Summary
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 7.5 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H).
References
▼ | URL | Tags | |
---|---|---|---|
secalert_us@oracle.com | http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html | Patch, Vendor Advisory | |
secalert_us@oracle.com | http://www.securityfocus.com/bid/99855 | Third Party Advisory, VDB Entry |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T17:25:00.567Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "99855", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/99855" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2017-10016", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-04T15:39:58.016951Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-04T19:13:08.104Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Sun ZFS Storage Appliance Kit (AK) Software", "vendor": "Oracle Corporation", "versions": [ { "status": "affected", "version": "AK 2013" } ] } ], "datePublic": "2017-07-18T00:00:00", "descriptions": [ { "lang": "en", "value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 7.5 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H)." } ], "problemTypes": [ { "descriptions": [ { "description": "Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-08-09T09:57:01", "orgId": "43595867-4340-4103-b7a2-9a5208d29a85", "shortName": "oracle" }, "references": [ { "name": "99855", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/99855" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secalert_us@oracle.com", "ID": "CVE-2017-10016", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Sun ZFS Storage Appliance Kit (AK) Software", "version": { "version_data": [ { "version_affected": "=", "version_value": "AK 2013" } ] } } ] }, "vendor_name": "Oracle Corporation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 7.5 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK)." } ] } ] }, "references": { "reference_data": [ { "name": "99855", "refsource": "BID", "url": "http://www.securityfocus.com/bid/99855" }, { "name": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html", "refsource": "CONFIRM", "url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "43595867-4340-4103-b7a2-9a5208d29a85", "assignerShortName": "oracle", "cveId": "CVE-2017-10016", "datePublished": "2017-08-08T15:00:00", "dateReserved": "2017-06-21T00:00:00", "dateUpdated": "2024-10-04T19:13:08.104Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2017-10016\",\"sourceIdentifier\":\"secalert_us@oracle.com\",\"published\":\"2017-08-08T15:29:00.647\",\"lastModified\":\"2019-10-03T00:03:26.223\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 7.5 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H).\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad en el componente Sun ZFS Storage Appliance Kit (AK) de Oracle Sun Systems Products Suite (subcomponente: User Interface). La versi\u00f3n compatible afectada es la AK 2013. Una vulnerabilidad dif\u00edcilmente explotable permite que un atacante sin autenticar con acceso a red por HTTP comprometa la seguridad de Sun ZFS Storage Appliance Kit (AK). Para que los ataques tengan \u00e9xito, se necesita la participaci\u00f3n de otra persona diferente del atacante. Los ataques exitosos a esta vulnerabilidad pueden resultar en la toma de control de Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 7.5 (Impactos en la confidencialidad, integridad y disponibilidad). Vector CVSS: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H).\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.6,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:H/Au:N/C:C/I:C/A:C\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"HIGH\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":7.6},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":4.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:sun_zfs_storage_appliance_kit_software:2013:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D06E5C2E-66BF-434F-9137-B256450C00EE\"}]}]}],\"references\":[{\"url\":\"http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html\",\"source\":\"secalert_us@oracle.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/99855\",\"source\":\"secalert_us@oracle.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.