Summary
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Schneider Electric | C-Bus Toolkit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:06.795Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf" }, { "tags": [ "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "C-Bus Toolkit", "vendor": "Schneider Electric", "versions": [ { "lessThan": "1.15.9", "status": "affected", "version": "V", "versionType": "custom" } ] } ], "datePublic": "2022-11-08T00:00:00", "descriptions": [ { "lang": "en", "value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732 Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-11-18T00:00:00", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf" }, { "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22716", "datePublished": "2021-04-13T18:31:18.018125Z", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-09-16T22:02:57.408Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-22716\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2021-04-13T19:15:14.210\",\"lastModified\":\"2022-11-18T23:15:16.227\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)\"},{\"lang\":\"es\",\"value\":\"Una CWE-732: Asignaci\u00f3n incorrecta de permisos para recursos cr\u00edticos que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo cuando un usuario sin privilegios modifica un archivo. Producto afectado: C-Bus Toolkit (V1.15.9 y anteriores)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":4.6},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.15.7\",\"matchCriteriaId\":\"F0CC2C60-78DD-4959-B70F-CF0A3073FC56\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf\",\"source\":\"cybersecurity@se.com\"},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01\",\"source\":\"cybersecurity@se.com\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.