Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2021-43336 (GCVE-0-2021-43336)
Vulnerability from cvelistv5 – Published: 2021-11-14 00:00 – Updated: 2024-08-04 03:55- n/a
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T03:55:28.546Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.opendesign.com/security-advisories"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-334/"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-14T00:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.opendesign.com/security-advisories"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-334/"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-43336",
"datePublished": "2021-11-14T00:00:00.000Z",
"dateReserved": "2021-11-03T00:00:00.000Z",
"dateUpdated": "2024-08-04T03:55:28.546Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-43336",
"date": "2026-06-10",
"epss": "0.00347",
"percentile": "0.57629"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:opendesign:drawings_software_development_kit:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2022.11\", \"matchCriteriaId\": \"2517E46B-54DB-49E1-88DB-905365792054\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C51D6378-471B-45B2-9666-1AA4FB509E7A\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2022:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"61866294-2060-457C-9CBE-8AEAF03973F6\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"12.4.0\", \"versionEndExcluding\": \"12.4.0.13\", \"matchCriteriaId\": \"BAAA3630-3C59-43E8-9793-B3DD3276B58C\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"13.2.0\", \"versionEndExcluding\": \"13.3.0.1\", \"matchCriteriaId\": \"CFBB1E39-FCCF-4F33-ADB4-74849D0E65CB\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:teamcenter_visualization:13.1.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A817DDD3-A448-46FE-8232-21E307A677F9\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.\"}, {\"lang\": \"es\", \"value\": \"Se presenta una vulnerabilidad de escritura fuera de l\\u00edmites cuando es le\\u00eddo un archivo DXF usando Open Design Alliance Drawings SDK versiones anteriores a 2022.11. El problema espec\\u00edfico es presentado dentro del an\\u00e1lisis de los archivos DXF. Los datos dise\\u00f1ados en un archivo DXF (un n\\u00famero no v\\u00e1lido de propiedades) pueden desencadenar una operaci\\u00f3n de escritura m\\u00e1s all\\u00e1 del final de un b\\u00fafer asignado. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\\u00f3digo en el contexto del proceso actual\"}]",
"id": "CVE-2021-43336",
"lastModified": "2024-11-21T06:29:06.483",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2021-11-14T21:15:08.263",
"references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.opendesign.com/security-advisories\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-22-334/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.opendesign.com/security-advisories\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-22-334/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-43336\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-11-14T21:15:08.263\",\"lastModified\":\"2024-11-21T06:29:06.483\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se presenta una vulnerabilidad de escritura fuera de l\u00edmites cuando es le\u00eddo un archivo DXF usando Open Design Alliance Drawings SDK versiones anteriores a 2022.11. El problema espec\u00edfico es presentado dentro del an\u00e1lisis de los archivos DXF. Los datos dise\u00f1ados en un archivo DXF (un n\u00famero no v\u00e1lido de propiedades) pueden desencadenar una operaci\u00f3n de escritura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opendesign:drawings_software_development_kit:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.11\",\"matchCriteriaId\":\"2517E46B-54DB-49E1-88DB-905365792054\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C51D6378-471B-45B2-9666-1AA4FB509E7A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2022:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"61866294-2060-457C-9CBE-8AEAF03973F6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.4.0\",\"versionEndExcluding\":\"12.4.0.13\",\"matchCriteriaId\":\"BAAA3630-3C59-43E8-9793-B3DD3276B58C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.0\",\"versionEndExcluding\":\"13.3.0.1\",\"matchCriteriaId\":\"CFBB1E39-FCCF-4F33-ADB4-74849D0E65CB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:13.1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A817DDD3-A448-46FE-8232-21E307A677F9\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.opendesign.com/security-advisories\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-22-334/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.opendesign.com/security-advisories\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-22-334/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}"
}
}
ICSA-23-047-01
Vulnerability from csaf_cisa - Published: 2023-02-14 00:00 - Updated: 2023-03-14 00:00{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
},
{
"organization": "Michael Heinzl",
"summary": "coordinating disclosure of vulnerabilities from CVE-2023-24549 to CVE-2023-24563 and CVE-2023-25140"
},
{
"organization": "Trend Micro Zero Day Initiative",
"summary": "coordinating disclosure of CVE-2023-24564, CVE-2023-22670, CVE-2022-46348, CVE-2022-46345, CVE-2022-46346, CVE-2022-46349, CVE-2022-46347, CVE-2023-24565, CVE-2023-24566, CVE-2023-23579, CVE-2023-22354, CVE-2023-22295, CVE-2023-22321 and CVE-2023-22846"
},
{
"organization": "Open Design Alliance",
"summary": "coordination efforts of CVE-2021-43336, CVE-2021-32938, CVE-2021-32948, CVE-2021-43391, CVE-2021-32936, CVE-2023-22669 and CVE-2023-22670"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "Solid Edge is affected by multiple memory corruption vulnerabilities that could be triggered when the application reads specially crafted files in various formats such as X_B, DWG, DXF, STL, STP, SLDPRT and PAR format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to crash the application, extract data or potentially lead to arbitrary code execution.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-491245.json"
},
{
"category": "self",
"summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-491245.txt"
},
{
"category": "self",
"summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-047-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-047-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-047-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-047-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens Solid Edge",
"tracking": {
"current_release_date": "2023-03-14T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-047-01",
"initial_release_date": "2023-02-14T00:00:00.000000Z",
"revision_history": [
{
"date": "2023-02-14T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2023-03-14T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Correction in version formats of fixes"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Solid Edge SE2022",
"product_id": "CSAFPID-0001"
}
},
{
"category": "product_version_range",
"name": "\u003cV222.0MP12",
"product": {
"name": "Solid Edge SE2022",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2022"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV223.0Update2",
"product": {
"name": "Solid Edge SE2023",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2023"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-32936",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13408, ZDI-CAN-19072)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2021-32936"
},
{
"cve": "CVE-2021-32938",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service (crash). (ZDI-CAN-13378, ZDI-CAN-19073)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2021-32938"
},
{
"cve": "CVE-2021-32948",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DWG files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-19074, ZDI-CAN-13410)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2021-32948"
},
{
"cve": "CVE-2021-43336",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15107, ZDI-CAN-19080, ZDI-CAN-19075)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2021-43336"
},
{
"cve": "CVE-2021-43391",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19082)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2021-43391"
},
{
"cve": "CVE-2022-46345",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2022-46345"
},
{
"cve": "CVE-2022-46346",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2022-46346"
},
{
"cve": "CVE-2022-46347",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2022-46347"
},
{
"cve": "CVE-2022-46348",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2022-46348"
},
{
"cve": "CVE-2022-46349",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2022-46349"
},
{
"cve": "CVE-2023-22295",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19448)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-22295"
},
{
"cve": "CVE-2023-22321",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19501)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-22321"
},
{
"cve": "CVE-2023-22354",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products \r\n contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19424)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-22354"
},
{
"cve": "CVE-2023-22669",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19104)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-22669"
},
{
"cve": "CVE-2023-22670",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19382)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-22670"
},
{
"cve": "CVE-2023-22846",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19473)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-22846"
},
{
"cve": "CVE-2023-23579",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This could allow an attacker to to execute code in the context of the current process. (ZDI-CAN-19423)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-23579"
},
{
"cve": "CVE-2023-24549",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24549"
},
{
"cve": "CVE-2023-24550",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to heap-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24550"
},
{
"cve": "CVE-2023-24551",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to heap-based buffer underflow while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24551"
},
{
"cve": "CVE-2023-24552",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24552"
},
{
"cve": "CVE-2023-24553",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24553"
},
{
"cve": "CVE-2023-24554",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24554"
},
{
"cve": "CVE-2023-24555",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24555"
},
{
"cve": "CVE-2023-24556",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24556"
},
{
"cve": "CVE-2023-24557",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24557"
},
{
"cve": "CVE-2023-24558",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24558"
},
{
"cve": "CVE-2023-24559",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24559"
},
{
"cve": "CVE-2023-24560",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24560"
},
{
"cve": "CVE-2023-24561",
"cwe": {
"id": "CWE-824",
"name": "Access of Uninitialized Pointer"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24561"
},
{
"cve": "CVE-2023-24562",
"cwe": {
"id": "CWE-824",
"name": "Access of Uninitialized Pointer"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24562"
},
{
"cve": "CVE-2023-24563",
"cwe": {
"id": "CWE-824",
"name": "Access of Uninitialized Pointer"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24563"
},
{
"cve": "CVE-2023-24564",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains a memory corruption vulnerability while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19069)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24564"
},
{
"cve": "CVE-2023-24565",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24565"
},
{
"cve": "CVE-2023-24566",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24566"
},
{
"cve": "CVE-2023-24581",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted STP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19425)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-24581"
},
{
"cve": "CVE-2023-25140",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
],
"title": "CVE-2023-25140"
}
]
}
SSA-301589
Vulnerability from csaf_siemens - Published: 2022-02-08 00:00 - Updated: 2022-06-14 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
JT2Go
Siemens / JT2Go
|
< V13.2.0.7 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V12.4
Siemens / Teamcenter Visualization V12.4
|
< V12.4.0.13 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.1
Siemens / Teamcenter Visualization V13.1
|
< V13.1.0.8 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.2
Siemens / Teamcenter Visualization V13.2
|
< V13.2.0.7 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.3
Siemens / Teamcenter Visualization V13.3
|
< V13.3.0.1 |
Vendor Fix
fix
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
JT2Go
Siemens / JT2Go
|
< V13.2.0.7 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V12.4
Siemens / Teamcenter Visualization V12.4
|
< V12.4.0.13 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.1
Siemens / Teamcenter Visualization V13.1
|
< V13.1.0.9 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.2
Siemens / Teamcenter Visualization V13.2
|
< V13.2.0.7 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.3
Siemens / Teamcenter Visualization V13.3
|
< V13.3.0.1 |
Vendor Fix
fix
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
JT2Go
Siemens / JT2Go
|
< V13.2.0.7 |
Vendor Fix
fix
Mitigation
|
|
|
Solid Edge SE2021
Siemens / Solid Edge SE2021
|
< SE2021MP9 |
Vendor Fix
fix
Mitigation
|
|
|
Solid Edge SE2022
Siemens / Solid Edge SE2022
|
< SE2022MP1 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.1
Siemens / Teamcenter Visualization V13.1
|
< V13.1.0.9 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.2
Siemens / Teamcenter Visualization V13.2
|
< V13.2.0.7 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.3
Siemens / Teamcenter Visualization V13.3
|
< V13.3.0.1 |
Vendor Fix
fix
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
JT2Go
Siemens / JT2Go
|
< V13.2.0.7 |
Vendor Fix
fix
Mitigation
|
|
|
Solid Edge SE2021
Siemens / Solid Edge SE2021
|
< SE2021MP9 |
Vendor Fix
fix
Mitigation
|
|
|
Solid Edge SE2022
Siemens / Solid Edge SE2022
|
< SE2022MP1 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.1
Siemens / Teamcenter Visualization V13.1
|
< V13.1.0.9 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.2
Siemens / Teamcenter Visualization V13.2
|
< V13.2.0.7 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.3
Siemens / Teamcenter Visualization V13.3
|
< V13.3.0.1 |
Vendor Fix
fix
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
JT2Go
Siemens / JT2Go
|
< V13.2.0.7 |
Vendor Fix
fix
Mitigation
|
|
|
Solid Edge SE2021
Siemens / Solid Edge SE2021
|
< SE2021MP9 |
Vendor Fix
fix
Mitigation
|
|
|
Solid Edge SE2022
Siemens / Solid Edge SE2022
|
< SE2022MP1 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.1
Siemens / Teamcenter Visualization V13.1
|
< V13.1.0.9 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.2
Siemens / Teamcenter Visualization V13.2
|
< V13.2.0.7 |
Vendor Fix
fix
Mitigation
|
|
|
Teamcenter Visualization V13.3
Siemens / Teamcenter Visualization V13.3
|
< V13.3.0.1 |
Vendor Fix
fix
Mitigation
|
{
"document": {
"acknowledgments": [
{
"organization": "Trend Micro Zero Day Initiative",
"summary": "coordinated disclosure"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "Siemens has released updates for JT2Go, Solid Edge and Teamcenter Visualization to fix multiple file parsing vulnerabilities. If a user is tricked to open a malicious file (crafted as PDF, DXF or PAR) with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution.\n\nSiemens has released updates for some of the affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products where updates are not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-301589: Multiple File Parsing Vulnerabilities in Solid Edge, JT2Go and Teamcenter Visualization - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf"
},
{
"category": "self",
"summary": "SSA-301589: Multiple File Parsing Vulnerabilities in Solid Edge, JT2Go and Teamcenter Visualization - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-301589.txt"
},
{
"category": "self",
"summary": "SSA-301589: Multiple File Parsing Vulnerabilities in Solid Edge, JT2Go and Teamcenter Visualization - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-301589.json"
}
],
"title": "SSA-301589: Multiple File Parsing Vulnerabilities in Solid Edge, JT2Go and Teamcenter Visualization",
"tracking": {
"current_release_date": "2022-06-14T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-301589",
"initial_release_date": "2022-02-08T00:00:00Z",
"revision_history": [
{
"date": "2022-02-08T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2022-03-08T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added remediation for Teamcenter Visualization version lines V12.4 and V13.3"
},
{
"date": "2022-04-12T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added remediation for Teamcenter Visualization version line V13.2 and JT2Go"
},
{
"date": "2022-06-14T00:00:00Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added fix for CVE-2021-43336, CVE-2021-44000, CVE-2021-44016 and CVE-2021-44018 in Teamcenter Visualization version line V13.1"
}
],
"status": "final",
"version": "4"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.2.0.7",
"product": {
"name": "JT2Go",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "JT2Go"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c SE2021MP9",
"product": {
"name": "Solid Edge SE2021",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2021"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c SE2022MP1",
"product": {
"name": "Solid Edge SE2022",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2022"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V12.4.0.13",
"product": {
"name": "Teamcenter Visualization V12.4",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Teamcenter Visualization V12.4"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.1.0.8",
"product": {
"name": "Teamcenter Visualization V13.1",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "Teamcenter Visualization V13.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.1.0.9",
"product": {
"name": "Teamcenter Visualization V13.1",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "Teamcenter Visualization V13.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.2.0.7",
"product": {
"name": "Teamcenter Visualization V13.2",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "Teamcenter Visualization V13.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.3.0.1",
"product": {
"name": "Teamcenter Visualization V13.3",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "Teamcenter Visualization V13.3"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-38405",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "The Datalogics APDFL library used in affected products is vulnerable to memory corruption condition while parsing specially crafted PDF files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15106, ZDI-CAN-15108, ZDI-CAN-15113)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"4",
"5",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2021-38405 - JT2Go",
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"summary": "CVE-2021-38405 - Teamcenter Visualization V12.4",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-38405 - Teamcenter Visualization V13.1",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-38405 - Teamcenter Visualization V13.2",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-38405 - Teamcenter Visualization V13.3",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-38405 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-38405.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V13.2.0.7 or later version",
"product_ids": [
"1"
],
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"category": "vendor_fix",
"details": "Update to V12.4.0.13 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.1.0.8 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.7 or later version",
"product_ids": [
"7"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.3.0.1 or later version",
"product_ids": [
"8"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in affected products",
"product_ids": [
"1",
"4",
"5",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"4",
"5",
"7",
"8"
]
}
],
"title": "CVE-2021-38405"
},
{
"cve": "CVE-2021-43336",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15107)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"4",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2021-43336 - JT2Go",
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"summary": "CVE-2021-43336 - Teamcenter Visualization V12.4",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-43336 - Teamcenter Visualization V13.1",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-43336 - Teamcenter Visualization V13.2",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-43336 - Teamcenter Visualization V13.3",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-43336 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-43336.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V13.2.0.7 or later version",
"product_ids": [
"1"
],
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"category": "vendor_fix",
"details": "Update to V12.4.0.13 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.1.0.9 or later version",
"product_ids": [
"6"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.7 or later version",
"product_ids": [
"7"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.3.0.1 or later version",
"product_ids": [
"8"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in affected products",
"product_ids": [
"1",
"4",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"4",
"6",
"7",
"8"
]
}
],
"title": "CVE-2021-43336"
},
{
"cve": "CVE-2021-44000",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The plmxmlAdapterSE70.dll contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15053)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2021-44000 - JT2Go",
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"summary": "CVE-2021-44000 - Solid Edge SE2021",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44000 - Solid Edge SE2022",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44000 - Teamcenter Visualization V13.1",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44000 - Teamcenter Visualization V13.2",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44000 - Teamcenter Visualization V13.3",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44000 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-44000.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V13.2.0.7 or later version",
"product_ids": [
"1"
],
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP9 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to SE2022MP1 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.1.0.9 or later version",
"product_ids": [
"6"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.7 or later version",
"product_ids": [
"7"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.3.0.1 or later version",
"product_ids": [
"8"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in affected products",
"product_ids": [
"1",
"2",
"3",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"6",
"7",
"8"
]
}
],
"title": "CVE-2021-44000"
},
{
"cve": "CVE-2021-44016",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "The plmxmlAdapterSE70.dll library is vulnerable to memory corruption condition while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15110)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2021-44016 - JT2Go",
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"summary": "CVE-2021-44016 - Solid Edge SE2021",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44016 - Solid Edge SE2022",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44016 - Teamcenter Visualization V13.1",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44016 - Teamcenter Visualization V13.2",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44016 - Teamcenter Visualization V13.3",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44016 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-44016.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V13.2.0.7 or later version",
"product_ids": [
"1"
],
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP9 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to SE2022MP1 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.1.0.9 or later version",
"product_ids": [
"6"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.7 or later version",
"product_ids": [
"7"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.3.0.1 or later version",
"product_ids": [
"8"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in affected products",
"product_ids": [
"1",
"2",
"3",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"6",
"7",
"8"
]
}
],
"title": "CVE-2021-44016"
},
{
"cve": "CVE-2021-44018",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The plmxmlAdapterSE70.dll library is vulnerable to memory corruption condition while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15112)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"6",
"7",
"8"
]
},
"references": [
{
"summary": "CVE-2021-44018 - JT2Go",
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"summary": "CVE-2021-44018 - Solid Edge SE2021",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44018 - Solid Edge SE2022",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44018 - Teamcenter Visualization V13.1",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44018 - Teamcenter Visualization V13.2",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44018 - Teamcenter Visualization V13.3",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2021-44018 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-44018.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V13.2.0.7 or later version",
"product_ids": [
"1"
],
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP9 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to SE2022MP1 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.1.0.9 or later version",
"product_ids": [
"6"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.7 or later version",
"product_ids": [
"7"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.3.0.1 or later version",
"product_ids": [
"8"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in affected products",
"product_ids": [
"1",
"2",
"3",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"6",
"7",
"8"
]
}
],
"title": "CVE-2021-44018"
}
]
}
SSA-491245
Vulnerability from csaf_siemens - Published: 2023-02-14 00:00 - Updated: 2023-03-14 00:00{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "Solid Edge is affected by multiple memory corruption vulnerabilities that could be triggered when the application reads specially crafted files in various formats such as X_B, DWG, DXF, STL, STP, SLDPRT and PAR format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to crash the application, extract data or potentially lead to arbitrary code execution.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
},
{
"category": "self",
"summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-491245.txt"
},
{
"category": "self",
"summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-491245.json"
}
],
"title": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge",
"tracking": {
"current_release_date": "2023-03-14T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-491245",
"initial_release_date": "2023-02-14T00:00:00Z",
"revision_history": [
{
"date": "2023-02-14T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2023-03-14T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Correction in version formats of fixes"
}
],
"status": "interim",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Solid Edge SE2022",
"product_id": "1"
}
},
{
"category": "product_version_range",
"name": "\u003c V222.0MP12",
"product": {
"name": "Solid Edge SE2022",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2022"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V223.0Update2",
"product": {
"name": "Solid Edge SE2023",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2023"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-32936",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13408, ZDI-CAN-19072)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2"
]
}
],
"title": "CVE-2021-32936"
},
{
"cve": "CVE-2021-32938",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service (crash). (ZDI-CAN-13378, ZDI-CAN-19073)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2"
]
}
],
"title": "CVE-2021-32938"
},
{
"cve": "CVE-2021-32948",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DWG files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-19074, ZDI-CAN-13410)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2"
]
}
],
"title": "CVE-2021-32948"
},
{
"cve": "CVE-2021-43336",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15107, ZDI-CAN-19080, ZDI-CAN-19075)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2"
]
}
],
"title": "CVE-2021-43336"
},
{
"cve": "CVE-2021-43391",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19082)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2"
]
}
],
"title": "CVE-2021-43391"
},
{
"cve": "CVE-2022-46345",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2022-46345"
},
{
"cve": "CVE-2022-46346",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2022-46346"
},
{
"cve": "CVE-2022-46347",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2022-46347"
},
{
"cve": "CVE-2022-46348",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2022-46348"
},
{
"cve": "CVE-2022-46349",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2022-46349"
},
{
"cve": "CVE-2023-22295",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19448)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-22295"
},
{
"cve": "CVE-2023-22321",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19501)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-22321"
},
{
"cve": "CVE-2023-22354",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products \r\n contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19424)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-22354"
},
{
"cve": "CVE-2023-22669",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19104)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-22669"
},
{
"cve": "CVE-2023-22670",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19382)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-22670"
},
{
"cve": "CVE-2023-22846",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19473)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-22846"
},
{
"cve": "CVE-2023-23579",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This could allow an attacker to to execute code in the context of the current process. (ZDI-CAN-19423)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-23579"
},
{
"cve": "CVE-2023-24549",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24549"
},
{
"cve": "CVE-2023-24550",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to heap-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24550"
},
{
"cve": "CVE-2023-24551",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to heap-based buffer underflow while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24551"
},
{
"cve": "CVE-2023-24552",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24552"
},
{
"cve": "CVE-2023-24553",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24553"
},
{
"cve": "CVE-2023-24554",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24554"
},
{
"cve": "CVE-2023-24555",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24555"
},
{
"cve": "CVE-2023-24556",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24556"
},
{
"cve": "CVE-2023-24557",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24557"
},
{
"cve": "CVE-2023-24558",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24558"
},
{
"cve": "CVE-2023-24559",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24559"
},
{
"cve": "CVE-2023-24560",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24560"
},
{
"cve": "CVE-2023-24561",
"cwe": {
"id": "CWE-824",
"name": "Access of Uninitialized Pointer"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24561"
},
{
"cve": "CVE-2023-24562",
"cwe": {
"id": "CWE-824",
"name": "Access of Uninitialized Pointer"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24562"
},
{
"cve": "CVE-2023-24563",
"cwe": {
"id": "CWE-824",
"name": "Access of Uninitialized Pointer"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24563"
},
{
"cve": "CVE-2023-24564",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains a memory corruption vulnerability while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19069)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-24564"
},
{
"cve": "CVE-2023-24565",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-24565"
},
{
"cve": "CVE-2023-24566",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-24566"
},
{
"cve": "CVE-2023-24581",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted STP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19425)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-24581"
},
{
"cve": "CVE-2023-25140",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2"
]
}
],
"title": "CVE-2023-25140"
}
]
}
VAR-202111-0809
Vulnerability from variot - Updated: 2023-12-18 10:50An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. (DoS) It may be in a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DXF files. The issue results from the lack of validating the existence of an object prior to performing operations on the object
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202111-0809",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "drawing sdk",
"scope": null,
"trust": 2.8,
"vendor": "open design alliance oda",
"version": null
},
{
"model": "solid edge viewer",
"scope": null,
"trust": 1.4,
"vendor": "siemens",
"version": null
},
{
"model": "drawings software development kit",
"scope": "lt",
"trust": 1.0,
"vendor": "opendesign",
"version": "2022.11"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "13.3.0.1"
},
{
"model": "teamcenter visualization",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "13.1.0"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "13.2.0"
},
{
"model": "jt2go",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "12.4.0.13"
},
{
"model": "solid edge",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "se2022"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "12.4.0"
},
{
"model": "drawings sdk",
"scope": "eq",
"trust": 0.8,
"vendor": "open design alliance",
"version": "2022.11"
},
{
"model": "drawings sdk",
"scope": "eq",
"trust": 0.8,
"vendor": "open design alliance",
"version": null
},
{
"model": "jt2go",
"scope": null,
"trust": 0.7,
"vendor": "siemens",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-22-334"
},
{
"db": "ZDI",
"id": "ZDI-23-127"
},
{
"db": "ZDI",
"id": "ZDI-23-126"
},
{
"db": "ZDI",
"id": "ZDI-23-125"
},
{
"db": "ZDI",
"id": "ZDI-23-210"
},
{
"db": "ZDI",
"id": "ZDI-23-209"
},
{
"db": "ZDI",
"id": "ZDI-23-212"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-007492"
},
{
"db": "NVD",
"id": "CVE-2021-43336"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:opendesign:drawings_software_development_kit:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2022.11",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:13.1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2022:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "13.3.0.1",
"versionStartIncluding": "13.2.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "12.4.0.13",
"versionStartIncluding": "12.4.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-43336"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mat Powell \u0026 Jimmy Calderon (@vectors2final) of Trend Micro Zero Day Initiative",
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-127"
},
{
"db": "ZDI",
"id": "ZDI-23-126"
},
{
"db": "ZDI",
"id": "ZDI-23-125"
},
{
"db": "ZDI",
"id": "ZDI-23-212"
}
],
"trust": 2.8
},
"cve": "CVE-2021-43336",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.8,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2021-43336",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2021-43336",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 4.9,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-43336",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "ZDI",
"id": "CVE-2021-43336",
"trust": 4.9,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2021-43336",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202111-1217",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2021-43336",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-22-334"
},
{
"db": "ZDI",
"id": "ZDI-23-127"
},
{
"db": "ZDI",
"id": "ZDI-23-126"
},
{
"db": "ZDI",
"id": "ZDI-23-125"
},
{
"db": "ZDI",
"id": "ZDI-23-210"
},
{
"db": "ZDI",
"id": "ZDI-23-209"
},
{
"db": "ZDI",
"id": "ZDI-23-212"
},
{
"db": "VULMON",
"id": "CVE-2021-43336"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-007492"
},
{
"db": "NVD",
"id": "CVE-2021-43336"
},
{
"db": "CNNVD",
"id": "CNNVD-202111-1217"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. (DoS) It may be in a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DXF files. The issue results from the lack of validating the existence of an object prior to performing operations on the object",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-43336"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-007492"
},
{
"db": "ZDI",
"id": "ZDI-22-334"
},
{
"db": "ZDI",
"id": "ZDI-23-127"
},
{
"db": "ZDI",
"id": "ZDI-23-126"
},
{
"db": "ZDI",
"id": "ZDI-23-125"
},
{
"db": "ZDI",
"id": "ZDI-23-210"
},
{
"db": "ZDI",
"id": "ZDI-23-209"
},
{
"db": "ZDI",
"id": "ZDI-23-212"
},
{
"db": "VULMON",
"id": "CVE-2021-43336"
}
],
"trust": 6.12
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-43336",
"trust": 8.2
},
{
"db": "ZDI",
"id": "ZDI-22-334",
"trust": 2.4
},
{
"db": "SIEMENS",
"id": "SSA-301589",
"trust": 1.7
},
{
"db": "SIEMENS",
"id": "SSA-491245",
"trust": 1.7
},
{
"db": "ICS CERT",
"id": "ICSA-22-041-07",
"trust": 1.5
},
{
"db": "ICS CERT",
"id": "ICSA-23-047-01",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU97514209",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU98748974",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2021-007492",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-15107",
"trust": 0.7
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-19144",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-23-127",
"trust": 0.7
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-19143",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-23-126",
"trust": 0.7
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-19142",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-23-125",
"trust": 0.7
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-19080",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-23-210",
"trust": 0.7
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-19075",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-23-209",
"trust": 0.7
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-19165",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-23-212",
"trust": 0.7
},
{
"db": "AUSCERT",
"id": "ESB-2023.0960",
"trust": 0.6
},
{
"db": "CS-HELP",
"id": "SB2022021108",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202111-1217",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2021-43336",
"trust": 0.1
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-22-334"
},
{
"db": "ZDI",
"id": "ZDI-23-127"
},
{
"db": "ZDI",
"id": "ZDI-23-126"
},
{
"db": "ZDI",
"id": "ZDI-23-125"
},
{
"db": "ZDI",
"id": "ZDI-23-210"
},
{
"db": "ZDI",
"id": "ZDI-23-209"
},
{
"db": "ZDI",
"id": "ZDI-23-212"
},
{
"db": "VULMON",
"id": "CVE-2021-43336"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-007492"
},
{
"db": "NVD",
"id": "CVE-2021-43336"
},
{
"db": "CNNVD",
"id": "CNNVD-202111-1217"
}
]
},
"id": "VAR-202111-0809",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.15799868
},
"last_update_date": "2023-12-18T10:50:00.081000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Vulnerabilities\u00a0in\u00a0the\u00a0ODA\u00a0Drawings\u00a0Software\u00a0Development\u00a0Kit",
"trust": 3.6,
"url": "https://www.opendesign.com/security-advisories"
},
{
"title": "Siemens has issued an update to correct this vulnerability.",
"trust": 1.4,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-491245.html"
},
{
"title": "Siemens has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf"
},
{
"title": "Open Design Alliance Drawings SDK Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=170359"
},
{
"title": "Siemens Security Advisories: Siemens Security Advisory",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=fefc850707fc7ccce29d30c42162ee31"
},
{
"title": "",
"trust": 0.1,
"url": "https://github.com/live-hack-cve/cve-2021-43336 "
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-22-334"
},
{
"db": "ZDI",
"id": "ZDI-23-127"
},
{
"db": "ZDI",
"id": "ZDI-23-126"
},
{
"db": "ZDI",
"id": "ZDI-23-125"
},
{
"db": "ZDI",
"id": "ZDI-23-210"
},
{
"db": "ZDI",
"id": "ZDI-23-209"
},
{
"db": "ZDI",
"id": "ZDI-23-212"
},
{
"db": "VULMON",
"id": "CVE-2021-43336"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-007492"
},
{
"db": "CNNVD",
"id": "CNNVD-202111-1217"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-007492"
},
{
"db": "NVD",
"id": "CVE-2021-43336"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 4.5,
"url": "https://www.opendesign.com/security-advisories"
},
{
"trust": 2.4,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf"
},
{
"trust": 2.4,
"url": "https://www.zerodayinitiative.com/advisories/zdi-22-334/"
},
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
},
{
"trust": 1.4,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-491245.html"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-43336"
},
{
"trust": 0.9,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-041-07"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu98748974/"
},
{
"trust": 0.8,
"url": "http://jvn.jp/vu/jvnvu97514209/index.html"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-047-01"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2022021108"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2023.0960"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-041-07-1"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-041-07-0"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"trust": 0.1,
"url": "https://github.com/live-hack-cve/cve-2021-43336"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-22-334"
},
{
"db": "ZDI",
"id": "ZDI-23-127"
},
{
"db": "ZDI",
"id": "ZDI-23-126"
},
{
"db": "ZDI",
"id": "ZDI-23-125"
},
{
"db": "ZDI",
"id": "ZDI-23-210"
},
{
"db": "ZDI",
"id": "ZDI-23-209"
},
{
"db": "ZDI",
"id": "ZDI-23-212"
},
{
"db": "VULMON",
"id": "CVE-2021-43336"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-007492"
},
{
"db": "NVD",
"id": "CVE-2021-43336"
},
{
"db": "CNNVD",
"id": "CNNVD-202111-1217"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-22-334"
},
{
"db": "ZDI",
"id": "ZDI-23-127"
},
{
"db": "ZDI",
"id": "ZDI-23-126"
},
{
"db": "ZDI",
"id": "ZDI-23-125"
},
{
"db": "ZDI",
"id": "ZDI-23-210"
},
{
"db": "ZDI",
"id": "ZDI-23-209"
},
{
"db": "ZDI",
"id": "ZDI-23-212"
},
{
"db": "VULMON",
"id": "CVE-2021-43336"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-007492"
},
{
"db": "NVD",
"id": "CVE-2021-43336"
},
{
"db": "CNNVD",
"id": "CNNVD-202111-1217"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-02-15T00:00:00",
"db": "ZDI",
"id": "ZDI-22-334"
},
{
"date": "2023-02-09T00:00:00",
"db": "ZDI",
"id": "ZDI-23-127"
},
{
"date": "2023-02-09T00:00:00",
"db": "ZDI",
"id": "ZDI-23-126"
},
{
"date": "2023-02-09T00:00:00",
"db": "ZDI",
"id": "ZDI-23-125"
},
{
"date": "2023-03-01T00:00:00",
"db": "ZDI",
"id": "ZDI-23-210"
},
{
"date": "2023-03-01T00:00:00",
"db": "ZDI",
"id": "ZDI-23-209"
},
{
"date": "2023-02-09T00:00:00",
"db": "ZDI",
"id": "ZDI-23-212"
},
{
"date": "2021-11-14T00:00:00",
"db": "VULMON",
"id": "CVE-2021-43336"
},
{
"date": "2022-02-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-007492"
},
{
"date": "2021-11-14T21:15:08.263000",
"db": "NVD",
"id": "CVE-2021-43336"
},
{
"date": "2021-11-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202111-1217"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-02-15T00:00:00",
"db": "ZDI",
"id": "ZDI-22-334"
},
{
"date": "2023-02-09T00:00:00",
"db": "ZDI",
"id": "ZDI-23-127"
},
{
"date": "2023-02-09T00:00:00",
"db": "ZDI",
"id": "ZDI-23-126"
},
{
"date": "2023-02-09T00:00:00",
"db": "ZDI",
"id": "ZDI-23-125"
},
{
"date": "2023-03-01T00:00:00",
"db": "ZDI",
"id": "ZDI-23-210"
},
{
"date": "2023-03-01T00:00:00",
"db": "ZDI",
"id": "ZDI-23-209"
},
{
"date": "2023-03-06T00:00:00",
"db": "ZDI",
"id": "ZDI-23-212"
},
{
"date": "2023-02-24T00:00:00",
"db": "VULMON",
"id": "CVE-2021-43336"
},
{
"date": "2023-02-17T02:09:00",
"db": "JVNDB",
"id": "JVNDB-2021-007492"
},
{
"date": "2023-02-24T15:53:38.813000",
"db": "NVD",
"id": "CVE-2021-43336"
},
{
"date": "2023-02-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202111-1217"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202111-1217"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Open Design Alliance (ODA) Drawing SDK DXF File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability",
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-127"
},
{
"db": "ZDI",
"id": "ZDI-23-126"
}
],
"trust": 1.4
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202111-1217"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.