CVE-2021-21555
Vulnerability from cvelistv5
Published
2021-06-14 19:10
Modified
2024-09-16 22:29
Severity ?
EPSS score ?
Summary
Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS contain a heap-based buffer overflow vulnerability in systems with NVDIMM-N installed. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of Service, arbitrary code execution, or information disclosure in UEFI or BIOS Preboot Environment.
References
▼ | URL | Tags | |
---|---|---|---|
security_alert@emc.com | https://www.dell.com/support/kbdoc/000187958 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dell.com/support/kbdoc/000187958 | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Dell | PowerEdge BIOS Intel 15G |
Version: unspecified < 2.11.2 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:16:22.970Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/000187958" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "PowerEdge BIOS Intel 15G", "vendor": "Dell", "versions": [ { "lessThan": "2.11.2", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2021-06-08T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS contain a heap-based buffer overflow vulnerability in systems with NVDIMM-N installed. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of Service, arbitrary code execution, or information disclosure in UEFI or BIOS Preboot Environment." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-06-14T19:10:15", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/kbdoc/000187958" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2021-06-08", "ID": "CVE-2021-21555", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "PowerEdge BIOS Intel 15G", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "2.11.2" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS contain a heap-based buffer overflow vulnerability in systems with NVDIMM-N installed. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of Service, arbitrary code execution, or information disclosure in UEFI or BIOS Preboot Environment." } ] }, "impact": { "cvss": { "baseScore": 6.1, "baseSeverity": "Medium", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-122: Heap-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/kbdoc/000187958", "refsource": "MISC", "url": "https://www.dell.com/support/kbdoc/000187958" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2021-21555", "datePublished": "2021-06-14T19:10:15.341153Z", "dateReserved": "2021-01-04T00:00:00", "dateUpdated": "2024-09-16T22:29:57.065Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:poweredge_r640_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.11.2\", \"matchCriteriaId\": \"C6D7153C-E15D-4041-B45F-207DEB0B13AE\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:poweredge_r640:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"81416C16-D7FA-4165-BB0E-6458A4EA5AEE\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:poweredge_r740_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.11.2\", \"matchCriteriaId\": \"4502AE6D-BA6B-46AA-A214-99143272BA70\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:poweredge_r740:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DE562535-3D9B-4A82-AC0D-6A2225E63E8D\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:poweredge_r740xd_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.11.2\", \"matchCriteriaId\": \"3798FD8A-8A44-49F3-83E0-FD3D541DBCC2\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:poweredge_r740xd:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"868ECD3F-77CD-4F5D-86E5-61689E4C5BA0\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:poweredge_r940_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.11.2\", \"matchCriteriaId\": \"CD596C2D-BA27-4ED0-BCF4-F9792AD3E358\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:poweredge_r940:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B581E1DE-4E94-49E5-B5CF-2A94B2570708\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:poweredge_r840_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.11.2\", \"matchCriteriaId\": \"9E8EDAF7-4C73-49F5-840A-A3E3DD4ED72D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:poweredge_r840:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E058B9C6-CD1C-42F5-8781-05450254E9E5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:poweredge_r940xa_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.11.2\", \"matchCriteriaId\": \"F96E70D7-502B-42B9-8C50-30B685CC0E9E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:poweredge_r940xa:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3D143853-3D62-4AD7-B899-F726036A34D2\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:poweredge_t640_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.11.2\", \"matchCriteriaId\": \"E2AE262A-7389-4CB1-8A76-7B723563BEF6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:poweredge_t640:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1DEC0235-DDA1-4EE4-B3F8-512F1B29AFC6\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:poweredge_mx740c_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.11.2\", \"matchCriteriaId\": \"6552B1DC-BA56-42BC-AC35-374C764F256E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:poweredge_mx740c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"757039D5-60B9-40B0-B719-38E27409BDDE\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:poweredge_mx840c_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.11.2\", \"matchCriteriaId\": \"24D97615-28EC-4484-8E1E-BFB8EABE3284\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:poweredge_mx840c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E4305D0F-CB59-49D5-8D21-8ECC3342C36C\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS contain a heap-based buffer overflow vulnerability in systems with NVDIMM-N installed. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of Service, arbitrary code execution, or information disclosure in UEFI or BIOS Preboot Environment.\"}, {\"lang\": \"es\", \"value\": \"Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, y T640 Server BIOS contienen una vulnerabilidad de desbordamiento del b\\u00fafer en la regi\\u00f3n stack de la memoria en sistemas con NVDIMM-N instalados. Un usuario local malicioso con privilegios elevados puede explotar potencialmente esta vulnerabilidad, conllevando a una denegaci\\u00f3n de servicio, una ejecuci\\u00f3n de c\\u00f3digo arbitrario o una divulgaci\\u00f3n de informaci\\u00f3n en UEFI o BIOS Preboot Environment\"}]", "id": "CVE-2021-21555", "lastModified": "2024-11-21T05:48:35.320", "metrics": "{\"cvssMetricV31\": [{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:L\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 0.6, \"impactScore\": 5.5}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 6.7, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 7.2, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 3.9, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}", "published": "2021-06-14T19:15:08.273", "references": "[{\"url\": \"https://www.dell.com/support/kbdoc/000187958\", \"source\": \"security_alert@emc.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.dell.com/support/kbdoc/000187958\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", "sourceIdentifier": "security_alert@emc.com", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-122\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2021-21555\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2021-06-14T19:15:08.273\",\"lastModified\":\"2024-11-21T05:48:35.320\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS contain a heap-based buffer overflow vulnerability in systems with NVDIMM-N installed. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of Service, arbitrary code execution, or information disclosure in UEFI or BIOS Preboot Environment.\"},{\"lang\":\"es\",\"value\":\"Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, y T640 Server BIOS contienen una vulnerabilidad de desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria en sistemas con NVDIMM-N instalados. Un usuario local malicioso con privilegios elevados puede explotar potencialmente esta vulnerabilidad, conllevando a una denegaci\u00f3n de servicio, una ejecuci\u00f3n de c\u00f3digo arbitrario o una divulgaci\u00f3n de informaci\u00f3n en UEFI o BIOS Preboot Environment\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:L\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":0.6,\"impactScore\":5.5},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-122\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:poweredge_r640_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.11.2\",\"matchCriteriaId\":\"C6D7153C-E15D-4041-B45F-207DEB0B13AE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:poweredge_r640:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"81416C16-D7FA-4165-BB0E-6458A4EA5AEE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:poweredge_r740_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.11.2\",\"matchCriteriaId\":\"4502AE6D-BA6B-46AA-A214-99143272BA70\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:poweredge_r740:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DE562535-3D9B-4A82-AC0D-6A2225E63E8D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:poweredge_r740xd_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.11.2\",\"matchCriteriaId\":\"3798FD8A-8A44-49F3-83E0-FD3D541DBCC2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:poweredge_r740xd:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"868ECD3F-77CD-4F5D-86E5-61689E4C5BA0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:poweredge_r940_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.11.2\",\"matchCriteriaId\":\"CD596C2D-BA27-4ED0-BCF4-F9792AD3E358\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:poweredge_r940:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B581E1DE-4E94-49E5-B5CF-2A94B2570708\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:poweredge_r840_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.11.2\",\"matchCriteriaId\":\"9E8EDAF7-4C73-49F5-840A-A3E3DD4ED72D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:poweredge_r840:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E058B9C6-CD1C-42F5-8781-05450254E9E5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:poweredge_r940xa_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.11.2\",\"matchCriteriaId\":\"F96E70D7-502B-42B9-8C50-30B685CC0E9E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:poweredge_r940xa:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3D143853-3D62-4AD7-B899-F726036A34D2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:poweredge_t640_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.11.2\",\"matchCriteriaId\":\"E2AE262A-7389-4CB1-8A76-7B723563BEF6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:poweredge_t640:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1DEC0235-DDA1-4EE4-B3F8-512F1B29AFC6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:poweredge_mx740c_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.11.2\",\"matchCriteriaId\":\"6552B1DC-BA56-42BC-AC35-374C764F256E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:poweredge_mx740c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"757039D5-60B9-40B0-B719-38E27409BDDE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:poweredge_mx840c_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.11.2\",\"matchCriteriaId\":\"24D97615-28EC-4484-8E1E-BFB8EABE3284\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:poweredge_mx840c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E4305D0F-CB59-49D5-8D21-8ECC3342C36C\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/000187958\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/000187958\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.