All the vulnerabilites related to siemens - simatic_pcs_neo
cve-2023-46284
Vulnerability from cvelistv5
Published
2023-12-12 11:27
Modified
2025-01-14 10:29
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Foundation |
Version: 0 < V2407 |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:45:40.702Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "lessThan": "V2407", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "lessThan": "V2312", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-14T10:29:54.329Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46284", "datePublished": "2023-12-12T11:27:15.737Z", "dateReserved": "2023-10-20T10:29:46.260Z", "dateUpdated": "2025-01-14T10:29:54.329Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-46097
Vulnerability from cvelistv5
Published
2023-11-14 11:04
Modified
2025-01-08 16:35
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly neutralize user provided inputs. This could allow an authenticated adjacent attacker to execute SQL statements in the underlying database.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | SIMATIC PCS neo |
Version: All versions < V4.1 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:39.332Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-46097", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2023-12-09T05:05:25.104413Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-08T16:35:54.086Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS neo (All versions \u003c V4.1). The PUD Manager of affected products does not properly neutralize user provided inputs. This could allow an authenticated adjacent attacker to execute SQL statements in the underlying database." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-89", "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-14T11:04:19.007Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46097", "datePublished": "2023-11-14T11:04:19.007Z", "dateReserved": "2023-10-16T11:24:12.686Z", "dateUpdated": "2025-01-08T16:35:54.086Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-7580
Vulnerability from cvelistv5
Published
2020-06-10 00:00
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC Automation Tool |
Version: All versions < V4 SP2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.492Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "tags": [ "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC Automation Tool", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4 SP2" } ] }, { "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 14" } ] }, { "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Upd3" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC ProSave", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V17" } ] }, { "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V21.8" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2 Update 4" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 10" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC STEP 7 V5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.6 SP2 HF3" } ] }, { "product": "SIMATIC WinCC OA V3.16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.16 P018" } ] }, { "product": "SIMATIC WinCC OA V3.17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.17 P003" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC WinCC Runtime Professional V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Professional V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 10" } ] }, { "product": "SIMATIC WinCC Runtime Professional V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC WinCC Runtime Professional V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Update 14" } ] }, { "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.5 SP1 Update 3" } ] }, { "product": "SINAMICS STARTER", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.4 HF2" } ] }, { "product": "SINAMICS Startdrive", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V16 Update 3" } ] }, { "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0 SP2" } ] }, { "product": "SINEMA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP3" } ] }, { "product": "SINUMERIK ONE virtual", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V6.14" } ] }, { "product": "SINUMERIK Operate", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V6.14" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-428", "description": "CWE-428: Unquoted Search Path or Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-13T00:00:00", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7580", "datePublished": "2020-06-10T00:00:00", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.492Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-3449
Vulnerability from cvelistv5
Published
2021-03-25 14:25
Modified
2024-09-17 03:43
Severity ?
EPSS score ?
Summary
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T16:53:17.609Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.openssl.org/news/secadv/20210325.txt" }, { "tags": [ "x_transferred" ], "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148" }, { "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd" }, { "name": "DSA-4875", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.debian.org/security/2021/dsa-4875" }, { "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1" }, { "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2" }, { "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3" }, { "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4" }, { "name": "GLSA-202103-03", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://security.gentoo.org/glsa/202103-03" }, { "name": "FEDORA-2021-cbf14ab8f9", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/tns-2021-10" }, { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/tns-2021-09" }, { "tags": [ "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20210513-0002/" }, { "tags": [ "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20210326-0006/" }, { "tags": [ "x_transferred" ], "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc" }, { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/tns-2021-06" }, { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/tns-2021-05" }, { "tags": [ "x_transferred" ], "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf" }, { "tags": [ "x_transferred" ], "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845" }, { "tags": [ "x_transferred" ], "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013" }, { "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update", "tags": [ "mailing-list", "x_transferred" ], "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpujul2022.html" }, { "tags": [ "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20240621-0006/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "OpenSSL", "vendor": "OpenSSL", "versions": [ { "status": "affected", "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)" } ] } ], "credits": [ { "lang": "en", "value": "Peter K\u00e4stle (Nokia) and Samuel Sapalski (Nokia)" } ], "datePublic": "2021-03-25T00:00:00", "descriptions": [ { "lang": "en", "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)." } ], "metrics": [ { "other": { "content": { "lang": "eng", "url": "https://www.openssl.org/policies/secpolicy.html#High", "value": "High" }, "type": "unknown" } } ], "problemTypes": [ { "descriptions": [ { "description": "NULL pointer dereference", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-21T19:05:57.096577", "orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5", "shortName": "openssl" }, "references": [ { "url": "https://www.openssl.org/news/secadv/20210325.txt" }, { "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148" }, { "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021", "tags": [ "vendor-advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd" }, { "name": "DSA-4875", "tags": [ "vendor-advisory" ], "url": "https://www.debian.org/security/2021/dsa-4875" }, { "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1" }, { "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2" }, { "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3" }, { "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4" }, { "name": "GLSA-202103-03", "tags": [ "vendor-advisory" ], "url": "https://security.gentoo.org/glsa/202103-03" }, { "name": "FEDORA-2021-cbf14ab8f9", "tags": [ "vendor-advisory" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/" }, { "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "url": "https://www.tenable.com/security/tns-2021-10" }, { "url": "https://www.tenable.com/security/tns-2021-09" }, { "url": "https://security.netapp.com/advisory/ntap-20210513-0002/" }, { "url": "https://security.netapp.com/advisory/ntap-20210326-0006/" }, { "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc" }, { "url": "https://www.tenable.com/security/tns-2021-06" }, { "url": "https://www.tenable.com/security/tns-2021-05" }, { "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356" }, { "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf" }, { "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845" }, { "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013" }, { "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update", "tags": [ "mailing-list" ], "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html" }, { "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf" }, { "url": "https://www.oracle.com/security-alerts/cpujul2022.html" }, { "url": "https://security.netapp.com/advisory/ntap-20240621-0006/" } ], "title": "NULL pointer deref in signature_algorithms processing" } }, "cveMetadata": { "assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5", "assignerShortName": "openssl", "cveId": "CVE-2021-3449", "datePublished": "2021-03-25T14:25:13.659307Z", "dateReserved": "2021-03-17T00:00:00", "dateUpdated": "2024-09-17T03:43:55.497Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-27194
Vulnerability from cvelistv5
Published
2022-04-12 09:07
Modified
2024-08-03 05:25
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions < V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC PCS neo (Administration Console) |
Version: All versions < V3.1 SP1 |
||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:25:31.062Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC PCS neo (Administration Console)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1 SP1" } ] }, { "product": "SINETPLAN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "TIA Portal", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V15, V15.1, V16 and V17" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions \u003c V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-12T09:07:58", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-27194", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC PCS neo (Administration Console)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.1 SP1" } ] } }, { "product_name": "SINETPLAN", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "TIA Portal", "version": { "version_data": [ { "version_value": "V15, V15.1, V16 and V17" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions \u003c V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-27194", "datePublished": "2022-04-12T09:07:59", "dateReserved": "2022-03-15T00:00:00", "dateUpdated": "2024-08-03T05:25:31.062Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-46282
Vulnerability from cvelistv5
Published
2023-12-12 11:27
Modified
2025-01-14 10:29
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Foundation |
Version: 0 < V2407 |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:40.314Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "lessThan": "V2407", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "lessThan": "V2312", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-14T10:29:51.618Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46282", "datePublished": "2023-12-12T11:27:13.134Z", "dateReserved": "2023-10-20T10:29:46.260Z", "dateUpdated": "2025-01-14T10:29:51.618Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-46096
Vulnerability from cvelistv5
Published
2023-11-14 11:04
Modified
2025-01-08 16:38
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly authenticate users in the PUD Manager web service. This could allow an unauthenticated adjacent attacker to generate a privileged token and upload additional documents.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | SIMATIC PCS neo |
Version: All versions < V4.1 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:39.468Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-46096", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2023-12-09T05:05:26.060995Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-08T16:38:00.498Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS neo (All versions \u003c V4.1). The PUD Manager of affected products does not properly authenticate users in the PUD Manager web service. This could allow an unauthenticated adjacent attacker to generate a privileged token and upload additional documents." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-14T11:04:17.811Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46096", "datePublished": "2023-11-14T11:04:17.811Z", "dateReserved": "2023-10-16T11:24:12.685Z", "dateUpdated": "2025-01-08T16:38:00.498Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-46285
Vulnerability from cvelistv5
Published
2023-12-12 11:27
Modified
2025-01-14 10:29
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Foundation |
Version: 0 < V2407 |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:45:40.610Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "lessThan": "V2407", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "lessThan": "V2312", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20: Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-14T10:29:55.697Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46285", "datePublished": "2023-12-12T11:27:17.080Z", "dateReserved": "2023-10-20T10:29:46.260Z", "dateUpdated": "2025-01-14T10:29:55.697Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-7587
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Discrete |
Version: All versions < V3.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.877Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Opcenter Execution Discrete", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Process", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Intelligence", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V11.3" } ] }, { "product": "Opcenter RD\u0026L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V8.0" } ] }, { "product": "SIMATIC IT LMS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.6" } ] }, { "product": "SIMATIC IT Production Suite", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.0" } ] }, { "product": "SIMATIC Notifier Server for Windows", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMOCODE ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 4" } ] }, { "product": "SIMOCODE ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] }, { "product": "Soft Starter ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 3" } ] }, { "product": "Soft Starter ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:16:51", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-7587", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Opcenter Execution Discrete", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Foundation", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Process", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Intelligence", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "Opcenter Quality", "version": { "version_data": [ { "version_value": "All versions \u003c V11.3" } ] } }, { "product_name": "Opcenter RD\u0026L", "version": { "version_data": [ { "version_value": "V8.0" } ] } }, { "product_name": "SIMATIC IT LMS", "version": { "version_data": [ { "version_value": "All versions \u003c V2.6" } ] } }, { "product_name": "SIMATIC IT Production Suite", "version": { "version_data": [ { "version_value": "All versions \u003c V8.0" } ] } }, { "product_name": "SIMATIC Notifier Server for Windows", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS neo", "version": { "version_data": [ { "version_value": "All versions \u003c V3.0 SP1" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 5" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 2" } ] } }, { "product_name": "SIMOCODE ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 4" } ] } }, { "product_name": "SIMOCODE ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } }, { "product_name": "Soft Starter ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 3" } ] } }, { "product_name": "Soft Starter ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7587", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.877Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-41057
Vulnerability from cvelistv5
Published
2021-11-14 20:21
Modified
2024-08-04 02:59
Severity ?
EPSS score ?
Summary
In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions.
References
▼ | URL | Tags |
---|---|---|
https://www.wibu.com/us/support/security-advisories.html | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf | x_refsource_CONFIRM | |
https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T02:59:31.383Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.wibu.com/us/support/security-advisories.html" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-11-14T20:21:30", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.wibu.com/us/support/security-advisories.html" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-41057", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.wibu.com/us/support/security-advisories.html", "refsource": "MISC", "url": "https://www.wibu.com/us/support/security-advisories.html" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf" }, { "name": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf", "refsource": "CONFIRM", "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-41057", "datePublished": "2021-11-14T20:21:30", "dateReserved": "2021-09-13T00:00:00", "dateUpdated": "2024-08-04T02:59:31.383Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-46281
Vulnerability from cvelistv5
Published
2023-12-12 11:27
Modified
2025-01-14 10:29
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Foundation |
Version: 0 < V2407 |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:40.334Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-46281", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-08T14:41:24.487753Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-08T14:41:45.644Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "lessThan": "V2407", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "lessThan": "V2312", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-942", "description": "CWE-942: Permissive Cross-domain Policy with Untrusted Domains", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-14T10:29:50.318Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46281", "datePublished": "2023-12-12T11:27:11.796Z", "dateReserved": "2023-10-20T10:29:46.259Z", "dateUpdated": "2025-01-14T10:29:50.318Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-20093
Vulnerability from cvelistv5
Published
2021-06-16 11:09
Modified
2024-08-03 17:30
Severity ?
EPSS score ?
Summary
A buffer over-read vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server.
References
▼ | URL | Tags |
---|---|---|
https://www.tenable.com/security/research/tra-2021-24 | x_refsource_MISC | |
https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-01.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf | x_refsource_CONFIRM | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Wibu-Systems CodeMeter |
Version: < 7.21a |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:30:07.515Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2021-24" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-01.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Wibu-Systems CodeMeter", "vendor": "n/a", "versions": [ { "status": "affected", "version": "\u003c 7.21a" } ] } ], "descriptions": [ { "lang": "en", "value": "A buffer over-read vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server." } ], "problemTypes": [ { "descriptions": [ { "description": "Buffer Over-read", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-05T20:11:49", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2021-24" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-01.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnreport@tenable.com", "ID": "CVE-2021-20093", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Wibu-Systems CodeMeter", "version": { "version_data": [ { "version_value": "\u003c 7.21a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A buffer over-read vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Buffer Over-read" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2021-24", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2021-24" }, { "name": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-01.pdf", "refsource": "MISC", "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-01.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2021-20093", "datePublished": "2021-06-16T11:09:02", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:30:07.515Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-46099
Vulnerability from cvelistv5
Published
2023-11-14 11:04
Modified
2025-01-08 16:21
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). There is a stored cross-site scripting vulnerability in the Administration Console of the affected product, that could allow an attacker with high privileges to inject Javascript code into the application that is later executed by another legitimate user.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | SIMATIC PCS neo |
Version: All versions < V4.1 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:39.392Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-46099", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2023-12-09T05:05:27.027267Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-08T16:21:04.932Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS neo (All versions \u003c V4.1). There is a stored cross-site scripting vulnerability in the Administration Console of the affected product, that could allow an attacker with high privileges to inject Javascript code into the application that is later executed by another legitimate user." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-14T11:04:21.326Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46099", "datePublished": "2023-11-14T11:04:21.326Z", "dateReserved": "2023-10-16T11:24:12.686Z", "dateUpdated": "2025-01-08T16:21:04.932Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-7588
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Discrete |
Version: All versions < V3.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.850Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Opcenter Execution Discrete", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Process", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Intelligence", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V11.3" } ] }, { "product": "Opcenter RD\u0026L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V8.0" } ] }, { "product": "SIMATIC IT LMS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.6" } ] }, { "product": "SIMATIC IT Production Suite", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.0" } ] }, { "product": "SIMATIC Notifier Server for Windows", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMOCODE ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 4" } ] }, { "product": "SIMOCODE ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] }, { "product": "Soft Starter ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 3" } ] }, { "product": "Soft Starter ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20: Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:16:56", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-7588", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Opcenter Execution Discrete", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Foundation", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Process", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Intelligence", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "Opcenter Quality", "version": { "version_data": [ { "version_value": "All versions \u003c V11.3" } ] } }, { "product_name": "Opcenter RD\u0026L", "version": { "version_data": [ { "version_value": "V8.0" } ] } }, { "product_name": "SIMATIC IT LMS", "version": { "version_data": [ { "version_value": "All versions \u003c V2.6" } ] } }, { "product_name": "SIMATIC IT Production Suite", "version": { "version_data": [ { "version_value": "All versions \u003c V8.0" } ] } }, { "product_name": "SIMATIC Notifier Server for Windows", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS neo", "version": { "version_data": [ { "version_value": "All versions \u003c V3.0 SP1" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 5" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 2" } ] } }, { "product_name": "SIMOCODE ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 4" } ] } }, { "product_name": "SIMOCODE ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } }, { "product_name": "Soft Starter ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 3" } ] } }, { "product_name": "Soft Starter ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20: Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7588", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.850Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-46098
Vulnerability from cvelistv5
Published
2023-11-14 11:04
Modified
2025-01-08 16:35
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). When accessing the Information Server from affected products, the products use an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | SIMATIC PCS neo |
Version: All versions < V4.1 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:39.455Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-46098", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2023-12-09T05:05:24.120438Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-08T16:35:08.154Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS neo (All versions \u003c V4.1). When accessing the Information Server from affected products, the products use an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-942", "description": "CWE-942: Permissive Cross-domain Policy with Untrusted Domains", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-14T11:04:20.174Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46098", "datePublished": "2023-11-14T11:04:20.174Z", "dateReserved": "2023-10-16T11:24:12.686Z", "dateUpdated": "2025-01-08T16:35:08.154Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-7581
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Discrete |
Version: All versions < V3.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.617Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Opcenter Execution Discrete", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Process", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Intelligence", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V11.3" } ] }, { "product": "Opcenter RD\u0026L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V8.0" } ] }, { "product": "SIMATIC Notifier Server for Windows", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMOCODE ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 4" } ] }, { "product": "SIMOCODE ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] }, { "product": "Soft Starter ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 3" } ] }, { "product": "Soft Starter ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-428", "description": "CWE-428: Unquoted Search Path or Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:16:47", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-7581", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Opcenter Execution Discrete", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Foundation", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Process", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Intelligence", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "Opcenter Quality", "version": { "version_data": [ { "version_value": "All versions \u003c V11.3" } ] } }, { "product_name": "Opcenter RD\u0026L", "version": { "version_data": [ { "version_value": "V8.0" } ] } }, { "product_name": "SIMATIC Notifier Server for Windows", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS neo", "version": { "version_data": [ { "version_value": "All versions \u003c V3.0 SP1" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 5" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 2" } ] } }, { "product_name": "SIMOCODE ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 4" } ] } }, { "product_name": "SIMOCODE ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } }, { "product_name": "Soft Starter ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 3" } ] } }, { "product_name": "Soft Starter ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-428: Unquoted Search Path or Element" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7581", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.617Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-46283
Vulnerability from cvelistv5
Published
2023-12-12 11:27
Modified
2025-01-14 10:29
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Foundation |
Version: 0 < V2407 |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:45:40.675Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "lessThan": "V2407", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "lessThan": "V2312", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-14T10:29:52.922Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46283", "datePublished": "2023-12-12T11:27:14.437Z", "dateReserved": "2023-10-20T10:29:46.260Z", "dateUpdated": "2025-01-14T10:29:52.922Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-38558
Vulnerability from cvelistv5
Published
2023-09-14 10:39
Modified
2024-08-02 17:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC PCS neo (Administration Console) V4.0 (All versions), SIMATIC PCS neo (Administration Console) V4.0 Update 1 (All versions). The affected application leaks Windows admin credentials. An attacker with local access to the Administration Console could get the credentials, and impersonate the admin user, thereby gaining admin access to other Windows systems.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC PCS neo (Administration Console) V4.0 |
Version: All versions |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:46:56.344Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646240.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC PCS neo (Administration Console) V4.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS neo (Administration Console) V4.0 Update 1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS neo (Administration Console) V4.0 (All versions), SIMATIC PCS neo (Administration Console) V4.0 Update 1 (All versions). The affected application leaks Windows admin credentials. An attacker with local access to the Administration Console could get the credentials, and impersonate the admin user, thereby gaining admin access to other Windows systems." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-538", "description": "CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-09-14T10:39:29.769Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646240.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-38558", "datePublished": "2023-09-14T10:39:29.769Z", "dateReserved": "2023-07-20T08:17:26.143Z", "dateUpdated": "2024-08-02T17:46:56.344Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2023-11-14 11:15
Modified
2024-11-21 08:27
Severity ?
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). When accessing the Information Server from affected products, the products use an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_pcs_neo | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS neo (All versions \u003c V4.1). When accessing the Information Server from affected products, the products use an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS neo (todas las versiones \u0026lt; V4.1). Al acceder al servidor de informaci\u00f3n desde los productos afectados, los productos utilizan una pol\u00edtica CORS demasiado permisiva. Esto podr\u00eda permitir a un atacante enga\u00f1ar a un usuario leg\u00edtimo para provocar un comportamiento no deseado." } ], "id": "CVE-2023-46098", "lastModified": "2024-11-21T08:27:53.723", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.0, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.1, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-11-14T11:15:14.553", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-942" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 05:37
Severity ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:*", "matchCriteriaId": "F33BF89C-F36E-4C8F-ABB9-579E2022DDA6", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DCE5E06-B75F-4D21-96CC-70DD373B1811", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4DD5C57-5877-495C-A01E-747E5DCED9F7", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA9BAFAE-C26A-4435-80C1-508F0A3EF768", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*", "matchCriteriaId": "9DB2F53B-817C-41F3-9B52-85DE702ACCE5", "versionEndExcluding": "11.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_rd\\\u0026l:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "EE037602-C9E8-45D5-9A44-3B73052F478E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_lms:*:*:*:*:*:*:*:*", "matchCriteriaId": "524AE90C-821A-4864-B3B2-33C083B536CB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_production_suite:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6324685-60ED-44CC-BAEA-3BEEBE681AC5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*", "matchCriteriaId": "DE74021F-CE57-42CC-8093-E1B0352410FA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "D61D4B81-7F51-49BE-83DD-D2C28D23B0EA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "2190AEE1-7EEA-48A9-B6C7-FF4B3A26008E", "versionEndIncluding": "15.1", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*", "matchCriteriaId": "66CB66B9-176E-4FA3-BC67-E7C5972A307C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:update_1:*:*:*:*:*:*", "matchCriteriaId": "4E011D6F-CC5F-4278-80AB-D568730AA041", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE934FDC-666F-4D9D-9C03-2896875F0A0D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA57190F-97BA-4D1D-BC73-F37162B775F9", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Opcenter Execution Discrete (Todas las versiones anteriores a V3.2), Opcenter Execution Foundation (Todas las versiones anteriores a V3.2), Opcenter Execution Process (Todas las versiones anteriores a V3.2), Opcenter Intelligence (Todas las versiones anteriores a V3.3), Opcenter Quality (Todas las versiones anteriores a V11.3), Opcenter RD\u0026amp;L (V8.0), SIMATIC IT LMS (Todas las versiones anteriores a V2.6), SIMATIC IT Production Suite (Todas las versiones anteriores a V8. 0), SIMATIC Notifier Server for Windows (Todas las versiones), SIMATIC PCS neo (Todas las versiones anteriores a V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a V16 Update 2), SIMOCODE ES V15. 1 (Todas las versiones anteriores a V15.1 Update 4), SIMOCODE ES V16 (Todas las versiones anteriores a V16 Update 1), Soft Starter ES V15.1 (Todas las versiones anteriores a V15.1 Update 3), Soft Starter ES V16 (Todas las versiones anteriores a V16 Update 1). El env\u00edo de un paquete especialmente dise\u00f1ado al servicio afectado podr\u00eda causar una denegaci\u00f3n de servicio remota parcial, que har\u00eda que el servicio se reiniciara" } ], "id": "CVE-2020-7588", "lastModified": "2024-11-21T05:37:25.660", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:18.993", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2021-03-25 15:15
Modified
2024-11-21 06:21
Severity ?
Summary
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*", "matchCriteriaId": "B213E696-A6D9-45E7-B4E4-E4CFE54ECEB8", "versionEndExcluding": "1.1.1k", "versionStartIncluding": "1.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*", "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252", "vulnerable": true }, { "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*", "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:-:*:*:*:*:*:*", "matchCriteriaId": "73D9C08B-8F5B-40C4-A5BD-B00D2E4C012D", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p1:*:*:*:*:*:*", "matchCriteriaId": "62A178A3-6A52-4981-9A27-FB07AD8AF778", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p2:*:*:*:*:*:*", "matchCriteriaId": "54A487B1-E5CE-4C76-87E8-518D24C5D86D", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*", "matchCriteriaId": "3A756737-1CC4-42C2-A4DF-E1C893B4E2D5", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*", "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:e-series_performance_analyzer:-:*:*:*:*:*:*:*", "matchCriteriaId": "24B8DB06-590A-4008-B0AB-FCD1401C77C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:oncommand_insight:-:*:*:*:*:*:*:*", "matchCriteriaId": "F1BE6C1F-2565-4E97-92AA-16563E5660A5", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:oncommand_workflow_automation:-:*:*:*:*:*:*:*", "matchCriteriaId": "5735E553-9731-4AAC-BCFF-989377F817B3", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:ontap_select_deploy_administration_utility:-:*:*:*:*:*:*:*", "matchCriteriaId": "E7CF3019-975D-40BB-A8A4-894E62BD3797", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:santricity_smi-s_provider:-:*:*:*:*:*:*:*", "matchCriteriaId": "361B791A-D336-4431-8F68-8135BEFFAEA2", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:snapcenter:-:*:*:*:*:*:*:*", "matchCriteriaId": "BDFB1169-41A0-4A86-8E4F-FDA9730B1E94", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:storagegrid:-:*:*:*:*:*:*:*", "matchCriteriaId": "8ADFF451-740F-4DBA-BD23-3881945D3E40", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:tenable:log_correlation_engine:*:*:*:*:*:*:*:*", "matchCriteriaId": "4ACF85D6-6B45-43DA-9C01-F0208186F014", "versionEndExcluding": "6.0.9", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus:*:*:*:*:*:*:*:*", "matchCriteriaId": "0AC12300-9051-4C70-9941-9FE5E64B4B30", "versionEndIncluding": "8.13.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.0:*:*:*:*:*:*:*", "matchCriteriaId": "657682A0-54D5-4DC6-A98E-8BAF685926C4", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.1:*:*:*:*:*:*:*", "matchCriteriaId": "8FC5C76C-3474-4B26-8CF0-2DFAFA3D5458", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.0:*:*:*:*:*:*:*", "matchCriteriaId": "8661D361-71B5-4C41-A818-C89EC551D900", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.1:*:*:*:*:*:*:*", "matchCriteriaId": "253603DC-2D92-442A-B3A8-A63E14D8A070", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.13.0:*:*:*:*:*:*:*", "matchCriteriaId": "8E112CFF-31F9-4D87-9A1B-AE0FCF69615E", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:tenable.sc:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC1721B5-9FCD-47C3-8338-E02932CF2C05", "versionEndIncluding": "5.17.0", "versionStartIncluding": "5.13.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:fedoraproject:fedora:34:*:*:*:*:*:*:*", "matchCriteriaId": "A930E247-0B43-43CB-98FF-6CE7B8189835", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mcafee:web_gateway:8.2.19:*:*:*:*:*:*:*", "matchCriteriaId": "DEA7F1FD-9FAB-4654-98B0-4588EEC8B69A", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway:9.2.10:*:*:*:*:*:*:*", "matchCriteriaId": "868B2C4B-CE6B-41DA-A373-7D4FA51EFE9F", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway:10.1.1:*:*:*:*:*:*:*", "matchCriteriaId": "550F47A2-3393-481E-BC40-CE606BFA8776", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:8.2.19:*:*:*:*:*:*:*", "matchCriteriaId": "43392D27-6C07-41C7-A17F-10C433338CE9", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:9.2.10:*:*:*:*:*:*:*", "matchCriteriaId": "8FBF6C4C-195F-49A7-861D-52677D9BE58D", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:10.1.1:*:*:*:*:*:*:*", "matchCriteriaId": "90732D53-E802-4E1B-B6C8-B1FDCE7905A4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r80.40:*:*:*:*:*:*:*", "matchCriteriaId": "A98B128A-C58E-48EC-B691-AF73126A0822", "vulnerable": true }, { "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r81:*:*:*:*:*:*:*", "matchCriteriaId": "345B990F-C1C4-440B-804E-0A2882FE7C01", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:checkpoint:quantum_security_management:-:*:*:*:*:*:*:*", "matchCriteriaId": "08601413-25E2-4977-B67A-C11A9D788EA8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r80.40:*:*:*:*:*:*:*", "matchCriteriaId": "EFC067CC-EB90-43F5-9674-089D5C611573", "vulnerable": true }, { "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r81:*:*:*:*:*:*:*", "matchCriteriaId": "80B223A7-1039-445D-ABE1-5E481004D956", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:checkpoint:multi-domain_management:-:*:*:*:*:*:*:*", "matchCriteriaId": "1584E1B4-412C-40E2-BF07-4E464692F2AE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r80.40:*:*:*:*:*:*:*", "matchCriteriaId": "A0002A29-8B42-445D-9EC4-58BC93194241", "vulnerable": true }, { "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r81:*:*:*:*:*:*:*", "matchCriteriaId": "3B0EDB21-9305-4601-AB96-A77BD00F311D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:checkpoint:quantum_security_gateway:-:*:*:*:*:*:*:*", "matchCriteriaId": "9016DDF6-285C-4E64-88D0-29ECCEF048F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:oracle:communications_communications_policy_management:12.6.0.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "570DB369-A31B-4108-A7FD-09F674129603", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:enterprise_manager_for_storage_management:13.4.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "61516569-C48F-4362-B334-8CA10EDB0EC2", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:essbase:21.2:*:*:*:*:*:*:*", "matchCriteriaId": "394A16F2-CCD4-44E5-BF6B-E0C782A9FA38", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:graalvm:19.3.5:*:*:*:enterprise:*:*:*", "matchCriteriaId": "058C7C4B-D692-49DE-924A-C2725A8162D3", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:graalvm:20.3.1.2:*:*:*:enterprise:*:*:*", "matchCriteriaId": "0F0434A5-F2A1-4973-917C-A95F2ABE97D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:graalvm:21.0.0.2:*:*:*:enterprise:*:*:*", "matchCriteriaId": "96DD93E0-274E-4C36-99F3-EEF085E57655", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:jd_edwards_enterpriseone_tools:*:*:*:*:*:*:*:*", "matchCriteriaId": "86305E47-33E9-411C-B932-08C395C09982", "versionEndExcluding": "9.2.6.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:jd_edwards_world_security:a9.4:*:*:*:*:*:*:*", "matchCriteriaId": "0B1CAD50-749F-4ADB-A046-BF3585677A58", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:mysql_connectors:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8782A14-89B0-45EE-A5CB-FF715F5BA379", "versionEndIncluding": "8.0.23", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C40ECC8-933B-47A4-8082-FCF0EF9C973E", "versionEndIncluding": "5.7.33", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "32714AD7-BCD1-4624-9923-5E6D927CF3CB", "versionEndIncluding": "8.0.23", "versionStartIncluding": "8.0.15", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:mysql_workbench:*:*:*:*:*:*:*:*", "matchCriteriaId": "CB1A94E1-A6C6-488D-A74C-6C0B24637272", "versionEndIncluding": "8.0.23", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.57:*:*:*:*:*:*:*", "matchCriteriaId": "7E1E416B-920B-49A0-9523-382898C2979D", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.58:*:*:*:*:*:*:*", "matchCriteriaId": "D9DB4A14-2EF5-4B54-95D2-75E6CF9AA0A9", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.59:*:*:*:*:*:*:*", "matchCriteriaId": "C8AF00C6-B97F-414D-A8DF-057E6BFD8597", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:primavera_unifier:*:*:*:*:*:*:*:*", "matchCriteriaId": "08FA59A8-6A62-4B33-8952-D6E658F8DAC9", "versionEndIncluding": "17.12", "versionStartIncluding": "17.7", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:primavera_unifier:19.12:*:*:*:*:*:*:*", "matchCriteriaId": "10864586-270E-4ACF-BDCC-ECFCD299305F", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:primavera_unifier:20.12:*:*:*:*:*:*:*", "matchCriteriaId": "38340E3C-C452-4370-86D4-355B6B4E0A06", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:primavera_unifier:21.12:*:*:*:*:*:*:*", "matchCriteriaId": "E9C55C69-E22E-4B80-9371-5CD821D79FE2", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:secure_backup:*:*:*:*:*:*:*:*", "matchCriteriaId": "C01E8B82-71C7-4A4A-A70A-7B147524AB4A", "versionEndExcluding": "18.1.0.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:secure_global_desktop:5.6:*:*:*:*:*:*:*", "matchCriteriaId": "9DA11710-9EA8-49B4-8FD1-3AEE442F6ADC", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:zfs_storage_appliance_kit:8.8:*:*:*:*:*:*:*", "matchCriteriaId": "D3E503FB-6279-4D4A-91D8-E237ECF9D2B0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:sonicwall:sma100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6E8B6D50-D482-43E9-A20D-FA77FD59AE2D", "versionEndExcluding": "10.2.1.0-17sv", "versionStartIncluding": "10.2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:sonicwall:sma100:-:*:*:*:*:*:*:*", "matchCriteriaId": "8E4A2B7B-40F5-4AE0-ACC7-E94B82435DBA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:sonicwall:capture_client:3.5:*:*:*:*:*:*:*", "matchCriteriaId": "349EB4AE-65E3-42DC-8F9C-3A1A155324D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:sonicwall:sonicos:7.0.1.0:*:*:*:*:*:*:*", "matchCriteriaId": "2BD8688A-2D55-4A7E-A143-1BD0FCF957B0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ruggedcom_rcm1224_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5081E52B-E7C0-46BD-B1D0-2C70ABCC8831", "versionStartIncluding": "6.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ruggedcom_rcm1224:-:*:*:*:*:*:*:*", "matchCriteriaId": "3747CDD7-E833-4B68-A362-77D6A2E9D888", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_lpe9403_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "058D21EA-E94C-4DDC-AD92-967DAC934457", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_lpe9403:-:*:*:*:*:*:*:*", "matchCriteriaId": "52A77C9D-E59C-4397-B834-797D7B334A6B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "424CD8EA-D8CB-40C7-8E0F-AC4B05C59C99", "versionStartIncluding": "6.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s602_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "858B6A84-5D0E-4E23-AE32-A45B51BAC8CF", "versionStartIncluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s602:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4D89D82-C2CE-44DC-A05B-B956F20BF4E3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s612_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D173626B-9C50-489F-8BA4-1C45E5F96526", "versionStartIncluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s612:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA7B48D2-0D17-420D-AAE1-35E5C0BE2924", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E967F5FC-6F3E-4982-8813-CA1DAF3BE165", "versionStartIncluding": "6.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*", "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s623_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81F315D8-0B26-4442-B330-85124017A482", "versionStartIncluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s623:-:*:*:*:*:*:*:*", "matchCriteriaId": "F80D9A79-7984-462B-B4B9-6A4429422038", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s627-2m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F20F735-7A70-4A24-9621-786F99C8F87D", "versionStartIncluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s627-2m:-:*:*:*:*:*:*:*", "matchCriteriaId": "B51B40F8-71D2-4D2D-8EC2-CE154A6D7533", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_sc-600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "973B8030-B630-4D67-B897-25A359A96185", "versionStartIncluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_sc-600:-:*:*:*:*:*:*:*", "matchCriteriaId": "725C671B-D7A0-48CF-8A31-5F9C4173F1DD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86EA8E3F-81BD-47BC-9834-A9B69CA7E70C", "versionStartIncluding": "6.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_w1700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BE116AD9-B55F-41C8-8B55-329809DB63E1", "versionStartIncluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_w1700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5D9A73DD-4A21-4096-B4B6-A0A825E71006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "144CDF5E-7E07-428B-B4DF-C94992B3A44A", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "339FFBDF-6957-481F-84CE-878B5CAAD9C8", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FBB13D3-4E04-4D01-B880-C16C4FFA240B", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*", "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E40058B3-3726-4F6A-AB41-7679487639F2", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xm-400:-:*:*:*:*:*:*:*", "matchCriteriaId": "798E900F-5EF9-4B39-B8C2-79FAE659E7F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E642D10-E701-44DF-863B-D0DAA5530F50", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A53C2B5-A3FD-44CC-A78B-D2124EF37DB4", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*", "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54FBE4D4-F31E-4B61-9216-44C8EC2988AB", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*", "matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "20511D61-FC1D-453E-BDF6-D3FB9951192A", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*", "matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "640AC619-B516-46FC-821B-09C4542A3FD6", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1FB979DB-731B-4693-A9F8-B11ED953717C", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*", "matchCriteriaId": "09743616-31C9-4E47-8A4A-B15D76204BE7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "886D2FE6-B054-4E3B-BACB-F08C0A119A80", "versionStartIncluding": "1.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "3B185B70-CAC9-47AC-8639-7A4707C21540", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cloud_connect_7:-:*:*:*:*:*:*:*", "matchCriteriaId": "9FA78457-260C-467B-9785-04B3C8EDF3B3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ABEA3BEE-E7AF-4C9A-ADE4-CE7FC1DB7639", "versionStartIncluding": "3.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "049460B8-6186-44F9-B41F-284A2EC0B3B4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "205482DA-548C-4757-91F0-1599438873BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_basic_panels_2nd_generation_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45208694-635A-42AC-B668-8B67C60568B8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_basic_panels_2nd_generation:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D8F8BCE-35CE-492A-8BFE-2C36EA51CE5C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4C147D9-4649-4289-B18B-55BD6E33521A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54EFA8B5-8DA1-4547-9E15-BDC265C56006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_mv500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DE4FA1E6-4C5A-4CDC-AD40-E384C0BCA90D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_mv500:-:*:*:*:*:*:*:*", "matchCriteriaId": "93A5B50E-0316-4189-8F41-54732CFCF63F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D254DA1D-C53E-426B-9C69-580CC47CF0AA", "versionStartIncluding": "3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "65278BA0-3C81-4D81-9801-D7BE3A1D7680", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C06A02ED-0BA3-4A2C-AF0C-689B8AEB34B8", "versionStartIncluding": "3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_eu:-:*:*:*:*:*:*:*", "matchCriteriaId": "209C7B1E-10F6-4215-AF69-CC36192E0FCE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_us_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CF8C00EE-1154-440C-A223-A2CE99CE3126", "versionStartIncluding": "3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_us:-:*:*:*:*:*:*:*", "matchCriteriaId": "171A9543-E677-422F-8AEA-1BC2D0E53593", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB201DD3-8890-453E-A11E-1E13B3DAB3F9", "versionStartIncluding": "3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-8_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "350FD323-C876-4C7A-A2E7-4B0660C87F6C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61E498B1-87FF-454B-8DF0-61D0D3208491", "versionStartIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1542sp-1_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1EE2F10-A7A6-486F-AE5C-53AE25BAF200", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90FB801F-11B5-438C-98A1-E928BFEA2ADB", "versionEndExcluding": "3.0", "versionStartIncluding": "2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "F56C2BDC-928E-491A-8E7C-F976B3787C7A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4BA1E6-64F7-4B96-8302-134057DAB1BE", "versionStartIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543sp-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "783B50B8-2FB7-4982-88AA-B4F2AD094796", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1545-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DCA9544-DD17-4F56-B34C-91A3F37154AF", "versionStartIncluding": "1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1545-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "1256EB4B-DD8A-4F99-AE69-F74E8F789C63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_pcs_7_telecontrol_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C25165E-EDE9-42F1-A3B9-0E47630D49CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_pcs_7_telecontrol:-:*:*:*:*:*:*:*", "matchCriteriaId": "5BF281FB-26E0-43E4-A2B6-4015661368AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_pcs_neo_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6EEACFC9-41B7-4EE0-9427-692363880326", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_pcs_neo:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3CA343-CA2A-4593-930C-158612CE7A55", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_pdm_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E9AE23E-7DAE-4191-BA4E-A7CD655C4BC8", "versionStartIncluding": "9.1.0.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_pdm:-:*:*:*:*:*:*:*", "matchCriteriaId": "E092B735-42D5-48D5-947B-288C0FA2E180", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D874D636-392A-4750-B976-F411DBCEBA8D", "versionStartIncluding": "2019", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_process_historian_opc_ua_server:-:*:*:*:*:*:*:*", "matchCriteriaId": "14EC9343-7778-40B0-A74D-5C156FF2A229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf166c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "968FBB4E-5B0B-43D4-B3AD-418028093990", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf166c:-:*:*:*:*:*:*:*", "matchCriteriaId": "391AD485-A49D-43D0-AAE5-1F58B38D4E22", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5212F097-B65A-4D73-BB6F-49687F8AD980", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*", "matchCriteriaId": "82494B5E-80EE-47ED-B87E-CF8C8907B6FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D806113B-57EB-4AA0-9D5E-12E30337A93B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*", "matchCriteriaId": "9B0933EB-82BE-42BB-978B-C9EC2FE1C795", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf186ci_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "53FA50A7-2DF6-454E-8A8E-838C392AB417", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf186ci:-:*:*:*:*:*:*:*", "matchCriteriaId": "1EAEB335-BD22-4CEF-A3EA-9D98A09FEBF0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F3D41E9-58B3-4251-8710-A8C4A24ABBD3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*", "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf188ci_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FC628CB7-0816-4267-9C5D-954BD0233D2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf188ci:-:*:*:*:*:*:*:*", "matchCriteriaId": "B0927991-E820-4FC3-9EFE-96E4C9BFCCCD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf360r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "88E64167-16AA-48D7-BCDC-B15D37FA666D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf360r:-:*:*:*:*:*:*:*", "matchCriteriaId": "63F05227-208B-42C8-8D56-A5D106CAD32F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47F1294A-1C26-4D43-9C53-D833F2510536", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*", "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4AF60081-D534-44F5-972F-23257F16F372", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*", "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AEF1726E-B56F-4D39-AFF4-E79A3CA00DE6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4948734A-0AAD-4D28-B7FF-FFBBB9AA39C6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*", "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6EE37798-B068-40E5-BC03-1D8D303E5926", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E0C491C-5C4A-4F1C-ABD4-9502A54AAA78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E7657063-1296-4734-B108-A2FF7A01B07F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*", "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8C477CCD-06C7-4907-8B0C-4FCE7F6DADAD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_connect_300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3360ACCE-E735-4E34-B278-0D4460E74CBF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_connect_300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7B854F5B-78C7-41FE-9364-5E71B36342A3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D2B20D95-C4B3-4D13-A3D8-F22AC42DC059", "versionEndExcluding": "2.2", "versionStartIncluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_logon:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6F24E40-F3F0-48F3-B3DC-5F98B0564F7A", "versionStartIncluding": "1.6.0.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_logon:1.5:sp3_update_1:*:*:*:*:*:*", "matchCriteriaId": "423359E5-9C36-4C6B-AB24-B030E6C61D53", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_telecontrol:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3169FD3-CBA2-417C-95EF-4F8AE9FAB5AD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:-:*:*:*:*:*:*", "matchCriteriaId": "4ED13FC8-63C0-42C6-A51C-C480C45327C2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "E68FE047-8F53-46B8-82D4-9342B1C8CA55", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_pni:-:*:*:*:*:*:*:*", "matchCriteriaId": "1353DC31-FB12-427A-B1B2-9164A4BEE14B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:-:*:*:*:*:*:*", "matchCriteriaId": "B0A5CC25-A323-4D49-8989-5A417D12D646", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "A690BCD3-6497-43F7-8A51-E033B9121DC8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2:*:*:*:*:*:*", "matchCriteriaId": "AA375D44-ECC5-4BD3-A3D5-6D2AA68782D5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update1:*:*:*:*:*:*", "matchCriteriaId": "6CD26C73-B61F-424B-91C2-352E2CAE6666", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update2:*:*:*:*:*:*", "matchCriteriaId": "DB4EA15F-ECA4-477F-948F-490FC90BC66A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "ABA14E65-214C-431D-A49A-D8FC142D4541", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*", "matchCriteriaId": "915B09CB-CA0A-445B-89D3-16AE9B08858E", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:sinec_infrastructure_network_services:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0F46497-4AB0-49A7-9453-CC26837BF253", "versionEndExcluding": "1.0.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*", "matchCriteriaId": "25A3180B-21AF-4010-9DAB-41ADFD2D8031", "versionEndIncluding": "10.12.0", "versionStartIncluding": "10.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*", "matchCriteriaId": "43B199B4-D89C-483D-ACAE-6CB2A59EE67C", "versionEndIncluding": "10.24.0", "versionStartIncluding": "10.13.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*", "matchCriteriaId": "564ED5C8-50D7-413A-B88E-E62B6C07336A", "versionEndIncluding": "12.12.0", "versionStartIncluding": "12.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*", "matchCriteriaId": "3DEBF7C8-B000-47B9-B597-DC440F2603B3", "versionEndExcluding": "12.22.1", "versionStartIncluding": "12.13.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*", "matchCriteriaId": "428DCD7B-6F66-4F18-B780-5BD80143D482", "versionEndIncluding": "14.14.0", "versionStartIncluding": "14.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*", "matchCriteriaId": "380D03F3-6A7E-43A2-B002-FB2521FD3C58", "versionEndExcluding": "14.16.1", "versionStartIncluding": "14.15.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*", "matchCriteriaId": "3ED4D313-F372-4CC1-BE11-6BBA2F0E90E3", "versionEndExcluding": "15.14.0", "versionStartIncluding": "15.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)." }, { "lang": "es", "value": "Un servidor OpenSSL TLS puede cometer un fallo si un cliente env\u00eda un mensaje ClientHello de renegociaci\u00f3n dise\u00f1ado maliciosamente.\u0026#xa0;Si una renegociaci\u00f3n de TLSv1.2 ClientHello omite la extensi\u00f3n signature_algorithms (donde estaba presente en el ClientHello inicial), pero incluye una extensi\u00f3n signature_algorithms_cert, se producir\u00e1 una desreferencia del puntero NULL, lo que conllevar\u00e1 un bloqueo y un ataque de denegaci\u00f3n de servicio.\u0026#xa0;Un servidor solo es vulnerable si tiene TLSv1.2 y la renegociaci\u00f3n habilitada (que es la configuraci\u00f3n predeterminada).\u0026#xa0;Los clientes de OpenSSL TLS no est\u00e1n afectados por este problema.\u0026#xa0;Todas las versiones de OpenSSL versi\u00f3n 1.1.1 est\u00e1n afectadas por este problema.\u0026#xa0;Los usuarios de estas versiones deben actualizar a OpenSSL versi\u00f3n 1.1.1k.\u0026#xa0;OpenSSL versi\u00f3n 1.0.2 no est\u00e1 afectado por este problema.\u0026#xa0;Corregido en OpenSSL versi\u00f3n 1.1.1k (Afectadas versiones 1.1.1-1.1.1j)" } ], "id": "CVE-2021-3449", "lastModified": "2024-11-21T06:21:33.050", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-25T15:15:13.450", "references": [ { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1" }, { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2" }, { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3" }, { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf" }, { "source": "openssl-security@openssl.org", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf" }, { "source": "openssl-security@openssl.org", "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356" }, { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html" }, { "source": "openssl-security@openssl.org", "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://security.gentoo.org/glsa/202103-03" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20210326-0006/" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20210513-0002/" }, { "source": "openssl-security@openssl.org", "url": "https://security.netapp.com/advisory/ntap-20240621-0006/" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.debian.org/security/2021/dsa-4875" }, { "source": "openssl-security@openssl.org", "tags": [ "Vendor Advisory" ], "url": "https://www.openssl.org/news/secadv/20210325.txt" }, { "source": "openssl-security@openssl.org", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpujul2022.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-05" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-06" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-09" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-10" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.gentoo.org/glsa/202103-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20210326-0006/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20210513-0002/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://security.netapp.com/advisory/ntap-20240621-0006/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.debian.org/security/2021/dsa-4875" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.openssl.org/news/secadv/20210325.txt" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpujul2022.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-05" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-06" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-09" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-10" } ], "sourceIdentifier": "openssl-security@openssl.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-476" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 05:37
Severity ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:*", "matchCriteriaId": "F33BF89C-F36E-4C8F-ABB9-579E2022DDA6", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DCE5E06-B75F-4D21-96CC-70DD373B1811", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4DD5C57-5877-495C-A01E-747E5DCED9F7", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA9BAFAE-C26A-4435-80C1-508F0A3EF768", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*", "matchCriteriaId": "9DB2F53B-817C-41F3-9B52-85DE702ACCE5", "versionEndExcluding": "11.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_rd\\\u0026l:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "EE037602-C9E8-45D5-9A44-3B73052F478E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*", "matchCriteriaId": "DE74021F-CE57-42CC-8093-E1B0352410FA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "D61D4B81-7F51-49BE-83DD-D2C28D23B0EA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6D968D9-2A64-4E1C-824F-6508AEC6789D", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*", "matchCriteriaId": "66CB66B9-176E-4FA3-BC67-E7C5972A307C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*", "matchCriteriaId": "EF2D6947-576B-4CA7-B4E4-F0B428FA5ABB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE934FDC-666F-4D9D-9C03-2896875F0A0D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA57190F-97BA-4D1D-BC73-F37162B775F9", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Opcenter Execution Discrete (Todas las versiones anteriores a V3.2), Opcenter Execution Foundation (Todas las versiones anteriores a V3.2), Opcenter Execution Process (Todas las versiones anteriores a V3.2), Opcenter Intelligence (Todas las versiones anteriores a V3.3), Opcenter Quality (Todas las versiones anteriores a V11.3), Opcenter RD\u0026amp;L (V8.0), SIMATIC Notifier Server for Windows (Todas las versiones), SIMATIC PCS neo (Todas las versiones anteriores a V3. 0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a V16 Update 2), SIMOCODE ES V15.1 (Todas las versiones anteriores a V15.1 Update 4), SIMOCODE ES V16 (Todas las versiones anteriores a V16 Update 1), Soft Starter ES V15.1 (Todas las versiones anteriores a V15.1 Update 3), Soft Starter ES V16 (Todas las versiones anteriores a V16 Update 1). Un componente dentro de la aplicaci\u00f3n afectada llama a un binario de ayuda con privilegios de SISTEMA durante el inicio mientras la ruta de llamada no est\u00e1 citada. Esto podr\u00eda permitir a un atacante local con privilegios administrativos ejecutar c\u00f3digo con privilegios de nivel SYSTEM" } ], "id": "CVE-2020-7581", "lastModified": "2024-11-21T05:37:24.977", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:18.587", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-428" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-428" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-09-14 11:15
Modified
2024-11-21 08:13
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS neo (Administration Console) V4.0 (All versions), SIMATIC PCS neo (Administration Console) V4.0 Update 1 (All versions). The affected application leaks Windows admin credentials. An attacker with local access to the Administration Console could get the credentials, and impersonate the admin user, thereby gaining admin access to other Windows systems.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-646240.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-646240.pdf | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_pcs_neo | 4.0 | |
siemens | simatic_pcs_neo | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:4.0:-:*:*:*:*:*:*", "matchCriteriaId": "DE7A5B02-CA5E-4741-BF1B-CCF52006078B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:4.0:update_1:*:*:*:*:*:*", "matchCriteriaId": "C0EF78CE-A542-4770-9C07-EB328E852400", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS neo (Administration Console) V4.0 (All versions), SIMATIC PCS neo (Administration Console) V4.0 Update 1 (All versions). The affected application leaks Windows admin credentials. An attacker with local access to the Administration Console could get the credentials, and impersonate the admin user, thereby gaining admin access to other Windows systems." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS neo (Consola de administraci\u00f3n) V4.0 (todas las versiones), SIMATIC PCS neo (Consola de administraci\u00f3n) V4.0 Update 1 (todas las versiones). La aplicaci\u00f3n afectada pierde las credenciales de administrador de Windows. Un atacante con acceso local a la Consola de Administraci\u00f3n podr\u00eda obtener las credenciales y hacerse pasar por el usuario administrador, obteniendo as\u00ed acceso de administrador a otros sistemas Windows." } ], "id": "CVE-2023-38558", "lastModified": "2024-11-21T08:13:49.637", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2023-09-14T11:15:07.643", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646240.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646240.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-538" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-668" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-11-14 11:15
Modified
2024-11-21 08:27
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Summary
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly authenticate users in the PUD Manager web service. This could allow an unauthenticated adjacent attacker to generate a privileged token and upload additional documents.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_pcs_neo | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS neo (All versions \u003c V4.1). The PUD Manager of affected products does not properly authenticate users in the PUD Manager web service. This could allow an unauthenticated adjacent attacker to generate a privileged token and upload additional documents." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS neo (todas las versiones \u0026lt; V4.1). El PUD Manager de los productos afectados no autentica adecuadamente a los usuarios en el servicio web PUD Manager. Esto podr\u00eda permitir que un atacante adyacente no autenticado genere un token privilegiado y cargue documentos adicionales." } ], "id": "CVE-2023-46096", "lastModified": "2024-11-21T08:27:53.477", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-11-14T11:15:14.167", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-11-14 11:15
Modified
2024-11-21 08:27
Severity ?
6.3 (Medium) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly neutralize user provided inputs. This could allow an authenticated adjacent attacker to execute SQL statements in the underlying database.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_pcs_neo | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS neo (All versions \u003c V4.1). The PUD Manager of affected products does not properly neutralize user provided inputs. This could allow an authenticated adjacent attacker to execute SQL statements in the underlying database." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS neo (todas las versiones \u0026lt; V4.1). El PUD Manager de los productos afectados no neutraliza adecuadamente las entradas proporcionadas por el usuario. Esto podr\u00eda permitir que un atacante adyacente autenticado ejecute declaraciones SQL en la base de datos subyacente." } ], "id": "CVE-2023-46097", "lastModified": "2024-11-21T08:27:53.600", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 2.1, "impactScore": 4.2, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.0, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.1, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-11-14T11:15:14.360", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-89" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-11-14 21:15
Modified
2024-11-21 06:25
Severity ?
Summary
In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
wibu | codemeter_runtime | * | |
microsoft | windows | - | |
siemens | pss_cape | 14 | |
siemens | pss_e | * | |
siemens | pss_e | * | |
siemens | pss_odms | * | |
siemens | sicam_230 | * | |
siemens | simatic_information_server | * | |
siemens | simatic_information_server | 2019 | |
siemens | simatic_information_server | 2019 | |
siemens | simatic_pcs_neo | * | |
siemens | simatic_process_historian | * | |
siemens | simatic_wincc_oa | * | |
siemens | simit | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:wibu:codemeter_runtime:*:*:*:*:*:*:*:*", "matchCriteriaId": "C8B1884B-18F5-4B92-B83F-C756725FDAB9", "versionEndExcluding": "7.30a", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:pss_cape:14:*:*:*:*:*:*:*", "matchCriteriaId": "76414178-E1E6-40A5-9DD2-FBAD698624C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:pss_e:*:*:*:*:*:*:*:*", "matchCriteriaId": "E01D2F88-8820-49E6-8865-3E20AB63289E", "versionEndExcluding": "34.9.1", "versionStartIncluding": "34.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:pss_e:*:*:*:*:*:*:*:*", "matchCriteriaId": "F42F3EBF-41A9-4F3B-BEED-2954B350E0FA", "versionEndExcluding": "35.3.2", "versionStartIncluding": "35.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:pss_odms:*:*:*:*:*:*:*:*", "matchCriteriaId": "8707B418-2D99-4303-8102-316081B722D4", "versionEndExcluding": "12.2.6.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sicam_230:*:*:*:*:*:*:*:*", "matchCriteriaId": "312E7EA5-61A8-4439-A9E0-87522E8DD141", "versionEndExcluding": "8.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_information_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FD2B7BE-73CA-4974-A61C-3E97FE5A2F7F", "versionEndExcluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_information_server:2019:-:*:*:*:*:*:*", "matchCriteriaId": "4FA3A37A-6A43-42E1-80BF-7FF346D2F253", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_information_server:2019:sp1:*:*:*:*:*:*", "matchCriteriaId": "4BB95C8C-188D-430F-9D59-7F5E1832A0A5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "D61D4B81-7F51-49BE-83DD-D2C28D23B0EA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_process_historian:*:*:*:*:*:*:*:*", "matchCriteriaId": "9A9C8C40-ABBD-496C-BF0B-24098B96D029", "versionEndIncluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_oa:*:*:*:*:*:*:*:*", "matchCriteriaId": "52504DDF-990A-419B-BEAF-E02B4403BBBA", "versionEndIncluding": "3.18", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simit:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE96110F-4874-42C5-A891-FD9022FE7803", "versionEndIncluding": "10.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions." }, { "lang": "es", "value": "En WIBU CodeMeter Runtime versiones anteriores a 7.30a, la creaci\u00f3n de un enlace simb\u00f3lico CmDongles dise\u00f1ado sobrescribir\u00e1 el archivo enlazado sin comprobar los permisos" } ], "id": "CVE-2021-41057", "lastModified": "2024-11-21T06:25:21.627", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 3.6, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-11-14T21:15:07.797", "references": [ { "source": "cve@mitre.org", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.wibu.com/us/support/security-advisories.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.wibu.com/us/support/security-advisories.html" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-59" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-06-10 17:15
Modified
2024-11-21 05:37
Severity ?
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_automatic_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "A659B687-1038-42F5-B8AC-A394E41D22A8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*", "matchCriteriaId": "744B5953-511F-42CA-80A0-DBE36A6AA144", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*", "matchCriteriaId": "496E3C43-5DA8-4983-8AC6-0F32454E22F3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:update1:*:*:*:*:*:*", "matchCriteriaId": "17BCC3CD-61D0-416D-A241-D35AF8EE5BF8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "13E3BDF0-B691-4A97-A74A-A65EC910480E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "D61D4B81-7F51-49BE-83DD-D2C28D23B0EA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_prosave:*:*:*:*:*:*:*:*", "matchCriteriaId": "CB7752CF-D754-4A78-999B-45FE379E03DE", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*", "matchCriteriaId": "658E1A3F-29D6-48D2-BCCE-0BCC41AC49F6", "versionEndExcluding": "21.8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "CAF09D6E-3375-4731-B16D-30B7592EA5FB", "versionEndExcluding": "5.6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "1A3CA33C-AFAB-418F-870F-0236B8E55943", "versionEndIncluding": "16", "versionStartIncluding": "13", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:-:*:*:*:*:*:*", "matchCriteriaId": "851F8474-4568-487D-98FB-47DF7EAEAC3B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp1:*:*:*:*:*:*", "matchCriteriaId": "81EADA2F-884C-4D72-8489-71025B3EBAEE", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp2:*:*:*:*:*:*", "matchCriteriaId": "78366D2F-B728-47F6-B539-5FB2D1B0419D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp2_hotfix1:*:*:*:*:*:*", "matchCriteriaId": "06A86DA0-BC1F-4306-B02E-ED2FA36BE273", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F39B396-140B-4005-9A61-F984C9FAF742", "versionEndExcluding": "7.4", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*", "matchCriteriaId": "3B0BD5DE-C6EF-4B89-831B-DA34DB0D68F6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*", "matchCriteriaId": "2637C346-8AAF-481F-AFB0-BAD4254D14F4", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update1:*:*:*:*:*:*", "matchCriteriaId": "BF8404AB-579E-4C6B-BCA7-E95F2CE24F7D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update10:*:*:*:*:*:*", "matchCriteriaId": "88F6B3BF-727F-432E-89D8-37FB7C76FE2B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update11:*:*:*:*:*:*", "matchCriteriaId": "62EB588C-CBB4-4B17-9BB5-B14B1FC6BB21", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update12:*:*:*:*:*:*", "matchCriteriaId": "AF3F613C-6707-4517-B4B8-530C912B79E6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update13:*:*:*:*:*:*", "matchCriteriaId": "590F62CE-9245-4AC9-9FBC-35136E217B0E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update2:*:*:*:*:*:*", "matchCriteriaId": "241D5A28-FB22-4C5B-A067-733168E847BF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update3:*:*:*:*:*:*", "matchCriteriaId": "A5418F92-84A9-439C-B86C-ED5820697603", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update4:*:*:*:*:*:*", "matchCriteriaId": "40631FBD-116B-4589-B77A-6C5A69990F73", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update5:*:*:*:*:*:*", "matchCriteriaId": "64B14972-6163-4D44-A9C6-16328E02AC69", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update6:*:*:*:*:*:*", "matchCriteriaId": "8929E926-740F-4F17-B52C-4C73914B1818", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update7:*:*:*:*:*:*", "matchCriteriaId": "D4F72666-D10A-4EB2-80D3-18B04C101256", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update8:*:*:*:*:*:*", "matchCriteriaId": "0E343221-1E1A-4EE7-80AE-AB24E2244BA0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update9:*:*:*:*:*:*", "matchCriteriaId": "1BF716D7-0A77-400F-9B43-64FBE3E65735", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*", "matchCriteriaId": "E79DA14E-419C-49BA-8E4F-2907E1D8937F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*", "matchCriteriaId": "81F9C13C-065C-4E40-BB46-687D791348A9", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*", "matchCriteriaId": "5CF06E69-0A23-418D-B0EC-574DACBB4DD9", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*", "matchCriteriaId": "9164EAC1-C416-4F1F-A910-CE84A167A6D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:*:*:*:*:*:*:*", "matchCriteriaId": "4B9ED7EF-EF58-400F-92C9-3D52D8E39783", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.17:*:*:*:*:*:*:*", "matchCriteriaId": "1C3F9210-7A1E-4B10-B384-119FD5733A86", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C9253AD-BD82-4BB2-84AD-EB1892B60358", "versionEndIncluding": "16", "versionStartIncluding": "13", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinamics_startdrive:*:*:*:*:*:*:*:*", "matchCriteriaId": "C11DB09A-74E1-45EF-A162-9C1E91F54C04", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinamics_starter_commissioning_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "1976CDDA-F2AF-4C47-804E-2C1DF44FBF41", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_network_management_system:*:*:*:*:*:*:*:*", "matchCriteriaId": "52F7076E-12F7-4F62-9804-18598C39D3FF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "C55DA617-6333-40DA-AB7D-EE49A453E143", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_one_virtual:*:*:*:*:*:*:*:*", "matchCriteriaId": "A607E4B7-2F58-4F68-91EB-16874986E92F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_operate:*:*:*:*:*:*:*:*", "matchCriteriaId": "BAFC5C25-EC3C-4EB6-B5B2-478AE9CEF10F", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC Automation Tool (Todas las versiones anteriores a la versi\u00f3n V4 SP2), SIMATIC NET PC Software V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a la versi\u00f3n V16 Upd3), SIMATIC PCS neo (Todas las versiones anteriores a la versi\u00f3n V3.0 SP1), SIMATIC ProSave (Todas las versiones anteriores a la versi\u00f3n V17), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a la versi\u00f3n V21. 8), SIMATIC STEP 7 (Todas las versiones anteriores a la versi\u00f3n V5.6 SP2 HF3), SIMATIC STEP 7 (TIA Portal) V13 (Todas las versiones anteriores a la versi\u00f3n V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a la versi\u00f3n V15. 1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC OA V3.16 (Todas las versiones anteriores a la versi\u00f3n V3.16 P018), SIMATIC WinCC OA V3. 17 (Todas las versiones anteriores a la versi\u00f3n V3.17 P003), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC Runtime Professional V13 (Todas las versiones anteriores a la versi\u00f3n V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (Todas las versiones anteriores a la versi\u00f3n V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC V7. 4 (Todas las versiones anteriores a la versi\u00f3n V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versi\u00f3n V7.5 SP1 Update 3), SINAMICS STARTER (Todas las versiones anteriores a la versi\u00f3n V5.4 HF2), SINAMICS Startdrive (Todas las versiones anteriores a la versi\u00f3n V16 Update 3), SINEC NMS (Todas las versiones anteriores a la versi\u00f3n V1. 0 SP2), SINEMA Server (Todas las versiones anteriores a la versi\u00f3n V14 SP3), SINUMERIK ONE virtual (Todas las versiones anteriores a la versi\u00f3n V6.14), SINUMERIK Operate (Todas las versiones anteriores a la versi\u00f3n V6.14). Un componente dentro de la aplicaci\u00f3n afectada llama regularmente a un binario de ayuda con privilegios de SISTEMA mientras la ruta de llamada no est\u00e1 citada" } ], "id": "CVE-2020-7580", "lastModified": "2024-11-21T05:37:24.840", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-10T17:15:12.347", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-428" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-428" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-12-12 12:15
Modified
2024-11-21 08:28
Severity ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*", "matchCriteriaId": "D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "29E53F22-9086-40A2-85E0-20B58EC1E4BB", "versionEndExcluding": "15", "versionStartIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8", "versionEndExcluding": "16", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCF747-13ED-4AE7-9BE7-37858573AF27", "versionEndExcluding": "17", "versionStartIncluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "C83587B9-53E2-4B2F-9FE4-5DDD232571F6", "versionEndExcluding": "18", "versionStartIncluding": "17", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*", "matchCriteriaId": "085B0B91-40DE-4328-A28C-1C920A6440D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*", "matchCriteriaId": "68C7D9A3-9304-4A81-A970-717E5BA1ECF1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*", "matchCriteriaId": "6A09C712-871D-4A81-A630-33BC5DF49FE5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en:\nOpcenter Quality (todas las versiones), \nSIMATIC PCS neo (todas las versiones \u0026lt; V4.1), \nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones " } ], "id": "CVE-2023-46283", "lastModified": "2024-11-21T08:28:13.617", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2023-12-12T12:15:14.067", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-06-16 12:15
Modified
2024-11-21 05:45
Severity ?
Summary
A buffer over-read vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:wibu:codemeter:*:*:*:*:*:*:*:*", "matchCriteriaId": "703D0DCC-23C2-4E57-A273-B6BDA05D424C", "versionEndIncluding": "7.21a", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:pss_cape:-:*:*:*:*:*:*:*", "matchCriteriaId": "890BA38B-38CD-4B6D-96E8-A786CFFE4C35", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_230_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A559DA1A-EB9D-4F93-9649-D69BF916BEE4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_230:-:*:*:*:*:*:*:*", "matchCriteriaId": "702949EB-ED2D-4E85-802B-93EEA4FA939E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_information_server:2019:sp1:*:*:*:*:*:*", "matchCriteriaId": "4BB95C8C-188D-430F-9D59-7F5E1832A0A5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_information_server:2020:-:*:*:*:*:*:*", "matchCriteriaId": "EBF9131D-6408-443C-9322-2E31B1A87CB0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "884EC00C-1155-436D-94F4-C6F2303732CF", "versionEndExcluding": "3.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_oa:3.17:-:*:*:*:*:*:*", "matchCriteriaId": "305D0C1C-16AF-4011-B449-F266FFA6FA3B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_oa:3.18:-:*:*:*:*:*:*", "matchCriteriaId": "2832A89E-57BE-4BB2-94AC-17DC3CFD91FA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simit_simulation_platform:*:*:*:*:*:*:*:*", "matchCriteriaId": "64235511-8464-440C-ACD4-B3D046552735", "versionEndExcluding": "10.3", "versionStartIncluding": "10.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simit_simulation_platform:10.3:-:*:*:*:*:*:*", "matchCriteriaId": "2603C1BD-9B47-4936-B1D2-6D425B764B81", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_infrastructure_network_services:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0F46497-4AB0-49A7-9453-CC26837BF253", "versionEndExcluding": "1.0.1.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_infrastructure_network_services:1.0.1:-:*:*:*:*:*:*", "matchCriteriaId": "5145C088-C0B0-44EB-A852-74695BCF3806", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "F65F9901-F4BD-4484-9749-D5022245D686", "versionEndExcluding": "3.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:3.0:-:*:*:*:*:*:*", "matchCriteriaId": "4F03BAD5-7B90-4212-ACBC-3C878C02CDAA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:3.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "E5BACE03-50A7-4279-8CA5-2BB95224D485", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:simatic_process_historian:*:*:*:*:*:*:*:*", "matchCriteriaId": "73659BCA-7F7A-45D4-AB01-07932B16EA59", "versionEndExcluding": "2020", "versionStartIncluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:simatic_process_historian:2020:-:*:*:*:*:*:*", "matchCriteriaId": "C5DB15E6-296B-48DE-945E-48196595B58B", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A buffer over-read vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de lectura excesiva del b\u00fafer en Wibu-Systems CodeMeter versiones anteriores a 7.21a. Un atacante remoto no autenticado puede explotar este problema para revelar el contenido de la memoria de la pila o bloquear el CodeMeter Runtime Server" } ], "id": "CVE-2021-20093", "lastModified": "2024-11-21T05:45:54.840", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-06-16T12:15:12.037", "references": [ { "source": "vulnreport@tenable.com", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-01.pdf" }, { "source": "vulnreport@tenable.com", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "source": "vulnreport@tenable.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02" }, { "source": "vulnreport@tenable.com", "tags": [ "Exploit", "Patch", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-24" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-01.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Patch", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-24" } ], "sourceIdentifier": "vulnreport@tenable.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-12-12 12:15
Modified
2024-11-21 08:28
Severity ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*", "matchCriteriaId": "D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "29E53F22-9086-40A2-85E0-20B58EC1E4BB", "versionEndExcluding": "15", "versionStartIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8", "versionEndExcluding": "16", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCF747-13ED-4AE7-9BE7-37858573AF27", "versionEndExcluding": "17", "versionStartIncluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "C83587B9-53E2-4B2F-9FE4-5DDD232571F6", "versionEndExcluding": "18", "versionStartIncluding": "17", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*", "matchCriteriaId": "085B0B91-40DE-4328-A28C-1C920A6440D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*", "matchCriteriaId": "68C7D9A3-9304-4A81-A970-717E5BA1ECF1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*", "matchCriteriaId": "6A09C712-871D-4A81-A630-33BC5DF49FE5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en:\nOpcenter Quality (todas las versiones), \nSIMATIC PCS neo (todas las versiones \u0026lt; V4.1), \nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones " } ], "id": "CVE-2023-46284", "lastModified": "2024-11-21T08:28:13.760", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2023-12-12T12:15:14.273", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-04-12 09:15
Modified
2024-11-21 06:55
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions < V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf | Mitigation, Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf | Mitigation, Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_pcs_neo | * | |
siemens | simatic_pcs_neo | 3.1 | |
siemens | sinetplan | * | |
siemens | totally_integrated_automation_portal | 15 | |
siemens | totally_integrated_automation_portal | 15.1 | |
siemens | totally_integrated_automation_portal | 16 | |
siemens | totally_integrated_automation_portal | 17 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "884EC00C-1155-436D-94F4-C6F2303732CF", "versionEndExcluding": "3.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:3.1:-:*:*:*:*:*:*", "matchCriteriaId": "69A8C49A-3AFD-4693-BE59-B3C75D5026E3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinetplan:*:*:*:*:*:*:*:*", "matchCriteriaId": "73C56997-3D1D-435A-8B1C-DC1023CE5715", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:15:*:*:*:*:*:*:*", "matchCriteriaId": "A5BC801E-9D78-4CD4-A457-00ABD5991515", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "C36F0E09-C1BB-4ED2-9008-99DC761FDFAA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*", "matchCriteriaId": "2E1E7FB1-03AF-4AF0-B1A6-3AF65C818596", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:17:*:*:*:*:*:*:*", "matchCriteriaId": "7E0C3283-1FEA-4054-9D48-5F683FA9E4FF", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions \u003c V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS neo (Consola de Administraci\u00f3n) (todas las versiones anteriores a V3.1 SP1), SINETPLAN (Todas las versiones), TIA Portal (versiones V15, V15.1, V16 y V17). El sistema afectado no puede procesar correctamente los paquetes especialmente dise\u00f1ados enviados al puerto 8888/tcp. Un atacante remoto podr\u00eda aprovechar esta vulnerabilidad para causar una condici\u00f3n de denegaci\u00f3n de servicio. Los dispositivos afectados deben reiniciarse manualmente" } ], "id": "CVE-2022-27194", "lastModified": "2024-11-21T06:55:23.107", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-04-12T09:15:15.017", "references": [ { "source": "productcert@siemens.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-11-14 11:15
Modified
2024-11-21 08:27
Severity ?
5.4 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Summary
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). There is a stored cross-site scripting vulnerability in the Administration Console of the affected product, that could allow an attacker with high privileges to inject Javascript code into the application that is later executed by another legitimate user.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_pcs_neo | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS neo (All versions \u003c V4.1). There is a stored cross-site scripting vulnerability in the Administration Console of the affected product, that could allow an attacker with high privileges to inject Javascript code into the application that is later executed by another legitimate user." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS neo (todas las versiones \u0026lt; V4.1). Existe una vulnerabilidad de cross-site scripting almacenada en la Consola de Administraci\u00f3n del producto afectado, que podr\u00eda permitir a un atacante con altos privilegios inyectar c\u00f3digo Javascript en la aplicaci\u00f3n que luego ser\u00e1 ejecutado por otro usuario leg\u00edtimo." } ], "id": "CVE-2023-46099", "lastModified": "2024-11-21T08:27:53.853", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 3.7, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-11-14T11:15:14.840", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-12-12 12:15
Modified
2024-11-21 08:28
Severity ?
7.1 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*", "matchCriteriaId": "D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "29E53F22-9086-40A2-85E0-20B58EC1E4BB", "versionEndExcluding": "15", "versionStartIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8", "versionEndExcluding": "16", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCF747-13ED-4AE7-9BE7-37858573AF27", "versionEndExcluding": "17", "versionStartIncluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "C83587B9-53E2-4B2F-9FE4-5DDD232571F6", "versionEndExcluding": "18", "versionStartIncluding": "17", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*", "matchCriteriaId": "085B0B91-40DE-4328-A28C-1C920A6440D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*", "matchCriteriaId": "68C7D9A3-9304-4A81-A970-717E5BA1ECF1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*", "matchCriteriaId": "6A09C712-871D-4A81-A630-33BC5DF49FE5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en:\nOpcenter Quality (todas las versiones), \nSIMATIC PCS neo (todas las versiones \u0026lt; V4.1), \nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones " } ], "id": "CVE-2023-46282", "lastModified": "2024-11-21T08:28:13.473", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 1.6, "impactScore": 5.5, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-12-12T12:15:13.870", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-12-12 12:15
Modified
2024-11-21 08:28
Severity ?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*", "matchCriteriaId": "D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "29E53F22-9086-40A2-85E0-20B58EC1E4BB", "versionEndExcluding": "15", "versionStartIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8", "versionEndExcluding": "16", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCF747-13ED-4AE7-9BE7-37858573AF27", "versionEndExcluding": "17", "versionStartIncluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "C83587B9-53E2-4B2F-9FE4-5DDD232571F6", "versionEndExcluding": "18", "versionStartIncluding": "17", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*", "matchCriteriaId": "085B0B91-40DE-4328-A28C-1C920A6440D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*", "matchCriteriaId": "68C7D9A3-9304-4A81-A970-717E5BA1ECF1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*", "matchCriteriaId": "6A09C712-871D-4A81-A630-33BC5DF49FE5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en:\nOpcenter Quality (todas las versiones), \nSIMATIC PCS neo (todas las versiones \u0026lt; V4.1), \nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones " } ], "id": "CVE-2023-46285", "lastModified": "2024-11-21T08:28:13.877", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2023-12-12T12:15:14.477", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-12-12 12:15
Modified
2024-11-21 08:28
Severity ?
7.1 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", "versionEndExcluding": "4.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*", "matchCriteriaId": "D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "29E53F22-9086-40A2-85E0-20B58EC1E4BB", "versionEndExcluding": "15", "versionStartIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8", "versionEndExcluding": "16", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCF747-13ED-4AE7-9BE7-37858573AF27", "versionEndExcluding": "17", "versionStartIncluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "matchCriteriaId": "C83587B9-53E2-4B2F-9FE4-5DDD232571F6", "versionEndExcluding": "18", "versionStartIncluding": "17", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*", "matchCriteriaId": "085B0B91-40DE-4328-A28C-1C920A6440D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*", "matchCriteriaId": "68C7D9A3-9304-4A81-A970-717E5BA1ECF1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*", "matchCriteriaId": "6A09C712-871D-4A81-A630-33BC5DF49FE5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en:\nOpcenter Quality (todas las versiones), \nSIMATIC PCS neo (todas las versiones \u0026lt; V4.1), \nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones " } ], "id": "CVE-2023-46281", "lastModified": "2024-11-21T08:28:13.317", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 1.6, "impactScore": 5.5, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-12-12T12:15:13.653", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-942" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 05:37
Severity ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:*", "matchCriteriaId": "F33BF89C-F36E-4C8F-ABB9-579E2022DDA6", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DCE5E06-B75F-4D21-96CC-70DD373B1811", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4DD5C57-5877-495C-A01E-747E5DCED9F7", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*", "matchCriteriaId": "E927136F-3870-47AD-BE56-C83FBD7BB7E9", "versionEndExcluding": "3.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*", "matchCriteriaId": "9DB2F53B-817C-41F3-9B52-85DE702ACCE5", "versionEndExcluding": "11.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_rd\\\u0026l:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "EE037602-C9E8-45D5-9A44-3B73052F478E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_lms:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F8E56A4-77DB-4938-93E5-2CA22222FD6A", "versionEndExcluding": "2.6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_production_suite:*:*:*:*:*:*:*:*", "matchCriteriaId": "218D5A8B-FC2D-440C-B853-35E93A025A6E", "versionEndExcluding": "8.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*", "matchCriteriaId": "DE74021F-CE57-42CC-8093-E1B0352410FA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "32A732D2-5E9E-4C8B-93C1-2E0BEBA7B327", "versionEndExcluding": "3.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:3.0:-:*:*:*:*:*:*", "matchCriteriaId": "B275D75A-1869-4660-A1FF-837A9C0F874B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "6729BE2B-6729-4041-BC8C-2AD039467B9A", "versionEndExcluding": "15.1", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "C470C8EF-BBF5-4940-944E-2460BA6D8A27", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*", "matchCriteriaId": "66CB66B9-176E-4FA3-BC67-E7C5972A307C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*", "matchCriteriaId": "EF2D6947-576B-4CA7-B4E4-F0B428FA5ABB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "098E9BE1-D698-4DE5-96C1-DF0B3806C935", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simocode_es:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "8DA3C5DB-8D27-4CDD-AA93-ABE1EE021CAF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simocode_es:16:-:*:*:*:*:*:*", "matchCriteriaId": "8829878A-34E1-44D5-B4BC-12CF67CB58C2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1E0C95F-8201-4F04-99A6-62B9684BF35F", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:soft_starter_es:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "7039A3C6-5DE3-4980-8A2F-A05928561673", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Opcenter Execution Discrete (Todas las versiones anteriores a V3.2), Opcenter Execution Foundation (Todas las versiones anteriores a V3.2), Opcenter Execution Process (Todas las versiones anteriores a V3.2), Opcenter Intelligence (Todas las versiones anteriores a V3.3), Opcenter Quality (Todas las versiones anteriores a V11.3), Opcenter RD\u0026amp;L (V8.0), SIMATIC IT LMS (Todas las versiones anteriores a V2.6), SIMATIC IT Production Suite (Todas las versiones anteriores a V8. 0), SIMATIC Notifier Server for Windows (Todas las versiones), SIMATIC PCS neo (Todas las versiones anteriores a V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a V16 Update 2), SIMOCODE ES V15. 1 (Todas las versiones anteriores a V15.1 Update 4), SIMOCODE ES V16 (Todas las versiones anteriores a V16 Update 1), Soft Starter ES V15.1 (Todas las versiones anteriores a V15.1 Update 3), Soft Starter ES V16 (Todas las versiones anteriores a V16 Update 1). El env\u00edo de m\u00faltiples paquetes especialmente dise\u00f1ados al servicio afectado podr\u00eda causar una denegaci\u00f3n de servicio remota parcial, que har\u00eda que el servicio se reiniciara. En algunos casos la vulnerabilidad podr\u00eda filtrar informaci\u00f3n aleatoria del servicio remoto" } ], "id": "CVE-2020-7587", "lastModified": "2024-11-21T05:37:25.533", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 4.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:18.930", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }