CVE-2019-3929 (GCVE-0-2019-3929)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:21 – Updated: 2025-10-21 23:45- CWE-79 - OS Command Injection
| URL | Tags |
|---|---|
| https://www.tenable.com/security/research/tra-2019-20 | x_refsource_MISC |
| https://www.exploit-db.com/exploits/46786/ | exploitx_refsource_EXPLOIT-DB |
| http://packetstormsecurity.com/files/152715/Barco… | x_refsource_MISC |
| http://packetstormsecurity.com/files/155948/Barco… | x_refsource_MISC |
| https://www.cisa.gov/known-exploited-vulnerabilit… | government-resource |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Crestron | Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4. |
Affected:
Crestron AM-100 firmware 1.6.0.2
Affected: Crestron AM-101 firmware 2.7.0.1 Affected: Barco wePresent WiPG-1000P firmware 2.3.0.10 Affected: Barco wePresent WiPG-1600W before firmware 2.4.1.19 Affected: Extron ShareLink 200/250 firmware 2.0.3.4 Affected: Teq AV IT WIPS710 firmware 1.1.0.7 Affected: SHARP PN-L703WA firmware 1.4.2.3 Affected: Optoma WPS-Pro firmware 1.0.0.5 Affected: Blackbox HD WPS firmware 1.0.0.5 Affected: InFocus LiteShow3 firmware 1.0.16 Affected: and InFocus LiteShow4 2.0.0.7 |
guessed |
CISA
Known Exploited Vulnerability - GCVE BCP-07 Compliant
Exploited: Yes
Timestamps
Scope
Evidence
Type: Vendor Report
Signal: Successful Exploitation
Confidence: 80%
Source: cisa-kev
Details
| Cwes | CWE-79 |
|---|---|
| Feed | CISA Known Exploited Vulnerabilities Catalog |
| Product | Multiple Products |
| Due Date | 2022-05-06 |
| Date Added | 2022-04-15 |
| Vendorproject | Crestron |
| Vulnerabilityname | Crestron Multiple Products Command Injection Vulnerability |
| Knownransomwarecampaignuse | Unknown |
References
Shadowserver
Known Exploited Vulnerability - GCVE BCP-07 Compliant
Exploited: Yes
Characteristics
Timestamps
Scope
Evidence
Type: Honeypot
Signal: In The Wild Attempts
Confidence: 70%
Source: shadowserver
Details
| 1D | 1 |
|---|---|
| Iot | yes |
| Feed | Shadowserver Foundation honeypot/exploited-vulnerabilities |
| Type | http-scan |
| Class | embedded-system |
| 7D Avg | 1 |
| Vendor | Barco/AWIND |
| 30D Avg | 1 |
| 90D Avg | 2 |
| Product | Barco/AWIND OEM |
| Cisa Kev | yes |
| Connections | 108 |
| Observation Date | 2026-11-14 |
| Vulnerability Class | CVSS |
| Vulnerability Score | 9.8 |
| Vulnerability Severity | Critical |
References
Previdian
Known Exploited Vulnerability - GCVE BCP-07 Compliant
Exploited: Yes
Timestamps
Scope
Evidence
Type: Public Report
Signal: Successful Exploitation
Confidence: 70%
Source: kevintel
Details
| Feed | KEVIntel (kevintel.com) |
|---|---|
| Title | The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W... |
| Vendor | Crestron |
| Product | Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4. |
| Added Date | 2022-04-15T00:00:00.000Z |
| Cvss Score | 9.8 |
| Epss Score | None |
| Cvss Severity | CRITICAL |
| Epss Percentile | None |
| Used In Malware | unknown |
| Ahead Of Cisa Kev | None |
| Not Yet In Cisa Kev | False |
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.549Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-3929",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-06T20:26:27.910638Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2022-04-15",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T23:45:38.287Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929"
}
],
"timeline": [
{
"lang": "en",
"time": "2022-04-15T00:00:00.000Z",
"value": "CVE-2019-3929 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "Crestron AM-100 firmware 1.6.0.2"
},
{
"status": "affected",
"version": "Crestron AM-101 firmware 2.7.0.1"
},
{
"status": "affected",
"version": "Barco wePresent WiPG-1000P firmware 2.3.0.10"
},
{
"status": "affected",
"version": "Barco wePresent WiPG-1600W before firmware 2.4.1.19"
},
{
"status": "affected",
"version": "Extron ShareLink 200/250 firmware 2.0.3.4"
},
{
"status": "affected",
"version": "Teq AV IT WIPS710 firmware 1.1.0.7"
},
{
"status": "affected",
"version": "SHARP PN-L703WA firmware 1.4.2.3"
},
{
"status": "affected",
"version": "Optoma WPS-Pro firmware 1.0.0.5"
},
{
"status": "affected",
"version": "Blackbox HD WPS firmware 1.0.0.5"
},
{
"status": "affected",
"version": "InFocus LiteShow3 firmware 1.0.16"
},
{
"status": "affected",
"version": "and InFocus LiteShow4 2.0.0.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-14T17:06:03.000Z",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3929",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.",
"version": {
"version_data": [
{
"version_value": "Crestron AM-100 firmware 1.6.0.2"
},
{
"version_value": "Crestron AM-101 firmware 2.7.0.1"
},
{
"version_value": "Barco wePresent WiPG-1000P firmware 2.3.0.10"
},
{
"version_value": "Barco wePresent WiPG-1600W before firmware 2.4.1.19"
},
{
"version_value": "Extron ShareLink 200/250 firmware 2.0.3.4"
},
{
"version_value": "Teq AV IT WIPS710 firmware 1.1.0.7"
},
{
"version_value": "SHARP PN-L703WA firmware 1.4.2.3"
},
{
"version_value": "Optoma WPS-Pro firmware 1.0.0.5"
},
{
"version_value": "Blackbox HD WPS firmware 1.0.0.5"
},
{
"version_value": "InFocus LiteShow3 firmware 1.0.16"
},
{
"version_value": "and InFocus LiteShow4 2.0.0.7"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 OS Command Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"name": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"name": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3929",
"datePublished": "2019-04-30T20:21:09.000Z",
"dateReserved": "2019-01-03T00:00:00.000Z",
"dateUpdated": "2025-10-21T23:45:38.287Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"cisa_known_exploited": {
"cveID": "CVE-2019-3929",
"cwes": [
"CWE-79"
],
"dateAdded": "2022-04-15",
"dueDate": "2022-05-06",
"forensicTriage": "No",
"knownRansomwareCampaignUse": "Unknown",
"notes": "https://nvd.nist.gov/vuln/detail/CVE-2019-3929",
"product": "Multiple Products",
"requiredAction": "Apply updates per vendor instructions.",
"shortDescription": "Multiple Crestron products are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.",
"vendorProject": "Crestron",
"vulnerabilityName": "Crestron Multiple Products Command Injection Vulnerability"
},
"epss": {
"cve": "CVE-2019-3929",
"date": "2026-11-15",
"epss": "0.98952",
"percentile": "0.99929"
},
"fkie_nvd": {
"cisaActionDue": "2022-05-06",
"cisaExploitAdd": "2022-04-15",
"cisaRequiredAction": "Apply updates per vendor instructions.",
"cisaVulnerabilityName": "Crestron Multiple Products Command Injection Vulnerability",
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:crestron:am-100_firmware:1.6.0.2:*:*:*:*:*:*:*",
"matchCriteriaId": "913135BE-8FB4-40BA-85D8-AD0F824493C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:crestron:am-100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "081E2B1B-027D-4846-8C61-54CE2D668CD0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:crestron:am-101_firmware:2.7.0.2:*:*:*:*:*:*:*",
"matchCriteriaId": "6AC584E7-9159-48E8-B499-F5CA68663503",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:crestron:am-101:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D0AB0523-6EFF-4C78-A8BA-B2764DBB04D0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:barco:wepresent_wipg-1000p_firmware:2.3.0.10:*:*:*:*:*:*:*",
"matchCriteriaId": "4102ECBE-C362-4D67-A8B8-E0C796991A05",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:barco:wepresent_wipg-1000p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4CA49409-DD7A-443C-9C64-F7FC02AD572F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CC11E306-2039-4981-B0DE-F0E086E82A99",
"versionEndExcluding": "2.4.1.19",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:barco:wepresent_wipg-1600w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E6EDF943-F79F-4729-A15C-BEDFDAC42EA3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:extron:sharelink_200_firmware:2.0.3.4:*:*:*:*:*:*:*",
"matchCriteriaId": "A2A958C1-D420-4686-B16A-9F894D9D546B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:extron:sharelink_200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9052908E-4A0A-4462-9054-FF8B81BE61AD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:extron:sharelink_250_firmware:2.0.3.4:*:*:*:*:*:*:*",
"matchCriteriaId": "4452FE8E-2FF1-4920-BE15-EDB36865E436",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:extron:sharelink_250:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6D0429EC-69E4-40DF-8F58-92C14B1EE30F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:teqavit:wips710_firmware:1.1.0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "30DE4653-931B-4EE4-997C-EDE3B4FD1103",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:teqavit:wips710:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4C065DAA-CCAD-4551-A6D3-61A714EBEC2A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sharp:pn-l703wa_firmware:1.4.2.3:*:*:*:*:*:*:*",
"matchCriteriaId": "1B378214-4F0E-4365-92B4-A1C1CA1BF8E9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sharp:pn-l703wa:-:*:*:*:*:*:*:*",
"matchCriteriaId": "515FE3BB-C5C9-496C-A002-E5687D5D2B00",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:optoma:wps-pro_firmware:1.0.0.5:*:*:*:*:*:*:*",
"matchCriteriaId": "B85EAE85-7C54-4B93-96BA-72FCB1CFA94F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:optoma:wps-pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2033CAD9-390C-4AA4-A05E-951849AB16E8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:blackbox:hd_wireless_presentation_system_firmware:1.0.0.5:*:*:*:*:*:*:*",
"matchCriteriaId": "2143F71D-47D5-4630-B1CF-74824682523C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:blackbox:hd_wireless_presentation_system:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5722F58-47BA-4430-8F92-FA56348FD4A9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:infocus:liteshow3_firmware:1.0.16:*:*:*:*:*:*:*",
"matchCriteriaId": "A31899CB-CC41-446A-AB84-40D2BDED1F30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:infocus:liteshow3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7E81DF5B-9FD1-44E7-B23D-639ACAD4EED0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:infocus:liteshow4_firmware:2.0.0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "D361E8D9-377E-4DBB-BFAC-35CB4333A6EB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:infocus:liteshow4:-:*:*:*:*:*:*:*",
"matchCriteriaId": "76B7C16D-C7D8-4502-B466-1D6A0183527A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"descriptions": [
{
"lang": "en",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
},
{
"lang": "es",
"value": "El firmware Crestron AM-100 versi\u00f3n 1.6.0.2, el firmware Crestron AM-101 versi\u00f3n 2.7.0.1, Barco wePresent WiPG-1000P firmware versi\u00f3n 2.3.0.10, Barco wePresent WiPG-1600W antes del firmware versi\u00f3n 2.4.1.19, Extron ShareLink 200/250 firmware versi\u00f3n 2.0.3.4, Teq AV IT WIPS710 firmware versi\u00f3n 1.1.0.7, SHARP PN-L703WA firmware versi\u00f3n 1.4.2.3, Optoma WPS-Pro firmware versi\u00f3n 1.0.0.5, Blackbox HD WPS firmware versi\u00f3n 1.0.0.5, InFocus LiteShow3 firmware versi\u00f3n 1.0.16 e InFocus LiteShow4 versi\u00f3n 2.0.0.7 son vulnerables para ordenar la inyecci\u00f3n por medio del endpoint HTTP file_transfer.cgi. Un atacante remoto no identificado puede usar esta vulnerabilidad para ejecutar comandos del sistema operativo como root."
}
],
"id": "CVE-2019-3929",
"lastModified": "2024-11-21T04:42:53.067",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-04-30T21:29:00.713",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"source": "vulnreport@tenable.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
},
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "vulnreport@tenable.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"nvd": {
"cve": {
"cisaActionDue": "2022-05-06",
"cisaExploitAdd": "2022-04-15",
"cisaRequiredAction": "Apply updates per vendor instructions.",
"cisaVulnerabilityName": "Crestron Multiple Products Command Injection Vulnerability",
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:crestron:am-100_firmware:1.6.0.2:*:*:*:*:*:*:*",
"matchCriteriaId": "913135BE-8FB4-40BA-85D8-AD0F824493C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:crestron:am-100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "081E2B1B-027D-4846-8C61-54CE2D668CD0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:crestron:am-101_firmware:2.7.0.2:*:*:*:*:*:*:*",
"matchCriteriaId": "6AC584E7-9159-48E8-B499-F5CA68663503",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:crestron:am-101:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D0AB0523-6EFF-4C78-A8BA-B2764DBB04D0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:barco:wepresent_wipg-1000p_firmware:2.3.0.10:*:*:*:*:*:*:*",
"matchCriteriaId": "4102ECBE-C362-4D67-A8B8-E0C796991A05",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:barco:wepresent_wipg-1000p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4CA49409-DD7A-443C-9C64-F7FC02AD572F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CC11E306-2039-4981-B0DE-F0E086E82A99",
"versionEndExcluding": "2.4.1.19",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:barco:wepresent_wipg-1600w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E6EDF943-F79F-4729-A15C-BEDFDAC42EA3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:extron:sharelink_200_firmware:2.0.3.4:*:*:*:*:*:*:*",
"matchCriteriaId": "A2A958C1-D420-4686-B16A-9F894D9D546B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:extron:sharelink_200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9052908E-4A0A-4462-9054-FF8B81BE61AD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:extron:sharelink_250_firmware:2.0.3.4:*:*:*:*:*:*:*",
"matchCriteriaId": "4452FE8E-2FF1-4920-BE15-EDB36865E436",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:extron:sharelink_250:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6D0429EC-69E4-40DF-8F58-92C14B1EE30F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:teqavit:wips710_firmware:1.1.0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "30DE4653-931B-4EE4-997C-EDE3B4FD1103",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:teqavit:wips710:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4C065DAA-CCAD-4551-A6D3-61A714EBEC2A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sharp:pn-l703wa_firmware:1.4.2.3:*:*:*:*:*:*:*",
"matchCriteriaId": "1B378214-4F0E-4365-92B4-A1C1CA1BF8E9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sharp:pn-l703wa:-:*:*:*:*:*:*:*",
"matchCriteriaId": "515FE3BB-C5C9-496C-A002-E5687D5D2B00",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:optoma:wps-pro_firmware:1.0.0.5:*:*:*:*:*:*:*",
"matchCriteriaId": "B85EAE85-7C54-4B93-96BA-72FCB1CFA94F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:optoma:wps-pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2033CAD9-390C-4AA4-A05E-951849AB16E8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:blackbox:hd_wireless_presentation_system_firmware:1.0.0.5:*:*:*:*:*:*:*",
"matchCriteriaId": "2143F71D-47D5-4630-B1CF-74824682523C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:blackbox:hd_wireless_presentation_system:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5722F58-47BA-4430-8F92-FA56348FD4A9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:infocus:liteshow3_firmware:1.0.16:*:*:*:*:*:*:*",
"matchCriteriaId": "A31899CB-CC41-446A-AB84-40D2BDED1F30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:infocus:liteshow3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7E81DF5B-9FD1-44E7-B23D-639ACAD4EED0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:infocus:liteshow4_firmware:2.0.0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "D361E8D9-377E-4DBB-BFAC-35CB4333A6EB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:infocus:liteshow4:-:*:*:*:*:*:*:*",
"matchCriteriaId": "76B7C16D-C7D8-4502-B466-1D6A0183527A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
},
{
"lang": "es",
"value": "El firmware Crestron AM-100 versi\u00f3n 1.6.0.2, el firmware Crestron AM-101 versi\u00f3n 2.7.0.1, Barco wePresent WiPG-1000P firmware versi\u00f3n 2.3.0.10, Barco wePresent WiPG-1600W antes del firmware versi\u00f3n 2.4.1.19, Extron ShareLink 200/250 firmware versi\u00f3n 2.0.3.4, Teq AV IT WIPS710 firmware versi\u00f3n 1.1.0.7, SHARP PN-L703WA firmware versi\u00f3n 1.4.2.3, Optoma WPS-Pro firmware versi\u00f3n 1.0.0.5, Blackbox HD WPS firmware versi\u00f3n 1.0.0.5, InFocus LiteShow3 firmware versi\u00f3n 1.0.16 e InFocus LiteShow4 versi\u00f3n 2.0.0.7 son vulnerables para ordenar la inyecci\u00f3n por medio del endpoint HTTP file_transfer.cgi. Un atacante remoto no identificado puede usar esta vulnerabilidad para ejecutar comandos del sistema operativo como root."
}
],
"id": "CVE-2019-3929",
"lastModified": "2025-11-03T18:59:33.857",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2019-04-30T21:29:00.713",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"source": "vulnreport@tenable.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
},
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"tags": [
"US Government Resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "vulnreport@tenable.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.549Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-3929",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-06T20:26:27.910638Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2022-04-15",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T20:25:53.616Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929"
}
],
"timeline": [
{
"lang": "en",
"time": "2022-04-15T00:00:00.000Z",
"value": "CVE-2019-3929 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "Crestron AM-100 firmware 1.6.0.2"
},
{
"status": "affected",
"version": "Crestron AM-101 firmware 2.7.0.1"
},
{
"status": "affected",
"version": "Barco wePresent WiPG-1000P firmware 2.3.0.10"
},
{
"status": "affected",
"version": "Barco wePresent WiPG-1600W before firmware 2.4.1.19"
},
{
"status": "affected",
"version": "Extron ShareLink 200/250 firmware 2.0.3.4"
},
{
"status": "affected",
"version": "Teq AV IT WIPS710 firmware 1.1.0.7"
},
{
"status": "affected",
"version": "SHARP PN-L703WA firmware 1.4.2.3"
},
{
"status": "affected",
"version": "Optoma WPS-Pro firmware 1.0.0.5"
},
{
"status": "affected",
"version": "Blackbox HD WPS firmware 1.0.0.5"
},
{
"status": "affected",
"version": "InFocus LiteShow3 firmware 1.0.16"
},
{
"status": "affected",
"version": "and InFocus LiteShow4 2.0.0.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-14T17:06:03.000Z",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3929",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.",
"version": {
"version_data": [
{
"version_value": "Crestron AM-100 firmware 1.6.0.2"
},
{
"version_value": "Crestron AM-101 firmware 2.7.0.1"
},
{
"version_value": "Barco wePresent WiPG-1000P firmware 2.3.0.10"
},
{
"version_value": "Barco wePresent WiPG-1600W before firmware 2.4.1.19"
},
{
"version_value": "Extron ShareLink 200/250 firmware 2.0.3.4"
},
{
"version_value": "Teq AV IT WIPS710 firmware 1.1.0.7"
},
{
"version_value": "SHARP PN-L703WA firmware 1.4.2.3"
},
{
"version_value": "Optoma WPS-Pro firmware 1.0.0.5"
},
{
"version_value": "Blackbox HD WPS firmware 1.0.0.5"
},
{
"version_value": "InFocus LiteShow3 firmware 1.0.16"
},
{
"version_value": "and InFocus LiteShow4 2.0.0.7"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 OS Command Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"name": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"name": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3929",
"datePublished": "2019-04-30T20:21:09.000Z",
"dateReserved": "2019-01-03T00:00:00.000Z",
"dateUpdated": "2025-10-21T23:45:38.287Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.