB81-2B238471AE4B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "1D090C01-A7A7-43C2-842F-50951D75B57A", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CE04B9B4-EFFF-447D-9D98-80EE43E926E9", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8B1F081F-E97A-445B-B6D5-E0AEFA3360C1", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7027573E-5E1E-4750-98AD-AC82DC5C1708", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0B26872E-A514-4CD7-98C9-2F8B6FD3DEEB", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:*:*:*:*", matchCriteriaId: "775A5747-AB92-4E27-9A74-7DF5368A5BA9", versionEndIncluding: "15.0", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*", matchCriteriaId: "5D1FBC31-3165-4057-A615-536D73A75311", versionEndIncluding: "15.0", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*", matchCriteriaId: "92C7789F-1646-485A-9889-5AD81B5F1105", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "983886F3-5B11-4AC3-A4D9-C2816F9A37DF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*", matchCriteriaId: "EE8F082D-04C4-4A3E-B3D1-6C2914C2917E", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A2271FBE-FF50-4614-A4A5-BBAB800F5FBD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*", matchCriteriaId: "68C30B3C-90EF-4244-9235-D87A421850DC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "217870AC-9EB0-4BDE-A2E2-381055B8E69C", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*", matchCriteriaId: "A17F4CDF-5367-4343-AA1E-0C452495E598", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels 4\" - 22\" (todas las versiones anteriores a V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" 15\" (todas las versiones anteriores a V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (todas las versiones anteriores a V15 Update 4), SIMATIC WinCC Runtime Advanced (todas las versiones anteriores a V15 Update 4), SIMATIC WinCC Runtime Professional (todas las versiones anteriores a V15 Update 4), SIMATIC WinCC (TIA Portal) (todas las versiones anteriores a V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (todas las versiones). El servidor web de los dispositivos HMI podría permitir redirecciones de URL a sitios web no fiables. Un atacante debe engañar a un usuario válido autenticado en el dispositivo para que haga clic en un enlace malicioso y explote esta vulnerabilidad. En el momento de la publicación del aviso, no se conoce ninguna explotación pública de la vulnerabilidad de seguridad.", }, ], id: "CVE-2018-13813", lastModified: "2024-11-21T03:48:07.380", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "MEDIUM", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "NONE", baseScore: 5.8, confidentialityImpact: "PARTIAL", integrityImpact: "PARTIAL", vectorString: "AV:N/AC:M/Au:N/C:P/I:P/A:N", version: "2.0", }, exploitabilityScore: 8.6, impactScore: 4.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: true, }, ], cvssMetricV30: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "NONE", baseScore: 8.1, baseSeverity: "HIGH", confidentialityImpact: "HIGH", integrityImpact: "HIGH", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "REQUIRED", vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N", version: "3.0", }, exploitabilityScore: 2.8, impactScore: 5.2, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2018-12-13T16:29:00.320", references: [ { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securityfocus.com/bid/105922", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securityfocus.com/bid/105922", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-601", }, ], source: "productcert@siemens.com", type: "Secondary", }, { description: [ { lang: "en", value: "CWE-601", }, ], source: "nvd@nist.gov", type: "Primary", }, ], }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | sinamics_sh150_firmware | * | |
siemens | sinamics_sh150 | - | |
siemens | sinamics_sm150i_firmware | * | |
siemens | sinamics_sm150i | - | |
siemens | sinamics_gh150_firmware | * | |
siemens | sinamics_gh150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | * | |
siemens | sinamics_sm120 | - | |
siemens | sinamics_sm150_firmware | * | |
siemens | sinamics_sm150 | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "C0891D85-C5F4-4CD2-8EFA-84356CE36654", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", matchCriteriaId: "E0005A53-33AD-47AF-B172-CAF423DE213F", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", matchCriteriaId: "9696B0D9-5A66-4747-9437-791EAC150DDA", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", matchCriteriaId: "F6AC2BA5-1668-4B71-8812-925AC6554F5A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", matchCriteriaId: "047D0868-3DA6-41CF-A6F9-D15668D536FB", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", matchCriteriaId: "EBC7AA8D-9046-4111-A263-38343997F984", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D6067521-A21D-4B2A-AFB2-2E033F66B63E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", matchCriteriaId: "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4BF9157D-0089-4569-9AA1-4DEE94140D25", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", matchCriteriaId: "BF977545-395A-4C34-BB22-A1047B5B6E85", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4D780400-0AA8-449C-B754-7167CA878D3D", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", matchCriteriaId: "DED7F33B-D475-4232-8683-48554A6729F7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "61CD50EE-6C46-445E-8D46-82768CAAC305", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", matchCriteriaId: "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E032554B-7F51-4482-AF55-743FFB5AC352", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", matchCriteriaId: "C6619B0F-7CDC-40A6-89B2-C6067AF45214", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CFFE3048-EEB0-48A0-BED0-8647284B022B", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", matchCriteriaId: "444DD77F-DB65-4766-A89D-7A679B4CA1E1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", matchCriteriaId: "2AE231E2-2B2B-407A-BF7A-9EA35F394229", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "244D9B27-649C-4983-B374-6A8774771AC5", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "A2530BB3-484C-4D24-82F6-15967C8B7B32", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "B5A1FACE-E693-4FDA-944D-0B7F500007B6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "6A673BD0-96B5-48CA-B060-A5D01687A764", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", matchCriteriaId: "C33A64DD-22A2-4260-929F-7595CD037823", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "9756D206-E295-4B0C-B159-F9A953342E37", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "F2D6D924-858A-4542-BCD0-A5631F941039", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "309E4D56-6D39-4E8F-8312-FF178B721392", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "EDB63639-3101-4F60-8193-EF219D99C128", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6C6C72B0-17D7-491E-816A-AF855166A90B", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D14DE5C7-318A-4D08-BB39-1E43F624816A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "21FB0305-DF87-42FF-BACA-E8255EA74AA9", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "BAA5B299-A45A-4918-AB8F-03A476CEDA17", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "0C29FD64-C041-4269-BC52-8F91321BC247", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "845C78A9-AE0F-42B9-9E25-47F541DF5196", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "B23096F5-3546-41D8-BE30-8698BC0C9B42", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D7C5AF13-69FF-444F-B84A-130D7413B307", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "66A17FC6-B6AE-4915-8069-68B41F3C87E2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4C618736-1382-4515-A295-6EC67A2731EA", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "BC0AD5A8-768E-4747-AD89-B924D369565E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "105CCE4B-D8F9-43EA-9089-CEE16A410751", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "0A4F6758-0B36-4546-A7A7-A4C71B63772E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "12A613F7-4EA4-40FF-931F-EF3C477300DA", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "4B048552-A26D-419E-9EEA-9AFD9457B70B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "BA4B198A-8288-459D-9586-CD402DE23023", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "D972823A-1128-4222-8910-9CA3D38B472F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "869AD837-79B1-4F76-947B-7DCAD172BDC0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "5C152EB8-A13A-4F16-994A-B6D93A017CC3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "9FE49F2D-B904-4E48-AAFD-669141B570F6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "729F784C-9AC0-4231-A75A-1FA8373FA31F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "FA61AC05-061D-4EE7-BFEF-568F30B9B883", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "FDE42199-9152-41A3-BE56-E6789315CF28", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "040F990F-F3C2-46EF-9E40-FD136A19575F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B37490B0-A214-4A62-9B67-934048921C1E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "3D7B9F45-5749-4F36-961D-6C5D650ADA07", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "F544593D-368B-4EC1-8448-8C2BA1301216", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "5F902732-9944-4821-BCFB-9937D1301FF6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "3EECF743-25E8-4483-AA68-B304B38A9290", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "2F557157-AAD6-4601-84C2-2F8574F23683", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A8EC6926-258F-4F5C-88D2-33FE363340DB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "97E283EF-A950-40E7-91C7-839203A333A5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "B5B130C2-28B8-464C-981C-B5662B4B4309", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "79407355-4181-4082-A661-C27734D95363", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "8989C7D4-5246-443E-B6E4-8E91462B2E96", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "B47671A7-A8DB-4DA2-9076-78708C7F1C42", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2D9CF819-E06C-4EAA-85B3-AC40E039D485", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4AF727E5-7849-4980-8AA5-7469FD52DF86", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "5052CB07-626A-46C4-8966-B8C9325A3BB3", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B28FB484-526A-437E-80E3-B62F54F1BEF6", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "81CE70BF-EBBE-4CD7-999C-25662670EFCB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "221EB3AE-1420-46F8-9EAD-1914503B0435", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "5F9A416C-277F-44B0-A74C-263CB0C37D03", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "FA858127-69A0-4280-80A8-65E0778A90AD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "A35D0B0C-695D-4274-8B9E-69ED20B62585", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "EA400339-123F-494A-8CD8-7232281E7D29", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "C8E943A5-E35C-4CFA-8998-A74385C8740B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8E4F0084-91A5-4D7E-971B-9DB979849594", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "36EEF9EB-91EF-4697-A963-7C8F955778EC", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "7BB0B884-C99A-4854-992F-8588840CC296", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "04BA4916-5693-4915-B4D7-29D97FA02474", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "DC588CE7-1F9D-43EF-A478-C23C8D909685", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "2DE08529-E210-48C1-A7C3-D2D316902A40", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "4D184A8F-963A-4730-AED4-1994EEA91702", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "16DAC92E-141C-4923-96F5-2620F60E763A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "8104E528-ED7D-451E-8834-057295A7FF49", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con opción X30) (Todas las versiones), SINAMICS GM150 (con opción X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). SmartVNC presenta una vulnerabilidad de fuga de asignación de la pila en el manejador de diseño del dispositivo en el lado del cliente, lo que podría resultar en una condición de Denegación de Servicio", }, ], id: "CVE-2021-27386", lastModified: "2024-11-21T05:57:53.533", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "PARTIAL", baseScore: 5, confidentialityImpact: "NONE", integrityImpact: "NONE", vectorString: "AV:N/AC:L/Au:N/C:N/I:N/A:P", version: "2.0", }, exploitabilityScore: 10, impactScore: 2.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2021-05-12T14:15:11.767", references: [ { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-401", }, ], source: "productcert@siemens.com", type: "Primary", }, { description: [ { lang: "en", value: "CWE-401", }, ], source: "nvd@nist.gov", type: "Secondary", }, ], }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | sinamics_sh150_firmware | * | |
siemens | sinamics_sh150 | - | |
siemens | sinamics_sm150i_firmware | * | |
siemens | sinamics_sm150i | - | |
siemens | sinamics_gh150_firmware | * | |
siemens | sinamics_gh150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | * | |
siemens | sinamics_sm120 | - | |
siemens | sinamics_sm150_firmware | * | |
siemens | sinamics_sm150 | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "C0891D85-C5F4-4CD2-8EFA-84356CE36654", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", matchCriteriaId: "E0005A53-33AD-47AF-B172-CAF423DE213F", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", matchCriteriaId: "9696B0D9-5A66-4747-9437-791EAC150DDA", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", matchCriteriaId: "F6AC2BA5-1668-4B71-8812-925AC6554F5A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", matchCriteriaId: "047D0868-3DA6-41CF-A6F9-D15668D536FB", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", matchCriteriaId: "EBC7AA8D-9046-4111-A263-38343997F984", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D6067521-A21D-4B2A-AFB2-2E033F66B63E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", matchCriteriaId: "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4BF9157D-0089-4569-9AA1-4DEE94140D25", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", matchCriteriaId: "BF977545-395A-4C34-BB22-A1047B5B6E85", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4D780400-0AA8-449C-B754-7167CA878D3D", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", matchCriteriaId: "DED7F33B-D475-4232-8683-48554A6729F7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "61CD50EE-6C46-445E-8D46-82768CAAC305", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", matchCriteriaId: "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E032554B-7F51-4482-AF55-743FFB5AC352", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", matchCriteriaId: "C6619B0F-7CDC-40A6-89B2-C6067AF45214", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CFFE3048-EEB0-48A0-BED0-8647284B022B", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", matchCriteriaId: "444DD77F-DB65-4766-A89D-7A679B4CA1E1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", matchCriteriaId: "2AE231E2-2B2B-407A-BF7A-9EA35F394229", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "244D9B27-649C-4983-B374-6A8774771AC5", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "A2530BB3-484C-4D24-82F6-15967C8B7B32", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "B5A1FACE-E693-4FDA-944D-0B7F500007B6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "6A673BD0-96B5-48CA-B060-A5D01687A764", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", matchCriteriaId: "C33A64DD-22A2-4260-929F-7595CD037823", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "9756D206-E295-4B0C-B159-F9A953342E37", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "F2D6D924-858A-4542-BCD0-A5631F941039", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "309E4D56-6D39-4E8F-8312-FF178B721392", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "EDB63639-3101-4F60-8193-EF219D99C128", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6C6C72B0-17D7-491E-816A-AF855166A90B", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D14DE5C7-318A-4D08-BB39-1E43F624816A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "21FB0305-DF87-42FF-BACA-E8255EA74AA9", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "BAA5B299-A45A-4918-AB8F-03A476CEDA17", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "0C29FD64-C041-4269-BC52-8F91321BC247", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "845C78A9-AE0F-42B9-9E25-47F541DF5196", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "B23096F5-3546-41D8-BE30-8698BC0C9B42", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D7C5AF13-69FF-444F-B84A-130D7413B307", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "66A17FC6-B6AE-4915-8069-68B41F3C87E2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4C618736-1382-4515-A295-6EC67A2731EA", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "BC0AD5A8-768E-4747-AD89-B924D369565E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "105CCE4B-D8F9-43EA-9089-CEE16A410751", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "0A4F6758-0B36-4546-A7A7-A4C71B63772E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "12A613F7-4EA4-40FF-931F-EF3C477300DA", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "4B048552-A26D-419E-9EEA-9AFD9457B70B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "BA4B198A-8288-459D-9586-CD402DE23023", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "D972823A-1128-4222-8910-9CA3D38B472F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "869AD837-79B1-4F76-947B-7DCAD172BDC0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "5C152EB8-A13A-4F16-994A-B6D93A017CC3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "9FE49F2D-B904-4E48-AAFD-669141B570F6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "729F784C-9AC0-4231-A75A-1FA8373FA31F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "FA61AC05-061D-4EE7-BFEF-568F30B9B883", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "FDE42199-9152-41A3-BE56-E6789315CF28", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "040F990F-F3C2-46EF-9E40-FD136A19575F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B37490B0-A214-4A62-9B67-934048921C1E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "3D7B9F45-5749-4F36-961D-6C5D650ADA07", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "F544593D-368B-4EC1-8448-8C2BA1301216", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "5F902732-9944-4821-BCFB-9937D1301FF6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "3EECF743-25E8-4483-AA68-B304B38A9290", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "2F557157-AAD6-4601-84C2-2F8574F23683", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A8EC6926-258F-4F5C-88D2-33FE363340DB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "97E283EF-A950-40E7-91C7-839203A333A5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "B5B130C2-28B8-464C-981C-B5662B4B4309", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "79407355-4181-4082-A661-C27734D95363", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "8989C7D4-5246-443E-B6E4-8E91462B2E96", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "B47671A7-A8DB-4DA2-9076-78708C7F1C42", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2D9CF819-E06C-4EAA-85B3-AC40E039D485", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4AF727E5-7849-4980-8AA5-7469FD52DF86", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "5052CB07-626A-46C4-8966-B8C9325A3BB3", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B28FB484-526A-437E-80E3-B62F54F1BEF6", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "81CE70BF-EBBE-4CD7-999C-25662670EFCB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "221EB3AE-1420-46F8-9EAD-1914503B0435", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "5F9A416C-277F-44B0-A74C-263CB0C37D03", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "FA858127-69A0-4280-80A8-65E0778A90AD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "A35D0B0C-695D-4274-8B9E-69ED20B62585", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "EA400339-123F-494A-8CD8-7232281E7D29", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "C8E943A5-E35C-4CFA-8998-A74385C8740B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8E4F0084-91A5-4D7E-971B-9DB979849594", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "36EEF9EB-91EF-4697-A963-7C8F955778EC", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "7BB0B884-C99A-4854-992F-8588840CC296", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "04BA4916-5693-4915-B4D7-29D97FA02474", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "DC588CE7-1F9D-43EF-A478-C23C8D909685", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "2DE08529-E210-48C1-A7C3-D2D316902A40", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "4D184A8F-963A-4730-AED4-1994EEA91702", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "16DAC92E-141C-4923-96F5-2620F60E763A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "8104E528-ED7D-451E-8834-057295A7FF49", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con la opción X30) (Todas las versiones), SINAMICS GM150 (with option X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). SmartVNC tiene una vulnerabilidad de fuga de asignación de heap en el codificador Tight del servidor, que podría dar lugar a una condición de denegación de servicio", }, ], id: "CVE-2021-27383", lastModified: "2024-11-21T05:57:53.060", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "PARTIAL", baseScore: 5, confidentialityImpact: "NONE", integrityImpact: "NONE", vectorString: "AV:N/AC:L/Au:N/C:N/I:N/A:P", version: "2.0", }, exploitabilityScore: 10, impactScore: 2.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2021-05-12T14:15:11.633", references: [ { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-770", }, ], source: "productcert@siemens.com", type: "Primary", }, { description: [ { lang: "en", value: "CWE-770", }, ], source: "nvd@nist.gov", type: "Secondary", }, ], }
Vulnerability from fkie_nvd
Published
2019-05-14 20:29
Modified
2024-11-21 04:46
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/108412 | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf | Vendor Advisory | |
productcert@siemens.com | https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | ||
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/108412 | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_hmi_comfort_panels_firmware | * | |
siemens | simatic_hmi_comfort_panels | - | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_\(tia_portal\) | * | |
siemens | simatic_wincc_runtime | * | |
siemens | simatic_wincc_runtime | * | |
siemens | simatic_hmi_tp_firmware | * | |
siemens | simatic_hmi_tp | - | |
siemens | simatic_hmi_mp_firmware | * | |
siemens | simatic_hmi_mp | - | |
siemens | simatic_hmi_op_firmware | * | |
siemens | simatic_hmi_op | - |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "865FD012-F390-4BB8-B14F-533840B95512", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7299F88D-8885-4871-93E1-CBEFD3156B15", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "F4830E0D-0128-4E5B-AB81-2B238471AE4B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A8EC6926-258F-4F5C-88D2-33FE363340DB", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2D9CF819-E06C-4EAA-85B3-AC40E039D485", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B28FB484-526A-437E-80E3-B62F54F1BEF6", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8E4F0084-91A5-4D7E-971B-9DB979849594", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:*:*:*:*", matchCriteriaId: "82389DAA-8D03-4806-AF86-87A1627A972F", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*", matchCriteriaId: "C24C17B5-C379-4FD1-BA9F-38B2A329F254", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*", matchCriteriaId: "24939BB3-7D99-4812-9EF8-65FE1FC9CCD8", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "983886F3-5B11-4AC3-A4D9-C2816F9A37DF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*", matchCriteriaId: "EE8F082D-04C4-4A3E-B3D1-6C2914C2917E", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A2271FBE-FF50-4614-A4A5-BBAB800F5FBD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*", matchCriteriaId: "68C30B3C-90EF-4244-9235-D87A421850DC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "217870AC-9EB0-4BDE-A2E2-381055B8E69C", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*", matchCriteriaId: "A17F4CDF-5367-4343-AA1E-0C452495E598", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.", }, { lang: "es", value: "Ha sido identificada una vulnerabilidad en SIMATIC HMI Comfort Panels 4\" - 22\" (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC WinCC Runtime Professional (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC WinCC (TIA Portal) (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (Todas las versiones). Un atacante con acceso de red a los dispositivos afectados podría obtener una clave de sesión TLS. Si el atacante puede observar el tráfico TLS entre un usuario legítimo y el dispositivo, entonces el atacante podría descifrar el tráfico TLS. La vulnerabilidad de la seguridad podría ser explotada por un atacante que tenga acceso de red a la interfaz web del dispositivo y que pueda observar el tráfico TLS entre usuarios legítimos y la interfaz web del dispositivo afectado. La vulnerabilidad podría afectar la confidencialidad de la comunicación entre el dispositivo afectado y un usuario legítimo. En el momento de la publicación de asesoramiento, no se conocía la explotación pública de la vulnerabilidad de seguridad.", }, ], id: "CVE-2019-6576", lastModified: "2024-11-21T04:46:44.130", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "NONE", baseScore: 5, confidentialityImpact: "PARTIAL", integrityImpact: "NONE", vectorString: "AV:N/AC:L/Au:N/C:P/I:N/A:N", version: "2.0", }, exploitabilityScore: 10, impactScore: 2.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV30: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "NONE", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "HIGH", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", version: "3.0", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2019-05-14T20:29:04.560", references: [ { source: "productcert@siemens.com", url: "http://www.securityfocus.com/bid/108412", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { source: "productcert@siemens.com", url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "http://www.securityfocus.com/bid/108412", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-310", }, ], source: "productcert@siemens.com", type: "Secondary", }, { description: [ { lang: "en", value: "CWE-310", }, ], source: "nvd@nist.gov", type: "Primary", }, ], }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:55
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "244D9B27-649C-4983-B374-6A8774771AC5", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "A2530BB3-484C-4D24-82F6-15967C8B7B32", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "B5A1FACE-E693-4FDA-944D-0B7F500007B6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "6A673BD0-96B5-48CA-B060-A5D01687A764", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", matchCriteriaId: "C33A64DD-22A2-4260-929F-7595CD037823", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "9756D206-E295-4B0C-B159-F9A953342E37", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "F2D6D924-858A-4542-BCD0-A5631F941039", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "309E4D56-6D39-4E8F-8312-FF178B721392", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "EDB63639-3101-4F60-8193-EF219D99C128", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6C6C72B0-17D7-491E-816A-AF855166A90B", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D14DE5C7-318A-4D08-BB39-1E43F624816A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "21FB0305-DF87-42FF-BACA-E8255EA74AA9", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "BAA5B299-A45A-4918-AB8F-03A476CEDA17", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "0C29FD64-C041-4269-BC52-8F91321BC247", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "845C78A9-AE0F-42B9-9E25-47F541DF5196", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "B23096F5-3546-41D8-BE30-8698BC0C9B42", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D7C5AF13-69FF-444F-B84A-130D7413B307", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "66A17FC6-B6AE-4915-8069-68B41F3C87E2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4C618736-1382-4515-A295-6EC67A2731EA", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "BC0AD5A8-768E-4747-AD89-B924D369565E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "105CCE4B-D8F9-43EA-9089-CEE16A410751", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "0A4F6758-0B36-4546-A7A7-A4C71B63772E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "12A613F7-4EA4-40FF-931F-EF3C477300DA", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "4B048552-A26D-419E-9EEA-9AFD9457B70B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "C0891D85-C5F4-4CD2-8EFA-84356CE36654", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", matchCriteriaId: "E0005A53-33AD-47AF-B172-CAF423DE213F", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", matchCriteriaId: "9696B0D9-5A66-4747-9437-791EAC150DDA", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", matchCriteriaId: "F6AC2BA5-1668-4B71-8812-925AC6554F5A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", matchCriteriaId: "047D0868-3DA6-41CF-A6F9-D15668D536FB", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "BA4B198A-8288-459D-9586-CD402DE23023", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "D972823A-1128-4222-8910-9CA3D38B472F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "869AD837-79B1-4F76-947B-7DCAD172BDC0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "5C152EB8-A13A-4F16-994A-B6D93A017CC3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "9FE49F2D-B904-4E48-AAFD-669141B570F6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "729F784C-9AC0-4231-A75A-1FA8373FA31F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "FA61AC05-061D-4EE7-BFEF-568F30B9B883", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "FDE42199-9152-41A3-BE56-E6789315CF28", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "040F990F-F3C2-46EF-9E40-FD136A19575F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B37490B0-A214-4A62-9B67-934048921C1E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "3D7B9F45-5749-4F36-961D-6C5D650ADA07", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "F544593D-368B-4EC1-8448-8C2BA1301216", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "5F902732-9944-4821-BCFB-9937D1301FF6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "3EECF743-25E8-4483-AA68-B304B38A9290", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "2F557157-AAD6-4601-84C2-2F8574F23683", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A8EC6926-258F-4F5C-88D2-33FE363340DB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "97E283EF-A950-40E7-91C7-839203A333A5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "B5B130C2-28B8-464C-981C-B5662B4B4309", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "79407355-4181-4082-A661-C27734D95363", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "8989C7D4-5246-443E-B6E4-8E91462B2E96", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "B47671A7-A8DB-4DA2-9076-78708C7F1C42", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2D9CF819-E06C-4EAA-85B3-AC40E039D485", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4AF727E5-7849-4980-8AA5-7469FD52DF86", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "5052CB07-626A-46C4-8966-B8C9325A3BB3", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B28FB484-526A-437E-80E3-B62F54F1BEF6", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "81CE70BF-EBBE-4CD7-999C-25662670EFCB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "221EB3AE-1420-46F8-9EAD-1914503B0435", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "5F9A416C-277F-44B0-A74C-263CB0C37D03", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "FA858127-69A0-4280-80A8-65E0778A90AD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "A35D0B0C-695D-4274-8B9E-69ED20B62585", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "EA400339-123F-494A-8CD8-7232281E7D29", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "C8E943A5-E35C-4CFA-8998-A74385C8740B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8E4F0084-91A5-4D7E-971B-9DB979849594", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "36EEF9EB-91EF-4697-A963-7C8F955778EC", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "7BB0B884-C99A-4854-992F-8588840CC296", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "04BA4916-5693-4915-B4D7-29D97FA02474", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "DC588CE7-1F9D-43EF-A478-C23C8D909685", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "2DE08529-E210-48C1-A7C3-D2D316902A40", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "4D184A8F-963A-4730-AED4-1994EEA91702", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "16DAC92E-141C-4923-96F5-2620F60E763A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "8104E528-ED7D-451E-8834-057295A7FF49", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" y 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4). SmartVNC presenta una vulnerabilidad de acceso a la memoria fuera de límites que podría ser desencadenada en el lado del servidor al enviar datos desde el cliente, lo que podría resultar en una condición de Denegación de Servicio", }, ], id: "CVE-2021-25660", lastModified: "2024-11-21T05:55:14.307", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "PARTIAL", baseScore: 5, confidentialityImpact: "NONE", integrityImpact: "NONE", vectorString: "AV:N/AC:L/Au:N/C:N/I:N/A:P", version: "2.0", }, exploitabilityScore: 10, impactScore: 2.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2021-05-12T14:15:11.253", references: [ { source: "productcert@siemens.com", tags: [ "Patch", "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Patch", "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-788", }, ], source: "productcert@siemens.com", type: "Primary", }, { description: [ { lang: "en", value: "CWE-119", }, ], source: "nvd@nist.gov", type: "Secondary", }, ], }
Vulnerability from fkie_nvd
Published
2019-05-14 20:29
Modified
2024-11-21 04:46
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/108412 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf | Vendor Advisory | |
productcert@siemens.com | https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/108412 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_hmi_comfort_panels_firmware | * | |
siemens | simatic_hmi_comfort_panels | - | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_\(tia_portal\) | * | |
siemens | simatic_wincc_runtime | * | |
siemens | simatic_wincc_runtime | * | |
siemens | simatic_hmi_tp_firmware | * | |
siemens | simatic_hmi_tp | - | |
siemens | simatic_hmi_mp_firmware | * | |
siemens | simatic_hmi_mp | - | |
siemens | simatic_hmi_op_firmware | * | |
siemens | simatic_hmi_op | - |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "865FD012-F390-4BB8-B14F-533840B95512", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7299F88D-8885-4871-93E1-CBEFD3156B15", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "F4830E0D-0128-4E5B-AB81-2B238471AE4B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A8EC6926-258F-4F5C-88D2-33FE363340DB", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2D9CF819-E06C-4EAA-85B3-AC40E039D485", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B28FB484-526A-437E-80E3-B62F54F1BEF6", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8E4F0084-91A5-4D7E-971B-9DB979849594", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:*:*:*:*", matchCriteriaId: "82389DAA-8D03-4806-AF86-87A1627A972F", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*", matchCriteriaId: "C24C17B5-C379-4FD1-BA9F-38B2A329F254", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*", matchCriteriaId: "24939BB3-7D99-4812-9EF8-65FE1FC9CCD8", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "983886F3-5B11-4AC3-A4D9-C2816F9A37DF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*", matchCriteriaId: "EE8F082D-04C4-4A3E-B3D1-6C2914C2917E", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A2271FBE-FF50-4614-A4A5-BBAB800F5FBD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*", matchCriteriaId: "68C30B3C-90EF-4244-9235-D87A421850DC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "217870AC-9EB0-4BDE-A2E2-381055B8E69C", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*", matchCriteriaId: "A17F4CDF-5367-4343-AA1E-0C452495E598", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", }, { lang: "es", value: "Ha sido identificada una vulnerabilidad en SIMATIC HMI Comfort Panels 4\" - 22\" (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC WinCC Runtime Professional (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC WinCC (TIA Portal) (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (Todas las versiones). El dispositivo afectado ofrecía capacidades de lectura y escritura de SNMP con una cadena de comunidad codificada públicamente. La vulnerabilidad de la seguridad podría ser explotada por un atacante con acceso de red al dispositivo afectado. La explotación con éxito no requiere privilegios del sistema ni interacción del usuario. Un atacante podría utilizar la vulnerabilidad para comprometer la confidencialidad y la integridad del sistema afectado. En el momento de la publicación de asesoramiento, no se conocía la explotación pública de esta vulnerabilidad de seguridad.", }, ], id: "CVE-2019-6572", lastModified: "2024-11-21T04:46:43.653", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "NONE", baseScore: 6.4, confidentialityImpact: "PARTIAL", integrityImpact: "PARTIAL", vectorString: "AV:N/AC:L/Au:N/C:P/I:P/A:N", version: "2.0", }, exploitabilityScore: 10, impactScore: 4.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "NONE", baseScore: 9.1, baseSeverity: "CRITICAL", confidentialityImpact: "HIGH", integrityImpact: "HIGH", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 5.2, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2019-05-14T20:29:04.200", references: [ { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securityfocus.com/bid/108412", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securityfocus.com/bid/108412", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-200", }, ], source: "productcert@siemens.com", type: "Secondary", }, { description: [ { lang: "en", value: "CWE-798", }, ], source: "nvd@nist.gov", type: "Primary", }, ], }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:55
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "C0891D85-C5F4-4CD2-8EFA-84356CE36654", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", matchCriteriaId: "E0005A53-33AD-47AF-B172-CAF423DE213F", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", matchCriteriaId: "9696B0D9-5A66-4747-9437-791EAC150DDA", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", matchCriteriaId: "F6AC2BA5-1668-4B71-8812-925AC6554F5A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", matchCriteriaId: "047D0868-3DA6-41CF-A6F9-D15668D536FB", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "244D9B27-649C-4983-B374-6A8774771AC5", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "A2530BB3-484C-4D24-82F6-15967C8B7B32", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "B5A1FACE-E693-4FDA-944D-0B7F500007B6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "6A673BD0-96B5-48CA-B060-A5D01687A764", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", matchCriteriaId: "C33A64DD-22A2-4260-929F-7595CD037823", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "9756D206-E295-4B0C-B159-F9A953342E37", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "F2D6D924-858A-4542-BCD0-A5631F941039", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "309E4D56-6D39-4E8F-8312-FF178B721392", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "EDB63639-3101-4F60-8193-EF219D99C128", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6C6C72B0-17D7-491E-816A-AF855166A90B", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D14DE5C7-318A-4D08-BB39-1E43F624816A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "21FB0305-DF87-42FF-BACA-E8255EA74AA9", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "BAA5B299-A45A-4918-AB8F-03A476CEDA17", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "0C29FD64-C041-4269-BC52-8F91321BC247", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "845C78A9-AE0F-42B9-9E25-47F541DF5196", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "B23096F5-3546-41D8-BE30-8698BC0C9B42", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D7C5AF13-69FF-444F-B84A-130D7413B307", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "66A17FC6-B6AE-4915-8069-68B41F3C87E2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4C618736-1382-4515-A295-6EC67A2731EA", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "BC0AD5A8-768E-4747-AD89-B924D369565E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "105CCE4B-D8F9-43EA-9089-CEE16A410751", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "0A4F6758-0B36-4546-A7A7-A4C71B63772E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "12A613F7-4EA4-40FF-931F-EF3C477300DA", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "4B048552-A26D-419E-9EEA-9AFD9457B70B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "BA4B198A-8288-459D-9586-CD402DE23023", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "D972823A-1128-4222-8910-9CA3D38B472F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "869AD837-79B1-4F76-947B-7DCAD172BDC0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "5C152EB8-A13A-4F16-994A-B6D93A017CC3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "9FE49F2D-B904-4E48-AAFD-669141B570F6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "729F784C-9AC0-4231-A75A-1FA8373FA31F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "FA61AC05-061D-4EE7-BFEF-568F30B9B883", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "FDE42199-9152-41A3-BE56-E6789315CF28", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "040F990F-F3C2-46EF-9E40-FD136A19575F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B37490B0-A214-4A62-9B67-934048921C1E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "3D7B9F45-5749-4F36-961D-6C5D650ADA07", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "F544593D-368B-4EC1-8448-8C2BA1301216", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "5F902732-9944-4821-BCFB-9937D1301FF6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "3EECF743-25E8-4483-AA68-B304B38A9290", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "2F557157-AAD6-4601-84C2-2F8574F23683", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A8EC6926-258F-4F5C-88D2-33FE363340DB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "97E283EF-A950-40E7-91C7-839203A333A5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "B5B130C2-28B8-464C-981C-B5662B4B4309", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "79407355-4181-4082-A661-C27734D95363", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "8989C7D4-5246-443E-B6E4-8E91462B2E96", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "B47671A7-A8DB-4DA2-9076-78708C7F1C42", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2D9CF819-E06C-4EAA-85B3-AC40E039D485", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4AF727E5-7849-4980-8AA5-7469FD52DF86", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "5052CB07-626A-46C4-8966-B8C9325A3BB3", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B28FB484-526A-437E-80E3-B62F54F1BEF6", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "81CE70BF-EBBE-4CD7-999C-25662670EFCB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "221EB3AE-1420-46F8-9EAD-1914503B0435", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "5F9A416C-277F-44B0-A74C-263CB0C37D03", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "FA858127-69A0-4280-80A8-65E0778A90AD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "A35D0B0C-695D-4274-8B9E-69ED20B62585", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "EA400339-123F-494A-8CD8-7232281E7D29", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "C8E943A5-E35C-4CFA-8998-A74385C8740B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8E4F0084-91A5-4D7E-971B-9DB979849594", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "36EEF9EB-91EF-4697-A963-7C8F955778EC", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "7BB0B884-C99A-4854-992F-8588840CC296", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "04BA4916-5693-4915-B4D7-29D97FA02474", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "DC588CE7-1F9D-43EF-A478-C23C8D909685", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "2DE08529-E210-48C1-A7C3-D2D316902A40", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "4D184A8F-963A-4730-AED4-1994EEA91702", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "16DAC92E-141C-4923-96F5-2620F60E763A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "8104E528-ED7D-451E-8834-057295A7FF49", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4). SmartVNC tiene una vulnerabilidad de acceso a la memoria fuera de los límites que podría activarse en el lado del cliente al enviar datos desde el servidor, lo que podría dar lugar a una condición de denegación de servicio", }, ], id: "CVE-2021-25661", lastModified: "2024-11-21T05:55:14.483", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "PARTIAL", baseScore: 5, confidentialityImpact: "NONE", integrityImpact: "NONE", vectorString: "AV:N/AC:L/Au:N/C:N/I:N/A:P", version: "2.0", }, exploitabilityScore: 10, impactScore: 2.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2021-05-12T14:15:11.300", references: [ { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-788", }, ], source: "productcert@siemens.com", type: "Primary", }, ], }
Vulnerability from fkie_nvd
Published
2019-04-17 14:29
Modified
2024-11-21 04:46
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
The webserver of the affected devices contains a vulnerability that may lead to
a denial of service condition. An attacker may cause a denial of service
situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network
access to the affected systems. Successful exploitation requires no system
privileges and no user interaction. An attacker could use the vulnerability
to compromise availability of the device.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | cp1604_firmware | * | |
siemens | cp1604 | - | |
siemens | cp1616_firmware | * | |
siemens | cp1616 | - | |
siemens | simatic_rf185c_firmware | * | |
siemens | simatic_rf185c | - | |
siemens | simatic_cp343-1_advanced_firmware | * | |
siemens | simatic_cp343-1_advanced | - | |
siemens | simatic_cp443-1_firmware | * | |
siemens | simatic_cp443-1 | - | |
siemens | simatic_cp443-1_advanced_firmware | * | |
siemens | simatic_cp443-1_advanced | - | |
siemens | simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware | * | |
siemens | simatic_et_200_sp_open_controller_cpu_1515sp_pc | - | |
siemens | simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware | * | |
siemens | simatic_et_200_sp_open_controller_cpu_1515sp_pc2 | - | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels | - | |
siemens | simatic_hmi_comfort_panels_firmware | * | |
siemens | simatic_hmi_comfort_panels_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_cp443-1_opc_ua | * | |
siemens | simatic_ipc_diagmonitor | * | |
siemens | simatic_s7-1500_software_controller | * | |
siemens | simatic_s7-plcsim_advanced | * | |
siemens | simatic_s7-plcsim_advanced | 2.0 | |
siemens | simatic_s7-plcsim_advanced | 2.0 | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | sitop_manager | * | |
siemens | simatic_rf600r_firmware | * | |
siemens | simatic_rf600r | - | |
siemens | simatic_rf188c_firmware | * | |
siemens | simatic_rf188c | - | |
siemens | simatic_rf186c_firmware | * | |
siemens | simatic_rf186c | - | |
siemens | simatic_rf182c_firmware | * | |
siemens | simatic_rf182c | - | |
siemens | simatic_rf181-eip_firmware | * | |
siemens | simatic_rf181-eip | - | |
siemens | simatic_s7-1500_firmware | * | |
siemens | simatic_s7-1500 | - | |
siemens | simatic_s7-300_firmware | * | |
siemens | simatic_s7-300 | - | |
siemens | simatic_s7-400_pn_firmware | * | |
siemens | simatic_s7-400_pn | - | |
siemens | simatic_s7-400_pn\/dp_firmware | * | |
siemens | simatic_s7-400_pn\/dp | - | |
siemens | simatic_teleservice_adapter_ie_advanced_firmware | * | |
siemens | simatic_teleservice_adapter_ie_advanced | - | |
siemens | simatic_teleservice_adapter_ie_basic_firmware | * | |
siemens | simatic_teleservice_adapter_ie_basic | - | |
siemens | simatic_teleservice_adapter_ie_standard_firmware | * | |
siemens | simatic_teleservice_adapter_ie_standard | - | |
siemens | simatic_winac_rtx_firmware | * | |
siemens | simatic_winac_rtx_firmware | 2010 | |
siemens | simatic_winac_rtx | - | |
siemens | simocode_pro_v_eip_firmware | * | |
siemens | simocode_pro_v_eip | - | |
siemens | simocode_pro_v_pn_firmware | * | |
siemens | simocode_pro_v_pn | - | |
siemens | sinamics_g130_firmware | * | |
siemens | sinamics_g130 | - | |
siemens | sinamics_g150_firmware | * | |
siemens | sinamics_g150 | - | |
siemens | sinamics_s120_firmware | * | |
siemens | sinamics_s120 | - | |
siemens | sinamics_s150_firmware | * | |
siemens | sinamics_s150_firmware | 5.1 | |
siemens | sinamics_s150_firmware | 5.1 | |
siemens | sinamics_s150_firmware | 5.1 | |
siemens | sinamics_s150 | - | |
siemens | sinamics_s210_firmware | * | |
siemens | sinamics_s210_firmware | 5.1 | |
siemens | sinamics_s210_firmware | 5.1 | |
siemens | sinamics_s210 | - | |
siemens | sitop_psu8600_firmware | * | |
siemens | sitop_psu8600 | - | |
siemens | sitop_ups1600_firmware | * | |
siemens | sitop_ups1600 | - | |
siemens | tim_1531_irc_firmware | * | |
siemens | tim_1531_irc | - | |
siemens | simatic_s7-1500f_firmware | * | |
siemens | simatic_s7-1500f | - | |
siemens | simatic_s7-1500s_firmware | * | |
siemens | simatic_s7-1500s | - | |
siemens | simatic_s7-1500t_firmware | * | |
siemens | simatic_s7-1500t | - | |
siemens | sinamics_gh150_firmware | * | |
siemens | sinamics_gh150_firmware | 4.8 | |
siemens | sinamics_gh150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150_firmware | 4.8 | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150_firmware | 4.8 | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150_firmware | 4.8 | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | * | |
siemens | sinamics_sm120_firmware | 4.8 | |
siemens | sinamics_sm120 | - | |
siemens | sinamics_sm150_firmware | * | |
siemens | sinamics_sm150_firmware | 5.1 | |
siemens | sinamics_sm150 | - |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:cp1604_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E737620D-9D00-4151-B232-7DFB7FD768B3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:cp1604:-:*:*:*:*:*:*:*", matchCriteriaId: "6222006F-09D7-49F7-B8C7-4D94298A8F6A", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:cp1616_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "65FE6F54-1457-4EB6-9273-1D93B3B97386", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:cp1616:-:*:*:*:*:*:*:*", matchCriteriaId: "184365A2-BAD2-4926-ACEE-F71E018D3CE5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "69EE2BF6-3846-478F-9AC6-BEF34617F3B5", versionEndExcluding: "1.1.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*", matchCriteriaId: "82494B5E-80EE-47ED-B87E-CF8C8907B6FE", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp343-1_advanced_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "1E6601B8-E032-4B39-BF65-F25CF047EB99", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp343-1_advanced:-:*:*:*:*:*:*:*", matchCriteriaId: "ACCC0229-E454-4BEF-931A-3CD820500822", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp443-1_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2035A020-F41E-4FC7-A290-9923574D4921", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp443-1:-:*:*:*:*:*:*:*", matchCriteriaId: "EB8636E9-A3DA-4DDC-A3FC-B3EAAD07952E", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp443-1_advanced_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "1AD15638-8B84-4DA2-9DDC-9A1CA3548E91", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp443-1_advanced:-:*:*:*:*:*:*:*", matchCriteriaId: "BFE94F56-71DB-4837-9818-6827C80DE2BC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D1873751-81F4-4732-B30F-9F2DEECBC110", versionEndExcluding: "2.1.6", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*", matchCriteriaId: "C9A5678E-9EAA-441A-AC77-94F824D64AEE", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "F36AC571-C958-4CB8-91D9-5417C1812C02", versionEndExcluding: "2.7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*", matchCriteriaId: "00361A3C-60E9-4365-BB51-09D7792C441D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7299F88D-8885-4871-93E1-CBEFD3156B15", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "F18EA7BD-47D0-4367-8F18-C89239B201E3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "F4830E0D-0128-4E5B-AB81-2B238471AE4B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "865FD012-F390-4BB8-B14F-533840B95512", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "5418D916-49A6-4B79-A653-E2C5221DEBE8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A8EC6926-258F-4F5C-88D2-33FE363340DB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "97E283EF-A950-40E7-91C7-839203A333A5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2D9CF819-E06C-4EAA-85B3-AC40E039D485", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4AF727E5-7849-4980-8AA5-7469FD52DF86", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B28FB484-526A-437E-80E3-B62F54F1BEF6", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8E4F0084-91A5-4D7E-971B-9DB979849594", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "36EEF9EB-91EF-4697-A963-7C8F955778EC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_cp443-1_opc_ua:*:*:*:*:*:*:*:*", matchCriteriaId: "56396833-12BF-4AE5-8D3E-695652A99DBF", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_ipc_diagmonitor:*:*:*:*:*:*:*:*", matchCriteriaId: "6FD49A39-47D7-473C-9E46-6D9246BC6D04", versionEndExcluding: "5.1.3", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*", matchCriteriaId: "11C0A94D-5506-4A75-99E1-CA9769AF057C", versionEndExcluding: "2.7", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "8B66A2A4-5062-45F8-A615-2DA716650909", versionEndExcluding: "2.0", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:2.0:-:*:*:*:*:*:*", matchCriteriaId: "AED3A3AF-EF77-4E58-91AD-BBE01E1DA4A6", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:2.0:sp1:*:*:*:*:*:*", matchCriteriaId: "23039930-E45C-4B0E-883A-E2F9A7502984", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "4D184A8F-963A-4730-AED4-1994EEA91702", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "16DAC92E-141C-4923-96F5-2620F60E763A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sitop_manager:*:*:*:*:*:*:*:*", matchCriteriaId: "2662688E-6975-46C7-939B-25FF4790518D", versionEndExcluding: "1.1", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_rf600r_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "16CBED3D-892A-4EC0-BE2E-358040C34304", versionEndExcluding: "3.2.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_rf600r:-:*:*:*:*:*:*:*", matchCriteriaId: "EFA55275-691D-4269-93E4-C559C89E3FA3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "25F96DAA-696D-4EB4-97DF-986C7681700B", versionEndExcluding: "1.1.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*", matchCriteriaId: "E21F9909-8D80-40BE-81E0-6ED7FE140A3A", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CF8FFD1C-8E33-48E9-A884-B80311F8BA4C", versionEndExcluding: "1.1.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*", matchCriteriaId: "9B0933EB-82BE-42BB-978B-C9EC2FE1C795", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_rf182c_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0FC4F972-3A3B-421C-8D62-9C5C4D1992CF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_rf182c:-:*:*:*:*:*:*:*", matchCriteriaId: "7540DAD9-2AAC-46A9-B1C5-BB1AC4FCE710", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_rf181-eip_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "AFA94867-4367-4186-8A4B-44C3CBCCEF7F", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_rf181-eip:-:*:*:*:*:*:*:*", matchCriteriaId: "E10A0D57-8805-44DB-95E3-1B240ED5ED09", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2AE766CD-695B-4A12-8BC5-3743D8E3D73E", versionEndExcluding: "2.6.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*", matchCriteriaId: "30DDEA9B-E1BF-4572-8E12-D13C54603E77", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-300_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9461CADE-1624-4D1B-8CF2-CF65F75071C0", versionEndExcluding: "3.3.17", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*", matchCriteriaId: "7EFD4E99-5C66-443F-8B6F-FA01C895DE78", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-400_pn_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0A2219FE-2C3F-4948-85D6-3C53AC08722B", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-400_pn:-:*:*:*:*:*:*:*", matchCriteriaId: "795D0FF9-1D0B-4C74-BEF3-58EAE74DFA0C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BC917346-94F6-44FD-AC00-AED0CF3CBBD1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp:-:*:*:*:*:*:*:*", matchCriteriaId: "F60D816D-85A5-4971-AF2D-666AE0B74E9E", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "C8E76BDE-C7E9-4D6B-B5D9-A456516CD016", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced:-:*:*:*:*:*:*:*", matchCriteriaId: "71DA3D1A-E435-418F-9A13-945B4BA15FC7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "80D166A8-1EEC-42F4-8EAB-1747247A7A05", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic:-:*:*:*:*:*:*:*", matchCriteriaId: "FFA520B6-5177-43E4-87C0-C215F79FE9B4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_standard_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "5C887573-8BE8-42CF-B35A-22F9311AC627", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_standard:-:*:*:*:*:*:*:*", matchCriteriaId: "3A5A3F7E-D039-430F-89B0-6AB4FD2428D4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "80BDBB38-20D2-48C3-8B58-62C2D8CC00B8", versionEndExcluding: "2010", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*", matchCriteriaId: "EA59D713-F342-4CDA-BDC8-108352D385DA", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*", matchCriteriaId: "CA5ADAB0-3985-4933-8CDD-D1546D8271CC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simocode_pro_v_eip_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8A001968-C7FD-4C11-8439-11532B234CC2", versionEndExcluding: "1.1.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simocode_pro_v_eip:-:*:*:*:*:*:*:*", matchCriteriaId: "50BDA360-0D33-42DC-ADB9-2F69503C2CD8", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simocode_pro_v_pn_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "15CB26DA-7CA0-4BD6-A219-01F6E8A6F03F", versionEndExcluding: "2.1.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simocode_pro_v_pn:-:*:*:*:*:*:*:*", matchCriteriaId: "1779AE78-AC90-48BE-8FF2-CC11E7CA3CB4", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "856768D2-C096-4CA7-B26F-E94B005C0D79", versionEndExcluding: "5.2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", matchCriteriaId: "373DBE44-AC28-4D04-93BB-35CD8C60E899", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "C579C2C7-0402-46B2-A770-C3B7F71D1096", versionEndExcluding: "5.2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", matchCriteriaId: "2296CA65-0E89-4BCB-8003-E7212BF1F585", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "03F9CBC3-B2B3-4FA7-963D-A8F3AE6D8EA0", versionEndExcluding: "5.2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", matchCriteriaId: "E5A824BD-935F-4E53-8313-C5544B0489C7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "126AC93E-A39F-4754-9707-207C9F2F64F4", versionEndExcluding: "5.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:-:*:*:*:*:*:*", matchCriteriaId: "3E8BCCED-BDC6-4785-8705-799836E5024E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:sp1:*:*:*:*:*:*", matchCriteriaId: "098262CC-4D3B-4E55-83C3-2816403C553B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:sp1_hotfix2:*:*:*:*:*:*", matchCriteriaId: "6092F899-9A89-4FA4-BD80-97511DF7CF8F", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*", matchCriteriaId: "0D48682C-A39D-4A09-B904-50FA64A9D2A5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B7269713-6505-41DF-B85B-F729E24A3F5B", versionEndExcluding: "5.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:-:*:*:*:*:*:*", matchCriteriaId: "BEBF14B3-65A0-41E9-B99C-D88548F307CD", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:sp1:*:*:*:*:*:*", matchCriteriaId: "F151297C-3097-483F-98B5-0261BD547421", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_s210:-:*:*:*:*:*:*:*", matchCriteriaId: "7BFA8FB3-12A9-4D2E-BCFD-C66313521C80", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6F389808-001E-4650-86B2-00A72D25BCD0", versionEndExcluding: "1.5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*", matchCriteriaId: "55058209-8AE5-42AF-80D4-5A7A44307266", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sitop_ups1600_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "BD39CC96-ABE3-4854-A102-36AFE1F6CB14", versionEndExcluding: "2.3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sitop_ups1600:-:*:*:*:*:*:*:*", matchCriteriaId: "6FC1A64E-6A27-4F91-8A13-829E0F7D8E80", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B023E75A-B76D-4FD8-9660-1F233092160F", versionEndExcluding: "2.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*", matchCriteriaId: "C1D94BEB-BBFB-4258-9835-87DBBB999239", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "F9C47A4A-BE81-499A-AB36-491661B88693", versionEndExcluding: "2.6.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500f:-:*:*:*:*:*:*:*", matchCriteriaId: "A255BC06-2776-4111-A525-76B17371B295", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500s_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "66A446D2-39ED-4635-AAA0-85D977F600FE", versionEndExcluding: "2.6.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500s:-:*:*:*:*:*:*:*", matchCriteriaId: "C1752A2A-0034-4E00-AAC6-FA15345D7A41", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500t_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "5238622A-BCAD-4A06-9920-49BECFDDC2A6", versionEndExcluding: "2.6.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500t:-:*:*:*:*:*:*:*", matchCriteriaId: "741B2C38-174C-49DF-98D8-F7D6F49D1CE5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6E231DE7-8B8D-41A3-A163-CE8EF50AF9D0", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.8:-:*:*:*:*:*:*", matchCriteriaId: "6D076504-AFE3-4C51-80E5-C5992CA7D511", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", matchCriteriaId: "BF977545-395A-4C34-BB22-A1047B5B6E85", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3653DA37-DB23-41E0-8CE8-838E384AA40A", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*", matchCriteriaId: "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", matchCriteriaId: "DED7F33B-D475-4232-8683-48554A6729F7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0E25804D-D943-4C2A-9C78-AAC61F7BA4FF", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*", matchCriteriaId: "06B69CD4-3AEC-4014-81DB-33805A44A5D3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", matchCriteriaId: "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FD67D30A-8681-41AE-B248-7E50BA1B9FC8", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.8:-:*:*:*:*:*:*", matchCriteriaId: "FCC0EE8B-1088-46B6-992A-B8E12A7B7DC2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", matchCriteriaId: "C6619B0F-7CDC-40A6-89B2-C6067AF45214", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "31393A1B-4DBC-476D-875E-463B4B887E1B", versionEndExcluding: "4.8", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_sm120_firmware:4.8:-:*:*:*:*:*:*", matchCriteriaId: "0206F9F2-27C7-4D2F-817B-13F8FA31E547", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", matchCriteriaId: "444DD77F-DB65-4766-A89D-7A679B4CA1E1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FC70D596-AA1E-4196-87B0-BECEE6568AA7", versionEndExcluding: "5.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:sinamics_sm150_firmware:5.1:-:*:*:*:*:*:*", matchCriteriaId: "1E81CDB5-122F-48D1-B9F1-4C401D46D978", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", matchCriteriaId: "2AE231E2-2B2B-407A-BF7A-9EA35F394229", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, ], cveTags: [], descriptions: [ { lang: "en", value: "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device.", }, { lang: "es", value: "SIPLUS), paneles exteriores SIMATIC HMI Comfort de 7\" y 15\" (incl. variantes SIPLUS), paneles SIMATIC HMI Comfort de 4\" - 22\" (incl. variantes SIPLUS), paneles SIMATIC ET 200SP Open Controller CPU 1515SP PC SIPLUS), paneles móviles SIMATIC HMI KTP KTP400F, KTP700, KTP700F, KTP900 y KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, familia SIMATIC RF600R, familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 y variantes SIPLUS), controlador de software SIMATIC S7-1500, familia de CPUs SIMATIC S7-300 (incluidas las CPUs ET200 y variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V6 e inferiores (incluidas las variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incluidas las variantes SIPLUS) SIPLUS), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP (incl. SIPLUS), SIMOCODE pro V PN (incl. variantes SIPLUS), SINAMICS G130 V4.6 Control Unit, SINAMICS G130 V4.7 Control Unit, SINAMICS G130 V4.7 SP1 Control Unit, SINAMICS G130 V4.8 Control Unit, SINAMICS G130 V5.1 Control Unit, SINAMICS G130 V5. 1 SP1 Unidad de control, SINAMICS G150 V4.6 Unidad de control, SINAMICS G150 V4.7 Unidad de control, SINAMICS G150 V4.7 SP1 Unidad de control, SINAMICS G150 V4.8 Unidad de control, SINAMICS G150 V5. 1 Unidad de control, SINAMICS G150 V5.1 SP1 Unidad de control, SINAMICS GH150 V4.7 (Unidad de control), SINAMICS GH150 V4.8 (Unidad de control), SINAMICS GL150 V4.7 (Unidad de control), SINAMICS GL150 V4. 8 (Unidad de control), SINAMICS GM150 V4.7 (Unidad de control), SINAMICS GM150 V4.8 (Unidad de control), SINAMICS S120 V4.6 Unidad de control (incl. variantes SIPLUS), SINAMICS S120 V4.7 Unidad de control (incl. variantes SIPLUS) SIPLUS), SINAMICS S120 V4.7 SP1 (incl. variantes SIPLUS), SINAMICS S120 V4.8 (incl. variantes SIPLUS), SINAMICS S120 V5.1 (incl. variantes SIPLUS) SIPLUS), SINAMICS S120 V5.1 SP1 Unidad de Control (incl. variantes SIPLUS), SINAMICS S150 V4.6 Unidad de Control, SINAMICS S150 V4.7 Unidad de Control, SINAMICS S150 V4.7 SP1 Unidad de Control, SINAMICS S150 V4. 8 Unidad de control, SINAMICS S150 V5.1 Unidad de control, SINAMICS S150 V5.1 SP1 Unidad de control, SINAMICS S210 V5.1 Unidad de control, SINAMICS S210 V5.1 SP1 Unidad de control, SINAMICS SL150 V4. 7 (Unidad de Control), SINAMICS SL150 V4.8 (Unidad de Control), SINAMICS SM120 V4.7 (Unidad de Control), SINAMICS SM120 V4.8 (Unidad de Control), SINAMICS SM150 V4. 8 (unidad de control), SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SITOP Manager, SITOP PSU8600, SITOP UPS1600 (incl. variantes SIPLUS), TIM 1531 IRC (incl. variantes SIPLUS NET). El servidor web de los dispositivos afectados contiene una vulnerabilidad que puede conducir a una condición de denegación de servicio. Un atacante puede provocar una situación de denegación de servicio que lleve a reiniciar el servidor web del dispositivo afectado. La vulnerabilidad de seguridad podría ser explotada por un atacante con acceso a la red de los sistemas afectados. La explotación exitosa no requiere privilegios del sistema ni interacción del usuario. Un atacante podría utilizar la vulnerabilidad para comprometer la disponibilidad del dispositivo", }, ], id: "CVE-2019-6568", lastModified: "2024-11-21T04:46:42.773", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "PARTIAL", baseScore: 5, confidentialityImpact: "NONE", integrityImpact: "NONE", vectorString: "AV:N/AC:L/Au:N/C:N/I:N/A:P", version: "2.0", }, exploitabilityScore: 10, impactScore: 2.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "productcert@siemens.com", type: "Secondary", }, { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "nvd@nist.gov", type: "Secondary", }, ], }, published: "2019-04-17T14:29:03.683", references: [ { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-125", }, ], source: "productcert@siemens.com", type: "Primary", }, { description: [ { lang: "en", value: "CWE-125", }, ], source: "nvd@nist.gov", type: "Secondary", }, ], }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:55
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "C0891D85-C5F4-4CD2-8EFA-84356CE36654", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", matchCriteriaId: "E0005A53-33AD-47AF-B172-CAF423DE213F", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", matchCriteriaId: "9696B0D9-5A66-4747-9437-791EAC150DDA", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", matchCriteriaId: "F6AC2BA5-1668-4B71-8812-925AC6554F5A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", matchCriteriaId: "047D0868-3DA6-41CF-A6F9-D15668D536FB", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "244D9B27-649C-4983-B374-6A8774771AC5", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "A2530BB3-484C-4D24-82F6-15967C8B7B32", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "B5A1FACE-E693-4FDA-944D-0B7F500007B6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "6A673BD0-96B5-48CA-B060-A5D01687A764", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", matchCriteriaId: "C33A64DD-22A2-4260-929F-7595CD037823", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "9756D206-E295-4B0C-B159-F9A953342E37", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "F2D6D924-858A-4542-BCD0-A5631F941039", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "309E4D56-6D39-4E8F-8312-FF178B721392", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "EDB63639-3101-4F60-8193-EF219D99C128", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6C6C72B0-17D7-491E-816A-AF855166A90B", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D14DE5C7-318A-4D08-BB39-1E43F624816A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "21FB0305-DF87-42FF-BACA-E8255EA74AA9", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "BAA5B299-A45A-4918-AB8F-03A476CEDA17", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "0C29FD64-C041-4269-BC52-8F91321BC247", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "845C78A9-AE0F-42B9-9E25-47F541DF5196", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "B23096F5-3546-41D8-BE30-8698BC0C9B42", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D7C5AF13-69FF-444F-B84A-130D7413B307", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "66A17FC6-B6AE-4915-8069-68B41F3C87E2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4C618736-1382-4515-A295-6EC67A2731EA", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "BC0AD5A8-768E-4747-AD89-B924D369565E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "105CCE4B-D8F9-43EA-9089-CEE16A410751", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "0A4F6758-0B36-4546-A7A7-A4C71B63772E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "12A613F7-4EA4-40FF-931F-EF3C477300DA", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "4B048552-A26D-419E-9EEA-9AFD9457B70B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "BA4B198A-8288-459D-9586-CD402DE23023", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "D972823A-1128-4222-8910-9CA3D38B472F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "869AD837-79B1-4F76-947B-7DCAD172BDC0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "5C152EB8-A13A-4F16-994A-B6D93A017CC3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "9FE49F2D-B904-4E48-AAFD-669141B570F6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "729F784C-9AC0-4231-A75A-1FA8373FA31F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "FA61AC05-061D-4EE7-BFEF-568F30B9B883", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "FDE42199-9152-41A3-BE56-E6789315CF28", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "040F990F-F3C2-46EF-9E40-FD136A19575F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B37490B0-A214-4A62-9B67-934048921C1E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "3D7B9F45-5749-4F36-961D-6C5D650ADA07", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "F544593D-368B-4EC1-8448-8C2BA1301216", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "5F902732-9944-4821-BCFB-9937D1301FF6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "3EECF743-25E8-4483-AA68-B304B38A9290", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "2F557157-AAD6-4601-84C2-2F8574F23683", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A8EC6926-258F-4F5C-88D2-33FE363340DB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "97E283EF-A950-40E7-91C7-839203A333A5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "B5B130C2-28B8-464C-981C-B5662B4B4309", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "79407355-4181-4082-A661-C27734D95363", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "8989C7D4-5246-443E-B6E4-8E91462B2E96", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "B47671A7-A8DB-4DA2-9076-78708C7F1C42", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2D9CF819-E06C-4EAA-85B3-AC40E039D485", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4AF727E5-7849-4980-8AA5-7469FD52DF86", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "5052CB07-626A-46C4-8966-B8C9325A3BB3", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B28FB484-526A-437E-80E3-B62F54F1BEF6", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "81CE70BF-EBBE-4CD7-999C-25662670EFCB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "221EB3AE-1420-46F8-9EAD-1914503B0435", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "5F9A416C-277F-44B0-A74C-263CB0C37D03", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "FA858127-69A0-4280-80A8-65E0778A90AD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "A35D0B0C-695D-4274-8B9E-69ED20B62585", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "EA400339-123F-494A-8CD8-7232281E7D29", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "C8E943A5-E35C-4CFA-8998-A74385C8740B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8E4F0084-91A5-4D7E-971B-9DB979849594", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "36EEF9EB-91EF-4697-A963-7C8F955778EC", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "7BB0B884-C99A-4854-992F-8588840CC296", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "04BA4916-5693-4915-B4D7-29D97FA02474", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "DC588CE7-1F9D-43EF-A478-C23C8D909685", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "2DE08529-E210-48C1-A7C3-D2D316902A40", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "4D184A8F-963A-4730-AED4-1994EEA91702", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "16DAC92E-141C-4923-96F5-2620F60E763A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "8104E528-ED7D-451E-8834-057295A7FF49", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4). El cliente SmartVNC presenta un fallo al manejar una excepción apropiadamente si el proceso de ejecución del programa es modificado después de enviar un paquete desde el servidor, lo que podría resultar en una condición de Denegación de Servicio", }, ], id: "CVE-2021-25662", lastModified: "2024-11-21T05:55:14.660", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "PARTIAL", baseScore: 5, confidentialityImpact: "NONE", integrityImpact: "NONE", vectorString: "AV:N/AC:L/Au:N/C:N/I:N/A:P", version: "2.0", }, exploitabilityScore: 10, impactScore: 2.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2021-05-12T14:15:11.343", references: [ { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-755", }, ], source: "productcert@siemens.com", type: "Primary", }, ], }
Vulnerability from fkie_nvd
Published
2018-12-13 16:29
Modified
2024-11-21 03:48
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/105922 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/105922 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_hmi_comfort_panels_firmware | * | |
siemens | simatic_hmi_comfort_panels | - | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_\(tia_portal\) | * | |
siemens | simatic_wincc_runtime | * | |
siemens | simatic_wincc_runtime | * | |
siemens | simatic_hmi_tp_firmware | * | |
siemens | simatic_hmi_tp | - | |
siemens | simatic_hmi_mp_firmware | * | |
siemens | simatic_hmi_mp | - | |
siemens | simatic_hmi_op_firmware | * | |
siemens | simatic_hmi_op | - |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "3AD9AEE0-437E-45C7-BA3C-696628FA6883", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "C6D3259C-2DAF-4136-BAC3-28B234329E27", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "F4830E0D-0128-4E5B-AB81-2B238471AE4B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "1D090C01-A7A7-43C2-842F-50951D75B57A", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CE04B9B4-EFFF-447D-9D98-80EE43E926E9", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8B1F081F-E97A-445B-B6D5-E0AEFA3360C1", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7027573E-5E1E-4750-98AD-AC82DC5C1708", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0B26872E-A514-4CD7-98C9-2F8B6FD3DEEB", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:*:*:*:*", matchCriteriaId: "775A5747-AB92-4E27-9A74-7DF5368A5BA9", versionEndIncluding: "15.0", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*", matchCriteriaId: "5D1FBC31-3165-4057-A615-536D73A75311", versionEndIncluding: "15.0", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*", matchCriteriaId: "92C7789F-1646-485A-9889-5AD81B5F1105", versionEndIncluding: "15.0", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "983886F3-5B11-4AC3-A4D9-C2816F9A37DF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*", matchCriteriaId: "EE8F082D-04C4-4A3E-B3D1-6C2914C2917E", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A2271FBE-FF50-4614-A4A5-BBAB800F5FBD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*", matchCriteriaId: "68C30B3C-90EF-4244-9235-D87A421850DC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "217870AC-9EB0-4BDE-A2E2-381055B8E69C", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*", matchCriteriaId: "A17F4CDF-5367-4343-AA1E-0C452495E598", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels 4\" - 22\" (todas las versiones anteriores a V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" 15\" (todas las versiones anteriores a V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (todas las versiones anteriores a V15 Update 4), SIMATIC WinCC Runtime Advanced (todas las versiones anteriores a V15 Update 4), SIMATIC WinCC Runtime Professional (todas las versiones anteriores a V15 Update 4), SIMATIC WinCC (TIA Portal) (todas las versiones anteriores a V15 Update 4) y SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (todas las versiones). Una vulnerabilidad de salto de directorio podría permitir la descarga de archivos arbitrarios desde el dispositivo. Esta vulnerabilidad de seguridad podría ser explotada por atacantes con acceso de red al servidor web integrado. No se requiere interacción o autenticación del usuario para explotar esta vulnerabilidad. La vulnerabilidad impacta la confidencialidad del dispositivo. En el momento de la publicación del aviso, no se conoce ninguna explotación pública de la vulnerabilidad de seguridad.", }, ], id: "CVE-2018-13812", lastModified: "2024-11-21T03:48:07.190", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "NONE", baseScore: 5, confidentialityImpact: "PARTIAL", integrityImpact: "NONE", vectorString: "AV:N/AC:L/Au:N/C:P/I:N/A:N", version: "2.0", }, exploitabilityScore: 10, impactScore: 2.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV30: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "NONE", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "HIGH", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", version: "3.0", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2018-12-13T16:29:00.290", references: [ { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securityfocus.com/bid/105922", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securityfocus.com/bid/105922", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-22", }, ], source: "productcert@siemens.com", type: "Secondary", }, { description: [ { lang: "en", value: "CWE-22", }, ], source: "nvd@nist.gov", type: "Primary", }, ], }
Vulnerability from fkie_nvd
Published
2019-05-14 20:29
Modified
2024-11-21 04:46
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/108412 | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf | Vendor Advisory | |
productcert@siemens.com | https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | ||
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/108412 | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_hmi_comfort_panels_firmware | * | |
siemens | simatic_hmi_comfort_panels | - | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_\(tia_portal\) | * | |
siemens | simatic_wincc_runtime | * | |
siemens | simatic_wincc_runtime | * | |
siemens | simatic_hmi_tp_firmware | * | |
siemens | simatic_hmi_tp | - | |
siemens | simatic_hmi_mp_firmware | * | |
siemens | simatic_hmi_mp | - | |
siemens | simatic_hmi_op_firmware | * | |
siemens | simatic_hmi_op | - |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "865FD012-F390-4BB8-B14F-533840B95512", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7299F88D-8885-4871-93E1-CBEFD3156B15", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "F4830E0D-0128-4E5B-AB81-2B238471AE4B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A8EC6926-258F-4F5C-88D2-33FE363340DB", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2D9CF819-E06C-4EAA-85B3-AC40E039D485", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B28FB484-526A-437E-80E3-B62F54F1BEF6", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8E4F0084-91A5-4D7E-971B-9DB979849594", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:*:*:*:*", matchCriteriaId: "82389DAA-8D03-4806-AF86-87A1627A972F", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*", matchCriteriaId: "C24C17B5-C379-4FD1-BA9F-38B2A329F254", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*", matchCriteriaId: "24939BB3-7D99-4812-9EF8-65FE1FC9CCD8", versionEndExcluding: "15.1", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "983886F3-5B11-4AC3-A4D9-C2816F9A37DF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*", matchCriteriaId: "EE8F082D-04C4-4A3E-B3D1-6C2914C2917E", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A2271FBE-FF50-4614-A4A5-BBAB800F5FBD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*", matchCriteriaId: "68C30B3C-90EF-4244-9235-D87A421850DC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "217870AC-9EB0-4BDE-A2E2-381055B8E69C", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*", matchCriteriaId: "A17F4CDF-5367-4343-AA1E-0C452495E598", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.", }, { lang: "es", value: "Ha sido identificada una vulnerabilidad en SIMATIC HMI Comfort Panels 4\" - 22\" (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC WinCC Runtime Professional (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC WinCC (TIA Portal) (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (Todas las versiones). El servidor web integrado podría permitir ataques de Cross-Site Scripting (XSS) si un atacante puede modificar partes particulares de la configuración del dispositivo por medio de SNMP. La vulnerabilidad de la seguridad podría ser explotada por un atacante con acceso de red al sistema afectado. La explotación con éxito requiere privilegios del sistema e interacción del usuario. Un atacante podría utilizar la vulnerabilidad para comprometer la confidencialidad y la integridad del sistema afectado. En la etapa de publicación de este aviso de seguridad no se conoce ninguna explotación pública.", }, ], id: "CVE-2019-6577", lastModified: "2024-11-21T04:46:44.267", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "LOW", cvssData: { accessComplexity: "MEDIUM", accessVector: "NETWORK", authentication: "SINGLE", availabilityImpact: "NONE", baseScore: 3.5, confidentialityImpact: "NONE", integrityImpact: "PARTIAL", vectorString: "AV:N/AC:M/Au:S/C:N/I:P/A:N", version: "2.0", }, exploitabilityScore: 6.8, impactScore: 2.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: true, }, ], cvssMetricV30: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "NONE", baseScore: 5.4, baseSeverity: "MEDIUM", confidentialityImpact: "LOW", integrityImpact: "LOW", privilegesRequired: "LOW", scope: "CHANGED", userInteraction: "REQUIRED", vectorString: "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", version: "3.0", }, exploitabilityScore: 2.3, impactScore: 2.7, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2019-05-14T20:29:04.623", references: [ { source: "productcert@siemens.com", url: "http://www.securityfocus.com/bid/108412", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { source: "productcert@siemens.com", url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "http://www.securityfocus.com/bid/108412", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-80", }, ], source: "productcert@siemens.com", type: "Secondary", }, { description: [ { lang: "en", value: "CWE-79", }, ], source: "nvd@nist.gov", type: "Primary", }, ], }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | sinamics_sh150_firmware | * | |
siemens | sinamics_sh150 | - | |
siemens | sinamics_sm150i_firmware | * | |
siemens | sinamics_sm150i | - | |
siemens | sinamics_gh150_firmware | * | |
siemens | sinamics_gh150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | * | |
siemens | sinamics_sm120 | - | |
siemens | sinamics_sm150_firmware | * | |
siemens | sinamics_sm150 | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "C0891D85-C5F4-4CD2-8EFA-84356CE36654", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", matchCriteriaId: "E0005A53-33AD-47AF-B172-CAF423DE213F", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", matchCriteriaId: "9696B0D9-5A66-4747-9437-791EAC150DDA", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", matchCriteriaId: "F6AC2BA5-1668-4B71-8812-925AC6554F5A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", matchCriteriaId: "047D0868-3DA6-41CF-A6F9-D15668D536FB", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", matchCriteriaId: "EBC7AA8D-9046-4111-A263-38343997F984", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D6067521-A21D-4B2A-AFB2-2E033F66B63E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", matchCriteriaId: "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4BF9157D-0089-4569-9AA1-4DEE94140D25", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", matchCriteriaId: "BF977545-395A-4C34-BB22-A1047B5B6E85", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4D780400-0AA8-449C-B754-7167CA878D3D", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", matchCriteriaId: "DED7F33B-D475-4232-8683-48554A6729F7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "61CD50EE-6C46-445E-8D46-82768CAAC305", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", matchCriteriaId: "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E032554B-7F51-4482-AF55-743FFB5AC352", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", matchCriteriaId: "C6619B0F-7CDC-40A6-89B2-C6067AF45214", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CFFE3048-EEB0-48A0-BED0-8647284B022B", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", matchCriteriaId: "444DD77F-DB65-4766-A89D-7A679B4CA1E1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", matchCriteriaId: "2AE231E2-2B2B-407A-BF7A-9EA35F394229", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "244D9B27-649C-4983-B374-6A8774771AC5", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "A2530BB3-484C-4D24-82F6-15967C8B7B32", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "B5A1FACE-E693-4FDA-944D-0B7F500007B6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "6A673BD0-96B5-48CA-B060-A5D01687A764", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", matchCriteriaId: "C33A64DD-22A2-4260-929F-7595CD037823", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "9756D206-E295-4B0C-B159-F9A953342E37", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "F2D6D924-858A-4542-BCD0-A5631F941039", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "309E4D56-6D39-4E8F-8312-FF178B721392", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "EDB63639-3101-4F60-8193-EF219D99C128", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6C6C72B0-17D7-491E-816A-AF855166A90B", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D14DE5C7-318A-4D08-BB39-1E43F624816A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "21FB0305-DF87-42FF-BACA-E8255EA74AA9", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "BAA5B299-A45A-4918-AB8F-03A476CEDA17", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "0C29FD64-C041-4269-BC52-8F91321BC247", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "845C78A9-AE0F-42B9-9E25-47F541DF5196", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "B23096F5-3546-41D8-BE30-8698BC0C9B42", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D7C5AF13-69FF-444F-B84A-130D7413B307", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "66A17FC6-B6AE-4915-8069-68B41F3C87E2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4C618736-1382-4515-A295-6EC67A2731EA", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "BC0AD5A8-768E-4747-AD89-B924D369565E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "105CCE4B-D8F9-43EA-9089-CEE16A410751", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "0A4F6758-0B36-4546-A7A7-A4C71B63772E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "12A613F7-4EA4-40FF-931F-EF3C477300DA", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "4B048552-A26D-419E-9EEA-9AFD9457B70B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "BA4B198A-8288-459D-9586-CD402DE23023", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "D972823A-1128-4222-8910-9CA3D38B472F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "869AD837-79B1-4F76-947B-7DCAD172BDC0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "5C152EB8-A13A-4F16-994A-B6D93A017CC3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "9FE49F2D-B904-4E48-AAFD-669141B570F6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "729F784C-9AC0-4231-A75A-1FA8373FA31F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "FA61AC05-061D-4EE7-BFEF-568F30B9B883", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "FDE42199-9152-41A3-BE56-E6789315CF28", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "040F990F-F3C2-46EF-9E40-FD136A19575F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B37490B0-A214-4A62-9B67-934048921C1E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "3D7B9F45-5749-4F36-961D-6C5D650ADA07", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "F544593D-368B-4EC1-8448-8C2BA1301216", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "5F902732-9944-4821-BCFB-9937D1301FF6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "3EECF743-25E8-4483-AA68-B304B38A9290", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "2F557157-AAD6-4601-84C2-2F8574F23683", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A8EC6926-258F-4F5C-88D2-33FE363340DB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "97E283EF-A950-40E7-91C7-839203A333A5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "B5B130C2-28B8-464C-981C-B5662B4B4309", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "79407355-4181-4082-A661-C27734D95363", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "8989C7D4-5246-443E-B6E4-8E91462B2E96", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "B47671A7-A8DB-4DA2-9076-78708C7F1C42", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2D9CF819-E06C-4EAA-85B3-AC40E039D485", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4AF727E5-7849-4980-8AA5-7469FD52DF86", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "5052CB07-626A-46C4-8966-B8C9325A3BB3", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B28FB484-526A-437E-80E3-B62F54F1BEF6", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "81CE70BF-EBBE-4CD7-999C-25662670EFCB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "221EB3AE-1420-46F8-9EAD-1914503B0435", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "5F9A416C-277F-44B0-A74C-263CB0C37D03", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "FA858127-69A0-4280-80A8-65E0778A90AD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "A35D0B0C-695D-4274-8B9E-69ED20B62585", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "EA400339-123F-494A-8CD8-7232281E7D29", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "C8E943A5-E35C-4CFA-8998-A74385C8740B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8E4F0084-91A5-4D7E-971B-9DB979849594", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "36EEF9EB-91EF-4697-A963-7C8F955778EC", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "7BB0B884-C99A-4854-992F-8588840CC296", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "04BA4916-5693-4915-B4D7-29D97FA02474", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "DC588CE7-1F9D-43EF-A478-C23C8D909685", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "2DE08529-E210-48C1-A7C3-D2D316902A40", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "4D184A8F-963A-4730-AED4-1994EEA91702", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "16DAC92E-141C-4923-96F5-2620F60E763A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "8104E528-ED7D-451E-8834-057295A7FF49", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con opción X30) (Todas las versiones), SINAMICS GM150 (con opción X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). Un atacante remoto podría enviar paquetes especialmente diseñados al manejador de diseño de dispositivos SmartVNC en el lado del cliente, lo que podría influir en la cantidad de recursos consumidos y dar lugar a una condición de denegación de servicio (bucle infinito)", }, ], id: "CVE-2021-27385", lastModified: "2024-11-21T05:57:53.380", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "PARTIAL", baseScore: 5, confidentialityImpact: "NONE", integrityImpact: "NONE", vectorString: "AV:N/AC:L/Au:N/C:N/I:N/A:P", version: "2.0", }, exploitabilityScore: 10, impactScore: 2.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2021-05-12T14:15:11.727", references: [ { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-400", }, ], source: "productcert@siemens.com", type: "Secondary", }, { description: [ { lang: "en", value: "CWE-835", }, ], source: "nvd@nist.gov", type: "Primary", }, ], }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | simatic_wincc_runtime_advanced | 16 | |
siemens | sinamics_sh150_firmware | * | |
siemens | sinamics_sh150 | - | |
siemens | sinamics_sm150i_firmware | * | |
siemens | sinamics_sm150i | - | |
siemens | sinamics_gh150_firmware | * | |
siemens | sinamics_gh150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | * | |
siemens | sinamics_sm120 | - | |
siemens | sinamics_sm150_firmware | * | |
siemens | sinamics_sm150 | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 16 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 16 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 16 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | 15.1 | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 | |
siemens | simatic_wincc_runtime_advanced | 15.1 |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "C0891D85-C5F4-4CD2-8EFA-84356CE36654", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", matchCriteriaId: "E0005A53-33AD-47AF-B172-CAF423DE213F", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", matchCriteriaId: "9696B0D9-5A66-4747-9437-791EAC150DDA", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", matchCriteriaId: "F6AC2BA5-1668-4B71-8812-925AC6554F5A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", matchCriteriaId: "047D0868-3DA6-41CF-A6F9-D15668D536FB", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", matchCriteriaId: "EBC7AA8D-9046-4111-A263-38343997F984", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "D6067521-A21D-4B2A-AFB2-2E033F66B63E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", matchCriteriaId: "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4BF9157D-0089-4569-9AA1-4DEE94140D25", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", matchCriteriaId: "BF977545-395A-4C34-BB22-A1047B5B6E85", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4D780400-0AA8-449C-B754-7167CA878D3D", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", matchCriteriaId: "DED7F33B-D475-4232-8683-48554A6729F7", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "61CD50EE-6C46-445E-8D46-82768CAAC305", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", matchCriteriaId: "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E032554B-7F51-4482-AF55-743FFB5AC352", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", matchCriteriaId: "C6619B0F-7CDC-40A6-89B2-C6067AF45214", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "CFFE3048-EEB0-48A0-BED0-8647284B022B", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", matchCriteriaId: "444DD77F-DB65-4766-A89D-7A679B4CA1E1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", matchCriteriaId: "2AE231E2-2B2B-407A-BF7A-9EA35F394229", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "244D9B27-649C-4983-B374-6A8774771AC5", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "A2530BB3-484C-4D24-82F6-15967C8B7B32", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "B5A1FACE-E693-4FDA-944D-0B7F500007B6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "6A673BD0-96B5-48CA-B060-A5D01687A764", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", matchCriteriaId: "C33A64DD-22A2-4260-929F-7595CD037823", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "9756D206-E295-4B0C-B159-F9A953342E37", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "F2D6D924-858A-4542-BCD0-A5631F941039", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "309E4D56-6D39-4E8F-8312-FF178B721392", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "EDB63639-3101-4F60-8193-EF219D99C128", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6C6C72B0-17D7-491E-816A-AF855166A90B", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D14DE5C7-318A-4D08-BB39-1E43F624816A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "21FB0305-DF87-42FF-BACA-E8255EA74AA9", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "BAA5B299-A45A-4918-AB8F-03A476CEDA17", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "0C29FD64-C041-4269-BC52-8F91321BC247", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "845C78A9-AE0F-42B9-9E25-47F541DF5196", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "B23096F5-3546-41D8-BE30-8698BC0C9B42", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "D7C5AF13-69FF-444F-B84A-130D7413B307", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "66A17FC6-B6AE-4915-8069-68B41F3C87E2", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "4C618736-1382-4515-A295-6EC67A2731EA", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "BC0AD5A8-768E-4747-AD89-B924D369565E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "105CCE4B-D8F9-43EA-9089-CEE16A410751", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "0A4F6758-0B36-4546-A7A7-A4C71B63772E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "12A613F7-4EA4-40FF-931F-EF3C477300DA", versionEndExcluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", matchCriteriaId: "4B048552-A26D-419E-9EEA-9AFD9457B70B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", matchCriteriaId: "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", matchCriteriaId: "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", matchCriteriaId: "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "BA4B198A-8288-459D-9586-CD402DE23023", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "D972823A-1128-4222-8910-9CA3D38B472F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "869AD837-79B1-4F76-947B-7DCAD172BDC0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "5C152EB8-A13A-4F16-994A-B6D93A017CC3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "B531FDD4-2796-4FE9-9F94-E9D461C7C528", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "9FE49F2D-B904-4E48-AAFD-669141B570F6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "729F784C-9AC0-4231-A75A-1FA8373FA31F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "FA61AC05-061D-4EE7-BFEF-568F30B9B883", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "FDE42199-9152-41A3-BE56-E6789315CF28", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "040F990F-F3C2-46EF-9E40-FD136A19575F", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B37490B0-A214-4A62-9B67-934048921C1E", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "3D7B9F45-5749-4F36-961D-6C5D650ADA07", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "F544593D-368B-4EC1-8448-8C2BA1301216", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "D63658BB-2364-4DE5-904B-2367B70294AC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "5F902732-9944-4821-BCFB-9937D1301FF6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "3EECF743-25E8-4483-AA68-B304B38A9290", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "2F557157-AAD6-4601-84C2-2F8574F23683", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", matchCriteriaId: "DFDC8157-7EA3-4BC4-82C1-06A307996F45", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A8EC6926-258F-4F5C-88D2-33FE363340DB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "97E283EF-A950-40E7-91C7-839203A333A5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "B5B130C2-28B8-464C-981C-B5662B4B4309", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "79407355-4181-4082-A661-C27734D95363", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "8989C7D4-5246-443E-B6E4-8E91462B2E96", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "B47671A7-A8DB-4DA2-9076-78708C7F1C42", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2D9CF819-E06C-4EAA-85B3-AC40E039D485", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4AF727E5-7849-4980-8AA5-7469FD52DF86", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "5052CB07-626A-46C4-8966-B8C9325A3BB3", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B28FB484-526A-437E-80E3-B62F54F1BEF6", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "81CE70BF-EBBE-4CD7-999C-25662670EFCB", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "221EB3AE-1420-46F8-9EAD-1914503B0435", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "5F9A416C-277F-44B0-A74C-263CB0C37D03", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "FA858127-69A0-4280-80A8-65E0778A90AD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "A35D0B0C-695D-4274-8B9E-69ED20B62585", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "EA400339-123F-494A-8CD8-7232281E7D29", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "C8E943A5-E35C-4CFA-8998-A74385C8740B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8E4F0084-91A5-4D7E-971B-9DB979849594", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "36EEF9EB-91EF-4697-A963-7C8F955778EC", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "7BB0B884-C99A-4854-992F-8588840CC296", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "04BA4916-5693-4915-B4D7-29D97FA02474", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "DC588CE7-1F9D-43EF-A478-C23C8D909685", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "2DE08529-E210-48C1-A7C3-D2D316902A40", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", matchCriteriaId: "4D184A8F-963A-4730-AED4-1994EEA91702", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", matchCriteriaId: "16DAC92E-141C-4923-96F5-2620F60E763A", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", matchCriteriaId: "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", matchCriteriaId: "8104E528-ED7D-451E-8834-057295A7FF49", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", matchCriteriaId: "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones anteriores), SINAMICS GL150 (with option X30) (Todas las versiones anteriores), SINAMICS GM150 (with option X30) (Todas las versiones anteriores), SINAMICS SH150 (Todas las versiones anteriores), SINAMICS SL150 (Todas las versiones anteriores), SINAMICS SM120 (Todas las versiones anteriores), SINAMICS SM150 (Todas las versiones anteriores), SINAMICS SM150i (Todas las versiones anteriores). SmartVNC tiene una vulnerabilidad de acceso a memoria fuera de límites en el manejador de diseño del dispositivo, representado por un flujo de datos binarios en el lado del cliente, que potencialmente puede resultar en la ejecución de código", }, ], id: "CVE-2021-27384", lastModified: "2024-11-21T05:57:53.230", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "HIGH", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "PARTIAL", baseScore: 7.5, confidentialityImpact: "PARTIAL", integrityImpact: "PARTIAL", vectorString: "AV:N/AC:L/Au:N/C:P/I:P/A:P", version: "2.0", }, exploitabilityScore: 10, impactScore: 6.4, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 9.8, baseSeverity: "CRITICAL", confidentialityImpact: "HIGH", integrityImpact: "HIGH", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 5.9, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2021-05-12T14:15:11.677", references: [ { source: "productcert@siemens.com", tags: [ "Patch", "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { source: "productcert@siemens.com", tags: [ "Patch", "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Patch", "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Patch", "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-788", }, ], source: "productcert@siemens.com", type: "Primary", }, ], }
Vulnerability from fkie_nvd
Published
2019-04-17 14:29
Modified
2024-11-21 04:46
Severity ?
Summary
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_cp443-1_opc_ua_firmware | * | |
siemens | simatic_cp443-1_opc_ua | - | |
siemens | simatic_et_200_open_controller_cpu_1515sp_pc2_firmware | * | |
siemens | simatic_et_200_open_controller_cpu_1515sp_pc2 | - | |
siemens | simatic_ipc_diagmonitor_firmware | * | |
siemens | simatic_ipc_diagmonitor | - | |
siemens | simatic_net_pc_software_firmware | * | |
siemens | simatic_net_pc_software | - | |
siemens | simatic_rf188c_firmware | * | |
siemens | simatic_rf188c | - | |
siemens | simatic_rf600r_firmware | * | |
siemens | simatic_rf600r | - | |
siemens | simatic_s7-1500_firmware | * | |
siemens | simatic_s7-1500 | - | |
siemens | opc_unified_architecture | * | |
siemens | simatic_s7-1500_software_controller | * | |
siemens | simatic_wincc_oa | * | |
siemens | simatic_wincc_runtime_advanced | * | |
siemens | simatic_wincc_runtime_comfort | * | |
siemens | simatic_wincc_runtime_hsp_comfort | * | |
siemens | simatic_wincc_runtime_mobile | * | |
siemens | sinec-nms | * | |
siemens | sinec-nms | 1.0 | |
siemens | sinema_server | * | |
siemens | sinumerik_opc_ua_server | * | |
siemens | telecontrol_server_basic | * | |
siemens | simatic_s7-1500f_firmware | * | |
siemens | simatic_s7-1500f | - | |
siemens | simatic_s7-1500s_firmware | * | |
siemens | simatic_s7-1500s | - | |
siemens | simatic_s7-1500t_firmware | * | |
siemens | simatic_s7-1500t | - | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | 15.1 | |
siemens | simatic_hmi_comfort_outdoor_panels | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | 15.1 | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_cp443-1_opc_ua_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "5D0780D2-8892-490E-9C38-6D1516EBCA76", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_cp443-1_opc_ua:-:*:*:*:*:*:*:*", matchCriteriaId: "47272AD2-1D05-419E-A6BE-8836DF69FF82", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "DFB5AE88-04E5-467E-85E5-D3C0DDA2B21F", versionEndExcluding: "2.7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*", matchCriteriaId: "AF0944C4-8FD7-4B00-85B7-6DB430EAA884", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_ipc_diagmonitor_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "91371CD0-EBDF-43C5-A262-A46E1C343716", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*", matchCriteriaId: "A5E06833-4C26-40AC-B6CF-F7D1322462D6", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_net_pc_software_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "77022802-113F-42E7-8FBF-C47BB50E8DA7", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_net_pc_software:-:*:*:*:*:*:*:*", matchCriteriaId: "E7A00F5A-9B28-45FF-8549-290302939DFD", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7F3D41E9-58B3-4251-8710-A8C4A24ABBD3", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*", matchCriteriaId: "E21F9909-8D80-40BE-81E0-6ED7FE140A3A", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_rf600r_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "9523EC09-36C9-41E1-A485-C75819A2DB72", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_rf600r:-:*:*:*:*:*:*:*", matchCriteriaId: "EFA55275-691D-4269-93E4-C559C89E3FA3", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "065D2218-EA10-410E-A49A-C9A259469421", versionEndIncluding: "2.5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*", matchCriteriaId: "30DDEA9B-E1BF-4572-8E12-D13C54603E77", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:opc_unified_architecture:*:*:*:*:*:*:*:*", matchCriteriaId: "6230C5B0-2F36-4C94-BA28-D36170952423", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*", matchCriteriaId: "054D17CD-74AF-473E-A3BC-7B69DFB1C04B", versionEndIncluding: "2.5", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_oa:*:*:*:*:*:*:*:*", matchCriteriaId: "1B74D88E-E8D7-4AA9-8B54-CC833E26CEB4", versionEndExcluding: "3.15-p018", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", matchCriteriaId: "79EE15DC-74D3-4551-AAD0-EA0CB600DA76", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_comfort:*:*:*:*:*:*:*:*", matchCriteriaId: "C9AE946B-D532-4CEB-B109-C8B951B61E49", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_hsp_comfort:*:*:*:*:*:*:*:*", matchCriteriaId: "49D722B2-948B-4F11-AD36-E1378BB40403", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime_mobile:*:*:*:*:*:*:*:*", matchCriteriaId: "455411C4-037C-47BF-9BD6-AC7F9C2D30F1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinec-nms:*:*:*:*:*:*:*:*", matchCriteriaId: "8ED63145-9082-4346-871B-DF0A6F91E7F0", versionEndExcluding: "1.0", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinec-nms:1.0:-:*:*:*:*:*:*", matchCriteriaId: "1F6F05DC-0FBA-4D25-A2E6-06D873B3DFAA", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinema_server:*:*:*:*:*:*:*:*", matchCriteriaId: "C55DA617-6333-40DA-AB7D-EE49A453E143", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:*", matchCriteriaId: "5E31B88B-E743-4DFD-996B-154F7F48C510", versionEndExcluding: "2.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*", matchCriteriaId: "D2ECBEF2-9B1A-49F8-9850-0AF09BF71ED7", versionEndExcluding: "3.1.1", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "58CCDA0F-F657-4AF8-BE53-A3993C0280B3", versionEndIncluding: "2.5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500f:-:*:*:*:*:*:*:*", matchCriteriaId: "A255BC06-2776-4111-A525-76B17371B295", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500s_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "F3F162D0-998E-4EC9-BA59-D9B47B07EF69", versionEndIncluding: "2.5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500s:-:*:*:*:*:*:*:*", matchCriteriaId: "C1752A2A-0034-4E00-AAC6-FA15345D7A41", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_s7-1500t_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "C47ADAD6-2DDE-49EF-864B-CC9448399E7B", versionEndIncluding: "2.5", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_s7-1500t:-:*:*:*:*:*:*:*", matchCriteriaId: "741B2C38-174C-49DF-98D8-F7D6F49D1CE5", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "7299F88D-8885-4871-93E1-CBEFD3156B15", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "F18EA7BD-47D0-4367-8F18-C89239B201E3", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_1:*:*:*:*:*:*", matchCriteriaId: "DE71784C-012F-40EC-82E2-3BE8589F00DC", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_2:*:*:*:*:*:*", matchCriteriaId: "C5A35FDE-C76F-430E-BD15-373F9F30FED5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_3:*:*:*:*:*:*", matchCriteriaId: "37A6344F-CB58-4CFA-A971-395BFB3FF02B", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "F4830E0D-0128-4E5B-AB81-2B238471AE4B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A8EC6926-258F-4F5C-88D2-33FE363340DB", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "97E283EF-A950-40E7-91C7-839203A333A5", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_1:*:*:*:*:*:*", matchCriteriaId: "E949961E-320A-4E25-A0CA-5EBC7DA0AD9D", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_2:*:*:*:*:*:*", matchCriteriaId: "A390DCB7-4511-4931-A34B-BF6A9B84370D", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_3:*:*:*:*:*:*", matchCriteriaId: "FF5136A8-130C-4121-A250-B4DE5883239E", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_1:*:*:*:*:*:*", matchCriteriaId: "862B1996-202B-42DF-A7DA-D01CD43C4AB3", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_2:*:*:*:*:*:*", matchCriteriaId: "7AFD3E4C-7125-4FB5-991F-76A31AD61BD9", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_3:*:*:*:*:*:*", matchCriteriaId: "71172F82-C9B6-4DEC-ADCC-F455E72936CA", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B28FB484-526A-437E-80E3-B62F54F1BEF6", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_1:*:*:*:*:*:*", matchCriteriaId: "A8CA985F-3678-46F4-BE2E-BDBCCD1BC0FE", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_2:*:*:*:*:*:*", matchCriteriaId: "1A28CC05-0CEA-4221-83CE-4029726F60E0", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_3:*:*:*:*:*:*", matchCriteriaId: "5D612CB7-45A0-44AC-BB96-12AFE2B14CE8", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "2D9CF819-E06C-4EAA-85B3-AC40E039D485", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "4AF727E5-7849-4980-8AA5-7469FD52DF86", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_1:*:*:*:*:*:*", matchCriteriaId: "7B0FAB4F-7D95-4FC0-AF59-CCEDC6E22DC3", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_2:*:*:*:*:*:*", matchCriteriaId: "5C925AE3-7262-4DDD-803D-D871A66CD2B2", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_3:*:*:*:*:*:*", matchCriteriaId: "E64DEED6-7E6F-4E79-BA4D-2B2E43B2B97D", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8E4F0084-91A5-4D7E-971B-9DB979849594", versionEndExcluding: "15.1", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", matchCriteriaId: "36EEF9EB-91EF-4697-A963-7C8F955778EC", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_1:*:*:*:*:*:*", matchCriteriaId: "9429BA23-CB76-4574-B7F8-530882CF704A", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_2:*:*:*:*:*:*", matchCriteriaId: "3794C871-098D-428F-89EA-ADDEFD4E4A86", vulnerable: true, }, { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_3:*:*:*:*:*:*", matchCriteriaId: "386F501D-5C7D-4336-A39D-31B12C5BCB56", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en SIMATIC CP 443-1 OPC UA (todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incluidas las variantes SIPLUS) (todas las versiones anteriores a V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incluidas las variantes SIPLUS) (todas las versiones anteriores a V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incluidas las variantes SIPLUS) (todas las versiones anteriores a V15. 1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (Todas las versiones anteriores a V15.1 Upd 4), SIMATIC IPC DiagMonitor (Todas las versiones anteriores a V5.1. 3), SIMATIC NET PC Software V13 (Todas las versiones), SIMATIC NET PC Software V14 (Todas las versiones anteriores a V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC RF188C (Todas las versiones anteriores a V1. 1.0), familia SIMATIC RF600R (Todas las versiones anteriores a V3.2.1), familia de CPUs SIMATIC S7-1500 (incluidas las CPUs ET200 relacionadas y las variantes SIPLUS) (Todas las versiones posteriores o iguales a V2.5 anteriores a V2.6.1), SIMATIC S7-1500 Software Controller (Todas las versiones entre V2.5 (incluida) y V2.7 (excluida)), SIMATIC WinCC OA (Todas las versiones anteriores a V3. 15 P018), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a V15.1 Upd 4), SINEC NMS (Todas las versiones anteriores a V1.0 SP1), SINEMA Server (Todas las versiones anteriores a V14 SP2), SINUMERIK OPC UA Server (Todas las versiones anteriores a V2.1), TeleControl Server Basic (Todas las versiones anteriores a V3.1.1). Los paquetes de red especialmente diseñados que se envían a los dispositivos afectados en el puerto 4840/tcp podrían permitir a un atacante remoto no autenticado provocar una condición de denegación de servicio de la comunicación OPC o bloquear el dispositivo. La vulnerabilidad de seguridad podría ser explotada por un atacante con acceso a la red de los sistemas afectados. La explotación exitosa no requiere privilegios del sistema ni interacción del usuario. Un atacante podría utilizar la vulnerabilidad para comprometer la disponibilidad de la comunicación OPC", }, ], id: "CVE-2019-6575", lastModified: "2024-11-21T04:46:43.960", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "HIGH", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "COMPLETE", baseScore: 7.8, confidentialityImpact: "NONE", integrityImpact: "NONE", vectorString: "AV:N/AC:L/Au:N/C:N/I:N/A:C", version: "2.0", }, exploitabilityScore: 10, impactScore: 6.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.5, baseSeverity: "HIGH", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 3.6, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2019-04-17T14:29:03.760", references: [ { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-248", }, ], source: "productcert@siemens.com", type: "Primary", }, { description: [ { lang: "en", value: "CWE-755", }, ], source: "nvd@nist.gov", type: "Secondary", }, ], }
Vulnerability from fkie_nvd
Published
2018-12-13 16:29
Modified
2024-11-21 03:48
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/105931 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/105931 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_hmi_comfort_panels_firmware | * | |
siemens | simatic_hmi_comfort_panels | - | |
siemens | simatic_hmi_comfort_outdoor_panels_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp400f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp700f | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900 | - | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels_ktp900f | - | |
siemens | simatic_wincc_\(tia_portal\) | * | |
siemens | simatic_wincc_runtime | * | |
siemens | simatic_wincc_runtime | * | |
siemens | simatic_hmi_tp_firmware | * | |
siemens | simatic_hmi_tp | - | |
siemens | simatic_hmi_mp_firmware | * | |
siemens | simatic_hmi_mp | - | |
siemens | simatic_hmi_op_firmware | * | |
siemens | simatic_hmi_op | - |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "1E4E5DE2-34BF-4B0E-9C53-FF53255DEA72", versionEndExcluding: "14.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "8ED4BD65-A2BC-45DB-8465-1A5846916522", versionEndExcluding: "14.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", matchCriteriaId: "F4830E0D-0128-4E5B-AB81-2B238471AE4B", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A37DC20C-7FE9-42B0-BD92-01FD2F40D2A9", versionEndExcluding: "14.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", matchCriteriaId: "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "B75E3C61-A501-4B4F-98E8-E0DA53C7CD78", versionEndExcluding: "14.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", matchCriteriaId: "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "C2A9006B-1C42-4E97-9FDA-225974F5FD16", versionEndExcluding: "14.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", matchCriteriaId: "5C39166C-38CA-426F-9702-B9CA5ED6630C", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "86A4CFE5-471A-4710-8712-66B0ECDC8214", versionEndExcluding: "14.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", matchCriteriaId: "D29338CD-57BD-4734-9204-118EA53D42FB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "0A449791-25A0-46A0-A022-EACCAE506189", versionEndExcluding: "14.0", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", matchCriteriaId: "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:*:*:*:*", matchCriteriaId: "09ACCC3D-B2C3-4920-9A2D-EF4D65C60505", versionEndExcluding: "14.0", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*", matchCriteriaId: "F4E97D44-F06E-411E-ABAA-ACFB8AABEFA3", versionEndExcluding: "14.0", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*", matchCriteriaId: "3876E5D8-AA56-4262-B245-CD5915AF4CAD", versionEndExcluding: "14.0", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "983886F3-5B11-4AC3-A4D9-C2816F9A37DF", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*", matchCriteriaId: "EE8F082D-04C4-4A3E-B3D1-6C2914C2917E", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "A2271FBE-FF50-4614-A4A5-BBAB800F5FBD", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*", matchCriteriaId: "68C30B3C-90EF-4244-9235-D87A421850DC", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*", matchCriteriaId: "217870AC-9EB0-4BDE-A2E2-381055B8E69C", vulnerable: true, }, ], negate: false, operator: "OR", }, { cpeMatch: [ { criteria: "cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*", matchCriteriaId: "A17F4CDF-5367-4343-AA1E-0C452495E598", vulnerable: false, }, ], negate: false, operator: "OR", }, ], operator: "AND", }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" 15\" (todas las versiones anteriores a V14 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (todas las versiones anteriores a V14), SIMATIC WinCC Runtime Advanced (todas las versiones anteriores a V14), SIMATIC WinCC Runtime Professional (todas las versiones anteriores a V14), SIMATIC WinCC (TIA Portal) (todas las versiones anteriores a V14) y SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (todas las versiones). El servidor web integrado (puerto 80/tcp y puerto 443/tcp) de los dispositivos afectados podría permitir que un atacante inyecte cabeceras HTTP. Un atacante debe engañar a un usuario válido autenticado en el dispositivo para que haga clic en un enlace malicioso y explote esta vulnerabilidad. En el momento de la publicación del aviso, no se conoce ninguna explotación pública de la vulnerabilidad de seguridad.", }, ], id: "CVE-2018-13814", lastModified: "2024-11-21T03:48:07.560", metrics: { cvssMetricV2: [ { acInsufInfo: false, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "MEDIUM", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "PARTIAL", baseScore: 6.8, confidentialityImpact: "PARTIAL", integrityImpact: "PARTIAL", vectorString: "AV:N/AC:M/Au:N/C:P/I:P/A:P", version: "2.0", }, exploitabilityScore: 8.6, impactScore: 6.4, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: true, }, ], cvssMetricV30: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 8.8, baseSeverity: "HIGH", confidentialityImpact: "HIGH", integrityImpact: "HIGH", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "REQUIRED", vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", version: "3.0", }, exploitabilityScore: 2.8, impactScore: 5.9, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2018-12-13T16:29:00.350", references: [ { source: "productcert@siemens.com", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securityfocus.com/bid/105931", }, { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securityfocus.com/bid/105931", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-113", }, ], source: "productcert@siemens.com", type: "Secondary", }, { description: [ { lang: "en", value: "CWE-20", }, ], source: "nvd@nist.gov", type: "Primary", }, ], }