Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2019-8261 (GCVE-0-2019-8261)
Vulnerability from cvelistv5 – Published: 2019-03-05 15:00 – Updated: 2024-09-17 03:12
VLAI
EPSS
Summary
UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC code inside client CoRRE decoder, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.
Severity
No CVSS data available.
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://ics-cert.kaspersky.com/advisories/klcert-… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | x_refsource_MISC |
Date Public
2019-03-01 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.573Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-007-ultravnc-out-of-bound-read/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "UltraVNC",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC code inside client CoRRE decoder, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-28T12:00:18.000Z",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-007-ultravnc-out-of-bound-read/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8261",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "UltraVNC"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC code inside client CoRRE decoder, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-007-ultravnc-out-of-bound-read/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-007-ultravnc-out-of-bound-read/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8261",
"datePublished": "2019-03-05T15:00:00.000Z",
"dateReserved": "2019-02-12T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:12:34.003Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2019-8261",
"date": "2026-05-27",
"epss": "0.00985",
"percentile": "0.77072"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:uvnc:ultravnc:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.2.2.3\", \"matchCriteriaId\": \"555D034F-3D64-4ED1-9B63-F8D59199E99C\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC code inside client CoRRE decoder, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.\"}, {\"lang\": \"es\", \"value\": \"UltraVNC, en su revisi\\u00f3n 1199, contiene una vulnerabilidad de lectura fuera de l\\u00edmites en el c\\u00f3digo VNC dentro del decodificador del cliente CoRRE, provocado por el desbordamiento de multiplicaciones. Este ataque parece ser explotable mediante la conectividad de red. Esto se ha solucionado en la revisi\\u00f3n 1200.\"}]",
"id": "CVE-2019-8261",
"lastModified": "2024-11-21T04:49:35.937",
"metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 7.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2019-03-05T15:29:00.443",
"references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf\", \"source\": \"vulnerability@kaspersky.com\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf\", \"source\": \"vulnerability@kaspersky.com\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf\", \"source\": \"vulnerability@kaspersky.com\"}, {\"url\": \"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-007-ultravnc-out-of-bound-read/\", \"source\": \"vulnerability@kaspersky.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11\", \"source\": \"vulnerability@kaspersky.com\"}, {\"url\": \"https://www.us-cert.gov/ics/advisories/icsa-20-161-06\", \"source\": \"vulnerability@kaspersky.com\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-007-ultravnc-out-of-bound-read/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://www.us-cert.gov/ics/advisories/icsa-20-161-06\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "vulnerability@kaspersky.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"vulnerability@kaspersky.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-125\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-125\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-8261\",\"sourceIdentifier\":\"vulnerability@kaspersky.com\",\"published\":\"2019-03-05T15:29:00.443\",\"lastModified\":\"2024-11-21T04:49:35.937\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC code inside client CoRRE decoder, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.\"},{\"lang\":\"es\",\"value\":\"UltraVNC, en su revisi\u00f3n 1199, contiene una vulnerabilidad de lectura fuera de l\u00edmites en el c\u00f3digo VNC dentro del decodificador del cliente CoRRE, provocado por el desbordamiento de multiplicaciones. Este ataque parece ser explotable mediante la conectividad de red. Esto se ha solucionado en la revisi\u00f3n 1200.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"vulnerability@kaspersky.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:uvnc:ultravnc:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.2.2.3\",\"matchCriteriaId\":\"555D034F-3D64-4ED1-9B63-F8D59199E99C\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf\",\"source\":\"vulnerability@kaspersky.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf\",\"source\":\"vulnerability@kaspersky.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf\",\"source\":\"vulnerability@kaspersky.com\"},{\"url\":\"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-007-ultravnc-out-of-bound-read/\",\"source\":\"vulnerability@kaspersky.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11\",\"source\":\"vulnerability@kaspersky.com\"},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-161-06\",\"source\":\"vulnerability@kaspersky.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-007-ultravnc-out-of-bound-read/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-161-06\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
}
}
ICSA-20-161-06
Vulnerability from csaf_cisa - Published: 2020-06-09 00:00 - Updated: 2020-06-09 00:00Summary
Siemens SINUMERIK
Notes
CISA Disclaimer: This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice: All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation: Successful exploitation of these vulnerabilities could allow remote code execution, information disclosure, and denial-of-service attacks under certain conditions.
Critical infrastructure sectors: Chemical, Energy, Food and Agriculture, Water and Wastewater Systems
Countries/areas deployed: Worldwide
Company headquarters location: Germany
Recommended Practices: CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Additional Resources: Listed vulnerabilities are part of a Kaspersky report. See VNC
vulnerability research for related security advisories and additional
information on the vulnerabilites.
For further inquiries on security vulnerabilities in Siemens products and
solutions, please contact the Siemens ProductCERT:
https://www.siemens.com/cert/advisories
Additional Resources: Listed vulnerabilities are part of a Kaspersky report. See VNC vulnerability research for related security advisories and additional information on the vulnerabilites. For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Exploitability: No known public exploits specifically target these vulnerabilities.
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
CWE-665
- Improper Initialization
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
CWE-121
- Stack-based Buffer Overflow
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
CWE-125
- Out-of-bounds Read
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
CWE-121
- Stack-based Buffer Overflow
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
CWE-125
- Out-of-bounds Read
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
CWE-121
- Stack-based Buffer Overflow
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
CWE-665
- Improper Initialization
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
3 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINUMERIK Access MyMachine /P2P: All versions < V4.8
Siemens / SINUMERIK Access MyMachine /P2P
|
All versions < V4.8 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win10 software /IPC: All versions < V14.00
Siemens / SINUMERIK PCU base Win10 software /IPC
|
All versions < V14.00 |
Vendor Fix
Mitigation
|
|
|
SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4
Siemens / SINUMERIK PCU base Win7 software /IPC
|
All versions < V12.01 HF4 |
Vendor Fix
Mitigation
|
References
32 references
Acknowledgments
Siemens
{
"document": {
"acknowledgments": [
{
"organization": "Siemens",
"summary": "reporting these vulnerabilities to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could allow remote code execution, information disclosure, and denial-of-service attacks under certain conditions.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Chemical, Energy, Food and Agriculture, Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Listed vulnerabilities are part of a Kaspersky report. See VNC\nvulnerability research for related security advisories and additional\ninformation on the vulnerabilites.\n\nFor further inquiries on security vulnerabilities in Siemens products and \nsolutions, please contact the Siemens ProductCERT:\n\nhttps://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "general",
"text": "Listed vulnerabilities are part of a Kaspersky report. See VNC vulnerability research for related security advisories and additional information on the vulnerabilites. For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-20-161-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-161-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-20-161-06 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-161-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "SSA-496604: SSA-927095: UltraVNC Vulnerabilities in SINUMERIK Products - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/SSA-927095.txt"
}
],
"title": "Siemens SINUMERIK",
"tracking": {
"current_release_date": "2020-06-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-20-161-06",
"initial_release_date": "2020-06-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2020-06-09T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-20-161-06 Siemens SINUMERIK"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V4.8",
"product": {
"name": "SINUMERIK Access MyMachine /P2P: All versions \u003c V4.8",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SINUMERIK Access MyMachine /P2P"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V14.00",
"product": {
"name": "SINUMERIK PCU base Win10 software /IPC: All versions \u003c V14.00",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SINUMERIK PCU base Win10 software /IPC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V12.01 HF4",
"product": {
"name": "SINUMERIK PCU base Win7 software /IPC: All versions \u003c V12.01 HF4",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "SINUMERIK PCU base Win7 software /IPC"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2018-15361",
"cwe": {
"id": "CWE-124",
"name": "Buffer Underwrite (\u0027Buffer Underflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1198 has a buffer underflow vulnerability in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1199.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-15361"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8258",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1198 has a heap buffer overflow vulnerability in VNC client code which results code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1199.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8258"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8259",
"cwe": {
"id": "CWE-665",
"name": "Improper Initialization"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1198 contains multiple memory leaks in VNC client code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1199.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8259"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8260",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC client RRE decoder code, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8260"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8261",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC code inside client CoRRE decoder, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8261"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8262",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which results in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8262"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8263",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1205 has stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8263"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8264",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside Ultra2 decoder, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8264"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8265",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of SETPIXELS macro in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1208.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8265"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8266",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of ClientConnection::Copybuffer function in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. User interaction is required to trigger these vulnerabilities. These vulnerabilities have been fixed in revision 1208.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8266"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8267",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1207 has out-of-bounds read vulnerability in VNC client code inside TextChat module, which results in a denial of service (DoS) condition. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1208.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8267"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8268",
"cwe": {
"id": "CWE-193",
"name": "Off-by-one Error"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8268"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8269",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8269"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8270",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1210 has out-of-bounds read vulnerability in VNC client code inside Ultra decoder, which results in a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1211.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8270"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8271",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer handler, which can potentially result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8271"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8272",
"cwe": {
"id": "CWE-193",
"name": "Off-by-one Error"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has multiple off-by-one vulnerabilities in VNC server code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8272"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8273",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer request handler, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8273"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8274",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8274"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8275",
"cwe": {
"id": "CWE-170",
"name": "Improper Null Termination"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8275"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8276",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8276"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8277",
"cwe": {
"id": "CWE-665",
"name": "Improper Initialization"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 contains multiple memory leaks in VNC server code, which allows an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8277"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8280",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside RAW decoder, which can potentially result code execution. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8280"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
}
]
}
ICSA-21-131-04
Vulnerability from csaf_cisa - Published: 2021-05-11 00:00 - Updated: 2025-05-06 06:00Summary
Siemens SINAMICS Medium Voltage Products Remote Access (Update B)
Notes
Summary: SINAMICS medium voltage products, with Sm@rtServer enabled on SIMATIC comfort HMI Panels, are affected by multiple vulnerabilities that could allow an attacker, under certain conditions, to gain full remote access to the HMI. Note that by default Sm@rtServer is disabled, but it can be enabled by the system integrator on request.
Siemens has released updates for the affected products, and recommends to update them to the latest version.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice: All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer: This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors: Multiple
Countries/areas deployed: Worldwide
Company headquarters location: Germany
Recommended Practices: CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices: Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices: When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CWE-665
- Improper Initialization
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
CWE-121
- Stack-based Buffer Overflow
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
CWE-665
- Improper Initialization
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
CWE-770
- Allocation of Resources Without Limits or Throttling
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
CWE-400
- Uncontrolled Resource Consumption
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
CWE-401
- Missing Release of Memory after Effective Lifetime
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
References
25 references
Acknowledgments
Siemens ProductCERT
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "SINAMICS medium voltage products, with Sm@rtServer enabled on SIMATIC comfort HMI Panels, are affected by multiple vulnerabilities that could allow an attacker, under certain conditions, to gain full remote access to the HMI. Note that by default Sm@rtServer is disabled, but it can be enabled by the system integrator on request.\n\nSiemens has released updates for the affected products, and recommends to update them to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-286838: Multiple Vulnerabilities in SINAMICS Medium Voltage Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-286838.json"
},
{
"category": "self",
"summary": "SSA-286838: Multiple Vulnerabilities in SINAMICS Medium Voltage Products - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-286838.txt"
},
{
"category": "self",
"summary": "SSA-286838: Multiple Vulnerabilities in SINAMICS Medium Voltage Products - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-131-04 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-131-04.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-131-04 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-131-04"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SINAMICS Medium Voltage Products Remote Access (Update B)",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-131-04",
"initial_release_date": "2021-05-11T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-05-11T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2021-08-10T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Updated information for SINAMICS SL150, SINAMICS SM150 and SINAMICS SM150i"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "3",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS GH150",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SINAMICS GH150"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS GL150 (with option X30)",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SINAMICS GL150 (with option X30)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS GM150 (with option X30)",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "SINAMICS GM150 (with option X30)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS SH150",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "SINAMICS SH150"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS SL150",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "SINAMICS SL150"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS SM120",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "SINAMICS SM120"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS SM150",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "SINAMICS SM150"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS SM150i",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "SINAMICS SM150i"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-8259",
"cwe": {
"id": "CWE-665",
"name": "Improper Initialization"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1198 contains multiple memory leaks in VNC client code, which could allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1199.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
"references": [
{
"summary": "CVE-2019-8259 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8259.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0007"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"title": "CVE-2019-8259"
},
{
"cve": "CVE-2019-8260",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC client RRE decoder code, caused by multiplication overflow. This vulnerability appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
"references": [
{
"summary": "CVE-2019-8260 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8260.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0007"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"title": "CVE-2019-8260"
},
{
"cve": "CVE-2019-8261",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC code inside client CoRRE decoder, caused by multiplication overflow. This vulnerability appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
"references": [
{
"summary": "CVE-2019-8261 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8261.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0007"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"title": "CVE-2019-8261"
},
{
"cve": "CVE-2019-8262",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which could result in code execution. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
"references": [
{
"summary": "CVE-2019-8262 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8262.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0007"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"title": "CVE-2019-8262"
},
{
"cve": "CVE-2019-8263",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1205 has a stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which could lead to a denial of service (DoS) condition. This vulnerability appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
"references": [
{
"summary": "CVE-2019-8263 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8263.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0007"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"title": "CVE-2019-8263"
},
{
"cve": "CVE-2019-8264",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has a out-of-bounds access vulnerability in VNC client inside Ultra2 decoder, which can potentially result in code execution. This vulnerability appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
"references": [
{
"summary": "CVE-2019-8264 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8264.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0007"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"title": "CVE-2019-8264"
},
{
"cve": "CVE-2019-8265",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of SETPIXELS macro in VNC client code, which can potentially result in code execution. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1208.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
"references": [
{
"summary": "CVE-2019-8265 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8265.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0007"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"title": "CVE-2019-8265"
},
{
"cve": "CVE-2019-8275",
"cwe": {
"id": "CWE-170",
"name": "Improper Null Termination"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which could result in out-of-bound data being accessed by remote users. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
"references": [
{
"summary": "CVE-2019-8275 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8275.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0007"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"title": "CVE-2019-8275"
},
{
"cve": "CVE-2019-8277",
"cwe": {
"id": "CWE-665",
"name": "Improper Initialization"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 contains multiple memory leaks in VNC server code, which could allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
"references": [
{
"summary": "CVE-2019-8277 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8277.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0007"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"title": "CVE-2019-8277"
},
{
"cve": "CVE-2019-8280",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside RAW decoder, which can potentially result in code execution. This vulnerability appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
"references": [
{
"summary": "CVE-2019-8280 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8280.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0007"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"title": "CVE-2019-8280"
},
{
"cve": "CVE-2021-27383",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
"references": [
{
"summary": "CVE-2021-27383 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27383.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0007"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"title": "CVE-2021-27383"
},
{
"cve": "CVE-2021-27384",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
"references": [
{
"summary": "CVE-2021-27384 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27384.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0007"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"title": "CVE-2021-27384"
},
{
"cve": "CVE-2021-27385",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
"references": [
{
"summary": "CVE-2021-27385 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27385.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0007"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"title": "CVE-2021-27385"
},
{
"cve": "CVE-2021-27386",
"cwe": {
"id": "CWE-401",
"name": "Missing Release of Memory after Effective Lifetime"
},
"notes": [
{
"category": "summary",
"text": "SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
"references": [
{
"summary": "CVE-2021-27386 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27386.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0007"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008"
]
}
],
"title": "CVE-2021-27386"
}
]
}
ICSA-21-131-11
Vulnerability from csaf_cisa - Published: 2021-05-11 00:00 - Updated: 2025-05-06 06:00Summary
Siemens SIMATIC UltraVNC HMI WinCC Products
Notes
Summary: UltraVNC vulnerabilities in the affected products listed below could allow remote code execution, information disclosure and Denial-of-Service attacks under certain conditions.
Siemens has released updates for the affected products and recommends to update to the latest versions.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice: All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer: This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors: Multiple
Countries/areas deployed: Worldwide
Company headquarters location: Germany
Recommended Practices: CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices: Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices: When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CWE-665
- Improper Initialization
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
CWE-121
- Stack-based Buffer Overflow
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
CWE-665
- Improper Initialization
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
<V16_Update_4 |
Vendor Fix
fix
Mitigation
|
References
61 references
Acknowledgments
Siemens ProductCERT
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "UltraVNC vulnerabilities in the affected products listed below could allow remote code execution, information disclosure and Denial-of-Service attacks under certain conditions.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-940818: UltraVNC Vulnerabilities in SIMATIC HMIs/WinCC Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-940818.json"
},
{
"category": "self",
"summary": "SSA-940818: UltraVNC Vulnerabilities in SIMATIC HMIs/WinCC Products - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-940818.txt"
},
{
"category": "self",
"summary": "SSA-940818: UltraVNC Vulnerabilities in SIMATIC HMIs/WinCC Products - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-131-11 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-131-11.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-131-11 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-131-11"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SIMATIC UltraVNC HMI WinCC Products",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-131-11",
"initial_release_date": "2021-05-11T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-05-11T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "2",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV16_Update_4",
"product": {
"name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV16_Update_4",
"product": {
"name": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV16_Update_4",
"product": {
"name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV16_Update_4",
"product": {
"name": "SIMATIC WinCC Runtime Advanced",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Advanced"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-8259",
"cwe": {
"id": "CWE-665",
"name": "Improper Initialization"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1198 contains multiple memory leaks in VNC client code, which could allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1199.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"references": [
{
"summary": "CVE-2019-8259 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8259 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8259 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8259 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8259 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8259.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"title": "CVE-2019-8259"
},
{
"cve": "CVE-2019-8260",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC client RRE decoder code, caused by multiplication overflow. This vulnerability appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"references": [
{
"summary": "CVE-2019-8260 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8260 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8260 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8260 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8260 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8260.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"title": "CVE-2019-8260"
},
{
"cve": "CVE-2019-8261",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC code inside client CoRRE decoder, caused by multiplication overflow. This vulnerability appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"references": [
{
"summary": "CVE-2019-8261 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8261 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8261 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8261 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8261 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8261.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"title": "CVE-2019-8261"
},
{
"cve": "CVE-2019-8262",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which could result in code execution. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"references": [
{
"summary": "CVE-2019-8262 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8262 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8262 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8262 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8262 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8262.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"title": "CVE-2019-8262"
},
{
"cve": "CVE-2019-8263",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1205 has a stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which could lead to a denial of service (DoS) condition. This vulnerability appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"references": [
{
"summary": "CVE-2019-8263 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8263 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8263 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8263 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8263 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8263.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"title": "CVE-2019-8263"
},
{
"cve": "CVE-2019-8264",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has a out-of-bounds access vulnerability in VNC client inside Ultra2 decoder, which can potentially result in code execution. This vulnerability appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"references": [
{
"summary": "CVE-2019-8264 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8264 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8264 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8264 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8264 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8264.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"title": "CVE-2019-8264"
},
{
"cve": "CVE-2019-8265",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of SETPIXELS macro in VNC client code, which can potentially result in code execution. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1208.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"references": [
{
"summary": "CVE-2019-8265 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8265 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8265 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8265 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8265 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8265.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"title": "CVE-2019-8265"
},
{
"cve": "CVE-2019-8275",
"cwe": {
"id": "CWE-170",
"name": "Improper Null Termination"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which could result in out-of-bound data being accessed by remote users. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"references": [
{
"summary": "CVE-2019-8275 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8275 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8275 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8275 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8275 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8275.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"title": "CVE-2019-8275"
},
{
"cve": "CVE-2019-8277",
"cwe": {
"id": "CWE-665",
"name": "Improper Initialization"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 contains multiple memory leaks in VNC server code, which could allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"references": [
{
"summary": "CVE-2019-8277 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8277 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8277 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8277 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8277 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8277.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"title": "CVE-2019-8277"
},
{
"cve": "CVE-2019-8280",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside RAW decoder, which can potentially result in code execution. This vulnerability appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"references": [
{
"summary": "CVE-2019-8280 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8280 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8280 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8280 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8280 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8280.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"title": "CVE-2019-8280"
}
]
}
SSA-286838
Vulnerability from csaf_siemens - Published: 2021-05-11 00:00 - Updated: 2021-08-10 00:00Summary
SSA-286838: Multiple Vulnerabilities in SINAMICS Medium Voltage Products
Notes
Summary: SINAMICS medium voltage products, with Sm@rtServer enabled on SIMATIC comfort HMI Panels, are affected by multiple vulnerabilities that could allow an attacker, under certain conditions, to gain full remote access to the HMI. Note that by default Sm@rtServer is disabled, but it can be enabled by the system integrator on request.
Siemens has released updates for the affected products, and recommends to update them to the latest version.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
CWE-665
- Improper Initialization
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
CWE-121
- Stack-based Buffer Overflow
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
CWE-665
- Improper Initialization
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
CWE-770
- Allocation of Resources Without Limits or Throttling
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
9.8 (Critical)
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
CWE-400
- Uncontrolled Resource Consumption
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
CWE-401
- Missing Release of Memory after Effective Lifetime
Affected products
Known affected
8 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINAMICS GH150
Siemens / SINAMICS GH150
|
vers:all/* |
Mitigation
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GL150 (with option X30)
Siemens / SINAMICS GL150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS GM150 (with option X30)
Siemens / SINAMICS GM150 (with option X30)
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SH150
Siemens / SINAMICS SH150
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SL150
Siemens / SINAMICS SL150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM120
Siemens / SINAMICS SM120
|
vers:all/* |
Mitigation
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150
Siemens / SINAMICS SM150
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
|
|
SINAMICS SM150i
Siemens / SINAMICS SM150i
|
vers:all/* |
None Available
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
|
References
17 references
{
"document": {
"category": "Siemens Security Advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "SINAMICS medium voltage products, with Sm@rtServer enabled on SIMATIC comfort HMI Panels, are affected by multiple vulnerabilities that could allow an attacker, under certain conditions, to gain full remote access to the HMI. Note that by default Sm@rtServer is disabled, but it can be enabled by the system integrator on request.\n\nSiemens has released updates for the affected products, and recommends to update them to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-286838: Multiple Vulnerabilities in SINAMICS Medium Voltage Products - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"category": "self",
"summary": "SSA-286838: Multiple Vulnerabilities in SINAMICS Medium Voltage Products - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-286838.txt"
},
{
"category": "self",
"summary": "SSA-286838: Multiple Vulnerabilities in SINAMICS Medium Voltage Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-286838.json"
}
],
"title": "SSA-286838: Multiple Vulnerabilities in SINAMICS Medium Voltage Products",
"tracking": {
"current_release_date": "2021-08-10T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-286838",
"initial_release_date": "2021-05-11T00:00:00Z",
"revision_history": [
{
"date": "2021-05-11T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2021-08-10T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Updated information for SINAMICS SL150, SINAMICS SM150 and SINAMICS SM150i"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS GH150",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SINAMICS GH150"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS GL150 (with option X30)",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SINAMICS GL150 (with option X30)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS GM150 (with option X30)",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "SINAMICS GM150 (with option X30)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS SH150",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "SINAMICS SH150"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS SL150",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "SINAMICS SL150"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS SM120",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "SINAMICS SM120"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS SM150",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "SINAMICS SM150"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS SM150i",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "SINAMICS SM150i"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-8259",
"cwe": {
"id": "CWE-665",
"name": "Improper Initialization"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1198 contains multiple memory leaks in VNC client code, which could allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1199.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2019-8259 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8259.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"1",
"2",
"3",
"4",
"6"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"5",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"7"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2019-8259"
},
{
"cve": "CVE-2019-8260",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC client RRE decoder code, caused by multiplication overflow. This vulnerability appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2019-8260 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8260.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"1",
"2",
"3",
"4",
"6"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"5",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"7"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2019-8260"
},
{
"cve": "CVE-2019-8261",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC code inside client CoRRE decoder, caused by multiplication overflow. This vulnerability appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2019-8261 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8261.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"1",
"2",
"3",
"4",
"6"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"5",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"7"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2019-8261"
},
{
"cve": "CVE-2019-8262",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which could result in code execution. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2019-8262 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8262.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"1",
"2",
"3",
"4",
"6"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"5",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"7"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2019-8262"
},
{
"cve": "CVE-2019-8263",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1205 has a stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which could lead to a denial of service (DoS) condition. This vulnerability appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2019-8263 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8263.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"1",
"2",
"3",
"4",
"6"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"5",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"7"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2019-8263"
},
{
"cve": "CVE-2019-8264",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has a out-of-bounds access vulnerability in VNC client inside Ultra2 decoder, which can potentially result in code execution. This vulnerability appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2019-8264 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8264.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"1",
"2",
"3",
"4",
"6"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"5",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"7"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2019-8264"
},
{
"cve": "CVE-2019-8265",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of SETPIXELS macro in VNC client code, which can potentially result in code execution. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1208.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2019-8265 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8265.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"1",
"2",
"3",
"4",
"6"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"5",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"7"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2019-8265"
},
{
"cve": "CVE-2019-8275",
"cwe": {
"id": "CWE-170",
"name": "Improper Null Termination"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which could result in out-of-bound data being accessed by remote users. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2019-8275 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8275.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"1",
"2",
"3",
"4",
"6"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"5",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"7"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2019-8275"
},
{
"cve": "CVE-2019-8277",
"cwe": {
"id": "CWE-665",
"name": "Improper Initialization"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 contains multiple memory leaks in VNC server code, which could allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2019-8277 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8277.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"1",
"2",
"3",
"4",
"6"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"5",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"7"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2019-8277"
},
{
"cve": "CVE-2019-8280",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside RAW decoder, which can potentially result in code execution. This vulnerability appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2019-8280 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8280.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"1",
"2",
"3",
"4",
"6"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"5",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"7"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2019-8280"
},
{
"cve": "CVE-2021-27383",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2021-27383 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27383.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"1",
"2",
"3",
"4",
"6"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"5",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"7"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2021-27383"
},
{
"cve": "CVE-2021-27384",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2021-27384 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27384.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"1",
"2",
"3",
"4",
"6"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"5",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"7"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2021-27384"
},
{
"cve": "CVE-2021-27385",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2021-27385 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27385.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"1",
"2",
"3",
"4",
"6"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"5",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"7"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2021-27385"
},
{
"cve": "CVE-2021-27386",
"cwe": {
"id": "CWE-401",
"name": "Missing Release of Memory after Effective Lifetime"
},
"notes": [
{
"category": "summary",
"text": "SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2021-27386 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27386.json"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109746530/",
"product_ids": [
"1",
"2",
"3",
"4",
"6"
]
},
{
"category": "none_available",
"details": "Currently no remediation is available",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "https://support.industry.siemens.com/cs/ww/en/view/109763890/",
"product_ids": [
"5",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version",
"product_ids": [
"7"
]
},
{
"category": "mitigation",
"details": "As only SIMATIC HMI image versions \u003c V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Disable Sm@rtServer in the SIMATIC HMI Comfort Panels system component of SINAMICS. If this is not possible, Defense-in-Depth should be used. Note: By default Sm@rtServer is disabled, but it can be enabled on request by the system integrator",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "Follow SINAMICS MV Industrial Security guidelines",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
{
"category": "mitigation",
"details": "For any questions regarding update, please contact Siemens customer service or your system integrator.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2021-27386"
}
]
}
SSA-940818
Vulnerability from csaf_siemens - Published: 2021-05-11 00:00 - Updated: 2021-05-11 00:00Summary
SSA-940818: UltraVNC Vulnerabilities in SIMATIC HMIs/WinCC Products
Notes
Summary: UltraVNC vulnerabilities in the affected products listed below could allow remote code execution, information disclosure and Denial-of-Service attacks under certain conditions.
Siemens has released updates for the affected products and recommends to update to the latest versions.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
CWE-665
- Improper Initialization
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
CWE-121
- Stack-based Buffer Overflow
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
CWE-665
- Improper Initialization
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
Siemens / SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
Siemens / SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
< V16 Update 4 |
Vendor Fix
fix
Mitigation
|
References
53 references
{
"document": {
"category": "Siemens Security Advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "UltraVNC vulnerabilities in the affected products listed below could allow remote code execution, information disclosure and Denial-of-Service attacks under certain conditions.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-940818: UltraVNC Vulnerabilities in SIMATIC HMIs/WinCC Products - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"category": "self",
"summary": "SSA-940818: UltraVNC Vulnerabilities in SIMATIC HMIs/WinCC Products - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-940818.txt"
},
{
"category": "self",
"summary": "SSA-940818: UltraVNC Vulnerabilities in SIMATIC HMIs/WinCC Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-940818.json"
}
],
"title": "SSA-940818: UltraVNC Vulnerabilities in SIMATIC HMIs/WinCC Products",
"tracking": {
"current_release_date": "2021-05-11T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-940818",
"initial_release_date": "2021-05-11T00:00:00Z",
"revision_history": [
{
"date": "2021-05-11T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V16 Update 4",
"product": {
"name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V16 Update 4",
"product": {
"name": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V16 Update 4",
"product": {
"name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V16 Update 4",
"product": {
"name": "SIMATIC WinCC Runtime Advanced",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Advanced"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-8259",
"cwe": {
"id": "CWE-665",
"name": "Improper Initialization"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1198 contains multiple memory leaks in VNC client code, which could allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1199.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4"
]
},
"references": [
{
"summary": "CVE-2019-8259 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8259 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8259 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8259 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8259 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8259.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"4"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4"
]
}
],
"title": "CVE-2019-8259"
},
{
"cve": "CVE-2019-8260",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC client RRE decoder code, caused by multiplication overflow. This vulnerability appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4"
]
},
"references": [
{
"summary": "CVE-2019-8260 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8260 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8260 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8260 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8260 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8260.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"4"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4"
]
}
],
"title": "CVE-2019-8260"
},
{
"cve": "CVE-2019-8261",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC code inside client CoRRE decoder, caused by multiplication overflow. This vulnerability appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4"
]
},
"references": [
{
"summary": "CVE-2019-8261 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8261 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8261 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8261 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8261 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8261.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"4"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4"
]
}
],
"title": "CVE-2019-8261"
},
{
"cve": "CVE-2019-8262",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which could result in code execution. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4"
]
},
"references": [
{
"summary": "CVE-2019-8262 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8262 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8262 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8262 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8262 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8262.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"4"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4"
]
}
],
"title": "CVE-2019-8262"
},
{
"cve": "CVE-2019-8263",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1205 has a stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which could lead to a denial of service (DoS) condition. This vulnerability appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4"
]
},
"references": [
{
"summary": "CVE-2019-8263 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8263 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8263 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8263 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8263 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8263.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"4"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4"
]
}
],
"title": "CVE-2019-8263"
},
{
"cve": "CVE-2019-8264",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has a out-of-bounds access vulnerability in VNC client inside Ultra2 decoder, which can potentially result in code execution. This vulnerability appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4"
]
},
"references": [
{
"summary": "CVE-2019-8264 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8264 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8264 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8264 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8264 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8264.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"4"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4"
]
}
],
"title": "CVE-2019-8264"
},
{
"cve": "CVE-2019-8265",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of SETPIXELS macro in VNC client code, which can potentially result in code execution. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1208.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4"
]
},
"references": [
{
"summary": "CVE-2019-8265 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8265 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8265 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8265 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8265 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8265.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"4"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4"
]
}
],
"title": "CVE-2019-8265"
},
{
"cve": "CVE-2019-8275",
"cwe": {
"id": "CWE-170",
"name": "Improper Null Termination"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which could result in out-of-bound data being accessed by remote users. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4"
]
},
"references": [
{
"summary": "CVE-2019-8275 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8275 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8275 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8275 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8275 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8275.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"4"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4"
]
}
],
"title": "CVE-2019-8275"
},
{
"cve": "CVE-2019-8277",
"cwe": {
"id": "CWE-665",
"name": "Improper Initialization"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 contains multiple memory leaks in VNC server code, which could allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This vulnerability appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4"
]
},
"references": [
{
"summary": "CVE-2019-8277 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8277 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8277 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8277 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8277 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8277.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"4"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4"
]
}
],
"title": "CVE-2019-8277"
},
{
"cve": "CVE-2019-8280",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside RAW decoder, which can potentially result in code execution. This vulnerability appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4"
]
},
"references": [
{
"summary": "CVE-2019-8280 - SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8280 - SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8280 - SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-8280 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"summary": "CVE-2019-8280 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8280.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"4"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109776018/"
},
{
"category": "mitigation",
"details": "Restrict access to port 5900/tcp to trusted IP addresses only",
"product_ids": [
"1",
"2",
"3",
"4"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4"
]
}
],
"title": "CVE-2019-8280"
}
]
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…