CVE-2021-22716
Vulnerability from cvelistv5
Published
2021-04-13 18:31
Modified
2024-09-16 22:02
Summary
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:51:06.795Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "C-Bus Toolkit",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "1.15.9",
              "status": "affected",
              "version": "V",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-11-08T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-18T00:00:00",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf"
        },
        {
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2021-22716",
    "datePublished": "2021-04-13T18:31:18.018125Z",
    "dateReserved": "2021-01-06T00:00:00",
    "dateUpdated": "2024-09-16T22:02:57.408Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-22716\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2021-04-13T19:15:14.210\",\"lastModified\":\"2022-11-18T23:15:16.227\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)\"},{\"lang\":\"es\",\"value\":\"Una  CWE-732: Asignaci\u00f3n incorrecta de permisos para recursos cr\u00edticos que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo cuando un usuario sin privilegios modifica un archivo. Producto afectado: C-Bus Toolkit (V1.15.9 y anteriores)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":4.6},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.15.7\",\"matchCriteriaId\":\"F0CC2C60-78DD-4959-B70F-CF0A3073FC56\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf\",\"source\":\"cybersecurity@se.com\"},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01\",\"source\":\"cybersecurity@se.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.