Action not permitted
Modal body text goes here.
CVE-2016-9952
Vulnerability from cvelistv5
Published
2018-03-12 21:00
Modified
2024-08-07 19:19
Severity ?
EPSS score ?
Summary
The verify_certificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, makes it easier for remote attackers to conduct man-in-the-middle attacks via a crafted wildcard SAN in a server certificate, as demonstrated by "*.com."
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://curl.haxx.se/CVE-2016-9952.patch | Vendor Advisory | |
cve@mitre.org | https://curl.haxx.se/docs/adv_20161221B.html | Vendor Advisory |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:haxx:curl:7.27.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "curl", "vendor": "haxx", "versions": [ { "lessThanOrEqual": "7.51.0", "status": "affected", "version": "7.27.0", "versionType": "custom" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2016-9952", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-23T19:19:07.163022Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-295", "description": "CWE-295 Improper Certificate Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-07T19:19:13.575Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-06T03:07:31.068Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://curl.haxx.se/docs/adv_20161221B.html" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://curl.haxx.se/CVE-2016-9952.patch" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2016-12-21T00:00:00", "descriptions": [ { "lang": "en", "value": "The verify_certificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, makes it easier for remote attackers to conduct man-in-the-middle attacks via a crafted wildcard SAN in a server certificate, as demonstrated by \"*.com.\"" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-03-12T20:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://curl.haxx.se/docs/adv_20161221B.html" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://curl.haxx.se/CVE-2016-9952.patch" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2016-9952", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The verify_certificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, makes it easier for remote attackers to conduct man-in-the-middle attacks via a crafted wildcard SAN in a server certificate, as demonstrated by \"*.com.\"" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://curl.haxx.se/docs/adv_20161221B.html", "refsource": "CONFIRM", "url": "https://curl.haxx.se/docs/adv_20161221B.html" }, { "name": "https://curl.haxx.se/CVE-2016-9952.patch", "refsource": "CONFIRM", "url": "https://curl.haxx.se/CVE-2016-9952.patch" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2016-9952", "datePublished": "2018-03-12T21:00:00", "dateReserved": "2016-12-15T00:00:00", "dateUpdated": "2024-08-07T19:19:13.575Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2016-9952\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2018-03-12T21:29:00.500\",\"lastModified\":\"2024-08-01T13:41:30.963\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The verify_certificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, makes it easier for remote attackers to conduct man-in-the-middle attacks via a crafted wildcard SAN in a server certificate, as demonstrated by \\\"*.com.\\\"\"},{\"lang\":\"es\",\"value\":\"La funci\u00f3n verify_certificate en lib/vtls/schannel.c en libcurl, desde la versi\u00f3n 7.30.0 hasta la 7.51.0, cuando se construye para Windows CE usando el backend TLS schannel, facilita la ejecuci\u00f3n de ataques Man-in-the-Middle (MitM) por parte de atacantes remotos mediante un wildcard SAN manipulado en un certificado de servidor, tal y como demuestra \\\"*.com\\\".\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-295\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-295\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:haxx:curl:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.30.0\",\"versionEndIncluding\":\"7.51.0\",\"matchCriteriaId\":\"25ACEC30-625F-46E6-8F95-5550CEA47EF8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_embedded_compact:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"48927A5E-B938-4D59-84E1-4C05AA80F69C\"}]}]}],\"references\":[{\"url\":\"https://curl.haxx.se/CVE-2016-9952.patch\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://curl.haxx.se/docs/adv_20161221B.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
icsa-19-155-01
Vulnerability from csaf_cisa
Published
2019-06-04 00:00
Modified
2019-06-04 00:00
Summary
PHOENIX CONTACT PLCNext AXC F 2152
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to decrypt passwords, bypass authentication, and deny service to the device. In addition, these vulnerabilities could interact with third-party vulnerabilities to cause other impacts to integrity, confidentiality, and availability.
Critical infrastructure sectors
Commercial Facilities
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
NCCIC recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:
Recommended Practices
NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.
Recommended Practices
NCCIC also recommends that users take the following measures to protect themselves from social engineering attacks:
Exploitability
No known public exploits specifically target these vulnerabilities.
{ "document": { "acknowledgments": [ { "names": [ "Zahra Khani" ], "organization": "Firmalyzer", "summary": "reporting some of these vulnerabilities to NCCIC" }, { "organization": "OPC Foundation", "summary": "reporting some of these vulnerabilities to Phoenix Contact" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to decrypt passwords, bypass authentication, and deny service to the device. In addition, these vulnerabilities could interact with third-party vulnerabilities to cause other impacts to integrity, confidentiality, and availability.", "title": "Risk evaluation" }, { "category": "other", "text": "Commercial Facilities", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC also recommends that users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-19-155-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-155-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-19-155-01 - Web Scraped Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-155-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-155-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-155-01" } ], "title": "PHOENIX CONTACT PLCNext AXC F 2152", "tracking": { "current_release_date": "2019-06-04T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-155-01", "initial_release_date": "2019-06-04T00:00:00.000000Z", "revision_history": [ { "date": "2019-06-04T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-19-155-01 PHOENIX CONTACT PLCNext AXC F 2152" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "2404267 version 1.x", "product": { "name": "AXC F 2152: article number 2404267 version 1.x", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "AXC F 2152" }, { "branches": [ { "category": "product_version_range", "name": "1046568 (Starterkit) version 1.x", "product": { "name": "AXC F 2152: article number 1046568 (Starterkit) version 1.x", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "AXC F 2152" } ], "category": "vendor", "name": "Phoenix Contact" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-7559", "cwe": { "id": "CWE-326", "name": "Inadequate Encryption Strength" }, "notes": [ { "category": "summary", "text": "A remote attacker can exploit a server \u0027s private key by sending carefully constructed UserIdentityTokens encrypted with the Basic128Rsa15 security policy. This could allow an attacker to decrypt passwords even if encrypted with another security policy such as Basic256Sha256. CVE-2018-7559 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7559" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:L" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2019-10998", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "An attacker with physical access to the device can manipulate SD card data, which could allow an attacker to bypass the authentication of the device. This device is designed for use in a protected industrial environment with restricted physical access.CVE-2019-10998 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-10998" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 6.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2019-10997", "cwe": { "id": "CWE-300", "name": "Channel Accessible by Non-Endpoint" }, "notes": [ { "category": "summary", "text": "An attacker trying to connect to the device using a man-in-the-middle setup may crash the PLC service, resulting in a denial of service condition. The device must then be rebooted, or the PLC service must be restarted manually via Linux shell.CVE-2019-10997 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-10997" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-8816", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "The NTLM authentication feature in curl and libcurl before 7.57.0 on 32-bit platforms allows attackers to cause a denial of service (integer overflow and resultant buffer overflow, and application crash) or possibly have unspecified other impact via vectors involving long user and password fields.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-8816" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "environmentalScore": 9.8, "environmentalSeverity": "CRITICAL", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "temporalScore": 9.8, "temporalSeverity": "CRITICAL", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-9953", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The verify_certificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, allows remote attackers to obtain sensitive information, cause a denial of service (crash), or possibly have unspecified other impact via a wildcard certificate name, which triggers an out-of-bounds read.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2016-9953" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "environmentalScore": 9.8, "environmentalSeverity": "CRITICAL", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "temporalScore": 9.8, "temporalSeverity": "CRITICAL", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-8817", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The FTP wildcard function in curl and libcurl before 7.57.0 allows remote attackers to cause a denial of service (out-of-bounds read and application crash) or possibly have unspecified other impact via a string that ends with an \u0027[\u0027 character.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-8817" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-11541", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "tcpdump 4.9.0 has a heap-based buffer over-read in the lldp_print function in print-lldp.c, related to util-print.c.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-11541" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-11542", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "tcpdump 4.9.0 has a heap-based buffer over-read in the pimv1_print function in print-pim.c.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-11542" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-11543", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "tcpdump 4.9.0 has a buffer overflow in the sliplink_print function in print-sl.c.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-11543" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-5334", "cwe": { "id": "CWE-415", "name": "Double Free" }, "notes": [ { "category": "summary", "text": "Double free vulnerability in the gnutls_x509_ext_import_proxy function in GnuTLS before 3.3.26 and 3.5.x before 3.5.8 allows remote attackers to have unspecified impact via crafted policy language information in an X.509 certificate with a Proxy Certificate Information extension.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-5334" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-5336", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "Stack-based buffer overflow in the cdk_pk_get_keyid function in lib/opencdk/pubkey.c in GnuTLS before 3.3.26 and 3.5.x before 3.5.8 allows remote attackers to have unspecified impact via a crafted OpenPGP certificate.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-5336" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-9841", "cwe": { "id": "CWE-823", "name": "Use of Out-of-range Pointer Offset" }, "notes": [ { "category": "summary", "text": "inffast.c in zlib 1.2.8 might allow context-dependent attackers to have unspecified impact by leveraging improper pointer arithmetic.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-9841" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2018-1000120", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A buffer overflow exists in curl 7.12.3 to and including curl 7.58.0 in the FTP URL handling that allows an attacker to cause a denial of service or worse.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-1000120" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-5337", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "Multiple heap-based buffer overflows in the read_attribute function in GnuTLS before 3.3.26 and 3.5.x before 3.5.8 allow remote attackers to have unspecified impact via a crafted OpenPGP certificate.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-5337" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-9843", "cwe": { "id": "CWE-354", "name": "Improper Validation of Integrity Check Value" }, "notes": [ { "category": "summary", "text": "The crc32_big function in crc32.c in zlib 1.2.8 might allow context-dependent attackers to have unspecified impact via vectors involving big-endian CRC calculation.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-9843" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-1000257", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "An IMAP FETCH response line indicates the size of the returned data, in number of bytes. When that response says the data is zero bytes, libcurl would pass on that (non-existing) data with a pointer and the size (zero) to the deliver-data function. libcurl\u0027s deliver-data function treats zero as a magic number and invokes strlen() on the data to figure out the length. The strlen() is called on a heap based buffer that might not be zero terminated so libcurl might read beyond the end of it into whatever memory lies after (or just crash) and then deliver that to the application as if it was actually downloaded.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-1000257" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2018-1000122", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "A buffer over-read exists in curl 7.20.0 to and including curl 7.58.0 in the RTSP+RTP handling code that allows an attacker to cause a denial of service or information leakage", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-1000122" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2018-1000301", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "curl version curl 7.20.0 to and including curl 7.59.0 contains a CWE-126: Buffer Over-read vulnerability in denial of service that can result in curl can be tricked into reading data beyond the end of a heap based buffer used to store downloaded RTSP content.. This vulnerability appears to have been fixed in curl \u003c 7.20.0 and curl \u003e= 7.60.0.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-1000301" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2018-1000005", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "libcurl 7.49.0 to and including 7.57.0 contains an out bounds read in code handling HTTP/2 trailers. It was reported (https://github.com/curl/curl/pull/2231) that reading an HTTP/2 trailer could mess up future trailers since the stored size was one byte less than required. The problem is that the code that creates HTTP/1-like headers from the HTTP/2 trailer data once appended a string like `:` to the target buffer, while this was recently changed to `: ` (a space was added after the colon) but the following math wasn\u0027t updated correspondingly. When accessed, the data is read out of bounds and causes either a crash or that the (too large) data gets passed to client write. This could lead to a denial-of-service situation or an information disclosure if someone has a service that echoes back or uses the trailers for something.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-1000005" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-9842", "cwe": { "id": "CWE-1335", "name": "Incorrect Bitwise Shift of Integer" }, "notes": [ { "category": "summary", "text": "The inflateMark function in inflate.c in zlib 1.2.8 might allow context-dependent attackers to have unspecified impact via vectors involving left shifts of negative integers.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-9842" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-9840", "cwe": { "id": "CWE-823", "name": "Use of Out-of-range Pointer Offset" }, "notes": [ { "category": "summary", "text": "inftrees.c in zlib 1.2.8 might allow context-dependent attackers to have unspecified impact by leveraging improper pointer arithmetic.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-9840" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-9952", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "The verify_certificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, makes it easier for remote attackers to conduct man-in-the-middle attacks via a crafted wildcard SAN in a server certificate, as demonstrated by \"*.com.\"", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-9952" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-1247", "cwe": { "id": "CWE-59", "name": "Improper Link Resolution Before File Access (\u0027Link Following\u0027)" }, "notes": [ { "category": "summary", "text": "The nginx package before 1.6.2-5+deb8u3 on Debian jessie, the nginx packages before 1.4.6-1ubuntu3.6 on Ubuntu 14.04 LTS, before 1.10.0-0ubuntu0.16.04.3 on Ubuntu 16.04 LTS, and before 1.10.1-0ubuntu1.1 on Ubuntu 16.10, and the nginx ebuild before 1.10.2-r3 on Gentoo allow local users with access to the web server user account to gain root privileges via a symlink attack on the error log.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-1247" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-9023", "cwe": { "id": "CWE-835", "name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)" }, "notes": [ { "category": "summary", "text": "The ASN.1 parser in strongSwan before 5.5.3 improperly handles CHOICE types when the x509 plugin is enabled, which allows remote attackers to cause a denial of service (infinite loop) via a crafted certificate.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-9023" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-6301", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The recv_and_process_client_pkt function in networking/ntpd.c in busybox allows remote attackers to cause a denial of service (CPU and bandwidth consumption) via a forged NTP packet, which triggers a communication loop.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-6301" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-7141", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "curl and libcurl before 7.50.2, when built with NSS and the libnsspem.so library is available at runtime, allow remote attackers to hijack the authentication of a TLS connection by leveraging reuse of a previously loaded client certificate from file for a connection for which no certificate has been set, a different vulnerability than CVE-2016-5420.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7141" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-7444", "cwe": { "id": "CWE-130", "name": "Improper Handling of Length Parameter Inconsistency" }, "notes": [ { "category": "summary", "text": "The gnutls_ocsp_resp_check_crt function in lib/x509/ocsp.c in GnuTLS before 3.4.15 and 3.5.x before 3.5.4 does not verify the serial length of an OCSP response, which might allow remote attackers to bypass an intended certificate validation mechanism via vectors involving trailing bytes left by gnutls_malloc.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7444" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2018-1000121", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference exists in curl 7.21.0 to and including curl 7.58.0 in the LDAP code that allows an attacker to cause a denial of service", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-1000121" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-1000254", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "libcurl may read outside of a heap allocated buffer when doing FTP. When libcurl connects to an FTP server and successfully logs in (anonymous or not), it asks the server for the current directory with the `PWD` command. The server then responds with a 257 response containing the path, inside double quotes. The returned path name is then kept by libcurl for subsequent uses. Due to a flaw in the string parser for this directory name, a directory name passed like this but without a closing double quote would lead to libcurl not adding a trailing NUL byte to the buffer holding the name. When libcurl would then later access the string, it could read beyond the allocated heap buffer and crash or wrongly access data beyond the buffer, thinking it was part of the path. A malicious server could abuse this fact and effectively prevent libcurl-based clients to work with it - the PWD command is always issued on new FTP connections and the mistake has a high chance of causing a segfault. The simple fact that this has issue remained undiscovered for this long could suggest that malformed PWD responses are rare in benign servers. We are not aware of any exploit of this flaw. This bug was introduced in commit [415d2e7cb7](https://github.com/curl/curl/commit/415d2e7cb7), March 2005. In libcurl version 7.56.0, the parser always zero terminates the string but also rejects it if not terminated properly with a final double quote.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-1000254" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-11108", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "tcpdump 4.9.0 allows remote attackers to cause a denial of service (heap-based buffer over-read and application crash) via crafted packet data. The crash occurs in the EXTRACT_16BITS function, called from the stp_print function for the Spanning Tree Protocol.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-11108" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-11185", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The gmp plugin in strongSwan before 5.6.0 allows remote attackers to cause a denial of service (NULL pointer dereference and daemon crash) via a crafted RSA signature.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-11185" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-3731", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "If an SSL/TLS server or client is running on a 32-bit host, and a specific cipher is being used, then a truncated packet can cause that server or client to perform an out-of-bounds read, usually resulting in a crash. For OpenSSL 1.1.0, the crash can be triggered when using CHACHA20/POLY1305; users should upgrade to 1.1.0d. For Openssl 1.0.2, the crash can be triggered when using RC4-MD5; users who have not disabled that algorithm should update to 1.0.2k.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-3731" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-9233", "cwe": { "id": "CWE-835", "name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)" }, "notes": [ { "category": "summary", "text": "XML External Entity vulnerability in libexpat 2.2.0 and earlier (Expat XML Parser Library) allows attackers to put the parser in an infinite loop using a malformed external entity definition from an external DTD.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-9233" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-5335", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The stream reading functions in lib/opencdk/read-packet.c in GnuTLS before 3.3.26 and 3.5.x before 3.5.8 allow remote attackers to cause a denial of service (out-of-memory error and crash) via a crafted OpenPGP certificate.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-5335" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-9022", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The gmp plugin in strongSwan before 5.5.3 does not properly validate RSA public keys before calling mpz_powm_sec, which allows remote peers to cause a denial of service (floating point exception and process crash) via a crafted certificate.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-9022" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2018-1000117", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "Python Software Foundation CPython version From 3.2 until 3.6.4 on Windows contains a Buffer Overflow vulnerability in os.symlink() function on Windows that can result in Arbitrary code execution, likely escalation of privilege. This attack appears to be exploitable via a python script that creates a symlink with an attacker controlled name or location. This vulnerability appears to have been fixed in 3.7.0 and 3.6.5.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-1000117" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2018-5388", "cwe": { "id": "CWE-124", "name": "Buffer Underwrite (\u0027Buffer Underflow\u0027)" }, "notes": [ { "category": "summary", "text": "In stroke_socket.c in strongSwan before 5.6.3, a missing packet length check could allow a buffer underflow, which may lead to resource exhaustion and denial of service while reading from the socket.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-5388" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-1000101", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "curl supports \"globbing\" of URLs, in which a user can pass a numerical range to have the tool iterate over those numbers to do a sequence of transfers. In the globbing function that parses the numerical range, there was an omission that made curl read a byte beyond the end of the URL if given a carefully crafted, or just wrongly written, URL. The URL is stored in a heap based buffer, so it could then be made to wrongly read something else instead of crashing. An example of a URL that triggers the flaw would be `http://ur%20[0-60000000000000000000`.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-1000101" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-1000100", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "When doing a TFTP transfer and curl/libcurl is given a URL that contains a very long file name (longer than about 515 bytes), the file name is truncated to fit within the buffer boundaries, but the buffer size is still wrongly updated to use the untruncated length. This too large value is then used in the sendto() call, making curl attempt to send more data than what is actually put into the buffer. The endto() function will then read beyond the end of the heap based buffer. A malicious HTTP(S) server could redirect a vulnerable libcurl-using client to a crafted TFTP URL (if the client hasn\u0027t restricted which protocols it allows redirects to) and trick it to send private memory contents to a remote server over UDP. Limit curl\u0027s redirect protocols with --proto-redir and libcurl\u0027s with CURLOPT_REDIR_PROTOCOLS.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-1000100" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-7103", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "Cross-site scripting (XSS) vulnerability in jQuery UI before 1.12.0 might allow remote attackers to inject arbitrary web script or HTML via the closeText parameter of the dialog function.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7103" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2015-9251", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "jQuery before 3.0.0 is vulnerable to Cross-site Scripting (XSS) attacks when a cross-domain Ajax request is performed without the dataType option, causing text/javascript responses to be executed.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2015-9251" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-3738", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "There is an overflow bug in the AVX2 Montgomery multiplication procedure used in exponentiation with 1024-bit moduli. No EC algorithms are affected. Analysis suggests that attacks against RSA and DSA as a result of this defect would be very difficult to perform and are not believed likely. Attacks against DH1024 are considered just feasible, because most of the work necessary to deduce information about a private key may be performed offline. The amount of resources required for such an attack would be significant. However, for an attack on TLS to be meaningful, the server would have to share the DH1024 private key among multiple clients, which is no longer an option since CVE-2016-0701. This only affects processors that support the AVX2 but not ADX extensions like Intel Haswell (4th generation). Note: The impact from this issue is similar to CVE-2017-3736, CVE-2017-3732 and CVE-2015-3193. OpenSSL version 1.0.2-1.0.2m and 1.1.0-1.1.0g are affected. Fixed in OpenSSL 1.0.2n. Due to the low severity of this issue we are not issuing a new release of OpenSSL 1.1.0 at this time. The fix will be included in OpenSSL 1.1.0h when it becomes available. The fix is also available in commit e502cc86d in the OpenSSL git repository.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-3738" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2018-0737", "cwe": { "id": "CWE-327", "name": "Use of a Broken or Risky Cryptographic Algorithm" }, "notes": [ { "category": "summary", "text": "The OpenSSL RSA Key generation algorithm has been shown to be vulnerable to a cache timing side channel attack. An attacker with sufficient access to mount cache timing attacks during the RSA key generation process could recover the private key. Fixed in OpenSSL 1.1.0i-dev (Affected 1.1.0-1.1.0h). Fixed in OpenSSL 1.0.2p-dev (Affected 1.0.2b-1.0.2o).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-0737" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-3737", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "OpenSSL 1.0.2 (starting from version 1.0.2b) introduced an \"error state\" mechanism. The intent was that if a fatal error occurred during a handshake then OpenSSL would move into the error state and would immediately fail if you attempted to continue the handshake. This works as designed for the explicit handshake functions (SSL_do_handshake(), SSL_accept() and SSL_connect()), however due to a bug it does not work correctly if SSL_read() or SSL_write() is called directly. In that scenario, if the handshake fails then a fatal error will be returned in the initial function call. If SSL_read()/SSL_write() is subsequently called by the application for the same SSL object then it will succeed and the data is passed without being decrypted/encrypted directly from the SSL/TLS record layer. In order to exploit this issue an application bug would have to be present that resulted in a call to SSL_read()/SSL_write() being issued after having already received a fatal error. OpenSSL version 1.0.2b-1.0.2m are affected. Fixed in OpenSSL 1.0.2n. OpenSSL 1.1.0 is not affected.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-3737" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-15906", "cwe": { "id": "CWE-269", "name": "Improper Privilege Management" }, "notes": [ { "category": "summary", "text": "The process_open function in sftp-server.c in OpenSSH before 7.6 does not properly prevent write operations in readonly mode, which allows attackers to create zero-length files.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-15906" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2017-3735", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "While parsing an IPAddressFamily extension in an X.509 certificate, it is possible to do a one-byte overread. This would result in an incorrect text display of the certificate. This bug has been present since 2006 and is present in all versions of OpenSSL before 1.0.2m and 1.1.0g.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-3735" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Phoenix Contact recommends affected users update to firmware release 2019.0 LTS or later, update to PLCNext Engineer release 2019.0 LTS or later, and apply the following specific mitigations below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Disable Basic128Rsa15 security policy in OPC Servers configuration. Use only Basic256 or higher.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Follow the advice concerning SD card usage in the manual \u201cArt.-Nr. 107708: UM EN AXC F 2152 Installing, starting up, and operating the AXC F 2152 controller um_en_axc_f_2152_107708_en_02.pdf\u201d that can be found on the product page below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/online/portal/us/?uri=pxc-oc-itemdetail:pid=2404267\u0026library=usen\u0026pcck=P-21-14-01\u0026tab=1\u0026selectedCategory=ALL" }, { "category": "mitigation", "details": "Use the notification manager to monitor SD card exchanges by the application program.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Subscribe to PSIRT news as updates on the SD card vulnerability will be provided in the future.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Phoenix Contact also recommends users operate the devices in closed networks or environments protected with a suitable firewall. For detailed information on recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note \u201cArt.-Nr. 107913: AH EN INDUSTRIAL SECURITY - Measures to protect network-capable devices with Ethernet connection against unauthorized access,\u201d which can be found at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.phoenixcontact.com/assets/downloads_ed/local_pc/web_dwl_technical_info/ah_en_industrial_security_107913_en_01.pdf" }, { "category": "mitigation", "details": "For more information, CERT@VDE has released a security advisory available at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert.vde.com/en-us/advisories/vde-2019-009" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] } ] }
ghsa-j357-mfhx-p456
Vulnerability from github
Published
2022-05-14 03:32
Modified
2022-05-14 03:32
Severity ?
Details
The verify_certificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, makes it easier for remote attackers to conduct man-in-the-middle attacks via a crafted wildcard SAN in a server certificate, as demonstrated by "*.com."
{ "affected": [], "aliases": [ "CVE-2016-9952" ], "database_specific": { "cwe_ids": [ "CWE-295" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2018-03-12T21:29:00Z", "severity": "HIGH" }, "details": "The verify_certificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, makes it easier for remote attackers to conduct man-in-the-middle attacks via a crafted wildcard SAN in a server certificate, as demonstrated by \"*.com.\"", "id": "GHSA-j357-mfhx-p456", "modified": "2022-05-14T03:32:30Z", "published": "2022-05-14T03:32:30Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2016-9952" }, { "type": "WEB", "url": "https://curl.haxx.se/CVE-2016-9952.patch" }, { "type": "WEB", "url": "https://curl.haxx.se/docs/adv_20161221B.html" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
gsd-2016-9952
Vulnerability from gsd
Modified
2023-12-13 01:21
Details
The verify_certificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, makes it easier for remote attackers to conduct man-in-the-middle attacks via a crafted wildcard SAN in a server certificate, as demonstrated by "*.com."
Aliases
Aliases
{ "GSD": { "alias": "CVE-2016-9952", "description": "The verify_certificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, makes it easier for remote attackers to conduct man-in-the-middle attacks via a crafted wildcard SAN in a server certificate, as demonstrated by \"*.com.\"", "id": "GSD-2016-9952", "references": [ "https://www.suse.com/security/cve/CVE-2016-9952.html" ] }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2016-9952" ], "details": "The verify_certificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, makes it easier for remote attackers to conduct man-in-the-middle attacks via a crafted wildcard SAN in a server certificate, as demonstrated by \"*.com.\"", "id": "GSD-2016-9952", "modified": "2023-12-13T01:21:21.405082Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2016-9952", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The verify_certificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, makes it easier for remote attackers to conduct man-in-the-middle attacks via a crafted wildcard SAN in a server certificate, as demonstrated by \"*.com.\"" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://curl.haxx.se/docs/adv_20161221B.html", "refsource": "CONFIRM", "url": "https://curl.haxx.se/docs/adv_20161221B.html" }, { "name": "https://curl.haxx.se/CVE-2016-9952.patch", "refsource": "CONFIRM", "url": "https://curl.haxx.se/CVE-2016-9952.patch" } ] } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:haxx:curl:*:*:*:*:*:*:*:*", "matchCriteriaId": "25ACEC30-625F-46E6-8F95-5550CEA47EF8", "versionEndIncluding": "7.51.0", "versionStartIncluding": "7.30.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_embedded_compact:-:*:*:*:*:*:*:*", "matchCriteriaId": "48927A5E-B938-4D59-84E1-4C05AA80F69C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "descriptions": [ { "lang": "en", "value": "The verify_certificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, makes it easier for remote attackers to conduct man-in-the-middle attacks via a crafted wildcard SAN in a server certificate, as demonstrated by \"*.com.\"" }, { "lang": "es", "value": "La funci\u00f3n verify_certificate en lib/vtls/schannel.c en libcurl, desde la versi\u00f3n 7.30.0 hasta la 7.51.0, cuando se construye para Windows CE usando el backend TLS schannel, facilita la ejecuci\u00f3n de ataques Man-in-the-Middle (MitM) por parte de atacantes remotos mediante un wildcard SAN manipulado en un certificado de servidor, tal y como demuestra \"*.com\"." } ], "id": "CVE-2016-9952", "lastModified": "2023-12-15T19:06:18.803", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-03-12T21:29:00.500", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://curl.haxx.se/CVE-2016-9952.patch" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://curl.haxx.se/docs/adv_20161221B.html" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-295" } ], "source": "nvd@nist.gov", "type": "Primary" } ] } } } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.