Summary
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T13:18:48.641Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2014-11-21T00:00:00", "descriptions": [ { "lang": "en", "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2014-11-26T06:57:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2014-8552", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2014-8552", "datePublished": "2014-11-26T11:00:00", "dateReserved": "2014-10-30T00:00:00", "dateUpdated": "2024-08-06T13:18:48.641Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2014-8552\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2014-11-26T11:59:01.373\",\"lastModified\":\"2014-11-26T16:54:50.050\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.\"},{\"lang\":\"es\",\"value\":\"El servidor WinCC en Siemens SIMATIC WinCC 7.0 hasta SP3, 7.2 anterior a la actualizaci\u00f3n 9, y 7.3 anterior a la actualizaci\u00f3n 2; SIMATIC PCS 7 7.1 hasta SP4, 8.0 hasta SP2; y 8.1; y TIA Portal 13 anterior a la actualizaci\u00f3n 6 permite a atacantes remotos leer ficheros arbitrarios a trav\u00e9s de paquetes manipulados.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs_7:7.1:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"BE258BF2-AD82-401C-B020-08A22A549A25\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:7.1:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"33FA164B-E269-4140-AC85-2623356AF636\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:7.1:sp4:*:*:*:*:*:*\",\"matchCriteriaId\":\"D62C7959-87D9-42EC-A224-2EE6EF23C1CF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:8.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"428F68D2-8C1D-4ADE-A6FB-65EC4C426F99\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:8.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"14193511-1B9B-4319-92AE-BB26F398550C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:8.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"172A6A81-C32E-4ACC-AB8C-2014BF3A6901\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_tiaportal:13.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"19C3A00B-A47E-4723-B652-B64FDC5F2601\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_tiaportal:13.0:3:*:*:*:*:*:*\",\"matchCriteriaId\":\"144DE778-4439-489F-830D-B4742BB11FEB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_tiaportal:13.0:5:*:*:*:*:*:*\",\"matchCriteriaId\":\"39B75B5E-7979-4E3B-BE94-AE04F17A6F3C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3CF84FC5-9450-47B7-A4F0-99361C528C00\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8274939-833E-40E1-8D2E-1B28CEA91036\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"61F46206-F232-4F62-AF4F-E2DCF462AE60\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.0:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"0D0BB2E6-1444-499A-943E-8D19C402F1BD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.2:1:*:*:*:*:*:*\",\"matchCriteriaId\":\"2D6E154F-F8A0-4E9D-BC37-E95B1820D2BF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.2:2:*:*:*:*:*:*\",\"matchCriteriaId\":\"D6745F96-FA72-457B-AD14-07C4B353310F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.2:3:*:*:*:*:*:*\",\"matchCriteriaId\":\"E555D458-59C4-4CBC-95F4-CBA503BCCB24\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.2:4:*:*:*:*:*:*\",\"matchCriteriaId\":\"3BEE67FC-D188-4B0C-A837-FC91B406982E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.2:5:*:*:*:*:*:*\",\"matchCriteriaId\":\"75121F46-303D-4416-8FBD-1938BDD60AAB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.2:6:*:*:*:*:*:*\",\"matchCriteriaId\":\"FF8B251F-399E-4165-B3A6-801775212C5D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.2:7:*:*:*:*:*:*\",\"matchCriteriaId\":\"FBE45DD1-630F-448F-90FE-D3CC00266EF1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.2:8:*:*:*:*:*:*\",\"matchCriteriaId\":\"CFC7DC1F-B4C5-4116-9B53-706F2B3227DD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.3:1:*:*:*:*:*:*\",\"matchCriteriaId\":\"B8F27E75-90CD-4C3B-AF0E-90EF338A2D91\"}]}]}],\"references\":[{\"url\":\"http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.