CVE-2020-3242
Vulnerability from cvelistv5
Published
2020-06-18 02:21
Modified
2024-11-15 16:59
Severity ?
EPSS score ?
Summary
A vulnerability in the REST API of Cisco UCS Director could allow an authenticated, remote attacker with administrative privileges to obtain confidential information from an affected device. The vulnerability exists because confidential information is returned as part of an API response. An attacker could exploit this vulnerability by sending a crafted request to the API. A successful exploit could allow the attacker to obtain the API key of another user, which would allow the attacker to impersonate the account of that user on the affected device. To exploit this vulnerability, the attacker must have administrative privileges on the device.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Cisco | Cisco Unified Computing System (Management Software) |
Version: n/a |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T07:30:58.119Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "20200617 Cisco UCS Director Information Disclosure Vulnerability", "tags": [ "vendor-advisory", "x_refsource_CISCO", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ucsd-info-disclosure-gSMU8EKT" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2020-3242", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-15T16:27:31.491474Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-15T16:59:45.138Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Cisco Unified Computing System (Management Software)", "vendor": "Cisco", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2020-06-17T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability in the REST API of Cisco UCS Director could allow an authenticated, remote attacker with administrative privileges to obtain confidential information from an affected device. The vulnerability exists because confidential information is returned as part of an API response. An attacker could exploit this vulnerability by sending a crafted request to the API. A successful exploit could allow the attacker to obtain the API key of another user, which would allow the attacker to impersonate the account of that user on the affected device. To exploit this vulnerability, the attacker must have administrative privileges on the device." } ], "exploits": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T02:21:18", "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "shortName": "cisco" }, "references": [ { "name": "20200617 Cisco UCS Director Information Disclosure Vulnerability", "tags": [ "vendor-advisory", "x_refsource_CISCO" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ucsd-info-disclosure-gSMU8EKT" } ], "source": { "advisory": "cisco-sa-ucsd-info-disclosure-gSMU8EKT", "defect": [ [ "CSCvs49968", "CSCvs49975" ] ], "discovery": "INTERNAL" }, "title": "Cisco UCS Director Information Disclosure Vulnerability", "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2020-06-17T16:00:00", "ID": "CVE-2020-3242", "STATE": "PUBLIC", "TITLE": "Cisco UCS Director Information Disclosure Vulnerability" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Cisco Unified Computing System (Management Software)", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability in the REST API of Cisco UCS Director could allow an authenticated, remote attacker with administrative privileges to obtain confidential information from an affected device. The vulnerability exists because confidential information is returned as part of an API response. An attacker could exploit this vulnerability by sending a crafted request to the API. A successful exploit could allow the attacker to obtain the API key of another user, which would allow the attacker to impersonate the account of that user on the affected device. To exploit this vulnerability, the attacker must have administrative privileges on the device." } ] }, "exploit": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "impact": { "cvss": { "baseScore": "4.9", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200" } ] } ] }, "references": { "reference_data": [ { "name": "20200617 Cisco UCS Director Information Disclosure Vulnerability", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ucsd-info-disclosure-gSMU8EKT" } ] }, "source": { "advisory": "cisco-sa-ucsd-info-disclosure-gSMU8EKT", "defect": [ [ "CSCvs49968", "CSCvs49975" ] ], "discovery": "INTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "assignerShortName": "cisco", "cveId": "CVE-2020-3242", "datePublished": "2020-06-18T02:21:18.752599Z", "dateReserved": "2019-12-12T00:00:00", "dateUpdated": "2024-11-15T16:59:45.138Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:cisco:ucs_director:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.7.4.0\", \"matchCriteriaId\": \"8999C8C0-A639-485D-BABF-EB7EE884BF8F\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability in the REST API of Cisco UCS Director could allow an authenticated, remote attacker with administrative privileges to obtain confidential information from an affected device. The vulnerability exists because confidential information is returned as part of an API response. An attacker could exploit this vulnerability by sending a crafted request to the API. A successful exploit could allow the attacker to obtain the API key of another user, which would allow the attacker to impersonate the account of that user on the affected device. To exploit this vulnerability, the attacker must have administrative privileges on the device.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad en la API REST de Cisco UCS Director, podr\\u00eda permitir a un atacante remoto autenticado con privilegios administrativos obtener informaci\\u00f3n confidencial de un dispositivo afectado. La vulnerabilidad se presenta porque la informaci\\u00f3n confidencial se devuelve como parte de una respuesta de la API. Un atacante podr\\u00eda explotar esta vulnerabilidad mediante el env\\u00edo de una petici\\u00f3n dise\\u00f1ada hacia la API. Una explotaci\\u00f3n con \\u00e9xito podr\\u00eda permitir al atacante obtener la clave de la API de otro usuario, lo que le permitir\\u00eda suplantar la cuenta de ese usuario en el dispositivo afectado. Para explotar esta vulnerabilidad, el atacante debe tener privilegios administrativos en el dispositivo\"}]", "id": "CVE-2020-3242", "lastModified": "2024-11-21T05:30:38.477", "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 4.9, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 3.6}], \"cvssMetricV30\": [{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 4.9, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:N/A:N\", \"baseScore\": 4.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}", "published": "2020-06-18T03:15:11.277", "references": "[{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ucsd-info-disclosure-gSMU8EKT\", \"source\": \"ykramarz@cisco.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ucsd-info-disclosure-gSMU8EKT\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", "sourceIdentifier": "ykramarz@cisco.com", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-200\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-200\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2020-3242\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2020-06-18T03:15:11.277\",\"lastModified\":\"2024-11-21T05:30:38.477\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the REST API of Cisco UCS Director could allow an authenticated, remote attacker with administrative privileges to obtain confidential information from an affected device. The vulnerability exists because confidential information is returned as part of an API response. An attacker could exploit this vulnerability by sending a crafted request to the API. A successful exploit could allow the attacker to obtain the API key of another user, which would allow the attacker to impersonate the account of that user on the affected device. To exploit this vulnerability, the attacker must have administrative privileges on the device.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la API REST de Cisco UCS Director, podr\u00eda permitir a un atacante remoto autenticado con privilegios administrativos obtener informaci\u00f3n confidencial de un dispositivo afectado. La vulnerabilidad se presenta porque la informaci\u00f3n confidencial se devuelve como parte de una respuesta de la API. Un atacante podr\u00eda explotar esta vulnerabilidad mediante el env\u00edo de una petici\u00f3n dise\u00f1ada hacia la API. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante obtener la clave de la API de otro usuario, lo que le permitir\u00eda suplantar la cuenta de ese usuario en el dispositivo afectado. Para explotar esta vulnerabilidad, el atacante debe tener privilegios administrativos en el dispositivo\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":4.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.2,\"impactScore\":3.6}],\"cvssMetricV30\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":4.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.2,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:ucs_director:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.7.4.0\",\"matchCriteriaId\":\"8999C8C0-A639-485D-BABF-EB7EE884BF8F\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ucsd-info-disclosure-gSMU8EKT\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ucsd-info-disclosure-gSMU8EKT\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ucsd-info-disclosure-gSMU8EKT\", \"name\": \"20200617 Cisco UCS Director Information Disclosure Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T07:30:58.119Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2020-3242\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-15T16:27:31.491474Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-15T16:28:04.658Z\"}}], \"cna\": {\"title\": \"Cisco UCS Director Information Disclosure Vulnerability\", \"source\": {\"defect\": [[\"CSCvs49968\", \"CSCvs49975\"]], \"advisory\": \"cisco-sa-ucsd-info-disclosure-gSMU8EKT\", \"discovery\": \"INTERNAL\"}, \"metrics\": [{\"cvssV3_0\": {\"scope\": \"UNCHANGED\", \"version\": \"3.0\", \"baseScore\": 4.9, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"Cisco\", \"product\": \"Cisco Unified Computing System (Management Software)\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"exploits\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"datePublic\": \"2020-06-17T00:00:00\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ucsd-info-disclosure-gSMU8EKT\", \"name\": \"20200617 Cisco UCS Director Information Disclosure Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in the REST API of Cisco UCS Director could allow an authenticated, remote attacker with administrative privileges to obtain confidential information from an affected device. The vulnerability exists because confidential information is returned as part of an API response. An attacker could exploit this vulnerability by sending a crafted request to the API. A successful exploit could allow the attacker to obtain the API key of another user, which would allow the attacker to impersonate the account of that user on the affected device. To exploit this vulnerability, the attacker must have administrative privileges on the device.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-200\", \"description\": \"CWE-200\"}]}], \"providerMetadata\": {\"orgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"shortName\": \"cisco\", \"dateUpdated\": \"2020-06-18T02:21:18\"}, \"x_legacyV4Record\": {\"impact\": {\"cvss\": {\"version\": \"3.0\", \"baseScore\": \"4.9\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\"}}, \"source\": {\"defect\": [[\"CSCvs49968\", \"CSCvs49975\"]], \"advisory\": \"cisco-sa-ucsd-info-disclosure-gSMU8EKT\", \"discovery\": \"INTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"Cisco Unified Computing System (Management Software)\"}]}, \"vendor_name\": \"Cisco\"}]}}, \"exploit\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ucsd-info-disclosure-gSMU8EKT\", \"name\": \"20200617 Cisco UCS Director Information Disclosure Vulnerability\", \"refsource\": \"CISCO\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A vulnerability in the REST API of Cisco UCS Director could allow an authenticated, remote attacker with administrative privileges to obtain confidential information from an affected device. The vulnerability exists because confidential information is returned as part of an API response. An attacker could exploit this vulnerability by sending a crafted request to the API. A successful exploit could allow the attacker to obtain the API key of another user, which would allow the attacker to impersonate the account of that user on the affected device. To exploit this vulnerability, the attacker must have administrative privileges on the device.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-200\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2020-3242\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Cisco UCS Director Information Disclosure Vulnerability\", \"ASSIGNER\": \"psirt@cisco.com\", \"DATE_PUBLIC\": \"2020-06-17T16:00:00\"}}}}", "cveMetadata": "{\"cveId\": \"CVE-2020-3242\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-15T16:59:45.138Z\", \"dateReserved\": \"2019-12-12T00:00:00\", \"assignerOrgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"datePublished\": \"2020-06-18T02:21:18.752599Z\", \"assignerShortName\": \"cisco\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.