CVE-2021-20990 (GCVE-0-2021-20990)
Vulnerability from cvelistv5 – Published: 2021-04-19 14:05 – Updated: 2024-09-16 16:42
VLAI
EPSS
VEX
Title
Fibaro Home Center Unauthenticated access to shutdown, reboot and reboot to recovery mode
Summary
In Fibaro Home Center 2 and Lite devices with firmware version 4.600 and older an internal management service is accessible on port 8000 and some API endpoints could be accessed without authentication to trigger a shutdown, a reboot or a reboot into recovery mode.
Severity
7.5 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.iot-inspector.com/blog/advisory-fibar… | x_refsource_CONFIRM |
| http://seclists.org/fulldisclosure/2021/Apr/27 | mailing-listx_refsource_FULLDISC |
| http://packetstormsecurity.com/files/162243/Fibar… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Fibar Group S.A | Fibaro Home Center |
Affected:
Home Center 2 , ≤ 4.600
(custom)
Affected: Home Center Lite , ≤ 4.600 (custom) |
guessed |
Date Public
2021-04-15 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.099Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"
},
{
"name": "20210419 [CVE-2021-20989, CVE-2021-20990, CVE-2021-20991, CVE-2021-20992] Multiple vulnerabilities in Fibaro Home Center",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2021/Apr/27"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Fibaro Home Center",
"vendor": "Fibar Group S.A",
"versions": [
{
"lessThanOrEqual": "4.600",
"status": "affected",
"version": "Home Center 2",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.600",
"status": "affected",
"version": "Home Center Lite",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Marton Illes IoT Inspector Research Lab https://www.iot-inspector.com"
}
],
"datePublic": "2021-04-15T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "In Fibaro Home Center 2 and Lite devices with firmware version 4.600 and older an internal management service is accessible on port 8000 and some API endpoints could be accessed without authentication to trigger a shutdown, a reboot or a reboot into recovery mode."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-30T09:15:17.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"
},
{
"name": "20210419 [CVE-2021-20989, CVE-2021-20990, CVE-2021-20991, CVE-2021-20992] Multiple vulnerabilities in Fibaro Home Center",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2021/Apr/27"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Fibaro Home Center Unauthenticated access to shutdown, reboot and reboot to recovery mode",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-04-15T10:00:00.000Z",
"ID": "CVE-2021-20990",
"STATE": "PUBLIC",
"TITLE": "Fibaro Home Center Unauthenticated access to shutdown, reboot and reboot to recovery mode"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Fibaro Home Center",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "Home Center 2",
"version_value": "4.600"
},
{
"version_affected": "\u003c=",
"version_name": "Home Center Lite",
"version_value": "4.600"
}
]
}
}
]
},
"vendor_name": "Fibar Group S.A"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Marton Illes IoT Inspector Research Lab https://www.iot-inspector.com"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Fibaro Home Center 2 and Lite devices with firmware version 4.600 and older an internal management service is accessible on port 8000 and some API endpoints could be accessed without authentication to trigger a shutdown, a reboot or a reboot into recovery mode."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/",
"refsource": "CONFIRM",
"url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"
},
{
"name": "20210419 [CVE-2021-20989, CVE-2021-20990, CVE-2021-20991, CVE-2021-20992] Multiple vulnerabilities in Fibaro Home Center",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2021/Apr/27"
},
{
"name": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"
}
]
},
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-20990",
"datePublished": "2021-04-19T14:05:02.510Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2024-09-16T16:42:28.116Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-20990",
"date": "2026-10-27",
"epss": "0.03429",
"percentile": "0.88869"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fibaro:home_center_2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "867FAF63-0352-4AC8-AB9D-1FDEC2E942D4",
"versionEndIncluding": "4.600",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fibaro:home_center_2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8021D17B-DD82-46D0-AE92-372649467F1F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fibaro:home_center_lite_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A06A908C-D871-46DA-AC42-63FF1518A558",
"versionEndIncluding": "4.600",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fibaro:home_center_lite:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6A19AFCC-B670-450C-8B64-7770C86B4692",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"descriptions": [
{
"lang": "en",
"value": "In Fibaro Home Center 2 and Lite devices with firmware version 4.600 and older an internal management service is accessible on port 8000 and some API endpoints could be accessed without authentication to trigger a shutdown, a reboot or a reboot into recovery mode."
},
{
"lang": "es",
"value": "En los dispositivos Fibaro Home Center versi\u00f3n 2 y Lite con versiones de firmware 4.600 y anteriores, un servicio de administraci\u00f3n interno es accesible en el puerto 8000 y algunos endpoints de la API pueden ser accedidos sin autenticaci\u00f3n para desencadenar un apagado, un reinicio o un reinicio en modo de recuperaci\u00f3n"
}
],
"id": "CVE-2021-20990",
"lastModified": "2024-11-21T05:47:20.700",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
},
"published": "2021-04-19T14:15:11.710",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"
},
{
"source": "info@cert.vde.com",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "http://seclists.org/fulldisclosure/2021/Apr/27"
},
{
"source": "info@cert.vde.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "http://seclists.org/fulldisclosure/2021/Apr/27"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "info@cert.vde.com",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fibaro:home_center_2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "867FAF63-0352-4AC8-AB9D-1FDEC2E942D4",
"versionEndIncluding": "4.600",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fibaro:home_center_2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8021D17B-DD82-46D0-AE92-372649467F1F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fibaro:home_center_lite_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A06A908C-D871-46DA-AC42-63FF1518A558",
"versionEndIncluding": "4.600",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fibaro:home_center_lite:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6A19AFCC-B670-450C-8B64-7770C86B4692",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In Fibaro Home Center 2 and Lite devices with firmware version 4.600 and older an internal management service is accessible on port 8000 and some API endpoints could be accessed without authentication to trigger a shutdown, a reboot or a reboot into recovery mode."
},
{
"lang": "es",
"value": "En los dispositivos Fibaro Home Center versi\u00f3n 2 y Lite con versiones de firmware 4.600 y anteriores, un servicio de administraci\u00f3n interno es accesible en el puerto 8000 y algunos endpoints de la API pueden ser accedidos sin autenticaci\u00f3n para desencadenar un apagado, un reinicio o un reinicio en modo de recuperaci\u00f3n"
}
],
"id": "CVE-2021-20990",
"lastModified": "2024-11-21T05:47:20.700",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
},
"published": "2021-04-19T14:15:11.710",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"
},
{
"source": "info@cert.vde.com",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "http://seclists.org/fulldisclosure/2021/Apr/27"
},
{
"source": "info@cert.vde.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "http://seclists.org/fulldisclosure/2021/Apr/27"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "info@cert.vde.com",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-03-27T14:59:15+00:00",
"cve": "CVE-2021-20990",
"id": "CVE-2021-20990",
"initial_release_date": "2021-04-15T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Fibaro Home Center Unauthenticated access to shutdown, reboot and reboot to recovery mode",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-20990.json",
"version": "3"
}
}
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.