CVE-2023-1709 (GCVE-0-2023-1709)
Vulnerability from cvelistv5 – Published: 2023-06-07 20:36 – Updated: 2025-01-06 19:59
VLAI?
Summary
Datalogics Library APDFLThe v18.0.4PlusP1e and prior contains a stack-based buffer overflow due to documents containing corrupted fonts, which could allow an attack that causes an unhandled crash during the rendering process.
Severity ?
7.8 (High)
5.5 (Medium)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < 14.2.0.2
(custom)
|
||||||||||||
|
||||||||||||||
Credits
Michael Heinzl reported this vulnerability to Siemens.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:57:25.034Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-11"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-629917.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-164-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-1709",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T19:59:18.928582Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T19:59:28.270Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "JT2Go",
"vendor": "Siemens ",
"versions": [
{
"lessThan": "14.2.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization",
"vendor": "Siemens ",
"versions": [
{
"lessThan": "13.2.0.13",
"status": "affected",
"version": "13.2",
"versionType": "custom"
},
{
"lessThan": "13.3.0.9",
"status": "affected",
"version": "13.3",
"versionType": "custom"
},
{
"lessThan": "14.0.0.5",
"status": "affected",
"version": "14.0",
"versionType": "custom"
},
{
"lessThan": "14.1.0.7",
"status": "affected",
"version": "14.1",
"versionType": "custom"
},
{
"lessThan": "14.2.0.2",
"status": "affected",
"version": "14.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Library APDFL",
"vendor": "Datalogics",
"versions": [
{
"lessThanOrEqual": "v18.0.4PlusP1e",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Michael Heinzl reported this vulnerability to Siemens. "
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nDatalogics Library APDFLThe v18.0.4PlusP1e and prior contains a stack-based buffer overflow due to documents containing corrupted fonts, which could allow an attack that causes an unhandled crash during the rendering process.\n\n \n\n"
}
],
"value": "\nDatalogics Library APDFLThe v18.0.4PlusP1e and prior contains a stack-based buffer overflow due to documents containing corrupted fonts, which could allow an attack that causes an unhandled crash during the rendering process.\n\n \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-14T20:17:02.964Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-11"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-629917.html"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-164-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\u003cdiv\u003eSiemens has released updates for the affected products and recommends updating to the latest versions:\u003c/div\u003e\u003cul\u003e\u003cli\u003eJT2Go: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\"\u003eUpdate to V14.2.0.2\u003c/a\u003e or later version\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V13.2: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V13.2.0.13\u003c/a\u003e\u0026nbsp; or later version \u003c/li\u003e\u003cli\u003eTeamcenter Visualization V13.3: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V13.3.0.9\u003c/a\u003e\u0026nbsp; or later version \u003c/li\u003e\u003cli\u003eTeamcenter Visualization V14.0: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.0.0.5\u003c/a\u003e\u0026nbsp; or later version \u003c/li\u003e\u003cli\u003eTeamcenter Visualization V14.1: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.1.0.7\u003c/a\u003e\u0026nbsp; or later version \u003c/li\u003e\u003cli\u003eTeamcenter Visualization V14.2: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.2.0.2\u003c/a\u003e\u0026nbsp; or later version \n\n\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Siemens has released updates for the affected products and recommends updating to the latest versions:\n\n * JT2Go: Update to V14.2.0.2 https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html or later version\n * Teamcenter Visualization V13.2: Update to V13.2.0.13 https://support.sw.siemens.com/ \u00a0 or later version \n * Teamcenter Visualization V13.3: Update to V13.3.0.9 https://support.sw.siemens.com/ \u00a0 or later version \n * Teamcenter Visualization V14.0: Update to V14.0.0.5 https://support.sw.siemens.com/ \u00a0 or later version \n * Teamcenter Visualization V14.1: Update to V14.1.0.7 https://support.sw.siemens.com/ \u00a0 or later version \n * Teamcenter Visualization V14.2: Update to V14.2.0.2 https://support.sw.siemens.com/ \u00a0 or later version \n\n\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Datalogics Library APDFL Stack-based Buffer Overflow",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\u003cp\u003eSiemens has identified the following specific workarounds and mitigations that users can apply to reduce risks: \u003c/p\u003e\n\u003cul\u003e\u003cli\u003eAvoid opening untrusted files in JT2Go and Teamcenter Visualization \u003c/li\u003e\n\u003c/ul\u003e\u003cp\u003eAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\"\u003eoperational guidelines for industrial security\u003c/a\u003e,\n and to follow the recommendations in the product manuals. Additional \ninformation on industrial security by Siemens can be found at the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eSiemens Industrial Security web page\u003c/a\u003e. \n\u003c/p\u003e\u003cp\u003eFor further inquiries on security vulnerabilities in Siemens products and solutions, users should contact the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\"\u003eSiemens ProductCERT\u003c/a\u003e.\u003c/p\u003e"
}
],
"value": "Siemens has identified the following specific workarounds and mitigations that users can apply to reduce risks: \n\n\n * Avoid opening untrusted files in JT2Go and Teamcenter Visualization \n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security ,\n and to follow the recommendations in the product manuals. Additional \ninformation on industrial security by Siemens can be found at the Siemens Industrial Security web page https://www.siemens.com/industrialsecurity . \n\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, users should contact the Siemens ProductCERT https://www.siemens.com/cert/advisories .\n\n"
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\u003cp\u003eDatalogics recommends users to update to APDFL v18.0.4PlusP1g. \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.datalogics.com/datalogics-contact-us\"\u003eContact Datalogics\u003c/a\u003e\u0026nbsp;for more information on obtaining this update.\u003c/p\u003e\u003cp\u003eFor more information, refer to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dev.datalogics.com/adobe-pdf-library/release-notes-adobe-pdf-library-v-18/\"\u003eDatalogic\u2019s release notes\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "Datalogics recommends users to update to APDFL v18.0.4PlusP1g. Contact Datalogics https://www.datalogics.com/datalogics-contact-us \u00a0for more information on obtaining this update.\n\nFor more information, refer to Datalogic\u2019s release notes https://dev.datalogics.com/adobe-pdf-library/release-notes-adobe-pdf-library-v-18/ .\n\n\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-1709",
"datePublished": "2023-06-07T20:36:05.055Z",
"dateReserved": "2023-03-29T22:59:38.901Z",
"dateUpdated": "2025-01-06T19:59:28.270Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}