CVE-2018-7239 (GCVE-0-2018-7239)

Vulnerability from cvelistv5 – Published: 2018-03-09 23:00 – Updated: 2024-09-16 23:21
VLAI?
Summary
A DLL hijacking vulnerability exists in Schneider Electric's SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.
Severity ?
No CVSS data available.
CWE
  • DLL Hijacking
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:24:11.489Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
          },
          {
            "name": "103338",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/103338"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SoMove",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-03-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "DLL Hijacking",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-12T16:57:01",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
        },
        {
          "name": "103338",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/103338"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2018-03-01T00:00:00",
          "ID": "CVE-2018-7239",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SoMove",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "DLL Hijacking"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02"
            },
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
            },
            {
              "name": "103338",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/103338"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7239",
    "datePublished": "2018-03-09T23:00:00Z",
    "dateReserved": "2018-02-19T00:00:00",
    "dateUpdated": "2024-09-16T23:21:36.267Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv_lift_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"8F0F8212-5CC6-4EB7-9F37-4587FC849A54\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv12_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"70DDF782-E80B-41A6-88F0-52D3BCCD0BE6\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv212_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"8A9E382F-DBB4-4B24-81C7-EE33B5248935\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv31_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"2429408E-48C9-4F97-A918-4DDECF6A7AB2\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv312_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"44D79762-E0D3-4DB9-8DD8-AE6A93953411\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv32_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"DC70CB2D-2AA8-40EC-97BC-0527D5F100ED\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv320_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.1.6\", \"matchCriteriaId\": \"1D1862C8-5571-4DAC-B9F0-96DC3F2F846F\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv340_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.2.3\", \"matchCriteriaId\": \"CB77B51C-CA0B-4C6E-91D2-41C450C6214E\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv600_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.8.0\", \"matchCriteriaId\": \"FE8C39E7-A682-4453-945F-D1DFC9418A7C\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv61_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"988EB546-BB63-4DEF-800E-5C5A3C796163\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv71_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"848353C2-B49E-4B88-A57A-C783BF47C84C\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv900_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.3.5\", \"matchCriteriaId\": \"3BA8B718-4947-41FE-9DDC-DA3AB85992B3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:somove:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.6.2\", \"matchCriteriaId\": \"AD8AD349-3536-4244-8D10-D860A5A7F1FF\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad de secuestro de DLL en SoMove Software de Schneider Electric y en los componentes de software DTM asociados, en todas las versiones anteriores a la 2.6.2. Esto podr\\u00eda permitir que un atacante ejecute c\\u00f3digo arbitrario.\"}]",
      "id": "CVE-2018-7239",
      "lastModified": "2024-11-21T04:11:51.273",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
      "published": "2018-03-09T23:29:00.967",
      "references": "[{\"url\": \"http://www.securityfocus.com/bid/103338\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/103338\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-426\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-7239\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2018-03-09T23:29:00.967\",\"lastModified\":\"2024-11-21T04:11:51.273\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de secuestro de DLL en SoMove Software de Schneider Electric y en los componentes de software DTM asociados, en todas las versiones anteriores a la 2.6.2. Esto podr\u00eda permitir que un atacante ejecute c\u00f3digo arbitrario.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-426\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv_lift_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"8F0F8212-5CC6-4EB7-9F37-4587FC849A54\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv12_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"70DDF782-E80B-41A6-88F0-52D3BCCD0BE6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv212_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"8A9E382F-DBB4-4B24-81C7-EE33B5248935\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv31_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"2429408E-48C9-4F97-A918-4DDECF6A7AB2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv312_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"44D79762-E0D3-4DB9-8DD8-AE6A93953411\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv32_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"DC70CB2D-2AA8-40EC-97BC-0527D5F100ED\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv320_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.1.6\",\"matchCriteriaId\":\"1D1862C8-5571-4DAC-B9F0-96DC3F2F846F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv340_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.2.3\",\"matchCriteriaId\":\"CB77B51C-CA0B-4C6E-91D2-41C450C6214E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv600_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.8.0\",\"matchCriteriaId\":\"FE8C39E7-A682-4453-945F-D1DFC9418A7C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv61_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"988EB546-BB63-4DEF-800E-5C5A3C796163\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv71_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"848353C2-B49E-4B88-A57A-C783BF47C84C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv900_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.3.5\",\"matchCriteriaId\":\"3BA8B718-4947-41FE-9DDC-DA3AB85992B3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:somove:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.2\",\"matchCriteriaId\":\"AD8AD349-3536-4244-8D10-D860A5A7F1FF\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/103338\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/103338\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…