CVE-2021-40336
Vulnerability from cvelistv5
Published
2022-07-25 14:34
Modified
2024-09-17 02:58
Summary
HTTP Response Splitting in Hitachi Energy’s MSM Product
Impacted products
Hitachi EnergyMSM
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:27:31.879Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000085\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MSM",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "V2.2",
              "status": "affected",
              "version": "v2.2",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-07-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability exists in the http web interface where the web interface does not validate data in an HTTP header. This causes a possible HTTP response splitting, which if exploited could lead an attacker to channel down harmful code into the user\u2019s web browser, such as to steal the session cookies. Thus, an attacker who successfully makes an MSM user who has already established a session to MSM web interface clicks a forged link to the MSM web interface, e.g., the link is sent per E-Mail, could trick the user into downloading malicious software onto his computer. This issue affects: Hitachi Energy MSM V2.2 and prior versions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-113",
              "description": "CWE-113 Improper Neutralization of CRLF Sequences in HTTP Headers (\u0027HTTP Response Splitting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-25T14:34:20",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000085\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "HTTP Response Splitting in Hitachi Energy\u2019s MSM Product",
      "workarounds": [
        {
          "lang": "en",
          "value": "Apply mitigation strategy as described in Mitigation Factors Section in the advisory."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@hitachienergy.com",
          "DATE_PUBLIC": "2022-07-12T14:30:00.000Z",
          "ID": "CVE-2021-40336",
          "STATE": "PUBLIC",
          "TITLE": "HTTP Response Splitting in Hitachi Energy\u2019s MSM Product"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MSM",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "v2.2",
                            "version_value": "V2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hitachi Energy"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability exists in the http web interface where the web interface does not validate data in an HTTP header. This causes a possible HTTP response splitting, which if exploited could lead an attacker to channel down harmful code into the user\u2019s web browser, such as to steal the session cookies. Thus, an attacker who successfully makes an MSM user who has already established a session to MSM web interface clicks a forged link to the MSM web interface, e.g., the link is sent per E-Mail, could trick the user into downloading malicious software onto his computer. This issue affects: Hitachi Energy MSM V2.2 and prior versions."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-113 Improper Neutralization of CRLF Sequences in HTTP Headers (\u0027HTTP Response Splitting\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000085\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000085\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "source": {
          "discovery": "INTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Apply mitigation strategy as described in Mitigation Factors Section in the advisory."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2021-40336",
    "datePublished": "2022-07-25T14:34:20.375500Z",
    "dateReserved": "2021-08-31T00:00:00",
    "dateUpdated": "2024-09-17T02:58:14.314Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-40336\",\"sourceIdentifier\":\"cybersecurity@hitachienergy.com\",\"published\":\"2022-07-25T15:15:09.247\",\"lastModified\":\"2023-06-26T17:49:15.913\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability exists in the http web interface where the web interface does not validate data in an HTTP header. This causes a possible HTTP response splitting, which if exploited could lead an attacker to channel down harmful code into the user\u2019s web browser, such as to steal the session cookies. Thus, an attacker who successfully makes an MSM user who has already established a session to MSM web interface clicks a forged link to the MSM web interface, e.g., the link is sent per E-Mail, could trick the user into downloading malicious software onto his computer. This issue affects: Hitachi Energy MSM V2.2 and prior versions.\"},{\"lang\":\"es\",\"value\":\"Se presenta una vulnerabilidad en la interfaz web http en la que \u00e9sta no comprueba los datos de un encabezado HTTP. Esto causa una posible divisi\u00f3n de la respuesta HTTP, que si es explotada podr\u00eda conllevar a un atacante a canalizar c\u00f3digo da\u00f1ino en el navegador web del usuario, como por ejemplo robar las cookies de sesi\u00f3n. As\u00ed, un atacante que consiga que un usuario de MSM que ya ha establecido una sesi\u00f3n en la interfaz web de MSM haga clic en un enlace falsificado a la interfaz web de MSM, por ejemplo, el enlace es enviado por correo electr\u00f3nico, podr\u00eda enga\u00f1ar al usuario para que descargue software malicioso en su ordenador. Este problema afecta a: Hitachi Energy MSM versiones V2.2 y versiones anteriores\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\",\"baseScore\":5.0,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.6,\"impactScore\":3.4}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-74\"}]},{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-113\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:modular_switchgear_monitoring_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.2.0\",\"matchCriteriaId\":\"105E197F-5BCD-445C-B20B-294619685EC5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hitachienergy:modular_switchgear_monitoring:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6CBD92D1-045F-44D8-99B1-12C28B0271F9\"}]}]}],\"references\":[{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000085\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"cybersecurity@hitachienergy.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.