CVE-2012-0227 (GCVE-0-2012-0227)
Vulnerability from cvelistv5 – Published: 2012-10-12 20:00 – Updated: 2024-08-06 18:16
VLAI?
Summary
Buffer overflow in the VSFlex7.VSFlexGrid ActiveX control in ComponentOne FlexGrid 7.1, as used in Open Automation Software OPC Systems.NET, allows remote attackers to cause a denial of service and possibly execute arbitrary code via a long archive file name argument to the Archive method.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T18:16:19.833Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-012-01A.pdf"
},
{
"name": "51601",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/51601"
},
{
"name": "flexgrid-activex-bo(72604)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72604"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://dsecrg.com/pages/vul/show.php?id=406"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-01-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in the VSFlex7.VSFlexGrid ActiveX control in ComponentOne FlexGrid 7.1, as used in Open Automation Software OPC Systems.NET, allows remote attackers to cause a denial of service and possibly execute arbitrary code via a long archive file name argument to the Archive method."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-28T12:57:01",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-012-01A.pdf"
},
{
"name": "51601",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/51601"
},
{
"name": "flexgrid-activex-bo(72604)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72604"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://dsecrg.com/pages/vul/show.php?id=406"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2012-0227",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer overflow in the VSFlex7.VSFlexGrid ActiveX control in ComponentOne FlexGrid 7.1, as used in Open Automation Software OPC Systems.NET, allows remote attackers to cause a denial of service and possibly execute arbitrary code via a long archive file name argument to the Archive method."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-012-01A.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-012-01A.pdf"
},
{
"name": "51601",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/51601"
},
{
"name": "flexgrid-activex-bo(72604)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72604"
},
{
"name": "http://dsecrg.com/pages/vul/show.php?id=406",
"refsource": "MISC",
"url": "http://dsecrg.com/pages/vul/show.php?id=406"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2012-0227",
"datePublished": "2012-10-12T20:00:00",
"dateReserved": "2011-12-21T00:00:00",
"dateUpdated": "2024-08-06T18:16:19.833Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:componentone:flexgrid:7.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E03BA33F-8064-4D7C-9613-789CB091A4F2\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:opcsystems:opcsystems.net:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"4.0\", \"matchCriteriaId\": \"53CFC2C0-C136-4C67-B927-28F81600AEF8\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:opcsystems:opcsystems.net:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A39574D0-B696-4383-8EA1-C547B644F45F\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Buffer overflow in the VSFlex7.VSFlexGrid ActiveX control in ComponentOne FlexGrid 7.1, as used in Open Automation Software OPC Systems.NET, allows remote attackers to cause a denial of service and possibly execute arbitrary code via a long archive file name argument to the Archive method.\"}, {\"lang\": \"es\", \"value\": \"Desbordamiento de b\\u00fafer en el control ActiveX VSFlex7.VSFlexGrid en ComponentOne FlexGrid v7.1, como el usado en Open Automation Software OPC Systems.NET, permite a atacantes remotos provocar una denegaci\\u00f3n de servicio (ca\\u00edda) o ejecutar c\\u00f3digo de su elecci\\u00f3n mediante un nombre del fichero largo como argumento sobre el m\\u00e9todo Archive.\"}]",
"evaluatorImpact": "Per: http://www.us-cert.gov/control_systems/pdf/ICSA-12-012-01A.pdf\r\n\r\n\u0027AFFECTED PRODUCTS\r\nAll versions of OPC Sytems.NET prior to Version 5.0 are affected.\u0027",
"id": "CVE-2012-0227",
"lastModified": "2024-11-21T01:34:37.307",
"metrics": "{\"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:C/I:C/A:C\", \"baseScore\": 9.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.6, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2012-10-12T20:55:02.083",
"references": "[{\"url\": \"http://dsecrg.com/pages/vul/show.php?id=406\", \"source\": \"cret@cert.org\", \"tags\": [\"Exploit\"]}, {\"url\": \"http://www.securityfocus.com/bid/51601\", \"source\": \"cret@cert.org\"}, {\"url\": \"http://www.us-cert.gov/control_systems/pdf/ICSA-12-012-01A.pdf\", \"source\": \"cret@cert.org\", \"tags\": [\"US Government Resource\"]}, {\"url\": \"https://exchange.xforce.ibmcloud.com/vulnerabilities/72604\", \"source\": \"cret@cert.org\"}, {\"url\": \"http://dsecrg.com/pages/vul/show.php?id=406\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\"]}, {\"url\": \"http://www.securityfocus.com/bid/51601\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"http://www.us-cert.gov/control_systems/pdf/ICSA-12-012-01A.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"US Government Resource\"]}, {\"url\": \"https://exchange.xforce.ibmcloud.com/vulnerabilities/72604\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "cret@cert.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2012-0227\",\"sourceIdentifier\":\"cret@cert.org\",\"published\":\"2012-10-12T20:55:02.083\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Buffer overflow in the VSFlex7.VSFlexGrid ActiveX control in ComponentOne FlexGrid 7.1, as used in Open Automation Software OPC Systems.NET, allows remote attackers to cause a denial of service and possibly execute arbitrary code via a long archive file name argument to the Archive method.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de b\u00fafer en el control ActiveX VSFlex7.VSFlexGrid en ComponentOne FlexGrid v7.1, como el usado en Open Automation Software OPC Systems.NET, permite a atacantes remotos provocar una denegaci\u00f3n de servicio (ca\u00edda) o ejecutar c\u00f3digo de su elecci\u00f3n mediante un nombre del fichero largo como argumento sobre el m\u00e9todo Archive.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":9.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:componentone:flexgrid:7.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E03BA33F-8064-4D7C-9613-789CB091A4F2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opcsystems:opcsystems.net:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.0\",\"matchCriteriaId\":\"53CFC2C0-C136-4C67-B927-28F81600AEF8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opcsystems:opcsystems.net:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A39574D0-B696-4383-8EA1-C547B644F45F\"}]}]}],\"references\":[{\"url\":\"http://dsecrg.com/pages/vul/show.php?id=406\",\"source\":\"cret@cert.org\",\"tags\":[\"Exploit\"]},{\"url\":\"http://www.securityfocus.com/bid/51601\",\"source\":\"cret@cert.org\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-012-01A.pdf\",\"source\":\"cret@cert.org\",\"tags\":[\"US Government Resource\"]},{\"url\":\"https://exchange.xforce.ibmcloud.com/vulnerabilities/72604\",\"source\":\"cret@cert.org\"},{\"url\":\"http://dsecrg.com/pages/vul/show.php?id=406\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\"]},{\"url\":\"http://www.securityfocus.com/bid/51601\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-012-01A.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]},{\"url\":\"https://exchange.xforce.ibmcloud.com/vulnerabilities/72604\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}],\"evaluatorImpact\":\"Per: http://www.us-cert.gov/control_systems/pdf/ICSA-12-012-01A.pdf\\r\\n\\r\\n\u0027AFFECTED PRODUCTS\\r\\nAll versions of OPC Sytems.NET prior to Version 5.0 are affected.\u0027\"}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…