Cisco NX-OS Software Unauthenticated Arbitrary File Actions Vulnerability
Impacted products
CiscoCisco NX-OS Software
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T16:11:16.912Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20210224 Cisco NX-OS Software Unauthenticated Arbitrary File Actions Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-3000-9000-fileaction-QtLzDRy2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco NX-OS Software",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2021-02-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the implementation of an internal file management service for Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches in standalone NX-OS mode that are running Cisco NX-OS Software could allow an unauthenticated, remote attacker to create, delete, or overwrite arbitrary files with root privileges on the device. This vulnerability exists because TCP port 9075 is incorrectly configured to listen and respond to external connection requests. An attacker could exploit this vulnerability by sending crafted TCP packets to an IP address that is configured on a local interface on TCP port 9075. A successful exploit could allow the attacker to create, delete, or overwrite arbitrary files, including sensitive files that are related to the device configuration. For example, the attacker could add a user account without the device administrator knowing."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-552",
              "description": "CWE-552",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-24T19:30:41",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20210224 Cisco NX-OS Software Unauthenticated Arbitrary File Actions Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-3000-9000-fileaction-QtLzDRy2"
        }
      ],
      "source": {
        "advisory": "cisco-sa-3000-9000-fileaction-QtLzDRy2",
        "defect": [
          [
            "CSCvw89875"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco NX-OS Software Unauthenticated Arbitrary File Actions Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2021-02-24T16:00:00",
          "ID": "CVE-2021-1361",
          "STATE": "PUBLIC",
          "TITLE": "Cisco NX-OS Software Unauthenticated Arbitrary File Actions Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco NX-OS Software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the implementation of an internal file management service for Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches in standalone NX-OS mode that are running Cisco NX-OS Software could allow an unauthenticated, remote attacker to create, delete, or overwrite arbitrary files with root privileges on the device. This vulnerability exists because TCP port 9075 is incorrectly configured to listen and respond to external connection requests. An attacker could exploit this vulnerability by sending crafted TCP packets to an IP address that is configured on a local interface on TCP port 9075. A successful exploit could allow the attacker to create, delete, or overwrite arbitrary files, including sensitive files that are related to the device configuration. For example, the attacker could add a user account without the device administrator knowing."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "9.8",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-552"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20210224 Cisco NX-OS Software Unauthenticated Arbitrary File Actions Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-3000-9000-fileaction-QtLzDRy2"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-3000-9000-fileaction-QtLzDRy2",
          "defect": [
            [
              "CSCvw89875"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2021-1361",
    "datePublished": "2021-02-24T19:30:41.350830Z",
    "dateReserved": "2020-11-13T00:00:00",
    "dateUpdated": "2024-09-16T17:15:17.942Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-1361\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2021-02-24T20:15:13.287\",\"lastModified\":\"2023-11-07T03:28:05.767\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the implementation of an internal file management service for Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches in standalone NX-OS mode that are running Cisco NX-OS Software could allow an unauthenticated, remote attacker to create, delete, or overwrite arbitrary files with root privileges on the device. This vulnerability exists because TCP port 9075 is incorrectly configured to listen and respond to external connection requests. An attacker could exploit this vulnerability by sending crafted TCP packets to an IP address that is configured on a local interface on TCP port 9075. A successful exploit could allow the attacker to create, delete, or overwrite arbitrary files, including sensitive files that are related to the device configuration. For example, the attacker could add a user account without the device administrator knowing.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la implementaci\u00f3n de un servicio de administraci\u00f3n de archivos interno para Cisco Nexus 3000 Series Switches y Cisco Nexus 9000 Series Switches en modo NX-OS dedicado que ejecutan el software Cisco NX-OS podr\u00eda permitir a un atacante remoto no autenticado crear, eliminar o sobrescribir archivos arbitrarios con privilegios de root en el dispositivo.\u0026#xa0;Esta vulnerabilidad se presenta porque el puerto TCP 9075 est\u00e1 configurado incorrectamente para escuchar y responder a peticiones de conexi\u00f3n externa.\u0026#xa0;Un atacante podr\u00eda explotar esta vulnerabilidad mediante el env\u00edo de paquetes TCP dise\u00f1ados a una direcci\u00f3n IP configurada en una interfaz local en el puerto TCP 9075. Un ataque exitoso podr\u00eda permitir al atacante crear, eliminar o sobrescribir archivos arbitrarios, incluidos archivos confidenciales relacionados a la configuraci\u00f3n del dispositivo.\u0026#xa0;Por ejemplo, el atacante podr\u00eda agregar una cuenta de usuario sin que el administrador del dispositivo lo sepa\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:C/A:C\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":9.4},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":9.2,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-552\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:9.3\\\\(5\\\\):*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2A2F42DB-B22B-4880-BA73-D0E0295190DF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:nx-os:9.3\\\\(6\\\\):*:*:*:*:*:*:*\",\"matchCriteriaId\":\"85A8B2D7-BCF2-4B2E-8208-7D2FDF717C65\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_3000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"10FFC5E8-CC5A-4D31-A63A-19E72EC442AB\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_3100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"41C14CC9-C244-4B86-AEA6-C50BAD5DA9A6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_3100-z:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D14D4B4E-120E-4607-A4F1-447C7BF3052E\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_3100v:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"15702ACB-29F3-412D-8805-E107E0729E35\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_3200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"32A532C0-B0E3-484A-B356-88970E7D0248\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_3400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"43913A0E-50D5-47DD-94D8-DD3391633619\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_3500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A8E1073F-D374-4311-8F12-AD8C72FAA293\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_3600:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"97217080-455C-48E4-8CE1-6D5B9485864F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9000v:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0CD9C1F1-8582-4F67-A77D-97CBFECB88B8\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_92160yc-x:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4283E433-7F8C-4410-B565-471415445811\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_92300yc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F80AB6FB-32FD-43D7-A9F1-80FA47696210\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_92304qc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D5B2E4C1-2627-4B9D-8E92-4B483F647651\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_92348gc-x:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"557ED31C-C26A-4FAE-8B14-D06B49F7F08B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9236c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11411BFD-3F4D-4309-AB35-A3629A360FB0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9272q:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E663DE91-C86D-48DC-B771-FA72A8DF7A7C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93108tc-ex:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A90184B3-C82F-4CE5-B2AD-97D5E4690871\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93108tc-ex-24:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"40E40F42-632A-47DF-BE33-DC25B826310B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93108tc-fx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4AB89849-6DA4-4C9D-BC3F-EE0E41FD1901\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93108tc-fx-24:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C47F6BF9-2ADB-41A4-8D7D-8BB00141BB23\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93120tx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07DE6F63-2C7D-415B-8C34-01EC05C062F3\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93128tx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F423E45D-A6DD-4305-9C6A-EAB26293E53A\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9316d-gx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"102F91CD-DFB6-43D4-AE5B-DA157A696230\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180lc-ex:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E952A96A-0F48-4357-B7DD-1127D8827650\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-ex:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F70D81F1-8B12-4474-9060-B4934D8A3873\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-ex-24:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5394DE31-3863-4CA9-B7B1-E5227183100D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-fx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7349D69B-D8FA-4462-AA28-69DD18A652D9\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-fx-24:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FE4BB834-2C00-4384-A78E-AF3BCDDC58AF\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-fx3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B0D30D52-837F-4FDA-B8E5-A9066E9C6D2F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93180yc-fx3s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7CE49B45-F2E9-491D-9C29-1B46E9CE14E2\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93216tc-fx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B1CC5F78-E88B-4B82-9E3E-C73D3A49DE26\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93240yc-fx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"91231DC6-2773-4238-8C14-A346F213B5E5\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9332c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2DF88547-BAF4-47B0-9F60-80A30297FCEB\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9332pq:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"113772B6-E9D2-4094-9468-3F4E1A87D07D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93360yc-fx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C45A38D6-BED6-4FEF-AD87-A1E813695DE0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9336c-fx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F1FC2B1F-232E-4754-8076-CC82F3648730\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9336c-fx2-e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7CDD27C9-5EAF-4956-8AB7-740C84C9D4FC\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9336pq_aci_spine:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"785FD17C-F32E-4042-9DDE-A89B3AAE0334\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9348gc-fxp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"17C7E3DB-8E1A-47AD-B1C5-61747DC0CFB9\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_93600cd-gx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2CF467E2-4567-426E-8F48-39669E0F514C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9364c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"63842B25-8C32-4988-BBBD-61E9CB09B4F3\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9364c-gx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68EA1FEF-B6B6-49FE-A0A4-5387F76303F8\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9372px:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4364ADB9-8162-451D-806A-B98924E6B2CF\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9372px-e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B53BCB42-ED61-4FCF-8068-CB467631C63C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9372tx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"49E0371B-FDE2-473C-AA59-47E1269D050F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9372tx-e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"489D11EC-5A18-4F32-BC7C-AC1FCEC27222\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9396px:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1BC5293E-F2B4-46DC-85DA-167EA323FCFD\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9396tx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EA022E77-6557-4A33-9A3A-D028E2DB669A\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:nexus_9508:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DDC2F709-AFBE-48EA-A3A2-DA1134534FB6\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-3000-9000-fileaction-QtLzDRy2\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.