Search criteria
13 vulnerabilities by Cognex
CVE-2025-53969 (GCVE-0-2025-53969)
Vulnerability from cvelistv5 – Published: 2025-09-18 21:30 – Updated: 2025-09-19 13:10
VLAI?
Title
Cognex In-Sight Explorer and In-Sight Camera Firmware Client-Side Enforcement of Server-Side Security
Summary
Cognex In-Sight Explorer and In-Sight Camera Firmware expose
a service implementing a proprietary protocol on TCP port 1069 to allow
the client-side software, such as the In-Sight Explorer tool, to perform
management operations such as changing network settings or modifying
users' access to the device.
Severity ?
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cognex | In-Sight 2000 series |
Affected:
5.x , ≤ 6.5.1
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-53969",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-19T13:10:53.059220Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-19T13:10:58.750Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "In-Sight 2000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 7000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 8000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 9000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight Explorer",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cognex In-Sight Explorer and In-Sight Camera Firmware expose \na service implementing a proprietary protocol on TCP port 1069 to allow \nthe client-side software, such as the In-Sight Explorer tool, to perform\n management operations such as changing network settings or modifying \nusers\u0027 access to the device."
}
],
"value": "Cognex In-Sight Explorer and In-Sight Camera Firmware expose \na service implementing a proprietary protocol on TCP port 1069 to allow \nthe client-side software, such as the In-Sight Explorer tool, to perform\n management operations such as changing network settings or modifying \nusers\u0027 access to the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-602",
"description": "CWE-602",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-18T21:30:45.520Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-06"
}
],
"source": {
"advisory": "ICSA-25-261-06",
"discovery": "EXTERNAL"
},
"title": "Cognex In-Sight Explorer and In-Sight Camera Firmware Client-Side Enforcement of Server-Side Security",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras.\n\n\u003cbr\u003e"
}
],
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-53969",
"datePublished": "2025-09-18T21:30:45.520Z",
"dateReserved": "2025-08-06T16:32:41.324Z",
"dateUpdated": "2025-09-19T13:10:58.750Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-54810 (GCVE-0-2025-54810)
Vulnerability from cvelistv5 – Published: 2025-09-18 21:28 – Updated: 2025-09-19 13:11
VLAI?
Title
Cognex In-Sight Explorer and In-Sight Camera Firmware Authentication Bypass by Capture-replay
Summary
Cognex In-Sight Explorer and In-Sight Camera Firmware expose
a proprietary protocol on TCP port 1069 to perform management operations
such as modifying system properties. The user management functionality
handles sensitive data such as registered usernames and passwords over
an unencrypted channel, allowing an adjacent attacker to intercept valid
credentials to gain access to the device.
Severity ?
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cognex | In-Sight 2000 series |
Affected:
5.x , ≤ 6.5.1
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54810",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-19T13:11:28.075498Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-19T13:11:33.376Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "In-Sight 2000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 7000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 8000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 9000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight Explorer",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cognex In-Sight Explorer and In-Sight Camera Firmware expose \n\na proprietary protocol on TCP port 1069 to perform management operations\n such as modifying system properties. The user management functionality \nhandles sensitive data such as registered usernames and passwords over \nan unencrypted channel, allowing an adjacent attacker to intercept valid\n credentials to gain access to the device."
}
],
"value": "Cognex In-Sight Explorer and In-Sight Camera Firmware expose \n\na proprietary protocol on TCP port 1069 to perform management operations\n such as modifying system properties. The user management functionality \nhandles sensitive data such as registered usernames and passwords over \nan unencrypted channel, allowing an adjacent attacker to intercept valid\n credentials to gain access to the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-294",
"description": "CWE-294",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-18T21:28:19.297Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-06"
}
],
"source": {
"advisory": "ICSA-25-261-06",
"discovery": "EXTERNAL"
},
"title": "Cognex In-Sight Explorer and In-Sight Camera Firmware Authentication Bypass by Capture-replay",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras.\n\n\u003cbr\u003e"
}
],
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-54810",
"datePublished": "2025-09-18T21:28:19.297Z",
"dateReserved": "2025-08-06T16:32:41.319Z",
"dateUpdated": "2025-09-19T13:11:33.376Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-54818 (GCVE-0-2025-54818)
Vulnerability from cvelistv5 – Published: 2025-09-18 21:26 – Updated: 2025-09-19 13:12
VLAI?
Title
Cognex In-Sight Explorer and In-Sight Camera Firmware Cleartext Transmission of Sensitive Information
Summary
Cognex In-Sight Explorer and In-Sight Camera Firmware expose
a proprietary protocol on TCP port 1069 to perform management operations
such as modifying system properties. The user management functionality
handles sensitive data such as registered usernames and passwords over
an unencrypted channel, allowing an adjacent attacker to intercept valid
credentials to gain access to the device.
Severity ?
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cognex | In-Sight 2000 series |
Affected:
5.x , ≤ 6.5.1
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54818",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-19T13:11:59.186520Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-19T13:12:06.509Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "In-Sight 2000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 7000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 8000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 9000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight Explorer",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cognex In-Sight Explorer and In-Sight Camera Firmware expose \n\na proprietary protocol on TCP port 1069 to perform management operations\n such as modifying system properties. The user management functionality \nhandles sensitive data such as registered usernames and passwords over \nan unencrypted channel, allowing an adjacent attacker to intercept valid\n credentials to gain access to the device."
}
],
"value": "Cognex In-Sight Explorer and In-Sight Camera Firmware expose \n\na proprietary protocol on TCP port 1069 to perform management operations\n such as modifying system properties. The user management functionality \nhandles sensitive data such as registered usernames and passwords over \nan unencrypted channel, allowing an adjacent attacker to intercept valid\n credentials to gain access to the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-18T21:26:45.354Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-06"
}
],
"source": {
"advisory": "ICSA-25-261-06",
"discovery": "EXTERNAL"
},
"title": "Cognex In-Sight Explorer and In-Sight Camera Firmware Cleartext Transmission of Sensitive Information",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras.\n\n\u003cbr\u003e"
}
],
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-54818",
"datePublished": "2025-09-18T21:26:45.354Z",
"dateReserved": "2025-08-06T16:32:41.313Z",
"dateUpdated": "2025-09-19T13:12:06.509Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-54497 (GCVE-0-2025-54497)
Vulnerability from cvelistv5 – Published: 2025-09-18 21:24 – Updated: 2025-09-19 13:12
VLAI?
Title
Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource
Summary
Cognex In-Sight Explorer and In-Sight Camera Firmware expose
a telnet-based service
on port 23 to allow management operations such as firmware upgrades and
device reboots, which require authentication. A user with protected
privileges can successfully invoke the SetSerialPort functionality to
modify relevant device properties (such as serial interface settings),
contradicting the security model proposed in the user manual.
Severity ?
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cognex | In-Sight 2000 series |
Affected:
5.x , ≤ 6.5.1
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54497",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-19T13:12:33.199419Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-19T13:12:37.793Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "In-Sight 2000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 7000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 8000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 9000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight Explorer",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cognex In-Sight Explorer and In-Sight Camera Firmware expose \na telnet-based service \non port 23 to allow management operations such as firmware upgrades and \ndevice reboots, which require authentication. A user with protected \nprivileges can successfully invoke the SetSerialPort functionality to \nmodify relevant device properties (such as serial interface settings), \ncontradicting the security model proposed in the user manual."
}
],
"value": "Cognex In-Sight Explorer and In-Sight Camera Firmware expose \na telnet-based service \non port 23 to allow management operations such as firmware upgrades and \ndevice reboots, which require authentication. A user with protected \nprivileges can successfully invoke the SetSerialPort functionality to \nmodify relevant device properties (such as serial interface settings), \ncontradicting the security model proposed in the user manual."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-18T21:24:05.023Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-06"
}
],
"source": {
"advisory": "ICSA-25-261-06",
"discovery": "EXTERNAL"
},
"title": "Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras.\n\n\u003cbr\u003e"
}
],
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-54497",
"datePublished": "2025-09-18T21:24:05.023Z",
"dateReserved": "2025-08-06T16:32:41.300Z",
"dateUpdated": "2025-09-19T13:12:37.793Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-52873 (GCVE-0-2025-52873)
Vulnerability from cvelistv5 – Published: 2025-09-18 21:22 – Updated: 2025-09-19 13:15
VLAI?
Title
Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource
Summary
Cognex In-Sight Explorer and In-Sight Camera Firmware expose
a telnet-based service on port 23 to allow management operations such as
firmware upgrades and device reboots, which require authentication. A
user with protected privileges can successfully invoke the
SetSystemConfig functionality to modify relevant device properties (such
as network settings), contradicting the security model proposed in the
user manual.
Severity ?
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cognex | In-Sight 2000 series |
Affected:
5.x , ≤ 6.5.1
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-52873",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-19T13:15:12.315307Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-19T13:15:17.771Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "In-Sight 2000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 7000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 8000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 9000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight Explorer",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cognex In-Sight Explorer and In-Sight Camera Firmware expose \na telnet-based service on port 23 to allow management operations such as\n firmware upgrades and device reboots, which require authentication. A \nuser with protected privileges can successfully invoke the \nSetSystemConfig functionality to modify relevant device properties (such\n as network settings), contradicting the security model proposed in the \nuser manual."
}
],
"value": "Cognex In-Sight Explorer and In-Sight Camera Firmware expose \na telnet-based service on port 23 to allow management operations such as\n firmware upgrades and device reboots, which require authentication. A \nuser with protected privileges can successfully invoke the \nSetSystemConfig functionality to modify relevant device properties (such\n as network settings), contradicting the security model proposed in the \nuser manual."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-18T21:22:38.150Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-06"
}
],
"source": {
"advisory": "ICSA-25-261-06",
"discovery": "EXTERNAL"
},
"title": "Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras.\n\n\u003cbr\u003e"
}
],
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-52873",
"datePublished": "2025-09-18T21:22:38.150Z",
"dateReserved": "2025-08-06T16:32:41.292Z",
"dateUpdated": "2025-09-19T13:15:17.771Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-54860 (GCVE-0-2025-54860)
Vulnerability from cvelistv5 – Published: 2025-09-18 21:20 – Updated: 2025-09-19 13:15
VLAI?
Title
Cognex In-Sight Explorer and In-Sight Camera Firmware Improper Restriction of Excessive Authentication Attempts
Summary
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 in order to allow
management operations on the device such as firmware upgrades and device
reboot requiring an authentication. A wrong management of login
failures of the service allows a denial-of-service attack, leaving the telnet service
into an unreachable state.
Severity ?
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cognex | In-Sight 2000 series |
Affected:
5.x , ≤ 6.5.1
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54860",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-19T13:15:34.752454Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-19T13:15:40.179Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "In-Sight 2000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 7000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 8000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 9000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight Explorer",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 in order to allow \nmanagement operations on the device such as firmware upgrades and device\n reboot requiring an authentication. A wrong management of login \nfailures of the service allows a denial-of-service attack, leaving the telnet service \ninto an unreachable state."
}
],
"value": "Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 in order to allow \nmanagement operations on the device such as firmware upgrades and device\n reboot requiring an authentication. A wrong management of login \nfailures of the service allows a denial-of-service attack, leaving the telnet service \ninto an unreachable state."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-18T21:20:20.243Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-06"
}
],
"source": {
"advisory": "ICSA-25-261-06",
"discovery": "EXTERNAL"
},
"title": "Cognex In-Sight Explorer and In-Sight Camera Firmware Improper Restriction of Excessive Authentication Attempts",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras.\n\n\u003cbr\u003e"
}
],
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-54860",
"datePublished": "2025-09-18T21:20:20.243Z",
"dateReserved": "2025-08-06T16:32:41.284Z",
"dateUpdated": "2025-09-19T13:15:40.179Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-53947 (GCVE-0-2025-53947)
Vulnerability from cvelistv5 – Published: 2025-09-18 21:10 – Updated: 2025-09-19 12:10
VLAI?
Title
Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Default Permissions
Summary
A local attacker with low privileges on the Windows system where the
software is installed can exploit this vulnerability to corrupt
sensitive data. A data folder is created with very weak privileges,
allowing any user logged into the Windows system to modify its content.
Severity ?
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cognex | In-Sight 2000 series |
Affected:
5.x , ≤ 6.5.1
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-53947",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-19T12:09:45.113789Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-19T12:10:31.664Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "In-Sight 2000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 7000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 8000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 9000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight Explorer",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A local attacker with low privileges on the Windows system where the \nsoftware is installed can exploit this vulnerability to corrupt \nsensitive data. A data folder is created with very weak privileges, \nallowing any user logged into the Windows system to modify its content."
}
],
"value": "A local attacker with low privileges on the Windows system where the \nsoftware is installed can exploit this vulnerability to corrupt \nsensitive data. A data folder is created with very weak privileges, \nallowing any user logged into the Windows system to modify its content."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-18T21:10:03.344Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-06"
}
],
"source": {
"advisory": "ICSA-25-261-06",
"discovery": "EXTERNAL"
},
"title": "Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Default Permissions",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras.\n\n\u003cbr\u003e"
}
],
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-53947",
"datePublished": "2025-09-18T21:10:03.344Z",
"dateReserved": "2025-08-06T16:32:41.276Z",
"dateUpdated": "2025-09-19T12:10:31.664Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-47698 (GCVE-0-2025-47698)
Vulnerability from cvelistv5 – Published: 2025-09-18 21:07 – Updated: 2025-09-19 13:01
VLAI?
Summary
An adjacent attacker without authentication can exploit this vulnerability to retrieve a set of user-privileged credentials. These credentials are present during the firmware upgrade procedure.
Severity ?
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cognex | In-Sight 2000 series |
Affected:
5.x , ≤ 6.5.1
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-47698",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-19T13:01:32.969885Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-19T13:01:51.935Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "In-Sight 2000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 7000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 8000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 9000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight Explorer",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA."
}
],
"datePublic": "2025-09-18T16:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn adjacent attacker without authentication can exploit this vulnerability to retrieve a set of user-privileged credentials. These credentials are present during the firmware upgrade procedure.\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "An adjacent attacker without authentication can exploit this vulnerability to retrieve a set of user-privileged credentials. These credentials are present during the firmware upgrade procedure."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-18T22:27:10.326Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-06"
}
],
"source": {
"discovery": "UNKNOWN"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCognex reports that In-Sight Explorer based vision systems are legacy products not intended for new applications. To reduce risk, asset owners are advised to switch to next generation In-Sight Vision Suite based vision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 series embedded cameras.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy products not intended for new applications. To reduce risk, asset owners are advised to switch to next generation In-Sight Vision Suite based vision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 series embedded cameras."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-47698",
"datePublished": "2025-09-18T21:07:39.648Z",
"dateReserved": "2025-08-06T16:32:41.259Z",
"dateUpdated": "2025-09-19T13:01:51.935Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-54754 (GCVE-0-2025-54754)
Vulnerability from cvelistv5 – Published: 2025-09-18 21:06 – Updated: 2025-09-19 13:04
VLAI?
Title
Cognex In-Sight Explorer and In-Sight Camera Firmware Use of Hard-coded Password
Summary
An attacker with adjacent access, without authentication, can exploit
this vulnerability to retrieve a hard-coded password embedded in
publicly available software. This password can then be used to decrypt
sensitive network traffic, affecting the Cognex device.
Severity ?
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cognex | In-Sight 2000 series |
Affected:
5.x , ≤ 6.5.1
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54754",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-19T13:03:56.638904Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-19T13:04:14.180Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "In-Sight 2000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 7000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 8000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight 9000 series",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "In-Sight Explorer",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "6.5.1",
"status": "affected",
"version": "5.x",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An attacker with adjacent access, without authentication, can exploit \nthis vulnerability to retrieve a hard-coded password embedded in \npublicly available software. This password can then be used to decrypt \nsensitive network traffic, affecting the Cognex device."
}
],
"value": "An attacker with adjacent access, without authentication, can exploit \nthis vulnerability to retrieve a hard-coded password embedded in \npublicly available software. This password can then be used to decrypt \nsensitive network traffic, affecting the Cognex device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "CWE-259",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-18T21:06:15.053Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-06"
}
],
"source": {
"advisory": "ICSA-25-261-06",
"discovery": "EXTERNAL"
},
"title": "Cognex In-Sight Explorer and In-Sight Camera Firmware Use of Hard-coded Password",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras.\n\n\u003cbr\u003e"
}
],
"value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-54754",
"datePublished": "2025-09-18T21:06:15.053Z",
"dateReserved": "2025-08-06T16:32:41.245Z",
"dateUpdated": "2025-09-19T13:04:14.180Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-1522 (GCVE-0-2022-1522)
Vulnerability from cvelistv5 – Published: 2022-09-06 22:19 – Updated: 2025-04-16 16:10
VLAI?
Title
Cognex 3D-A1000 Dimensioning System Improper Output Neutralization for Logs
Summary
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-117: Improper Output Neutralization for Logs, which allows an attacker to create false logs that show the password as having been changed when it is not, complicating forensics.
Severity ?
5.3 (Medium)
CWE
- CWE-117 - Improper Output Neutralization for Logs
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Cognex | 3D-A1000 Dimensioning System |
Affected:
all , ≤ 1.0.3 (3354)
(custom)
|
Credits
Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:10:02.959Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-1522",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:54:24.791900Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:10:35.734Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "3D-A1000 Dimensioning System",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "1.0.3 (3354)",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-117: Improper Output Neutralization for Logs, which allows an attacker to create false logs that show the password as having been changed when it is not, complicating forensics."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-117",
"description": "CWE-117 Improper Output Neutralization for Logs",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-06T22:19:13.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Cognex 3D-A1000 Dimensioning System Improper Output Neutralization for Logs",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2022-1522",
"STATE": "PUBLIC",
"TITLE": "Cognex 3D-A1000 Dimensioning System Improper Output Neutralization for Logs"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "3D-A1000 Dimensioning System",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "all",
"version_value": "1.0.3 (3354)"
}
]
}
}
]
},
"vendor_name": "Cognex"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-117: Improper Output Neutralization for Logs, which allows an attacker to create false logs that show the password as having been changed when it is not, complicating forensics."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-117 Improper Output Neutralization for Logs"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-1522",
"datePublished": "2022-09-06T22:19:13.000Z",
"dateReserved": "2022-04-28T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:10:35.734Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-1525 (GCVE-0-2022-1525)
Vulnerability from cvelistv5 – Published: 2022-09-06 22:19 – Updated: 2025-04-16 16:10
VLAI?
Title
Cognex 3D-A1000 Dimensioning System Client-Side Enforcement of Server-Side Security
Summary
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-602: Client-Side Enforcement of Server-Side Security, which could allow attackers to bypass web access controls by inspecting and modifying the source code of password protected web elements.
Severity ?
9.1 (Critical)
CWE
- CWE-602 - Client-Side Enforcement of Server-Side Security
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Cognex | 3D-A1000 Dimensioning System |
Affected:
all , ≤ 1.0.3 (3354)
(custom)
|
Credits
Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:10:03.434Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-1525",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:53:34.011709Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:10:27.445Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "3D-A1000 Dimensioning System",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "1.0.3 (3354)",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-602: Client-Side Enforcement of Server-Side Security, which could allow attackers to bypass web access controls by inspecting and modifying the source code of password protected web elements."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-602",
"description": "CWE-602 Client-Side Enforcement of Server-Side Security",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-06T22:19:13.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Cognex 3D-A1000 Dimensioning System Client-Side Enforcement of Server-Side Security",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2022-1525",
"STATE": "PUBLIC",
"TITLE": "Cognex 3D-A1000 Dimensioning System Client-Side Enforcement of Server-Side Security"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "3D-A1000 Dimensioning System",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "all",
"version_value": "1.0.3 (3354)"
}
]
}
}
]
},
"vendor_name": "Cognex"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-602: Client-Side Enforcement of Server-Side Security, which could allow attackers to bypass web access controls by inspecting and modifying the source code of password protected web elements."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-602 Client-Side Enforcement of Server-Side Security"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-1525",
"datePublished": "2022-09-06T22:19:13.000Z",
"dateReserved": "2022-04-28T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:10:27.445Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-1368 (GCVE-0-2022-1368)
Vulnerability from cvelistv5 – Published: 2022-09-06 22:19 – Updated: 2025-04-16 16:10
VLAI?
Title
Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function
Summary
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.
Severity ?
9.8 (Critical)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Cognex | 3D-A1000 Dimensioning System |
Affected:
all , ≤ 1.0.3 (3354)
(custom)
|
Credits
Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:03:05.837Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-1368",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:53:38.376179Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:10:43.133Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "3D-A1000 Dimensioning System",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "1.0.3 (3354)",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-06T22:19:13.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2022-1368",
"STATE": "PUBLIC",
"TITLE": "Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "3D-A1000 Dimensioning System",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "all",
"version_value": "1.0.3 (3354)"
}
]
}
}
]
},
"vendor_name": "Cognex"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-1368",
"datePublished": "2022-09-06T22:19:13.000Z",
"dateReserved": "2022-04-14T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:10:43.133Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32935 (GCVE-0-2021-32935)
Vulnerability from cvelistv5 – Published: 2022-05-23 18:42 – Updated: 2025-04-16 17:53
VLAI?
Title
Cognex In-Sight OPC Server - Deserialization of Untrusted Data
Summary
The affected Cognex product, the In-Sight OPC Server versions v5.7.4 (96) and prior, deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation.
Severity ?
8.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Cognex | In-Sight OPC Server |
Affected:
All , ≤ v5.7.4 (96)
(custom)
|
Credits
Amir Preminger of Claroty reported this vulnerability to CISA.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:33:56.094Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-224-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-32935",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:29:00.697855Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:53:44.261Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "In-Sight OPC Server",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "v5.7.4 (96)",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Amir Preminger of Claroty reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "The affected Cognex product, the In-Sight OPC Server versions v5.7.4 (96) and prior, deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-23T18:42:20.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-224-01"
}
],
"source": {
"advisory": "ICSA-21-224-01",
"discovery": "UNKNOWN"
},
"title": "Cognex In-Sight OPC Server - Deserialization of Untrusted Data",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-32935",
"STATE": "PUBLIC",
"TITLE": "Cognex In-Sight OPC Server - Deserialization of Untrusted Data"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "In-Sight OPC Server",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "v5.7.4 (96)"
}
]
}
}
]
},
"vendor_name": "Cognex"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Amir Preminger of Claroty reported this vulnerability to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected Cognex product, the In-Sight OPC Server versions v5.7.4 (96) and prior, deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-502 Deserialization of Untrusted Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-224-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-224-01"
}
]
},
"source": {
"advisory": "ICSA-21-224-01",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-32935",
"datePublished": "2022-05-23T18:42:20.000Z",
"dateReserved": "2021-05-13T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:53:44.261Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}