Search criteria

1 vulnerability by xmedcon_project

CVE-2025-2581 (GCVE-0-2025-2581)

Vulnerability from cvelistv5 – Published: 2025-03-21 05:00 – Updated: 2025-11-03 19:45
VLAI?
Title
xmedcon DICOM File malloc integer underflow
Summary
A vulnerability has been found in xmedcon 0.25.0 and classified as problematic. Affected by this vulnerability is the function malloc of the component DICOM File Handler. The manipulation leads to integer underflow. The attack can be launched remotely. Upgrading to version 0.25.1 is able to address this issue. It is recommended to upgrade the affected component.
CWE
Assigner
References
https://vuldb.com/?id.300541 vdb-entrytechnical-description
https://vuldb.com/?ctiid.300541 signaturepermissions-required
https://vuldb.com/?submit.522216 third-party-advisory
https://xmedcon.sourceforge.io/Main/New patch
Impacted products
Vendor Product Version
n/a xmedcon Affected: 0.25.0
Credits
0x20z (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2581",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-21T13:58:45.823380Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-21T13:58:57.379Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:45:09.550Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://lists.debian.org/debian-lts-announce/2025/07/msg00000.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "DICOM File Handler"
          ],
          "product": "xmedcon",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "0.25.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "0x20z (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in xmedcon 0.25.0 and classified as problematic. Affected by this vulnerability is the function malloc of the component DICOM File Handler. The manipulation leads to integer underflow. The attack can be launched remotely. Upgrading to version 0.25.1 is able to address this issue. It is recommended to upgrade the affected component."
        },
        {
          "lang": "de",
          "value": "In xmedcon 0.25.0 wurde eine Schwachstelle gefunden. Sie wurde als problematisch eingestuft. Das betrifft die Funktion malloc der Komponente DICOM File Handler. Durch Beeinflussen mit unbekannten Daten kann eine integer underflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Ein Aktualisieren auf die Version 0.25.1 vermag dieses Problem zu l\u00f6sen. Als bestm\u00f6gliche Massnahme wird das Einspielen eines Upgrades empfohlen."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-191",
              "description": "Integer Underflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-189",
              "description": "Numeric Error",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-21T05:00:22.250Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-300541 | xmedcon DICOM File malloc integer underflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.300541"
        },
        {
          "name": "VDB-300541 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.300541"
        },
        {
          "name": "Submit #522216 | xmedcon (X)MedCon 0.25.0 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.522216"
        },
        {
          "tags": [
            "patch"
          ],
          "url": "https://xmedcon.sourceforge.io/Main/New"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-03-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-03-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-03-20T23:59:36.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "xmedcon DICOM File malloc integer underflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-2581",
    "datePublished": "2025-03-21T05:00:22.250Z",
    "dateReserved": "2025-03-20T22:54:26.984Z",
    "dateUpdated": "2025-11-03T19:45:09.550Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}