CVE-2021-20597
Vulnerability from cvelistv5
Published
2021-08-06 00:00
Modified
2024-08-03 17:45
Severity ?
EPSS score ?
Summary
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to login to the target unauthorizedly by sniffing network traffic and obtaining credentials when registering user information in the target or changing a password.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:45:44.727Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-009_en.pdf" }, { "tags": [ "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-250-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU; Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions \"26\" and prior" }, { "status": "affected", "version": "Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions \"11\" and prior" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eInsufficiently Protected Credentials vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions \"26\" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to login to the target unauthorizedly by sniffing network traffic and obtaining credentials when registering user information in the target or changing a password.\u003c/p\u003e" } ], "value": "Insufficiently Protected Credentials vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions \"26\" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to login to the target unauthorizedly by sniffing network traffic and obtaining credentials when registering user information in the target or changing a password." } ], "problemTypes": [ { "descriptions": [ { "description": "Insufficiently Protected Credentials", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-24T07:50:28.720Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-009_en.pdf" }, { "url": "https://jvn.jp/vu/JVNVU98578731/index.html" }, { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-250-01" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2021-20597", "datePublished": "2021-08-06T00:00:00", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:45:44.727Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-20597\",\"sourceIdentifier\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"published\":\"2021-08-06T17:15:07.140\",\"lastModified\":\"2024-05-24T08:15:08.760\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Insufficiently Protected Credentials vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions \\\"26\\\" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions \\\"11\\\" and prior allows a remote unauthenticated attacker to login to the target unauthorizedly by sniffing network traffic and obtaining credentials when registering user information in the target or changing a password.\"},{\"lang\":\"es\",\"value\":\"La vulnerabilidad de credenciales insuficientemente protegidas en los m\u00f3dulos de CPU de seguridad de la serie MELSEC iQ-R de Mitsubishi Electric R08/16/32/120SFCPU, versiones de firmware \\\"26\\\" y anteriores, y en los m\u00f3dulos de CPU de proceso SIL2 de la serie MELSEC iQ-R de Mitsubishi Electric R08/16/32/120PSFCPU, todas las versiones, permite que un atacante remoto no autenticado inicie sesi\u00f3n en el objetivo de forma no autorizada mediante el olfateo del tr\u00e1fico de red y la obtenci\u00f3n de credenciales al registrar informaci\u00f3n de usuario en el objetivo o al cambiar una contrase\u00f1a\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.4},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-522\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:r08sfcpu_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"66D3AC7B-50E0-47D5-B0D1-07329D724EFE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:r08sfcpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B185323A-C9E3-48A0-AD28-DA7AC7846E18\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:r16sfcpu_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AA81D5C7-46C8-4F0E-9550-D240DC0366F3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:r16sfcpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C4BBE066-33C4-4410-85D3-4B77B3773330\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:r32sfcpu_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7FB53D61-6C69-4A4A-92B1-C10D0B8F0EC9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:r32sfcpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F6304BE-DAEE-49AB-B0B1-CEE6878CBECE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:r120sfcpu_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8218130C-4E7D-4FB9-976B-2351977C82D4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:r120sfcpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"515BDC46-5A1C-4A94-816A-B4751BB1B58D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:r08psfcpu_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5A63D33D-302A-428C-986F-FC3F83CE9C86\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:r08psfcpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EA37F2FC-8F75-4FEA-882D-87AD5CC1558E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:r16psfcpu_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FFB42739-E503-44B2-A020-0DB2B8791A81\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:r16psfcpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"17AD5875-B7D7-498B-9484-23049753133E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:r32psfcpu_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3B1F532B-8EAF-4E66-9AF5-5EEFF5A0BC23\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:r32psfcpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0EC2594C-6067-40BA-B8B2-AEC9B9C7922F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:r120psfcpu_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B2C03EA2-34BF-4F86-A19C-2818788E092B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:r120psfcpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CA3FB3E1-D7D3-424B-A207-D3C6F4365D12\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/vu/JVNVU98578731/index.html\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-21-250-01\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\"},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-009_en.pdf\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.