CVE-2020-8478 (GCVE-0-2020-8478)
Vulnerability from cvelistv5 – Published: 2020-04-29 01:58 – Updated: 2024-08-04 10:03
VLAI?
Summary
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder.
Severity ?
5.3 (Medium)
CWE
- CWE-264 - Permissions, Privileges, and Access Controls
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ABB | OPC Server for AC 800M |
Affected:
all versions
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T10:03:44.802Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OPC Server for AC 800M",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "MMS Server for AC 800M",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "Base Software for SoftControl",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-264",
"description": "CWE-264 Permissions, Privileges, and Access Controls",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-29T01:58:54",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "ABB System 800xA Inter process communication vulnerability",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@ch.abb.com",
"ID": "CVE-2020-8478",
"STATE": "PUBLIC",
"TITLE": "ABB System 800xA Inter process communication vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "OPC Server for AC 800M",
"version": {
"version_data": [
{
"version_affected": "undefined",
"version_value": "all versions"
}
]
}
},
{
"product_name": "MMS Server for AC 800M",
"version": {
"version_data": [
{
"version_affected": "undefined",
"version_value": "all versions"
}
]
}
},
{
"product_name": "Base Software for SoftControl",
"version": {
"version_data": [
{
"version_affected": "undefined",
"version_value": "all versions"
}
]
}
}
]
},
"vendor_name": "ABB"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-264 Permissions, Privileges, and Access Controls"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
"refsource": "CONFIRM",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2020-8478",
"datePublished": "2020-04-29T01:58:54",
"dateReserved": "2020-01-30T00:00:00",
"dateUpdated": "2024-08-04T10:03:44.802Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:abb:mms_server:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"296927D5-AF68-488F-A606-818ACD253B75\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:abb:opc_server:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E9BF1B4E-225B-4A2C-A5EB-996A6CCA1F79\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:abb:ac800m:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"18F5825D-A99A-4109-A08F-114C7D6D3FC3\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:abb:base_software:*:*:*:*:*:softcontrol:*:*\", \"matchCriteriaId\": \"D30E09D7-4C4D-459F-95DC-3B9FA341E5A4\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder.\"}, {\"lang\": \"es\", \"value\": \"Una protecci\\u00f3n insuficiente de las funciones de comunicaci\\u00f3n entre procesos en los productos OPC Server para AC 800M, MMS Server para AC 800M y Base Software para SoftControl (todas las versiones publicadas) de ABB System 800xA, permite a un atacante autenticado en el sistema local inyectar datos, afectando la visualizaci\\u00f3n en l\\u00ednea de los datos del tiempo de ejecuci\\u00f3n que se muestran en Control Builder.\"}]",
"id": "CVE-2020-8478",
"lastModified": "2024-11-21T05:38:55.077",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@ch.abb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 3.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N\", \"baseScore\": 3.3, \"baseSeverity\": \"LOW\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 1.4}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:N/I:P/A:N\", \"baseScore\": 2.1, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 3.9, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2020-04-29T02:15:11.763",
"references": "[{\"url\": \"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\", \"source\": \"cybersecurity@ch.abb.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@ch.abb.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@ch.abb.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-264\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-74\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-8478\",\"sourceIdentifier\":\"cybersecurity@ch.abb.com\",\"published\":\"2020-04-29T02:15:11.763\",\"lastModified\":\"2024-11-21T05:38:55.077\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder.\"},{\"lang\":\"es\",\"value\":\"Una protecci\u00f3n insuficiente de las funciones de comunicaci\u00f3n entre procesos en los productos OPC Server para AC 800M, MMS Server para AC 800M y Base Software para SoftControl (todas las versiones publicadas) de ABB System 800xA, permite a un atacante autenticado en el sistema local inyectar datos, afectando la visualizaci\u00f3n en l\u00ednea de los datos del tiempo de ejecuci\u00f3n que se muestran en Control Builder.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":1.8,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N\",\"baseScore\":3.3,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:N/I:P/A:N\",\"baseScore\":2.1,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-264\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-74\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:mms_server:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"296927D5-AF68-488F-A606-818ACD253B75\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:opc_server:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E9BF1B4E-225B-4A2C-A5EB-996A6CCA1F79\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:abb:ac800m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18F5825D-A99A-4109-A08F-114C7D6D3FC3\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:base_software:*:*:*:*:*:softcontrol:*:*\",\"matchCriteriaId\":\"D30E09D7-4C4D-459F-95DC-3B9FA341E5A4\"}]}]}],\"references\":[{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"cybersecurity@ch.abb.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…