Search criteria

5 vulnerabilities by C-MORE

CVE-2020-10922 (GCVE-0-2020-10922)

Vulnerability from cvelistv5 – Published: 2020-07-23 15:35 – Updated: 2024-08-04 11:14
VLAI?
Summary
This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of proper input validation prior to further processing user requests. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-10527.
CWE
  • CWE-20 - Improper Input Validation
Assigner
zdi
References
Impacted products
Vendor Product Version
C-MORE HMI EA9 Affected: Firmware version 6.52
Create a notification for this product.
Credits
evanslify
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:14:15.785Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-809/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HMI EA9",
          "vendor": "C-MORE",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware version 6.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "evanslify"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of proper input validation prior to further processing user requests. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-10527."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-23T15:35:20",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-809/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2020-10922",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HMI EA9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Firmware version 6.52"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "C-MORE"
              }
            ]
          }
        },
        "credit": "evanslify",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of proper input validation prior to further processing user requests. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-10527."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-20: Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-20-809/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-809/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2020-10922",
    "datePublished": "2020-07-23T15:35:20",
    "dateReserved": "2020-03-24T00:00:00",
    "dateUpdated": "2024-08-04T11:14:15.785Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10921 (GCVE-0-2020-10921)

Vulnerability from cvelistv5 – Published: 2020-07-23 15:35 – Updated: 2024-08-04 11:14
VLAI?
Summary
This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to issue commands to the physical equipment controlled by the device. Was ZDI-CAN-10482.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
zdi
References
Impacted products
Vendor Product Version
C-MORE HMI EA9 Affected: Firmware version 6.52
Create a notification for this product.
Credits
Ta-Lun Yen & Chizuru Toyama of TXOne IoT/ICS Security Research Labs (Trend Micro)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:14:15.689Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-807/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HMI EA9",
          "vendor": "C-MORE",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware version 6.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Ta-Lun Yen \u0026 Chizuru Toyama of TXOne IoT/ICS Security Research Labs (Trend Micro)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to issue commands to the physical equipment controlled by the device. Was ZDI-CAN-10482."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-23T15:35:19",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-807/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2020-10921",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HMI EA9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Firmware version 6.52"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "C-MORE"
              }
            ]
          }
        },
        "credit": "Ta-Lun Yen \u0026 Chizuru Toyama of TXOne IoT/ICS Security Research Labs (Trend Micro)",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to issue commands to the physical equipment controlled by the device. Was ZDI-CAN-10482."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-20-807/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-807/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2020-10921",
    "datePublished": "2020-07-23T15:35:19",
    "dateReserved": "2020-03-24T00:00:00",
    "dateUpdated": "2024-08-04T11:14:15.689Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10920 (GCVE-0-2020-10920)

Vulnerability from cvelistv5 – Published: 2020-07-23 15:35 – Updated: 2024-08-04 11:14
VLAI?
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the control service, which listens on TCP port 9999 by default. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-10493.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
zdi
References
Impacted products
Vendor Product Version
C-MORE HMI EA9 Affected: Firmware version 6.52
Create a notification for this product.
Credits
Ta-Lun Yen & Chizuru Toyama of TXOne IoT/ICS Security Research Labs (Trend Micro)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:14:15.788Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-808/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HMI EA9",
          "vendor": "C-MORE",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware version 6.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Ta-Lun Yen \u0026 Chizuru Toyama of TXOne IoT/ICS Security Research Labs (Trend Micro)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the control service, which listens on TCP port 9999 by default. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-10493."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-23T15:35:19",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-808/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2020-10920",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HMI EA9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Firmware version 6.52"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "C-MORE"
              }
            ]
          }
        },
        "credit": "Ta-Lun Yen \u0026 Chizuru Toyama of TXOne IoT/ICS Security Research Labs (Trend Micro)",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the control service, which listens on TCP port 9999 by default. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-10493."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-20-808/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-808/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2020-10920",
    "datePublished": "2020-07-23T15:35:19",
    "dateReserved": "2020-03-24T00:00:00",
    "dateUpdated": "2024-08-04T11:14:15.788Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10919 (GCVE-0-2020-10919)

Vulnerability from cvelistv5 – Published: 2020-07-23 15:35 – Updated: 2024-08-04 11:14
VLAI?
Summary
This vulnerability allows remote attackers to disclose sensitive information on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of passwords. When transmitting passwords, the process encrypts them in a recoverable format. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-10185.
CWE
  • CWE-261 - Weak Cryptography for Passwords
Assigner
zdi
References
Impacted products
Vendor Product Version
C-MORE HMI EA9 Affected: Firmware version 6.52
Create a notification for this product.
Credits
Ta-Lun Yen & Chizuru Toyama of TXOne IoT/ICS Security Research Labs (Trend Micro)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:14:15.726Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-806/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HMI EA9",
          "vendor": "C-MORE",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware version 6.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Ta-Lun Yen \u0026 Chizuru Toyama of TXOne IoT/ICS Security Research Labs (Trend Micro)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of passwords. When transmitting passwords, the process encrypts them in a recoverable format. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-10185."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-261",
              "description": "CWE-261: Weak Cryptography for Passwords",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-26T21:30:13",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-806/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2020-10919",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HMI EA9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Firmware version 6.52"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "C-MORE"
              }
            ]
          }
        },
        "credit": "Ta-Lun Yen \u0026 Chizuru Toyama of TXOne IoT/ICS Security Research Labs (Trend Micro)",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of passwords. When transmitting passwords, the process encrypts them in a recoverable format. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-10185."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-261: Weak Cryptography for Passwords"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-20-806/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-806/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2020-10919",
    "datePublished": "2020-07-23T15:35:18",
    "dateReserved": "2020-03-24T00:00:00",
    "dateUpdated": "2024-08-04T11:14:15.726Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10918 (GCVE-0-2020-10918)

Vulnerability from cvelistv5 – Published: 2020-07-23 15:35 – Updated: 2024-08-04 11:14
VLAI?
Summary
This vulnerability allows remote attackers to bypass authentication on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the authentication mechanism. The issue is due to insufficient authentication on post-authentication requests. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from unauthenticated users. Was ZDI-CAN-10182.
CWE
  • CWE-287 - Improper Authentication
Assigner
zdi
References
Impacted products
Vendor Product Version
C-MORE HMI EA9 Affected: Firmware version 6.52
Create a notification for this product.
Credits
Anonymous
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:14:15.682Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-805/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HMI EA9",
          "vendor": "C-MORE",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware version 6.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Anonymous"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to bypass authentication on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the authentication mechanism. The issue is due to insufficient authentication on post-authentication requests. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from unauthenticated users. Was ZDI-CAN-10182."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-23T15:35:18",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-805/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2020-10918",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HMI EA9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Firmware version 6.52"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "C-MORE"
              }
            ]
          }
        },
        "credit": "Anonymous",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to bypass authentication on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the authentication mechanism. The issue is due to insufficient authentication on post-authentication requests. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from unauthenticated users. Was ZDI-CAN-10182."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287: Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-20-805/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-805/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2020-10918",
    "datePublished": "2020-07-23T15:35:18",
    "dateReserved": "2020-03-24T00:00:00",
    "dateUpdated": "2024-08-04T11:14:15.682Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}