Summary
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T19:50:05.389Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://en.securitylab.ru/lab/PT-2012-43" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2012-09-18T14:00:00Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "http://en.securitylab.ru/lab/PT-2012-43" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2012-3030", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf" }, { "name": "http://en.securitylab.ru/lab/PT-2012-43", "refsource": "MISC", "url": "http://en.securitylab.ru/lab/PT-2012-43" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2012-3030", "datePublished": "2012-09-18T14:00:00Z", "dateReserved": "2012-05-30T00:00:00Z", "dateUpdated": "2024-09-16T20:27:37.541Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2012-3030\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2012-09-18T14:55:01.443\",\"lastModified\":\"2012-12-20T05:00:00.000\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.\"},{\"lang\":\"es\",\"value\":\"WebNavigator en Siemens WinCC v7.0 SP3 y anteriores, como las usadas en SIMATIC PCS7 y otros productos, almacena informaci\u00f3n sensible bajo l directorio web raiz con un control de acceso no suficiente, lo que permite a atacantes remotos a leer (1) ficheros de registro o (2) ficheros de configuraci\u00f3n a trav\u00e9s de una petici\u00f3n directa.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-264\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8B894F4-9635-4436-BC0A-E43280426017\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.0\",\"matchCriteriaId\":\"5AC094B0-B1BE-436D-A8D3-2008D0CDE070\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B4CB277F-7ECB-4F44-8BB5-A3D350486EE7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"616535F1-F609-408B-AE48-61ACF48748A1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7F322FCB-32F4-4C5A-A7F5-F7EF41188C88\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"69822DB4-DC79-4F88-A470-5AC512C77377\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"996DE8BD-DD51-41EF-9882-C2BD2CC5FE53\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*\",\"matchCriteriaId\":\"945C8B46-4CDA-4143-889C-30E30E93DB29\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A33F9015-7058-419A-8762-CB2AE4ACF1A7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"E6271FCC-CCF6-4D31-801A-B4B0DC4639DD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF7A6B2B-D573-4285-B3B4-136F2BE7E710\"}]}]}],\"references\":[{\"url\":\"http://en.securitylab.ru/lab/PT-2012-43\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"US Government Resource\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.