cve-2021-25662
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:11
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:11:27.535Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-755", "description": "CWE-755: Improper Handling of Exceptional Conditions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:14", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-25662", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-755: Improper Handling of Exceptional Conditions" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-25662", "datePublished": "2021-05-12T13:18:22", "dateReserved": "2021-01-21T00:00:00", "dateUpdated": "2024-08-03T20:11:27.535Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-25662\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-05-12T14:15:11.343\",\"lastModified\":\"2021-12-16T18:26:19.067\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\\\\\" \u0026 15\\\\\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\\\\\" \u0026 15\\\\\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\\\\\" - 22\\\\\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\\\\\" - 22\\\\\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\\\\\" \u0026amp; 15\\\\\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\\\\\" \u0026amp; 15\\\\\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\\\\\" - 22\\\\\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\\\\\" - 22\\\\\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4). El cliente SmartVNC presenta un fallo al manejar una excepci\u00f3n apropiadamente si el proceso de ejecuci\u00f3n del programa es modificado despu\u00e9s de enviar un paquete desde el servidor, lo que podr\u00eda resultar en una condici\u00f3n de Denegaci\u00f3n de Servicio\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-755\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"C0891D85-C5F4-4CD2-8EFA-84356CE36654\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"E0005A53-33AD-47AF-B172-CAF423DE213F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"9696B0D9-5A66-4747-9437-791EAC150DDA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"F6AC2BA5-1668-4B71-8812-925AC6554F5A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"047D0868-3DA6-41CF-A6F9-D15668D536FB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\\\\\"_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"244D9B27-649C-4983-B374-6A8774771AC5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\\\\\"_firmware:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"A2530BB3-484C-4D24-82F6-15967C8B7B32\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\\\\\"_firmware:16:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"B5A1FACE-E693-4FDA-944D-0B7F500007B6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\\\\\"_firmware:16:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"D7FB4AA4-1F48-4A25-AA21-5F867A38D23E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\\\\\"_firmware:16:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"6A673BD0-96B5-48CA-B060-A5D01687A764\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\\\\\":-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B531FDD4-2796-4FE9-9F94-E9D461C7C528\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\"_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"428B633D-55FF-4DB8-B6DD-5E4EEE52A44C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\"_firmware:16:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C33A64DD-22A2-4260-929F-7595CD037823\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\"_firmware:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"9756D206-E295-4B0C-B159-F9A953342E37\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\"_firmware:16:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\"_firmware:16:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"D43D2191-DBBD-4F7A-B02A-3DCEE46BF904\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\"_firmware:16:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"23C6AD3C-C15B-4B67-88D1-236C10BB12CF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\":-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\\\\\"_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"FEE4201E-E660-4B3E-91EC-B6A7DC35C189\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\\\\\"_firmware:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"F2D6D924-858A-4542-BCD0-A5631F941039\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\\\\\"_firmware:16:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"309E4D56-6D39-4E8F-8312-FF178B721392\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\\\\\"_firmware:16:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"EDB63639-3101-4F60-8193-EF219D99C128\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\\\\\"_firmware:16:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"4C6C83EE-3DC7-4CB3-8148-CB24A825274E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\\\\\":-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D63658BB-2364-4DE5-904B-2367B70294AC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\\\\\"_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"6C6C72B0-17D7-491E-816A-AF855166A90B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\\\\\"_firmware:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"322584EF-72C0-4032-A02B-FDFFDCCE3FDE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\\\\\"_firmware:16:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\\\\\"_firmware:16:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"D14DE5C7-318A-4D08-BB39-1E43F624816A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\\\\\"_firmware:16:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"FCDAF23F-9272-4DC5-8D46-37FAC08950CC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\\\\\":-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DFDC8157-7EA3-4BC4-82C1-06A307996F45\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"21FB0305-DF87-42FF-BACA-E8255EA74AA9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"BAA5B299-A45A-4918-AB8F-03A476CEDA17\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"0C29FD64-C041-4269-BC52-8F91321BC247\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"44F6F972-26AF-4A6E-AAD9-B30EBDF52465\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F106DEE3-4DED-46E4-9661-9D9C7B729BC0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"E57B8F3D-5E02-4F0F-9927-9D7C336EBE56\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"845C78A9-AE0F-42B9-9E25-47F541DF5196\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"B23096F5-3546-41D8-BE30-8698BC0C9B42\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"D7C5AF13-69FF-444F-B84A-130D7413B307\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"66A17FC6-B6AE-4915-8069-68B41F3C87E2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D175BC55-2EAA-4D4A-9E05-2FBB228160F1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"4C618736-1382-4515-A295-6EC67A2731EA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"BC0AD5A8-768E-4747-AD89-B924D369565E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"0AA5C3DC-E67F-4773-B32C-6B362C94BCBE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"C96C7676-9A0D-46B5-9C49-5F5CE873E2C1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5C39166C-38CA-426F-9702-B9CA5ED6630C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"105CCE4B-D8F9-43EA-9089-CEE16A410751\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"2CD3DD84-BDAC-4583-BD61-799A5F01A5B4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"0A4F6758-0B36-4546-A7A7-A4C71B63772E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D29338CD-57BD-4734-9204-118EA53D42FB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"12A613F7-4EA4-40FF-931F-EF3C477300DA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"4B048552-A26D-419E-9EEA-9AFD9457B70B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"0E4E1016-F217-4B75-83D7-F73B1C5A54F9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"EF2F6982-2C38-4F9B-87A4-AE4404197B7A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"7745AA84-BC12-4DBD-90A6-DA294EADB7BF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9E7858AB-F89E-4E50-8873-DE8F5F2A07CB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\\\\\"_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"15.1\",\"matchCriteriaId\":\"67CFFD89-1FF2-4F25-A5AB-D6FF8F721132\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\\\\\"_firmware:15.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"BA4B198A-8288-459D-9586-CD402DE23023\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\\\\\"_firmware:15.1:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\\\\\"_firmware:15.1:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"D972823A-1128-4222-8910-9CA3D38B472F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\\\\\"_firmware:15.1:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"A05007D7-3C49-4192-ABDF-FE94BA7FD1D1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\\\\\"_firmware:15.1:update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"869AD837-79B1-4F76-947B-7DCAD172BDC0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\\\\\"_firmware:15.1:update5:*:*:*:*:*:*\",\"matchCriteriaId\":\"5C152EB8-A13A-4F16-994A-B6D93A017CC3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\\\\\":-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B531FDD4-2796-4FE9-9F94-E9D461C7C528\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\"_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"15.1\",\"matchCriteriaId\":\"42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\"_firmware:15.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"553C9A57-A9D2-47F9-ABA8-042B05DE46C7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\"_firmware:15.1:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"8F5F3B33-2A82-4CDF-A678-76DE13F256D7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\"_firmware:15.1:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"9FE49F2D-B904-4E48-AAFD-669141B570F6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\"_firmware:15.1:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"729F784C-9AC0-4231-A75A-1FA8373FA31F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\"_firmware:15.1:update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"FA61AC05-061D-4EE7-BFEF-568F30B9B883\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\"_firmware:15.1:update5:*:*:*:*:*:*\",\"matchCriteriaId\":\"374BAF2F-0A32-4F1A-B838-894F9E9D3E0F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\\\\\":-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\\\\\"_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"15.1\",\"matchCriteriaId\":\"6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\\\\\"_firmware:15.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"FDE42199-9152-41A3-BE56-E6789315CF28\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\\\\\"_firmware:15.1:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"040F990F-F3C2-46EF-9E40-FD136A19575F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\\\\\"_firmware:15.1:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"748BFFBC-56BD-42EC-9B5F-0752D2A70D17\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\\\\\"_firmware:15.1:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"B37490B0-A214-4A62-9B67-934048921C1E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\\\\\"_firmware:15.1:update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"3D7B9F45-5749-4F36-961D-6C5D650ADA07\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\\\\\"_firmware:15.1:update5:*:*:*:*:*:*\",\"matchCriteriaId\":\"F544593D-368B-4EC1-8448-8C2BA1301216\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\\\\\":-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D63658BB-2364-4DE5-904B-2367B70294AC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\\\\\"_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"15.1\",\"matchCriteriaId\":\"A9D26D9F-7081-42B2-8AE4-D04E8429B88D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\\\\\"_firmware:15.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"5F902732-9944-4821-BCFB-9937D1301FF6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\\\\\"_firmware:15.1:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"B0C061AC-3E64-4667-A0E7-DD58B2E5A014\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\\\\\"_firmware:15.1:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"3EECF743-25E8-4483-AA68-B304B38A9290\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\\\\\"_firmware:15.1:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"2F557157-AAD6-4601-84C2-2F8574F23683\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\\\\\"_firmware:15.1:update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"A6BF6644-AF29-4541-9D6A-D07D0CC026F0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\\\\\"_firmware:15.1:update5:*:*:*:*:*:*\",\"matchCriteriaId\":\"C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\\\\\":-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DFDC8157-7EA3-4BC4-82C1-06A307996F45\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"15.1\",\"matchCriteriaId\":\"A8EC6926-258F-4F5C-88D2-33FE363340DB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"97E283EF-A950-40E7-91C7-839203A333A5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"B5B130C2-28B8-464C-981C-B5662B4B4309\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"79407355-4181-4082-A661-C27734D95363\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"8989C7D4-5246-443E-B6E4-8E91462B2E96\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"2BFBC5B2-B00B-4FCD-86B1-A187122035AB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*\",\"matchCriteriaId\":\"B47671A7-A8DB-4DA2-9076-78708C7F1C42\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F106DEE3-4DED-46E4-9661-9D9C7B729BC0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"15.1\",\"matchCriteriaId\":\"2D9CF819-E06C-4EAA-85B3-AC40E039D485\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"4AF727E5-7849-4980-8AA5-7469FD52DF86\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"5052CB07-626A-46C4-8966-B8C9325A3BB3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*\",\"matchCriteriaId\":\"6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D175BC55-2EAA-4D4A-9E05-2FBB228160F1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"15.1\",\"matchCriteriaId\":\"B28FB484-526A-437E-80E3-B62F54F1BEF6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"61DFC57F-0359-4B4A-A13C-067B21D3DA7B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"81CE70BF-EBBE-4CD7-999C-25662670EFCB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"034B7CFC-1234-4914-8C84-7E5BD5FB6E4D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"221EB3AE-1420-46F8-9EAD-1914503B0435\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"5F9A416C-277F-44B0-A74C-263CB0C37D03\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*\",\"matchCriteriaId\":\"FA858127-69A0-4280-80A8-65E0778A90AD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5C39166C-38CA-426F-9702-B9CA5ED6630C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"15.1\",\"matchCriteriaId\":\"66FC2264-7DDD-4BEF-9795-AC6A5A00886B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"D68363A9-D1D5-4E49-98D1-E5F8C324BC22\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"A35D0B0C-695D-4274-8B9E-69ED20B62585\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"FE9C9981-BA54-48BB-A89D-3CA06C7E17C6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"EA400339-123F-494A-8CD8-7232281E7D29\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"C8E943A5-E35C-4CFA-8998-A74385C8740B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*\",\"matchCriteriaId\":\"F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D29338CD-57BD-4734-9204-118EA53D42FB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"15.1\",\"matchCriteriaId\":\"8E4F0084-91A5-4D7E-971B-9DB979849594\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"36EEF9EB-91EF-4697-A963-7C8F955778EC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"AA0728BD-F463-456C-A6EB-9FF2FD42AA23\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"7BB0B884-C99A-4854-992F-8588840CC296\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"04BA4916-5693-4915-B4D7-29D97FA02474\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"DC588CE7-1F9D-43EF-A478-C23C8D909685\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*\",\"matchCriteriaId\":\"2DE08529-E210-48C1-A7C3-D2D316902A40\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9E7858AB-F89E-4E50-8873-DE8F5F2A07CB\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"15.1\",\"matchCriteriaId\":\"06364800-4C54-4BE4-B4AA-0CF29E4E82AA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"4FBDFA7B-504A-4F58-967F-15CAFCEB5594\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"4D184A8F-963A-4730-AED4-1994EEA91702\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"16DAC92E-141C-4923-96F5-2620F60E763A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"8104E528-ED7D-451E-8834-057295A7FF49\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*\",\"matchCriteriaId\":\"0AF02DF4-7190-4F6C-8F15-37581FFC9B86\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.