Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2021-43336
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf | Third Party Advisory | |
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf | Third Party Advisory | |
cve@mitre.org | https://www.opendesign.com/security-advisories | Vendor Advisory | |
cve@mitre.org | https://www.zerodayinitiative.com/advisories/ZDI-22-334/ | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.opendesign.com/security-advisories | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-22-334/ | Third Party Advisory, VDB Entry |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T03:55:28.546Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.opendesign.com/security-advisories" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf" }, { "tags": [ "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-334/" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-14T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.opendesign.com/security-advisories" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf" }, { "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-334/" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-43336", "datePublished": "2021-11-14T00:00:00", "dateReserved": "2021-11-03T00:00:00", "dateUpdated": "2024-08-04T03:55:28.546Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-43336\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-11-14T21:15:08.263\",\"lastModified\":\"2024-11-21T06:29:06.483\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se presenta una vulnerabilidad de escritura fuera de l\u00edmites cuando es le\u00eddo un archivo DXF usando Open Design Alliance Drawings SDK versiones anteriores a 2022.11. El problema espec\u00edfico es presentado dentro del an\u00e1lisis de los archivos DXF. Los datos dise\u00f1ados en un archivo DXF (un n\u00famero no v\u00e1lido de propiedades) pueden desencadenar una operaci\u00f3n de escritura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opendesign:drawings_software_development_kit:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.11\",\"matchCriteriaId\":\"2517E46B-54DB-49E1-88DB-905365792054\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C51D6378-471B-45B2-9666-1AA4FB509E7A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2022:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"61866294-2060-457C-9CBE-8AEAF03973F6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.4.0\",\"versionEndExcluding\":\"12.4.0.13\",\"matchCriteriaId\":\"BAAA3630-3C59-43E8-9793-B3DD3276B58C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.0\",\"versionEndExcluding\":\"13.3.0.1\",\"matchCriteriaId\":\"CFBB1E39-FCCF-4F33-ADB4-74849D0E65CB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:13.1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A817DDD3-A448-46FE-8232-21E307A677F9\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.opendesign.com/security-advisories\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-22-334/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.opendesign.com/security-advisories\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-22-334/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}" } }
ICSA-23-047-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Michael Heinzl" ], "summary": "reporting these vulnerabilities to Siemens" }, { "organization": "Trend Micro Zero Day Initiative", "summary": "reporting these vulnerabilities to Siemens" }, { "organization": "Open Design Alliance", "summary": "reporting these vulnerabilities to Siemens" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "If malicious cyber actor tricks a user into opening a malicious file with the affected applications, it could allow the cyber actor to crash the application, extract data, or arbitrarily execute code.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "Do not click web links or open attachments in unsolicited email messages.", "title": "Recommended Practices" }, { "category": "general", "text": "Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.", "title": "Recommended Practices" }, { "category": "general", "text": "Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.", "title": "Recommended Practices" }, { "category": "general", "text": "if no known exploits exist, the last sentence of the Mitigation section should include the following.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely. These vulnerabilities have low attack complexity.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-491245.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-047-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-047-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-047-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-047-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/Recommended-Practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://cisa.gov/ics" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" }, { "category": "external", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "category": "external", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-491245.txt" } ], "title": "Siemens Solid Edge", "tracking": { "current_release_date": "2023-02-20T22:10:45.298464Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-047-01", "initial_release_date": "2023-02-20T22:10:45.298464Z", "revision_history": [ { "date": "2023-02-20T22:10:45.298464Z", "legacy_version": "1", "number": "1", "summary": "CSAF Creation Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Solid Edge SE2022", "product_id": "CSAFPID-0001" } }, { "category": "product_version_range", "name": "\u003c V222.0MP12", "product": { "name": "Solid Edge SE2022", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Solid Edge SE2022" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V223.0Update2", "product": { "name": "Solid Edge SE2023", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Solid Edge SE2023" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13408, ZDI-CAN-19072)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32936" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32936" }, { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service (crash). (ZDI-CAN-13378, ZDI-CAN-19073)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32938" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32938" }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DWG files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-19074, ZDI-CAN-13410)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32948" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32948" }, { "cve": "CVE-2021-43336", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15107, ZDI-CAN-19080, ZDI-CAN-19075)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-43336" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-43336" }, { "cve": "CVE-2021-43391", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19082)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-43391" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-43391" }, { "cve": "CVE-2022-46345", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46345" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46345" }, { "cve": "CVE-2022-46346", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46346" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46346" }, { "cve": "CVE-2022-46347", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46347" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46347" }, { "cve": "CVE-2022-46348", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46348" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46348" }, { "cve": "CVE-2022-46349", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46349" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46349" }, { "cve": "CVE-2023-22295", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19448)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22295" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22295" }, { "cve": "CVE-2023-22321", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19501)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22321" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22321" }, { "cve": "CVE-2023-22354", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products \r\n contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19424)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22354" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22354" }, { "cve": "CVE-2023-22669", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19104)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22669" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22669" }, { "cve": "CVE-2023-22670", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19382)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22670" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22670" }, { "cve": "CVE-2023-22846", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19473)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22846" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22846" }, { "cve": "CVE-2023-23579", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This could allow an attacker to to execute code in the context of the current process. (ZDI-CAN-19423)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-23579" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-23579" }, { "cve": "CVE-2023-24549", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24549" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24549" }, { "cve": "CVE-2023-24550", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to heap-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24550" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24550" }, { "cve": "CVE-2023-24551", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to heap-based buffer underflow while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24551" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24551" }, { "cve": "CVE-2023-24552", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24552" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24552" }, { "cve": "CVE-2023-24553", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24553" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24553" }, { "cve": "CVE-2023-24554", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24554" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24554" }, { "cve": "CVE-2023-24555", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24555" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24555" }, { "cve": "CVE-2023-24556", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24556" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24556" }, { "cve": "CVE-2023-24557", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24557" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24557" }, { "cve": "CVE-2023-24558", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24558" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24558" }, { "cve": "CVE-2023-24559", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24559" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24559" }, { "cve": "CVE-2023-24560", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24560" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24560" }, { "cve": "CVE-2023-24561", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24561" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24561" }, { "cve": "CVE-2023-24562", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24562" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24562" }, { "cve": "CVE-2023-24563", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24563" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24563" }, { "cve": "CVE-2023-24564", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "The affected application contains a memory corruption vulnerability while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19069)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24564" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24564" }, { "cve": "CVE-2023-24565", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24565" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24565" }, { "cve": "CVE-2023-24566", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24566" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24566" }, { "cve": "CVE-2023-24581", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted STP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19425)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24581" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24581" }, { "cve": "CVE-2023-25140", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-25140" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2023-25140" } ] }
icsa-23-047-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Michael Heinzl" ], "summary": "reporting these vulnerabilities to Siemens" }, { "organization": "Trend Micro Zero Day Initiative", "summary": "reporting these vulnerabilities to Siemens" }, { "organization": "Open Design Alliance", "summary": "reporting these vulnerabilities to Siemens" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "If malicious cyber actor tricks a user into opening a malicious file with the affected applications, it could allow the cyber actor to crash the application, extract data, or arbitrarily execute code.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "Do not click web links or open attachments in unsolicited email messages.", "title": "Recommended Practices" }, { "category": "general", "text": "Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.", "title": "Recommended Practices" }, { "category": "general", "text": "Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.", "title": "Recommended Practices" }, { "category": "general", "text": "if no known exploits exist, the last sentence of the Mitigation section should include the following.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely. These vulnerabilities have low attack complexity.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-491245.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-047-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-047-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-047-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-047-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/Recommended-Practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://cisa.gov/ics" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" }, { "category": "external", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "category": "external", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-491245.txt" } ], "title": "Siemens Solid Edge", "tracking": { "current_release_date": "2023-02-20T22:10:45.298464Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-047-01", "initial_release_date": "2023-02-20T22:10:45.298464Z", "revision_history": [ { "date": "2023-02-20T22:10:45.298464Z", "legacy_version": "1", "number": "1", "summary": "CSAF Creation Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Solid Edge SE2022", "product_id": "CSAFPID-0001" } }, { "category": "product_version_range", "name": "\u003c V222.0MP12", "product": { "name": "Solid Edge SE2022", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Solid Edge SE2022" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V223.0Update2", "product": { "name": "Solid Edge SE2023", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Solid Edge SE2023" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13408, ZDI-CAN-19072)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32936" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32936" }, { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service (crash). (ZDI-CAN-13378, ZDI-CAN-19073)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32938" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32938" }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DWG files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-19074, ZDI-CAN-13410)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32948" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32948" }, { "cve": "CVE-2021-43336", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15107, ZDI-CAN-19080, ZDI-CAN-19075)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-43336" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-43336" }, { "cve": "CVE-2021-43391", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19082)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-43391" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-43391" }, { "cve": "CVE-2022-46345", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46345" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46345" }, { "cve": "CVE-2022-46346", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46346" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46346" }, { "cve": "CVE-2022-46347", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46347" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46347" }, { "cve": "CVE-2022-46348", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46348" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46348" }, { "cve": "CVE-2022-46349", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-46349" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46349" }, { "cve": "CVE-2023-22295", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19448)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22295" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22295" }, { "cve": "CVE-2023-22321", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19501)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22321" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22321" }, { "cve": "CVE-2023-22354", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products \r\n contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19424)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22354" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22354" }, { "cve": "CVE-2023-22669", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19104)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22669" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22669" }, { "cve": "CVE-2023-22670", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19382)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22670" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22670" }, { "cve": "CVE-2023-22846", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19473)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22846" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22846" }, { "cve": "CVE-2023-23579", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This could allow an attacker to to execute code in the context of the current process. (ZDI-CAN-19423)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-23579" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-23579" }, { "cve": "CVE-2023-24549", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24549" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24549" }, { "cve": "CVE-2023-24550", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to heap-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24550" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24550" }, { "cve": "CVE-2023-24551", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to heap-based buffer underflow while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24551" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24551" }, { "cve": "CVE-2023-24552", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24552" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24552" }, { "cve": "CVE-2023-24553", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24553" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24553" }, { "cve": "CVE-2023-24554", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24554" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24554" }, { "cve": "CVE-2023-24555", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24555" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24555" }, { "cve": "CVE-2023-24556", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24556" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24556" }, { "cve": "CVE-2023-24557", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24557" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24557" }, { "cve": "CVE-2023-24558", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24558" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24558" }, { "cve": "CVE-2023-24559", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24559" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24559" }, { "cve": "CVE-2023-24560", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24560" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24560" }, { "cve": "CVE-2023-24561", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24561" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24561" }, { "cve": "CVE-2023-24562", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24562" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24562" }, { "cve": "CVE-2023-24563", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24563" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24563" }, { "cve": "CVE-2023-24564", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "The affected application contains a memory corruption vulnerability while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19069)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24564" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24564" }, { "cve": "CVE-2023-24565", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24565" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24565" }, { "cve": "CVE-2023-24566", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24566" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24566" }, { "cve": "CVE-2023-24581", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted STP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19425)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-24581" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24581" }, { "cve": "CVE-2023-25140", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-25140" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2023-25140" } ] }
icsa-22-041-07
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Mat Powell" ], "organization": "Trend Micro \u0027s Zero Day Initiative", "summary": "reporting these vulnerabilities to Siemens and CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could lead the application to crash or potentially lead to arbitrary code execution.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation o these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open unsolicited attachments in email messages; Refer to Recognizing and Avoiding Email Scams (https://us-cert.cisa.gov/sites/default/files/publications/emailscams_0905.pdf) for more information on avoiding email scams; Refer to Avoiding Social Engineering and Phishing Attacks (https://us-cert.cisa.gov/ncas/tips/ST04-014) for more information on social engineering attacks.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-301589: Multiple File Parsing Vulnerabilities in Solid Edge, JT2Go and Teamcenter Visualization - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-301589.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-041-07 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-041-07.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-041-07 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-041-07" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams_0905.pdf" }, { "category": "external", "summary": "SSA-301589: Multiple File Parsing Vulnerabilities in Solid Edge, JT2Go and Teamcenter Visualization - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf" }, { "category": "external", "summary": "SSA-301589: Multiple File Parsing Vulnerabilities in Solid Edge, JT2Go and Teamcenter Visualization - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-301589.txt" } ], "title": "Siemens Solid Edge, JT2Go, and Teamcenter Visualization", "tracking": { "current_release_date": "2022-06-16T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-041-07", "initial_release_date": "2022-02-10T00:00:00.000000Z", "revision_history": [ { "date": "2022-02-10T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-22-041-07 Siemens Solid Edge, JT2Go, and Teamcenter Visualization" }, { "date": "2022-03-10T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-22-041-07 Siemens Solid Edge, JT2Go, and Teamcenter Visualization (Update A)" }, { "date": "2022-04-14T00:00:00.000000Z", "legacy_version": "B", "number": "3", "summary": "ICSA-22-041-07 Siemens Solid Edge, JT2Go, and Teamcenter Visualization(Update B) (Update B)" }, { "date": "2022-06-16T00:00:00.000000Z", "legacy_version": "C", "number": "4", "summary": "ICSA-22-041-07 Siemens Solid Edge, JT2Go, and Teamcenter Visualization (Update C)" } ], "status": "final", "version": "4" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V13.2.0.7", "product": { "name": "JT2Go", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "JT2Go" }, { "branches": [ { "category": "product_version_range", "name": "\u003c SE2021MP9", "product": { "name": "Solid Edge SE2021", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Solid Edge SE2021" }, { "branches": [ { "category": "product_version_range", "name": "\u003c SE2022MP1", "product": { "name": "Solid Edge SE2022", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Solid Edge SE2022" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V12.4.0.13", "product": { "name": "Teamcenter Visualization V12.4", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Teamcenter Visualization V12.4" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V13.1.0.8", "product": { "name": "Teamcenter Visualization V13.1", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.1" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V13.1.0.9", "product": { "name": "Teamcenter Visualization V13.1", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.1" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V13.2.0.7", "product": { "name": "Teamcenter Visualization V13.2", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.2" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V13.3.0.1", "product": { "name": "Teamcenter Visualization V13.3", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.3" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-38405", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "The Datalogics APDFL library used in affected products is vulnerable to memory corruption condition while parsing specially crafted PDF files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15106, ZDI-CAN-15108, ZDI-CAN-15113). CVE-2021-38405 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "summary": "CVE-2021-38405 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-38405 - Teamcenter Visualization V12.4", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-38405 - Teamcenter Visualization V13.1", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-38405 - Teamcenter Visualization V13.2", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-38405 - Teamcenter Visualization V13.3", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-38405 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-38405.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-38405" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V12.4.0.13 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.1.0.8 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.1 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in affected products", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2021-38405" }, { "cve": "CVE-2021-43336", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15107). CVE-2021-43336 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "summary": "CVE-2021-43336 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-43336 - Teamcenter Visualization V12.4", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-43336 - Teamcenter Visualization V13.1", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-43336 - Teamcenter Visualization V13.2", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-43336 - Teamcenter Visualization V13.3", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-43336 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-43336.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-43336" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V12.4.0.13 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.1.0.9 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.1 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in affected products", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2021-43336" }, { "cve": "CVE-2021-44000", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053). CVE-2021-44000 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "summary": "CVE-2021-44000 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-44000 - Solid Edge SE2021", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44000 - Solid Edge SE2022", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44000 - Teamcenter Visualization V13.1", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44000 - Teamcenter Visualization V13.2", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44000 - Teamcenter Visualization V13.3", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44000 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-44000.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-44000" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to SE2021MP9 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to SE2022MP1 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.1.0.9 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.1 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in affected products", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2021-44000" }, { "cve": "CVE-2021-44016", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterSE70.dll library is vulnerable to memory corruption condition while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15110). CVE-2021-44016 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "summary": "CVE-2021-44016 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-44016 - Solid Edge SE2021", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44016 - Solid Edge SE2022", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44016 - Teamcenter Visualization V13.1", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44016 - Teamcenter Visualization V13.2", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44016 - Teamcenter Visualization V13.3", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44016 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-44016.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-44016" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to SE2021MP9 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to SE2022MP1 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.1.0.9 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.1 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in affected products", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2021-44016" }, { "cve": "CVE-2021-44018", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterSE70.dll library is vulnerable to memory corruption condition while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15112). CVE-2021-44018 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "summary": "CVE-2021-44018 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-44018 - Solid Edge SE2021", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44018 - Solid Edge SE2022", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44018 - Teamcenter Visualization V13.1", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44018 - Teamcenter Visualization V13.2", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44018 - Teamcenter Visualization V13.3", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44018 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-44018.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-44018" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to SE2021MP9 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to SE2022MP1 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.1.0.9 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.1 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in affected products", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2021-44018" } ] }
ICSA-22-041-07
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Mat Powell" ], "organization": "Trend Micro \u0027s Zero Day Initiative", "summary": "reporting these vulnerabilities to Siemens and CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could lead the application to crash or potentially lead to arbitrary code execution.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation o these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open unsolicited attachments in email messages; Refer to Recognizing and Avoiding Email Scams (https://us-cert.cisa.gov/sites/default/files/publications/emailscams_0905.pdf) for more information on avoiding email scams; Refer to Avoiding Social Engineering and Phishing Attacks (https://us-cert.cisa.gov/ncas/tips/ST04-014) for more information on social engineering attacks.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-301589: Multiple File Parsing Vulnerabilities in Solid Edge, JT2Go and Teamcenter Visualization - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-301589.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-041-07 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-041-07.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-041-07 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-041-07" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams_0905.pdf" }, { "category": "external", "summary": "SSA-301589: Multiple File Parsing Vulnerabilities in Solid Edge, JT2Go and Teamcenter Visualization - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf" }, { "category": "external", "summary": "SSA-301589: Multiple File Parsing Vulnerabilities in Solid Edge, JT2Go and Teamcenter Visualization - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-301589.txt" } ], "title": "Siemens Solid Edge, JT2Go, and Teamcenter Visualization", "tracking": { "current_release_date": "2022-06-16T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-041-07", "initial_release_date": "2022-02-10T00:00:00.000000Z", "revision_history": [ { "date": "2022-02-10T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-22-041-07 Siemens Solid Edge, JT2Go, and Teamcenter Visualization" }, { "date": "2022-03-10T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-22-041-07 Siemens Solid Edge, JT2Go, and Teamcenter Visualization (Update A)" }, { "date": "2022-04-14T00:00:00.000000Z", "legacy_version": "B", "number": "3", "summary": "ICSA-22-041-07 Siemens Solid Edge, JT2Go, and Teamcenter Visualization(Update B) (Update B)" }, { "date": "2022-06-16T00:00:00.000000Z", "legacy_version": "C", "number": "4", "summary": "ICSA-22-041-07 Siemens Solid Edge, JT2Go, and Teamcenter Visualization (Update C)" } ], "status": "final", "version": "4" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V13.2.0.7", "product": { "name": "JT2Go", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "JT2Go" }, { "branches": [ { "category": "product_version_range", "name": "\u003c SE2021MP9", "product": { "name": "Solid Edge SE2021", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Solid Edge SE2021" }, { "branches": [ { "category": "product_version_range", "name": "\u003c SE2022MP1", "product": { "name": "Solid Edge SE2022", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Solid Edge SE2022" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V12.4.0.13", "product": { "name": "Teamcenter Visualization V12.4", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Teamcenter Visualization V12.4" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V13.1.0.8", "product": { "name": "Teamcenter Visualization V13.1", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.1" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V13.1.0.9", "product": { "name": "Teamcenter Visualization V13.1", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.1" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V13.2.0.7", "product": { "name": "Teamcenter Visualization V13.2", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.2" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V13.3.0.1", "product": { "name": "Teamcenter Visualization V13.3", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "Teamcenter Visualization V13.3" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-38405", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "The Datalogics APDFL library used in affected products is vulnerable to memory corruption condition while parsing specially crafted PDF files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15106, ZDI-CAN-15108, ZDI-CAN-15113). CVE-2021-38405 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "summary": "CVE-2021-38405 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-38405 - Teamcenter Visualization V12.4", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-38405 - Teamcenter Visualization V13.1", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-38405 - Teamcenter Visualization V13.2", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-38405 - Teamcenter Visualization V13.3", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-38405 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-38405.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-38405" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V12.4.0.13 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.1.0.8 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.1 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in affected products", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2021-38405" }, { "cve": "CVE-2021-43336", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15107). CVE-2021-43336 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "summary": "CVE-2021-43336 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-43336 - Teamcenter Visualization V12.4", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-43336 - Teamcenter Visualization V13.1", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-43336 - Teamcenter Visualization V13.2", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-43336 - Teamcenter Visualization V13.3", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-43336 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-43336.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-43336" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V12.4.0.13 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.1.0.9 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.1 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in affected products", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2021-43336" }, { "cve": "CVE-2021-44000", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053). CVE-2021-44000 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "summary": "CVE-2021-44000 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-44000 - Solid Edge SE2021", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44000 - Solid Edge SE2022", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44000 - Teamcenter Visualization V13.1", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44000 - Teamcenter Visualization V13.2", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44000 - Teamcenter Visualization V13.3", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44000 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-44000.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-44000" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to SE2021MP9 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to SE2022MP1 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.1.0.9 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.1 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in affected products", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2021-44000" }, { "cve": "CVE-2021-44016", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterSE70.dll library is vulnerable to memory corruption condition while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15110). CVE-2021-44016 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "summary": "CVE-2021-44016 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-44016 - Solid Edge SE2021", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44016 - Solid Edge SE2022", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44016 - Teamcenter Visualization V13.1", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44016 - Teamcenter Visualization V13.2", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44016 - Teamcenter Visualization V13.3", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44016 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-44016.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-44016" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to SE2021MP9 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to SE2022MP1 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.1.0.9 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.1 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in affected products", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2021-44016" }, { "cve": "CVE-2021-44018", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterSE70.dll library is vulnerable to memory corruption condition while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15112). CVE-2021-44018 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "summary": "CVE-2021-44018 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-44018 - Solid Edge SE2021", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44018 - Solid Edge SE2022", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44018 - Teamcenter Visualization V13.1", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44018 - Teamcenter Visualization V13.2", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44018 - Teamcenter Visualization V13.3", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-44018 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-44018.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-44018" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to SE2021MP9 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to SE2022MP1 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.1.0.9 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.2.0.7 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V13.3.0.1 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in affected products", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2021-44018" } ] }
gsd-2021-43336
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2021-43336", "description": "An Out-of-Bounds Write vulnerability exists when reading a DXF file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF files. Crafted data in a DXF file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.", "id": "GSD-2021-43336" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-43336" ], "details": "An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.", "id": "GSD-2021-43336", "modified": "2023-12-13T01:23:26.096792Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-43336", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.opendesign.com/security-advisories", "refsource": "MISC", "url": "https://www.opendesign.com/security-advisories" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-334/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-334/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:opendesign:drawings_software_development_kit:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2022.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:13.1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2022:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.3.0.1", "versionStartIncluding": "13.2.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "12.4.0.13", "versionStartIncluding": "12.4.0", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-43336" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-787" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.opendesign.com/security-advisories", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://www.opendesign.com/security-advisories" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-334/", "refsource": "MISC", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-334/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } }, "lastModifiedDate": "2023-02-24T15:53Z", "publishedDate": "2021-11-14T21:15Z" } } }
ghsa-25gw-crq8-3qhc
Vulnerability from github
An Out-of-Bounds Write vulnerability exists when reading a DXF file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF files. Crafted data in a DXF file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.
{ "affected": [], "aliases": [ "CVE-2021-43336" ], "database_specific": { "cwe_ids": [ "CWE-787" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-11-14T21:15:00Z", "severity": "HIGH" }, "details": "An Out-of-Bounds Write vulnerability exists when reading a DXF file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF files. Crafted data in a DXF file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.", "id": "GHSA-25gw-crq8-3qhc", "modified": "2022-05-24T19:20:38Z", "published": "2022-05-24T19:20:38Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-43336" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "type": "WEB", "url": "https://www.opendesign.com/security-advisories" }, { "type": "WEB", "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-334" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
var-202111-0809
Vulnerability from variot
An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. (DoS) It may be in a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DXF files. The issue results from the lack of validating the existence of an object prior to performing operations on the object
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202111-0809", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "drawing sdk", "scope": null, "trust": 2.8, "vendor": "open design alliance oda", "version": null }, { "model": "solid edge viewer", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "drawings software development kit", "scope": "lt", "trust": 1.0, "vendor": "opendesign", "version": "2022.11" }, { "model": "teamcenter visualization", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "13.3.0.1" }, { "model": "teamcenter visualization", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "13.1.0" }, { "model": "teamcenter visualization", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "13.2.0" }, { "model": "jt2go", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "teamcenter visualization", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "12.4.0.13" }, { "model": "solid edge", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "se2022" }, { "model": "teamcenter visualization", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "12.4.0" }, { "model": "drawings sdk", "scope": "eq", "trust": 0.8, "vendor": "open design alliance", "version": "2022.11" }, { "model": "drawings sdk", "scope": "eq", "trust": 0.8, "vendor": "open design alliance", "version": null }, { "model": "jt2go", "scope": null, "trust": 0.7, "vendor": "siemens", "version": null } ], "sources": [ { "db": "ZDI", "id": "ZDI-22-334" }, { "db": "ZDI", "id": "ZDI-23-127" }, { "db": "ZDI", "id": "ZDI-23-126" }, { "db": "ZDI", "id": "ZDI-23-125" }, { "db": "ZDI", "id": "ZDI-23-210" }, { "db": "ZDI", "id": "ZDI-23-209" }, { "db": "ZDI", "id": "ZDI-23-212" }, { "db": "JVNDB", "id": "JVNDB-2021-007492" }, { "db": "NVD", "id": "CVE-2021-43336" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:opendesign:drawings_software_development_kit:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2022.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:13.1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2022:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.3.0.1", "versionStartIncluding": "13.2.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "12.4.0.13", "versionStartIncluding": "12.4.0", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-43336" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Mat Powell \u0026 Jimmy Calderon (@vectors2final) of Trend Micro Zero Day Initiative", "sources": [ { "db": "ZDI", "id": "ZDI-23-127" }, { "db": "ZDI", "id": "ZDI-23-126" }, { "db": "ZDI", "id": "ZDI-23-125" }, { "db": "ZDI", "id": "ZDI-23-212" } ], "trust": 2.8 }, "cve": "CVE-2021-43336", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-43336", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-43336", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 4.9, "userInteraction": "REQUIRED", "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-43336", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "ZDI", "id": "CVE-2021-43336", "trust": 4.9, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-43336", "trust": 1.8, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202111-1217", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-43336", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-22-334" }, { "db": "ZDI", "id": "ZDI-23-127" }, { "db": "ZDI", "id": "ZDI-23-126" }, { "db": "ZDI", "id": "ZDI-23-125" }, { "db": "ZDI", "id": "ZDI-23-210" }, { "db": "ZDI", "id": "ZDI-23-209" }, { "db": "ZDI", "id": "ZDI-23-212" }, { "db": "VULMON", "id": "CVE-2021-43336" }, { "db": "JVNDB", "id": "JVNDB-2021-007492" }, { "db": "NVD", "id": "CVE-2021-43336" }, { "db": "CNNVD", "id": "CNNVD-202111-1217" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. (DoS) It may be in a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DXF files. The issue results from the lack of validating the existence of an object prior to performing operations on the object", "sources": [ { "db": "NVD", "id": "CVE-2021-43336" }, { "db": "JVNDB", "id": "JVNDB-2021-007492" }, { "db": "ZDI", "id": "ZDI-22-334" }, { "db": "ZDI", "id": "ZDI-23-127" }, { "db": "ZDI", "id": "ZDI-23-126" }, { "db": "ZDI", "id": "ZDI-23-125" }, { "db": "ZDI", "id": "ZDI-23-210" }, { "db": "ZDI", "id": "ZDI-23-209" }, { "db": "ZDI", "id": "ZDI-23-212" }, { "db": "VULMON", "id": "CVE-2021-43336" } ], "trust": 6.12 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-43336", "trust": 8.2 }, { "db": "ZDI", "id": "ZDI-22-334", "trust": 2.4 }, { "db": "SIEMENS", "id": "SSA-301589", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-491245", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-22-041-07", "trust": 1.5 }, { "db": "ICS CERT", "id": "ICSA-23-047-01", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU97514209", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU98748974", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-007492", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-15107", "trust": 0.7 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-19144", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-23-127", "trust": 0.7 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-19143", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-23-126", "trust": 0.7 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-19142", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-23-125", "trust": 0.7 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-19080", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-23-210", "trust": 0.7 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-19075", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-23-209", "trust": 0.7 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-19165", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-23-212", "trust": 0.7 }, { "db": "AUSCERT", "id": "ESB-2023.0960", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022021108", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202111-1217", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-43336", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-22-334" }, { "db": "ZDI", "id": "ZDI-23-127" }, { "db": "ZDI", "id": "ZDI-23-126" }, { "db": "ZDI", "id": "ZDI-23-125" }, { "db": "ZDI", "id": "ZDI-23-210" }, { "db": "ZDI", "id": "ZDI-23-209" }, { "db": "ZDI", "id": "ZDI-23-212" }, { "db": "VULMON", "id": "CVE-2021-43336" }, { "db": "JVNDB", "id": "JVNDB-2021-007492" }, { "db": "NVD", "id": "CVE-2021-43336" }, { "db": "CNNVD", "id": "CNNVD-202111-1217" } ] }, "id": "VAR-202111-0809", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.15799868 }, "last_update_date": "2023-12-18T10:50:00.081000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Vulnerabilities\u00a0in\u00a0the\u00a0ODA\u00a0Drawings\u00a0Software\u00a0Development\u00a0Kit", "trust": 3.6, "url": "https://www.opendesign.com/security-advisories" }, { "title": "Siemens has issued an update to correct this vulnerability.", "trust": 1.4, "url": "https://cert-portal.siemens.com/productcert/html/ssa-491245.html" }, { "title": "Siemens has issued an update to correct this vulnerability.", "trust": 0.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf" }, { "title": "Open Design Alliance Drawings SDK Buffer error vulnerability fix", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=170359" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=fefc850707fc7ccce29d30c42162ee31" }, { "title": "", "trust": 0.1, "url": "https://github.com/live-hack-cve/cve-2021-43336 " } ], "sources": [ { "db": "ZDI", "id": "ZDI-22-334" }, { "db": "ZDI", "id": "ZDI-23-127" }, { "db": "ZDI", "id": "ZDI-23-126" }, { "db": "ZDI", "id": "ZDI-23-125" }, { "db": "ZDI", "id": "ZDI-23-210" }, { "db": "ZDI", "id": "ZDI-23-209" }, { "db": "ZDI", "id": "ZDI-23-212" }, { "db": "VULMON", "id": "CVE-2021-43336" }, { "db": "JVNDB", "id": "JVNDB-2021-007492" }, { "db": "CNNVD", "id": "CNNVD-202111-1217" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-007492" }, { "db": "NVD", "id": "CVE-2021-43336" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 4.5, "url": "https://www.opendesign.com/security-advisories" }, { "trust": 2.4, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf" }, { "trust": 2.4, "url": "https://www.zerodayinitiative.com/advisories/zdi-22-334/" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "trust": 1.4, "url": "https://cert-portal.siemens.com/productcert/html/ssa-491245.html" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-43336" }, { "trust": 0.9, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-041-07" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu98748974/" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu97514209/index.html" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-047-01" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022021108" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2023.0960" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-041-07-1" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-041-07-0" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://github.com/live-hack-cve/cve-2021-43336" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "ZDI", "id": "ZDI-22-334" }, { "db": "ZDI", "id": "ZDI-23-127" }, { "db": "ZDI", "id": "ZDI-23-126" }, { "db": "ZDI", "id": "ZDI-23-125" }, { "db": "ZDI", "id": "ZDI-23-210" }, { "db": "ZDI", "id": "ZDI-23-209" }, { "db": "ZDI", "id": "ZDI-23-212" }, { "db": "VULMON", "id": "CVE-2021-43336" }, { "db": "JVNDB", "id": "JVNDB-2021-007492" }, { "db": "NVD", "id": "CVE-2021-43336" }, { "db": "CNNVD", "id": "CNNVD-202111-1217" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "ZDI", "id": "ZDI-22-334" }, { "db": "ZDI", "id": "ZDI-23-127" }, { "db": "ZDI", "id": "ZDI-23-126" }, { "db": "ZDI", "id": "ZDI-23-125" }, { "db": "ZDI", "id": "ZDI-23-210" }, { "db": "ZDI", "id": "ZDI-23-209" }, { "db": "ZDI", "id": "ZDI-23-212" }, { "db": "VULMON", "id": "CVE-2021-43336" }, { "db": "JVNDB", "id": "JVNDB-2021-007492" }, { "db": "NVD", "id": "CVE-2021-43336" }, { "db": "CNNVD", "id": "CNNVD-202111-1217" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-02-15T00:00:00", "db": "ZDI", "id": "ZDI-22-334" }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-127" }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-126" }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-125" }, { "date": "2023-03-01T00:00:00", "db": "ZDI", "id": "ZDI-23-210" }, { "date": "2023-03-01T00:00:00", "db": "ZDI", "id": "ZDI-23-209" }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-212" }, { "date": "2021-11-14T00:00:00", "db": "VULMON", "id": "CVE-2021-43336" }, { "date": "2022-02-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-007492" }, { "date": "2021-11-14T21:15:08.263000", "db": "NVD", "id": "CVE-2021-43336" }, { "date": "2021-11-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202111-1217" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-02-15T00:00:00", "db": "ZDI", "id": "ZDI-22-334" }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-127" }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-126" }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-125" }, { "date": "2023-03-01T00:00:00", "db": "ZDI", "id": "ZDI-23-210" }, { "date": "2023-03-01T00:00:00", "db": "ZDI", "id": "ZDI-23-209" }, { "date": "2023-03-06T00:00:00", "db": "ZDI", "id": "ZDI-23-212" }, { "date": "2023-02-24T00:00:00", "db": "VULMON", "id": "CVE-2021-43336" }, { "date": "2023-02-17T02:09:00", "db": "JVNDB", "id": "JVNDB-2021-007492" }, { "date": "2023-02-24T15:53:38.813000", "db": "NVD", "id": "CVE-2021-43336" }, { "date": "2023-02-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202111-1217" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202111-1217" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Open Design Alliance (ODA) Drawing SDK DXF File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability", "sources": [ { "db": "ZDI", "id": "ZDI-23-127" }, { "db": "ZDI", "id": "ZDI-23-126" } ], "trust": 1.4 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202111-1217" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.