Search criteria

4 vulnerabilities by HIKSEMI

CVE-2026-22626 (GCVE-0-2026-22626)

Vulnerability from cvelistv5 – Published: 2026-01-30 11:03 – Updated: 2026-02-27 14:37
VLAI?
Summary
Due to insufficient input parameter validation on the interface, authenticated users of certain HIKSEMI NAS products can cause abnormal device behavior by crafting specific messages.
CWE
  • CWE-233 - Improper Handling of Parameters
Assigner
Impacted products
Vendor Product Version
HIKSEMI HS-AFS-S1H1 Affected: V5.10.10_Build_251126
Create a notification for this product.
Credits
Jincheng Wang
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-22626",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-30T12:40:22.043403Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-233",
                "description": "CWE-233 Improper Handling of Parameters",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-27T14:37:37.094Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HS-AFS-S1H1",
          "vendor": "HIKSEMI",
          "versions": [
            {
              "status": "affected",
              "version": "V5.10.10_Build_251126"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jincheng Wang"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Due to insufficient input parameter validation on the interface, authenticated users of certain HIKSEMI NAS products can cause abnormal device behavior by crafting specific messages."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-30T11:03:29.709Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hiksemitech.com/en/hiksemi/support/security-advisory.html"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-22626",
    "datePublished": "2026-01-30T11:03:29.709Z",
    "dateReserved": "2026-01-08T05:37:27.997Z",
    "dateUpdated": "2026-02-27T14:37:37.094Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-22625 (GCVE-0-2026-22625)

Vulnerability from cvelistv5 – Published: 2026-01-30 11:03 – Updated: 2026-02-27 14:42
VLAI?
Summary
Improper handling of filenames in certain HIKSEMI NAS products may lead to the exposure of sensitive system files.
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
Impacted products
Vendor Product Version
HIKSEMI HS-AFS-S1H1 Affected: V5.10.10_Build_251126
Create a notification for this product.
Credits
Jincheng Wang
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-22625",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-30T12:41:35.848702Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-22",
                "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-27T14:42:08.422Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HS-AFS-S1H1",
          "vendor": "HIKSEMI",
          "versions": [
            {
              "status": "affected",
              "version": "V5.10.10_Build_251126"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jincheng Wang"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper handling of filenames in certain HIKSEMI NAS products may lead to the exposure of sensitive system files."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-30T11:03:14.801Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hiksemitech.com/en/hiksemi/support/security-advisory.html"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-22625",
    "datePublished": "2026-01-30T11:03:14.801Z",
    "dateReserved": "2026-01-08T05:37:27.997Z",
    "dateUpdated": "2026-02-27T14:42:08.422Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-22624 (GCVE-0-2026-22624)

Vulnerability from cvelistv5 – Published: 2026-01-30 11:03 – Updated: 2026-02-27 14:44
VLAI?
Summary
Due to inadequate access control, authenticated users of certain HIKSEMI NAS products can manipulate other users' file resources without proper authorization.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
Impacted products
Vendor Product Version
HIKSEMI HS-AFS-S1H1 Affected: V5.10.10_Build_251126
Create a notification for this product.
Credits
Jincheng Wang
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-22624",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-30T12:43:48.203961Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-863",
                "description": "CWE-863 Incorrect Authorization",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-27T14:44:15.585Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HS-AFS-S1H1",
          "vendor": "HIKSEMI",
          "versions": [
            {
              "status": "affected",
              "version": "V5.10.10_Build_251126"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jincheng Wang"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Due to inadequate access control, authenticated users of certain HIKSEMI NAS products can manipulate other users\u0027 file resources without proper authorization."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-30T11:03:02.811Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hiksemitech.com/en/hiksemi/support/security-advisory.html"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-22624",
    "datePublished": "2026-01-30T11:03:02.811Z",
    "dateReserved": "2026-01-08T05:37:27.997Z",
    "dateUpdated": "2026-02-27T14:44:15.585Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-22623 (GCVE-0-2026-22623)

Vulnerability from cvelistv5 – Published: 2026-01-30 11:02 – Updated: 2026-02-27 14:45
VLAI?
Summary
Due to insufficient input parameter validation on the interface, authenticated users of certain HIKSEMI NAS products can execute arbitrary commands on the device by crafting specific messages.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
Impacted products
Vendor Product Version
HIKSEMI HS-AFS-S1H1 Affected: V5.10.10_Build_251126
Create a notification for this product.
Credits
Jincheng Wang
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-22623",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-30T12:44:59.407089Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-27T14:45:19.674Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HS-AFS-S1H1",
          "vendor": "HIKSEMI",
          "versions": [
            {
              "status": "affected",
              "version": "V5.10.10_Build_251126"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jincheng Wang"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Due to insufficient input parameter validation on the interface, authenticated users of certain HIKSEMI NAS products can execute arbitrary commands on the device by crafting specific messages."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-30T11:02:26.539Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hiksemitech.com/en/hiksemi/support/security-advisory.html"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-22623",
    "datePublished": "2026-01-30T11:02:26.539Z",
    "dateReserved": "2026-01-08T05:37:27.997Z",
    "dateUpdated": "2026-02-27T14:45:19.674Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}