CVE-2022-1368 (GCVE-0-2022-1368)
Vulnerability from cvelistv5 – Published: 2022-09-06 22:19 – Updated: 2025-04-16 16:10
VLAI?
Title
Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function
Summary
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.
Severity ?
9.8 (Critical)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Cognex | 3D-A1000 Dimensioning System |
Affected:
all , ≤ 1.0.3 (3354)
(custom)
|
Credits
Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:03:05.837Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-1368",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:53:38.376179Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:10:43.133Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "3D-A1000 Dimensioning System",
"vendor": "Cognex",
"versions": [
{
"lessThanOrEqual": "1.0.3 (3354)",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-06T22:19:13.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2022-1368",
"STATE": "PUBLIC",
"TITLE": "Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "3D-A1000 Dimensioning System",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "all",
"version_value": "1.0.3 (3354)"
}
]
}
}
]
},
"vendor_name": "Cognex"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-1368",
"datePublished": "2022-09-06T22:19:13.000Z",
"dateReserved": "2022-04-14T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:10:43.133Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:cognex:3d-a1000_dimensioning_system_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"1.0.3\\\\(3354\\\\)\", \"matchCriteriaId\": \"BE25BB24-A1BE-4904-935B-61E84CAAFD81\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cognex:3d-a1000_dimensioning_system:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"01F624C6-079A-40BB-BA07-3441A6934850\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.\"}, {\"lang\": \"es\", \"value\": \"Cognex 3D-A1000 Dimensioning System en versi\\u00f3n de firmware 1.0.3 (3354) y anteriores, es vulnerable a CWE-306: Una Falta de Autentificaci\\u00f3n para la Funci\\u00f3n Cr\\u00edtica, que permite que usuarios no autorizados cambien la contrase\\u00f1a de la cuenta del operador por medio de comandos del servidor web mediante la monitorizaci\\u00f3n de las comunicaciones del socket web desde una sesi\\u00f3n no autenticada. Esto podr\\u00eda permitir a un atacante escalar privilegios hasta igualar los de la cuenta comprometida.\\n\"}]",
"id": "CVE-2022-1368",
"lastModified": "2024-11-21T06:40:35.250",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}]}",
"published": "2022-09-06T23:15:08.240",
"references": "[{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-1368\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2022-09-06T23:15:08.240\",\"lastModified\":\"2024-11-21T06:40:35.250\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.\"},{\"lang\":\"es\",\"value\":\"Cognex 3D-A1000 Dimensioning System en versi\u00f3n de firmware 1.0.3 (3354) y anteriores, es vulnerable a CWE-306: Una Falta de Autentificaci\u00f3n para la Funci\u00f3n Cr\u00edtica, que permite que usuarios no autorizados cambien la contrase\u00f1a de la cuenta del operador por medio de comandos del servidor web mediante la monitorizaci\u00f3n de las comunicaciones del socket web desde una sesi\u00f3n no autenticada. Esto podr\u00eda permitir a un atacante escalar privilegios hasta igualar los de la cuenta comprometida.\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cognex:3d-a1000_dimensioning_system_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.0.3\\\\(3354\\\\)\",\"matchCriteriaId\":\"BE25BB24-A1BE-4904-935B-61E84CAAFD81\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cognex:3d-a1000_dimensioning_system:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"01F624C6-079A-40BB-BA07-3441A6934850\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T00:03:05.837Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-1368\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-16T15:53:38.376179Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-16T15:53:41.388Z\"}}], \"cna\": {\"title\": \"Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"value\": \"Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA.\"}], \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"Cognex\", \"product\": \"3D-A1000 Dimensioning System\", \"versions\": [{\"status\": \"affected\", \"version\": \"all\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.0.3 (3354)\"}]}], \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03\", \"tags\": [\"x_refsource_MISC\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-306\", \"description\": \"CWE-306 Missing Authentication for Critical Function\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2022-09-06T22:19:13.000Z\"}, \"x_legacyV4Record\": {\"credit\": [{\"lang\": \"eng\", \"value\": \"Tri Quach, Shanil Prasad, Brandon Park, and Nishith Sinha reported these vulnerabilities to CISA.\"}], \"impact\": {\"cvss\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, \"source\": {\"discovery\": \"UNKNOWN\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_name\": \"all\", \"version_value\": \"1.0.3 (3354)\", \"version_affected\": \"\u003c=\"}]}, \"product_name\": \"3D-A1000 Dimensioning System\"}]}, \"vendor_name\": \"Cognex\"}]}}, \"data_type\": \"CVE\", \"generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"references\": {\"reference_data\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03\", \"name\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-306 Missing Authentication for Critical Function\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2022-1368\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function\", \"ASSIGNER\": \"ics-cert@hq.dhs.gov\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-1368\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-16T16:10:43.133Z\", \"dateReserved\": \"2022-04-14T00:00:00.000Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2022-09-06T22:19:13.000Z\", \"assignerShortName\": \"icscert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…