A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller.
CWE
  • Buffer Overflow
References
Impacted products
Vendor Product Version CPE status
Schneider Electric SE SoMachine HVAC Programming Software Affected: v2.1.0 for Modicon M171/M172 Controllers
guessed Create a notification for this product.
Date Public
2017-05-05 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.459Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
          },
          {
            "name": "98449",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/98449"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SoMachine HVAC Programming Software",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "v2.1.0 for Modicon M171/M172 Controllers"
            }
          ]
        }
      ],
      "datePublic": "2017-05-05T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric\u0027s SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-06-08T09:57:01.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
        },
        {
          "name": "98449",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/98449"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2017-7965",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SoMachine HVAC Programming Software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v2.1.0 for Modicon M171/M172 Controllers"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric\u0027s SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/",
              "refsource": "CONFIRM",
              "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
            },
            {
              "name": "98449",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/98449"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2017-7965",
    "datePublished": "2017-06-07T19:00:00.000Z",
    "dateReserved": "2017-04-19T00:00:00.000Z",
    "dateUpdated": "2024-08-05T16:19:29.459Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2017-7965",
      "date": "2026-09-20",
      "epss": "0.00394",
      "percentile": "0.33442"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:schneider-electric:somachine_hvac:2.1.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0F523B8A-A5DE-40F0-9D17-4DB519107368",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric\u0027s SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller."
        },
        {
          "lang": "es",
          "value": "Existe una vulnerabilidad de desbordamiento de b\u00fafer en el ejecutable del Software de Programaci\u00f3n AlTracePrint.exe, en SoMachine HVAC versi\u00f3n v2.1.0 de Schneider Electric para el controlador Modicon M171/M172."
        }
      ],
      "id": "CVE-2017-7965",
      "lastModified": "2024-11-21T03:33:03.640",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "LOCAL",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.6,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.3,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.3,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2017-06-07T19:29:00.197",
      "references": [
        {
          "source": "cybersecurity@se.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
        },
        {
          "source": "cybersecurity@se.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/98449"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/98449"
        }
      ],
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:schneider-electric:somachine_hvac:2.1.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0F523B8A-A5DE-40F0-9D17-4DB519107368",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric\u0027s SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller."
          },
          {
            "lang": "es",
            "value": "Existe una vulnerabilidad de desbordamiento de b\u00fafer en el ejecutable del Software de Programaci\u00f3n AlTracePrint.exe, en SoMachine HVAC versi\u00f3n v2.1.0 de Schneider Electric para el controlador Modicon M171/M172."
          }
        ],
        "id": "CVE-2017-7965",
        "lastModified": "2026-05-13T00:24:29.033",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.6,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 6.4,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.3,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2017-06-07T19:29:00.197",
        "references": [
          {
            "source": "cybersecurity@se.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
          },
          {
            "source": "cybersecurity@se.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/98449"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/98449"
          }
        ],
        "sourceIdentifier": "cybersecurity@se.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-119"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…