CVE-2023-50233 (GCVE-0-2023-50233)
Vulnerability from cvelistv5 – Published: 2024-05-03 02:14 – Updated: 2024-08-02 22:09
VLAI?
Summary
Inductive Automation Ignition getJavaExecutable Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server.
The specific flaw exists within the getJavaExecutable method. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22029.
Severity ?
8.8 (High)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.31
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:8.1.31:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"status": "affected",
"version": "8.1.31"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-50233",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-19T14:09:00.610715Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-19T21:03:14.575Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:09:49.895Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-24-185",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-185/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.31"
}
]
}
],
"dateAssigned": "2023-12-05T13:37:59.749-06:00",
"datePublic": "2024-02-21T13:14:57.983-06:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition getJavaExecutable Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server.\n\nThe specific flaw exists within the getJavaExecutable method. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22029."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T02:14:49.645Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-185",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-185/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"source": {
"lang": "en",
"value": "Piotr Bazydlo (@chudypb) of Trend Micro Zero Day Initiative"
},
"title": "Inductive Automation Ignition getJavaExecutable Directory Traversal Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-50233",
"datePublished": "2024-05-03T02:14:49.645Z",
"dateReserved": "2023-12-05T16:15:17.545Z",
"dateUpdated": "2024-08-02T22:09:49.895Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-50232 (GCVE-0-2023-50232)
Vulnerability from cvelistv5 – Published: 2024-05-03 02:14 – Updated: 2024-08-02 22:09
VLAI?
Summary
Inductive Automation Ignition getParams Argument Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server.
The specific flaw exists within the getParams method. The issue results from the lack of proper validation of a user-supplied string before using it to prepare an argument for a system call. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22028.
Severity ?
8.8 (High)
CWE
- CWE-88 - Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.31
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:8.1.31:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"lessThan": "8.1.35",
"status": "affected",
"version": "8.1.31",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-50232",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-14T19:21:19.849756Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-14T19:25:30.871Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:09:49.865Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-24-184",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-184/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.31"
}
]
}
],
"dateAssigned": "2023-12-05T13:37:59.744-06:00",
"datePublic": "2024-02-21T13:14:52.766-06:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition getParams Argument Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server.\n\nThe specific flaw exists within the getParams method. The issue results from the lack of proper validation of a user-supplied string before using it to prepare an argument for a system call. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22028."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-88",
"description": "CWE-88: Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T02:14:48.881Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-184",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-184/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"source": {
"lang": "en",
"value": "Piotr Bazydlo (@chudypb) of Trend Micro Zero Day Initiative"
},
"title": "Inductive Automation Ignition getParams Argument Injection Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-50232",
"datePublished": "2024-05-03T02:14:48.881Z",
"dateReserved": "2023-12-05T16:15:17.545Z",
"dateUpdated": "2024-08-02T22:09:49.865Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-50223 (GCVE-0-2023-50223)
Vulnerability from cvelistv5 – Published: 2024-05-03 02:14 – Updated: 2024-08-02 22:09
VLAI?
Summary
Inductive Automation Ignition ExtendedDocumentCodec Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.
The specific flaw exists within the ExtendedDocumentCodec class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-22127.
Severity ?
8.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
6.4.1.207
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"status": "affected",
"version": "6.4.1.207"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-50223",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-17T16:48:13.947162Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-17T17:05:08.998Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:09:49.796Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-24-018",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-018/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "6.4.1.207"
}
]
}
],
"dateAssigned": "2023-12-05T13:37:59.691-06:00",
"datePublic": "2024-01-05T09:00:27.138-06:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition ExtendedDocumentCodec Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the ExtendedDocumentCodec class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-22127."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T02:14:42.233Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-018",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-018/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"source": {
"lang": "en",
"value": "Andy Niu of Trend Micro Security Research"
},
"title": "Inductive Automation Ignition ExtendedDocumentCodec Deserialization of Untrusted Data Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-50223",
"datePublished": "2024-05-03T02:14:42.233Z",
"dateReserved": "2023-12-05T16:15:17.542Z",
"dateUpdated": "2024-08-02T22:09:49.796Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-50222 (GCVE-0-2023-50222)
Vulnerability from cvelistv5 – Published: 2024-05-03 02:14 – Updated: 2024-08-02 22:09
VLAI?
Summary
Inductive Automation Ignition ResponseParser Notification Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server.
The specific flaw exists within the ResponseParser method. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22067.
Severity ?
8.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.31
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"status": "affected",
"version": "8.1.31"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-50222",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-03T21:03:47.740884Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:17:59.944Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:09:49.870Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-24-017",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-017/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.31"
}
]
}
],
"dateAssigned": "2023-12-05T13:37:59.686-06:00",
"datePublic": "2024-01-05T09:00:22.033-06:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition ResponseParser Notification Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server.\n\nThe specific flaw exists within the ResponseParser method. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22067."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T02:14:41.474Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-017",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-017/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"source": {
"lang": "en",
"value": "Piotr Bazydlo (@chudypb) of Trend Micro Zero Day Initiative"
},
"title": "Inductive Automation Ignition ResponseParser Notification Deserialization of Untrusted Data Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-50222",
"datePublished": "2024-05-03T02:14:41.474Z",
"dateReserved": "2023-12-05T16:15:17.542Z",
"dateUpdated": "2024-08-02T22:09:49.870Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-50221 (GCVE-0-2023-50221)
Vulnerability from cvelistv5 – Published: 2024-05-03 02:14 – Updated: 2024-08-02 22:09
VLAI?
Summary
Inductive Automation Ignition ResponseParser SerializedResponse Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server.
The specific flaw exists within the ResponseParser method. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-21926.
Severity ?
8.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.31
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"status": "affected",
"version": "8.1.31"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-50221",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-17T19:58:04.180966Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-17T20:01:39.250Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:09:49.681Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-24-016",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-016/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.31"
}
]
}
],
"dateAssigned": "2023-12-05T13:37:59.678-06:00",
"datePublic": "2024-01-05T09:00:17.168-06:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition ResponseParser SerializedResponse Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server.\n\nThe specific flaw exists within the ResponseParser method. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-21926."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T02:14:40.701Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-016",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-016/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"source": {
"lang": "en",
"value": "Nguyen Quoc Viet (Petrus Viet) of VNG Security Researcher"
},
"title": "Inductive Automation Ignition ResponseParser SerializedResponse Deserialization of Untrusted Data Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-50221",
"datePublished": "2024-05-03T02:14:40.701Z",
"dateReserved": "2023-12-05T16:15:17.542Z",
"dateUpdated": "2024-08-02T22:09:49.681Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-50220 (GCVE-0-2023-50220)
Vulnerability from cvelistv5 – Published: 2024-05-03 02:14 – Updated: 2024-08-02 22:09
VLAI?
Summary
Inductive Automation Ignition Base64Element Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.
The specific flaw exists within the Base64Element class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-21801.
Severity ?
7.2 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.30
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:8.1.3:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"status": "affected",
"version": "8.1.30"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-50220",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-21T18:14:54.610553Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:17:50.778Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:09:49.876Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-24-015",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-015/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.30"
}
]
}
],
"dateAssigned": "2023-12-05T13:37:59.672-06:00",
"datePublic": "2024-01-05T09:00:11.022-06:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition Base64Element Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the Base64Element class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-21801."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T02:14:39.917Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-015",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-015/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"source": {
"lang": "en",
"value": "Nguyen Quoc Viet (Petrus Viet) of VNG Security Researcher"
},
"title": "Inductive Automation Ignition Base64Element Deserialization of Untrusted Data Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-50220",
"datePublished": "2024-05-03T02:14:39.917Z",
"dateReserved": "2023-12-05T16:15:17.542Z",
"dateUpdated": "2024-08-02T22:09:49.876Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-50219 (GCVE-0-2023-50219)
Vulnerability from cvelistv5 – Published: 2024-05-03 02:14 – Updated: 2024-08-02 22:09
VLAI?
Summary
Inductive Automation Ignition RunQuery Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.
The specific flaw exists within the RunQuery class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-21625.
Severity ?
8.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.30
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"status": "affected",
"version": "8.1.30"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-50219",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-03T20:15:14.831755Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:17:51.888Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:09:49.777Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-24-014",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-014/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.30"
}
]
}
],
"dateAssigned": "2023-12-05T13:37:59.667-06:00",
"datePublic": "2024-01-05T09:00:05.498-06:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition RunQuery Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the RunQuery class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-21625."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T02:14:39.147Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-014",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-014/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"source": {
"lang": "en",
"value": "Nguyen Quoc Viet (Petrus Viet) of VNG Security Researcher"
},
"title": "Inductive Automation Ignition RunQuery Deserialization of Untrusted Data Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-50219",
"datePublished": "2024-05-03T02:14:39.147Z",
"dateReserved": "2023-12-05T16:15:17.542Z",
"dateUpdated": "2024-08-02T22:09:49.777Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-50218 (GCVE-0-2023-50218)
Vulnerability from cvelistv5 – Published: 2024-05-03 02:14 – Updated: 2024-08-02 22:09
VLAI?
Summary
Inductive Automation Ignition ModuleInvoke Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.
The specific flaw exists within the ModuleInvoke class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-21624.
Severity ?
8.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.30
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:8.1.3:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"status": "affected",
"version": "8.1.3"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-50218",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-06T20:56:49.694175Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:17:58.468Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:09:49.786Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-1813",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1813/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.30"
}
]
}
],
"dateAssigned": "2023-12-05T13:37:59.662-06:00",
"datePublic": "2024-01-05T08:56:04.085-06:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition ModuleInvoke Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the ModuleInvoke class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-21624."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T02:14:38.394Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-1813",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1813/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://security.inductiveautomation.com/?tcuUid=fc4c4515-046d-4365-b688-693337449c5b"
}
],
"source": {
"lang": "en",
"value": "Nguyen Quoc Viet (Petrus Viet) of VNG Security Researcher"
},
"title": "Inductive Automation Ignition ModuleInvoke Deserialization of Untrusted Data Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-50218",
"datePublished": "2024-05-03T02:14:38.394Z",
"dateReserved": "2023-12-05T16:15:17.542Z",
"dateUpdated": "2024-08-02T22:09:49.786Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-39476 (GCVE-0-2023-39476)
Vulnerability from cvelistv5 – Published: 2024-05-03 02:10 – Updated: 2024-08-02 18:10
VLAI?
Summary
Inductive Automation Ignition JavaSerializationCodec Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the JavaSerializationCodec class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20291.
Severity ?
9.8 (Critical)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.25
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"lessThan": "8.1.35",
"status": "affected",
"version": "8.1.22",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-39476",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-05T17:03:23.809391Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T20:59:53.039Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:10:20.678Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-1046",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1046/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.25"
}
]
}
],
"dateAssigned": "2023-08-02T16:44:31.504-05:00",
"datePublic": "2023-08-08T09:49:12.720-05:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition JavaSerializationCodec Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the JavaSerializationCodec class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20291."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T02:10:42.122Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-1046",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1046/"
}
],
"source": {
"lang": "en",
"value": "Rocco Calvi (@TecR0c) and Steven Seeley (mr_me) of Incite Team"
},
"title": "Inductive Automation Ignition JavaSerializationCodec Deserialization of Untrusted Data Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-39476",
"datePublished": "2024-05-03T02:10:42.122Z",
"dateReserved": "2023-08-02T21:37:23.124Z",
"dateUpdated": "2024-08-02T18:10:20.678Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-39477 (GCVE-0-2023-39477)
Vulnerability from cvelistv5 – Published: 2024-05-03 02:10 – Updated: 2024-08-02 18:10
VLAI?
Summary
Inductive Automation Ignition ConditionRefresh Resource Exhaustion Denial-of-Service Vulnerability. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Inductive Automation Ignition. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the handling of OPC UA ConditionRefresh requests. By sending a large number of requests, an attacker can consume all available resources on the server. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-20499.
Severity ?
7.5 (High)
CWE
- CWE-400 - Uncontrolled Resource Consumption ('Resource Exhaustion')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.24
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:8.1.24:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"status": "affected",
"version": "8.1.24"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-39477",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-05T15:47:53.751712Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-05T17:35:42.447Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:10:20.832Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-1050",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1050/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://inductiveautomation.com/downloads/releasenotes/8.1.33"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.24"
}
]
}
],
"dateAssigned": "2023-08-02T16:44:31.510-05:00",
"datePublic": "2023-08-08T09:49:31.561-05:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition ConditionRefresh Resource Exhaustion Denial-of-Service Vulnerability. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Inductive Automation Ignition. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of OPC UA ConditionRefresh requests. By sending a large number of requests, an attacker can consume all available resources on the server. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-20499."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption (\u0027Resource Exhaustion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T02:10:42.854Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-1050",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1050/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://inductiveautomation.com/downloads/releasenotes/8.1.33"
}
],
"source": {
"lang": "en",
"value": "Claroty Research - Team82 - Uri Katz, Noam Moshe, Vera Vens, Sharon Brizinov"
},
"title": "Inductive Automation Ignition ConditionRefresh Resource Exhaustion Denial-of-Service Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-39477",
"datePublished": "2024-05-03T02:10:42.854Z",
"dateReserved": "2023-08-02T21:37:23.124Z",
"dateUpdated": "2024-08-02T18:10:20.832Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-39475 (GCVE-0-2023-39475)
Vulnerability from cvelistv5 – Published: 2024-05-03 02:10 – Updated: 2024-08-02 18:10
VLAI?
Summary
Inductive Automation Ignition ParameterVersionJavaSerializationCodec Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the ParameterVersionJavaSerializationCodec class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20290.
Severity ?
9.8 (Critical)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.25
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"lessThan": "8.1.35",
"status": "affected",
"version": "8.1.22",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-39475",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-05T17:00:31.612223Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T20:59:42.213Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:10:20.695Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-1047",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1047/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.25"
}
]
}
],
"dateAssigned": "2023-08-02T16:44:31.499-05:00",
"datePublic": "2023-08-08T09:49:17.670-05:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition ParameterVersionJavaSerializationCodec Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the ParameterVersionJavaSerializationCodec class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20290."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T02:10:41.406Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-1047",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1047/"
}
],
"source": {
"lang": "en",
"value": "Rocco Calvi (@TecR0c) and Steven Seeley (mr_me) of Incite Team"
},
"title": "Inductive Automation Ignition ParameterVersionJavaSerializationCodec Deserialization of Untrusted Data Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-39475",
"datePublished": "2024-05-03T02:10:41.406Z",
"dateReserved": "2023-08-02T21:37:23.124Z",
"dateUpdated": "2024-08-02T18:10:20.695Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-39474 (GCVE-0-2023-39474)
Vulnerability from cvelistv5 – Published: 2024-05-03 02:10 – Updated: 2024-09-18 18:29
VLAI?
Summary
Inductive Automation Ignition downloadLaunchClientJar Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server.
The specific flaw exists within the downloadLaunchClientJar function. The issue results from the lack of validating a remote JAR file prior to loading it. An attacker can leverage this vulnerability to execute code in the context of the current user.
. Was ZDI-CAN-19915.
Severity ?
CWE
- CWE-494 - Download of Code Without Integrity Check
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.24-RC / 1.1.24-RC
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-39474",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-17T19:35:35.328270Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-17T19:35:38.394Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:10:21.129Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-1049",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1049/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.24-RC / 1.1.24-RC"
}
]
}
],
"dateAssigned": "2023-08-02T16:44:31.493-05:00",
"datePublic": "2023-08-08T09:49:25.873-05:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition downloadLaunchClientJar Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must connect to a malicious server.\n\nThe specific flaw exists within the downloadLaunchClientJar function. The issue results from the lack of validating a remote JAR file prior to loading it. An attacker can leverage this vulnerability to execute code in the context of the current user.\n. Was ZDI-CAN-19915."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494: Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-18T18:29:37.407Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-1049",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1049/"
}
],
"source": {
"lang": "en",
"value": "Nguy\u1ec5n Ti\u1ebfn Giang (Jang) of STAR Labs SG Pte. Ltd."
},
"title": "Inductive Automation Ignition downloadLaunchClientJar Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-39474",
"datePublished": "2024-05-03T02:10:40.714Z",
"dateReserved": "2023-08-02T21:37:23.124Z",
"dateUpdated": "2024-09-18T18:29:37.407Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-39473 (GCVE-0-2023-39473)
Vulnerability from cvelistv5 – Published: 2024-05-03 02:10 – Updated: 2024-09-18 18:29
VLAI?
Summary
Inductive Automation Ignition AbstractGatewayFunction Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.
The specific flaw exists within the AbstractGatewayFunction class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM.
. Was ZDI-CAN-17587.
Severity ?
8.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
Inductive Automation Ignition 8.1.17 LTS
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"lessThan": "8.1.35",
"status": "affected",
"version": "8.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-39473",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-05T17:14:05.364540Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T21:00:08.201Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:10:20.890Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-1045",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1045/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "Inductive Automation Ignition 8.1.17 LTS"
}
]
}
],
"dateAssigned": "2023-08-02T16:44:31.488-05:00",
"datePublic": "2023-08-08T09:49:09.386-05:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition AbstractGatewayFunction Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the AbstractGatewayFunction class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM.\n. Was ZDI-CAN-17587."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-18T18:29:36.706Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-1045",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1045/"
}
],
"source": {
"lang": "en",
"value": "Piotr Bazydlo (@chudypb) of Trend Micro Zero Day Initiative"
},
"title": "Inductive Automation Ignition AbstractGatewayFunction Deserialization of Untrusted Data Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-39473",
"datePublished": "2024-05-03T02:10:39.937Z",
"dateReserved": "2023-08-02T21:37:23.124Z",
"dateUpdated": "2024-09-18T18:29:36.706Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-39472 (GCVE-0-2023-39472)
Vulnerability from cvelistv5 – Published: 2024-05-03 02:10 – Updated: 2024-08-02 18:10
VLAI?
Summary
Inductive Automation Ignition SimpleXMLReader XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.
The specific flaw exists within the SimpleXMLReader class. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the SYSTEM.
. Was ZDI-CAN-17571.
Severity ?
6.5 (Medium)
CWE
- CWE-611 - Improper Restriction of XML External Entity Reference ('XXE')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.17 LTS
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"status": "affected",
"version": "8.1.17 LTS"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-39472",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-10T18:22:51.863259Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:27:10.426Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:10:20.889Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-1048",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1048/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.17 LTS"
}
]
}
],
"dateAssigned": "2023-08-02T16:44:31.483-05:00",
"datePublic": "2023-08-08T09:49:22.244-05:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition SimpleXMLReader XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the SimpleXMLReader class. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the SYSTEM.\n. Was ZDI-CAN-17571."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-611",
"description": "CWE-611: Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-09T22:21:06.255Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-1048",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1048/"
}
],
"source": {
"lang": "en",
"value": "Piotr Bazydlo (@chudypb) of Trend Micro Zero Day Initiative"
},
"title": "Inductive Automation Ignition SimpleXMLReader XML External Entity Processing Information Disclosure Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-39472",
"datePublished": "2024-05-03T02:10:39.196Z",
"dateReserved": "2023-08-02T21:37:23.124Z",
"dateUpdated": "2024-08-02T18:10:20.889Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38124 (GCVE-0-2023-38124)
Vulnerability from cvelistv5 – Published: 2024-05-03 01:59 – Updated: 2024-08-02 17:30
VLAI?
Summary
Inductive Automation Ignition OPC UA Quick Client Task Scheduling Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.
The specific flaw exists within the Ignition Gateway server. The issue results from the exposure of a dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20541.
Severity ?
7.2 (High)
CWE
- CWE-749 - Exposed Dangerous Method or Function
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.24
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"status": "affected",
"version": "*"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-38124",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-16T17:29:25.520163Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:27:56.867Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:14.097Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-1015",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1015/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.24"
}
]
}
],
"dateAssigned": "2023-07-12T10:35:25.013-05:00",
"datePublic": "2023-08-01T09:08:05.021-05:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition OPC UA Quick Client Task Scheduling Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the Ignition Gateway server. The issue results from the exposure of a dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20541."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-749",
"description": "CWE-749: Exposed Dangerous Method or Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T01:59:20.496Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-1015",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1015/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security"
}
],
"source": {
"lang": "en",
"value": "20urdjk"
},
"title": "Inductive Automation Ignition OPC UA Quick Client Task Scheduling Exposed Dangerous Function Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-38124",
"datePublished": "2024-05-03T01:59:20.496Z",
"dateReserved": "2023-07-12T15:22:20.623Z",
"dateUpdated": "2024-08-02T17:30:14.097Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38123 (GCVE-0-2023-38123)
Vulnerability from cvelistv5 – Published: 2024-05-03 01:59 – Updated: 2024-08-02 17:30
VLAI?
Summary
Inductive Automation Ignition OPC UA Quick Client Missing Authentication for Critical Function Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
The specific flaw exists within the server configuration. The issue results from the lack of authentication prior to allowing access to password change functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-20540.
Severity ?
7.5 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.24
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"status": "affected",
"version": "8.1.24"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-38123",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-06T18:20:26.377240Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:28:11.909Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:14.068Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-1014",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1014/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.24"
}
]
}
],
"dateAssigned": "2023-07-12T10:35:25.007-05:00",
"datePublic": "2023-08-01T09:07:57.002-05:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition OPC UA Quick Client Missing Authentication for Critical Function Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the server configuration. The issue results from the lack of authentication prior to allowing access to password change functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-20540."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T01:59:19.765Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-1014",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1014/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security"
}
],
"source": {
"lang": "en",
"value": "20urdjk"
},
"title": "Inductive Automation Ignition OPC UA Quick Client Missing Authentication for Critical Function Authentication Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-38123",
"datePublished": "2024-05-03T01:59:19.765Z",
"dateReserved": "2023-07-12T15:22:20.623Z",
"dateUpdated": "2024-08-02T17:30:14.068Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38122 (GCVE-0-2023-38122)
Vulnerability from cvelistv5 – Published: 2024-05-03 01:59 – Updated: 2024-08-02 17:30
VLAI?
Summary
Inductive Automation Ignition OPC UA Quick Client Permissive Cross-domain Policy Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the configuration of the web server. The issue results from the lack of appropriate Content Security Policy headers. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of SYSTEM. Was ZDI-CAN-20539.
Severity ?
7.2 (High)
CWE
- CWE-942 - Permissive Cross-domain Policy with Untrusted Domains
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.24
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:8.1.24:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"status": "affected",
"version": "8.1.24"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-38122",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-06T18:46:07.517841Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-19T21:01:09.444Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:13.908Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-1013",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1013/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.24"
}
]
}
],
"dateAssigned": "2023-07-12T10:35:24.997-05:00",
"datePublic": "2023-08-01T09:07:46.401-05:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition OPC UA Quick Client Permissive Cross-domain Policy Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the configuration of the web server. The issue results from the lack of appropriate Content Security Policy headers. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of SYSTEM. Was ZDI-CAN-20539."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-942",
"description": "CWE-942: Permissive Cross-domain Policy with Untrusted Domains",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T01:59:19.031Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-1013",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1013/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security"
}
],
"source": {
"lang": "en",
"value": "20urdjk"
},
"title": "Inductive Automation Ignition OPC UA Quick Client Permissive Cross-domain Policy Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-38122",
"datePublished": "2024-05-03T01:59:19.031Z",
"dateReserved": "2023-07-12T15:22:20.623Z",
"dateUpdated": "2024-08-02T17:30:13.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38121 (GCVE-0-2023-38121)
Vulnerability from cvelistv5 – Published: 2024-05-03 01:59 – Updated: 2024-08-02 17:30
VLAI?
Summary
Inductive Automation Ignition OPC UA Quick Client Cross-Site Scripting Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
The specific flaw exists within the handling of the id parameter provided to the Inductive Automation Ignition web interface. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-20355.
Severity ?
8.3 (High)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.24
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:inductiveautomation:ignition:8.1.24:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ignition",
"vendor": "inductiveautomation",
"versions": [
{
"status": "affected",
"version": "8.1.24"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-38121",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-19T14:12:50.388895Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-29T20:29:46.334Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:14.050Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-1012",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1012/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.24"
}
]
}
],
"dateAssigned": "2023-07-12T10:35:24.991-05:00",
"datePublic": "2023-08-01T09:07:38.431-05:00",
"descriptions": [
{
"lang": "en",
"value": "Inductive Automation Ignition OPC UA Quick Client Cross-Site Scripting Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the handling of the id parameter provided to the Inductive Automation Ignition web interface. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-20355."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T01:59:18.329Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-1012",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1012/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security"
}
],
"source": {
"lang": "en",
"value": "20urdjk"
},
"title": "Inductive Automation Ignition OPC UA Quick Client Cross-Site Scripting Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-38121",
"datePublished": "2024-05-03T01:59:18.329Z",
"dateReserved": "2023-07-12T15:22:20.623Z",
"dateUpdated": "2024-08-02T17:30:14.050Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-1704 (GCVE-0-2022-1704)
Vulnerability from cvelistv5 – Published: 2022-08-05 15:25 – Updated: 2025-04-16 16:13
VLAI?
Summary
Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup.
Severity ?
7.6 (High)
CWE
- CWE-611 - Improper Restriction of XML External Entity Reference ('XXE')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1 , ≤ 8.1.7
(custom)
Affected: All , < 7.9.21 (custom) |
Credits
Keval Shah reported this vulnerability to CISA
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:10:03.916Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-1704",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:50:51.760136Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:13:45.512Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"lessThanOrEqual": "8.1.7",
"status": "affected",
"version": "8.1",
"versionType": "custom"
},
{
"lessThan": "7.9.21",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Keval Shah reported this vulnerability to CISA"
}
],
"datePublic": "2022-07-26T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-611",
"description": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-05T15:25:19.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Inductive Automation recommends users upgrade the Ignition software to the latest version:\n\nInductive Automation Ignition: Version 8.1.9 or later\nInductive Automation Ignition: Version 7.9.21 or later"
}
],
"source": {
"advisory": "ICSA-22-207-01",
"discovery": "EXTERNAL"
},
"title": "Inductive Automation Ignition",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-07-26T17:00:00.000Z",
"ID": "CVE-2022-1704",
"STATE": "PUBLIC",
"TITLE": "Inductive Automation Ignition"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ignition",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "8.1",
"version_value": "8.1.7"
},
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "7.9.21"
}
]
}
}
]
},
"vendor_name": "Inductive Automation"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Keval Shah reported this vulnerability to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Inductive Automation recommends users upgrade the Ignition software to the latest version:\n\nInductive Automation Ignition: Version 8.1.9 or later\nInductive Automation Ignition: Version 7.9.21 or later"
}
],
"source": {
"advisory": "ICSA-22-207-01",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-1704",
"datePublished": "2022-08-05T15:25:19.220Z",
"dateReserved": "2022-05-12T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:13:45.512Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35873 (GCVE-0-2022-35873)
Vulnerability from cvelistv5 – Published: 2022-07-25 18:17 – Updated: 2024-08-03 09:44
VLAI?
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of ZIP files. Crafted data in a ZIP file can cause the application to execute arbitrary Python scripts. The user interface fails to provide sufficient indication of the hazard. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16949.
Severity ?
7.8 (High)
CWE
- CWE-356 - Product UI does not Warn User of Unsafe Actions
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.15 (b2022030114)
|
Credits
20urdjk
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.090Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1020/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.15 (b2022030114)"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "20urdjk"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of ZIP files. Crafted data in a ZIP file can cause the application to execute arbitrary Python scripts. The user interface fails to provide sufficient indication of the hazard. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16949."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-356",
"description": "CWE-356: Product UI does not Warn User of Unsafe Actions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-25T18:17:01",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1020/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2022-35873",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ignition",
"version": {
"version_data": [
{
"version_value": "8.1.15 (b2022030114)"
}
]
}
}
]
},
"vendor_name": "Inductive Automation"
}
]
}
},
"credit": "20urdjk",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of ZIP files. Crafted data in a ZIP file can cause the application to execute arbitrary Python scripts. The user interface fails to provide sufficient indication of the hazard. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16949."
}
]
},
"impact": {
"cvss": {
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-356: Product UI does not Warn User of Unsafe Actions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities",
"refsource": "MISC",
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-22-1020/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1020/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2022-35873",
"datePublished": "2022-07-25T18:17:01",
"dateReserved": "2022-07-14T00:00:00",
"dateUpdated": "2024-08-03T09:44:22.090Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35872 (GCVE-0-2022-35872)
Vulnerability from cvelistv5 – Published: 2022-07-25 18:16 – Updated: 2024-08-03 09:44
VLAI?
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of ZIP files. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17115.
Severity ?
7.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.15 (b2022030114)
|
Credits
Piotr Bazydlo (@chudypb)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.147Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1019/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.15 (b2022030114)"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Piotr Bazydlo (@chudypb)"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of ZIP files. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17115."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-25T18:16:47",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1019/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2022-35872",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ignition",
"version": {
"version_data": [
{
"version_value": "8.1.15 (b2022030114)"
}
]
}
}
]
},
"vendor_name": "Inductive Automation"
}
]
}
},
"credit": "Piotr Bazydlo (@chudypb)",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of ZIP files. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17115."
}
]
},
"impact": {
"cvss": {
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-502: Deserialization of Untrusted Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities",
"refsource": "MISC",
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-22-1019/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1019/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2022-35872",
"datePublished": "2022-07-25T18:16:47",
"dateReserved": "2022-07-14T00:00:00",
"dateUpdated": "2024-08-03T09:44:22.147Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35871 (GCVE-0-2022-35871)
Vulnerability from cvelistv5 – Published: 2022-07-25 18:16 – Updated: 2024-08-03 09:44
VLAI?
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). Authentication is not required to exploit this vulnerability. The specific flaw exists within the authenticateAdSso method. The issue results from the lack of authentication prior to allowing the execution of python code. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17206.
Severity ?
8.1 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.15 (b2022030114)
|
Credits
Daan Keuper & Thijs Alkemade from Computest
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.103Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1018/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.15 (b2022030114)"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Daan Keuper \u0026 Thijs Alkemade from Computest"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). Authentication is not required to exploit this vulnerability. The specific flaw exists within the authenticateAdSso method. The issue results from the lack of authentication prior to allowing the execution of python code. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17206."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-25T18:16:39",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1018/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2022-35871",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ignition",
"version": {
"version_data": [
{
"version_value": "8.1.15 (b2022030114)"
}
]
}
}
]
},
"vendor_name": "Inductive Automation"
}
]
}
},
"credit": "Daan Keuper \u0026 Thijs Alkemade from Computest",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). Authentication is not required to exploit this vulnerability. The specific flaw exists within the authenticateAdSso method. The issue results from the lack of authentication prior to allowing the execution of python code. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17206."
}
]
},
"impact": {
"cvss": {
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities",
"refsource": "MISC",
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-22-1018/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1018/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2022-35871",
"datePublished": "2022-07-25T18:16:39",
"dateReserved": "2022-07-14T00:00:00",
"dateUpdated": "2024-08-03T09:44:22.103Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35870 (GCVE-0-2022-35870)
Vulnerability from cvelistv5 – Published: 2022-07-25 18:16 – Updated: 2024-08-03 09:44
VLAI?
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within com.inductiveautomation.metro.impl. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17265.
Severity ?
8.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.15 (b2022030114)
|
Credits
@_s_n_t of @pentestltd
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.285Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1017/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.15 (b2022030114)"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "@_s_n_t of @pentestltd"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within com.inductiveautomation.metro.impl. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17265."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-25T18:16:35",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1017/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2022-35870",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ignition",
"version": {
"version_data": [
{
"version_value": "8.1.15 (b2022030114)"
}
]
}
}
]
},
"vendor_name": "Inductive Automation"
}
]
}
},
"credit": "@_s_n_t of @pentestltd",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within com.inductiveautomation.metro.impl. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17265."
}
]
},
"impact": {
"cvss": {
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-502: Deserialization of Untrusted Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities",
"refsource": "MISC",
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-22-1017/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1017/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2022-35870",
"datePublished": "2022-07-25T18:16:35",
"dateReserved": "2022-07-14T00:00:00",
"dateUpdated": "2024-08-03T09:44:22.285Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35869 (GCVE-0-2022-35869)
Vulnerability from cvelistv5 – Published: 2022-07-25 18:16 – Updated: 2024-08-03 09:44
VLAI?
Summary
This vulnerability allows remote attackers to bypass authentication on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). Authentication is not required to exploit this vulnerability. The specific flaw exists within com.inductiveautomation.ignition.gateway.web.pages. The issue results from the lack of proper authentication prior to access to functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-17211.
Severity ?
7.5 (High)
CWE
- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
8.1.15 (b2022030114)
|
Credits
@_s_n_t of @pentestltd
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.094Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1016/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "8.1.15 (b2022030114)"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "@_s_n_t of @pentestltd"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to bypass authentication on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). Authentication is not required to exploit this vulnerability. The specific flaw exists within com.inductiveautomation.ignition.gateway.web.pages. The issue results from the lack of proper authentication prior to access to functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-17211."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-25T18:16:27",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1016/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2022-35869",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ignition",
"version": {
"version_data": [
{
"version_value": "8.1.15 (b2022030114)"
}
]
}
}
]
},
"vendor_name": "Inductive Automation"
}
]
}
},
"credit": "@_s_n_t of @pentestltd",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows remote attackers to bypass authentication on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). Authentication is not required to exploit this vulnerability. The specific flaw exists within com.inductiveautomation.ignition.gateway.web.pages. The issue results from the lack of proper authentication prior to access to functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-17211."
}
]
},
"impact": {
"cvss": {
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288: Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-22-1016/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1016/"
},
{
"name": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities",
"refsource": "MISC",
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2022-35869",
"datePublished": "2022-07-25T18:16:27",
"dateReserved": "2022-07-14T00:00:00",
"dateUpdated": "2024-08-03T09:44:22.094Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-1264 (GCVE-0-2022-1264)
Vulnerability from cvelistv5 – Published: 2022-07-20 15:34 – Updated: 2025-04-16 16:14
VLAI?
Summary
The affected product may allow an attacker with access to the Ignition web configuration to run arbitrary code.
Severity ?
6.8 (Medium)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Inductive Automation | Ignition |
Affected:
All 8.1 versions 8.1.10
Affected: 8.0.4 , < All 8.0 versions* (custom) |
Credits
Mashav Sapir of Claroty reported this vulnerability to CISA
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T23:55:24.550Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-102-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-1264",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:51:07.081388Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:14:44.951Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Ignition",
"vendor": "Inductive Automation",
"versions": [
{
"status": "affected",
"version": "All 8.1 versions 8.1.10"
},
{
"lessThan": "All 8.0 versions*",
"status": "affected",
"version": "8.0.4",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
}
],
"datePublic": "2022-04-12T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The affected product may allow an attacker with access to the Ignition web configuration to run arbitrary code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-20T15:34:59.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-102-03"
}
],
"solutions": [
{
"lang": "en",
"value": "Inductive Automation recommends users upgrade the Ignition software to 8.1.10 or later."
}
],
"source": {
"advisory": "ICSA-22-102-03",
"discovery": "UNKNOWN"
},
"title": "Inductive Automation Ignition",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-04-12T17:00:00.000Z",
"ID": "CVE-2022-1264",
"STATE": "PUBLIC",
"TITLE": "Inductive Automation Ignition"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ignition",
"version": {
"version_data": [
{
"version_affected": "\u003e",
"version_name": "All 8.0 versions",
"version_value": "8.0.4"
},
{
"version_name": "All 8.1 versions",
"version_value": "8.1.10"
}
]
}
}
]
},
"vendor_name": "Inductive Automation"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product may allow an attacker with access to the Ignition web configuration to run arbitrary code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-102-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-102-03"
}
]
},
"solution": [
{
"lang": "en",
"value": "Inductive Automation recommends users upgrade the Ignition software to 8.1.10 or later."
}
],
"source": {
"advisory": "ICSA-22-102-03",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-1264",
"datePublished": "2022-07-20T15:34:59.675Z",
"dateReserved": "2022-04-06T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:14:44.951Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36126 (GCVE-0-2022-36126)
Vulnerability from cvelistv5 – Published: 2022-07-16 18:59 – Updated: 2024-08-03 10:00
VLAI?
Summary
An issue was discovered in Inductive Automation Ignition before 7.9.20 and 8.x before 8.1.17. The ScriptInvoke function allows remote attackers to execute arbitrary code by supplying a Python script.
Severity ?
7.2 (High)
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:00:01.571Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/sourceincite/randy"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://srcincite.io/advisories/src-2022-0014/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Inductive Automation Ignition before 7.9.20 and 8.x before 8.1.17. The ScriptInvoke function allows remote attackers to execute arbitrary code by supplying a Python script."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:H/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-16T18:59:46",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/sourceincite/randy"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://srcincite.io/advisories/src-2022-0014/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-36126",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in Inductive Automation Ignition before 7.9.20 and 8.x before 8.1.17. The ScriptInvoke function allows remote attackers to execute arbitrary code by supplying a Python script."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:H/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653",
"refsource": "MISC",
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653"
},
{
"name": "https://github.com/sourceincite/randy",
"refsource": "MISC",
"url": "https://github.com/sourceincite/randy"
},
{
"name": "https://srcincite.io/advisories/src-2022-0014/",
"refsource": "MISC",
"url": "https://srcincite.io/advisories/src-2022-0014/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-36126",
"datePublished": "2022-07-16T18:59:46",
"dateReserved": "2022-07-16T00:00:00",
"dateUpdated": "2024-08-03T10:00:01.571Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-35890 (GCVE-0-2022-35890)
Vulnerability from cvelistv5 – Published: 2022-07-15 20:07 – Updated: 2024-08-03 09:44
VLAI?
Summary
An issue was discovered in Inductive Automation Ignition before 7.9.20 and 8.x before 8.1.17. Designer and Vision Client Session IDs are mishandled. An attacker can determine which session IDs were generated in the past and then hijack sessions assigned to these IDs via Randy.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:44:22.143Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/sourceincite/randy"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Inductive Automation Ignition before 7.9.20 and 8.x before 8.1.17. Designer and Vision Client Session IDs are mishandled. An attacker can determine which session IDs were generated in the past and then hijack sessions assigned to these IDs via Randy."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-15T20:07:28",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/sourceincite/randy"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-35890",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in Inductive Automation Ignition before 7.9.20 and 8.x before 8.1.17. Designer and Vision Client Session IDs are mishandled. An attacker can determine which session IDs were generated in the past and then hijack sessions assigned to these IDs via Randy."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653",
"refsource": "MISC",
"url": "https://support.inductiveautomation.com/hc/en-us/articles/7625759776653"
},
{
"name": "https://github.com/sourceincite/randy",
"refsource": "MISC",
"url": "https://github.com/sourceincite/randy"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-35890",
"datePublished": "2022-07-15T20:07:28",
"dateReserved": "2022-07-15T00:00:00",
"dateUpdated": "2024-08-03T09:44:22.143Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-14479 (GCVE-0-2020-14479)
Vulnerability from cvelistv5 – Published: 2022-04-01 22:17 – Updated: 2025-04-16 16:32
VLAI?
Summary
Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server
Severity ?
5.3 (Medium)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Inductive Automation | Ignition 7 Gateway |
Affected:
All , < 7.9.14
(custom)
|
|||||||
|
|||||||||
Credits
Pedro Ribeiro, Radek Domanski, Chris Anastasio (muffin), and Steven Seeley (mr_me) working with Trend Micro’s Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T12:46:34.702Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-147-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-14479",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:57:58.083822Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:32:19.854Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Ignition 7 Gateway",
"vendor": "Inductive Automation",
"versions": [
{
"lessThan": "7.9.14",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
},
{
"product": "Ignition 8 Gateway",
"vendor": "Inductive Automation",
"versions": [
{
"lessThan": "8.0.10",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Pedro Ribeiro, Radek Domanski, Chris Anastasio (muffin), and Steven Seeley (mr_me) working with Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"datePublic": "2020-07-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-01T22:17:52.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-147-01"
}
],
"source": {
"advisory": "ICSA-20-147-01",
"discovery": "EXTERNAL"
},
"title": "ICSA-20-147-01 Inductive Automation Ignition (Update B)",
"workarounds": [
{
"lang": "en",
"value": "Please note CVE-2020-14479 does not have a fix in place. Induction Automation plans to correct this vulnerability in future product versions.\nIt is recommended to restrict interaction with the service to trusted machines. Only clients and servers with a legitimate procedural relationship should be permitted to communicate with the service. This can be done in various ways, most notably with firewall rules/allow listing.\nFor more information regarding software and patches, please refer to the specified version in Inductive Automation\u2019s release notes."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-07-14T17:00:00.000Z",
"ID": "CVE-2020-14479",
"STATE": "PUBLIC",
"TITLE": "ICSA-20-147-01 Inductive Automation Ignition (Update B)"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ignition 7 Gateway",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "7.9.14"
}
]
}
},
{
"product_name": "Ignition 8 Gateway",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "8.0.10"
}
]
}
}
]
},
"vendor_name": "Inductive Automation"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Pedro Ribeiro, Radek Domanski, Chris Anastasio (muffin), and Steven Seeley (mr_me) working with Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-147-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-147-01"
}
]
},
"source": {
"advisory": "ICSA-20-147-01",
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Please note CVE-2020-14479 does not have a fix in place. Induction Automation plans to correct this vulnerability in future product versions.\nIt is recommended to restrict interaction with the service to trusted machines. Only clients and servers with a legitimate procedural relationship should be permitted to communicate with the service. This can be done in various ways, most notably with firewall rules/allow listing.\nFor more information regarding software and patches, please refer to the specified version in Inductive Automation\u2019s release notes."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-14479",
"datePublished": "2022-04-01T22:17:52.198Z",
"dateReserved": "2020-06-19T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:32:19.854Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-14520 (GCVE-0-2020-14520)
Vulnerability from cvelistv5 – Published: 2020-07-31 12:30 – Updated: 2024-08-04 12:46
VLAI?
Summary
The affected product is vulnerable to an information leak, which may allow an attacker to obtain sensitive information on the Ignition 8 (all versions prior to 8.0.13).
Severity ?
No CVSS data available.
CWE
- CWE-862 - MISSING AUTHORIZATION CWE-862
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Ignition 8 |
Affected:
All versions prior to 8.0.13
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T12:46:34.838Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-212-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Ignition 8",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions prior to 8.0.13"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to an information leak, which may allow an attacker to obtain sensitive information on the Ignition 8 (all versions prior to 8.0.13)."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "MISSING AUTHORIZATION CWE-862",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-31T12:30:53",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-212-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-14520",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ignition 8",
"version": {
"version_data": [
{
"version_value": "All versions prior to 8.0.13"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to an information leak, which may allow an attacker to obtain sensitive information on the Ignition 8 (all versions prior to 8.0.13)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "MISSING AUTHORIZATION CWE-862"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-212-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-212-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-14520",
"datePublished": "2020-07-31T12:30:53",
"dateReserved": "2020-06-19T00:00:00",
"dateUpdated": "2024-08-04T12:46:34.838Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12000 (GCVE-0-2020-12000)
Vulnerability from cvelistv5 – Published: 2020-06-09 17:54 – Updated: 2024-08-04 11:48
VLAI?
Summary
The affected product is vulnerable to the handling of serialized data. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information.
Severity ?
No CVSS data available.
CWE
- CWE-502 - DESERIALIZATION OF UNTRUSTED DATA CWE-502
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Ignition 8 Gateway |
Affected:
versions prior to 7.9.14 and 8.0.10
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.852Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-147-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Ignition 8 Gateway",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "versions prior to 7.9.14 and 8.0.10"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to the handling of serialized data. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "DESERIALIZATION OF UNTRUSTED DATA CWE-502",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-18T17:54:51",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-147-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-12000",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ignition 8 Gateway",
"version": {
"version_data": [
{
"version_value": "versions prior to 7.9.14 and 8.0.10"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to the handling of serialized data. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "DESERIALIZATION OF UNTRUSTED DATA CWE-502"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-147-01",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-147-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12000",
"datePublished": "2020-06-09T17:54:03",
"dateReserved": "2020-04-21T00:00:00",
"dateUpdated": "2024-08-04T11:48:57.852Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",