CVE-2019-6567
Vulnerability from cvelistv5
Published
2019-06-12 13:47
Modified
2024-08-04 20:23
Severity ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:22.108Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.2.4"
            }
          ]
        },
        {
          "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X-414-3E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions \u003c V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-257",
              "description": "CWE-257: Storing Passwords in a Recoverable Format",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-09T15:38:17",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-6567",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All Versions \u003c V5.2.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.5.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X-414-3E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions \u003c V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-257: Storing Passwords in a Recoverable Format"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-6567",
    "datePublished": "2019-06-12T13:47:56",
    "dateReserved": "2019-01-22T00:00:00",
    "dateUpdated": "2024-08-04T20:23:22.108Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-6567\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2019-06-12T14:29:04.820\",\"lastModified\":\"2021-02-09T18:15:16.183\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions \u003c V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en la familia de switches SCALANCE X-200 (incluidas las variantes SIPLUS NET) (Todas las versiones anteriores a V5.2.4), familia de switches SCALANCE X-200IRT (incluidas las variantes SIPLUS NET) (Todas las versiones anteriores a V5.5.0), familia de switches SCALANCE X-300 (incluyendo X408 y las variantes SIPLUS NET) (Todas las versiones anteriores a V4.1.3), SCALANCE X-414-3E (Todas las versiones). Los dispositivos afectados almacenan contrase\u00f1as en un formato recuperable. Un atacante puede extraer y recuperar contrase\u00f1as de dispositivos desde la configuraci\u00f3n del dispositivo. La explotaci\u00f3n exitosa requiere acceso a una copia de seguridad de la configuraci\u00f3n del dispositivo e impacta la confidencialidad de las contrase\u00f1as almacenadas. En el momento de la publicaci\u00f3n del aviso no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:N/A:N\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":2.1},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-522\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-257\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x-200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6FEF9F9F-4066-483B-BF95-3BA5625284DF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x-200_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.4\",\"matchCriteriaId\":\"443B5E7B-A491-4883-9853-A88D3B24E220\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"94C7BE35-D3A6-488C-BB3D-D17D65DF4B80\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"602CAF2E-2276-455C-82E5-A05BBFC198C5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B2D0AB50-6F0B-4232-8C8E-1647410D362D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3F2C50BB-CC63-40BE-A5F0-0F0C342586CA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x-414-3e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CE7762EE-1253-4A4B-81CF-1A6423135AB6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x-414-3e_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C9B3E06E-8822-406C-907A-40AE328B311C\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.