CVE-2020-28895 (GCVE-0-2020-28895)
Vulnerability from cvelistv5 – Published: 2021-02-03 15:16 – Updated: 2024-08-04 16:41- n/a
| URL | Tags |
|---|---|
| https://support2.windriver.com/index.php?page=def… | x_refsource_MISC |
| https://support2.windriver.com/index.php?page=cve… | x_refsource_MISC |
| https://www.oracle.com/security-alerts/cpuapr2022.html | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:41:00.095Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Reported by Omri Ben Bassat \u003cv-obenbassat@microsoft.com\u003e"
}
],
"datePublic": "2020-12-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-19T23:22:39.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "integer overflow in calloc",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-28895",
"STATE": "PUBLIC",
"TITLE": "integer overflow in calloc"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Reported by Omri Ben Bassat \u003cv-obenbassat@microsoft.com\u003e"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327",
"refsource": "MISC",
"url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327"
},
{
"name": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895",
"refsource": "MISC",
"url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895"
},
{
"name": "https://www.oracle.com/security-alerts/cpuapr2022.html",
"refsource": "MISC",
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
}
]
},
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-28895",
"datePublished": "2021-02-03T15:16:34.000Z",
"dateReserved": "2020-11-17T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:41:00.095Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-28895",
"date": "2026-06-02",
"epss": "0.00333",
"percentile": "0.56364"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"6.9\", \"versionEndExcluding\": \"6.9.4.12\", \"matchCriteriaId\": \"2E27E761-92D8-4A67-8D23-213E0C7BFFC6\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:windriver:vxworks:6.9.4.12:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"69674D4D-2848-46BA-9367-7AA85EE2CD99\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:windriver:vxworks:6.9.4.12:rolling_cumulative_patch_layer1:*:*:*:*:*:*\", \"matchCriteriaId\": \"1052B8F5-1BC4-46B6-A8F1-F1BF9A40DDAF\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:oracle:communications_eagle:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"46.8.0\", \"versionEndIncluding\": \"48.6.2\", \"matchCriteriaId\": \"1507EFE2-DA83-42D7-B075-91EE060B6B35\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:oracle:communications_eagle:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"46.9.1\", \"versionEndIncluding\": \"46.9.3\", \"matchCriteriaId\": \"4143A5F6-CD91-4209-A52B-98854CCAC987\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:oracle:communications_eagle:46.7.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9FED9166-7A2A-453D-9792-7A6361CEF594\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.\"}, {\"lang\": \"es\", \"value\": \"En Wind River VxWorks, el asignador de memoria presenta un posible desbordamiento en el calculo del tama\\u00f1o del bloque de memoria que se asignar\\u00e1 por medio de la funci\\u00f3n calloc().\u0026#xa0;Como resultado, la memoria real asignada es menor que el tama\\u00f1o del b\\u00fafer especificado por los argumentos, conllevando a una corrupci\\u00f3n en la memoria\"}]",
"id": "CVE-2020-28895",
"lastModified": "2024-11-21T05:23:14.430",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cve@mitre.org\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.4}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 7.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2021-02-03T16:15:13.633",
"references": "[{\"url\": \"https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327\", \"source\": \"cve@mitre.org\", \"tags\": [\"Permissions Required\"]}, {\"url\": \"https://www.oracle.com/security-alerts/cpuapr2022.html\", \"source\": \"cve@mitre.org\", \"tags\": [\"Patch\", \"Third Party Advisory\"]}, {\"url\": \"https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Permissions Required\"]}, {\"url\": \"https://www.oracle.com/security-alerts/cpuapr2022.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Third Party Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-190\"}, {\"lang\": \"en\", \"value\": \"CWE-787\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-28895\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-02-03T16:15:13.633\",\"lastModified\":\"2024-11-21T05:23:14.430\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.\"},{\"lang\":\"es\",\"value\":\"En Wind River VxWorks, el asignador de memoria presenta un posible desbordamiento en el calculo del tama\u00f1o del bloque de memoria que se asignar\u00e1 por medio de la funci\u00f3n calloc().\u0026#xa0;Como resultado, la memoria real asignada es menor que el tama\u00f1o del b\u00fafer especificado por los argumentos, conllevando a una corrupci\u00f3n en la memoria\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":3.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-190\"},{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.9\",\"versionEndExcluding\":\"6.9.4.12\",\"matchCriteriaId\":\"2E27E761-92D8-4A67-8D23-213E0C7BFFC6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:windriver:vxworks:6.9.4.12:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"69674D4D-2848-46BA-9367-7AA85EE2CD99\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:windriver:vxworks:6.9.4.12:rolling_cumulative_patch_layer1:*:*:*:*:*:*\",\"matchCriteriaId\":\"1052B8F5-1BC4-46B6-A8F1-F1BF9A40DDAF\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:communications_eagle:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"46.8.0\",\"versionEndIncluding\":\"48.6.2\",\"matchCriteriaId\":\"1507EFE2-DA83-42D7-B075-91EE060B6B35\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:communications_eagle:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"46.9.1\",\"versionEndIncluding\":\"46.9.3\",\"matchCriteriaId\":\"4143A5F6-CD91-4209-A52B-98854CCAC987\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:communications_eagle:46.7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9FED9166-7A2A-453D-9792-7A6361CEF594\"}]}]}],\"references\":[{\"url\":\"https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327\",\"source\":\"cve@mitre.org\",\"tags\":[\"Permissions Required\"]},{\"url\":\"https://www.oracle.com/security-alerts/cpuapr2022.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Permissions Required\"]},{\"url\":\"https://www.oracle.com/security-alerts/cpuapr2022.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\"]}]}}"
}
}
ICSA-23-103-13
Vulnerability from csaf_cisa - Published: 2023-04-11 00:00 - Updated: 2024-08-13 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)
Siemens / SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)
|
6GK5200-4AH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)
Siemens / SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)
|
6GK5201-3BH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)
Siemens / SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)
|
6GK5201-3JR00-2BA6
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)
Siemens / SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)
|
6GK5202-2BB00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)
Siemens / SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)
|
6GK5202-2BB10-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)
Siemens / SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)
|
6GK5202-2BH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)
Siemens / SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)
|
6GK5202-2JR00-2BA6
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X204-2 (6GK5204-2BB10-2AA3)
Siemens / SCALANCE X204-2 (6GK5204-2BB10-2AA3)
|
6GK5204-2BB10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2FM (6GK5204-2BB11-2AA3)
Siemens / SCALANCE X204-2FM (6GK5204-2BB11-2AA3)
|
6GK5204-2BB11-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2LD (6GK5204-2BC10-2AA3)
Siemens / SCALANCE X204-2LD (6GK5204-2BC10-2AA3)
|
6GK5204-2BC10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)
Siemens / SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)
|
6GK5204-2BC10-2CA2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2TS (6GK5204-2BB10-2CA2)
Siemens / SCALANCE X204-2TS (6GK5204-2BB10-2CA2)
|
6GK5204-2BB10-2CA2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204IRT (6GK5204-0BA00-2BA3)
Siemens / SCALANCE X204IRT (6GK5204-0BA00-2BA3)
|
6GK5204-0BA00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X204IRT (6GK5204-0BA10-2BA3)
Siemens / SCALANCE X204IRT (6GK5204-0BA10-2BA3)
|
6GK5204-0BA10-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)
Siemens / SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)
|
6GK5204-0JA00-2BA6
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X206-1 (6GK5206-1BB10-2AA3)
Siemens / SCALANCE X206-1 (6GK5206-1BB10-2AA3)
|
6GK5206-1BB10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X206-1LD (6GK5206-1BC10-2AA3)
Siemens / SCALANCE X206-1LD (6GK5206-1BC10-2AA3)
|
6GK5206-1BC10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X208 (6GK5208-0BA10-2AA3)
Siemens / SCALANCE X208 (6GK5208-0BA10-2AA3)
|
6GK5208-0BA10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X208PRO (6GK5208-0HA10-2AA6)
Siemens / SCALANCE X208PRO (6GK5208-0HA10-2AA6)
|
6GK5208-0HA10-2AA6
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X212-2 (6GK5212-2BB00-2AA3)
Siemens / SCALANCE X212-2 (6GK5212-2BB00-2AA3)
|
6GK5212-2BB00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X212-2LD (6GK5212-2BC00-2AA3)
Siemens / SCALANCE X212-2LD (6GK5212-2BC00-2AA3)
|
6GK5212-2BC00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X216 (6GK5216-0BA00-2AA3)
Siemens / SCALANCE X216 (6GK5216-0BA00-2AA3)
|
6GK5216-0BA00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X224 (6GK5224-0BA00-2AA3)
Siemens / SCALANCE X224 (6GK5224-0BA00-2AA3)
|
6GK5224-0BA00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)
Siemens / SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)
|
6GK5302-7GD00-3GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)
Siemens / SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)
|
6GK5302-7GD00-3EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)
Siemens / SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)
|
6GK5302-7GD00-1GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)
Siemens / SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)
|
6GK5302-7GD00-1EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)
Siemens / SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)
|
6GK5302-7GD00-4GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)
Siemens / SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)
|
6GK5302-7GD00-4EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)
Siemens / SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)
|
6GK5302-7GD00-2GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)
Siemens / SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)
|
6GK5302-7GD00-2EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X304-2FE (6GK5304-2BD00-2AA3)
Siemens / SCALANCE X304-2FE (6GK5304-2BD00-2AA3)
|
6GK5304-2BD00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)
Siemens / SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)
|
6GK5306-1BF00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)
Siemens / SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)
|
6GK5307-2FD00-3GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)
Siemens / SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)
|
6GK5307-2FD00-3EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)
Siemens / SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)
|
6GK5307-2FD00-1GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)
Siemens / SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)
|
6GK5307-2FD00-1EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)
Siemens / SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)
|
6GK5307-2FD00-4GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)
Siemens / SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)
|
6GK5307-2FD00-4EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)
Siemens / SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)
|
6GK5307-2FD00-2GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)
Siemens / SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)
|
6GK5307-2FD00-2EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3 (6GK5307-3BL00-2AA3)
Siemens / SCALANCE X307-3 (6GK5307-3BL00-2AA3)
|
6GK5307-3BL00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3 (6GK5307-3BL10-2AA3)
Siemens / SCALANCE X307-3 (6GK5307-3BL10-2AA3)
|
6GK5307-3BL10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3LD (6GK5307-3BM00-2AA3)
Siemens / SCALANCE X307-3LD (6GK5307-3BM00-2AA3)
|
6GK5307-3BM00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3LD (6GK5307-3BM10-2AA3)
Siemens / SCALANCE X307-3LD (6GK5307-3BM10-2AA3)
|
6GK5307-3BM10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2 (6GK5308-2FL00-2AA3)
Siemens / SCALANCE X308-2 (6GK5308-2FL00-2AA3)
|
6GK5308-2FL00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2 (6GK5308-2FL10-2AA3)
Siemens / SCALANCE X308-2 (6GK5308-2FL10-2AA3)
|
6GK5308-2FL10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LD (6GK5308-2FM00-2AA3)
Siemens / SCALANCE X308-2LD (6GK5308-2FM00-2AA3)
|
6GK5308-2FM00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LD (6GK5308-2FM10-2AA3)
Siemens / SCALANCE X308-2LD (6GK5308-2FM10-2AA3)
|
6GK5308-2FM10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH (6GK5308-2FN00-2AA3)
Siemens / SCALANCE X308-2LH (6GK5308-2FN00-2AA3)
|
6GK5308-2FN00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH (6GK5308-2FN10-2AA3)
Siemens / SCALANCE X308-2LH (6GK5308-2FN10-2AA3)
|
6GK5308-2FN10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)
Siemens / SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)
|
6GK5308-2FP00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)
Siemens / SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)
|
6GK5308-2FP10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M (6GK5308-2GG00-2AA2)
Siemens / SCALANCE X308-2M (6GK5308-2GG00-2AA2)
|
6GK5308-2GG00-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M (6GK5308-2GG10-2AA2)
Siemens / SCALANCE X308-2M (6GK5308-2GG10-2AA2)
|
6GK5308-2GG10-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)
Siemens / SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)
|
6GK5308-2QG00-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)
Siemens / SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)
|
6GK5308-2QG10-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)
Siemens / SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)
|
6GK5308-2GG00-2CA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)
Siemens / SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)
|
6GK5308-2GG10-2CA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310 (6GK5310-0FA00-2AA3)
Siemens / SCALANCE X310 (6GK5310-0FA00-2AA3)
|
6GK5310-0FA00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310 (6GK5310-0FA10-2AA3)
Siemens / SCALANCE X310 (6GK5310-0FA10-2AA3)
|
6GK5310-0FA10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310FE (6GK5310-0BA00-2AA3)
Siemens / SCALANCE X310FE (6GK5310-0BA00-2AA3)
|
6GK5310-0BA00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310FE (6GK5310-0BA10-2AA3)
Siemens / SCALANCE X310FE (6GK5310-0BA10-2AA3)
|
6GK5310-0BA10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)
Siemens / SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)
|
6GK5320-1BD00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)
Siemens / SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)
|
6GK5320-3BF00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X408-2 (6GK5408-2FD00-2AA2)
Siemens / SCALANCE X408-2 (6GK5408-2FD00-2AA2)
|
6GK5408-2FD00-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)
Siemens / SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)
|
6GK5201-3BH00-2BD2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)
Siemens / SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)
|
6GK5202-2BH00-2BD2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF204 (6GK5204-0BA00-2AF2)
Siemens / SCALANCE XF204 (6GK5204-0BA00-2AF2)
|
6GK5204-0BA00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XF204-2 (6GK5204-2BC00-2AF2)
Siemens / SCALANCE XF204-2 (6GK5204-2BC00-2AF2)
|
6GK5204-2BC00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)
Siemens / SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)
|
6GK5204-2AA00-2BD2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF204IRT (6GK5204-0BA00-2BF2)
Siemens / SCALANCE XF204IRT (6GK5204-0BA00-2BF2)
|
6GK5204-0BA00-2BF2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF206-1 (6GK5206-1BC00-2AF2)
Siemens / SCALANCE XF206-1 (6GK5206-1BC00-2AF2)
|
6GK5206-1BC00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XF208 (6GK5208-0BA00-2AF2)
Siemens / SCALANCE XF208 (6GK5208-0BA00-2AF2)
|
6GK5208-0BA00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)
Siemens / SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)
|
6GK5324-0GG00-3AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)
Siemens / SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)
|
6GK5324-0GG10-3AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)
Siemens / SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)
|
6GK5324-0GG00-3HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)
Siemens / SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)
|
6GK5324-0GG10-3HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)
Siemens / SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)
|
6GK5324-0GG00-1AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)
Siemens / SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)
|
6GK5324-0GG10-1AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)
Siemens / SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)
|
6GK5324-0GG00-1HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)
Siemens / SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)
|
6GK5324-0GG10-1HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)
Siemens / SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)
|
6GK5324-0GG00-1CR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)
Siemens / SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)
|
6GK5324-0GG10-1CR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)
|
6GK5324-4GG00-3ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)
|
6GK5324-4GG10-3ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)
|
6GK5324-4GG00-3JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)
|
6GK5324-4GG10-3JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)
|
6GK5324-4GG00-1ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)
|
6GK5324-4GG10-1ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)
|
6GK5324-4GG00-1JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)
|
6GK5324-4GG10-1JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)
|
6GK5324-4GG00-4ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)
|
6GK5324-4GG10-4ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)
|
6GK5324-4GG00-4JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)
|
6GK5324-4GG10-4JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)
|
6GK5324-4GG00-2ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)
|
6GK5324-4GG10-2ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)
|
6GK5324-4GG00-2JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)
|
6GK5324-4GG10-2JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)
Siemens / SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)
|
6GK5324-4QG00-3AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)
Siemens / SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)
|
6GK5324-4QG00-3HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)
Siemens / SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)
|
6GK5324-4QG00-1AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)
Siemens / SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)
|
6GK5324-4QG00-1HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)
Siemens / SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)
|
6GK5324-4QG00-1CR2
|
vers:all/* |
No Fix Planned
|
|
SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)
Siemens / SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)
|
6AG1202-2BH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)
Siemens / SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)
|
6AG1308-2FL10-4AA3
|
vers:all/* |
No Fix Planned
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)
Siemens / SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)
|
6GK5200-4AH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)
Siemens / SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)
|
6GK5201-3BH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)
Siemens / SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)
|
6GK5201-3JR00-2BA6
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)
Siemens / SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)
|
6GK5202-2BB00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)
Siemens / SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)
|
6GK5202-2BB10-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)
Siemens / SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)
|
6GK5202-2BH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)
Siemens / SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)
|
6GK5202-2JR00-2BA6
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X204-2 (6GK5204-2BB10-2AA3)
Siemens / SCALANCE X204-2 (6GK5204-2BB10-2AA3)
|
6GK5204-2BB10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2FM (6GK5204-2BB11-2AA3)
Siemens / SCALANCE X204-2FM (6GK5204-2BB11-2AA3)
|
6GK5204-2BB11-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2LD (6GK5204-2BC10-2AA3)
Siemens / SCALANCE X204-2LD (6GK5204-2BC10-2AA3)
|
6GK5204-2BC10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)
Siemens / SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)
|
6GK5204-2BC10-2CA2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2TS (6GK5204-2BB10-2CA2)
Siemens / SCALANCE X204-2TS (6GK5204-2BB10-2CA2)
|
6GK5204-2BB10-2CA2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204IRT (6GK5204-0BA00-2BA3)
Siemens / SCALANCE X204IRT (6GK5204-0BA00-2BA3)
|
6GK5204-0BA00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X204IRT (6GK5204-0BA10-2BA3)
Siemens / SCALANCE X204IRT (6GK5204-0BA10-2BA3)
|
6GK5204-0BA10-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)
Siemens / SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)
|
6GK5204-0JA00-2BA6
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X206-1 (6GK5206-1BB10-2AA3)
Siemens / SCALANCE X206-1 (6GK5206-1BB10-2AA3)
|
6GK5206-1BB10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X206-1LD (6GK5206-1BC10-2AA3)
Siemens / SCALANCE X206-1LD (6GK5206-1BC10-2AA3)
|
6GK5206-1BC10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X208 (6GK5208-0BA10-2AA3)
Siemens / SCALANCE X208 (6GK5208-0BA10-2AA3)
|
6GK5208-0BA10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X208PRO (6GK5208-0HA10-2AA6)
Siemens / SCALANCE X208PRO (6GK5208-0HA10-2AA6)
|
6GK5208-0HA10-2AA6
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X212-2 (6GK5212-2BB00-2AA3)
Siemens / SCALANCE X212-2 (6GK5212-2BB00-2AA3)
|
6GK5212-2BB00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X212-2LD (6GK5212-2BC00-2AA3)
Siemens / SCALANCE X212-2LD (6GK5212-2BC00-2AA3)
|
6GK5212-2BC00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X216 (6GK5216-0BA00-2AA3)
Siemens / SCALANCE X216 (6GK5216-0BA00-2AA3)
|
6GK5216-0BA00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X224 (6GK5224-0BA00-2AA3)
Siemens / SCALANCE X224 (6GK5224-0BA00-2AA3)
|
6GK5224-0BA00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)
Siemens / SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)
|
6GK5302-7GD00-3GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)
Siemens / SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)
|
6GK5302-7GD00-3EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)
Siemens / SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)
|
6GK5302-7GD00-1GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)
Siemens / SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)
|
6GK5302-7GD00-1EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)
Siemens / SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)
|
6GK5302-7GD00-4GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)
Siemens / SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)
|
6GK5302-7GD00-4EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)
Siemens / SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)
|
6GK5302-7GD00-2GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)
Siemens / SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)
|
6GK5302-7GD00-2EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X304-2FE (6GK5304-2BD00-2AA3)
Siemens / SCALANCE X304-2FE (6GK5304-2BD00-2AA3)
|
6GK5304-2BD00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)
Siemens / SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)
|
6GK5306-1BF00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)
Siemens / SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)
|
6GK5307-2FD00-3GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)
Siemens / SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)
|
6GK5307-2FD00-3EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)
Siemens / SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)
|
6GK5307-2FD00-1GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)
Siemens / SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)
|
6GK5307-2FD00-1EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)
Siemens / SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)
|
6GK5307-2FD00-4GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)
Siemens / SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)
|
6GK5307-2FD00-4EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)
Siemens / SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)
|
6GK5307-2FD00-2GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)
Siemens / SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)
|
6GK5307-2FD00-2EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3 (6GK5307-3BL00-2AA3)
Siemens / SCALANCE X307-3 (6GK5307-3BL00-2AA3)
|
6GK5307-3BL00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3 (6GK5307-3BL10-2AA3)
Siemens / SCALANCE X307-3 (6GK5307-3BL10-2AA3)
|
6GK5307-3BL10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3LD (6GK5307-3BM00-2AA3)
Siemens / SCALANCE X307-3LD (6GK5307-3BM00-2AA3)
|
6GK5307-3BM00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3LD (6GK5307-3BM10-2AA3)
Siemens / SCALANCE X307-3LD (6GK5307-3BM10-2AA3)
|
6GK5307-3BM10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2 (6GK5308-2FL00-2AA3)
Siemens / SCALANCE X308-2 (6GK5308-2FL00-2AA3)
|
6GK5308-2FL00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2 (6GK5308-2FL10-2AA3)
Siemens / SCALANCE X308-2 (6GK5308-2FL10-2AA3)
|
6GK5308-2FL10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LD (6GK5308-2FM00-2AA3)
Siemens / SCALANCE X308-2LD (6GK5308-2FM00-2AA3)
|
6GK5308-2FM00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LD (6GK5308-2FM10-2AA3)
Siemens / SCALANCE X308-2LD (6GK5308-2FM10-2AA3)
|
6GK5308-2FM10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH (6GK5308-2FN00-2AA3)
Siemens / SCALANCE X308-2LH (6GK5308-2FN00-2AA3)
|
6GK5308-2FN00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH (6GK5308-2FN10-2AA3)
Siemens / SCALANCE X308-2LH (6GK5308-2FN10-2AA3)
|
6GK5308-2FN10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)
Siemens / SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)
|
6GK5308-2FP00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)
Siemens / SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)
|
6GK5308-2FP10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M (6GK5308-2GG00-2AA2)
Siemens / SCALANCE X308-2M (6GK5308-2GG00-2AA2)
|
6GK5308-2GG00-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M (6GK5308-2GG10-2AA2)
Siemens / SCALANCE X308-2M (6GK5308-2GG10-2AA2)
|
6GK5308-2GG10-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)
Siemens / SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)
|
6GK5308-2QG00-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)
Siemens / SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)
|
6GK5308-2QG10-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)
Siemens / SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)
|
6GK5308-2GG00-2CA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)
Siemens / SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)
|
6GK5308-2GG10-2CA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310 (6GK5310-0FA00-2AA3)
Siemens / SCALANCE X310 (6GK5310-0FA00-2AA3)
|
6GK5310-0FA00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310 (6GK5310-0FA10-2AA3)
Siemens / SCALANCE X310 (6GK5310-0FA10-2AA3)
|
6GK5310-0FA10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310FE (6GK5310-0BA00-2AA3)
Siemens / SCALANCE X310FE (6GK5310-0BA00-2AA3)
|
6GK5310-0BA00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310FE (6GK5310-0BA10-2AA3)
Siemens / SCALANCE X310FE (6GK5310-0BA10-2AA3)
|
6GK5310-0BA10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)
Siemens / SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)
|
6GK5320-1BD00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)
Siemens / SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)
|
6GK5320-3BF00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X408-2 (6GK5408-2FD00-2AA2)
Siemens / SCALANCE X408-2 (6GK5408-2FD00-2AA2)
|
6GK5408-2FD00-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)
Siemens / SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)
|
6GK5201-3BH00-2BD2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)
Siemens / SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)
|
6GK5202-2BH00-2BD2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF204 (6GK5204-0BA00-2AF2)
Siemens / SCALANCE XF204 (6GK5204-0BA00-2AF2)
|
6GK5204-0BA00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XF204-2 (6GK5204-2BC00-2AF2)
Siemens / SCALANCE XF204-2 (6GK5204-2BC00-2AF2)
|
6GK5204-2BC00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)
Siemens / SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)
|
6GK5204-2AA00-2BD2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF204IRT (6GK5204-0BA00-2BF2)
Siemens / SCALANCE XF204IRT (6GK5204-0BA00-2BF2)
|
6GK5204-0BA00-2BF2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF206-1 (6GK5206-1BC00-2AF2)
Siemens / SCALANCE XF206-1 (6GK5206-1BC00-2AF2)
|
6GK5206-1BC00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XF208 (6GK5208-0BA00-2AF2)
Siemens / SCALANCE XF208 (6GK5208-0BA00-2AF2)
|
6GK5208-0BA00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)
Siemens / SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)
|
6GK5324-0GG00-3AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)
Siemens / SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)
|
6GK5324-0GG10-3AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)
Siemens / SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)
|
6GK5324-0GG00-3HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)
Siemens / SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)
|
6GK5324-0GG10-3HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)
Siemens / SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)
|
6GK5324-0GG00-1AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)
Siemens / SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)
|
6GK5324-0GG10-1AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)
Siemens / SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)
|
6GK5324-0GG00-1HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)
Siemens / SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)
|
6GK5324-0GG10-1HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)
Siemens / SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)
|
6GK5324-0GG00-1CR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)
Siemens / SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)
|
6GK5324-0GG10-1CR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)
|
6GK5324-4GG00-3ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)
|
6GK5324-4GG10-3ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)
|
6GK5324-4GG00-3JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)
|
6GK5324-4GG10-3JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)
|
6GK5324-4GG00-1ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)
|
6GK5324-4GG10-1ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)
|
6GK5324-4GG00-1JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)
|
6GK5324-4GG10-1JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)
|
6GK5324-4GG00-4ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)
|
6GK5324-4GG10-4ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)
|
6GK5324-4GG00-4JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)
|
6GK5324-4GG10-4JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)
|
6GK5324-4GG00-2ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)
|
6GK5324-4GG10-2ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)
|
6GK5324-4GG00-2JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)
|
6GK5324-4GG10-2JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)
Siemens / SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)
|
6GK5324-4QG00-3AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)
Siemens / SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)
|
6GK5324-4QG00-3HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)
Siemens / SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)
|
6GK5324-4QG00-1AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)
Siemens / SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)
|
6GK5324-4QG00-1HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)
Siemens / SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)
|
6GK5324-4QG00-1CR2
|
vers:all/* |
No Fix Planned
|
|
SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)
Siemens / SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)
|
6AG1202-2BH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)
Siemens / SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)
|
6AG1308-2FL10-4AA3
|
vers:all/* |
No Fix Planned
|
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Siemens has released a new firmware version for SCALANCE X-200 and X-200 IRT switches that address Bad Alloc vulnerabilities in the underlying operating system and recommends to update to the latest versions. Siemens recommends countermeasures for products where updates are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-813746: BadAlloc Vulnerabilities in SCALANCE X-200, X-200IRT, and X-300 Switch Families - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-813746.json"
},
{
"category": "self",
"summary": "SSA-813746: BadAlloc Vulnerabilities in SCALANCE X-200, X-200IRT, and X-300 Switch Families - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-813746.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-103-13 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-103-13.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-103-13 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-13"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SCALANCE Switch Families",
"tracking": {
"current_release_date": "2024-08-13T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-103-13",
"initial_release_date": "2023-04-11T00:00:00.000000Z",
"revision_history": [
{
"date": "2023-04-11T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2024-08-13T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Updated description and CVSS for CVE-2020-35198"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)",
"product_id": "CSAFPID-0001",
"product_identification_helper": {
"model_numbers": [
"6GK5200-4AH00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)",
"product_id": "CSAFPID-0002",
"product_identification_helper": {
"model_numbers": [
"6GK5201-3BH00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)",
"product_id": "CSAFPID-0003",
"product_identification_helper": {
"model_numbers": [
"6GK5201-3JR00-2BA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)",
"product_id": "CSAFPID-0004",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2BB00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)",
"product_id": "CSAFPID-0005",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2BB10-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)",
"product_id": "CSAFPID-0006",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2BH00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)",
"product_id": "CSAFPID-0007",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2JR00-2BA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X204-2 (6GK5204-2BB10-2AA3)",
"product_id": "CSAFPID-0008",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2BB10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204-2 (6GK5204-2BB10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X204-2FM (6GK5204-2BB11-2AA3)",
"product_id": "CSAFPID-0009",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2BB11-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204-2FM (6GK5204-2BB11-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X204-2LD (6GK5204-2BC10-2AA3)",
"product_id": "CSAFPID-0010",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2BC10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204-2LD (6GK5204-2BC10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)",
"product_id": "CSAFPID-0011",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2BC10-2CA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X204-2TS (6GK5204-2BB10-2CA2)",
"product_id": "CSAFPID-0012",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2BB10-2CA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204-2TS (6GK5204-2BB10-2CA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X204IRT (6GK5204-0BA00-2BA3)",
"product_id": "CSAFPID-0013",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204IRT (6GK5204-0BA00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X204IRT (6GK5204-0BA10-2BA3)",
"product_id": "CSAFPID-0014",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA10-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204IRT (6GK5204-0BA10-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)",
"product_id": "CSAFPID-0015",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0JA00-2BA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X206-1 (6GK5206-1BB10-2AA3)",
"product_id": "CSAFPID-0016",
"product_identification_helper": {
"model_numbers": [
"6GK5206-1BB10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X206-1 (6GK5206-1BB10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X206-1LD (6GK5206-1BC10-2AA3)",
"product_id": "CSAFPID-0017",
"product_identification_helper": {
"model_numbers": [
"6GK5206-1BC10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X206-1LD (6GK5206-1BC10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X208 (6GK5208-0BA10-2AA3)",
"product_id": "CSAFPID-0018",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X208 (6GK5208-0BA10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X208PRO (6GK5208-0HA10-2AA6)",
"product_id": "CSAFPID-0019",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0HA10-2AA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X208PRO (6GK5208-0HA10-2AA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X212-2 (6GK5212-2BB00-2AA3)",
"product_id": "CSAFPID-0020",
"product_identification_helper": {
"model_numbers": [
"6GK5212-2BB00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X212-2 (6GK5212-2BB00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X212-2LD (6GK5212-2BC00-2AA3)",
"product_id": "CSAFPID-0021",
"product_identification_helper": {
"model_numbers": [
"6GK5212-2BC00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X212-2LD (6GK5212-2BC00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X216 (6GK5216-0BA00-2AA3)",
"product_id": "CSAFPID-0022",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0BA00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X216 (6GK5216-0BA00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X224 (6GK5224-0BA00-2AA3)",
"product_id": "CSAFPID-0023",
"product_identification_helper": {
"model_numbers": [
"6GK5224-0BA00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X224 (6GK5224-0BA00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)",
"product_id": "CSAFPID-0024",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-2EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)",
"product_id": "CSAFPID-0025",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-2GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)",
"product_id": "CSAFPID-0026",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-4EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)",
"product_id": "CSAFPID-0027",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-4GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)",
"product_id": "CSAFPID-0028",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-1EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)",
"product_id": "CSAFPID-0029",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-1GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)",
"product_id": "CSAFPID-0030",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-3EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)",
"product_id": "CSAFPID-0031",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-3GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X304-2FE (6GK5304-2BD00-2AA3)",
"product_id": "CSAFPID-0032",
"product_identification_helper": {
"model_numbers": [
"6GK5304-2BD00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X304-2FE (6GK5304-2BD00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)",
"product_id": "CSAFPID-0033",
"product_identification_helper": {
"model_numbers": [
"6GK5306-1BF00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)",
"product_id": "CSAFPID-0034",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-2EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)",
"product_id": "CSAFPID-0035",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-2GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)",
"product_id": "CSAFPID-0036",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-4EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)",
"product_id": "CSAFPID-0037",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-4GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)",
"product_id": "CSAFPID-0038",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-1EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)",
"product_id": "CSAFPID-0039",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-1GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)",
"product_id": "CSAFPID-0040",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-3EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)",
"product_id": "CSAFPID-0041",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-3GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-3 (6GK5307-3BL00-2AA3)",
"product_id": "CSAFPID-0042",
"product_identification_helper": {
"model_numbers": [
"6GK5307-3BL00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-3 (6GK5307-3BL00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-3 (6GK5307-3BL10-2AA3)",
"product_id": "CSAFPID-0043",
"product_identification_helper": {
"model_numbers": [
"6GK5307-3BL10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-3 (6GK5307-3BL10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-3LD (6GK5307-3BM00-2AA3)",
"product_id": "CSAFPID-0044",
"product_identification_helper": {
"model_numbers": [
"6GK5307-3BM00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-3LD (6GK5307-3BM00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-3LD (6GK5307-3BM10-2AA3)",
"product_id": "CSAFPID-0045",
"product_identification_helper": {
"model_numbers": [
"6GK5307-3BM10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-3LD (6GK5307-3BM10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2 (6GK5308-2FL00-2AA3)",
"product_id": "CSAFPID-0046",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FL00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2 (6GK5308-2FL00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2 (6GK5308-2FL10-2AA3)",
"product_id": "CSAFPID-0047",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FL10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2 (6GK5308-2FL10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2LD (6GK5308-2FM00-2AA3)",
"product_id": "CSAFPID-0048",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FM00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LD (6GK5308-2FM00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2LD (6GK5308-2FM10-2AA3)",
"product_id": "CSAFPID-0049",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FM10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LD (6GK5308-2FM10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2LH (6GK5308-2FN00-2AA3)",
"product_id": "CSAFPID-0050",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FN00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LH (6GK5308-2FN00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2LH (6GK5308-2FN10-2AA3)",
"product_id": "CSAFPID-0051",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FN10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LH (6GK5308-2FN10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)",
"product_id": "CSAFPID-0052",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FP00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)",
"product_id": "CSAFPID-0053",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FP10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2M (6GK5308-2GG00-2AA2)",
"product_id": "CSAFPID-0054",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2GG00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M (6GK5308-2GG00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2M (6GK5308-2GG10-2AA2)",
"product_id": "CSAFPID-0055",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2GG10-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M (6GK5308-2GG10-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)",
"product_id": "CSAFPID-0056",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2QG00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)",
"product_id": "CSAFPID-0057",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2QG10-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)",
"product_id": "CSAFPID-0058",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2GG00-2CA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)",
"product_id": "CSAFPID-0059",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2GG10-2CA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X310 (6GK5310-0FA00-2AA3)",
"product_id": "CSAFPID-0060",
"product_identification_helper": {
"model_numbers": [
"6GK5310-0FA00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X310 (6GK5310-0FA00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X310 (6GK5310-0FA10-2AA3)",
"product_id": "CSAFPID-0061",
"product_identification_helper": {
"model_numbers": [
"6GK5310-0FA10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X310 (6GK5310-0FA10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X310FE (6GK5310-0BA00-2AA3)",
"product_id": "CSAFPID-0062",
"product_identification_helper": {
"model_numbers": [
"6GK5310-0BA00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X310FE (6GK5310-0BA00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X310FE (6GK5310-0BA10-2AA3)",
"product_id": "CSAFPID-0063",
"product_identification_helper": {
"model_numbers": [
"6GK5310-0BA10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X310FE (6GK5310-0BA10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)",
"product_id": "CSAFPID-0064",
"product_identification_helper": {
"model_numbers": [
"6GK5320-1BD00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)",
"product_id": "CSAFPID-0065",
"product_identification_helper": {
"model_numbers": [
"6GK5320-3BF00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X408-2 (6GK5408-2FD00-2AA2)",
"product_id": "CSAFPID-0066",
"product_identification_helper": {
"model_numbers": [
"6GK5408-2FD00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X408-2 (6GK5408-2FD00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)",
"product_id": "CSAFPID-0067",
"product_identification_helper": {
"model_numbers": [
"6GK5201-3BH00-2BD2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)",
"product_id": "CSAFPID-0068",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2BH00-2BD2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE XF204 (6GK5204-0BA00-2AF2)",
"product_id": "CSAFPID-0069",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2AF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204 (6GK5204-0BA00-2AF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE XF204-2 (6GK5204-2BC00-2AF2)",
"product_id": "CSAFPID-0070",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2BC00-2AF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204-2 (6GK5204-2BC00-2AF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)",
"product_id": "CSAFPID-0071",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2AA00-2BD2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE XF204IRT (6GK5204-0BA00-2BF2)",
"product_id": "CSAFPID-0072",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2BF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204IRT (6GK5204-0BA00-2BF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE XF206-1 (6GK5206-1BC00-2AF2)",
"product_id": "CSAFPID-0073",
"product_identification_helper": {
"model_numbers": [
"6GK5206-1BC00-2AF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF206-1 (6GK5206-1BC00-2AF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE XF208 (6GK5208-0BA00-2AF2)",
"product_id": "CSAFPID-0074",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA00-2AF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF208 (6GK5208-0BA00-2AF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)",
"product_id": "CSAFPID-0075",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-2ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)",
"product_id": "CSAFPID-0076",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-2ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)",
"product_id": "CSAFPID-0077",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-2JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)",
"product_id": "CSAFPID-0078",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-2JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)",
"product_id": "CSAFPID-0079",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-4ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)",
"product_id": "CSAFPID-0080",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-4ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)",
"product_id": "CSAFPID-0081",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-4JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)",
"product_id": "CSAFPID-0082",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-4JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)",
"product_id": "CSAFPID-0083",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-1ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)",
"product_id": "CSAFPID-0084",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-1ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)",
"product_id": "CSAFPID-0085",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-1JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)",
"product_id": "CSAFPID-0086",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-1JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)",
"product_id": "CSAFPID-0087",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-3ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)",
"product_id": "CSAFPID-0088",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-3ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)",
"product_id": "CSAFPID-0089",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-3JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)",
"product_id": "CSAFPID-0090",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-3JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)",
"product_id": "CSAFPID-0091",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-1AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)",
"product_id": "CSAFPID-0092",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-1HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)",
"product_id": "CSAFPID-0093",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)",
"product_id": "CSAFPID-0094",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-3HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)",
"product_id": "CSAFPID-0095",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-1CR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)",
"product_id": "CSAFPID-0096",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-1AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)",
"product_id": "CSAFPID-0097",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-1AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)",
"product_id": "CSAFPID-0098",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-1HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)",
"product_id": "CSAFPID-0099",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-1HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)",
"product_id": "CSAFPID-0100",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)",
"product_id": "CSAFPID-0101",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)",
"product_id": "CSAFPID-0102",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-3HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)",
"product_id": "CSAFPID-0103",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-3HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)",
"product_id": "CSAFPID-0104",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-1CR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)",
"product_id": "CSAFPID-0105",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-1CR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)",
"product_id": "CSAFPID-0106",
"product_identification_helper": {
"model_numbers": [
"6AG1202-2BH00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)",
"product_id": "CSAFPID-0107",
"product_identification_helper": {
"model_numbers": [
"6AG1308-2FL10-4AA3"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-28895",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0031",
"CSAFPID-0030",
"CSAFPID-0029",
"CSAFPID-0028",
"CSAFPID-0027",
"CSAFPID-0026",
"CSAFPID-0025",
"CSAFPID-0024",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0041",
"CSAFPID-0040",
"CSAFPID-0039",
"CSAFPID-0038",
"CSAFPID-0037",
"CSAFPID-0036",
"CSAFPID-0035",
"CSAFPID-0034",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0095",
"CSAFPID-0106",
"CSAFPID-0107"
]
},
"remediations": [
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0031",
"CSAFPID-0030",
"CSAFPID-0029",
"CSAFPID-0028",
"CSAFPID-0027",
"CSAFPID-0026",
"CSAFPID-0025",
"CSAFPID-0024",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0041",
"CSAFPID-0040",
"CSAFPID-0039",
"CSAFPID-0038",
"CSAFPID-0037",
"CSAFPID-0036",
"CSAFPID-0035",
"CSAFPID-0034",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0095",
"CSAFPID-0107"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.2.6 or later version",
"product_ids": [
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0073",
"CSAFPID-0074"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109811753/"
},
{
"category": "vendor_fix",
"details": "Update to V5.5.2 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0106"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817790/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0031",
"CSAFPID-0030",
"CSAFPID-0029",
"CSAFPID-0028",
"CSAFPID-0027",
"CSAFPID-0026",
"CSAFPID-0025",
"CSAFPID-0024",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0041",
"CSAFPID-0040",
"CSAFPID-0039",
"CSAFPID-0038",
"CSAFPID-0037",
"CSAFPID-0036",
"CSAFPID-0035",
"CSAFPID-0034",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0095",
"CSAFPID-0106",
"CSAFPID-0107"
]
}
],
"title": "CVE-2020-28895"
},
{
"cve": "CVE-2020-35198",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "The APIs cacheDmaMalloc()/cacheArchDmaMalloc()/mmap64() align the size of the requested buffer with the memory page size of the target platform. If the requested size is large enough to cause integer overflow by the alignment calculation, a valid pointer to a buffer that is smaller than the requested size is returned, opening the door to use for heap overflow attacks.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0031",
"CSAFPID-0030",
"CSAFPID-0029",
"CSAFPID-0028",
"CSAFPID-0027",
"CSAFPID-0026",
"CSAFPID-0025",
"CSAFPID-0024",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0041",
"CSAFPID-0040",
"CSAFPID-0039",
"CSAFPID-0038",
"CSAFPID-0037",
"CSAFPID-0036",
"CSAFPID-0035",
"CSAFPID-0034",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0095",
"CSAFPID-0106",
"CSAFPID-0107"
]
},
"remediations": [
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0031",
"CSAFPID-0030",
"CSAFPID-0029",
"CSAFPID-0028",
"CSAFPID-0027",
"CSAFPID-0026",
"CSAFPID-0025",
"CSAFPID-0024",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0041",
"CSAFPID-0040",
"CSAFPID-0039",
"CSAFPID-0038",
"CSAFPID-0037",
"CSAFPID-0036",
"CSAFPID-0035",
"CSAFPID-0034",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0095",
"CSAFPID-0107"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.2.6 or later version",
"product_ids": [
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0073",
"CSAFPID-0074"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109811753/"
},
{
"category": "vendor_fix",
"details": "Update to V5.5.2 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0106"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817790/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0031",
"CSAFPID-0030",
"CSAFPID-0029",
"CSAFPID-0028",
"CSAFPID-0027",
"CSAFPID-0026",
"CSAFPID-0025",
"CSAFPID-0024",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0041",
"CSAFPID-0040",
"CSAFPID-0039",
"CSAFPID-0038",
"CSAFPID-0037",
"CSAFPID-0036",
"CSAFPID-0035",
"CSAFPID-0034",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0095",
"CSAFPID-0106",
"CSAFPID-0107"
]
}
],
"title": "CVE-2020-35198"
}
]
}
ICSA-25-155-02
Vulnerability from csaf_cisa - Published: 2021-12-16 13:30 - Updated: 2025-05-27 12:30In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Relion 670 series version 2.2.5 revisions up to 2.2.5.1
Hitachi Energy / Relion 670
|
vers:all/>=2.2.5.0|<=2.2.5.1 |
Vendor Fix
|
|
|
Relion 670 series version 2.2.4 revisions up to 2.2.4.2
Hitachi Energy / Relion 670
|
vers:all/>=2.2.4.0|<=2.2.4.2 |
Vendor Fix
|
|
|
Relion 670 series version 2.2.3 revisions up to 2.2.3.4
Hitachi Energy / Relion 670
|
vers:all/>=2.2.3.0|<=2.2.3.4 |
Vendor Fix
|
|
|
Relion 670 series version 2.2.2 revisions up to 2.2.2.4
Hitachi Energy / Relion 670
|
vers:all/>=2.2.2.0|<=2.2.2.4 |
Vendor Fix
|
|
|
Relion 670 series version 2.2.1 revisions up to 2.2.1.7
Hitachi Energy / Relion 670
|
vers:all/>=2.2.1.0|<=2.2.1.7 |
Vendor Fix
|
|
|
Relion 670 series version 1.1 to 2.2.0 all revisions
Hitachi Energy / Relion 670
|
vers:all/>=1.1|<2.2.1 |
Mitigation
|
|
|
Relion 650 series version 2.2.5 revisions up to 2.2.5.1
Hitachi Energy / Relion 650
|
vers:all/>=2.2.5.0|<=2.2.5.1 |
Vendor Fix
|
|
|
Relion 650 series version 2.2.4 revisions up to 2.2.4.2
Hitachi Energy / Relion 650
|
vers:all/>=2.2.4.0|<=2.2.4.2 |
Vendor Fix
|
|
|
Relion 650 series version 2.2.1 revisions up to 2.2.1.7
Hitachi Energy / Relion 650
|
vers:all/>=2.2.1.0|<=2.2.1.7 |
Vendor Fix
|
|
|
Relion 650 series version 1.0 to 2.2.0 all revisions
Hitachi Energy / Relion 650
|
vers:all/>=1.0|<2.2.1 |
Mitigation
|
|
|
SAM-IO series version 2.2.5 revisions up to 2.2.5.1
Hitachi Energy / SAM-IO
|
vers:all/>=2.2.5.0|<=2.2.5.1 |
Vendor Fix
|
|
|
SAM-IO series version 2.2.1 revisions up to 2.2.1.7
Hitachi Energy / SAM-IO
|
vers:all/>=2.2.1.0|<=2.2.1.7 |
Vendor Fix
|
An issue was discovered in Wind River VxWorks 7. The memory al-locator has a possible integer overflow in calculating a memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Relion 670 series version 2.2.5 revisions up to 2.2.5.1
Hitachi Energy / Relion 670
|
vers:all/>=2.2.5.0|<=2.2.5.1 |
Vendor Fix
|
|
|
Relion 670 series version 2.2.4 revisions up to 2.2.4.2
Hitachi Energy / Relion 670
|
vers:all/>=2.2.4.0|<=2.2.4.2 |
Vendor Fix
|
|
|
Relion 670 series version 2.2.3 revisions up to 2.2.3.4
Hitachi Energy / Relion 670
|
vers:all/>=2.2.3.0|<=2.2.3.4 |
Vendor Fix
|
|
|
Relion 670 series version 2.2.2 revisions up to 2.2.2.4
Hitachi Energy / Relion 670
|
vers:all/>=2.2.2.0|<=2.2.2.4 |
Vendor Fix
|
|
|
Relion 670 series version 2.2.1 revisions up to 2.2.1.7
Hitachi Energy / Relion 670
|
vers:all/>=2.2.1.0|<=2.2.1.7 |
Vendor Fix
|
|
|
Relion 670 series version 1.1 to 2.2.0 all revisions
Hitachi Energy / Relion 670
|
vers:all/>=1.1|<2.2.1 |
Mitigation
|
|
|
Relion 650 series version 2.2.5 revisions up to 2.2.5.1
Hitachi Energy / Relion 650
|
vers:all/>=2.2.5.0|<=2.2.5.1 |
Vendor Fix
|
|
|
Relion 650 series version 2.2.4 revisions up to 2.2.4.2
Hitachi Energy / Relion 650
|
vers:all/>=2.2.4.0|<=2.2.4.2 |
Vendor Fix
|
|
|
Relion 650 series version 2.2.1 revisions up to 2.2.1.7
Hitachi Energy / Relion 650
|
vers:all/>=2.2.1.0|<=2.2.1.7 |
Vendor Fix
|
|
|
Relion 650 series version 1.0 to 2.2.0 all revisions
Hitachi Energy / Relion 650
|
vers:all/>=1.0|<2.2.1 |
Mitigation
|
|
|
SAM-IO series version 2.2.5 revisions up to 2.2.5.1
Hitachi Energy / SAM-IO
|
vers:all/>=2.2.5.0|<=2.2.5.1 |
Vendor Fix
|
|
|
SAM-IO series version 2.2.1 revisions up to 2.2.1.7
Hitachi Energy / SAM-IO
|
vers:all/>=2.2.1.0|<=2.2.1.7 |
Vendor Fix
|
{
"document": {
"acknowledgments": [
{
"organization": "Hitachi Energy PSIRT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"aggregate_severity": {
"namespace": "https://www.first.org/cvss/specification-document",
"text": "CRITICAL"
},
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "summary",
"text": "Hitachi Energy is aware of two critical memory allocation vulnerabilities (called BadAlloc [1] vulnerabilities) in the WindRiver VxWorks Operating Systems [2][3] that are used in our product versions listed in this advisory.\nAn attacker that exploits these vulnerabilities might bypass security controls to execute malicious code or cause a denial-of-service. For immediate mitigation/workaround information, please refer to the Mitigation Fac-tors/Workaround Section.\n\n[1] BadAlloc \u2013 Microsoft\u2019s Section 52 - https://msrc-blog.microsoft.com/2021/04/29/badalloc-memory-allo-cation-vulnerabilities-could-affect-wide-range-of-iot-and-ot-devices-in-industrial-medical-and-enterprise-networks/\n[2] Wind River VxWorks \u2013 CVE-2020-28895 Advisory - https://support2.windriver.com/in-dex.php?page=cve\u0026on=view\u0026id=CVE-2020-28895\n[3] Wind River VxWorks \u2013 CVE-2020-35198 Advisory - https://support2.windriver.com/in-dex.php?page=cve\u0026on=view\u0026id=CVE-2020-35198",
"title": "Summary"
},
{
"category": "legal_disclaimer",
"text": "The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warran-ties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.",
"title": "Notice"
},
{
"category": "general",
"text": "For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers.",
"title": "Support"
},
{
"category": "general",
"text": "Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.",
"title": "General Mitigation Factors"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000070 from a direct conversion of their vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Switzerland",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-25-155-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-155-02.json"
},
{
"category": "self",
"summary": "Cybersecurity Advisory - BadAlloc \u2013 Memory Allocation Vulnerabilities in Hitachi Energy Relion 670, 650 series and SAM600-IO Product",
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000070\u0026languageCode=en\u0026Preview=true"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-155-02 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-155-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Hitachi Energy Relion 670 650 series and SAM600-IO Product",
"tracking": {
"current_release_date": "2025-05-27T12:30:00.000000Z",
"generator": {
"date": "2025-06-05T16:55:18.347501Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-155-02",
"initial_release_date": "2021-12-16T13:30:00.000000Z",
"revision_history": [
{
"date": "2021-12-16T13:30:00.000000Z",
"number": "1",
"summary": "Initial version."
},
{
"date": "2025-05-27T12:30:00.000000Z",
"number": "2",
"summary": "Update to Recommended Actions table with fixed versions"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=2.2.5.0|\u003c=2.2.5.1",
"product": {
"name": "Relion 670 series version 2.2.5 revisions up to 2.2.5.1",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Relion 670"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=2.2.4.0|\u003c=2.2.4.2",
"product": {
"name": "Relion 670 series version 2.2.4 revisions up to 2.2.4.2",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Relion 670"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=2.2.3.0|\u003c=2.2.3.4",
"product": {
"name": "Relion 670 series version 2.2.3 revisions up to 2.2.3.4",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Relion 670"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=2.2.2.0|\u003c=2.2.2.4",
"product": {
"name": "Relion 670 series version 2.2.2 revisions up to 2.2.2.4",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "Relion 670"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=2.2.1.0|\u003c=2.2.1.7",
"product": {
"name": "Relion 670 series version 2.2.1 revisions up to 2.2.1.7",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "Relion 670"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=1.1|\u003c2.2.1",
"product": {
"name": "Relion 670 series version 1.1 to 2.2.0 all revisions",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "Relion 670"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=2.2.5.0|\u003c=2.2.5.1",
"product": {
"name": "Relion 650 series version 2.2.5 revisions up to 2.2.5.1",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "Relion 650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=2.2.4.0|\u003c=2.2.4.2",
"product": {
"name": "Relion 650 series version 2.2.4 revisions up to 2.2.4.2",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "Relion 650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=2.2.1.0|\u003c=2.2.1.7",
"product": {
"name": "Relion 650 series version 2.2.1 revisions up to 2.2.1.7",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "Relion 650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=1.0|\u003c2.2.1",
"product": {
"name": "Relion 650 series version 1.0 to 2.2.0 all revisions",
"product_id": "CSAFPID-0010"
}
}
],
"category": "product_name",
"name": "Relion 650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=2.2.5.0|\u003c=2.2.5.1",
"product": {
"name": "SAM-IO series version 2.2.5 revisions up to 2.2.5.1",
"product_id": "CSAFPID-0011"
}
}
],
"category": "product_name",
"name": "SAM-IO"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=2.2.1.0|\u003c=2.2.1.7",
"product": {
"name": "SAM-IO series version 2.2.1 revisions up to 2.2.1.7",
"product_id": "CSAFPID-0012"
}
}
],
"category": "product_name",
"name": "SAM-IO"
}
],
"category": "vendor",
"name": "Hitachi Energy"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-28895",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "description",
"text": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012"
]
},
"references": [
{
"category": "external",
"summary": "NVD CVE Detail",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-28895"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to 2.2.5.2 version or latest",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0007",
"CSAFPID-0011"
]
},
{
"category": "vendor_fix",
"details": "Update to 2.2.4.3 version or latest",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0008"
]
},
{
"category": "vendor_fix",
"details": "Update to 2.2.3.5 version or latest",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to 2.2.2.5 version or latest",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "vendor_fix",
"details": "Update to 2.2.1.8 version or latest",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0009",
"CSAFPID-0012"
]
},
{
"category": "mitigation",
"details": "Refer to the Mitigation Factors/Workaround Section for the current mitigation strategy.",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0010"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"environmentalScore": 7.3,
"environmentalSeverity": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.3,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012"
]
}
],
"title": "CVE-2020-28895"
},
{
"cve": "CVE-2020-35198",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "description",
"text": "An issue was discovered in Wind River VxWorks 7. The memory al-locator has a possible integer overflow in calculating a memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012"
]
},
"references": [
{
"category": "external",
"summary": "NVD CVE Detail",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-35198"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to 2.2.5.2 version or latest",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0007",
"CSAFPID-0011"
]
},
{
"category": "vendor_fix",
"details": "Update to 2.2.4.3 version or latest",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0008"
]
},
{
"category": "vendor_fix",
"details": "Update to 2.2.3.5 version or latest",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to 2.2.2.5 version or latest",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "vendor_fix",
"details": "Update to 2.2.1.8 version or latest",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0009",
"CSAFPID-0012"
]
},
{
"category": "mitigation",
"details": "Refer to the Mitigation Factors/Workaround Section for the current mitigation strategy.",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0010"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012"
]
}
],
"title": "CVE-2020-35198"
}
]
}
ICSA-25-252-09
Vulnerability from csaf_cisa - Published: 2025-09-09 06:00 - Updated: 2025-09-09 06:00{
"document": {
"acknowledgments": [
{
"organization": "Rockwell Automation",
"summary": "reporting this vulnerability to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could allow an attacker to cause a memory corruption on the product.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "United States",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Do not click web links or open attachments in unsolicited email messages.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-25-252-09 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-252-09.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-25-252-09 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-252-09"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Rockwell Automation 1783-NATR",
"tracking": {
"current_release_date": "2025-09-09T06:00:00.000000Z",
"generator": {
"date": "2025-09-09T14:51:38.306575Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-252-09",
"initial_release_date": "2025-09-09T06:00:00.000000Z",
"revision_history": [
{
"date": "2025-09-09T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.007",
"product": {
"name": "Rockwell Automation 1783-NATR: \u003c1.007",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "1783-NATR"
}
],
"category": "vendor",
"name": "Rockwell Automation"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-28895",
"cwe": {
"id": "CWE-1103",
"name": "Use of Platform-Dependent Third Party Components"
},
"notes": [
{
"category": "summary",
"text": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Rockwell Automation released a product update addressing this vulnerability:",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Version 1.007",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Users of the affected software unable to upgrade to one of the corrected versions should follow Rockwell Automation\u0027s security best practices.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
SEVD-2021-313-05
Vulnerability from csaf_se - Published: 2021-11-09 05:00 - Updated: 2025-09-09 04:00An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Easergy C5x Version 1.0.5
Schneider Electric / Easergy
|
1.0.5 | ||
|
Schneider Electric Easergy MiCOM P30 Version 675 and later
Schneider Electric / Easergy MiCOM P30
|
>=675 | ||
|
Schneider Electric Easergy MiCOM P30 Version 676.701
Schneider Electric / Easergy MiCOM P30
|
P638
|
676.701 | |
|
Schneider Electric Eurotherm EPC2000 Version 4.03
Schneider Electric / Eurotherm / EPC2000
|
4.03 | ||
|
Schneider Electric Eurotherm EPC3000 Version 5.20
Schneider Electric / Eurotherm / EPC3000
|
5.20 | ||
| Unresolved product id: 18 | — | ||
| Unresolved product id: 21 | — | ||
|
Schneider Electric Eurotherm E+PLC400 Version 1.4.0.0
Schneider Electric / Eurotherm / E+PLC400
|
1.4.0.0 | ||
|
Schneider Electric Eurotherm Eycon 10/20 Visual Supervisor Version 7.3
Schneider Electric / Eurotherm / Eycon 10/20 Visual Supervisor
|
7.3 | ||
|
Schneider Electric Eurotherm T2550 PAC Version 8.2
Schneider Electric / Eurotherm / T2550 PAC
|
8.2 | ||
|
Schneider Electric Eurotherm T2750 PAC Version 6.3
Schneider Electric / Eurotherm / T2750 PAC
|
6.3 | ||
| Unresolved product id: 38 | — | ||
| Unresolved product id: 39 | — | ||
| Unresolved product id: 41 | — | ||
| Unresolved product id: 42 | — | ||
| Unresolved product id: 44 | — | ||
| Unresolved product id: 45 | — | ||
| Unresolved product id: 51 | — | ||
| Unresolved product id: 52 | — | ||
| Unresolved product id: 58 | — | ||
| Unresolved product id: 59 | — | ||
|
Schneider Electric MiCOM C264 Version B5.118
Schneider Electric / MiCOM C264
|
B5.118 | ||
|
Schneider Electric MiCOM C264 Version D1.92
Schneider Electric / MiCOM C264
|
D1.92 | ||
|
Schneider Electric MiCOM C264 Version D4.38
Schneider Electric / MiCOM C264
|
D4.38 | ||
|
Schneider Electric MiCOM C264 Version D5.25I
Schneider Electric / MiCOM C264
|
D5.25I | ||
|
Schneider Electric MiCOM C264 Version D6.18
Schneider Electric / MiCOM C264
|
D6.18 | ||
|
Schneider Electric Modicon M241 Logic Controllers Version 5.1.9.34 or greater
Schneider Electric / Modicon M241 Logic Controllers
|
>=5.1.9.34 | ||
|
Schneider Electric Modicon M251 Logic Controllers Version 5.1.9.34 or greater
Schneider Electric / Modicon M251 Logic Controllers
|
>=5.1.9.34 | ||
|
Schneider Electric Modicon M262 Logic Controllers Version 5.1.6.1 or greater
Schneider Electric / Modicon M262 Logic Controllers
|
>=5.1.6.1 | ||
|
Schneider Electric Modicon M258 Logic Controllers Version 5.0.4.18
Schneider Electric / Modicon M258 Logic Controllers
|
5.0.4.18 | ||
|
Schneider Electric Modicon LMC058 Logic Controllers Version 5.0.4.18
Schneider Electric / Modicon LMC058 Logic Controllers
|
5.0.4.18 | ||
|
Schneider Electric Modicon M340 Module BMXNOC0401 Version v2.11
Schneider Electric / Modicon M340 Module / BMXNOC0401
|
2.11 | ||
|
Schneider Electric Modicon M340 Ethernet Communication Modules BMXNOE0100 (H) Version SV3.50
Schneider Electric / Modicon M340 Ethernet Communication Modules / BMXNOE0100 (H)
|
SV3.50 | ||
|
Schneider Electric Modicon M340 Ethernet Communication Modules BMXNOE0110 (H) Version SV6.70
Schneider Electric / Modicon M340 Ethernet Communication Modules / BMXNOE0110 (H)
|
SV6.70 | ||
|
Schneider Electric Modicon M340 Module BMXNOR0200 (H) RTU Version 1.7 IR24
Schneider Electric / Modicon M340 Module / BMXNOR0200 (H) RTU
|
1.7 IR24 | ||
|
Schneider Electric Modicon M340 CPU Version 3.50
Schneider Electric / Modicon M340 CPU
|
BMXP34*
|
3.50 | |
|
Schneider Electric Modicon M580 CPU Version SV4.10
Schneider Electric / Modicon M580 CPU
|
BMEP*BMEH*
|
SV4.10 | |
|
Schneider Electric Modicon M580 Ethernet Communication Modules BMENOC0301 Version SV2.21
Schneider Electric / Modicon M580 Ethernet Communication Modules / BMENOC0301
|
SV2.21 | ||
|
Schneider Electric Modicon M580 Ethernet Communication Modules BMENOC0311 Version SV2.21
Schneider Electric / Modicon M580 Ethernet Communication Modules / BMENOC0311
|
SV2.21 | ||
|
Schneider Electric Modicon M580 NOC Control BMENOC0321 Version SV1.09
Schneider Electric / Modicon M580 NOC Control / BMENOC0321
|
SV1.09 | ||
|
Schneider Electric HART X80 Module BMEAHI0812 Version SV1.5
Schneider Electric / HART IO X80 Module / BMEAHI0812
|
SV1.5 | ||
|
Schneider Electric HART X80 Module BMEAHO0412 Version SV1.5
Schneider Electric / HART IO X80 Module / BMEAHO0412
|
SV1.5 | ||
|
Schneider Electric Modicon MC80 Controller Version v1.8
Schneider Electric / Modicon MC80 Controller
|
BMKC80
|
1.8 | |
|
Schneider Electric Modicon Momentum Unity M1E Processor Version SV2.6
Schneider Electric / Modicon Momentum Unity M1E Processor
|
171CBU*
|
SV2.6 | |
|
Schneider Electric Modicon X80 Module BMXNOM0200 Version 1.60
Schneider Electric / Modicon X80 Module / BMXNOM0200
|
1.60 | ||
|
Schneider Electric Modicon X80 Module BMENOS0300 Version 1.04
Schneider Electric / Modicon X80 Module / BMENOS0300
|
1.04 | ||
|
Schneider Electric Eurotherm nanodac Version 10.02
Schneider Electric / Eurotherm / nanodac
|
10.02 | ||
|
Schneider Electric PacDrive Eco Logic Controllers Version 1.66.5.1
Schneider Electric / PacDrive / PacDrive Eco Logic Controllers
|
1.66.5.1 | ||
|
Schneider Electric PacDrive Pro Logic Controllers Version 1.66.5.1
Schneider Electric / PacDrive / PacDrive Pro Logic Controllers
|
1.66.5.1 | ||
|
Schneider Electric PacDrive Pro2 Logic Controllers Version 1.66.5.1
Schneider Electric / PacDrive / PacDrive Pro2 Logic Controllers
|
1.66.5.1 | ||
|
Schneider Electric PowerLogic ION7400 Version 3.1
Schneider Electric / PowerLogic / ION7400
|
3.1 | ||
|
Schneider Electric PowerLogic PM8000 Version 3.1
Schneider Electric / PowerLogic / PM8000
|
3.1 | ||
|
Schneider Electric PowerLogic ION9000 Version 3.1
Schneider Electric / PowerLogic / ION9000
|
3.1 | ||
| Unresolved product id: 156 | — | ||
| Unresolved product id: 157 | — | ||
| Unresolved product id: 158 | — | ||
| Unresolved product id: 159 | — | ||
| Unresolved product id: 160 | — | ||
| Unresolved product id: 162 | — | ||
| Unresolved product id: 165 | — | ||
| Unresolved product id: 166 | — | ||
|
Schneider Electric SCD6000 Industrial RTU Version SY-1101207_N
Schneider Electric / SCD6000 Industrial RTU
|
SY-1101207_N | ||
|
Schneider Electric SAGE RTU CPU C3414 Version C3414-500-S02K5_P5
Schneider Electric / SAGE RTU CPU C3414
|
C3414-500-S02K5_P5 | ||
|
Schneider Electric Eurotherm Versadac Version 2.43
Schneider Electric / Eurotherm / Versadac Scalable Data Recorder
|
2.43 | ||
|
Schneider Electric BMECRA31210 Version SV02.80
Schneider Electric / BMECRA31210
|
SV02.80 | ||
|
Schneider Electric BMXCRA31200 Version SV02.80
Schneider Electric / BMXCRA31200
|
SV02.80 | ||
|
Schneider Electric BMXCRA31210 Version SV02.80
Schneider Electric / BMXCRA31210
|
SV02.80 | ||
|
Schneider Electric 140CRA31200 (Quantum RIO Drop) Version 02.80
Schneider Electric / 140CRA31200 (Quantum RIO Drop)
|
02.80 | ||
|
Schneider Electric 140CRA31908 (M580 Quantum S908 RIO Drop Adapter) Version 02.80
Schneider Electric / 140CRA31908 (M580 Quantum S908 RIO Drop Adapter)
|
02.80 | ||
|
Schneider Electric BMENOP0300 Version SV2.6
Schneider Electric / BMENOP0300
|
SV2.6 | ||
| Unresolved product id: 202 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Easergy C5x Versions prior to 1.0.5
Schneider Electric / Easergy
|
C52C53
|
<1.0.5 |
Vendor Fix
|
|
Schneider Electric Easergy MiCOM P30 v660 to v674
Schneider Electric / Easergy MiCOM P30
|
P138P139P436P437P438P439P532P631P632P633P634C434
|
>=660|<=674 |
Vendor Fix
|
|
Schneider Electric Easergy MiCOM P30 v660 to v674
Schneider Electric / Easergy MiCOM P30
|
P638
|
>=660|<=674 |
Vendor Fix
|
|
Schneider Electric Easergy MiCOM P30 v660 to v674
Schneider Electric / Easergy MiCOM P30
|
P132P433P435
|
>=660|<=674 |
Mitigation
|
|
Schneider Electric Eurotherm EPC2000 Versions prior to v4.03
Schneider Electric / Eurotherm / EPC2000
|
<4.03 |
Vendor Fix
fix
|
|
|
Schneider Electric Eurotherm EPC3000 Versions prior to v5.20
Schneider Electric / Eurotherm / EPC3000
|
<5.20 |
Vendor Fix
fix
|
|
| Unresolved product id: 17 | — |
Vendor Fix
|
|
| Unresolved product id: 20 | — |
Vendor Fix
|
|
|
Schneider Electric Eurotherm E+PLC100 All Versions
Schneider Electric / Eurotherm / E+PLC100
|
vers:all/* |
No Fix Planned
Mitigation
|
|
|
Schneider Electric Eurotherm E+PLC400 Versions prior to v1.4.0.0
Schneider Electric / Eurotherm / E+PLC400
|
<1.4.0.0 |
Vendor Fix
|
|
|
Schneider Electric Eurotherm Eycon 10/20 Visual Supervisor Versions prior to 7.3
Schneider Electric / Eurotherm / Eycon 10/20 Visual Supervisor
|
<7.3 |
Vendor Fix
fix
|
|
|
Schneider Electric Eurotherm T2550 PAC Versions prior to 8.2
Schneider Electric / Eurotherm / T2550 PAC
|
<8.2 |
Vendor Fix
fix
|
|
|
Schneider Electric Eurotherm T2750 PAC Versions prior to 6.3
Schneider Electric / Eurotherm / T2750 PAC
|
<6.3 |
Vendor Fix
fix
|
|
| Unresolved product id: 37 | — |
Vendor Fix
|
|
| Unresolved product id: 40 | — |
Vendor Fix
|
|
| Unresolved product id: 43 | — |
Vendor Fix
|
|
| Unresolved product id: 50 | — |
Vendor Fix
|
|
| Unresolved product id: 57 | — |
Vendor Fix
fix
|
|
|
Schneider Electric MiCOM C264 Versions greater than or equal to B5.x and prior to B5.118
Schneider Electric / MiCOM C264
|
>=B5.x|<B5.118 |
Vendor Fix
|
|
|
Schneider Electric MiCOM C264 Versions greater than or equal to D1.x and prior to D1.92
Schneider Electric / MiCOM C264
|
>=D1.x|<D1.92 |
Vendor Fix
|
|
|
Schneider Electric MiCOM C264 Versions greater than or equal to D4.x and prior to D4.38
Schneider Electric / MiCOM C264
|
>=D4.x|<D4.38 |
Vendor Fix
|
|
|
Schneider Electric MiCOM C264 Versions greater than or equal to D5.x and prior to D5.25I
Schneider Electric / MiCOM C264
|
>=D5.x|<D5.25I |
Vendor Fix
|
|
|
Schneider Electric MiCOM C264 Versions greater than or equal to D6.x and prior to D6.18
Schneider Electric / MiCOM C264
|
>=D6.x|<D6.18 |
Vendor Fix
|
|
|
Schneider Electric Modicon M241 Logic Controllers Versions prior to 5.1.9.34
Schneider Electric / Modicon M241 Logic Controllers
|
<5.1.9.34 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M251 Logic Controllers Versions prior to 5.1.9.34
Schneider Electric / Modicon M251 Logic Controllers
|
<5.1.9.34 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M262 Logic Controllers Versions prior to 5.1.6.1
Schneider Electric / Modicon M262 Logic Controllers
|
<5.1.6.1 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M258 Logic Controllers Versions prior to 5.0.4.18
Schneider Electric / Modicon M258 Logic Controllers
|
<5.0.4.18 |
Vendor Fix
|
|
|
Schneider Electric Modicon LMC058 Logic Controllers Versions prior to 5.0.4.18
Schneider Electric / Modicon LMC058 Logic Controllers
|
<5.0.4.18 |
Vendor Fix
|
|
|
Schneider Electric Modicon M340 Module BMXNOC0401 Versions prior to v2.11
Schneider Electric / Modicon M340 Module / BMXNOC0401
|
<2.11 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M340 Ethernet Communication Modules BMXNOE0100 (H) Versions prior to SV3.50
Schneider Electric / Modicon M340 Ethernet Communication Modules / BMXNOE0100 (H)
|
<SV3.50 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M340 Ethernet Communication Modules BMXNOE0110 (H) Versions prior to SV6.70
Schneider Electric / Modicon M340 Ethernet Communication Modules / BMXNOE0110 (H)
|
<SV6.70 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M340 Module BMXNOR0200 (H) RTU Versions prior to v1.7 IR24
Schneider Electric / Modicon M340 Module / BMXNOR0200 (H) RTU
|
<1.7 IR24 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M340 CPU Versions prior to 3.50
Schneider Electric / Modicon M340 CPU
|
BMXP34*
|
<3.50 |
Vendor Fix
fix
|
|
Schneider Electric Modicon M580 CPU Versions prior to SV4.10
Schneider Electric / Modicon M580 CPU
|
BMEP*BMEH*
|
<SV4.10 |
Vendor Fix
fix
|
|
Schneider Electric Modicon M580 CPU Safety Versions prior to SV4.21
Schneider Electric / Modicon M580 CPU Safety
|
BMEP58*SBMEH58*S
|
<SV4.21 |
Vendor Fix
fix
|
|
Schneider Electric Modicon M580 Ethernet Communication Modules BMENOC0301 Versions prior to SV2.21
Schneider Electric / Modicon M580 Ethernet Communication Modules / BMENOC0301
|
<SV2.21 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M580 Ethernet Communication Modules BMENOC0311 Versions prior to SV2.21
Schneider Electric / Modicon M580 Ethernet Communication Modules / BMENOC0311
|
<SV2.21 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M580 NOC Control BMENOC0321 Versions prior to SV1.09
Schneider Electric / Modicon M580 NOC Control / BMENOC0321
|
<SV1.09 |
Vendor Fix
fix
|
|
|
Schneider Electric HART X80 Module BMEAHI0812 Versions prior to SV1.5
Schneider Electric / HART IO X80 Module / BMEAHI0812
|
<SV1.5 |
Vendor Fix
fix
|
|
|
Schneider Electric HART X80 Module BMEAHO0412 Versions prior to SV1.5
Schneider Electric / HART IO X80 Module / BMEAHO0412
|
<SV1.5 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon MC80 Controller Versions prior to v1.8
Schneider Electric / Modicon MC80 Controller
|
BMKC8*
|
<1.8 |
Vendor Fix
fix
|
|
Schneider Electric Modicon Momentum ENT All Versions
Schneider Electric / Modicon Momentum ENT
|
170ENT11*
|
vers:all/* |
Mitigation
|
|
Schneider Electric Modicon Momentum Unity M1E Processor Versions prior to SV2.6
Schneider Electric / Modicon Momentum Unity M1E Processor
|
171CBU*
|
<SV2.6 |
Vendor Fix
fix
|
|
Schneider Electric Modicon Quantum CPU and Communication Modules All Versions
Schneider Electric / Modicon Quantum CPU and Communication Modules
|
vers:all/* |
No Fix Planned
Mitigation
|
|
|
Schneider Electric Modicon Premium CPU and Communication Modules All Versions
Schneider Electric / Modicon Premium CPU and Communication Modules
|
vers:all/* |
No Fix Planned
Mitigation
|
|
|
Schneider Electric Modicon X80 Module BMXNOM0200 Versions prior to v1.60
Schneider Electric / Modicon X80 Module / BMXNOM0200
|
<1.60 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon X80 Module BMENOS0300 Versions prior to v1.04
Schneider Electric / Modicon X80 Module / BMENOS0300
|
<1.04 |
Vendor Fix
fix
|
|
|
Schneider Electric Eurotherm nanodac Versions prior to 10.02
Schneider Electric / Eurotherm / nanodac
|
<10.02 |
Vendor Fix
fix
|
|
|
Schneider Electric PacDrive Eco Logic Controllers Versions prior to 1.66.5.1
Schneider Electric / PacDrive / PacDrive Eco Logic Controllers
|
<1.66.5.1 |
Vendor Fix
|
|
|
Schneider Electric PacDrive Pro Logic Controllers Versions prior to 1.66.5.1
Schneider Electric / PacDrive / PacDrive Pro Logic Controllers
|
<1.66.5.1 |
Vendor Fix
|
|
|
Schneider Electric PacDrive Pro2 Logic Controllers Versions prior to 1.66.5.1
Schneider Electric / PacDrive / PacDrive Pro2 Logic Controllers
|
<1.66.5.1 |
Vendor Fix
|
|
|
Schneider Electric PacDrive M Logic Controller All Versions
Schneider Electric / PacDrive / PacDrive M Logic Controller
|
vers:all/* |
No Fix Planned
Mitigation
|
|
|
Schneider Electric PowerLogic ION7400 Versions prior to v3.1
Schneider Electric / PowerLogic / ION7400
|
<3.1 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric PowerLogic PM8000 Versions prior to v3.1
Schneider Electric / PowerLogic / PM8000
|
<3.1 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric PowerLogic ION9000 Versions prior to v3.1
Schneider Electric / PowerLogic / ION9000
|
<3.1 |
Vendor Fix
fix
Mitigation
|
|
| Unresolved product id: 151 | — |
Vendor Fix
fix
|
|
| Unresolved product id: 152 | — |
Vendor Fix
fix
|
|
| Unresolved product id: 153 | — |
Vendor Fix
fix
|
|
| Unresolved product id: 154 | — |
Vendor Fix
fix
|
|
| Unresolved product id: 155 | — |
Vendor Fix
fix
|
|
| Unresolved product id: 161 | — |
Vendor Fix
fix
|
|
| Unresolved product id: 163 | — |
Vendor Fix
fix
|
|
| Unresolved product id: 164 | — |
Vendor Fix
fix
|
|
|
Schneider Electric Profibus Remote Master TCSEGPA23F14F All Versions
Schneider Electric / Profibus Remote Master / TCSEGPA23F14F
|
vers:all/* |
Mitigation
fix
|
|
|
Schneider Electric Profibus Remote Master BMECXM0100 All Versions
Schneider Electric / Profibus Remote Master / BMECXM0100
|
vers:all/* |
Mitigation
fix
|
|
|
Schneider Electric SCD6000 Industrial RTU Versions prior to SY-1101207_N
Schneider Electric / SCD6000 Industrial RTU
|
<SY-1101207_N |
Vendor Fix
|
|
|
Schneider Electric SAGE RTU CPU C3414 Versions prior to C3414-500-S02K5_P5
Schneider Electric / SAGE RTU CPU C3414
|
<C3414-500-S02K5_P5 |
Vendor Fix
fix
|
|
|
Schneider Electric Eurotherm Versadac Scalable Data Recorder Versions prior to 2.43
Schneider Electric / Eurotherm / Versadac Scalable Data Recorder
|
<2.43 |
Vendor Fix
fix
|
|
|
Schneider Electric BMECRA31210 Versions prior to SV02.80
Schneider Electric / BMECRA31210
|
<SV02.80 |
Vendor Fix
fix
|
|
|
Schneider Electric BMXCRA31200 Versions prior to SV02.80
Schneider Electric / BMXCRA31200
|
<SV02.80 |
Vendor Fix
fix
|
|
|
Schneider Electric BMXCRA31210 Versions prior to SV02.80
Schneider Electric / BMXCRA31210
|
<SV02.80 |
Vendor Fix
fix
|
|
|
Schneider Electric 140CRA31200 (Quantum RIO Drop) Versions prior to V02.80
Schneider Electric / 140CRA31200 (Quantum RIO Drop)
|
<02.80 |
Vendor Fix
fix
|
|
|
Schneider Electric 140CRA31908 (M580 Quantum S908 RIO Drop Adapter) Versions prior to V02.80
Schneider Electric / 140CRA31908 (M580 Quantum S908 RIO Drop Adapter)
|
<02.80 |
Vendor Fix
fix
|
|
|
Schneider Electric BMENOP0300 Versions prior to SV2.6
Schneider Electric / BMENOP0300
|
<02.80 |
Vendor Fix
fix
|
|
|
Schneider Electric BMXNGD0100 All Versions
Schneider Electric / BMXNGD0100
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Easergy MiCOM P30 v660 to v674
Schneider Electric / Easergy MiCOM P30
|
Px36Px38
|
>=660|<=674 |
Mitigation
|
|
Schneider Electric EPack All Versions
Schneider Electric / EPack
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric HMISTO5 Series All Versions
Schneider Electric / HMISTO5 Series
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Modicon LMC078 All Versions
Schneider Electric / Modicon LMC078
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Pro-face GP4100 Series All Versions
Schneider Electric / Pro-face / GP4100 Series
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Pro-face GP4000E Series All Versions
Schneider Electric / Pro-face / GP4000E Series
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Pro-face GP4000M Series All Versions
Schneider Electric / Pro-face / GP4000M Series
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Eurotherm 6100A All Versions
Schneider Electric / Eurotherm / 6100A
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Eurotherm 6180A All Versions
Schneider Electric / Eurotherm / 6180A
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Eurotherm 6100XIO All Versions
Schneider Electric / Eurotherm / 6100XIO
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Eurotherm 6180XIO All Versions
Schneider Electric / Eurotherm / 6180XIO
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Eurotherm AeroDAQ All Versions
Schneider Electric / Eurotherm / AeroDAQ
|
vers:all/* |
Mitigation
|
In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Easergy C5x Version 1.0.5
Schneider Electric / Easergy
|
1.0.5 | ||
|
Schneider Electric Easergy MiCOM P30 Version 675 and later
Schneider Electric / Easergy MiCOM P30
|
>=675 | ||
|
Schneider Electric Easergy MiCOM P30 Version 676.701
Schneider Electric / Easergy MiCOM P30
|
P638
|
676.701 | |
|
Schneider Electric Easergy P5 Version 01.401.101
Schneider Electric / Easergy P5
|
01.401.101 | ||
|
Schneider Electric Eurotherm EPC2000 Version 4.03
Schneider Electric / Eurotherm / EPC2000
|
4.03 | ||
|
Schneider Electric Eurotherm EPC3000 Version 5.20
Schneider Electric / Eurotherm / EPC3000
|
5.20 | ||
| Unresolved product id: 18 | — | ||
| Unresolved product id: 21 | — | ||
|
Schneider Electric Eurotherm E+PLC400 Version 1.4.0.0
Schneider Electric / Eurotherm / E+PLC400
|
1.4.0.0 | ||
|
Schneider Electric Eurotherm Eycon 10/20 Visual Supervisor Version 7.3
Schneider Electric / Eurotherm / Eycon 10/20 Visual Supervisor
|
7.3 | ||
|
Schneider Electric Eurotherm T2550 PAC Version 8.2
Schneider Electric / Eurotherm / T2550 PAC
|
8.2 | ||
|
Schneider Electric Eurotherm T2750 PAC Version 6.3
Schneider Electric / Eurotherm / T2750 PAC
|
6.3 | ||
| Unresolved product id: 38 | — | ||
| Unresolved product id: 39 | — | ||
| Unresolved product id: 41 | — | ||
| Unresolved product id: 42 | — | ||
| Unresolved product id: 44 | — | ||
| Unresolved product id: 45 | — | ||
| Unresolved product id: 51 | — | ||
| Unresolved product id: 52 | — | ||
| Unresolved product id: 58 | — | ||
| Unresolved product id: 59 | — | ||
|
Schneider Electric MiCOM C264 Version B5.118
Schneider Electric / MiCOM C264
|
B5.118 | ||
|
Schneider Electric MiCOM C264 Version D1.92
Schneider Electric / MiCOM C264
|
D1.92 | ||
|
Schneider Electric MiCOM C264 Version D4.38
Schneider Electric / MiCOM C264
|
D4.38 | ||
|
Schneider Electric MiCOM C264 Version D5.25I
Schneider Electric / MiCOM C264
|
D5.25I | ||
|
Schneider Electric MiCOM C264 Version D6.18
Schneider Electric / MiCOM C264
|
D6.18 | ||
|
Schneider Electric Modicon M241 Logic Controllers Version 5.1.9.34 or greater
Schneider Electric / Modicon M241 Logic Controllers
|
>=5.1.9.34 | ||
|
Schneider Electric Modicon M251 Logic Controllers Version 5.1.9.34 or greater
Schneider Electric / Modicon M251 Logic Controllers
|
>=5.1.9.34 | ||
|
Schneider Electric Modicon M262 Logic Controllers Version 5.1.6.1 or greater
Schneider Electric / Modicon M262 Logic Controllers
|
>=5.1.6.1 | ||
|
Schneider Electric Modicon M258 Logic Controllers Version 5.0.4.18
Schneider Electric / Modicon M258 Logic Controllers
|
5.0.4.18 | ||
|
Schneider Electric Modicon LMC058 Logic Controllers Version 5.0.4.18
Schneider Electric / Modicon LMC058 Logic Controllers
|
5.0.4.18 | ||
|
Schneider Electric Modicon M340 Module BMXNOC0401 Version v2.11
Schneider Electric / Modicon M340 Module / BMXNOC0401
|
2.11 | ||
|
Schneider Electric Modicon M340 Ethernet Communication Modules BMXNOE0100 (H) Version SV3.50
Schneider Electric / Modicon M340 Ethernet Communication Modules / BMXNOE0100 (H)
|
SV3.50 | ||
|
Schneider Electric Modicon M340 Ethernet Communication Modules BMXNOE0110 (H) Version SV6.70
Schneider Electric / Modicon M340 Ethernet Communication Modules / BMXNOE0110 (H)
|
SV6.70 | ||
|
Schneider Electric Modicon M340 Module BMXNOR0200 (H) RTU Version 1.7 IR24
Schneider Electric / Modicon M340 Module / BMXNOR0200 (H) RTU
|
1.7 IR24 | ||
|
Schneider Electric Modicon M340 CPU Version 3.50
Schneider Electric / Modicon M340 CPU
|
BMXP34*
|
3.50 | |
|
Schneider Electric Modicon M580 CPU Version SV4.10
Schneider Electric / Modicon M580 CPU
|
BMEP*BMEH*
|
SV4.10 | |
|
Schneider Electric Modicon M580 Ethernet Communication Modules BMENOC0301 Version SV2.21
Schneider Electric / Modicon M580 Ethernet Communication Modules / BMENOC0301
|
SV2.21 | ||
|
Schneider Electric Modicon M580 Ethernet Communication Modules BMENOC0311 Version SV2.21
Schneider Electric / Modicon M580 Ethernet Communication Modules / BMENOC0311
|
SV2.21 | ||
|
Schneider Electric Modicon M580 NOC Control BMENOC0321 Version SV1.09
Schneider Electric / Modicon M580 NOC Control / BMENOC0321
|
SV1.09 | ||
|
Schneider Electric HART X80 Module BMEAHI0812 Version SV1.5
Schneider Electric / HART IO X80 Module / BMEAHI0812
|
SV1.5 | ||
|
Schneider Electric HART X80 Module BMEAHO0412 Version SV1.5
Schneider Electric / HART IO X80 Module / BMEAHO0412
|
SV1.5 | ||
|
Schneider Electric Modicon MC80 Controller Version v1.8
Schneider Electric / Modicon MC80 Controller
|
BMKC80
|
1.8 | |
|
Schneider Electric Modicon Momentum Unity M1E Processor Version SV2.6
Schneider Electric / Modicon Momentum Unity M1E Processor
|
171CBU*
|
SV2.6 | |
|
Schneider Electric Modicon X80 Module BMXNOM0200 Version 1.60
Schneider Electric / Modicon X80 Module / BMXNOM0200
|
1.60 | ||
|
Schneider Electric Modicon X80 Module BMENOS0300 Version 1.04
Schneider Electric / Modicon X80 Module / BMENOS0300
|
1.04 | ||
|
Schneider Electric Eurotherm nanodac Version 10.02
Schneider Electric / Eurotherm / nanodac
|
10.02 | ||
|
Schneider Electric PacDrive Eco Logic Controllers Version 1.66.5.1
Schneider Electric / PacDrive / PacDrive Eco Logic Controllers
|
1.66.5.1 | ||
|
Schneider Electric PacDrive Pro Logic Controllers Version 1.66.5.1
Schneider Electric / PacDrive / PacDrive Pro Logic Controllers
|
1.66.5.1 | ||
|
Schneider Electric PacDrive Pro2 Logic Controllers Version 1.66.5.1
Schneider Electric / PacDrive / PacDrive Pro2 Logic Controllers
|
1.66.5.1 | ||
|
Schneider Electric PowerLogic ION7400 Version 3.1
Schneider Electric / PowerLogic / ION7400
|
3.1 | ||
|
Schneider Electric PowerLogic PM8000 Version 3.1
Schneider Electric / PowerLogic / PM8000
|
3.1 | ||
|
Schneider Electric PowerLogic ION9000 Version 3.1
Schneider Electric / PowerLogic / ION9000
|
3.1 | ||
| Unresolved product id: 156 | — | ||
| Unresolved product id: 157 | — | ||
| Unresolved product id: 158 | — | ||
| Unresolved product id: 159 | — | ||
| Unresolved product id: 160 | — | ||
| Unresolved product id: 162 | — | ||
| Unresolved product id: 165 | — | ||
| Unresolved product id: 166 | — | ||
|
Schneider Electric SCD6000 Industrial RTU Version SY-1101207_N
Schneider Electric / SCD6000 Industrial RTU
|
SY-1101207_N | ||
|
Schneider Electric SAGE RTU CPU C3414 Version C3414-500-S02K5_P5
Schneider Electric / SAGE RTU CPU C3414
|
C3414-500-S02K5_P5 | ||
|
Schneider Electric Eurotherm Versadac Version 2.43
Schneider Electric / Eurotherm / Versadac Scalable Data Recorder
|
2.43 | ||
|
Schneider Electric BMECRA31210 Version SV02.80
Schneider Electric / BMECRA31210
|
SV02.80 | ||
|
Schneider Electric BMXCRA31200 Version SV02.80
Schneider Electric / BMXCRA31200
|
SV02.80 | ||
|
Schneider Electric BMXCRA31210 Version SV02.80
Schneider Electric / BMXCRA31210
|
SV02.80 | ||
|
Schneider Electric 140CRA31200 (Quantum RIO Drop) Version 02.80
Schneider Electric / 140CRA31200 (Quantum RIO Drop)
|
02.80 | ||
|
Schneider Electric 140CRA31908 (M580 Quantum S908 RIO Drop Adapter) Version 02.80
Schneider Electric / 140CRA31908 (M580 Quantum S908 RIO Drop Adapter)
|
02.80 | ||
|
Schneider Electric BMENOP0300 Version SV2.6
Schneider Electric / BMENOP0300
|
SV2.6 | ||
| Unresolved product id: 202 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Easergy C5x Versions prior to 1.0.5
Schneider Electric / Easergy
|
C52C53
|
<1.0.5 |
Vendor Fix
|
|
Schneider Electric Easergy MiCOM P30 v660 to v674
Schneider Electric / Easergy MiCOM P30
|
P138P139P436P437P438P439P532P631P632P633P634C434
|
>=660|<=674 |
Vendor Fix
|
|
Schneider Electric Easergy MiCOM P30 v660 to v674
Schneider Electric / Easergy MiCOM P30
|
P638
|
>=660|<=674 |
Vendor Fix
|
|
Schneider Electric Easergy MiCOM P30 v660 to v674
Schneider Electric / Easergy MiCOM P30
|
P132P433P435
|
>=660|<=674 |
Mitigation
|
|
Schneider Electric Easergy P5 Versions prior to 01.401.101
Schneider Electric / Easergy P5
|
<01.401.101 |
Vendor Fix
|
|
|
Schneider Electric Eurotherm EPC2000 Versions prior to v4.03
Schneider Electric / Eurotherm / EPC2000
|
<4.03 |
Vendor Fix
fix
|
|
|
Schneider Electric Eurotherm EPC3000 Versions prior to v5.20
Schneider Electric / Eurotherm / EPC3000
|
<5.20 |
Vendor Fix
fix
|
|
| Unresolved product id: 17 | — |
Vendor Fix
|
|
| Unresolved product id: 20 | — |
Vendor Fix
|
|
|
Schneider Electric Eurotherm E+PLC100 All Versions
Schneider Electric / Eurotherm / E+PLC100
|
vers:all/* |
No Fix Planned
Mitigation
|
|
|
Schneider Electric Eurotherm E+PLC400 Versions prior to v1.4.0.0
Schneider Electric / Eurotherm / E+PLC400
|
<1.4.0.0 |
Vendor Fix
|
|
|
Schneider Electric Eurotherm Eycon 10/20 Visual Supervisor Versions prior to 7.3
Schneider Electric / Eurotherm / Eycon 10/20 Visual Supervisor
|
<7.3 |
Vendor Fix
fix
|
|
|
Schneider Electric Eurotherm T2550 PAC Versions prior to 8.2
Schneider Electric / Eurotherm / T2550 PAC
|
<8.2 |
Vendor Fix
fix
|
|
|
Schneider Electric Eurotherm T2750 PAC Versions prior to 6.3
Schneider Electric / Eurotherm / T2750 PAC
|
<6.3 |
Vendor Fix
fix
|
|
| Unresolved product id: 37 | — |
Vendor Fix
|
|
| Unresolved product id: 40 | — |
Vendor Fix
|
|
| Unresolved product id: 43 | — |
Vendor Fix
|
|
| Unresolved product id: 50 | — |
Vendor Fix
|
|
| Unresolved product id: 57 | — |
Vendor Fix
fix
|
|
|
Schneider Electric MiCOM C264 Versions greater than or equal to B5.x and prior to B5.118
Schneider Electric / MiCOM C264
|
>=B5.x|<B5.118 |
Vendor Fix
|
|
|
Schneider Electric MiCOM C264 Versions greater than or equal to D1.x and prior to D1.92
Schneider Electric / MiCOM C264
|
>=D1.x|<D1.92 |
Vendor Fix
|
|
|
Schneider Electric MiCOM C264 Versions greater than or equal to D4.x and prior to D4.38
Schneider Electric / MiCOM C264
|
>=D4.x|<D4.38 |
Vendor Fix
|
|
|
Schneider Electric MiCOM C264 Versions greater than or equal to D5.x and prior to D5.25I
Schneider Electric / MiCOM C264
|
>=D5.x|<D5.25I |
Vendor Fix
|
|
|
Schneider Electric MiCOM C264 Versions greater than or equal to D6.x and prior to D6.18
Schneider Electric / MiCOM C264
|
>=D6.x|<D6.18 |
Vendor Fix
|
|
|
Schneider Electric Modicon M241 Logic Controllers Versions prior to 5.1.9.34
Schneider Electric / Modicon M241 Logic Controllers
|
<5.1.9.34 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M251 Logic Controllers Versions prior to 5.1.9.34
Schneider Electric / Modicon M251 Logic Controllers
|
<5.1.9.34 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M262 Logic Controllers Versions prior to 5.1.6.1
Schneider Electric / Modicon M262 Logic Controllers
|
<5.1.6.1 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M258 Logic Controllers Versions prior to 5.0.4.18
Schneider Electric / Modicon M258 Logic Controllers
|
<5.0.4.18 |
Vendor Fix
|
|
|
Schneider Electric Modicon LMC058 Logic Controllers Versions prior to 5.0.4.18
Schneider Electric / Modicon LMC058 Logic Controllers
|
<5.0.4.18 |
Vendor Fix
|
|
|
Schneider Electric Modicon M340 Module BMXNOC0401 Versions prior to v2.11
Schneider Electric / Modicon M340 Module / BMXNOC0401
|
<2.11 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M340 Ethernet Communication Modules BMXNOE0100 (H) Versions prior to SV3.50
Schneider Electric / Modicon M340 Ethernet Communication Modules / BMXNOE0100 (H)
|
<SV3.50 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M340 Ethernet Communication Modules BMXNOE0110 (H) Versions prior to SV6.70
Schneider Electric / Modicon M340 Ethernet Communication Modules / BMXNOE0110 (H)
|
<SV6.70 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M340 Module BMXNOR0200 (H) RTU Versions prior to v1.7 IR24
Schneider Electric / Modicon M340 Module / BMXNOR0200 (H) RTU
|
<1.7 IR24 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M340 CPU Versions prior to 3.50
Schneider Electric / Modicon M340 CPU
|
BMXP34*
|
<3.50 |
Vendor Fix
fix
|
|
Schneider Electric Modicon M580 CPU Versions prior to SV4.10
Schneider Electric / Modicon M580 CPU
|
BMEP*BMEH*
|
<SV4.10 |
Vendor Fix
fix
|
|
Schneider Electric Modicon M580 CPU Safety Versions prior to SV4.21
Schneider Electric / Modicon M580 CPU Safety
|
BMEP58*SBMEH58*S
|
<SV4.21 |
Vendor Fix
fix
|
|
Schneider Electric Modicon M580 Ethernet Communication Modules BMENOC0301 Versions prior to SV2.21
Schneider Electric / Modicon M580 Ethernet Communication Modules / BMENOC0301
|
<SV2.21 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M580 Ethernet Communication Modules BMENOC0311 Versions prior to SV2.21
Schneider Electric / Modicon M580 Ethernet Communication Modules / BMENOC0311
|
<SV2.21 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon M580 NOC Control BMENOC0321 Versions prior to SV1.09
Schneider Electric / Modicon M580 NOC Control / BMENOC0321
|
<SV1.09 |
Vendor Fix
fix
|
|
|
Schneider Electric HART X80 Module BMEAHI0812 Versions prior to SV1.5
Schneider Electric / HART IO X80 Module / BMEAHI0812
|
<SV1.5 |
Vendor Fix
fix
|
|
|
Schneider Electric HART X80 Module BMEAHO0412 Versions prior to SV1.5
Schneider Electric / HART IO X80 Module / BMEAHO0412
|
<SV1.5 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon MC80 Controller Versions prior to v1.8
Schneider Electric / Modicon MC80 Controller
|
BMKC8*
|
<1.8 |
Vendor Fix
fix
|
|
Schneider Electric Modicon Momentum ENT All Versions
Schneider Electric / Modicon Momentum ENT
|
170ENT11*
|
vers:all/* |
Mitigation
|
|
Schneider Electric Modicon Momentum Unity M1E Processor Versions prior to SV2.6
Schneider Electric / Modicon Momentum Unity M1E Processor
|
171CBU*
|
<SV2.6 |
Vendor Fix
fix
|
|
Schneider Electric Modicon Quantum CPU and Communication Modules All Versions
Schneider Electric / Modicon Quantum CPU and Communication Modules
|
vers:all/* |
No Fix Planned
Mitigation
|
|
|
Schneider Electric Modicon Premium CPU and Communication Modules All Versions
Schneider Electric / Modicon Premium CPU and Communication Modules
|
vers:all/* |
No Fix Planned
Mitigation
|
|
|
Schneider Electric Modicon X80 Module BMXNOM0200 Versions prior to v1.60
Schneider Electric / Modicon X80 Module / BMXNOM0200
|
<1.60 |
Vendor Fix
fix
|
|
|
Schneider Electric Modicon X80 Module BMENOS0300 Versions prior to v1.04
Schneider Electric / Modicon X80 Module / BMENOS0300
|
<1.04 |
Vendor Fix
fix
|
|
|
Schneider Electric Eurotherm nanodac Versions prior to 10.02
Schneider Electric / Eurotherm / nanodac
|
<10.02 |
Vendor Fix
fix
|
|
|
Schneider Electric PacDrive Eco Logic Controllers Versions prior to 1.66.5.1
Schneider Electric / PacDrive / PacDrive Eco Logic Controllers
|
<1.66.5.1 |
Vendor Fix
|
|
|
Schneider Electric PacDrive Pro Logic Controllers Versions prior to 1.66.5.1
Schneider Electric / PacDrive / PacDrive Pro Logic Controllers
|
<1.66.5.1 |
Vendor Fix
|
|
|
Schneider Electric PacDrive Pro2 Logic Controllers Versions prior to 1.66.5.1
Schneider Electric / PacDrive / PacDrive Pro2 Logic Controllers
|
<1.66.5.1 |
Vendor Fix
|
|
|
Schneider Electric PacDrive M Logic Controller All Versions
Schneider Electric / PacDrive / PacDrive M Logic Controller
|
vers:all/* |
No Fix Planned
Mitigation
|
|
|
Schneider Electric PowerLogic ION7400 Versions prior to v3.1
Schneider Electric / PowerLogic / ION7400
|
<3.1 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric PowerLogic PM8000 Versions prior to v3.1
Schneider Electric / PowerLogic / PM8000
|
<3.1 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric PowerLogic ION9000 Versions prior to v3.1
Schneider Electric / PowerLogic / ION9000
|
<3.1 |
Vendor Fix
fix
Mitigation
|
|
| Unresolved product id: 151 | — |
Vendor Fix
fix
|
|
| Unresolved product id: 152 | — |
Vendor Fix
fix
|
|
| Unresolved product id: 153 | — |
Vendor Fix
fix
|
|
| Unresolved product id: 154 | — |
Vendor Fix
fix
|
|
| Unresolved product id: 155 | — |
Vendor Fix
fix
|
|
| Unresolved product id: 161 | — |
Vendor Fix
fix
|
|
| Unresolved product id: 163 | — |
Vendor Fix
fix
|
|
| Unresolved product id: 164 | — |
Vendor Fix
fix
|
|
|
Schneider Electric Profibus Remote Master TCSEGPA23F14F All Versions
Schneider Electric / Profibus Remote Master / TCSEGPA23F14F
|
vers:all/* |
Mitigation
fix
|
|
|
Schneider Electric Profibus Remote Master BMECXM0100 All Versions
Schneider Electric / Profibus Remote Master / BMECXM0100
|
vers:all/* |
Mitigation
fix
|
|
|
Schneider Electric SCD6000 Industrial RTU Versions prior to SY-1101207_N
Schneider Electric / SCD6000 Industrial RTU
|
<SY-1101207_N |
Vendor Fix
|
|
|
Schneider Electric SAGE RTU CPU C3414 Versions prior to C3414-500-S02K5_P5
Schneider Electric / SAGE RTU CPU C3414
|
<C3414-500-S02K5_P5 |
Vendor Fix
fix
|
|
|
Schneider Electric Eurotherm Versadac Scalable Data Recorder Versions prior to 2.43
Schneider Electric / Eurotherm / Versadac Scalable Data Recorder
|
<2.43 |
Vendor Fix
fix
|
|
|
Schneider Electric BMECRA31210 Versions prior to SV02.80
Schneider Electric / BMECRA31210
|
<SV02.80 |
Vendor Fix
fix
|
|
|
Schneider Electric BMXCRA31200 Versions prior to SV02.80
Schneider Electric / BMXCRA31200
|
<SV02.80 |
Vendor Fix
fix
|
|
|
Schneider Electric BMXCRA31210 Versions prior to SV02.80
Schneider Electric / BMXCRA31210
|
<SV02.80 |
Vendor Fix
fix
|
|
|
Schneider Electric 140CRA31200 (Quantum RIO Drop) Versions prior to V02.80
Schneider Electric / 140CRA31200 (Quantum RIO Drop)
|
<02.80 |
Vendor Fix
fix
|
|
|
Schneider Electric 140CRA31908 (M580 Quantum S908 RIO Drop Adapter) Versions prior to V02.80
Schneider Electric / 140CRA31908 (M580 Quantum S908 RIO Drop Adapter)
|
<02.80 |
Vendor Fix
fix
|
|
|
Schneider Electric BMENOP0300 Versions prior to SV2.6
Schneider Electric / BMENOP0300
|
<02.80 |
Vendor Fix
fix
|
|
|
Schneider Electric BMXNGD0100 All Versions
Schneider Electric / BMXNGD0100
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Easergy MiCOM P30 v660 to v674
Schneider Electric / Easergy MiCOM P30
|
Px36Px38
|
>=660|<=674 |
Mitigation
|
|
Schneider Electric Easergy MiCOM P40 All Versions
Schneider Electric / Easergy MiCOM P40
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric EPack All Versions
Schneider Electric / EPack
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric HMISTO5 Series All Versions
Schneider Electric / HMISTO5 Series
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Modicon LMC078 All Versions
Schneider Electric / Modicon LMC078
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Pro-face GP4100 Series All Versions
Schneider Electric / Pro-face / GP4100 Series
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Pro-face GP4000E Series All Versions
Schneider Electric / Pro-face / GP4000E Series
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Pro-face GP4000M Series All Versions
Schneider Electric / Pro-face / GP4000M Series
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Eurotherm 6100A All Versions
Schneider Electric / Eurotherm / 6100A
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Eurotherm 6180A All Versions
Schneider Electric / Eurotherm / 6180A
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Eurotherm 6100XIO All Versions
Schneider Electric / Eurotherm / 6100XIO
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Eurotherm 6180XIO All Versions
Schneider Electric / Eurotherm / 6180XIO
|
vers:all/* |
Mitigation
|
|
|
Schneider Electric Eurotherm AeroDAQ All Versions
Schneider Electric / Eurotherm / AeroDAQ
|
vers:all/* |
Mitigation
|
An integer overflow vulnerability in the calloc() function of the C runtime library of affected versions of BlackBerry® QNX Software Development Platform (SDP) version(s) 6.5.0SP1 and earlier, QNX OS for Medical 1.1 and earlier, and QNX OS for Safety 1.0.1 and earlier that could allow an attacker to potentially perform a denial of service or execute arbitrary code.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: 66 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: 64 | — |
Vendor Fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\n\nFor more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\n\nFor further information related to cybersecurity in Schneider Electric\u0027s products, visit the company\u0027s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "Schneider\u0027s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and\r\nsustainability for all. We call this Life Is On.\n\nOur mission is to be the trusted partner in Sustainability and Efficiency.\n\nWe are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart\r\nindustries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep\r\ndomain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,\r\nsoftware and services, delivering digital twins to enable profitable growth for our customers.\n\nWe are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries\r\nto ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our\r\nmeaningful purpose of a sustainable future for all. \n\n www.se.com",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple memory allocation vulnerabilities dubbed \u0027BadAlloc\u0027, disclosed by \nMicrosoft on April 29, 2021. The impact of a successful exploitation of the vulnerabilities may result in denial of \nservice, or remote code execution, depending on the context. \n\nSeptember 2025 Update: Corrected and updated affected versions for EPC2000, EPC3000, Eurotherm E+PLC400, Eurotherm Eycon 10/20 Visual Supervisor, Eurotherm T2550 PAC, and Eurotherm T2750 PAC.",
"title": "Overview"
},
{
"category": "details",
"text": "The complete list of affected real-time operating systems can be found here: https://us-cert.cisa.gov/ics/advisories/icsa-21-119-04",
"title": "Vulnerability Details"
},
{
"category": "other",
"text": "Schneider Electric has determined that the following offers are impacted and has provided remediations, for \nthose listed in the Available Remediations section, and recommended mitigations, for those in the Affected \nProducts section. \nPlease subscribe to the Schneider Electric security notification service to be informed of critical updates to this \nnotification, including information on affected products and remediation plans:\nhttps://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp",
"title": "Affected Products, Remediations \u0026 Mitigations"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "BadAlloc Vulnerabilities - SEVD-2021-313-05 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2021-313-05.json"
},
{
"category": "self",
"summary": "BadAlloc Vulnerabilities - SEVD-2021-313-05 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_BadAlloc_Vulnerabilities_Security_Notification.pdf"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "BadAlloc Vulnerabilities",
"tracking": {
"current_release_date": "2025-09-09T04:00:00.000Z",
"generator": {
"date": "2025-09-02T06:36:57.616Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2021-313-05",
"initial_release_date": "2021-11-09T05:00:00.000Z",
"revision_history": [
{
"date": "2021-11-09T05:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2021-11-17T06:30:00.000Z",
"number": "1.1.0",
"summary": "Fixed version number of PacDrive Eco/Pro/Pro2 Logic Controllers \ncorrected to v1.66.5.1."
},
{
"date": "2021-12-14T06:30:00.000Z",
"number": "2.0.0",
"summary": "Remediations added for SCD6000 Industrial RTU, PowerLogic \nION7400, PowerLogic ION8000, PowerLogic ION9000. Upon further \ninvestigation Tricon Communication Modules have been removed from \nlist of affected products and are not impacted by the Badalloc \nVulnerabilities."
},
{
"date": "2021-12-15T06:30:00.000Z",
"number": "3.0.0",
"summary": "Remediations added for PowerLogic ION9000."
},
{
"date": "2022-01-11T06:30:00.000Z",
"number": "4.0.0",
"summary": "Remediations added for Easergy P5, EPC3000, Harmony/ Magelis \nHMIGTU Series, HMIGTUX Series, HMIGK Series, nanodac, Pro-face \nSP-5B00, SP-5B10,SP-5B90,ST6000 Series (GP-ProEX model), \nET6000 Series in the Available Remediations section (page 1, 2, 4, and \n6). Updated versions affected to all versions for Pro-face GP4000 \nSeries, LT4000M Series, GP4000H Series in the Affected Versions\nsection. "
},
{
"date": "2022-01-13T06:30:00.000Z",
"number": "4.1.0",
"summary": "Moved back to affected products section: Harmony/ Magelis HMIGTU \nSeries, HMIGTUX Series, HMIGK Series. "
},
{
"date": "2022-02-08T06:30:00.000Z",
"number": "5.0.0",
"summary": "Available remediations for Easy Harmony ET6 (HMIET Series), Easy \nHarmony GXU (HMIGXU Series), Harmony/ Magelis (HMIGTU Series, \nHMIGTUX Series, HMIGK Series), Modicon M262 Logic Controllers, \nand Modicon M241/M251 Logic Controllers. Added Easergy MiCOM \nP30 and Easergy MiCOM P40 to the list of affected products."
},
{
"date": "2022-04-12T06:30:00.000Z",
"number": "6.0.0",
"summary": "Added remediations for Eurotherm E+PLC400, Eurotherm T2750 PAC \nand Modicon M340 CPU. Additionally, Eurotherm T2550 PAC and \nEurotherm Eycon 10/20 Visual Supervisor have been added as affected \nproducts to this security notification in the remediation section."
},
{
"date": "2022-05-10T00:00:00.000Z",
"number": "7.0.0",
"summary": "Added a remediation for HMISCU, added the following affected models \nto the Easergy MiCOM P30 range: C434, P132, P139, P433, P435, \nP437, P532, P631, P632, P633, P634, Px36/8."
},
{
"date": "2022-06-13T18:30:00.000Z",
"number": "8.0.0",
"summary": "Added a remediation for EPC2000, v4.03 includes a fix. "
},
{
"date": "2022-06-14T18:30:00.000Z",
"number": "9.0.0",
"summary": "Remediation added for Versadac. The previously added remediation for \nEPC2000 has been removed as v4.03 is not yet available, this \ndocument will be updated when it is released."
},
{
"date": "2022-08-09T06:30:00.000Z",
"number": "10.0.0",
"summary": "Remediations available for Modicon M580 CPU (BMEP* and BMEH*)\nand Pro-face GP4000 Series, GP4000H Series GP-Pro EX. "
},
{
"date": "2022-09-13T06:30:00.000Z",
"number": "11.0.0",
"summary": "Final Remediations available for Modicon M340 Modules \nBMXNOC0401 and BMXNOR0200H RTU, and Modicon MC80 \nController (BMKC8*). There is a mitigation available for Profibus \nRemote Master (TCSEGPA23F14F) and CANopen X80 \nCommunication Module (BMECXM0100)."
},
{
"date": "2022-10-11T00:00:00.000Z",
"number": "12.0.0",
"summary": "Easergy MiCOM P30 range P632 and P633 were added as affected \nmodels along with a remediation. Final mitigations were added for \nModicon Momentum ENT. Adding a clarification to the list of affected \nproducts by splitting Modicon M580 and Modicon M580 Safety CPU \nranges; the latest fix Modicon M580 v4.02 does not apply to the Safety \nrange of M580."
},
{
"date": "2022-11-08T00:00:00.000Z",
"number": "13.0.0",
"summary": "A remediation is now available for EPC2000."
},
{
"date": "2022-12-13T00:00:00.000Z",
"number": "14.0.0",
"summary": "The Modicon M580 SV4.02 firmware has been retracted for quality \nissues and is no longer available for download. Additional mitigations \nhave been introduced for Modicon M580 CPU and M580 CPU Safety, \nand we urge customers to deploy these mitigations to further reduce \nthe risk of potential exploitation of identified vulnerabilities."
},
{
"date": "2023-01-10T00:00:00.000Z",
"number": "15.0.0",
"summary": "There are remediations available for Easergy MiCOM P30 range and\nPro-face LT4000M Series. "
},
{
"date": "2023-02-14T00:00:00.000Z",
"number": "16.0.0",
"summary": "There is a remediation for Modicon M340 Ethernet Communication \nModules BMXNOE0100 (H) and BMXNOE0110 (H) products."
},
{
"date": "2023-03-14T06:30:00.000Z",
"number": "17.0.0",
"summary": "Remediations for the following products are now available: Easergy \nMiCOM P30 range models P139, P437, P439, P532, P631, P632, \nP633, P634, C434 (page 2), Modicon M580 CPU part numbers BMEP* \nand BMEH (page 7), and Modicon Momentum Unity M1E Processor \npart numbers 171CBU* (page 8). Mitigations for Easergy MiCOM P30 \nrange, models P138, P436, P438, P132, P433, P435 have been added."
},
{
"date": "2023-04-11T06:30:00.000Z",
"number": "18.0.0",
"summary": "Remediations are now available for Modicon M580 Ethernet \nCommunication Modules BMENOC*."
},
{
"date": "2023-05-09T06:30:00.000Z",
"number": "19.0.0",
"summary": "A remediation is now available for Modicon X80 Module (part number \nBMXNOM0200)."
},
{
"date": "2023-07-11T00:00:00.000Z",
"number": "20.0.0",
"summary": "A remediation is now available for HART IO X80 Module (part number \nBMEAHI0812, BMEAHO0412)."
},
{
"date": "2024-03-12T00:00:00.000Z",
"number": "21.0.0",
"summary": "Easergy MiCOM P30 range models 139 and 436 were added to \nAffected Products."
},
{
"date": "2024-08-13T00:00:00.000Z",
"number": "22.0.0",
"summary": "A remediation is available on Modicon M580 CPU Safety."
},
{
"date": "2024-09-10T00:00:00.000Z",
"number": "23.0.0",
"summary": "A remediation is available on HMISTU (page 4)."
},
{
"date": "2024-11-12T00:00:00.000Z",
"number": "24.0.0",
"summary": "Changes have been made to the Easergy MiCOM P30 remediation \ndescription and we have added model P638 to the list of Easergy \nMiCOM P30s with a remediation."
},
{
"date": "2025-01-14T00:00:00.000Z",
"number": "25.0.0",
"summary": "A remediation is available for Modicon X80 module, part number \nBMENOS0300 (Page 10)."
},
{
"date": "2025-04-08T04:00:00.000Z",
"number": "26.0.0",
"summary": "A remediation is available for BMECRA31210, BMXCRA31200, \nBMXCRA31210 (Page 13) and mitigations for this product have been \nupdated. "
},
{
"date": "2025-08-12T04:00:00.000Z",
"number": "27.0.0",
"summary": "Remediations are available for 140CRA31200 (Quantum RIO Drop), \n140CRA31908 (M580 Quantum S908 RIO Drop Adapter) (Page 13), \nand BMENOP0300 (Page 14)."
},
{
"date": "2025-09-09T04:00:00.000Z",
"number": "28.0.0",
"summary": "Corrected and updated affected versions for EPC2000, EPC3000, Eurotherm E+PLC400, Eurotherm Eycon 10/20 Visual Supervisor, Eurotherm T2550 PAC, and Eurotherm T2750 PAC."
}
],
"status": "final",
"version": "28.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.0.5",
"product": {
"name": "Schneider Electric Easergy C5x Versions prior to 1.0.5",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"C52",
"C53"
]
}
}
},
{
"category": "product_version",
"name": "1.0.5",
"product": {
"name": "Schneider Electric Easergy C5x Version 1.0.5",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Easergy"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=660|\u003c=674",
"product": {
"name": "Schneider Electric Easergy MiCOM P30 v660 to v674",
"product_id": "3",
"product_identification_helper": {
"model_numbers": [
"P138",
"P139",
"P436",
"P437",
"P438",
"P439",
"P532",
"P631",
"P632",
"P633",
"P634",
"C434"
]
}
}
},
{
"category": "product_version_range",
"name": "\u003e=675",
"product": {
"name": "Schneider Electric Easergy MiCOM P30 Version 675 and later",
"product_id": "4"
}
},
{
"category": "product_version_range",
"name": "\u003e=660|\u003c=674",
"product": {
"name": "Schneider Electric Easergy MiCOM P30 v660 to v674",
"product_id": "5",
"product_identification_helper": {
"model_numbers": [
"P638"
]
}
}
},
{
"category": "product_version",
"name": "676.701",
"product": {
"name": "Schneider Electric Easergy MiCOM P30 Version 676.701",
"product_id": "6",
"product_identification_helper": {
"model_numbers": [
"P638"
]
}
}
},
{
"category": "product_version_range",
"name": "\u003e=660|\u003c=674",
"product": {
"name": "Schneider Electric Easergy MiCOM P30 v660 to v674",
"product_id": "7",
"product_identification_helper": {
"model_numbers": [
"P132",
"P433",
"P435"
]
}
}
},
{
"category": "product_version_range",
"name": "\u003e=660|\u003c=674",
"product": {
"name": "Schneider Electric Easergy MiCOM P30 v660 to v674",
"product_id": "188",
"product_identification_helper": {
"model_numbers": [
"Px36",
"Px38"
]
}
}
}
],
"category": "product_name",
"name": "Easergy MiCOM P30"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c01.401.101",
"product": {
"name": "Schneider Electric Easergy P5 Versions prior to 01.401.101",
"product_id": "8"
}
},
{
"category": "product_version",
"name": "01.401.101",
"product": {
"name": "Schneider Electric Easergy P5 Version 01.401.101",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "Easergy P5"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.03",
"product": {
"name": "Schneider Electric Eurotherm EPC2000 Versions prior to v4.03",
"product_id": "10"
}
},
{
"category": "product_version",
"name": "4.03",
"product": {
"name": "Schneider Electric Eurotherm EPC2000 Version 4.03",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "EPC2000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.20",
"product": {
"name": "Schneider Electric Eurotherm EPC3000 Versions prior to v5.20",
"product_id": "12"
}
},
{
"category": "product_version",
"name": "5.20",
"product": {
"name": "Schneider Electric Eurotherm EPC3000 Version 5.20",
"product_id": "13"
}
}
],
"category": "product_name",
"name": "EPC3000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Eurotherm E+PLC100 All Versions",
"product_id": "22"
}
}
],
"category": "product_name",
"name": "E+PLC100"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.4.0.0",
"product": {
"name": "Schneider Electric Eurotherm E+PLC400 Versions prior to v1.4.0.0",
"product_id": "23"
}
},
{
"category": "product_version",
"name": "1.4.0.0",
"product": {
"name": "Schneider Electric Eurotherm E+PLC400 Version 1.4.0.0",
"product_id": "24"
}
}
],
"category": "product_name",
"name": "E+PLC400"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c7.3",
"product": {
"name": "Schneider Electric Eurotherm Eycon 10/20 Visual Supervisor Versions prior to 7.3",
"product_id": "25"
}
},
{
"category": "product_version",
"name": "7.3",
"product": {
"name": "Schneider Electric Eurotherm Eycon 10/20 Visual Supervisor Version 7.3",
"product_id": "26"
}
}
],
"category": "product_name",
"name": "Eycon 10/20 Visual Supervisor"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c8.2",
"product": {
"name": "Schneider Electric Eurotherm T2550 PAC Versions prior to 8.2",
"product_id": "27"
}
},
{
"category": "product_version",
"name": "8.2",
"product": {
"name": "Schneider Electric Eurotherm T2550 PAC Version 8.2",
"product_id": "28"
}
}
],
"category": "product_name",
"name": "T2550 PAC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c6.3",
"product": {
"name": "Schneider Electric Eurotherm T2750 PAC Versions prior to 6.3",
"product_id": "29"
}
},
{
"category": "product_version",
"name": "6.3",
"product": {
"name": "Schneider Electric Eurotherm T2750 PAC Version 6.3",
"product_id": "30"
}
}
],
"category": "product_name",
"name": "T2750 PAC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c10.02",
"product": {
"name": "Schneider Electric Eurotherm nanodac Versions prior to 10.02",
"product_id": "122"
}
},
{
"category": "product_version",
"name": "10.02",
"product": {
"name": "Schneider Electric Eurotherm nanodac Version 10.02",
"product_id": "123"
}
}
],
"category": "product_name",
"name": "nanodac"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c2.43",
"product": {
"name": "Schneider Electric Eurotherm Versadac Scalable Data Recorder Versions prior to 2.43",
"product_id": "173"
}
},
{
"category": "product_version",
"name": "2.43",
"product": {
"name": "Schneider Electric Eurotherm Versadac Version 2.43",
"product_id": "174"
}
}
],
"category": "product_name",
"name": "Versadac Scalable Data Recorder"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Eurotherm 6100A All Versions",
"product_id": "196"
}
}
],
"category": "product_name",
"name": "6100A"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Eurotherm 6180A All Versions",
"product_id": "197"
}
}
],
"category": "product_name",
"name": "6180A"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Eurotherm 6100XIO All Versions",
"product_id": "198"
}
}
],
"category": "product_name",
"name": "6100XIO"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Eurotherm 6180XIO All Versions",
"product_id": "199"
}
}
],
"category": "product_name",
"name": "6180XIO"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Eurotherm AeroDAQ All Versions",
"product_id": "200"
}
}
],
"category": "product_name",
"name": "AeroDAQ"
}
],
"category": "product_family",
"name": "Eurotherm"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.2.1",
"product": {
"name": "Schneider Electric Vijeo Designer Basic Versions prior to 1.2.1",
"product_id": "14"
}
},
{
"category": "product_version",
"name": "1.2.1",
"product": {
"name": "Schneider Electric Vijeo Designer Basic Version 1.2.1",
"product_id": "15"
}
}
],
"category": "product_name",
"name": "Vijeo Designer Basic"
},
{
"branches": [
{
"category": "product_name",
"name": "ET6 (HMIET Series)",
"product": {
"name": "Schneider Electric Easy Harmony ET6 (HMIET Series)",
"product_id": "16"
}
},
{
"category": "product_name",
"name": "GXU (HMIGXU Series)",
"product": {
"name": "Schneider Electric Easy Harmony GXU (HMIGXU Series)",
"product_id": "19"
}
}
],
"category": "product_family",
"name": "Easy Harmony"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c6.2 SP11 Multi HotFix 4",
"product": {
"name": "Schneider Electric Vijeo Designer Versions prior to 6.2 SP11 Multi HotFix 4",
"product_id": "31"
}
},
{
"category": "product_version",
"name": "6.2 SP11 Multi HotFix 4",
"product": {
"name": "Schneider Electric Vijeo Designer Version 6.2 SP11 Multi HotFix 4",
"product_id": "32"
}
},
{
"category": "product_version_range",
"name": "\u003e=6.2 SP11 Multi HotFix 4",
"product": {
"name": "Schneider Electric Vijeo Designer Version 6.2 SP11 Multi HotFix 4 (or above)",
"product_id": "33"
}
},
{
"category": "product_version_range",
"name": "\u003c6.2 SP12",
"product": {
"name": "Schneider Electric Vijeo Designer Versions prior to 6.2 SP12",
"product_id": "47"
}
},
{
"category": "product_version",
"name": "6.2 SP12",
"product": {
"name": "Schneider Electric Vijeo Designer Version 6.2 SP12",
"product_id": "48"
}
},
{
"category": "product_version_range",
"name": "\u003e=6.2 SP12",
"product": {
"name": "Schneider Electric Vijeo Designer Versions 6.2 SP12 (or above)",
"product_id": "49"
}
},
{
"category": "product_version_range",
"name": "\u003c6.3 SP1",
"product": {
"name": "Schneider Electric Vijeo Designer Versions prior to v6.3 SP1",
"product_id": "54"
}
},
{
"category": "product_version",
"name": "6.3 SP1",
"product": {
"name": "Schneider Electric Vijeo Designer Version 6.3 SP1",
"product_id": "55"
}
},
{
"category": "product_version_range",
"name": "\u003e=6.3 SP1",
"product": {
"name": "Schneider Electric Vijeo Designer Version 6.3 SP1 (or above)",
"product_id": "56"
}
}
],
"category": "product_name",
"name": "Vijeo Designer"
},
{
"branches": [
{
"category": "product_name",
"name": "HMIGTU Series",
"product": {
"name": "Schneider Electric Harmony/ Magelis HMIGTU Series",
"product_id": "34"
}
},
{
"category": "product_name",
"name": "HMIGTUX Series",
"product": {
"name": "Schneider Electric Harmony/ Magelis HMIGTUX Series",
"product_id": "35"
}
},
{
"category": "product_name",
"name": "HMIGK Series",
"product": {
"name": "Schneider Electric Harmony/ Magelis HMIGK Series",
"product_id": "36"
}
}
],
"category": "product_family",
"name": "Harmony/ Magelis"
},
{
"category": "product_name",
"name": "HMISCU",
"product": {
"name": "Schneider Electric HMISCU",
"product_id": "46"
}
},
{
"category": "product_name",
"name": "HMISTU Series",
"product": {
"name": "Schneider Electric HMISTU Series",
"product_id": "53"
}
},
{
"category": "product_family",
"name": "TAC I/A Series",
"product": {
"name": "Schneider Electric TAC I/A Series",
"product_id": "60"
}
},
{
"category": "product_name",
"name": "JACE-8000",
"product": {
"name": "Schneider Electric JACE-8000",
"product_id": "61"
}
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.10u1",
"product": {
"name": "Schneider Electric Niagara Framework Versions prior to v4.10u1",
"product_id": "62"
}
},
{
"category": "product_version",
"name": "4.10u1",
"product": {
"name": "Schneider Electric Niagara Framework Version 4.10u1",
"product_id": "65"
}
}
],
"category": "product_name",
"name": "Niagara Framework"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=B5.x|\u003cB5.118",
"product": {
"name": "Schneider Electric MiCOM C264 Versions greater than or equal to B5.x and prior to B5.118",
"product_id": "67"
}
},
{
"category": "product_version",
"name": "B5.118",
"product": {
"name": "Schneider Electric MiCOM C264 Version B5.118",
"product_id": "68"
}
},
{
"category": "product_version_range",
"name": "\u003e=D1.x|\u003cD1.92",
"product": {
"name": "Schneider Electric MiCOM C264 Versions greater than or equal to D1.x and prior to D1.92",
"product_id": "69"
}
},
{
"category": "product_version",
"name": "D1.92",
"product": {
"name": "Schneider Electric MiCOM C264 Version D1.92",
"product_id": "70"
}
},
{
"category": "product_version_range",
"name": "\u003e=D4.x|\u003cD4.38",
"product": {
"name": "Schneider Electric MiCOM C264 Versions greater than or equal to D4.x and prior to D4.38",
"product_id": "71"
}
},
{
"category": "product_version",
"name": "D4.38",
"product": {
"name": "Schneider Electric MiCOM C264 Version D4.38",
"product_id": "72"
}
},
{
"category": "product_version_range",
"name": "\u003e=D5.x|\u003cD5.25I",
"product": {
"name": "Schneider Electric MiCOM C264 Versions greater than or equal to D5.x and prior to D5.25I",
"product_id": "73"
}
},
{
"category": "product_version",
"name": "D5.25I",
"product": {
"name": "Schneider Electric MiCOM C264 Version D5.25I",
"product_id": "74"
}
},
{
"category": "product_version_range",
"name": "\u003e=D6.x|\u003cD6.18",
"product": {
"name": "Schneider Electric MiCOM C264 Versions greater than or equal to D6.x and prior to D6.18",
"product_id": "75"
}
},
{
"category": "product_version",
"name": "D6.18",
"product": {
"name": "Schneider Electric MiCOM C264 Version D6.18",
"product_id": "76"
}
}
],
"category": "product_name",
"name": "MiCOM C264"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.1.9.34",
"product": {
"name": "Schneider Electric Modicon M241 Logic Controllers Versions prior to 5.1.9.34",
"product_id": "77"
}
},
{
"category": "product_version_range",
"name": "\u003e=5.1.9.34",
"product": {
"name": "Schneider Electric Modicon M241 Logic Controllers Version 5.1.9.34 or greater",
"product_id": "78"
}
}
],
"category": "product_name",
"name": "Modicon M241 Logic Controllers"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.1.9.34",
"product": {
"name": "Schneider Electric Modicon M251 Logic Controllers Versions prior to 5.1.9.34",
"product_id": "79"
}
},
{
"category": "product_version_range",
"name": "\u003e=5.1.9.34",
"product": {
"name": "Schneider Electric Modicon M251 Logic Controllers Version 5.1.9.34 or greater",
"product_id": "80"
}
}
],
"category": "product_name",
"name": "Modicon M251 Logic Controllers"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.1.6.1",
"product": {
"name": "Schneider Electric Modicon M262 Logic Controllers Versions prior to 5.1.6.1",
"product_id": "81"
}
},
{
"category": "product_version_range",
"name": "\u003e=5.1.6.1",
"product": {
"name": "Schneider Electric Modicon M262 Logic Controllers Version 5.1.6.1 or greater",
"product_id": "82"
}
}
],
"category": "product_name",
"name": "Modicon M262 Logic Controllers"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.0.4.18",
"product": {
"name": "Schneider Electric Modicon M258 Logic Controllers Versions prior to 5.0.4.18",
"product_id": "83"
}
},
{
"category": "product_version",
"name": "5.0.4.18",
"product": {
"name": "Schneider Electric Modicon M258 Logic Controllers Version 5.0.4.18",
"product_id": "84"
}
}
],
"category": "product_name",
"name": "Modicon M258 Logic Controllers"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.0.4.18",
"product": {
"name": "Schneider Electric Modicon LMC058 Logic Controllers Versions prior to 5.0.4.18",
"product_id": "85"
}
},
{
"category": "product_version",
"name": "5.0.4.18",
"product": {
"name": "Schneider Electric Modicon LMC058 Logic Controllers Version 5.0.4.18",
"product_id": "86"
}
}
],
"category": "product_name",
"name": "Modicon LMC058 Logic Controllers"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c2.11",
"product": {
"name": "Schneider Electric Modicon M340 Module BMXNOC0401 Versions prior to v2.11",
"product_id": "87"
}
},
{
"category": "product_version",
"name": "2.11",
"product": {
"name": "Schneider Electric Modicon M340 Module BMXNOC0401 Version v2.11",
"product_id": "88"
}
}
],
"category": "product_name",
"name": "BMXNOC0401"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.7 IR24",
"product": {
"name": "Schneider Electric Modicon M340 Module BMXNOR0200 (H) RTU Versions prior to v1.7 IR24",
"product_id": "93"
}
},
{
"category": "product_version",
"name": "1.7 IR24",
"product": {
"name": "Schneider Electric Modicon M340 Module BMXNOR0200 (H) RTU Version 1.7 IR24",
"product_id": "94"
}
}
],
"category": "product_name",
"name": "BMXNOR0200 (H) RTU"
}
],
"category": "product_family",
"name": "Modicon M340 Module"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV3.50",
"product": {
"name": "Schneider Electric Modicon M340 Ethernet Communication Modules BMXNOE0100 (H) Versions prior to SV3.50",
"product_id": "89"
}
},
{
"category": "product_version",
"name": "SV3.50",
"product": {
"name": "Schneider Electric Modicon M340 Ethernet Communication Modules BMXNOE0100 (H) Version SV3.50",
"product_id": "90"
}
}
],
"category": "product_name",
"name": "BMXNOE0100 (H)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV6.70",
"product": {
"name": "Schneider Electric Modicon M340 Ethernet Communication Modules BMXNOE0110 (H) Versions prior to SV6.70",
"product_id": "91"
}
},
{
"category": "product_version",
"name": "SV6.70",
"product": {
"name": "Schneider Electric Modicon M340 Ethernet Communication Modules BMXNOE0110 (H) Version SV6.70",
"product_id": "92"
}
}
],
"category": "product_name",
"name": "BMXNOE0110 (H)"
}
],
"category": "product_family",
"name": "Modicon M340 Ethernet Communication Modules"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.50",
"product": {
"name": "Schneider Electric Modicon M340 CPU Versions prior to 3.50",
"product_id": "95",
"product_identification_helper": {
"model_numbers": [
"BMXP34*"
]
}
}
},
{
"category": "product_version",
"name": "3.50",
"product": {
"name": "Schneider Electric Modicon M340 CPU Version 3.50",
"product_id": "96",
"product_identification_helper": {
"model_numbers": [
"BMXP34*"
]
}
}
}
],
"category": "product_name",
"name": "Modicon M340 CPU"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV4.10",
"product": {
"name": "Schneider Electric Modicon M580 CPU Versions prior to SV4.10",
"product_id": "97",
"product_identification_helper": {
"model_numbers": [
"BMEP*",
"BMEH*"
]
}
}
},
{
"category": "product_version",
"name": "SV4.10",
"product": {
"name": "Schneider Electric Modicon M580 CPU Version SV4.10",
"product_id": "98",
"product_identification_helper": {
"model_numbers": [
"BMEP*",
"BMEH*"
]
}
}
}
],
"category": "product_name",
"name": "Modicon M580 CPU"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV4.21",
"product": {
"name": "Schneider Electric Modicon M580 CPU Safety Versions prior to SV4.21",
"product_id": "99",
"product_identification_helper": {
"model_numbers": [
"BMEP58*S",
"BMEH58*S"
]
}
}
},
{
"category": "product_version",
"name": "SV4.21",
"product": {
"name": "Schneider Electric Modicon M580 CPU Safety Version SV4.21",
"product_id": "100",
"product_identification_helper": {
"model_numbers": [
"BMEP58*S",
"BMEH58*S"
]
}
}
}
],
"category": "product_name",
"name": "Modicon M580 CPU Safety"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=16.0 HF001",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 Control Expert Versions greater than or equal to 16.0 HF001",
"product_id": "201"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Control Expert"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV2.21",
"product": {
"name": "Schneider Electric Modicon M580 Ethernet Communication Modules BMENOC0301 Versions prior to SV2.21",
"product_id": "101"
}
},
{
"category": "product_version",
"name": "SV2.21",
"product": {
"name": "Schneider Electric Modicon M580 Ethernet Communication Modules BMENOC0301 Version SV2.21",
"product_id": "102"
}
}
],
"category": "product_name",
"name": "BMENOC0301"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV2.21",
"product": {
"name": "Schneider Electric Modicon M580 Ethernet Communication Modules BMENOC0311 Versions prior to SV2.21",
"product_id": "103"
}
},
{
"category": "product_version",
"name": "SV2.21",
"product": {
"name": "Schneider Electric Modicon M580 Ethernet Communication Modules BMENOC0311 Version SV2.21",
"product_id": "104"
}
}
],
"category": "product_name",
"name": "BMENOC0311"
}
],
"category": "product_family",
"name": "Modicon M580 Ethernet Communication Modules"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV1.09",
"product": {
"name": "Schneider Electric Modicon M580 NOC Control BMENOC0321 Versions prior to SV1.09",
"product_id": "105"
}
},
{
"category": "product_version",
"name": "SV1.09",
"product": {
"name": "Schneider Electric Modicon M580 NOC Control BMENOC0321 Version SV1.09",
"product_id": "106"
}
}
],
"category": "product_name",
"name": "BMENOC0321"
}
],
"category": "product_name",
"name": "Modicon M580 NOC Control"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV1.5",
"product": {
"name": "Schneider Electric HART X80 Module BMEAHI0812 Versions prior to SV1.5",
"product_id": "107"
}
},
{
"category": "product_version",
"name": "SV1.5",
"product": {
"name": "Schneider Electric HART X80 Module BMEAHI0812 Version SV1.5",
"product_id": "108"
}
}
],
"category": "product_name",
"name": "BMEAHI0812"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV1.5",
"product": {
"name": "Schneider Electric HART X80 Module BMEAHO0412 Versions prior to SV1.5",
"product_id": "109"
}
},
{
"category": "product_version",
"name": "SV1.5",
"product": {
"name": "Schneider Electric HART X80 Module BMEAHO0412 Version SV1.5",
"product_id": "110"
}
}
],
"category": "product_name",
"name": "BMEAHO0412"
}
],
"category": "product_family",
"name": "HART IO X80 Module"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.8",
"product": {
"name": "Schneider Electric Modicon MC80 Controller Versions prior to v1.8",
"product_id": "111",
"product_identification_helper": {
"model_numbers": [
"BMKC8*"
]
}
}
},
{
"category": "product_version",
"name": "1.8",
"product": {
"name": "Schneider Electric Modicon MC80 Controller Version v1.8",
"product_id": "112",
"product_identification_helper": {
"model_numbers": [
"BMKC80"
]
}
}
}
],
"category": "product_name",
"name": "Modicon MC80 Controller"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Modicon Momentum ENT All Versions",
"product_id": "113",
"product_identification_helper": {
"model_numbers": [
"170ENT11*"
]
}
}
}
],
"category": "product_name",
"name": "Modicon Momentum ENT"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV2.6",
"product": {
"name": "Schneider Electric Modicon Momentum Unity M1E Processor Versions prior to SV2.6",
"product_id": "114",
"product_identification_helper": {
"model_numbers": [
"171CBU*"
]
}
}
},
{
"category": "product_version",
"name": "SV2.6",
"product": {
"name": "Schneider Electric Modicon Momentum Unity M1E Processor Version SV2.6",
"product_id": "115",
"product_identification_helper": {
"model_numbers": [
"171CBU*"
]
}
}
}
],
"category": "product_name",
"name": "Modicon Momentum Unity M1E Processor"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Modicon Quantum CPU and Communication Modules All Versions",
"product_id": "116"
}
}
],
"category": "product_name",
"name": "Modicon Quantum CPU and Communication Modules"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Modicon Premium CPU and Communication Modules All Versions",
"product_id": "117"
}
}
],
"category": "product_name",
"name": "Modicon Premium CPU and Communication Modules"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.60",
"product": {
"name": "Schneider Electric Modicon X80 Module BMXNOM0200 Versions prior to v1.60",
"product_id": "118"
}
},
{
"category": "product_version",
"name": "1.60",
"product": {
"name": "Schneider Electric Modicon X80 Module BMXNOM0200 Version 1.60",
"product_id": "119"
}
}
],
"category": "product_name",
"name": "BMXNOM0200"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.04",
"product": {
"name": "Schneider Electric Modicon X80 Module BMENOS0300 Versions prior to v1.04",
"product_id": "120"
}
},
{
"category": "product_version",
"name": "1.04",
"product": {
"name": "Schneider Electric Modicon X80 Module BMENOS0300 Version 1.04",
"product_id": "121"
}
}
],
"category": "product_name",
"name": "BMENOS0300"
}
],
"category": "product_family",
"name": "Modicon X80 Module"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.66.5.1",
"product": {
"name": "Schneider Electric PacDrive Eco Logic Controllers Versions prior to 1.66.5.1",
"product_id": "124"
}
},
{
"category": "product_version",
"name": "1.66.5.1",
"product": {
"name": "Schneider Electric PacDrive Eco Logic Controllers Version 1.66.5.1",
"product_id": "125"
}
}
],
"category": "product_name",
"name": "PacDrive Eco Logic Controllers"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.66.5.1",
"product": {
"name": "Schneider Electric PacDrive Pro Logic Controllers Versions prior to 1.66.5.1",
"product_id": "126"
}
},
{
"category": "product_version",
"name": "1.66.5.1",
"product": {
"name": "Schneider Electric PacDrive Pro Logic Controllers Version 1.66.5.1",
"product_id": "127"
}
}
],
"category": "product_name",
"name": "PacDrive Pro Logic Controllers"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.66.5.1",
"product": {
"name": "Schneider Electric PacDrive Pro2 Logic Controllers Versions prior to 1.66.5.1",
"product_id": "128"
}
},
{
"category": "product_version",
"name": "1.66.5.1",
"product": {
"name": "Schneider Electric PacDrive Pro2 Logic Controllers Version 1.66.5.1",
"product_id": "129"
}
}
],
"category": "product_name",
"name": "PacDrive Pro2 Logic Controllers"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric PacDrive M Logic Controller All Versions",
"product_id": "130"
}
}
],
"category": "product_name",
"name": "PacDrive M Logic Controller"
}
],
"category": "product_family",
"name": "PacDrive"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.1",
"product": {
"name": "Schneider Electric PowerLogic ION7400 Versions prior to v3.1",
"product_id": "131"
}
},
{
"category": "product_version",
"name": "3.1",
"product": {
"name": "Schneider Electric PowerLogic ION7400 Version 3.1",
"product_id": "132"
}
}
],
"category": "product_name",
"name": "ION7400"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.1",
"product": {
"name": "Schneider Electric PowerLogic PM8000 Versions prior to v3.1",
"product_id": "133"
}
},
{
"category": "product_version",
"name": "3.1",
"product": {
"name": "Schneider Electric PowerLogic PM8000 Version 3.1",
"product_id": "134"
}
}
],
"category": "product_name",
"name": "PM8000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.1",
"product": {
"name": "Schneider Electric PowerLogic ION9000 Versions prior to v3.1",
"product_id": "135"
}
},
{
"category": "product_version_range",
"name": "3.1",
"product": {
"name": "Schneider Electric PowerLogic ION9000 Version 3.1",
"product_id": "136"
}
}
],
"category": "product_name",
"name": "ION9000"
}
],
"category": "product_family",
"name": "PowerLogic"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.09.350",
"product": {
"name": "Schneider Electric Pro-face GP-Pro EX Versions prior to 4.09.350",
"product_id": "137"
}
},
{
"category": "product_version_range",
"name": "\u003e=4.09.350",
"product": {
"name": "Schneider Electric Pro-face GP-Pro EX Version 4.09.350 or later",
"product_id": "138"
}
},
{
"category": "product_version_range",
"name": "\u003c4.09.450",
"product": {
"name": "Schneider Electric Pro-face GP-Pro EX Versions prior to 4.09.450",
"product_id": "147"
}
},
{
"category": "product_version_range",
"name": "\u003e=4.09.450",
"product": {
"name": "Schneider Electric Pro-face GP-Pro EX Version 4.09.450 or later",
"product_id": "148"
}
},
{
"category": "product_version_range",
"name": "\u003c4.09.400",
"product": {
"name": "Schneider Electric Pro-face GP-Pro EX Versions prior to 4.09.400",
"product_id": "149"
}
},
{
"category": "product_version_range",
"name": "\u003e=4.09.400",
"product": {
"name": "Schneider Electric Pro-face GP-Pro EX Version 4.09.400 or later",
"product_id": "150"
}
}
],
"category": "product_name",
"name": "GP-Pro EX"
},
{
"category": "product_name",
"name": "SP-5B00",
"product": {
"name": "Schneider Electric Pro-face SP-5B00",
"product_id": "139"
}
},
{
"category": "product_name",
"name": "SP-5B10",
"product": {
"name": "Schneider Electric Pro-face SP-5B10",
"product_id": "140"
}
},
{
"category": "product_name",
"name": "SP-5B90",
"product": {
"name": "Schneider Electric Pro-face SP-5B90",
"product_id": "141"
}
},
{
"category": "product_name",
"name": "ST6000 Series",
"product": {
"name": "Schneider Electric Pro-face ST6000 Series (GP-ProEX model)",
"product_id": "142"
}
},
{
"category": "product_name",
"name": "ET6000 Series",
"product": {
"name": "Schneider Electric Pro-face ET6000 Series",
"product_id": "143"
}
},
{
"category": "product_name",
"name": "LT4000M Series",
"product": {
"name": "Schneider Electric Pro-face LT4000M Series",
"product_id": "144"
}
},
{
"category": "product_name",
"name": "GP4000 Series",
"product": {
"name": "Schneider Electric Pro-face GP4000 Series",
"product_id": "145"
}
},
{
"category": "product_name",
"name": "GP4000H Series",
"product": {
"name": "Schneider Electric Pro-face GP4000H Series",
"product_id": "146"
}
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Pro-face GP4100 Series All Versions",
"product_id": "193"
}
}
],
"category": "product_name",
"name": "GP4100 Series"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Pro-face GP4000E Series All Versions",
"product_id": "194"
}
}
],
"category": "product_name",
"name": "GP4000E Series"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Pro-face GP4000M Series All Versions",
"product_id": "195"
}
}
],
"category": "product_name",
"name": "GP4000M Series"
}
],
"category": "product_family",
"name": "Pro-face"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Profibus Remote Master TCSEGPA23F14F All Versions",
"product_id": "167"
}
}
],
"category": "product_name",
"name": "TCSEGPA23F14F"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Profibus Remote Master BMECXM0100 All Versions",
"product_id": "168"
}
}
],
"category": "product_name",
"name": "BMECXM0100"
}
],
"category": "product_family",
"name": "Profibus Remote Master"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSY-1101207_N",
"product": {
"name": "Schneider Electric SCD6000 Industrial RTU Versions prior to SY-1101207_N",
"product_id": "169"
}
},
{
"category": "product_version",
"name": "SY-1101207_N",
"product": {
"name": "Schneider Electric SCD6000 Industrial RTU Version SY-1101207_N",
"product_id": "170"
}
}
],
"category": "product_name",
"name": "SCD6000 Industrial RTU"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cC3414-500-S02K5_P5",
"product": {
"name": "Schneider Electric SAGE RTU CPU C3414 Versions prior to C3414-500-S02K5_P5",
"product_id": "171"
}
},
{
"category": "product_version",
"name": "C3414-500-S02K5_P5",
"product": {
"name": "Schneider Electric SAGE RTU CPU C3414 Version C3414-500-S02K5_P5",
"product_id": "172"
}
}
],
"category": "product_name",
"name": "SAGE RTU CPU C3414"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV02.80",
"product": {
"name": "Schneider Electric BMECRA31210 Versions prior to SV02.80",
"product_id": "175"
}
},
{
"category": "product_version",
"name": "SV02.80",
"product": {
"name": "Schneider Electric BMECRA31210 Version SV02.80",
"product_id": "176"
}
}
],
"category": "product_name",
"name": "BMECRA31210"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV02.80",
"product": {
"name": "Schneider Electric BMXCRA31200 Versions prior to SV02.80",
"product_id": "177"
}
},
{
"category": "product_version",
"name": "SV02.80",
"product": {
"name": "Schneider Electric BMXCRA31200 Version SV02.80",
"product_id": "178"
}
}
],
"category": "product_name",
"name": "BMXCRA31200"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV02.80",
"product": {
"name": "Schneider Electric BMXCRA31210 Versions prior to SV02.80",
"product_id": "179"
}
},
{
"category": "product_version",
"name": "SV02.80",
"product": {
"name": "Schneider Electric BMXCRA31210 Version SV02.80",
"product_id": "180"
}
}
],
"category": "product_name",
"name": "BMXCRA31210"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c02.80",
"product": {
"name": "Schneider Electric 140CRA31200 (Quantum RIO Drop) Versions prior to V02.80",
"product_id": "181"
}
},
{
"category": "product_version_range",
"name": "02.80",
"product": {
"name": "Schneider Electric 140CRA31200 (Quantum RIO Drop) Version 02.80",
"product_id": "182"
}
}
],
"category": "product_name",
"name": "140CRA31200 (Quantum RIO Drop)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c02.80",
"product": {
"name": "Schneider Electric 140CRA31908 (M580 Quantum S908 RIO Drop Adapter) Versions prior to V02.80",
"product_id": "183"
}
},
{
"category": "product_version_range",
"name": "02.80",
"product": {
"name": "Schneider Electric 140CRA31908 (M580 Quantum S908 RIO Drop Adapter) Version 02.80",
"product_id": "184"
}
}
],
"category": "product_name",
"name": "140CRA31908 (M580 Quantum S908 RIO Drop Adapter)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c02.80",
"product": {
"name": "Schneider Electric BMENOP0300 Versions prior to SV2.6",
"product_id": "185"
}
},
{
"category": "product_version_range",
"name": "SV2.6",
"product": {
"name": "Schneider Electric BMENOP0300 Version SV2.6",
"product_id": "186"
}
}
],
"category": "product_name",
"name": "BMENOP0300"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric BMXNGD0100 All Versions",
"product_id": "187"
}
}
],
"category": "product_name",
"name": "BMXNGD0100"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Easergy MiCOM P40 All Versions",
"product_id": "189"
}
}
],
"category": "product_name",
"name": "Easergy MiCOM P40"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric EPack All Versions",
"product_id": "190"
}
}
],
"category": "product_name",
"name": "EPack"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric HMISTO5 Series All Versions",
"product_id": "191"
}
}
],
"category": "product_name",
"name": "HMISTO5 Series"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Modicon LMC078 All Versions",
"product_id": "192"
}
}
],
"category": "product_name",
"name": "Modicon LMC078"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
],
"relationships": [
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Basic Versions prior to 1.2.1 installed on Schneider Electric Easy Harmony ET6 (HMIET Series)",
"product_id": "17"
},
"product_reference": "14",
"relates_to_product_reference": "16"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Basic Version 1.2.1 installed on Schneider Electric Easy Harmony ET6 (HMIET Series)",
"product_id": "18"
},
"product_reference": "15",
"relates_to_product_reference": "16"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Basic Versions prior to 1.2.1 installed on Schneider Electric Easy Harmony GXU (HMIGXU Series)",
"product_id": "20"
},
"product_reference": "14",
"relates_to_product_reference": "19"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Basic Version 1.2.1 installed on Schneider Electric Easy Harmony GXU (HMIGXU Series)",
"product_id": "21"
},
"product_reference": "15",
"relates_to_product_reference": "19"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Versions prior to 6.2 SP11 Multi HotFix 4 installed on Schneider Electric Harmony/ Magelis HMIGTU Series",
"product_id": "37"
},
"product_reference": "31",
"relates_to_product_reference": "34"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Version 6.2 SP11 Multi HotFix 4 installed on Schneider Electric Harmony/ Magelis HMIGTU Series",
"product_id": "38"
},
"product_reference": "32",
"relates_to_product_reference": "34"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Version 6.2 SP11 Multi HotFix 4 (or above) installed on Schneider Electric Harmony/ Magelis HMIGTU Series",
"product_id": "39"
},
"product_reference": "33",
"relates_to_product_reference": "34"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Versions prior to 6.2 SP11 Multi HotFix 4 installed on Schneider Electric Harmony/ Magelis HMIGTUX Series",
"product_id": "40"
},
"product_reference": "31",
"relates_to_product_reference": "35"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Version 6.2 SP11 Multi HotFix 4 installed on Schneider Electric Harmony/ Magelis HMIGTUX Series",
"product_id": "41"
},
"product_reference": "32",
"relates_to_product_reference": "35"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Version 6.2 SP11 Multi HotFix 4 (or above) installed on Schneider Electric Harmony/ Magelis HMIGTUX Series",
"product_id": "42"
},
"product_reference": "33",
"relates_to_product_reference": "35"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Versions prior to 6.2 SP11 Multi HotFix 4 installed on Schneider Electric Harmony/ Magelis HMIGK Series",
"product_id": "43"
},
"product_reference": "31",
"relates_to_product_reference": "36"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Version 6.2 SP11 Multi HotFix 4 installed on Schneider Electric Harmony/ Magelis HMIGK Series",
"product_id": "44"
},
"product_reference": "32",
"relates_to_product_reference": "36"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Version 6.2 SP11 Multi HotFix 4 (or above) installed on Schneider Electric Harmony/ Magelis HMIGK Series",
"product_id": "45"
},
"product_reference": "33",
"relates_to_product_reference": "36"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Versions prior to 6.2 SP12 installed on Schneider Electric HMISCU",
"product_id": "50"
},
"product_reference": "47",
"relates_to_product_reference": "46"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Version 6.2 SP12 installed on Schneider Electric HMISCU",
"product_id": "51"
},
"product_reference": "48",
"relates_to_product_reference": "46"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Versions 6.2 SP12 (or above) installed on Schneider Electric HMISCU",
"product_id": "52"
},
"product_reference": "49",
"relates_to_product_reference": "46"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Versions prior to v6.3 SP1 installed on Schneider Electric HMISTU Series",
"product_id": "57"
},
"product_reference": "54",
"relates_to_product_reference": "53"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Version 6.3 SP1 installed on Schneider Electric HMISTU Series",
"product_id": "58"
},
"product_reference": "55",
"relates_to_product_reference": "53"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Vijeo Designer Version 6.3 SP1 (or above) installed on Schneider Electric HMISTU Series",
"product_id": "59"
},
"product_reference": "56",
"relates_to_product_reference": "53"
},
{
"category": "optional_component_of",
"full_product_name": {
"name": "Schneider Electric JACE-8000 optional component of Schneider Electric TAC I/A Series",
"product_id": "63"
},
"product_reference": "61",
"relates_to_product_reference": "60"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Niagara Framework Versions prior to v4.10u1 installed on JACE-8000 optional component of Schneider Electric TAC I/A Series",
"product_id": "64"
},
"product_reference": "62",
"relates_to_product_reference": "63"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Niagara Framework Version 4.10u1 installed on JACE-8000 optional component of Schneider Electric TAC I/A Series",
"product_id": "66"
},
"product_reference": "65",
"relates_to_product_reference": "63"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Versions prior to 4.09.350 installed on Schneider Electric Pro-face SP-5B00",
"product_id": "151"
},
"product_reference": "137",
"relates_to_product_reference": "139"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Versions prior to 4.09.350 installed on Schneider Electric Pro-face SP-5B10",
"product_id": "152"
},
"product_reference": "137",
"relates_to_product_reference": "140"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Versions prior to 4.09.350 installed on Schneider Electric Pro-face SP-5B90",
"product_id": "153"
},
"product_reference": "137",
"relates_to_product_reference": "141"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Versions prior to 4.09.350 installed on Schneider Electric Pro-face ST6000 Series (GP-ProEX model)",
"product_id": "154"
},
"product_reference": "137",
"relates_to_product_reference": "142"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Versions prior to 4.09.350 installed on Schneider Electric Pro-face ET6000 Series",
"product_id": "155"
},
"product_reference": "137",
"relates_to_product_reference": "143"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Version 4.09.350 or later installed on Schneider Electric Pro-face SP-5B00",
"product_id": "156"
},
"product_reference": "138",
"relates_to_product_reference": "139"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Version 4.09.350 or later installed on Schneider Electric Pro-face SP-5B10",
"product_id": "157"
},
"product_reference": "138",
"relates_to_product_reference": "140"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Version 4.09.350 or later installed on Schneider Electric Pro-face SP-5B90",
"product_id": "158"
},
"product_reference": "138",
"relates_to_product_reference": "141"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Version 4.09.350 or later installed on Schneider Electric Pro-face ST6000 Series (GP-ProEX model)",
"product_id": "159"
},
"product_reference": "138",
"relates_to_product_reference": "142"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Version 4.09.350 or later installed on Schneider Electric Pro-face ET6000 Series",
"product_id": "160"
},
"product_reference": "138",
"relates_to_product_reference": "143"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Versions prior to 4.09.450 installed on Schneider Electric Pro-face LT4000M Series",
"product_id": "161"
},
"product_reference": "147",
"relates_to_product_reference": "144"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Version 4.09.450 or later installed on Schneider Electric Pro-face LT4000M Series",
"product_id": "162"
},
"product_reference": "148",
"relates_to_product_reference": "144"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Versions prior to 4.09.400 installed on Schneider Electric Pro-face GP4000 Series",
"product_id": "163"
},
"product_reference": "149",
"relates_to_product_reference": "145"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Versions prior to 4.09.400 installed on Schneider Electric Pro-face GP4000H Series",
"product_id": "164"
},
"product_reference": "149",
"relates_to_product_reference": "146"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Version 4.09.400 or later installed on Schneider Electric Pro-face GP4000 Series",
"product_id": "165"
},
"product_reference": "150",
"relates_to_product_reference": "145"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Pro-face GP-Pro EX Version 4.09.400 or later installed on Schneider Electric Pro-face GP4000H Series",
"product_id": "166"
},
"product_reference": "150",
"relates_to_product_reference": "146"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Modicon M580 CPU Safety Version SV4.21 installed on Schneider Electric EcoStruxure\u2122 Control Expert Versions greater than or equal to 16.0 HF001",
"product_id": "202"
},
"product_reference": "100",
"relates_to_product_reference": "201"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"urls": [
"https://us-cert.cisa.gov/ics/advisories/icsa-21-119-04"
]
}
],
"cve": "CVE-2020-35198",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "description",
"text": "An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2",
"4",
"6",
"11",
"13",
"18",
"21",
"24",
"26",
"28",
"30",
"38",
"39",
"41",
"42",
"44",
"45",
"51",
"52",
"58",
"59",
"68",
"70",
"72",
"74",
"76",
"78",
"80",
"82",
"84",
"86",
"88",
"90",
"92",
"94",
"96",
"98",
"102",
"104",
"106",
"108",
"110",
"112",
"115",
"119",
"121",
"123",
"125",
"127",
"129",
"132",
"134",
"136",
"156",
"157",
"158",
"159",
"160",
"162",
"165",
"166",
"170",
"172",
"174",
"176",
"178",
"180",
"182",
"184",
"186",
"202"
],
"known_affected": [
"1",
"3",
"5",
"7",
"10",
"12",
"17",
"20",
"22",
"23",
"25",
"27",
"29",
"37",
"40",
"43",
"50",
"57",
"67",
"69",
"71",
"73",
"75",
"77",
"79",
"81",
"83",
"85",
"87",
"89",
"91",
"93",
"95",
"97",
"99",
"101",
"103",
"105",
"107",
"109",
"111",
"113",
"114",
"116",
"117",
"118",
"120",
"122",
"124",
"126",
"128",
"130",
"131",
"133",
"135",
"151",
"152",
"153",
"154",
"155",
"161",
"163",
"164",
"167",
"168",
"169",
"171",
"173",
"175",
"177",
"179",
"181",
"183",
"185",
"187",
"188",
"190",
"191",
"192",
"193",
"194",
"195",
"196",
"197",
"198",
"199",
"200"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 1.0.5 of Easergy C5 includes a fix for these vulnerabilities and \nis available through Schneider Electric regional DPACs.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Easergy MiCOM P638 Version 676.701 of the P30 firmware includes a fix for these vulnerabilities and is available on request from Schneider Electric\u2019s Customer Care",
"product_ids": [
"5"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "All other Easergy MiCOM P30 Models: Version 675 and later of the P30 firmware includes a fix for these vulnerabilities and is available on request from Schneider Electric\u2019s Customer Care Center.",
"product_ids": [
"3"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit: \u2022 Use relays only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Disable unused network protocol interfaces. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Activate and apply user management and password features. ",
"product_ids": [
"7"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 4.03 of the EPC2000 includes a fix for these vulnerabilities and is available for download here:https://www.eurotherm.com/?wpdmdl=137741",
"product_ids": [
"10"
],
"restart_required": {
"category": "none"
},
"url": "https://www.eurotherm.com/?wpdmdl=137741"
},
{
"category": "vendor_fix",
"details": "Version 5.20 of the EPC3000 includes a fix for these vulnerabilities and is available for download here:https://www.eurotherm.com/?wpdmdl=89545 Device will reboot automatically after upgrade.",
"product_ids": [
"12"
],
"restart_required": {
"category": "system"
},
"url": "https://www.eurotherm.com/?wpdmdl=89545"
},
{
"category": "vendor_fix",
"details": "Version 1.2.1 of Vijeo Designer Basic includes a fix for these vulnerabilities. Please contact your Schneider Electric\u2019s Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic V1.2.1.",
"product_ids": [
"17",
"20"
],
"restart_required": {
"category": "none"
}
},
{
"category": "no_fix_planned",
"details": "The E+PLC100 product has reached its end of life and is no longer supported.",
"product_ids": [
"22"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Setup network segmentation and implement a firewall to block all unauthorized access to the device.\u2022 Configure the Access Control List following the recommendations of the device user manual.\u2022 Setup a VPN between the E+PLC100 device and any remote visualization workstations running the E+PLC tools.\u2022 Activate and apply user management and password features. Limit the access to both development and control system by physical means, operating system features, etc.",
"product_ids": [
"22"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 1.4.0.0 of the E+PLC400 firmware is available and includes a fix for these vulnerabilities. Please contact the Eurotherm Support team to obtain the firmware update. Please be sure to include the following when contacting the support team:\u2022 End Username, Company, and Email Address\u2022 Serial numbers of the devices to be upgraded\u2022 Current E+PLC400 firmware version",
"product_ids": [
"23"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 1.4.0.0 of the E+PLC400 firmware is available and includes a fix for these vulnerabilities. Please contact the Eurotherm Support team to obtain the firmware update. Please be sure to include the following when contacting the support team:\u2022 End Username, Company, and Email Address\u2022 Serial numbers of the devices to be upgraded\u2022 Current E+PLC400 firmware versionVersion 7.3 of the Eycon firmware is available and includes a fix for these vulnerabilities. Access to the patch can be obtained through the following link: https://partners.eurotherm.com/member-login",
"product_ids": [
"25"
],
"restart_required": {
"category": "none"
},
"url": "https://partners.eurotherm.com/member-login"
},
{
"category": "vendor_fix",
"details": "Version 8.2 of the T2550 firmware is available and includes a fix for these vulnerabilities. Access to the patch can be obtained through the following link: https://partners.eurotherm.com/member-login ",
"product_ids": [
"27"
],
"restart_required": {
"category": "none"
},
"url": "https://partners.eurotherm.com/member-login"
},
{
"category": "vendor_fix",
"details": "Version 6.3 of the T2750 firmware is available and includes a fix for these vulnerabilities. Access to the patch can be obtained through the following link:https://partners.eurotherm.com/member-login",
"product_ids": [
"29"
],
"restart_required": {
"category": "none"
},
"url": "https://partners.eurotherm.com/member-login"
},
{
"category": "vendor_fix",
"details": "Version 6.2 SP11 Multi HotFix 4 of Vijeo Designer includes a fix for these vulnerabilities and can be updated through the Schneider Electric Software Update (SESU) application. On the engineering workstation, update to V6.2 SP11 Multi HotFix 4 (or above) of Vijeo Designer.To complete the update, connect to Harmony HMI and download the project file using Vijeo Designer V6.2 SP11 Multi HotFix 4.",
"product_ids": [
"37",
"40",
"43"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 6.2 SP12 of Vijeo Designer includes a fix for these vulnerabilities and can be updated through the Schneider Electric Software Update (SESU) application. On the engineering workstation, update to V6.2 SP12 (or above) of Vijeo Designer. To complete the update, connect to Harmony HMI and download the project file using Vijeo Designer V6.2 SP12.",
"product_ids": [
"50"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 6.3 SP1 of Vijeo Designer includes a fix for these vulnerabilities and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware On the engineering workstation, update to V6.3 SP1 (or above) of Vijeo Designer. To complete the update, connect to Harmony HMI and download the project file using Vijeo Designer V6.3 SP1.",
"product_ids": [
"57"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Versions B5.118, D1.92, D4.38, D5.25I and D6.18 of MiCOM C264 include a fix for these vulnerabilities and are available through Schneider Electric regional DPACs.",
"product_ids": [
"67",
"69",
"71",
"73",
"75"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 5.1.9.34 of Modicon M241/M251 Logic Controllers includes a fix for these vulnerabilities.On the engineering workstation, update to latest version of EcoStruxure Machine Expert: https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-somachine/?parent-subcategory-id=5140\u0026filter=business-1-industrial-automation-and-control To complete the update on Modicon M241/M251 Logic Controllers, update to firmware version V5.1.9.34 or higher available within EcoStruxure Machine Expert. A reboot is needed.",
"product_ids": [
"77",
"79"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-somachine/?parent-subcategory-id=5140\u0026filter=business-1-industrial-automation-and-control"
},
{
"category": "vendor_fix",
"details": "Version 5.1.6.1 of Modicon M262 Logic Controllers includes a fix for these vulnerabilities.On the engineering workstation, update to latest version of EcoStruxure Machine Expert: https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-somachine/?parent-subcategory-id=5140\u0026filter=business-1-industrial-automation-and-controlTo complete the update on Modicon M262 Logic Controllers, update to firmware version V5.1.6.1 or higher available within EcoStruxure Machine Expert. A reboot is needed.",
"product_ids": [
"81"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-somachine/?parent-subcategory-id=5140\u0026filter=business-1-industrial-automation-and-control"
},
{
"category": "vendor_fix",
"details": "Firmware Version 5.0.4.18 of Modicon M258/LMC058 logic controllers includes a fix for these vulnerabilities and can be updated through Schneider Electric Software Update (SESU) application.",
"product_ids": [
"83",
"85"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 2.11 of BMXNOC0401 includes a fix for thesevulnerabilities and is available for download here:https://www.se.com/ww/en/product/BMXNOC0401/",
"product_ids": [
"87"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/BMXNOC0401/"
},
{
"category": "vendor_fix",
"details": "Version SV3.50 of BMXNOE0100 (H) includes a fix for thesevulnerabilities and is available for download here:https://www.se.com/ww/en/download/document/BMXNOE0100_SV_03.50/",
"product_ids": [
"89"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMXNOE0100_SV_03.50/"
},
{
"category": "vendor_fix",
"details": "Version SV6.70 of BMXNOE0110 (H) includes a fix for thesevulnerabilities and is available for download here:https://www.se.com/ww/en/download/document/BMXNOE0110_SV_06.70/",
"product_ids": [
"91"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMXNOE0110_SV_06.70/"
},
{
"category": "vendor_fix",
"details": "Version 1.7 IR24 of BMXNOR0200H includes a fix for thesevulnerabilities and is available for download here:https://www.se.com/ww/en/product/BMXNOR0200H/",
"product_ids": [
"93"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/BMXNOR0200H/"
},
{
"category": "vendor_fix",
"details": "Version 3.50 of Modicon M340 includes a fix for these vulnerabilities and is available for download here:https://www.se.com/ww/en/download/document/BMXP34xxxxx_SV_03.50/ ",
"product_ids": [
"95"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMXP34xxxxx_SV_03.50/"
},
{
"category": "vendor_fix",
"details": "Version SV4.10 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/download/document/BMEx58x0x0_SV04.10/",
"product_ids": [
"97"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMEx58x0x0_SV04.10/"
},
{
"category": "vendor_fix",
"details": "Version SV4.21 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/product-range/62098-modicon-m580-pac-controller/#software-and-firmware Important: customer needs to use version of EcoStruxure\u2122 Control Expert V16.0 HF001 minimum to connect with the latest version of M580 CPU Safety. The software is available for download here: https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#software-and-firmware",
"product_ids": [
"99"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/62098-modicon-m580-pac-controller/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version SV2.21 includes a fix for these vulnerabilities and is available for download here: BMENOC 0301 - https://www.se.com/ww/en/download/document/BMENOC0301_SV_02.21/",
"product_ids": [
"101"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMENOC0301_SV_02.21/"
},
{
"category": "vendor_fix",
"details": "Version SV2.21 includes a fix for these vulnerabilities and is available for download here: BMENOC 0311 -https://www.se.com/ww/en/download/document/BMENOC0311_SV_02.21",
"product_ids": [
"103"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMENOC0311_SV_02.21"
},
{
"category": "vendor_fix",
"details": "Version SV1.09 includes a fix for these vulnerabilities and is available for download here:https://www.se.com/ww/en/download/document/BMENOC0321_SV_01.09",
"product_ids": [
"105"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMENOC0321_SV_01.09"
},
{
"category": "vendor_fix",
"details": "Version SV1.5 of HART X80 Module includes a fix for these vulnerabilities and is available for download here:https://www.se.com/ww/en/download/document/BMEAHO0412_Firmware_upgrade/",
"product_ids": [
"107",
"109"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMEAHO0412_Firmware_upgrade/"
},
{
"category": "vendor_fix",
"details": "Version 1.8 of MC80 Controller (BMKC80) includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/product-range/62396-modicon-mc80/#software-and-firmware",
"product_ids": [
"111"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/62396-modicon-mc80/#software-and-firmware"
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Setup network segmentation and implement a firewall to block all unauthorized access to the device.\u2022 Configure the Access Control List following the recommendations in the device user manual.\u2022 Setup a VPN between the Modicon PLC device and the remote engineering workstations.\u2022 Activate and apply user management and password features.\u2022 Limit the access to both development and control system by physical means, operating system features, etc.",
"product_ids": [
"113"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version SV2.6 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/download/document/Momentum_FW_update/ ",
"product_ids": [
"114"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/Momentum_FW_update/"
},
{
"category": "no_fix_planned",
"details": "Quantum and Premium offers have reached their end of life and are no longer supported.",
"product_ids": [
"116",
"117"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Setup network segmentation and implement a firewall to block all unauthorized access to the device.\u2022 Setup a VPN between the Modicon PLC device and the remote engineering workstations.\u2022 Activate and apply user management and password features.\u2022 Limit the access to both development and control system by physical means, operating system features, etc.Customers should also consider upgrading to the latest product offering Modicon M580 ePAC.",
"product_ids": [
"116",
"117"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 1.60 of BMXNOM0200 includes a fix for these vulnerabilities and is available for download here:https://www.se.com/ww/en/product/BMXNOM0200/ ",
"product_ids": [
"118"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/BMXNOM0200/"
},
{
"category": "vendor_fix",
"details": "Version 1.04 of BMENOS0300 includes a fix for these vulnerabilities and is available for download here:https://www.se.com/ww/en/product/BMENOS0300/",
"product_ids": [
"120"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/BMENOS0300/"
},
{
"category": "vendor_fix",
"details": "Version 10.02 of nanodac includes a fix for this vulnerability and is available for download here: https://www.eurotherm.com/?wpdmdl=28419 Device will reboot automatically after upgrade.",
"product_ids": [
"122"
],
"restart_required": {
"category": "system"
},
"url": "https://www.eurotherm.com/?wpdmdl=28419"
},
{
"category": "vendor_fix",
"details": "Firmware Version 1.66.5.1 of PacDrive Eco/Pro/Pro2 Logic Controllers includes a fix for these vulnerabilities and can be updated through the Schneider Electric Software Update (SESU) application.",
"product_ids": [
"124",
"126",
"128"
],
"restart_required": {
"category": "none"
}
},
{
"category": "no_fix_planned",
"details": "PacDrive M Logic Controller has reached its end of life and is no longer supported.",
"product_ids": [
"130"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside,\u2022 Use firewalls to protect and separate the control system network from other networks,\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required,\u2022 Activate and apply user management and password features,\u2022 Limit the access to both development and control system by physical means, operating system features, etc.Customers should also consider upgrading to the latest product offering PacDrive Eco/Pro/Pro2 to resolve this issue.",
"product_ids": [
"130"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 3.1 of PowerLogic ION7400 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/ION7400_meter_FW_v003.001.000/",
"product_ids": [
"131"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION7400_meter_FW_v003.001.000/"
},
{
"category": "vendor_fix",
"details": "Version 3.1 of PowerLogic PM8000 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/PM8000_meter_FW_v003.001.000/",
"product_ids": [
"133"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/PM8000_meter_FW_v003.001.000/"
},
{
"category": "vendor_fix",
"details": "Version 3.1 of PowerLogic ION9000 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/ION9000_meter_FW_v003.001.000/",
"product_ids": [
"135"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION9000_meter_FW_v003.001.000/"
},
{
"category": "mitigation",
"details": "If the update cannot be applied immediately, please follow the guidelines in Schneider Electric Recommended Cybersecurity Best Practices document to help mitigate the risk.",
"product_ids": [
"131",
"133",
"135"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 4.09.350 of Pro-face GP-Pro EX includes a fix for these vulnerabilities and is available for download here: https://www.proface.com/en/download/trial/gpproex/v40 or update online via GP-Pro EX (refer to Help menu and select \u201cConfirm Update of GP-Pro EX\u201d).To complete the update, connect to Pro-face HMI and download the project file using GP-Pro EX V4.09.350 or later.",
"product_ids": [
"151",
"152",
"153",
"154",
"155"
],
"restart_required": {
"category": "none"
},
"url": "https://www.proface.com/en/download/trial/gpproex/v40"
},
{
"category": "vendor_fix",
"details": "Version 4.09.450 of Pro-face GP-Pro EX includes a fix for these vulnerabilities and is available for download here: https://www.proface.com/en/download/trial/gpproex/v40 or update online via GP-Pro EX (refer to Help menu and select \u201cConfirm Update of GP-Pro EX\u201d). To complete the update, connect to Pro-face HMI and download the project file using GP-Pro EX V4.09.400 or later.",
"product_ids": [
"161"
],
"restart_required": {
"category": "none"
},
"url": "https://www.proface.com/en/download/trial/gpproex/v40"
},
{
"category": "vendor_fix",
"details": "Version 4.09.400 of Pro-face GP-Pro EX includes a fix for these vulnerabilities and is available for download here: https://www.proface.com/en/download/trial/gpproex/v40 or update online via GP-Pro EX (refer to Help menu and select \u201cConfirm Update of GP-Pro EX\u201d). To complete the update, connect to Pro-face HMI and download the project file using GP-Pro EX V4.09.400 or later.",
"product_ids": [
"163",
"164"
],
"restart_required": {
"category": "none"
},
"url": "https://www.proface.com/en/download/trial/gpproex/v40"
},
{
"category": "mitigation",
"details": "Customers should immediately apply the mitigations found in the Cybersecurity Reference Manual linked below to reduce the risk of exploit: https://www.se.com/ww/en/download/document/EIO0000001999/",
"product_ids": [
"167",
"168"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/EIO0000001999/"
},
{
"category": "vendor_fix",
"details": "Version SY-1101207, Version N of SCD6000 firmware includes a fix for this vulnerability. Contact your local Customer Support to receive this firmware version. Reboot is required after installation.",
"product_ids": [
"169"
],
"restart_required": {
"category": "system"
}
},
{
"category": "vendor_fix",
"details": "Version C3414-500-S02K5_P5 of SAGE RTU CPU 3414 includes a fix for this vulnerability and is available for download here: https://www.sage-rtu.com/downloads.html Reboot of SAGE RTU is required after firmware upgrade.This fix applies a Wind River VxWorks (real-time operating system) patch to bring code libraries current to 6.9.4.12 RCPL3 revision. This corrects issues with overflow causing malloc/calloc to return valid pointer when it should return fail indication NULL pointer.",
"product_ids": [
"171"
],
"restart_required": {
"category": "system"
},
"url": "https://www.sage-rtu.com/downloads.html"
},
{
"category": "vendor_fix",
"details": "Version 2.43 of the Versadac scalable data recorder is available and includes a fix for these vulnerabilities.Access to the patch can be obtained through the following link: https://partners.eurotherm.com/member-login",
"product_ids": [
"173"
],
"restart_required": {
"category": "none"
},
"url": "https://partners.eurotherm.com/member-login"
},
{
"category": "vendor_fix",
"details": "Version SV02.80 of BMECRA31210, BMXCRA3120, BMXCRA31210 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product\u0026sourceId=BMXCRA31210",
"product_ids": [
"175",
"177",
"179"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product\u0026sourceId=BMXCRA31210"
},
{
"category": "vendor_fix",
"details": "Version V02.80 of 140CRA31200 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/product/140CRA31200/quantum-rio-drop-e-ip-1ch",
"product_ids": [
"181"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/140CRA31200/quantum-rio-drop-e-ip-1ch"
},
{
"category": "vendor_fix",
"details": "Version V02.80 of 140CRA31908 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/product/140CRA31908/m580-quantum-s908-rio-drop-adapter",
"product_ids": [
"183"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/140CRA31908/m580-quantum-s908-rio-drop-adapter"
},
{
"category": "vendor_fix",
"details": "Version SV2.6 of BMENOP0300 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product\u0026sourceId=BMENOP0300",
"product_ids": [
"185"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product\u0026sourceId=BMENOP0300"
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Setup network segmentation and implement a firewall to block all unauthorized access to the device.\u2022 Configure the Access Control List following the recommendations of the device user manual.\u2022 Setup a VPN between the Modicon. Communication modules and the remote engineering workstations.\u2022 Activate and apply user management and password features.Limit the access to both development and control system by physical means, operating system features, etc.",
"product_ids": [
"187"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit: \u2022 Use relays only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Disable unused network protocol interfaces.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Activate and apply user management and password features.\u2022 Limit the access to the system by physical means.",
"product_ids": [
"188"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Setup network segmentation and implement a firewall to block all unauthorized access to the device.\u2022 Configure the Access Control List following the recommendations of the device user manual.\u2022 Setup a VPN between the EPack device and any remote visualization workstations running iTools.\u2022 Activate and apply user management and password features. Limit the access to both development and control system by physical means, operating system features, etc.",
"product_ids": [
"190"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\u2022 Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\u2022 Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.When remote access is required, use secure methods, such as the Vijeo Connect.",
"product_ids": [
"191"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside,\u2022 Use firewalls to protect and separate the control system network from other networks,\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required,\u2022 Activate and apply user management and password features,\u2022 Limit the access to both development and control system by physical means, operating system features, etc.Customers should also consider upgrading to the latest product offering Modicon M262 to resolve this issue.",
"product_ids": [
"192"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the followingmitigations to reduce the risk of exploit:\u2022 Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\u2022 Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment,and networks.\u2022 Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\u2022 When remote access is required, use secure methods, such as the Pro-face Connect.Customers should also consider upgrading to the latest product offering to resolve this issue. Please contact your sales support about alternative products",
"product_ids": [
"193",
"194",
"195"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Setup network segmentation and implement a firewall to block all unauthorized access to the device.\u2022 Configure the Access Control List following the recommendations of the device user manual.\u2022 Setup a VPN between the 6000-series device and any remote visualization workstations running Bridge.\u2022 Activate and apply user management and password features. Limit the access to both development and control system by physical means, operating system features, etc.",
"product_ids": [
"196",
"197",
"198",
"199",
"200"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"3",
"5",
"7",
"10",
"12",
"17",
"20",
"22",
"23",
"25",
"27",
"29",
"37",
"40",
"43",
"50",
"57",
"67",
"69",
"71",
"73",
"75",
"77",
"79",
"81",
"83",
"85",
"87",
"89",
"91",
"93",
"95",
"97",
"99",
"101",
"103",
"105",
"107",
"109",
"111",
"113",
"114",
"116",
"117",
"118",
"120",
"122",
"124",
"126",
"128",
"130",
"131",
"133",
"135",
"151",
"152",
"153",
"154",
"155",
"161",
"163",
"164",
"167",
"168",
"169",
"171",
"173",
"175",
"177",
"179",
"181",
"183",
"185",
"187",
"188",
"190",
"191",
"192",
"193",
"194",
"195",
"196",
"197",
"198",
"199",
"200"
]
}
],
"title": "CVE-2020-35198"
},
{
"acknowledgments": [
{
"urls": [
"https://us-cert.cisa.gov/ics/advisories/icsa-21-119-04"
]
}
],
"cve": "CVE-2020-28895",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "description",
"text": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2",
"4",
"6",
"9",
"11",
"13",
"18",
"21",
"24",
"26",
"28",
"30",
"38",
"39",
"41",
"42",
"44",
"45",
"51",
"52",
"58",
"59",
"68",
"70",
"72",
"74",
"76",
"78",
"80",
"82",
"84",
"86",
"88",
"90",
"92",
"94",
"96",
"98",
"102",
"104",
"106",
"108",
"110",
"112",
"115",
"119",
"121",
"123",
"125",
"127",
"129",
"132",
"134",
"136",
"156",
"157",
"158",
"159",
"160",
"162",
"165",
"166",
"170",
"172",
"174",
"176",
"178",
"180",
"182",
"184",
"186",
"202"
],
"known_affected": [
"1",
"3",
"5",
"7",
"8",
"10",
"12",
"17",
"20",
"22",
"23",
"25",
"27",
"29",
"37",
"40",
"43",
"50",
"57",
"67",
"69",
"71",
"73",
"75",
"77",
"79",
"81",
"83",
"85",
"87",
"89",
"91",
"93",
"95",
"97",
"99",
"101",
"103",
"105",
"107",
"109",
"111",
"113",
"114",
"116",
"117",
"118",
"120",
"122",
"124",
"126",
"128",
"130",
"131",
"133",
"135",
"151",
"152",
"153",
"154",
"155",
"161",
"163",
"164",
"167",
"168",
"169",
"171",
"173",
"175",
"177",
"179",
"181",
"183",
"185",
"187",
"188",
"189",
"190",
"191",
"192",
"193",
"194",
"195",
"196",
"197",
"198",
"199",
"200"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 1.0.5 of Easergy C5 includes a fix for these vulnerabilities and \nis available through Schneider Electric regional DPACs.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Easergy MiCOM P638 Version 676.701 of the P30 firmware includes a fix for these vulnerabilities and is available on request from Schneider Electric\u2019s Customer Care",
"product_ids": [
"5"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "All other Easergy MiCOM P30 Models: Version 675 and later of the P30 firmware includes a fix for these vulnerabilities and is available on request from Schneider Electric\u2019s Customer Care Center.",
"product_ids": [
"3"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit: \u2022 Use relays only in a protected environment to minimize network exposure and ensure that they are not accessible from outside. \u2022 Disable unused network protocol interfaces. \u2022 Use firewalls to protect and separate the control system network from other networks. \u2022 Activate and apply user management and password features. ",
"product_ids": [
"7"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 01.401.101 of Easergy P5 firmware includes a fix for this vulnerability and is available on request from Schneider Electric\u0027s Customer Care Center. ",
"product_ids": [
"8"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 4.03 of the EPC2000 includes a fix for these vulnerabilities and is available for download here:https://www.eurotherm.com/?wpdmdl=137741",
"product_ids": [
"10"
],
"restart_required": {
"category": "none"
},
"url": "https://www.eurotherm.com/?wpdmdl=137741"
},
{
"category": "vendor_fix",
"details": "Version 5.20 of the EPC3000 includes a fix for these vulnerabilities and is available for download here:https://www.eurotherm.com/?wpdmdl=89545 Device will reboot automatically after upgrade.",
"product_ids": [
"12"
],
"restart_required": {
"category": "system"
},
"url": "https://www.eurotherm.com/?wpdmdl=89545"
},
{
"category": "vendor_fix",
"details": "Version 1.2.1 of Vijeo Designer Basic includes a fix for these vulnerabilities. Please contact your Schneider Electric\u2019s Customer Care Center to obtain the installer. To complete the update, connect to Harmony HMI and download the firmware using Vijeo Designer Basic V1.2.1.",
"product_ids": [
"17",
"20"
],
"restart_required": {
"category": "none"
}
},
{
"category": "no_fix_planned",
"details": "The E+PLC100 product has reached its end of life and is no longer supported.",
"product_ids": [
"22"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Setup network segmentation and implement a firewall to block all unauthorized access to the device.\u2022 Configure the Access Control List following the recommendations of the device user manual.\u2022 Setup a VPN between the E+PLC100 device and any remote visualization workstations running the E+PLC tools.\u2022 Activate and apply user management and password features. Limit the access to both development and control system by physical means, operating system features, etc.",
"product_ids": [
"22"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 1.4.0.0 of the E+PLC400 firmware is available and includes a fix for these vulnerabilities. Please contact the Eurotherm Support team to obtain the firmware update. Please be sure to include the following when contacting the support team:\u2022 End Username, Company, and Email Address\u2022 Serial numbers of the devices to be upgraded\u2022 Current E+PLC400 firmware version",
"product_ids": [
"23"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 1.4.0.0 of the E+PLC400 firmware is available and includes a fix for these vulnerabilities. Please contact the Eurotherm Support team to obtain the firmware update. Please be sure to include the following when contacting the support team:\u2022 End Username, Company, and Email Address\u2022 Serial numbers of the devices to be upgraded\u2022 Current E+PLC400 firmware versionVersion 7.3 of the Eycon firmware is available and includes a fix for these vulnerabilities. Access to the patch can be obtained through the following link: https://partners.eurotherm.com/member-login",
"product_ids": [
"25"
],
"restart_required": {
"category": "none"
},
"url": "https://partners.eurotherm.com/member-login"
},
{
"category": "vendor_fix",
"details": "Version 8.2 of the T2550 firmware is available and includes a fix for these vulnerabilities. Access to the patch can be obtained through the following link: https://partners.eurotherm.com/member-login ",
"product_ids": [
"27"
],
"restart_required": {
"category": "none"
},
"url": "https://partners.eurotherm.com/member-login"
},
{
"category": "vendor_fix",
"details": "Version 6.3 of the T2750 firmware is available and includes a fix for these vulnerabilities. Access to the patch can be obtained through the following link:https://partners.eurotherm.com/member-login",
"product_ids": [
"29"
],
"restart_required": {
"category": "none"
},
"url": "https://partners.eurotherm.com/member-login"
},
{
"category": "vendor_fix",
"details": "Version 6.2 SP11 Multi HotFix 4 of Vijeo Designer includes a fix for these vulnerabilities and can be updated through the Schneider Electric Software Update (SESU) application. On the engineering workstation, update to V6.2 SP11 Multi HotFix 4 (or above) of Vijeo Designer.To complete the update, connect to Harmony HMI and download the project file using Vijeo Designer V6.2 SP11 Multi HotFix 4.",
"product_ids": [
"37",
"40",
"43"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 6.2 SP12 of Vijeo Designer includes a fix for these vulnerabilities and can be updated through the Schneider Electric Software Update (SESU) application. On the engineering workstation, update to V6.2 SP12 (or above) of Vijeo Designer. To complete the update, connect to Harmony HMI and download the project file using Vijeo Designer V6.2 SP12.",
"product_ids": [
"50"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 6.3 SP1 of Vijeo Designer includes a fix for these vulnerabilities and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware On the engineering workstation, update to V6.3 SP1 (or above) of Vijeo Designer. To complete the update, connect to Harmony HMI and download the project file using Vijeo Designer V6.3 SP1.",
"product_ids": [
"57"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/1054-vijeo-designer-hmi-software/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Versions B5.118, D1.92, D4.38, D5.25I and D6.18 of MiCOM C264 include a fix for these vulnerabilities and are available through Schneider Electric regional DPACs.",
"product_ids": [
"67",
"69",
"71",
"73",
"75"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 5.1.9.34 of Modicon M241/M251 Logic Controllers includes a fix for these vulnerabilities.On the engineering workstation, update to latest version of EcoStruxure Machine Expert: https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-somachine/?parent-subcategory-id=5140\u0026filter=business-1-industrial-automation-and-control To complete the update on Modicon M241/M251 Logic Controllers, update to firmware version V5.1.9.34 or higher available within EcoStruxure Machine Expert. A reboot is needed.",
"product_ids": [
"77",
"79"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-somachine/?parent-subcategory-id=5140\u0026filter=business-1-industrial-automation-and-control"
},
{
"category": "vendor_fix",
"details": "Version 5.1.6.1 of Modicon M262 Logic Controllers includes a fix for these vulnerabilities.On the engineering workstation, update to latest version of EcoStruxure Machine Expert: https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-somachine/?parent-subcategory-id=5140\u0026filter=business-1-industrial-automation-and-controlTo complete the update on Modicon M262 Logic Controllers, update to firmware version V5.1.6.1 or higher available within EcoStruxure Machine Expert. A reboot is needed.",
"product_ids": [
"81"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-somachine/?parent-subcategory-id=5140\u0026filter=business-1-industrial-automation-and-control"
},
{
"category": "vendor_fix",
"details": "Firmware Version 5.0.4.18 of Modicon M258/LMC058 logic controllers includes a fix for these vulnerabilities and can be updated through Schneider Electric Software Update (SESU) application.",
"product_ids": [
"83",
"85"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 2.11 of BMXNOC0401 includes a fix for thesevulnerabilities and is available for download here:https://www.se.com/ww/en/product/BMXNOC0401/",
"product_ids": [
"87"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/BMXNOC0401/"
},
{
"category": "vendor_fix",
"details": "Version SV3.50 of BMXNOE0100 (H) includes a fix for thesevulnerabilities and is available for download here:https://www.se.com/ww/en/download/document/BMXNOE0100_SV_03.50/",
"product_ids": [
"89"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMXNOE0100_SV_03.50/"
},
{
"category": "vendor_fix",
"details": "Version SV6.70 of BMXNOE0110 (H) includes a fix for thesevulnerabilities and is available for download here:https://www.se.com/ww/en/download/document/BMXNOE0110_SV_06.70/",
"product_ids": [
"91"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMXNOE0110_SV_06.70/"
},
{
"category": "vendor_fix",
"details": "Version 1.7 IR24 of BMXNOR0200H includes a fix for thesevulnerabilities and is available for download here:https://www.se.com/ww/en/product/BMXNOR0200H/",
"product_ids": [
"93"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/BMXNOR0200H/"
},
{
"category": "vendor_fix",
"details": "Version 3.50 of Modicon M340 includes a fix for these vulnerabilities and is available for download here:https://www.se.com/ww/en/download/document/BMXP34xxxxx_SV_03.50/ ",
"product_ids": [
"95"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMXP34xxxxx_SV_03.50/"
},
{
"category": "vendor_fix",
"details": "Version SV4.10 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/download/document/BMEx58x0x0_SV04.10/",
"product_ids": [
"97"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMEx58x0x0_SV04.10/"
},
{
"category": "vendor_fix",
"details": "Version SV4.21 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/product-range/62098-modicon-m580-pac-controller/#software-and-firmware Important: customer needs to use version of EcoStruxure\u2122 Control Expert V16.0 HF001 minimum to connect with the latest version of M580 CPU Safety. The software is available for download here: https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#software-and-firmware",
"product_ids": [
"99"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/62098-modicon-m580-pac-controller/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version SV2.21 includes a fix for these vulnerabilities and is available for download here: BMENOC 0301 - https://www.se.com/ww/en/download/document/BMENOC0301_SV_02.21/",
"product_ids": [
"101"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMENOC0301_SV_02.21/"
},
{
"category": "vendor_fix",
"details": "Version SV2.21 includes a fix for these vulnerabilities and is available for download here: BMENOC 0311 -https://www.se.com/ww/en/download/document/BMENOC0311_SV_02.21",
"product_ids": [
"103"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMENOC0311_SV_02.21"
},
{
"category": "vendor_fix",
"details": "Version SV1.09 includes a fix for these vulnerabilities and is available for download here:https://www.se.com/ww/en/download/document/BMENOC0321_SV_01.09",
"product_ids": [
"105"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMENOC0321_SV_01.09"
},
{
"category": "vendor_fix",
"details": "Version SV1.5 of HART X80 Module includes a fix for these vulnerabilities and is available for download here:https://www.se.com/ww/en/download/document/BMEAHO0412_Firmware_upgrade/",
"product_ids": [
"107",
"109"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/BMEAHO0412_Firmware_upgrade/"
},
{
"category": "vendor_fix",
"details": "Version 1.8 of MC80 Controller (BMKC80) includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/product-range/62396-modicon-mc80/#software-and-firmware",
"product_ids": [
"111"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/62396-modicon-mc80/#software-and-firmware"
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Setup network segmentation and implement a firewall to block all unauthorized access to the device.\u2022 Configure the Access Control List following the recommendations in the device user manual.\u2022 Setup a VPN between the Modicon PLC device and the remote engineering workstations.\u2022 Activate and apply user management and password features.\u2022 Limit the access to both development and control system by physical means, operating system features, etc.",
"product_ids": [
"113"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version SV2.6 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/download/document/Momentum_FW_update/ ",
"product_ids": [
"114"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/Momentum_FW_update/"
},
{
"category": "no_fix_planned",
"details": "Quantum and Premium offers have reached their end of life and are no longer supported.",
"product_ids": [
"116",
"117"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Setup network segmentation and implement a firewall to block all unauthorized access to the device.\u2022 Setup a VPN between the Modicon PLC device and the remote engineering workstations.\u2022 Activate and apply user management and password features.\u2022 Limit the access to both development and control system by physical means, operating system features, etc.Customers should also consider upgrading to the latest product offering Modicon M580 ePAC.",
"product_ids": [
"116",
"117"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 1.60 of BMXNOM0200 includes a fix for these vulnerabilities and is available for download here:https://www.se.com/ww/en/product/BMXNOM0200/ ",
"product_ids": [
"118"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/BMXNOM0200/"
},
{
"category": "vendor_fix",
"details": "Version 1.04 of BMENOS0300 includes a fix for these vulnerabilities and is available for download here:https://www.se.com/ww/en/product/BMENOS0300/",
"product_ids": [
"120"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/BMENOS0300/"
},
{
"category": "vendor_fix",
"details": "Version 10.02 of nanodac includes a fix for this vulnerability and is available for download here: https://www.eurotherm.com/?wpdmdl=28419 Device will reboot automatically after upgrade.",
"product_ids": [
"122"
],
"restart_required": {
"category": "system"
},
"url": "https://www.eurotherm.com/?wpdmdl=28419"
},
{
"category": "vendor_fix",
"details": "Firmware Version 1.66.5.1 of PacDrive Eco/Pro/Pro2 Logic Controllers includes a fix for these vulnerabilities and can be updated through the Schneider Electric Software Update (SESU) application.",
"product_ids": [
"124",
"126",
"128"
],
"restart_required": {
"category": "none"
}
},
{
"category": "no_fix_planned",
"details": "PacDrive M Logic Controller has reached its end of life and is no longer supported.",
"product_ids": [
"130"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside,\u2022 Use firewalls to protect and separate the control system network from other networks,\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required,\u2022 Activate and apply user management and password features,\u2022 Limit the access to both development and control system by physical means, operating system features, etc.Customers should also consider upgrading to the latest product offering PacDrive Eco/Pro/Pro2 to resolve this issue.",
"product_ids": [
"130"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 3.1 of PowerLogic ION7400 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/ION7400_meter_FW_v003.001.000/",
"product_ids": [
"131"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION7400_meter_FW_v003.001.000/"
},
{
"category": "vendor_fix",
"details": "Version 3.1 of PowerLogic PM8000 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/PM8000_meter_FW_v003.001.000/",
"product_ids": [
"133"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/PM8000_meter_FW_v003.001.000/"
},
{
"category": "vendor_fix",
"details": "Version 3.1 of PowerLogic ION9000 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/ION9000_meter_FW_v003.001.000/",
"product_ids": [
"135"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION9000_meter_FW_v003.001.000/"
},
{
"category": "mitigation",
"details": "If the update cannot be applied immediately, please follow the guidelines in Schneider Electric Recommended Cybersecurity Best Practices document to help mitigate the risk.",
"product_ids": [
"131",
"133",
"135"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 4.09.350 of Pro-face GP-Pro EX includes a fix for these vulnerabilities and is available for download here: https://www.proface.com/en/download/trial/gpproex/v40 or update online via GP-Pro EX (refer to Help menu and select \u201cConfirm Update of GP-Pro EX\u201d).To complete the update, connect to Pro-face HMI and download the project file using GP-Pro EX V4.09.350 or later.",
"product_ids": [
"151",
"152",
"153",
"154",
"155"
],
"restart_required": {
"category": "none"
},
"url": "https://www.proface.com/en/download/trial/gpproex/v40"
},
{
"category": "vendor_fix",
"details": "Version 4.09.450 of Pro-face GP-Pro EX includes a fix for these vulnerabilities and is available for download here: https://www.proface.com/en/download/trial/gpproex/v40 or update online via GP-Pro EX (refer to Help menu and select \u201cConfirm Update of GP-Pro EX\u201d). To complete the update, connect to Pro-face HMI and download the project file using GP-Pro EX V4.09.400 or later.",
"product_ids": [
"161"
],
"restart_required": {
"category": "none"
},
"url": "https://www.proface.com/en/download/trial/gpproex/v40"
},
{
"category": "vendor_fix",
"details": "Version 4.09.400 of Pro-face GP-Pro EX includes a fix for these vulnerabilities and is available for download here: https://www.proface.com/en/download/trial/gpproex/v40 or update online via GP-Pro EX (refer to Help menu and select \u201cConfirm Update of GP-Pro EX\u201d). To complete the update, connect to Pro-face HMI and download the project file using GP-Pro EX V4.09.400 or later.",
"product_ids": [
"163",
"164"
],
"restart_required": {
"category": "none"
},
"url": "https://www.proface.com/en/download/trial/gpproex/v40"
},
{
"category": "mitigation",
"details": "Customers should immediately apply the mitigations found in the Cybersecurity Reference Manual linked below to reduce the risk of exploit: https://www.se.com/ww/en/download/document/EIO0000001999/",
"product_ids": [
"167",
"168"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/EIO0000001999/"
},
{
"category": "vendor_fix",
"details": "Version SY-1101207, Version N of SCD6000 firmware includes a fix for this vulnerability. Contact your local Customer Support to receive this firmware version. Reboot is required after installation.",
"product_ids": [
"169"
],
"restart_required": {
"category": "system"
}
},
{
"category": "vendor_fix",
"details": "Version C3414-500-S02K5_P5 of SAGE RTU CPU 3414 includes a fix for this vulnerability and is available for download here: https://www.sage-rtu.com/downloads.html Reboot of SAGE RTU is required after firmware upgrade.This fix applies a Wind River VxWorks (real-time operating system) patch to bring code libraries current to 6.9.4.12 RCPL3 revision. This corrects issues with overflow causing malloc/calloc to return valid pointer when it should return fail indication NULL pointer.",
"product_ids": [
"171"
],
"restart_required": {
"category": "system"
},
"url": "https://www.sage-rtu.com/downloads.html"
},
{
"category": "vendor_fix",
"details": "Version 2.43 of the Versadac scalable data recorder is available and includes a fix for these vulnerabilities.Access to the patch can be obtained through the following link: https://partners.eurotherm.com/member-login",
"product_ids": [
"173"
],
"restart_required": {
"category": "none"
},
"url": "https://partners.eurotherm.com/member-login"
},
{
"category": "vendor_fix",
"details": "Version SV02.80 of BMECRA31210, BMXCRA3120, BMXCRA31210 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product\u0026sourceId=BMXCRA31210",
"product_ids": [
"175",
"177",
"179"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product\u0026sourceId=BMXCRA31210"
},
{
"category": "vendor_fix",
"details": "Version V02.80 of 140CRA31200 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/product/140CRA31200/quantum-rio-drop-e-ip-1ch",
"product_ids": [
"181"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/140CRA31200/quantum-rio-drop-e-ip-1ch"
},
{
"category": "vendor_fix",
"details": "Version V02.80 of 140CRA31908 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/product/140CRA31908/m580-quantum-s908-rio-drop-adapter",
"product_ids": [
"183"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/140CRA31908/m580-quantum-s908-rio-drop-adapter"
},
{
"category": "vendor_fix",
"details": "Version SV2.6 of BMENOP0300 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product\u0026sourceId=BMENOP0300",
"product_ids": [
"185"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product\u0026sourceId=BMENOP0300"
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Setup network segmentation and implement a firewall to block all unauthorized access to the device.\u2022 Configure the Access Control List following the recommendations of the device user manual.\u2022 Setup a VPN between the Modicon. Communication modules and the remote engineering workstations.\u2022 Activate and apply user management and password features.Limit the access to both development and control system by physical means, operating system features, etc.",
"product_ids": [
"187"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit: \u2022 Use relays only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\u2022 Disable unused network protocol interfaces.\u2022 Use firewalls to protect and separate the control system network from other networks.\u2022 Activate and apply user management and password features.\u2022 Limit the access to the system by physical means.",
"product_ids": [
"188",
"189"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Setup network segmentation and implement a firewall to block all unauthorized access to the device.\u2022 Configure the Access Control List following the recommendations of the device user manual.\u2022 Setup a VPN between the EPack device and any remote visualization workstations running iTools.\u2022 Activate and apply user management and password features. Limit the access to both development and control system by physical means, operating system features, etc.",
"product_ids": [
"190"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\u2022 Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\u2022 Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.When remote access is required, use secure methods, such as the Vijeo Connect.",
"product_ids": [
"191"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside,\u2022 Use firewalls to protect and separate the control system network from other networks,\u2022 Use VPN (Virtual Private Networks) tunnels if remote access is required,\u2022 Activate and apply user management and password features,\u2022 Limit the access to both development and control system by physical means, operating system features, etc.Customers should also consider upgrading to the latest product offering Modicon M262 to resolve this issue.",
"product_ids": [
"192"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the followingmitigations to reduce the risk of exploit:\u2022 Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\u2022 Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment,and networks.\u2022 Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\u2022 When remote access is required, use secure methods, such as the Pro-face Connect.Customers should also consider upgrading to the latest product offering to resolve this issue. Please contact your sales support about alternative products",
"product_ids": [
"193",
"194",
"195"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:\u2022 Setup network segmentation and implement a firewall to block all unauthorized access to the device.\u2022 Configure the Access Control List following the recommendations of the device user manual.\u2022 Setup a VPN between the 6000-series device and any remote visualization workstations running Bridge.\u2022 Activate and apply user management and password features. Limit the access to both development and control system by physical means, operating system features, etc.",
"product_ids": [
"196",
"197",
"198",
"199",
"200"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"products": [
"1",
"3",
"5",
"7",
"8",
"10",
"12",
"17",
"20",
"22",
"23",
"25",
"27",
"29",
"37",
"40",
"43",
"50",
"57",
"67",
"69",
"71",
"73",
"75",
"77",
"79",
"81",
"83",
"85",
"87",
"89",
"91",
"93",
"95",
"97",
"99",
"101",
"103",
"105",
"107",
"109",
"111",
"113",
"114",
"116",
"117",
"118",
"120",
"122",
"124",
"126",
"128",
"130",
"131",
"133",
"135",
"151",
"152",
"153",
"154",
"155",
"161",
"163",
"164",
"167",
"168",
"169",
"171",
"173",
"175",
"177",
"179",
"181",
"183",
"185",
"187",
"188",
"189",
"190",
"191",
"192",
"193",
"194",
"195",
"196",
"197",
"198",
"199",
"200"
]
}
],
"title": "CVE-2020-28895"
},
{
"acknowledgments": [
{
"urls": [
"https://us-cert.cisa.gov/ics/advisories/icsa-21-119-04"
]
}
],
"cve": "CVE-2021-22156",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "description",
"text": "An integer overflow vulnerability in the calloc() function of the C runtime library of affected versions of BlackBerry\u00ae QNX Software Development Platform (SDP) version(s) 6.5.0SP1 and earlier, QNX OS for Medical 1.1 and earlier, and QNX OS for Safety 1.0.1 and earlier that could allow an attacker to potentially perform a denial of service or execute arbitrary code.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"66"
],
"known_affected": [
"64"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Updates have been released to address the identified vulnerability Customers are urged to upgrade to Niagara 4.10u1.\nThese updates are available on the Schneider Electric Exchange https://ecoxpert.se.com/ or by contacting your sales support channel or by contacting the Schneider Electric support team at productsupport.NAM-BMS@schneider-electric.com It is important that all TAC I/A Series Niagara customers for all supported platforms update their systems with these releases to mitigate risk. If you have any questions, please contact your Schneider Electric support team at productsupport.NAM-BMS@schneider-electric.com. As always, we highly recommend that TAC I/A Series Niagara customers running on an unsupported platform (such as Niagara G3/AX) take action to update their systems to a supported platform, ideally the 4.10u1 release of Niagara Framework. In addition to updating your system, Schneider Electric recommends that customers with affected products take the following steps to protect themselves:\n\u2022 Review and validate the list of users who are authorized and who can authenticate to Niagara.\n\u2022 Allow only trained and trusted persons to have physical access to the system, including devices that have connection to the system though the Ethernet port.\n\u2022 Consider using a VPN or other means to ensure secure remote connections into the network where the system is located, If remote connections are enabled.\n\u2022 Sign all modules and program objects provided by third-party teams. \nReview the Niagara Hardening Guide https://community.exchange.se.com/t5/Building-Automation-Knowledge/I-A-Series-Niagara-4-Hardening-Guide-Tips-to-Secure-an-I-A/ta-p/159287 for techniques on securing your installation.",
"product_ids": [
"64"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"64"
]
}
],
"title": "CVE-2021-22156"
}
]
}
SSA-813746
Vulnerability from csaf_siemens - Published: 2023-04-11 00:00 - Updated: 2024-08-13 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)
Siemens / SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)
|
6GK5200-4AH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)
Siemens / SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)
|
6GK5201-3BH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)
Siemens / SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)
|
6GK5201-3JR00-2BA6
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)
Siemens / SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)
|
6GK5202-2BB00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)
Siemens / SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)
|
6GK5202-2BB10-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)
Siemens / SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)
|
6GK5202-2BH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)
Siemens / SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)
|
6GK5202-2JR00-2BA6
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X204-2 (6GK5204-2BB10-2AA3)
Siemens / SCALANCE X204-2 (6GK5204-2BB10-2AA3)
|
6GK5204-2BB10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2FM (6GK5204-2BB11-2AA3)
Siemens / SCALANCE X204-2FM (6GK5204-2BB11-2AA3)
|
6GK5204-2BB11-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2LD (6GK5204-2BC10-2AA3)
Siemens / SCALANCE X204-2LD (6GK5204-2BC10-2AA3)
|
6GK5204-2BC10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)
Siemens / SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)
|
6GK5204-2BC10-2CA2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2TS (6GK5204-2BB10-2CA2)
Siemens / SCALANCE X204-2TS (6GK5204-2BB10-2CA2)
|
6GK5204-2BB10-2CA2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204IRT (6GK5204-0BA00-2BA3)
Siemens / SCALANCE X204IRT (6GK5204-0BA00-2BA3)
|
6GK5204-0BA00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X204IRT (6GK5204-0BA10-2BA3)
Siemens / SCALANCE X204IRT (6GK5204-0BA10-2BA3)
|
6GK5204-0BA10-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)
Siemens / SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)
|
6GK5204-0JA00-2BA6
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X206-1 (6GK5206-1BB10-2AA3)
Siemens / SCALANCE X206-1 (6GK5206-1BB10-2AA3)
|
6GK5206-1BB10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X206-1LD (6GK5206-1BC10-2AA3)
Siemens / SCALANCE X206-1LD (6GK5206-1BC10-2AA3)
|
6GK5206-1BC10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X208 (6GK5208-0BA10-2AA3)
Siemens / SCALANCE X208 (6GK5208-0BA10-2AA3)
|
6GK5208-0BA10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X208PRO (6GK5208-0HA10-2AA6)
Siemens / SCALANCE X208PRO (6GK5208-0HA10-2AA6)
|
6GK5208-0HA10-2AA6
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X212-2 (6GK5212-2BB00-2AA3)
Siemens / SCALANCE X212-2 (6GK5212-2BB00-2AA3)
|
6GK5212-2BB00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X212-2LD (6GK5212-2BC00-2AA3)
Siemens / SCALANCE X212-2LD (6GK5212-2BC00-2AA3)
|
6GK5212-2BC00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X216 (6GK5216-0BA00-2AA3)
Siemens / SCALANCE X216 (6GK5216-0BA00-2AA3)
|
6GK5216-0BA00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X224 (6GK5224-0BA00-2AA3)
Siemens / SCALANCE X224 (6GK5224-0BA00-2AA3)
|
6GK5224-0BA00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)
Siemens / SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)
|
6GK5302-7GD00-3GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)
Siemens / SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)
|
6GK5302-7GD00-3EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)
Siemens / SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)
|
6GK5302-7GD00-1GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)
Siemens / SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)
|
6GK5302-7GD00-1EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)
Siemens / SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)
|
6GK5302-7GD00-4GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)
Siemens / SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)
|
6GK5302-7GD00-4EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)
Siemens / SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)
|
6GK5302-7GD00-2GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)
Siemens / SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)
|
6GK5302-7GD00-2EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X304-2FE (6GK5304-2BD00-2AA3)
Siemens / SCALANCE X304-2FE (6GK5304-2BD00-2AA3)
|
6GK5304-2BD00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)
Siemens / SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)
|
6GK5306-1BF00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)
Siemens / SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)
|
6GK5307-2FD00-3GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)
Siemens / SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)
|
6GK5307-2FD00-3EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)
Siemens / SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)
|
6GK5307-2FD00-1GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)
Siemens / SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)
|
6GK5307-2FD00-1EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)
Siemens / SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)
|
6GK5307-2FD00-4GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)
Siemens / SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)
|
6GK5307-2FD00-4EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)
Siemens / SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)
|
6GK5307-2FD00-2GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)
Siemens / SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)
|
6GK5307-2FD00-2EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3 (6GK5307-3BL00-2AA3)
Siemens / SCALANCE X307-3 (6GK5307-3BL00-2AA3)
|
6GK5307-3BL00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3 (6GK5307-3BL10-2AA3)
Siemens / SCALANCE X307-3 (6GK5307-3BL10-2AA3)
|
6GK5307-3BL10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3LD (6GK5307-3BM00-2AA3)
Siemens / SCALANCE X307-3LD (6GK5307-3BM00-2AA3)
|
6GK5307-3BM00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3LD (6GK5307-3BM10-2AA3)
Siemens / SCALANCE X307-3LD (6GK5307-3BM10-2AA3)
|
6GK5307-3BM10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2 (6GK5308-2FL00-2AA3)
Siemens / SCALANCE X308-2 (6GK5308-2FL00-2AA3)
|
6GK5308-2FL00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2 (6GK5308-2FL10-2AA3)
Siemens / SCALANCE X308-2 (6GK5308-2FL10-2AA3)
|
6GK5308-2FL10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LD (6GK5308-2FM00-2AA3)
Siemens / SCALANCE X308-2LD (6GK5308-2FM00-2AA3)
|
6GK5308-2FM00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LD (6GK5308-2FM10-2AA3)
Siemens / SCALANCE X308-2LD (6GK5308-2FM10-2AA3)
|
6GK5308-2FM10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH (6GK5308-2FN00-2AA3)
Siemens / SCALANCE X308-2LH (6GK5308-2FN00-2AA3)
|
6GK5308-2FN00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH (6GK5308-2FN10-2AA3)
Siemens / SCALANCE X308-2LH (6GK5308-2FN10-2AA3)
|
6GK5308-2FN10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)
Siemens / SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)
|
6GK5308-2FP00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)
Siemens / SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)
|
6GK5308-2FP10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M (6GK5308-2GG00-2AA2)
Siemens / SCALANCE X308-2M (6GK5308-2GG00-2AA2)
|
6GK5308-2GG00-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M (6GK5308-2GG10-2AA2)
Siemens / SCALANCE X308-2M (6GK5308-2GG10-2AA2)
|
6GK5308-2GG10-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)
Siemens / SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)
|
6GK5308-2QG00-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)
Siemens / SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)
|
6GK5308-2QG10-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)
Siemens / SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)
|
6GK5308-2GG00-2CA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)
Siemens / SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)
|
6GK5308-2GG10-2CA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310 (6GK5310-0FA00-2AA3)
Siemens / SCALANCE X310 (6GK5310-0FA00-2AA3)
|
6GK5310-0FA00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310 (6GK5310-0FA10-2AA3)
Siemens / SCALANCE X310 (6GK5310-0FA10-2AA3)
|
6GK5310-0FA10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310FE (6GK5310-0BA00-2AA3)
Siemens / SCALANCE X310FE (6GK5310-0BA00-2AA3)
|
6GK5310-0BA00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310FE (6GK5310-0BA10-2AA3)
Siemens / SCALANCE X310FE (6GK5310-0BA10-2AA3)
|
6GK5310-0BA10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)
Siemens / SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)
|
6GK5320-1BD00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)
Siemens / SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)
|
6GK5320-3BF00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X408-2 (6GK5408-2FD00-2AA2)
Siemens / SCALANCE X408-2 (6GK5408-2FD00-2AA2)
|
6GK5408-2FD00-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)
Siemens / SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)
|
6GK5201-3BH00-2BD2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)
Siemens / SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)
|
6GK5202-2BH00-2BD2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF204 (6GK5204-0BA00-2AF2)
Siemens / SCALANCE XF204 (6GK5204-0BA00-2AF2)
|
6GK5204-0BA00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XF204-2 (6GK5204-2BC00-2AF2)
Siemens / SCALANCE XF204-2 (6GK5204-2BC00-2AF2)
|
6GK5204-2BC00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)
Siemens / SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)
|
6GK5204-2AA00-2BD2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF204IRT (6GK5204-0BA00-2BF2)
Siemens / SCALANCE XF204IRT (6GK5204-0BA00-2BF2)
|
6GK5204-0BA00-2BF2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF206-1 (6GK5206-1BC00-2AF2)
Siemens / SCALANCE XF206-1 (6GK5206-1BC00-2AF2)
|
6GK5206-1BC00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XF208 (6GK5208-0BA00-2AF2)
Siemens / SCALANCE XF208 (6GK5208-0BA00-2AF2)
|
6GK5208-0BA00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)
Siemens / SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)
|
6GK5324-0GG00-3AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)
Siemens / SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)
|
6GK5324-0GG10-3AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)
Siemens / SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)
|
6GK5324-0GG00-3HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)
Siemens / SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)
|
6GK5324-0GG10-3HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)
Siemens / SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)
|
6GK5324-0GG00-1AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)
Siemens / SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)
|
6GK5324-0GG10-1AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)
Siemens / SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)
|
6GK5324-0GG00-1HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)
Siemens / SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)
|
6GK5324-0GG10-1HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)
Siemens / SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)
|
6GK5324-0GG00-1CR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)
Siemens / SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)
|
6GK5324-0GG10-1CR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)
|
6GK5324-4GG00-3ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)
|
6GK5324-4GG10-3ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)
|
6GK5324-4GG00-3JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)
|
6GK5324-4GG10-3JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)
|
6GK5324-4GG00-1ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)
|
6GK5324-4GG10-1ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)
|
6GK5324-4GG00-1JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)
|
6GK5324-4GG10-1JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)
|
6GK5324-4GG00-4ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)
|
6GK5324-4GG10-4ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)
|
6GK5324-4GG00-4JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)
|
6GK5324-4GG10-4JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)
|
6GK5324-4GG00-2ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)
|
6GK5324-4GG10-2ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)
|
6GK5324-4GG00-2JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)
|
6GK5324-4GG10-2JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)
Siemens / SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)
|
6GK5324-4QG00-3AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)
Siemens / SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)
|
6GK5324-4QG00-3HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)
Siemens / SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)
|
6GK5324-4QG00-1AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)
Siemens / SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)
|
6GK5324-4QG00-1HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)
Siemens / SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)
|
6GK5324-4QG00-1CR2
|
vers:all/* |
No Fix Planned
|
|
SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)
Siemens / SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)
|
6AG1202-2BH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)
Siemens / SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)
|
6AG1308-2FL10-4AA3
|
vers:all/* |
No Fix Planned
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)
Siemens / SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)
|
6GK5200-4AH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)
Siemens / SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)
|
6GK5201-3BH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)
Siemens / SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)
|
6GK5201-3JR00-2BA6
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)
Siemens / SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)
|
6GK5202-2BB00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)
Siemens / SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)
|
6GK5202-2BB10-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)
Siemens / SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)
|
6GK5202-2BH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)
Siemens / SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)
|
6GK5202-2JR00-2BA6
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X204-2 (6GK5204-2BB10-2AA3)
Siemens / SCALANCE X204-2 (6GK5204-2BB10-2AA3)
|
6GK5204-2BB10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2FM (6GK5204-2BB11-2AA3)
Siemens / SCALANCE X204-2FM (6GK5204-2BB11-2AA3)
|
6GK5204-2BB11-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2LD (6GK5204-2BC10-2AA3)
Siemens / SCALANCE X204-2LD (6GK5204-2BC10-2AA3)
|
6GK5204-2BC10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)
Siemens / SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)
|
6GK5204-2BC10-2CA2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204-2TS (6GK5204-2BB10-2CA2)
Siemens / SCALANCE X204-2TS (6GK5204-2BB10-2CA2)
|
6GK5204-2BB10-2CA2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X204IRT (6GK5204-0BA00-2BA3)
Siemens / SCALANCE X204IRT (6GK5204-0BA00-2BA3)
|
6GK5204-0BA00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X204IRT (6GK5204-0BA10-2BA3)
Siemens / SCALANCE X204IRT (6GK5204-0BA10-2BA3)
|
6GK5204-0BA10-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)
Siemens / SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)
|
6GK5204-0JA00-2BA6
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE X206-1 (6GK5206-1BB10-2AA3)
Siemens / SCALANCE X206-1 (6GK5206-1BB10-2AA3)
|
6GK5206-1BB10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X206-1LD (6GK5206-1BC10-2AA3)
Siemens / SCALANCE X206-1LD (6GK5206-1BC10-2AA3)
|
6GK5206-1BC10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X208 (6GK5208-0BA10-2AA3)
Siemens / SCALANCE X208 (6GK5208-0BA10-2AA3)
|
6GK5208-0BA10-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X208PRO (6GK5208-0HA10-2AA6)
Siemens / SCALANCE X208PRO (6GK5208-0HA10-2AA6)
|
6GK5208-0HA10-2AA6
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X212-2 (6GK5212-2BB00-2AA3)
Siemens / SCALANCE X212-2 (6GK5212-2BB00-2AA3)
|
6GK5212-2BB00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X212-2LD (6GK5212-2BC00-2AA3)
Siemens / SCALANCE X212-2LD (6GK5212-2BC00-2AA3)
|
6GK5212-2BC00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X216 (6GK5216-0BA00-2AA3)
Siemens / SCALANCE X216 (6GK5216-0BA00-2AA3)
|
6GK5216-0BA00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X224 (6GK5224-0BA00-2AA3)
Siemens / SCALANCE X224 (6GK5224-0BA00-2AA3)
|
6GK5224-0BA00-2AA3
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)
Siemens / SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)
|
6GK5302-7GD00-3GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)
Siemens / SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)
|
6GK5302-7GD00-3EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)
Siemens / SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)
|
6GK5302-7GD00-1GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)
Siemens / SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)
|
6GK5302-7GD00-1EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)
Siemens / SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)
|
6GK5302-7GD00-4GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)
Siemens / SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)
|
6GK5302-7GD00-4EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)
Siemens / SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)
|
6GK5302-7GD00-2GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)
Siemens / SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)
|
6GK5302-7GD00-2EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X304-2FE (6GK5304-2BD00-2AA3)
Siemens / SCALANCE X304-2FE (6GK5304-2BD00-2AA3)
|
6GK5304-2BD00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)
Siemens / SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)
|
6GK5306-1BF00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)
Siemens / SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)
|
6GK5307-2FD00-3GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)
Siemens / SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)
|
6GK5307-2FD00-3EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)
Siemens / SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)
|
6GK5307-2FD00-1GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)
Siemens / SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)
|
6GK5307-2FD00-1EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)
Siemens / SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)
|
6GK5307-2FD00-4GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)
Siemens / SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)
|
6GK5307-2FD00-4EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)
Siemens / SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)
|
6GK5307-2FD00-2GA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)
Siemens / SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)
|
6GK5307-2FD00-2EA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3 (6GK5307-3BL00-2AA3)
Siemens / SCALANCE X307-3 (6GK5307-3BL00-2AA3)
|
6GK5307-3BL00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3 (6GK5307-3BL10-2AA3)
Siemens / SCALANCE X307-3 (6GK5307-3BL10-2AA3)
|
6GK5307-3BL10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3LD (6GK5307-3BM00-2AA3)
Siemens / SCALANCE X307-3LD (6GK5307-3BM00-2AA3)
|
6GK5307-3BM00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X307-3LD (6GK5307-3BM10-2AA3)
Siemens / SCALANCE X307-3LD (6GK5307-3BM10-2AA3)
|
6GK5307-3BM10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2 (6GK5308-2FL00-2AA3)
Siemens / SCALANCE X308-2 (6GK5308-2FL00-2AA3)
|
6GK5308-2FL00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2 (6GK5308-2FL10-2AA3)
Siemens / SCALANCE X308-2 (6GK5308-2FL10-2AA3)
|
6GK5308-2FL10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LD (6GK5308-2FM00-2AA3)
Siemens / SCALANCE X308-2LD (6GK5308-2FM00-2AA3)
|
6GK5308-2FM00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LD (6GK5308-2FM10-2AA3)
Siemens / SCALANCE X308-2LD (6GK5308-2FM10-2AA3)
|
6GK5308-2FM10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH (6GK5308-2FN00-2AA3)
Siemens / SCALANCE X308-2LH (6GK5308-2FN00-2AA3)
|
6GK5308-2FN00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH (6GK5308-2FN10-2AA3)
Siemens / SCALANCE X308-2LH (6GK5308-2FN10-2AA3)
|
6GK5308-2FN10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)
Siemens / SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)
|
6GK5308-2FP00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)
Siemens / SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)
|
6GK5308-2FP10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M (6GK5308-2GG00-2AA2)
Siemens / SCALANCE X308-2M (6GK5308-2GG00-2AA2)
|
6GK5308-2GG00-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M (6GK5308-2GG10-2AA2)
Siemens / SCALANCE X308-2M (6GK5308-2GG10-2AA2)
|
6GK5308-2GG10-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)
Siemens / SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)
|
6GK5308-2QG00-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)
Siemens / SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)
|
6GK5308-2QG10-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)
Siemens / SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)
|
6GK5308-2GG00-2CA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)
Siemens / SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)
|
6GK5308-2GG10-2CA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310 (6GK5310-0FA00-2AA3)
Siemens / SCALANCE X310 (6GK5310-0FA00-2AA3)
|
6GK5310-0FA00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310 (6GK5310-0FA10-2AA3)
Siemens / SCALANCE X310 (6GK5310-0FA10-2AA3)
|
6GK5310-0FA10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310FE (6GK5310-0BA00-2AA3)
Siemens / SCALANCE X310FE (6GK5310-0BA00-2AA3)
|
6GK5310-0BA00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X310FE (6GK5310-0BA10-2AA3)
Siemens / SCALANCE X310FE (6GK5310-0BA10-2AA3)
|
6GK5310-0BA10-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)
Siemens / SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)
|
6GK5320-1BD00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)
Siemens / SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)
|
6GK5320-3BF00-2AA3
|
vers:all/* |
No Fix Planned
|
|
SCALANCE X408-2 (6GK5408-2FD00-2AA2)
Siemens / SCALANCE X408-2 (6GK5408-2FD00-2AA2)
|
6GK5408-2FD00-2AA2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)
Siemens / SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)
|
6GK5201-3BH00-2BD2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)
Siemens / SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)
|
6GK5202-2BH00-2BD2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF204 (6GK5204-0BA00-2AF2)
Siemens / SCALANCE XF204 (6GK5204-0BA00-2AF2)
|
6GK5204-0BA00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XF204-2 (6GK5204-2BC00-2AF2)
Siemens / SCALANCE XF204-2 (6GK5204-2BC00-2AF2)
|
6GK5204-2BC00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)
Siemens / SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)
|
6GK5204-2AA00-2BD2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF204IRT (6GK5204-0BA00-2BF2)
Siemens / SCALANCE XF204IRT (6GK5204-0BA00-2BF2)
|
6GK5204-0BA00-2BF2
|
<V5.5.2 |
Vendor Fix
fix
|
|
SCALANCE XF206-1 (6GK5206-1BC00-2AF2)
Siemens / SCALANCE XF206-1 (6GK5206-1BC00-2AF2)
|
6GK5206-1BC00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XF208 (6GK5208-0BA00-2AF2)
Siemens / SCALANCE XF208 (6GK5208-0BA00-2AF2)
|
6GK5208-0BA00-2AF2
|
<V5.2.6 |
Vendor Fix
fix
|
|
SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)
Siemens / SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)
|
6GK5324-0GG00-3AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)
Siemens / SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)
|
6GK5324-0GG10-3AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)
Siemens / SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)
|
6GK5324-0GG00-3HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)
Siemens / SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)
|
6GK5324-0GG10-3HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)
Siemens / SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)
|
6GK5324-0GG00-1AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)
Siemens / SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)
|
6GK5324-0GG10-1AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)
Siemens / SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)
|
6GK5324-0GG00-1HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)
Siemens / SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)
|
6GK5324-0GG10-1HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)
Siemens / SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)
|
6GK5324-0GG00-1CR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)
Siemens / SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)
|
6GK5324-0GG10-1CR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)
|
6GK5324-4GG00-3ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)
|
6GK5324-4GG10-3ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)
|
6GK5324-4GG00-3JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)
Siemens / SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)
|
6GK5324-4GG10-3JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)
|
6GK5324-4GG00-1ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)
|
6GK5324-4GG10-1ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)
|
6GK5324-4GG00-1JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)
Siemens / SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)
|
6GK5324-4GG10-1JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)
|
6GK5324-4GG00-4ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)
|
6GK5324-4GG10-4ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)
|
6GK5324-4GG00-4JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)
Siemens / SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)
|
6GK5324-4GG10-4JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)
|
6GK5324-4GG00-2ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)
|
6GK5324-4GG10-2ER2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)
|
6GK5324-4GG00-2JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)
Siemens / SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)
|
6GK5324-4GG10-2JR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)
Siemens / SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)
|
6GK5324-4QG00-3AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)
Siemens / SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)
|
6GK5324-4QG00-3HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)
Siemens / SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)
|
6GK5324-4QG00-1AR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)
Siemens / SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)
|
6GK5324-4QG00-1HR2
|
vers:all/* |
No Fix Planned
|
|
SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)
Siemens / SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)
|
6GK5324-4QG00-1CR2
|
vers:all/* |
No Fix Planned
|
|
SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)
Siemens / SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)
|
6AG1202-2BH00-2BA3
|
<V5.5.2 |
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)
Siemens / SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)
|
6AG1308-2FL10-4AA3
|
vers:all/* |
No Fix Planned
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Siemens has released a new firmware version for SCALANCE X-200 and X-200 IRT switches that address Bad Alloc vulnerabilities in the underlying operating system and recommends to update to the latest versions. Siemens recommends countermeasures for products where updates are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-813746: BadAlloc Vulnerabilities in SCALANCE X-200, X-200IRT, and X-300 Switch Families - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-813746.html"
},
{
"category": "self",
"summary": "SSA-813746: BadAlloc Vulnerabilities in SCALANCE X-200, X-200IRT, and X-300 Switch Families - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-813746.json"
}
],
"title": "SSA-813746: BadAlloc Vulnerabilities in SCALANCE X-200, X-200IRT, and X-300 Switch Families",
"tracking": {
"current_release_date": "2024-08-13T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-813746",
"initial_release_date": "2023-04-11T00:00:00Z",
"revision_history": [
{
"date": "2023-04-11T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2024-08-13T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Updated description and CVSS for CVE-2020-35198"
}
],
"status": "interim",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"6GK5200-4AH00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)",
"product_id": "2",
"product_identification_helper": {
"model_numbers": [
"6GK5201-3BH00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)",
"product_id": "3",
"product_identification_helper": {
"model_numbers": [
"6GK5201-3JR00-2BA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)",
"product_id": "4",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2BB00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)",
"product_id": "5",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2BB10-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)",
"product_id": "6",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2BH00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)",
"product_id": "7",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2JR00-2BA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X204-2 (6GK5204-2BB10-2AA3)",
"product_id": "8",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2BB10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204-2 (6GK5204-2BB10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X204-2FM (6GK5204-2BB11-2AA3)",
"product_id": "9",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2BB11-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204-2FM (6GK5204-2BB11-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X204-2LD (6GK5204-2BC10-2AA3)",
"product_id": "10",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2BC10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204-2LD (6GK5204-2BC10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)",
"product_id": "11",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2BC10-2CA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X204-2TS (6GK5204-2BB10-2CA2)",
"product_id": "12",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2BB10-2CA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204-2TS (6GK5204-2BB10-2CA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X204IRT (6GK5204-0BA00-2BA3)",
"product_id": "13",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204IRT (6GK5204-0BA00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X204IRT (6GK5204-0BA10-2BA3)",
"product_id": "14",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA10-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204IRT (6GK5204-0BA10-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)",
"product_id": "15",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0JA00-2BA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X206-1 (6GK5206-1BB10-2AA3)",
"product_id": "16",
"product_identification_helper": {
"model_numbers": [
"6GK5206-1BB10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X206-1 (6GK5206-1BB10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X206-1LD (6GK5206-1BC10-2AA3)",
"product_id": "17",
"product_identification_helper": {
"model_numbers": [
"6GK5206-1BC10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X206-1LD (6GK5206-1BC10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X208 (6GK5208-0BA10-2AA3)",
"product_id": "18",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X208 (6GK5208-0BA10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X208PRO (6GK5208-0HA10-2AA6)",
"product_id": "19",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0HA10-2AA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X208PRO (6GK5208-0HA10-2AA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X212-2 (6GK5212-2BB00-2AA3)",
"product_id": "20",
"product_identification_helper": {
"model_numbers": [
"6GK5212-2BB00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X212-2 (6GK5212-2BB00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X212-2LD (6GK5212-2BC00-2AA3)",
"product_id": "21",
"product_identification_helper": {
"model_numbers": [
"6GK5212-2BC00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X212-2LD (6GK5212-2BC00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X216 (6GK5216-0BA00-2AA3)",
"product_id": "22",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0BA00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X216 (6GK5216-0BA00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE X224 (6GK5224-0BA00-2AA3)",
"product_id": "23",
"product_identification_helper": {
"model_numbers": [
"6GK5224-0BA00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X224 (6GK5224-0BA00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)",
"product_id": "24",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-2EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)",
"product_id": "25",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-2GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)",
"product_id": "26",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-4EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)",
"product_id": "27",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-4GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)",
"product_id": "28",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-1EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)",
"product_id": "29",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-1GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)",
"product_id": "30",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-3EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)",
"product_id": "31",
"product_identification_helper": {
"model_numbers": [
"6GK5302-7GD00-3GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X304-2FE (6GK5304-2BD00-2AA3)",
"product_id": "32",
"product_identification_helper": {
"model_numbers": [
"6GK5304-2BD00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X304-2FE (6GK5304-2BD00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)",
"product_id": "33",
"product_identification_helper": {
"model_numbers": [
"6GK5306-1BF00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)",
"product_id": "34",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-2EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)",
"product_id": "35",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-2GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)",
"product_id": "36",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-4EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)",
"product_id": "37",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-4GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)",
"product_id": "38",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-1EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)",
"product_id": "39",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-1GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)",
"product_id": "40",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-3EA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)",
"product_id": "41",
"product_identification_helper": {
"model_numbers": [
"6GK5307-2FD00-3GA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-3 (6GK5307-3BL00-2AA3)",
"product_id": "42",
"product_identification_helper": {
"model_numbers": [
"6GK5307-3BL00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-3 (6GK5307-3BL00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-3 (6GK5307-3BL10-2AA3)",
"product_id": "43",
"product_identification_helper": {
"model_numbers": [
"6GK5307-3BL10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-3 (6GK5307-3BL10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-3LD (6GK5307-3BM00-2AA3)",
"product_id": "44",
"product_identification_helper": {
"model_numbers": [
"6GK5307-3BM00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-3LD (6GK5307-3BM00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X307-3LD (6GK5307-3BM10-2AA3)",
"product_id": "45",
"product_identification_helper": {
"model_numbers": [
"6GK5307-3BM10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X307-3LD (6GK5307-3BM10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2 (6GK5308-2FL00-2AA3)",
"product_id": "46",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FL00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2 (6GK5308-2FL00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2 (6GK5308-2FL10-2AA3)",
"product_id": "47",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FL10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2 (6GK5308-2FL10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2LD (6GK5308-2FM00-2AA3)",
"product_id": "48",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FM00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LD (6GK5308-2FM00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2LD (6GK5308-2FM10-2AA3)",
"product_id": "49",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FM10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LD (6GK5308-2FM10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2LH (6GK5308-2FN00-2AA3)",
"product_id": "50",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FN00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LH (6GK5308-2FN00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2LH (6GK5308-2FN10-2AA3)",
"product_id": "51",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FN10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LH (6GK5308-2FN10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)",
"product_id": "52",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FP00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)",
"product_id": "53",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2FP10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2M (6GK5308-2GG00-2AA2)",
"product_id": "54",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2GG00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M (6GK5308-2GG00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2M (6GK5308-2GG10-2AA2)",
"product_id": "55",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2GG10-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M (6GK5308-2GG10-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)",
"product_id": "56",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2QG00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)",
"product_id": "57",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2QG10-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)",
"product_id": "58",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2GG00-2CA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M TS (6GK5308-2GG00-2CA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)",
"product_id": "59",
"product_identification_helper": {
"model_numbers": [
"6GK5308-2GG10-2CA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X308-2M TS (6GK5308-2GG10-2CA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X310 (6GK5310-0FA00-2AA3)",
"product_id": "60",
"product_identification_helper": {
"model_numbers": [
"6GK5310-0FA00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X310 (6GK5310-0FA00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X310 (6GK5310-0FA10-2AA3)",
"product_id": "61",
"product_identification_helper": {
"model_numbers": [
"6GK5310-0FA10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X310 (6GK5310-0FA10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X310FE (6GK5310-0BA00-2AA3)",
"product_id": "62",
"product_identification_helper": {
"model_numbers": [
"6GK5310-0BA00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X310FE (6GK5310-0BA00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X310FE (6GK5310-0BA10-2AA3)",
"product_id": "63",
"product_identification_helper": {
"model_numbers": [
"6GK5310-0BA10-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X310FE (6GK5310-0BA10-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)",
"product_id": "64",
"product_identification_helper": {
"model_numbers": [
"6GK5320-1BD00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X320-1 FE (6GK5320-1BD00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)",
"product_id": "65",
"product_identification_helper": {
"model_numbers": [
"6GK5320-3BF00-2AA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X408-2 (6GK5408-2FD00-2AA2)",
"product_id": "66",
"product_identification_helper": {
"model_numbers": [
"6GK5408-2FD00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X408-2 (6GK5408-2FD00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)",
"product_id": "67",
"product_identification_helper": {
"model_numbers": [
"6GK5201-3BH00-2BD2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)",
"product_id": "68",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2BH00-2BD2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE XF204 (6GK5204-0BA00-2AF2)",
"product_id": "69",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2AF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204 (6GK5204-0BA00-2AF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE XF204-2 (6GK5204-2BC00-2AF2)",
"product_id": "70",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2BC00-2AF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204-2 (6GK5204-2BC00-2AF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)",
"product_id": "71",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2AA00-2BD2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SCALANCE XF204IRT (6GK5204-0BA00-2BF2)",
"product_id": "72",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2BF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204IRT (6GK5204-0BA00-2BF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE XF206-1 (6GK5206-1BC00-2AF2)",
"product_id": "73",
"product_identification_helper": {
"model_numbers": [
"6GK5206-1BC00-2AF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF206-1 (6GK5206-1BC00-2AF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2.6",
"product": {
"name": "SCALANCE XF208 (6GK5208-0BA00-2AF2)",
"product_id": "74",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA00-2AF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF208 (6GK5208-0BA00-2AF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)",
"product_id": "75",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-2ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)",
"product_id": "76",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-2ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)",
"product_id": "77",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-2JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)",
"product_id": "78",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-2JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)",
"product_id": "79",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-4ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)",
"product_id": "80",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-4ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)",
"product_id": "81",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-4JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)",
"product_id": "82",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-4JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)",
"product_id": "83",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-1ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)",
"product_id": "84",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-1ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)",
"product_id": "85",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-1JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)",
"product_id": "86",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-1JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)",
"product_id": "87",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-3ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)",
"product_id": "88",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-3ER2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)",
"product_id": "89",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG00-3JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)",
"product_id": "90",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4GG10-3JR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)",
"product_id": "91",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-1AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)",
"product_id": "92",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-1HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)",
"product_id": "93",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)",
"product_id": "94",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-3HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)",
"product_id": "95",
"product_identification_helper": {
"model_numbers": [
"6GK5324-4QG00-1CR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)",
"product_id": "96",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-1AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)",
"product_id": "97",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-1AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)",
"product_id": "98",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-1HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)",
"product_id": "99",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-1HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)",
"product_id": "100",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)",
"product_id": "101",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)",
"product_id": "102",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-3HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)",
"product_id": "103",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-3HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)",
"product_id": "104",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG00-1CR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)",
"product_id": "105",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0GG10-1CR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.5.2",
"product": {
"name": "SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)",
"product_id": "106",
"product_identification_helper": {
"model_numbers": [
"6AG1202-2BH00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)",
"product_id": "107",
"product_identification_helper": {
"model_numbers": [
"6AG1308-2FL10-4AA3"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-28895",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"31",
"30",
"29",
"28",
"27",
"26",
"25",
"24",
"32",
"33",
"41",
"40",
"39",
"38",
"37",
"36",
"35",
"34",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"100",
"101",
"102",
"103",
"96",
"97",
"98",
"99",
"104",
"105",
"87",
"88",
"89",
"90",
"83",
"84",
"85",
"86",
"79",
"80",
"81",
"82",
"75",
"76",
"77",
"78",
"93",
"94",
"91",
"92",
"95",
"106",
"107"
]
},
"remediations": [
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"31",
"30",
"29",
"28",
"27",
"26",
"25",
"24",
"32",
"33",
"41",
"40",
"39",
"38",
"37",
"36",
"35",
"34",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"100",
"101",
"102",
"103",
"96",
"97",
"98",
"99",
"104",
"105",
"87",
"88",
"89",
"90",
"83",
"84",
"85",
"86",
"79",
"80",
"81",
"82",
"75",
"76",
"77",
"78",
"93",
"94",
"91",
"92",
"95",
"107"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.2.6 or later version",
"product_ids": [
"8",
"9",
"10",
"11",
"12",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"69",
"70",
"73",
"74"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109811753/"
},
{
"category": "vendor_fix",
"details": "Update to V5.5.2 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"13",
"14",
"15",
"67",
"68",
"71",
"72",
"106"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817790/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"31",
"30",
"29",
"28",
"27",
"26",
"25",
"24",
"32",
"33",
"41",
"40",
"39",
"38",
"37",
"36",
"35",
"34",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"100",
"101",
"102",
"103",
"96",
"97",
"98",
"99",
"104",
"105",
"87",
"88",
"89",
"90",
"83",
"84",
"85",
"86",
"79",
"80",
"81",
"82",
"75",
"76",
"77",
"78",
"93",
"94",
"91",
"92",
"95",
"106",
"107"
]
}
],
"title": "CVE-2020-28895"
},
{
"cve": "CVE-2020-35198",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "The APIs cacheDmaMalloc()/cacheArchDmaMalloc()/mmap64() align the size of the requested buffer with the memory page size of the target platform. If the requested size is large enough to cause integer overflow by the alignment calculation, a valid pointer to a buffer that is smaller than the requested size is returned, opening the door to use for heap overflow attacks.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"31",
"30",
"29",
"28",
"27",
"26",
"25",
"24",
"32",
"33",
"41",
"40",
"39",
"38",
"37",
"36",
"35",
"34",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"100",
"101",
"102",
"103",
"96",
"97",
"98",
"99",
"104",
"105",
"87",
"88",
"89",
"90",
"83",
"84",
"85",
"86",
"79",
"80",
"81",
"82",
"75",
"76",
"77",
"78",
"93",
"94",
"91",
"92",
"95",
"106",
"107"
]
},
"remediations": [
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"31",
"30",
"29",
"28",
"27",
"26",
"25",
"24",
"32",
"33",
"41",
"40",
"39",
"38",
"37",
"36",
"35",
"34",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"100",
"101",
"102",
"103",
"96",
"97",
"98",
"99",
"104",
"105",
"87",
"88",
"89",
"90",
"83",
"84",
"85",
"86",
"79",
"80",
"81",
"82",
"75",
"76",
"77",
"78",
"93",
"94",
"91",
"92",
"95",
"107"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.2.6 or later version",
"product_ids": [
"8",
"9",
"10",
"11",
"12",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"69",
"70",
"73",
"74"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109811753/"
},
{
"category": "vendor_fix",
"details": "Update to V5.5.2 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"13",
"14",
"15",
"67",
"68",
"71",
"72",
"106"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817790/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"31",
"30",
"29",
"28",
"27",
"26",
"25",
"24",
"32",
"33",
"41",
"40",
"39",
"38",
"37",
"36",
"35",
"34",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"100",
"101",
"102",
"103",
"96",
"97",
"98",
"99",
"104",
"105",
"87",
"88",
"89",
"90",
"83",
"84",
"85",
"86",
"79",
"80",
"81",
"82",
"75",
"76",
"77",
"78",
"93",
"94",
"91",
"92",
"95",
"106",
"107"
]
}
],
"title": "CVE-2020-35198"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.