FKIE_CVE-2021-25662

Vulnerability from fkie_nvd - Published: 2021-05-12 14:15 - Updated: 2024-11-21 05:55
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.
Impacted products
Vendor Product Version
siemens simatic_wincc_runtime_advanced *
siemens simatic_wincc_runtime_advanced 16
siemens simatic_wincc_runtime_advanced 16
siemens simatic_wincc_runtime_advanced 16
siemens simatic_wincc_runtime_advanced 16
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware *
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_7\" -
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware *
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_15\" -
siemens simatic_hmi_comfort_panels_4\"_firmware *
siemens simatic_hmi_comfort_panels_4\"_firmware 16
siemens simatic_hmi_comfort_panels_4\"_firmware 16
siemens simatic_hmi_comfort_panels_4\"_firmware 16
siemens simatic_hmi_comfort_panels_4\"_firmware 16
siemens simatic_hmi_comfort_panels_4\" -
siemens simatic_hmi_comfort_panels_22\"_firmware *
siemens simatic_hmi_comfort_panels_22\"_firmware 16
siemens simatic_hmi_comfort_panels_22\"_firmware 16
siemens simatic_hmi_comfort_panels_22\"_firmware 16
siemens simatic_hmi_comfort_panels_22\"_firmware 16
siemens simatic_hmi_comfort_panels_22\" -
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp400f -
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700 -
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700f -
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900 -
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900f -
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware *
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_7\" -
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware *
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_15\" -
siemens simatic_hmi_comfort_panels_4\"_firmware *
siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
siemens simatic_hmi_comfort_panels_4\" -
siemens simatic_hmi_comfort_panels_22\"_firmware *
siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
siemens simatic_hmi_comfort_panels_22\" -
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f -
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700 -
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f -
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900 -
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f -
siemens simatic_wincc_runtime_advanced *
siemens simatic_wincc_runtime_advanced 15.1
siemens simatic_wincc_runtime_advanced 15.1
siemens simatic_wincc_runtime_advanced 15.1
siemens simatic_wincc_runtime_advanced 15.1
siemens simatic_wincc_runtime_advanced 15.1
siemens simatic_wincc_runtime_advanced 15.1

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*",
              "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4). El cliente SmartVNC presenta un fallo al manejar una excepci\u00f3n apropiadamente si el proceso de ejecuci\u00f3n del programa es modificado despu\u00e9s de enviar un paquete desde el servidor, lo que podr\u00eda resultar en una condici\u00f3n de Denegaci\u00f3n de Servicio"
    }
  ],
  "id": "CVE-2021-25662",
  "lastModified": "2024-11-21T05:55:14.660",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-12T14:15:11.343",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-755"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…